First Breath nCPAP The complete nCPAP system Non-invasive respiratory support
Inspiration Healthcare First Breath nCPAP The complete nCPAP system The First Breath nCPAP system is the next step in neonatal non-invasive support. The First Breath nCPAP Generator builds on the experience of the past to allow caregivers a cost-effective solution for supporting premature and sick babies. Many pre-term babies will require respiratory support once they are born. The nCPAP generator can help early extubation and weaning from ventilators and prevent babies needing further ventilation. The First Breath nCPAP Generator consists of a nCPAP generator that benefits from established fluidic principles to provide non-invasive respiratory support to the neonate, along with circuits, headgear, bonnets, masks and prongs to facilitate ease of use. Novel fixation system ensures Complete system including Single point of fixation nCPAP Generator patient comfort and ease of use prongs and mask aids alignment • Proven fluidic technology • Reduces work of breathing • Compatible with most nCPAP drivers • Complete system including; prongs, masks, headgear, bonnets and circuits • Maintains a constant positive pressure • Follows a known relationship between flow and pressure • Single tube for ease of attachment and better alignment • Increased patient comfort • New headgear – simple to use, reduces set-up time inspiration-healthcare.com
First Breath Circuits System Complete respiratory care nCPAP Headgear Attachment block Adjustable length • A vailable in five sizes Single tube • A djusts to the perfect fit Adjustable • F ast and reliable fit Nasal prong width • Anti-slip for stable and secure fixing • Enables access to scalp • Single point of fixation aids alignment • A ttachment block transfers weight from nasal area • S oft biocompatible materials • Increased patient comfort Adjustable Anti-slip straps Established Fluidic Principles Fluidic flip principle 8 Expiratory 7 limb 6 nCPAP cmH2O 5 Infant Nasal 4 Connection 3 2 Chamber 1 0 Inspiratory Inlet 0 1 2 3 4 5 6 7 8 9 10 11 Fresh gas flow l/min +/–10%
Inspiration Healthcare First Breath Breathing Circuits Complete neonatal care First Breath range of breathing circuits ensures the patient receives optimally heated and humidified gases. The circuits are suitable for conventional ET ventilation, oxygen therapy and non-invasive ventilation in single-limb and dual-limb modes. Each circuit is single patient use and can be adapted easily to meet the needs of the patient. Performance and Versatility The First Breath Breathing Circuits range ensures that any performance and cost requirements can be met, without compromising on patient care. A number of comprehensive features make our circuits ideal for the modern Neonatal Intensive Care unit and provide unmatched versatility. Flexible 360° swivel action Options with and without Connector pack offers a for easy positioning humidification chamber range of therapies inspiration-healthcare.com
First Breath Circuits System First Breath Circuits Key Features • Nitric oxide ports available in the chamber output connection – one less adaptor required • Additional limb for positioning the temperature probe outside the incubator or as close to the patient when using an open cot • V entilation circuits have swivel manifolds for easier positioning close to the patient and to offset the weight of the tube, reducing the chances of inadvertent extubation • Spiral heated wire, heats the tube evenly to reduce condensation and deliver optimal humidification to the patient • Option for Connector Pack means that the breathing circuits can be used for a number of Therapies (single/dual NIV, High Flow) and cover all ventilation modes • C an fit a number of popular ventilators (Acutronic, Drager, SLE) • O ption for humidification chamber to be in the pack or sold separately • C lover leaf adaptor for the humidifier heated wire adaptor • W ith or without proximal airway tube, depending on the ventilator model First Breath range of breathing circuits Single Heated non-invasive circuit Dual Heated Single Heated ventilation ventilation circuit circuit with Watertrap
Inspiration Healthcare Respiratory Humidifier and Autofeed Chamber First Breath Humidification System The Respiratory Humidifier delivers optimal levels of humidity and is fully compatible with our breathing circuits, humidification chambers and electrical adapter leads. It can be used on neonatal, paediatric and adult patients in the intensive care areas. Our humidifiers include a dual temperature probe, dual heater adapter and reusable circuit adaptor as standard. Key Features • O ne button control, simple, convenient • Large and bright LCD display with night viewing • Dynamic control of temperature and humidity • Continuous data record with instant convenient checking • Analogue alarm system, intuitive, fast error processing • Simple and easy heater adapter to prevent connection errors • Invasive and non-invasive modes
First Breath Circuits System Ordering Information Generator and Circuits (Cases of 10 unless otherwise stated) Single Heated Breathing Circuits with Watertrap (Cases of 10 unless otherwise stated) Inspire nCPAP™ Generator complete IHC600/10 with nasal prongs Neonatal Single Heated Breathing Circuit with Water Trap C4202 (Case of 20) Inspire nCPAP™ Generator only IHC616/10 Inspire nCPAP™ Silencer (Case of 20) IHC602/20 Neonatal Single Heated Breathing Circuit with Water Trap C4203 and Autofeed Chamber C4601 Masks (Cases of 10) IHC609/10 C4125 Inspire nCPAP™ Mask Small IHC610/10 Neonatal Single Heated Breathing Circuit with Inspire nCPAP™ Mask Medium Water Trap and Universal Connector Pack (Case of 20) C4225 Inspire nCPAP™ Mask Large IHC611/10 Neonatal Single Heated Breathing Circuit with Water Trap, C4210 Universal Connector Pack and Autofeed Chamber Inspire nCPAP™ Mask Extra Large IHC612/10 C4211 wNeonatal Single Heated Breathing Circuit with Prongs (Case of 10) Water Trap and Flow Restrictor (SLE2000) (Case of 20) C4215 Inspire nCPAP™ Nasal Prong Extra Small IHC604/10 Neonatal Single Heated Breathing Circuit with Water Trap, Flow Restrictor (SLE2000) and Autofeed Chamber Inspire nCPAP™ Nasal Prong Small IHC605/10 Inspire nCPAP™ Nasal Prong Medium IHC606/10 Neonatal Single Heated Breathing Circuit with Water Trap Inspire nCPAP™ Nasal Prong Large IHC607/10 and Flow Restrictor (SLE5000/6000) (Case of 20) Bonnets (Case of 10) Neonatal Single Heated Breathing Circuit with Water Trap, C4216 Inspire nCPAP™ White Bonnet 16-18 cm Flow Restrictor (SLE5000/6000) and Autofeed Chamber Inspire nCPAP™ Grey Bonnet 18-20 cm IHBWH000/10 Neonatal Single Heated Breathing Circuit with Water Trap C4206 IHBGY00/10 and Soft Connectors (Babylog 8000) (Case of 20) Inspire nCPAP™ Pink Bonnet 20-22 cm IHBPK0/10) Neonatal Single Heated Breathing Circuit with Water Trap, C4207 Soft Connectors (Babylog 8000) and Autofeed Chamber Inspire nCPAP™ Brown Bonnet 22-24 cm IHBBR1/10) Autofeed Humidification Chamber (Case of 12) VX226 Inspire nCPAP™ Yellow Bonnet 24-26 cm IHBYE2/10 Dual Heated Breathing Circuits (Cases of 10 unless otherwise stated) Inspire nCPAP™ Blue Bonnet 26-28 cm IHBBL3/10 Inspire nCPAP™ Gold Bonnet 28-30 cm IHBGO4/10 Neonatal Dual Heated Breathing Circuit (Case of 20) C4200 Inspire nCPAP™ Green Bonnet 30-32 cm IHBGR5/10 Neonatal Dual Heated Breathing Circuit Pack C4201 Inspire nCPAP™ Burgundy Bonnet 32-34 cm IHBBU6/10 and Autofeed Chamber Inspire nCPAP™ Orange Bonnet 34-36 cm IHBOR7/10 Inspire nCPAP™ Dark Green Bonnet 36-38 cm IHBDG8/10 Neonatal Dual Heated Breathing Circuit with C4135 Inspire nCPAP™ Navy Bonnet 38-40 cm IHBNA9/10 Universal Connector Pack (Case of 20) Neonatal Dual Heated Breathing Circuit with C4235 Universal Connector Pack and Autofeed Chamber Circuits Neonatal Dual Heated Breathing Circuit with C4213 Flow Restrictor (SLE2000) (Case of 20) For a full range of Inspire circuits please see our First Breath Circuit brochure. Single Heated Circuits (Cases of 10 unless otherwise stated) Neonatal Dual Heated Breathing Circuit with C4214 Flow Restrictor (SLE2000) and Autofeed Chamber Neonatal Single Heated Breathing Circuit with C4204 Twin Connector (Case of 20) Neonatal Dual Heated Breathing Circuit with C4217 Flow Restrictor (SLE5000/6000) (Case of 20) Neonatal Single Heated Breathing Circuit with C4205 Twin Connector and Autofeed Chamber Neonatal Dual Heated Breathing Circuit with C4218 Flow Restrictor (SLE5000/6000) and Autofeed Chamber Neonatal Single Heated Breathing Circuit (Case of 20) C4302 Neonatal Dual Heated Breathing Circuit with C4219 Neonatal Single Heated Breathing Circuit and C4303 Soft Connector (Babylog 8000) (Case of 20) Autofeed Chamber Neonatal Dual Heated Breathing Circuit with C4220 Neonatal Single Heated Breathing Circuit with C4244 Soft Connector (Babylog 8000) and Autofeed Chamber Twin Connector and Fabian Connecting Tube (Case of 20) Neonatal Single Heated Breathing Circuit C4124 Neonatal Single Heated Breathing Circuit with Twin C4245 with Universal Connector Pack (Case of 20) Connector, Fabian Connecting Tube and Autofeed Chamber Neonatal Single Heated Breathing Circuit with C4224 Universal Connector Pack and Autofeed Chamber Neonatal Single Heated Breathing Circuit with C4342 Fabian Connecting Tube (Case of 20) Autofeed Humidification Chamber (Case of 12) VX226 Neonatal Single Heated Breathing Circuit with C4343 Fabian Connecting and Autofeed Chamber Respiratory Humidifier and Autofeed Chamber Neonatal Nasal Cannula Single Heated Breathing Circuit C4330 Respiratory Humidifier (UK Plug) (1) VX8500 Connecting Tube (Case of 20) Respiratory Humidifier (Euro Plug) (1) VX8501 Neonatal Nasal Cannula Single Heated Breathing Circuit C4331 Humidifier/Temperature Sensor VXBTMP and Autofeed Chamber Heater Wire Adaptor for Dual/Single Heated Circuit Neonatal Single Heated Breathing Circuit with Universal C4124 (Case of 6) VXBHWD Connector Pack (Case of 20) Heater Wire Adaptor for Reusable Heated Circuit Neonatal Single Heated Breathing Circuit with Universal C4224 (Case of 6) VXBHWR Connector Pack and Autofeed Chamber Autofeed Humidification Chamber (Case of 12) VX226 Autofeed Humidification Chamber (Case of 12) VX226 Fabian Connecting Tube C4326
Inspiration Healthcare First Breath Circuits System Technical Description and Performance Circuits Technical Description Flow resistance ≤ 0.74 cmH2O/l/min @ 2.5 l/min Leakage 30 ml/min @ (60±3) cmH2O Compliance ≤ 1.5 ml/cmH2O @ (60±3) cmH2O Circuit length 1.6 m Inside diameter of tube 10.4 mm Humidifier Performance Ratings 110-127V~, 50/60Hz, 20VA, Heater Wire: 24VDC, 80VA(Max) 210-140V~, 50/60Hz, 330VA, Heater plate cut-off temperature 118±7˚C Patient side temperature range Invasive mode: 35-40˚C, Default: 39˚C Non-invasive mode: 30-37˚C, Default: 34˚C Probe detection range 0-150˚C, Accuracy: ±0.5˚C (in 20-45˚C temperature range) Machine noise ≤50db Humidifier Chamber Performance Type Disposable single patient use Fill water mode Autofeed Compressible volume (empty) 440 ml Compressible volume (full) 260 ml Maximum water capacity 180 ml Maximum peak flow 90 L/Min Resistance (cmH2O) <1 cmH2O @ 60L/min Compliance (empty) <0.70 ml/cmH2O The details given in this brochure are correct at time of going to press. The photo used on the front of this brochure is a retouched representation of the product. The images used are for illustration purposes only and may differ from the actual product. The company reserves the right to improve the products shown. Not all accessories are available in all markets. Please contact your local Inspiration Healthcare representative for more information. 000-000(1) 2020-00 Distributed by Inspiration Healthcare Limited 2 Satellite Business Village, Fleming Way, Crawley, West Sussex, RH10 9NE United Kingdom T +44 (0)1455 840 555 F +44 (0)1455 841 464 E [email protected] W inspiration-healthcare.com
Search
Read the Text Version
- 1 - 8
Pages: