Home Explore OmniCure® UV LED Curing Products

OmniCure® UV LED Curing Products

Published by kathryn.barbe, 2016-05-20 10:33:21

Description: OmniCure innovative light curing solutions provide leading manufacturers worldwide with the most advanced, simple-to-use and reliable UV curing technology. Leveraging over 30 years of industry expertise, OmniCure delivers faster and more consistent process curing results, ensuring customers benefit from the highest quality, production, and efficiency. The OmniCure product family includes both lamp and UV LED solutions to best meet the challenging demands of spot, small and wide area curing applications.

Keywords: UV LED Curing systems,LED Spot curing,Flood lamps,UV LED air-cooled lamps,OEM Supplier

Search

Read the Text Version

OmniCure AC Series Advanced, Air-Cooled UV LED Area Curing Solutions for Adhesives, Coatings and Inks Bringing high power, superior performance and maximum flexibility to best fit your UV application needs. Enhanced throughput and performance through high UV output power Flexibility and simplified integration via superior irradiance performance Rapid and efficient curing from advanced front-end custom optics Consistent results with exceptional uniformity in UV outputwww.excelitas.com

OmniCure AC275 and AC2110Compact UV LED CuringSystems for Inks, Coatingsand AdhesivesCompact air-cooled UV LED design forease of integrationOutstanding optical performance to providemaximum irradianceSuperior uniformity with the ability to adjoinmultiple UV LED headsExceptional process control for repeatablecuring results www.excelitas.com

OmniCure AC550 / AC550P and AC575 / AC575PHigh Power, Small AreaUV LED Curing System forAdhesives, Coatings and InksExceptional irradiance performance foraccommodating different working distancesSuperior uniformity to maximize the addressablecuring areaFlexibility with control for repeatable curing resultsEase of integration via compact, air-cooled LED design www.excelitas.com

OmniCure AC450 and AC475Small Area UV LEDCuring Systems forAdhesives, Coatings and InksExceptional irradiance performance to accommodatedifferent working distancesSuperior uniformity to maximize the addressablecuring areaFlexibility with control for repeatable curing resultsCompact, air-cooled LED design for ease of integration www.excelitas.com

OmniCure AC8150/P, AC8225/P and AC8300Large Area UV LEDCuring Systems forAdhesives, Coatings and InksOutstanding optical performance to providehigh irradiance at varying working distancesSuperior uniformity with the ability to adjoinmultiple UV LED headsExceptional process control to achieve repeatablecuring resultsCompact air-cooled UV LED design forease of integration www.excelitas.com

OmniCure AC9150/P, AC9225/P, AC9300/PHigh Power UV LEDCuring Systems forAdhesives, Coatings and InksOutstanding optical performance to providehigh irradiance at varying working distancesSuperior uniformity with the ability to adjoinmultiple UV LED headsExceptional process control to achieve repeatablecuring resultsCompact air-cooled UV LED design forease of integration www.excelitas.com

OmniCure AC7150 and AC7300Large Area UV LED CuringSystems for Adhesive andCoating ApplicationsIdeal for adhesive and coating applications such as displays,touch panels, thin films and fibersExceptional irradiance performance to accommodate differentworking distancesSuperior uniformity to maximize the addressable curing areaFlexibility with control for repeatable curing resultsCompact, air-cooled LED design for ease of integration www.excelitas.com

OmniCure AC8225-FAir-cooled UV LEDSolution for Fiber CuringApplicationsCustom optical design to provide high peak irradiance atspecific working distancesExceptional cost savings from reduced electricityconsumption and long LED lifetimePatented LED control technology for superior uniformityCompact air-cooled UV LED design for ease of integration www.excelitas.com

OmniCure CV300Benchtop ConveyorSystemComplementary to the OmniCure® AC Series high power UV LED areacuring systems, and is suitable for production, laboratory, and researchand development applicationsVersatile system designed to handle substrates up to 310 mm (12.2”)wide with an effective curing area of up to 300 mm (12”)Flexible mounting mechanism to support use of a single or multiplecuring systemsAdjustable platform height to accommodate a variety of parts andworking distances www.excelitas.com

OmniCure LX500Ultra-Compact UV LEDSpot Curing System for aConsistent, RepeatableCuring ProcessOutstanding optical stability via Intelli-LampLED technologyExceptionally high peak irradiance forincreased curing efficiencyCalibration utility to maintain long term stabilityof UV lightUnparalleled process control with StepCure® 2.0Programming and data logging in real time viaa Micro SD www.excelitas.com

OmniCure PLC2000Intelligent External PLC Controllerfor AC Series UV LEDCuring SystemsComplimentary accessory for the OmniCure® AC Series UVLED curing systems to provide a fully integrated solutionIntelligent digital control of the UV curing solution to ensurea repeatable UV processDynamic adjustment of settings with system information anderror monitoringFlexible operation of the OmniCure PLC2000 either locally orremotely through an automated systemQuick set-up, easy integration, and intuitive control features www.excelitas.com

OmniCure S Series UV Curing SolutionsSetting the Standardfor PrecisionUV Spot Curing www.excelitas.com

OmniCure SC Series Power Supply ControllerOffering Greatest Flexibilityand Simplicity for UV CuringApplicationsTailored for integration with AC Series UV LED curing productsCompatible across entire AC Series systems, with common DC powerconnector interface and voltage specificationsScalable and compact form factor that enables simplified integrationand short commissioning timeFlexible design allows for customization and selection of the best SCpower supply controller to meet curing needsSeamless integration into standard industrial equipment racking withthe SC0750, SC1000, SC2000 and SC3000 www.excelitas.com

OmniCure LX400+The Most Advanced, Versatileand Easy-to-use UV LED SpotCuring SystemFast curing time and high power efficiencyFlexibility with a wide range of UV curable adhesivesMaximum versatility for curing processesReduction in UV manufacturing costsEase of use with a single solution for multiple applicationsLow cost of set up and ownership www.excelitas.com

OmniCure R2000 RadiometerYour Technology Advantage fora Repeatable UV ProcessAccurate radiometry is essential to maintaining a calibrated and repeatableUV curing process suitable for consistent, high-quality production. TheOmniCure® R2000 Radiometer is the most advanced and accurate toolfor measuring irradiance or power from your UV Spot Curing System.The portable OmniCure R2000 can be combined withthe OmniCure S2000 system to provide a complete curingstation with unmatched control and repeatability.Maintain process control and save setup time by calibratingmultiple systems with a preferred irradiance set pointAchieve accurate wideband measurements with ourproprietary detector systemsVirtually eliminate beam profile dependance andsignificantly improve measurement accuracy through ourproprietary optical interfaceStore data and communicate with PC software fordownloadingReady for use with additional custom accessories such asthe Cure Ring and the Cure Site Detectors www.excelitas.com

Maximum Flexibility and Process ControlOmniCure R2000 RadiometerExpanding Your OptionsProximity Adaptor Lamp Cure Ring Cure Site Output Adaptor Detector DetectorThe proximity adaptor allows theuser to obtain accurate application- The lamp output adaptor is a rigid When used in conjunction with the When used in combination withspecific power or irradiance adaptor that interfaces the curing OmniCure R2000 Radiometer, the the OmniCure R2000 Radiometer,measurements in flood geometry. unit and light source to allow Cure Ring Detector measures the Cure Site Detector measuresMeasurements are done by placing direct measurements of the lamp output power from the Cure Ring output power of a Light Guide orthe emitting end of the light power. This optical accessory is very directly at the cure site, ensuring a optical accessory directly at thedirectly over the top of the important for system maintenance highly repeatable process. cure site. This provides accurateproximity adaptor, inserted into the as it can be used to determine if the data for energy calculations,OmniCure® R2000 Radiometer. Light Guide requires replacement enabling the user to control the due to degradation. curing process more accurately.DESCRIPTION 250 nm - 1µm (with suitable calibration)Wavelength Range Power: 1 mW-12 W Irradiance: 5 mW/cm2-60 W/cm2 (with 5 mm Light Guide)Maximum RangeResolution Power: 1 mW Irradiance: 5 mW/cm2 (with 5 mm Light Guide)AccuracyAuto-ranging +/- 5% typical; +/- 10% maximumBatteryBattery Life Power: 1-990 mW; 1.0-12.00 W Irradiance: 5-990 mW/cm2; 1.0-60 W/cm2Functions 3.6V LiCertification 2 years, typical (intermittent use) Irradiance Measurement, Power Measurement, Automatic Light Guide Detection, Relative Mode, OmniCure Calibration, Store Data Points, External Input, On Button, Auto Off, Calibration Due Message CE marked; complies with IEC, Canadian and US Standards, RoHS compliantGENERAL SPECIFICATIONS 7 1/2” x 4 3/8” x 2” (19.0 cm x 11.1 cm x 5.0 cm) 1 lb (450 g)Dimensions (L x W x H) 1 yearWeightWarranty 1Calibration of the OmniCure® R2000 Radiometer is recommended every twelve months. Contact Excelitas Technologies for further information. To learn more about OmniCure UV curing solutions, please visit www.excelitas.com/omnicure. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014

Utilizing advanced UV LED technology, the OmniCure® LX400+ LED spot curing system has been specially designed to reduce UV bonding manufacturing costs through fastercuring times, higher power efficiency and superiorcontrol with monitoring capabilities.The LX400+ system offers a robust and intuitive user interface with quick configurationcapabilities including ready to use timer, power level and head temperature display modes, as wellas a durable and reliable “Start/Stop” activation button.Sequential exposure of channels 1, 2, 3 and 4 with the channel configuration mode FP6Operator Trigger CH1 CH2 CH3 CH4 Exposure Exposure Exposure Exposure Setting #1 Setting #2 Setting #3 Setting #4FEATURES BENEFITSLatest UV LED technology to provide high irradiance at different Reduction in UV manufacturing costs with faster curing times and higherwavelengths: power efficiency while supporting a wide range of UV cured adhesives• 9,500mW/cm2 (typical) at 365nm• 12,400mW/cm2 (typical) at 385nm Maximum flexibility for manufacturing setups where single or multiple foot• 9,000mW/cm2 (typical) at 400nm pedals are needed to control a number of curing stations simultaneouslyFull Control of up to four UV LED heads simultaneously or independently Repeatability in UV curing processes for consistent and highest product qualityPrecise monitoring and regulation of UV light exposure time (+/- 0.1 Maximum UV LED head power efficiency, long term reliabilityseconds) and intensity level (+/- 1%) of up to four different UV LED heads and guaranteed lifetime Optimization of UV LED head output power efficiencyHighly efficient and Intelligent UV LED heads with extra cooling Ease of use while eliminating the need for an external control unitcapability and patented Intelli-Lamp® technologyUV LED head temperature on display in real timeCustomized multi-phase curing processes directly from the LX400+ controller

Overview of 55 mmAccessories Available 12 mmInterchangeable/Replaceable Focusing Lens Options 130 mm 12 mmUV LED HEADSThe LED Heads have been uniquely designed for highly efficient cooling to maximize continuousoperation without over-heating. This will minimize costly downtime and extend the life of theLED Heads, resulting in low cost of ownership and convenience that manufacturers can rely on.Due to its superior design, when properly clamped, the head may be used continuously whileremaining cool. FOCUSING LENSES OmniCure UV LED Heads use replaceable focusing lenses that offer the flexibility essential to meet the spot size and irradiance level required for a specific application. Beam profiles for the OmniCure 365nm UV LED MAX heads with the 3mm, 6mm and 8mm lenses are illustrated below. Additional beam profiles and technical information are available on the OmniCure website (www.excelitas.com/omnicure). With a 3mm Focusing Lens With a 6mm Focusing Lens With a 8mm Focusing LensOptimized for a working distance of 9±1mm Optimized for a working distance of 18±1mm Optimized for a working distance of 25±1mm11000 4000 2000 Working 1800 Distance: DWiostraknincge: 1600 9mm 1400 10mm 10000 1200 15mm 1000 20mmLED Head and Focusing Lens Specifications9000 25mm 3500 Working 30mm Distance: 40mm 50mm 10mm 15mm 17.5mm 20mm 3000 20mm8000Irradiance (mW/cm2) Irradiance (mW/cm2)25mm7000 Irradiance (mW/cm2)25mm250030mm 30mm 40mm6000 200050004000 1500 8003000 1000 6002000 5001000 4000 0 200 -3 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 2.5 3 -5 -4 -3 -2 -1 0 1 2 3 4 5 0 Radius of Irradiation Area (mm) Radius of Irradiation Area (mm) -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 Radius of Irradiation Area (mm)UV LED LIGHT METERThe OmniCure LED Light Meter can measure power and irradianceby selecting a specific wavelength on the meter that corresponds tothe wavelength of the UV LED source. This enables manufacturersto achieve greater accuracy with ease of use while maintainingreliable and controlled UV processes. (NIST, NRC Traceable) www.excelitas.com

USER INTERFACE GENERAL SPECIFICATIONSUV LED Heads Up to 4 interchangeable individual headsLED Indicators Mode and Up/Down buttons to control the display modeMode Control Programmable trigger mode:Exposure Time Control • Countdown Mode: Range programmable from 999.9s to 0.1s, in 0.1s intervals • Count Up Mode: User controlled timing via the front panel or foot pedalsIntensity Level ControlHead Actuation Button Programmable trigger mode:Foot Pedal Ports • Countdown Mode: Range programmable from 999.9s to 0.1s, in 0.1s intervalsLED Indicators • Count Up Mode: User controlled timing via the front panel or foot pedalsKey SwitchExternal Unit Controller Input 15%-100% (with 1% increments)(PLC Port)UV LED Head Over Temperature Control start or stop of UV LED emissionProtectionController Dimensions and Weight 4 foot pedal ports to control start or stop of the LED Emission Indicates Timer Control, Level, Trigger Mode and UV Emission (UV ON) Turn on/off controller PLC port allowing external control and monitoring: Start/stop, intensity level selection, lock front panel interface and timer mode selection Cutoff temperatures 365 nm MAX heads: 65°C, 385 nm MAX heads: 65°C, 400 nm heads: 60°C W x L x H : 7.55” (191.77 mm) x 6.6” (167.64 mm) x 2.9” (73.66 mm) 2.15 lbs (0.98 kg)PLC Connector Pin-Outs VCC+ Typical Output Signal Circuitry VCC+ 7.55 inches (191.77mm) 6.6 inches (167.64mm) Internal to Unit Active LowTypical Output Signal Circuitry Con guration Power Consumption (W) Internal to Unit Connections External to Unit Power Consumption (W) Connections 2.9 inches (73.66mm) External to Unit Active High Con guration Front View Back ViewActive Low-Signal Circuit Configuration Active High-Signal Circuit Configuration OmniCuLrXe®4L0XL04X+0400E+0n+vesErnTgyeyprgicEyaflEfiUfficVcieiAenrncccyLyamp Systems OmniCure® LX400+ vs Typical UV Arc Lamp SystemsFoot Pedal Channel Control 500 CH1 CH2 CH3 CH4 450W FP4 FP4 500 440500W 300W FP4FP1 Mode FP1 FP2 FP3 400 300FP2 ModeFP3 Mode 300 200 300W FP1 Controls FP3 100 72W CH 1, 2 Simultaneously 200 0 FP1 Controls CH 1, 2, 3 Simultaneously 100 200W Arc lamp 100W Arc lamp OmniCu7r2eW® LX400+ System (typical) System (typical) UV LED SystemFP4 Mode FP1 Controls All Channels Simultaneously LX0400+ offers energy savings and is eco-friendly. OmniCure LX400+FP5 Mode UV L2E0D0cWurinAgrscysltaemmpconsum1es0a0bWoutA7r5c%lalemsspenergOy mthanniCa utyrpeic®al LX400+FP6 Mode UV Sarycsltaemmp c(utryinpgicsyaslt)em. System (typical) UV LED System FP1 Controls FP3 Controls CH 1, 2 Simultaneously CH 3, 4 Simultaneously FP1 Sequentially Exposes CH 1,2,3,4 OmniCure LX Series Controller Part Number OmniCure LX400+ Controller 010-00243R To learn more about OmniCure UV curing solutions, please visit www.excelitas.com/omnicure. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014

Features and Benefits Mechanical Drawings SC0650 SC0650 Single-head Solution Simple and cost-effective for small Measurements: area applications mm (in) Flexible Installation Options Easy installation in any orientation with 304.61 minimal additional hardware required (11.99) Standard Connection Consistent across the entire 83.0 (13.357.08) 2X(38.236.08) 2X 120.0 4X Ø 6.0 THRU on All OmniCure® OmniCure AC Series product range (3.27) (4.724) (.236) AC Series Products to minimize inventory 2X 7.0 5X 10.0 (.276) (.394) Compact and Lightweight Adaptable to most environments (8.3.015) TYP Integrated, User- Allows installation in environments 5X 170.0 4X Ø 10.0 2X 170.0 139.0 190.0 Serviceable Air Filter without additional dust-screening (6.693) (.394) (6.693) (5.47) (7.48) methods 4X M5 THRU SC0750, SC1000, SC2000, SC3000 3X 58.0 3X(167.609.30) 43.0 (2.283) 292.3 (1.693) Professional Easy integration into industrial (11.51) 2X Grade Solution environments with standardized enclosure, mounting and minimal 4X Ø (.263.06) maintenance Standard Connection Suitable for use across the entire 313.7 on All OmniCure OmniCure AC Series product range (12.35) AC Series Products to minimize inventory Conveyor Compatible Standardized mount spacing ensures SC0750, SC1000, SC2000 hassle-free installation in OmniCure CV300 conveyor Measurements: mm (in) Compact Form Factor High power-density, scalable solution 43.9 444.7 with multiple power connectors for large (1.73) (17.51) area curing 431.8 (17.00) Integrated Circuit Breaker Resettable protection provides guaranteed isolation for maintenance or in the event of an electrical fault 327.3 340.5 (12.88) (13.40) 330.4 (13.01) 347.74 (13.69) Technical Specifications SC0650 SC0750 SC1000 SC2000 SC3000 10-40 ºC Operating Temperature 2X 6.35 2X 462.92 2X 6(..2355) Range (.25) (18.22) Dimensions* (L x W x H) 293 x 341 x 445 x 44 mm 341 x 445 4X 31.75 Ø 6.35 TYP x 67 mm (1.25) (.25) Weight 190 x 83 489.0 6.5 kg 4X 6.35 (19.25) Input Voltage mm (14.3 lbs) (.25) 200-240 VAC 50/60 2.0 kg 3.9 kg Hz SC3000 (4.5 lbs) (8.6 lbs) 13-9.6 A 15.6-13 A Measurements: 100-240 VAC 50/60 Hz 16 A mm (in) Max. AC 7.5-3.1 A 9-4.3 A 12-6.5 A 2000 W 2800 W 67.0 490.15 Input Current (2.64) (19.30) Protection 8A 10 A 13 A Rating Fuse 650 W Circuit Breaker 343.37 Max. DC (13.52) Power 750 W 1000 W 330.16 337.87 (13.00) (13.30) 347.74 Operating (13.69) Voltage 48 V DC ± 1 V Max. DC Current 13.5 A 15.7 A 21 A 41.5 A 58.3 A 4 # of DC 12 4x 6.35 4x 6.35 44.45 Output (.25) (.25) (1.75) Connectors 4x Certifications 4x 44.45 462.9 6.35 (1.75) (18.23) (.25) 9.85 4x 4x CE, RoHS, WEEE 4x (.39)*Not including mounting brackets. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014

Power • Precision • Control • RepeatabilityThe Preferred Choice of stronger, faster bonds - resulting in improved quality, rapidPrecision Manufacturers production and reduced manufacturing costs for a wide range of applications.Manufacturers in advanced technology sectors around the worldincreasingly rely on the advantages that light-based, spot curing System Versatility – Lean Manufacturingbrings to precision assembly. The use of UV/visible light cureadhesives has become a vital assembly technique due to their OmniCure precision technology is effective in both fullyrapid processing, on-demand nature, ease of automation and automated assembly lines and semi-automatic applications,solvent free bonding. making it suitable for every type of manufacturer. The ability to calibrate equipment, and accurately set the irradiance level andA Proven Track Record duration of exposure provides the process control necessary to efficiently maximize yields.Founded in 1984, OmniCure® delivers UV spot curing solutions tomore than 70 countries worldwide and is recognized as the most Calibrated Outputadvanced in their field. Wherever rapid processing, cure-on-demand, ease of automation, lower energy usage and solvent An integral part of the OmniCure curing system is the OmniCurefree bonding is required, OmniCure is the obvious choice. R2000 Radiometer. Used to both measure irradiance and calibrate the S2000 and S1500 to the set irradiance levels, thisPrecise and Reliable Curing advanced tool greatly enhances the precision and reliability of the OmniCure Series systems.Whether manufacturing medical devices for the human body,electronics industry assembly or other industrial components, Experience Countsthere is no room for product failure. The OmniCure Series ofcuring systems are trusted by critical industries everywhere to With UV applications expertise built over the years since 1984,provide quality adhesion, time and time again. our global Sales & Support footprint provides all the knowledge you need to help solve your applications needs.Substrate Versatility Meets Regulatory StandardsPartnered with light cure adhesives, OmniCure’s leading-edgetechnology is used with a broad range of substrates to deliver OmniCure technology meets all regulatory CE, UL, CSA and ETC requirements. The OmniCure S2000 and S1500 are is also RoHSTypical Applications compliant.Medical Optoelectronics Electronic Assembly Optics & General AssemblyNeedle Assembly Fiber Optic Components Cell Phone AssemblyCatheter Assembly Optical Data Storage Micro-Speaker Assembly Optical Lens AssemblyCannula Assembly Digital Projectors LCD/LCM Stereolithography (SLA)Tubing and Connectors Optical Sensors Automotive Electronics Sealing and CoatingEndoscope Assembly Lasers Smart Cards Analytical InstrumentationInsulin Pens Compact Camera Modules High Density Drives (HDD)Blood Oxygenators Bluetooth Headsets Pick and Place ‘Flat Topping’

The recognized global leader in UV curing systems forprecision assembly with light-cured adhesivesPatented Intelli-Lamp Technology...the heart of all OmniCure systems Guaranteed Long Life The OmniCure S2000 and the OmniCure S1500 systems with Intelli-Lamp® technology Maximize Lamp Output have a guaranteed 2000-hour lifetime and up to 4000-hour typical lifetime.Automatic Lamp Hour Tracking Snap-in insertion and built-in reflector optimize the light energy coupled Broad Spectral Output to the light guide without operator alignment or focusing. Always Connected The Intelli-Lamp technology automatically maintains the lamp hours directly Hot-Strike Prevention on the lamp to facilitate activation of lamp warranty if required. The broad spectral output across the UV and visible spectrum, make it suitable for a wide range of adhesive/substrate bonding applications. OmniCure systems automatically detect the Intelli-Lamp technology ensuring the benefits without the need for operator intervention. Automatic lamp striking cools and prevents hot-striking to protect lamp life.Proprietary Closed-Loop Irradiance (mW/cm2) Closed-Loop Feedback ComparisonFeedback Elapsed Time (Lamp Hours ON)Automatic Correction to Lamp Intensity Drop-off www.excelitas.comOver time, lamp output decreases, diminishing effective curing. TheOmniCure S2000 Closed-Loop Feedback technology includes an internalintensity sensor to monitor lamp output in real time and adjust the iris toautomatically maintain the irradiance level to within +/-5% of the setpoint, ensuring repeatable and measurable doses of curing energy forincreased yields and quality.A PLC/audible alarm warns when the lamp can nolonger generate the set irradiance level. Now youcan use your lamp until the end of its lifetime,without the requirement to frequently check theirradiance level.Calibration with the OmniCure R2000 Radiometeroffers real time display of irradiance on theOmniCure S2000.• The only system that can be calibrated in real time for NIST accuracy• Ideal for automated or semi-automated environments• Often imitated – never duplicated• Proprietary technology of Excelitas Technologies

The OmniCure S1500 The OmniCure S1500 delivers power, control and reliability in a cost-effective and easy-to-use spot curing system. This UV curing solution offers excellent value for the UV adhesive curing of high-volume, automated manufacturing requirements such as microelectronic and optoelectronic manufacturing applications.Increased Productivity OmniCure S1500 Typical Irradiance*The powerful 200 Watt lamp with patented Intelli-Lamp technology (W/cm2), 5mm LG & 0mm Working Distanceinstalled in the OmniCure S1500 guarantees an amazing 2000-hour lamp life and a typical lamp life of up to 4,000 hours. Faster S1500 R2000curing is achieved with high UVA irradiance of up to 10W/cm2. WithOmniCure’s latest design enhancements to the lamps used in the FILTER (nm) IRRADIANCE (W/cm2)S2000 and S1500, customers benefit from improved robustness 320-500 23that meets its highest quality and performance standards. 400-500 14.5 320-390 7.3Intelligent Operation 365 5.9 250-450 19.1The OmniCure S1500 has a multitude of built-in features that no filter 27.7provide greater control, precision and versatility. Features includean adjustable iris, patented Intelli-Lamp technology, selectable *Measured using an OmniCure R2000 Radiometer.bandpass filters, process alarms, and ‘lock out’ protection, most ofwhich are found only in higher-priced curing systems. The curingsystem can also be programmed and controlled externally from aPLC using the 15-pin I/O ports.Ease-of-UseWith snap-in lamp insertion, finger touch controls, an easy-to-readLED display, process indicators and automatic lamp striking, theOmniCure S1500 is simple to use.

OmniCure S2000The OmniCure S2000 is engineered forhigh-speed automated manufacturing assembly.Building on the core OmniCure technology, the OmniCure S2000has a more powerful 200 Watt lamp with a 2000 hour life guaranteeand typical lifetime up to 4000 hours. The OmniCure S2000 includesproprietary Closed-Loop Feedback technology and the added flexibility of a PC software interfacefor computer-controlled operation. Greater control and with enhanced reliability, the OmniCureS2000 raises the bar for mission critical bonding applications.Faster Shutter Activation Multiple Site Light DeliveryThe OmniCure S2000 is equipped with a fast shutter activation The OmniCure S2000 is ideal for use with multi-legged High Powertime, providing a maximum trigger shutter activation latency Fiber Light Guides to cure multiple sites with a single light source.of only 50ms in PLC mode. Also offered are Single-Legged, Liquid-Filled or Fiber Light Guides to suit most customer needs.Downloadable StepCure® Intelligent AutomationStepCure software has the option to download a customizedmulti-phase cure profile directly to the system. Previously only The OmniCure S2000 is ideal for automated processes, and is easilyavailable while connected to an external Desktop PC, this offers integrated into an automated system, minimizing developmentusers more convenience and greater efficiencies. time. The curing system can be programmed and controlled externally from a PLC, using the 15-pin I/O ports or directly from aIncreased Productivity PC via serial communication. PC software and commands are included with the system.Powerful 200W lamp with patented Intelli-Lamp technology hasa guaranteed life of 2000 hours with up to 4000 hours typical OmniCure S2000 Typical Irradiance*lifetime. Provides fast, even curing with high UVA irradiance of up to10W/cm2. With OmniCure's latest design enhancements to the (W/cm2), 5mm LG & 0mm Working Distancelamps used in the S2000 and S1500, customers benefit fromimproved robustness that meets its highest quality and S2000 R2000performance standards. FILTER IRRADIANCE Closed-Loop Feedback 320-500 24.70 Over time, lamp output decreases, diminishing 400-500 16.55 effective curing. The OmniCure S2000 Closed-Loop 320-390 9.83 Feedback technology includes an internal intensity 365 7.28sensor to monitor lamp output in real time and adjust the iris to 250-450 26.64automatically maintain the irradiance level to within +/-5% of the no filter 37.33set point, ensuring repeatable and measurable doses of curingenergy for increased yields and quality. *Measured using an OmniCure R2000 Radiometer.Online tools are available on the OmniCure website atexcelitas.com/omnicure to determine associated cost savingsusing Closed-Loop Feedback. www.excelitas.com

Shared FeaturesThe following features are found in the OmniCure S1500 and S2000 productsQuiet Fan Adjustable IrisThe noise level of the OmniCure cooling fan has been The OmniCure adjustable iris allows you to select precise irradiancereduced considerably – ideal for long operator work periods. levels to meet the requirements of the specific application. The iris setting is adjustable in 1% increments with a linear relationshipControlled Curing Power between the iris position and the output irradiance, providing exceptional precision for process optimization.The OmniCure Series products offer the ultimate in control,providing unparalleled levels of customization and precision Ease of Use and Process Integrationto leading manufacturers in the most demanding advancedtechnology fields. Built-in UV Sensors and Optical Feedback Snap-in lamp insertion, finger touch controls, LED display, processoffer constant UV intensity for stable curing and high indicators and automatic lamp striking make the OmniCure Seriesbond integrity. simple to use. The flexibility of output and computer controllability of the OmniCure S2000 make it simple to incorporate into complexSelectable Bandpass Filters manufacturing processes.All OmniCure models come equipped with a standard Designed with Safety in Mindheat-cut filter, or they can be ordered with selectable bandpass filters to select and control the wavelength required A built-in sensor automatically detects light guide status, and iffor your specific application. the light guide is missing or improperly inserted, the shutter automatically closes and the status LED will turn red.

R2000 Radiometer The OmniCure R2000 Radiometer is an integral part of the OmniCure curing system. Used to measure irradiance levels and calibrate the S2000 and S1500 to the irradiance set point, it is the most advanced tool of its kind; greatly enhancing manufacturing precision and cure reliability.Cure Ring Radiometer Cure Site Radiometer Lamp Output Adaptor Proximity AdaptorMeasures output power from the Measures the irradiance of a light Allows measurements directly Measures power or irradianceCure Ring directly at the cure site, guide or Optical Accessory directly from the lamp to test the in flood geometry.ensuring a highly repeatable process. at the cure site. integrity of the light guide.Repeatability Through Calibration Proprietary Detector SystemThe OmniCure R2000 Radiometer is the industry standard in Proprietary detector system provides the accurate widebandradiometry – providing several advanced features not found in measurements crucial to maintaining consistent results andcompetitive products. production yield.It is used with the OmniCure S2000 and S1500 systems to set Light Guide Detectionirradiance levels* and calibrate the system from a single referencepoint, providing a complete curing station, and dependable, Automatically detects and identifies the Light Guide diameterrepeatable results. with color-coded adaptors for proper insertion.Radiometer calibration is traceable to NIST, with calibration Precisionvalid for one year. Proprietary optical interface virtually eliminates beam profile*Measures power and irradiance from any UV curing system dependence and significantly improves measurement accuracy.commercially available. PC Control Panel SoftwareCalibrate Multiple Units PC Software memory capability for storing calibration andThe handheld unit also allows you to calibrate multiple curing measurement data for process validation and quality assurance.systems from the same radiometer through serial communication.The unit can be connected by up to four remote sensors. Custom Sensors Sophisticated electronics built into the OmniCure R2000 Radiometer allow for connection to custom sensors to measure light energy directly at the cure site. www.excelitas.com

Light Guides& AccessoriesThe OmniCure S Series offers single-legged and multi-legged, liquid-filledor fiber Light Guides to best meet customers’ needs, as well as a range ofother accessories.12 345 61 Liquid Light Guides 2 High Power Fiber Light Guide 3 High Power Fiber Light Lines Available in 3, 5 and 8mm tip Provides over 50% more Utilizes technology developed in diameters. An economical choice throughput power than industry the High Power Fiber Light Guides for light delivery. Standard standard fiber guides for greater to provide a high output linear lengths range from 750 to flexibility in your curing process. beam of curing energy. The fibers 3000mm. Dual configurations for Technology in multi-legged guides are continuous from the light guide multi-site curing. supplies an equal distribution of input to termination eliminating light energy to multiple cure sites coupling losses seen with standard from a single source. light line accessories. Ideal for bonding of main seal, chip on glass,4 Adjustable Collimating Adaptor 5 Light Line TAB & flexible printed circuit on flat panel displays.Ideal for any application that Converts the Light Guide’s spot ofrequires a uniform spot from 1\" light into a focused, linear beam of 6 Cure Ringup to 6\" (2.54cm to 15.2cm). Equal curing energy. Efficiently cures smalldistribution of power allows the rows of components, inks on tubing Allows a Light Guide 360° of curinguser to cure adhesive evenly and cable, anything that requires power. Standard ring for use withwithout having to compensate for up to two inches of line length. Also Liquid Light Guides available inuneven light distribution. performs tacking and strain relief of solid or slotted versions. Ideal for multi-strand wiring, as well as edge bonding a number of medical bonding of flat panel displays. devices such as catheters and also tubes, cables or any other parts that require 360° curing.

Tools forProcess ValidationThe following OmniCure features contribute to our unmatched capability in process validation:Timer Sync Output Calibrate System TimerShutter Verification Output Verify shutter opens and closesShutter, Light Guide & Lamp Alarms Confirm processCalibration traceable to NIST Calibrated OmniCure R2000 Radiometer used to calibrate the OmniCure S2000 and S1500 is traceable to NISTExposure Fault Output Verify that intensity does not deviate more than ±10% from current intensity settingPC Control Panel Software Query the status of the Intelli-Lamp, calibration, alarms, and shutter positionCommands with the OmniCure S2000 and S1500 www.excelitas.com

Maximum Flexibility and Process Control as the various modes of operation that areThe OmniCure® PLC2000 is an innovative product accessory supported. Temperature,specially designed to complement the OmniCure AC Series of operational hours, intensityhigh power UV LED curing systems. When connected to an control, and timer/pulseOmniCure AC Series UV LED head, this multipurpose external output modes can be easilycontroller device enables the immediate ability to intelligently accessed and modified tomanage, monitor, and control an LED system. provide unmatched performance control.Providing unparalleled control of the OmniCure UV LED systems, Supporting RS232 and RS485 communications, the PLC2000 isthe PLC2000 can be used to dynamically adjust the output a robust accessory for the OmniCure AC Series of products and,intensity, exposure time, and on/off capabilities while providing when paired with a system, allows for multiple UV LED headssystem information and error monitoring. With flexibility of to be daisy-chained and accessed or controlled through a singleoperating the PLC2000 locally or remotely through an automated computer terminal.system, the portable and compact PLC controller is well suitedfor use in manufacturing environments, laboratory or research & With quick set-up, easy integration, and intuitive features suchdevelopment applications. as a door lock for safety assurance, the PLC2000 is a perfect accessory to complement the AC Series and provide a completeThe OmniCure PLC2000 features a comprehensive display of LED curing solution for your applications.  UV LED curing system information with LED indicators updatingcritical details such as power on and initialization states, as wellFEATURES BENEFITS Intelligent digital control Unparalleled control to dynamically adjust to a wide range of settings: • Intensity • Control in 1% increments • Exposure timer • Set timed operation • Pulsed operation • Fine-tune on/off illumination – pulse frequency or duty cycle LCD Display Easy access to UV LED system information and making changes to operational modes: • Temperature and LED hours Remote or local operation • Programmability of different user modes Control via RS485 or RS232 Flexibility to robustly support different configurations; Simple integration with no computer PLC fault indicators programming required for local operation Powered from UV LED Head Plug and play Point-to-point or daisy-chain addressability Convenient monitoring with status and error identification Simplified connectivity with no electrical requirements Auto detection and calibration with OmniCure® AC Series UV LED curing solutionsTECHNICAL SPECIFICATIONS 180 mm (7.07”) x 91 mm (3.57”) x 41 mm (1.63”) HD15 for connection to UV LED head and for customer Outer Dimensions (L x W x H) PLC control port RJ11 – RS485 daisy-chain in and out Connectivity Local: LED On/Off, Intensity, exposure timer, pulse mode operation Controls Remote: Function programmability via PLC commands Alarms Door Lock Temperature, drive current continuity Integrated safety feature to prevent accidental UV exposure www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014

OmniCure LX500 availablein 2 or 4 channelconfigurations.Outstanding Optical Stability LED heads provide fast, even curing of UV adhesives for superior product quality, rapid production, and lower manufacturingThe OmniCure® LX500 system is designed with proprietary costs. The LED Max heads are offered in 55mm and 130mmIntelli-Lamp LED technology that monitors LED head lengths and in 365nm, 385nm and 400nm wavelengths. Thesetemperature, lifetime data, and automatically maintains new and improved LED heads are color coded to indicateoptical stability +/- 5% during an exposure. Available in wavelength and reduce setup time.either 2 or 4 channel configurations, the OmniCure LX500is the most flexible and cost effective option for industrial LX500 385 nmmanufacturing. The LED Max heads deliver exceptional peakirradiance of up to 14 W/cm2 (365nm), 16 W/cm2 (385nm) Easy Integrationand 9 W/cm2 (400nm) using a 3mm focusing lens at a 10mmworking distance. The compact size of the OmniCure LX500 allows for easy integration into any process setup. The LX500 is equipped withExceptional Process Control a newly designed 2.4 inch full color LCD that can be controlled using a four way keypad, by a programmable logic controllerFor long term stability of the light source, the new LED heads (PLC), or via USB connected directly into a PC. The Micro SDcan be calibrated to tight tolerances to ensure a repeatable technology provides additional programming capabilities andcuring process, and precise control of the UV irradiance. The allows application data and error faults to be recorded in realOmniCure LX500 features StepCure 2.0 which allows the time. The OmniCure LX500 features improved connectors thatoperator to program different profiles within a single LED head are easier to install and remove with an integrated lockingor multiple LED heads across each channel. With StepCure 2.0, mechanism.the operator can set exposure time, intensity level, dwell rateand trigger source. The LX500 combined with high power UV LX500 365 nm

UV LED Heads 12 mm 12 mmThe newly designed UV LED heads offer high peak irradiance and highly efficient cooling to 130 mm 55 mmmaximize continuous operation without over-heating. These features will minimize costly downtimeand extend the life of the LED heads, resulting in low cost of ownership and convenience thatmanufacturers can rely on. Due to its superior design, when properly clamped, the LED head maybe used continuously while remaining cool. The UV LED heads use an HDMI connector withan auto-lock feature that minimizes set up and installation time. Focusing Lenses OmniCure UV LED heads use replaceable focusing lenses that offer the flexibility essential to meet the spot size and irradiance level required for a specific application. Beam profiles for the OmniCure 365nm and 385nm UV LED MAX heads with the 3mm lenses are illustrated below. Additional beam profiles and technical information are available on our website (www.excelitas.com/omnicure).LED Calibration and Beam PositioningThe ability to calibrate and accurately measure light intensity from a UV LED spot curing system ischallenging for the UV assembly manufacturer and is a critical piece to controlling a UV curing process.The OmniCure LX500 controller is designed with an integrated radiometer that, when combined witha precise LED positioning fixture, allows operators to efficiently set and measure the peak irradianceaccurately and consistently in a UV process within a manufacturing environment. Key Benefits • Consistent measurements by accurately positioning the beam on the detector aperture • Reduction in calibration time and cost with its easy to use alignment tool • Elimination of the need for expensive and bulky alignment toolsStepCure - Programming Multiple Steps or Multiple HeadsThe OmniCure LX500 includes StepCure technology that allows the operator toconfigure input signals for triggering a step profile of one or more heads via itsdigital user interface. StepCure allows a variety of profile set-ups for: • Running a sequence of exposures on one head, at varying times and intensities • Running a sequence of exposures on multiple heads, at varying times and intensities • Running parallel exposures on multiple heads, each at different times and intensities • Programming multiple profiles for the same head from different trigger sourcesExample 1: Setting up a StepCure ProfileProfile # Time Level Dwell Src PLC1 1 1 1.5 75 0.1 PLC1 2 1 5.0 100 1.5 PLC1 3 1 2.0 50 6.5 www.excelitas.com

Technical Specification Energy ComparisonUV LED Heads 1 to 4 individual & interchangeable to Part Number OmniCure LX Series Controller2.4 \" Full Color Displays any channel. 010-00369R OmniCure LX500 Controller - 2 Channel Main Control, Input Configurations, System 010-00375R OmniCure LX500 Controller - 4 ChannelMode Control Maintenance, LED Information, Calibration, Mirco SD Log Information.Timer 4 Way membrane control for system display and programming.Intensity Level Countdown Mode: Range programmable fromStart/Stop 999.9s to 0.1s, in 0.1s intervals.Power On/Off Count Up Mode: User control timing via theAlarms front panel or foot pedals.Controller Dimensions 5-100% (with 1% increments)External Control Description Control start or stop of theOperating Conditions LED emission.Operating Voltage Separate power on/off controller.Power Consumption Alarm icon will appear on screen in the event of an error or fault.Ambient Temperature/ (H) 5.5”, (W) 3.5\", (D) 5.5\"Humidity Range Via optional foot pedal, PLC, or PC through USBStorage Temperature/ communication.Humidity RangeCertifications & Safety Controller Supply Input: 12 VDC Input to ACStandards adaptor: 100-120VAC orWarranty 200-240VAC (+/-10%) & 50/60Hz. 72W max at 120VAC 104W max at 240VAC (with 4 UV LED heads in operation) 5° to 35°C, 85% max. (no condensation) -10° to 60°C, 85% max. (no condensation) RoHS compliant and meets CE requirements 1 yearHeight 5 ½ “ (139.7mm) Height 5 ½ “ (139.7mm) Depth 5 ½ “ (139.7mm) Width 3 ½ “ (88.9mm) Width 3 ½ “ (88.9mm)Front View Back View www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055© 2016 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neitherExcelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for referencepurposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 04.2016

A Versatile Conveyor Solution With Multiple Configurations AvailableThe OmniCure® CV300 is designed to be a complementary accessory for the OmniCure AC Series UV curing solutions, and supportsthe entire product family. It is a versatile solution that allows customers to quickly integrate UV LED curing systems into a conveyorplatform. The unique mounting design of the Omnicure CV300 conveyor allows for multiple configurations of the OmniCure ACSeries high power UV LED area curing systems to be integrated. The LED systems can be positioned perpendicular to the conveyorbelt’s direction of travel or in 15 degree steps towards a parallel orientation.Orienting the LED systems perpendicular to the direction of travel will maximize the curing width. Orienting the LED heads parallelto the direction of travel will maximize the curing dose. Go to www.excelitas.com/omnicure/ac-series/cv300 for more information onavailable system configurations and the potential dose for each orientation of the mounting head.Technical SpecificationsOmniCure CV300 1070 mm (42.2\") x 540 mm (21.2\") x DimensionsOverall Dimensions 440 mm (17.3\") All dimensions in inches.(LxWxH) 305 mm (12\") open mesh Teflon®Belt Width coated fiberglassClearance 385 mmBelt Speed 1 m/min to 14.5 m/min (3 ft/min to 48 ft/min)Height Adjustment 30 mm to 60 mm in 10 mm incrementsHead Angle Adjustment 0 to 90 degrees relative to belt travelHead Angle Adjustment direction in 15-degree incrementsElectricalControls 34 kg (74 lbs) 100-240 V AC, 50/60 Hz, single phase Power on, Speed adjust, LED onTo learn more about OmniCure UV curing solutions, please visit www.excelitas.com/omnicure. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 09.2014

Outstanding Optical Performance Superior UniformityOmniCure® AC8225-F UV LED curing system is specifically designed for The OmniCure AC8225-F fiber curing system utilizes a patented processfiber curing applications. With a custom optical design and advanced for addressing individual UV LED module outputs, to provide exceptionalfront-end optics, the AC8225-F provides high peak irradiance and uniformity over the entire curing area. Multiple UV LED heads can beexceptional uniformity at specific working distances. The system delivers adjoined while maintaining optical uniformity between each system.12W/cm2 peak irradiance at a 10 to 18 mm working distance for fast,even curing in fiber coating applications. By adapting the output to AC8225-F Uniformity – 395 nmsupport the requirements of the application, the OmniCure AC8225-Fprovides optimized performance for this demanding curing process. AC8225-­‐F  Uniformity  Irradiance vs Working Distance – 395 nm 1  Irradiance  (W/cm2)   0.9   Real%ve  Power  per  Unit  Length     0.8   Irradiance  Distribu2on     0.7   5mm   0.6   10mm  14   10mm   0.5   15mm  12   13mm   0.4   20mm  10   15mm   0.3   30mm   18  mm   0.2   8   0.1   50   100   150   200   250   300   350   400   450   6   Longitudinal  Displacement  (mm)   4   0   2   0   0   10   20   30   40   50   Technical Specifications 0   Loca2on  (mm)  or  Orthogonal  Displacement  (mm)   OmniCure AC8225-F Peak Wavelengths 395 nm ± 5 nm 225 x 15 mm Active Optical Area 600WExceptional Cost Savings Power Consumption* 11.7 12.2OmniCure AC8225-F UV LED fiber curing system reduces electricity Typical Peak Irradiance (W/cm2) 12.4consumption by up to 60% compared with traditional arc lamp 12.3systems for exceptional cost savings with no compromises in line speed. Working 10 mm Better than ± 10%With over 40,000 hours of LED lifetime and no replacement parts, 48 V DC ± 2 Vmaintenance costs are even further reduced. Distance 13 mm 235 x 80 x 218 mm 2.7Ease of Integration 15 mm Air >40,000 hoursUtilizing air-cooled LED technology, the compact OmniCure AC8225-F 18 mm Integrated PLC controlsUV LED curing system allows for seamless integration into new or 3 years or 20,000 service hoursexisting production lines. The innovative design eliminates the need for Longitudinal Uniformity*costly retooling, external cooling or ozone extraction. The AC8225-Fcan also be mounted in any orientation for greater flexibility. External Operating Voltagemechanical and optical accessories are also available upon request. Dimensions (L x W x H)For mechanical drawings and further information about theOmniCure AC8225-F UV LED curing system, please contact us at Weight (kg)[email protected]. Cooling Life Expectancy (L70) Automation LED Warranty *At 100% intensity setting. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2016 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 03.2016

Exceptional Irradiance Performance Flexibility with ControlInnovatively designed with advanced front-end optics, the OmniCure® Precise control of the UV irradiance level and time ensures that theAC7150 and AC7300 air-cooled, LED curing systems allow for fast, even correct dose of UV energy at the required wavelength is providedcuring by providing high peak irradiance at long working distances with on every exposure for a repeatable curing process. Intelligent systemextended clearance from conveyed parts. The customized optics offer monitoring and control ensures system reliability meets the demands formaximum flexibility in focusing the light at specific working distances any application.and easily adapts to specific UV process needs. Ease of Integration Irradiance vs Working Distance for the AC7 Series – 365 nm The air-cooled, compact LED head design eliminates the need forIrradiance (W/cm2) 3.5 5 mm external cooling or ozone extraction while simplifying integration. 3.0 10 mm The curing systems can be mounted in any orientation with external 2.5 20 mm mechanical and optical accessories available for maximum flexibility. 2.0 30 mm 1.5 1.0 Technical Specifications 0.5 AC7150 AC7300 0 10 15 20 25 30 35 40 45 LED Peak Wavelengths 365 nm ± 5 nm, 395 nm ± 5 nm Lateral Displacement (mm) Active Optical Area 152 x 15 mm 305 x 15 mm Typical Irradiance (W/cm2) 365 nm 395 nm 365 nm 395 nm Working 1 mm 2.8 5.2 2.8 5.2 Distance 10 mmSuperior Uniformity & Extendible 2.6 4.4 2.6 4.4The OmniCure AC7150 and AC7300 provide high longitudinal 20 mm 2.1 3.6 2.1 3.6uniformity to ensure consistent and repeatable curing of all parts overthe entire 150 mm (6\") to 300 mm (12\") curing area. Multiple systems 30 mm 1.6 2.9 1.6 2.9can be adjoined side-by-side in any combination of the AC7150 andAC7300 to extend the addressable curing area and meet any application 40 mm 1.2 2.4 1.2 2.4size without compromising optical performance. 50 mm 1.0 2.0 1.0 2.0 Optical Power* 40 W 80 W 80 W 160 W Power Consumption* 330 W 650 W Longitudinal Uniformity* ± 10%Uniformity at Working Distances for the AC7300 Uniformity Between Better than ± 10% at 20 mm or greater Adjoined Heads working distance 1 0.8Relative Power Per Unit 10 mm Operating Voltage 48 V DC ± 2 V 0.6Length 20 mm 0.4 30 mm Dimensions (L x W x H) 152 x 100 x 148 mm 305 x 100 x 148 mm 0.2 Weight 1.8 kg (3.9 lbs) 3.2 kg (7.0 lbs) Cooling Air Acoustic Noise < 65 dBA, load adapting Life Expectancy > 20,000 hours Automation Integrated PLC controls for UV intensity and system alarms 0 50 100 150 200 250 300 350 400 Longitudinal Displacement (mm) Warranty 1 year; 10,000 service hours (light engine)Uniformity Between Adjoined Heads for the AC7 Series *At 100% intensity settingRelative Power Per Unit 1 10 mm Mechanical Drawings Length 0.8 20 mm Mechanical drawings are available on our website. To find out more 30 mm about the OmniCure AC Series UV LED curing solutions, please visit www.excelitas.com/omnicure 0.6 0.4 0.2 0 100 200 300 400 500 600 700 Longitudinal Displacement (mm)All performance data is measured using spectrometer and are NIST traceable. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014

Outstanding Optical PerformanceIrradiance (W/cm2) Exceptional Process ControlThe OmniCure® AC9150, AC9150P, AC9225, AC9225P, AC9300 For a repeatable curing process, precise control of the UV irradiance leveland AC9300P air-cooled UV LED curing systems are designed and time ensures that the correct dose of UV energy is provided on everywith advanced front-end optics to provide high power, high peak exposure. System error detection notifies users for as low as 1% faultyirradiance and exceptional uniformity at different working distances. LEDs to ensure process repeatability. Intelligent system monitoring andThe systems deliver 14 W/cm2 peak irradiance for fast, even curing at control ensures system reliability meets the demands of any application.long working distances. P versions of the AC9 Series have enhancedoptics to optimize the dose for short working distances along with a Ease of Integrationremovable window for easy cleaning to support print applications. By adapting the output to support the process requirements of the OmniCure UV LED curing systems utilize air-cooled LED technology in aindustry, the new AC9 Series' product portfolio can be applicable for compact design allowing for seamless integration into new or existinga range of varying applications with different process needs. production lines. The innovative design eliminates the need for costly Irradiance vs. Working Distance for AC9 Series – 395 nm retooling, external cooling or ozone extraction. The curing systems can also be mounted in any orientation for greater flexibility. External Lateral Displacement (mm) mechanical and optical accessories are also available upon request.Superior Uniformity Mechanical DrawingsThe OmniCure AC9 Series utilizes a patented process for addressing Mechanical drawings are available upon request. To find out moreindividual UV LED module outputs, and providing exceptional about the OmniCure AC Series of UV LED curing solutions, please visituniformity over the entire curing area. Multiple UV LED heads can be www.excelitas.com/omnicureadjoined while maintaining optical uniformity between each system.The flexibility to achieve larger curing areas in a variety of customizable Technical Specificationslengths enables manufacturers to improve throughput withoutcompromising on performance. AC9150/AC9150P AC9225/AC9225P A9300/AC9300P AC9 Series Uniformity – 395 nm LED Peak 150 x 25 mm 395 nm 300 x 25 mm Longitudinal Displacement (mm) Wavelengths 1058 W 225 x 25 mm 2116 W Active Optical Area Power 1587 W Consumption* Typical Peak 395 nm Irradiance (W/cm2) 14 14 14 1 mm 12.6 12.6 12.6 5 mm 10.6 10.6 10.6 Working 10 mm 9.06 9.06 9.06 Distance 15 mm 7.7 7.7 7.7 20 mm 6.7 6.7 6.7 25 mm 365 W 574 W 730 W Optical Power* Longitudinal Better than +/-10% Uniformity*Relative Power per Unit Length Operating Voltage 48 V DC ± 2 V Dimensions (L x W x H) 159 x 80 x218 mm 235 x 80 x218 mm 311 x 80 x218 mm Weight (kg) Cooling 1.8 2.7 3.6 Life Expectancy Air Automation > 20,000 hours LED Warranty Integrated PLC controls for UV intensity and system alarms 2 years or 10,000 service hours *At 100% intensity setting www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055© 2016 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neitherExcelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for referencepurposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 01.2016

Outstanding Optical Performance Superior UniformityThe OmniCure® AC8150, AC8150P, AC8225, AC8225P, and AC8300 The OmniCure AC8 Series utilizes a patented process for addressingair-cooled UV LED curing systems are designed with advanced individual UV LED module outputs, and providing exceptionalfront-end optics to provide high power, high peak irradiance and uniformity over the entire curing area. Multiple UV LED heads can beexceptional uniformity at different working distances. The systems adjoined while maintaining optical uniformity between each system.deliver over 8 W/cm2 peak irradiance for fast, even curing at long The flexibility to achieve larger curing areas in a variety of customizableworking distances. P versions of the AC8 Series (AC8150P and lengths enables manufacturers to improve throughput withoutAC8225P) have enhanced optics to optimize the dose for short compromising on performance.working distances required by print applications. By adapting theoutput to support the process requirements of the industry, the new Relative Power per Unit LengthAC8 Series Uniformity – 395 nmAC8 Series product portfolio can be applicable for a range of varying 1.2applications with different process needs. 1.0 0.8Irradiance vs. Working Distance for AC8 Series – 395 nm 0.6 1 mm 0.4 5 mm 10.0 1 mm 10 mm 0.2 15 mmIrradiance (W/cm2) 5 mm 20 mm 8.0 10 mm 30 mm 6.0 20 mm 30 mm 4.0 50 mm 2.0 0 50 100 150 200 250 300 350 400 Longitudinal Displacement (mm) 0 50 100 150 200 Technical Specifications Lateral Displacement (mm) AC8150 AC8225 AC8300Irradiance vs. Working Distance for AC8 Series – 365 nm LED Peak 365 nm ± 5 nm, 395 nm ± 5 nm Wavelengths 5.0 1 mm Active Optical 150 x 25 mm 225 x 25 mm 300 x 25 mm 5 mm AreaIrradiance (W/cm2) 4.0 10 mm 3.0 20 mm Power 956 W 1430 W 1904 W 30 mm Consumption* 2.0 50 mm Typical Peak 365 nm 395 nm 365 nm 395 nm 365 nm 395 nm Irradiance 1.0 (W/cm2) 0 20 40 60 80 100 Working 1 mm 4.0 8.5 4.0 8.5 4.0 8.5 Lateral Displacement (mm) Distance 10 mm 3.0 6.2 3.0 6.2 3.0 6.2 20 mm 2.3 4.5 2.3 4.5 2.3 4.5 30 mm 1.9 3.8 1.9 3.8 1.9 3.8Exceptional Process Control 40 mm 1.5 3.0 1.5 3.0 1.5 3.0For a repeatable curing process, precise control of the UV irradiance level 50 mm 1.2 2.5 1.2 2.5 1.2 2.5and time ensures that the correct dose of UV energy is provided on everyexposure. Multiple wavelengths are available to match the requirements Optical Power* 133 W 273 W 200 W 410 W 267 W 547 Wof the material to be cured. Intelligent system monitoring and controlensures system reliability meets the demands of any application. Longitudinal Better than ± 10% Uniformity*Ease of Integration Operating 48 V DC ± 2 VOmniCure UV LED curing systems utilize air-cooled LED technology in a Voltagecompact design allowing for seamless integration into new or existingproduction lines. The innovative design eliminates the need for costly Dimensions 159 x 80 x218 mm 235 x 80 x218 mm 311 x 80 x218 mmretooling, external cooling or ozone extraction. The curing systems (L x W x H)can also be mounted in any orientation for greater flexibility. Externalmechanical and optical accessories are also available upon request. Weight (kg) 3.6 2.5 4.4 2.7 5.2 2.9Mechanical Drawings Cooling AirMechanical drawings are available on our website. To find out more Life Expectancy > 20,000 hoursabout the OmniCure AC Series of UV LED curing solutions, please visitwww.excelitas.com/omnicure Automation Integrated PLC controls for UV intensity and system alarmsAll performance data is measured using spectrometer and are NIST traceable. LED Warranty 2 years or 10,000 service hours *At 100% intensity setting. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055© 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neitherExcelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for referencepurposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 10.2014

Exceptional Irradiance Performance Ease of IntegrationThe OmniCure® AC450 and AC475 utilize high emission LEDs which The air-cooled, compact LED head design eliminates the need forachieve over 8 W/cm2 at the optics window. The systems include external cooling or ozone extraction while simplifying integration.advanced front-end optics to provide high peak irradiance at long The curing systems can also be mounted in any orientation, usingworking distances with extended clearance of conveyed parts. This different wavelengths for greatest flexibility. External mechanical andallows for easier curing, or the option of focusing the light at different optical accessories are also available for use in similar applications. working distances for adapting to a specific UV process. Technical SpecificationsIrradiance vs Working Distance for AC450 and AC475 – 395 nm AC450 AC475 LED Peak Wavelengths 365 nm ± 5 nm, 395 nm ± 5 nmIrradiance (W/cm2) Active Optical Area 50 x 25 mm 75 x 25 mm Typical Peak Irradiance (W/cm2) 365 nm 395 nm 365 nm 395 nm Working 1 mm 4.0 8.0 4.0 8.0 Distance 10 mm 2.8 5.7 2.8 5.7 20 mm 1.9 3.7 1.9 3.7 30 mm 1.5 2.8 1.5 2.8 20 40 60 80 100 120 140 40 mm 1.2 2.0 1.2 2.0 Lateral Displacement (mm) 50 mm 1.0 1.7 1.0 1.7 Optical Power* 45 W 90 W 68 W 135 WSuperior Uniformity Power Consumption* 330 W 480 WUtilizing Excelitas Technologies patented process for individually Longitudinal Uniformity* Better than ± 10%addressing each UV LED module output, the OmniCure AC450and AC475 offers consistent results by ensuring high longitudinal Operating Voltage 48 V DC ± 2 Vuniformity over the entire 50 mm (2\") to 75 mm (3\") curing area.A uniform exposure area allows for curing of larger and/or multiple Dimensions (L x W x H) 110 x 68 x 190 mmparts simultaneously. It also offers the ability to convert a static curingprocess to one where parts are being cured while in motion in order Weight 1.1 kg (2.4 lbs)to increase throughput. Cooling Air Acoustic Noise < 65 dBA, load adapting Life Expectancy > 20,000 hours Automation Integrated PLC controls for UV intensity and system alarms LED Warranty 2 years or 10,000 service hoursUniformity at Working Distances for the AC475 *At 100% intensity setting. 1Relative Power Per Unit Length 1 mm Mechanical Drawings 0.8 5 mm 0.6 10 mm Mechanical drawings are available on our website. To find out more 0.4 20 mm about the OmniCure® AC Series UV LED curing solutions, please visit 0.2 30 mm www.excelitas.com/omnicure 40 mm 0 20 40 60 80 100 120 140 160 180 200 50 mm Longitudinal Displacement (mm)Flexibility with ControlPrecise control of the UV irradiance level and time ensures that thecorrect dose of UV energy at the required wavelength is providedon every exposure for a repeatable curing process. Intelligent systemmonitoring and control ensures system reliability meets the demandsfor any application.All performance data is measured using spectrometer and are NIST traceable. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2016 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 03.2016

Superior Optical Performance Flexibility with ControlThe OmniCure® AC550, AC550P, AC575 and AC575P air-cooled UV Precise control of the UV irradiance level and time ensures that theLED curing systems are designed with advanced front-end optics to correct dose of UV energy at the required wavelength is providedprovide high power, high peak irradiance and exceptional uniformity on every exposure for a repeatable curing process. Intelligent systemat different working distances. The systems deliver 14W/cm2 peak monitoring and control ensures system reliability meets the demandsirradiance for fast, even curing at long working distances. The print for any application.versions of the AC5 Series have enhanced optics to optimize the dosefor short working distances along with a removable window for easy Ease of Integrationcleaning to support print applications. By adapting the output tosupport the process requirements of the industry, the new AC5 Series' The air-cooled, compact LED head design eliminates the need forproduct portfolio can be applicable for a range of varying applications external cooling or ozone extraction while simplifying integration.with different process needs. The AC5 Series UV LED curing systems can also be mounted in any orientation, using different wavelengths for greatest flexibility.Irradiance vs Working Distance for AC550 / AC550P and External mechanical and optical accessories are also available for use AC575 / AC575P – 395 nm in similar applications.  AC5  -­‐395nm   Technical Specifications 16   14   12   AC550 / AC550P AC575 / AC575PIrradiance  (W/cm2)   10   1   LED Peak Wavelengths 395 nm ± 5 nm 5   Active Optical Area 50 x 25 mm 75 x 25 mm 8   10   Typical Peak Irradiance (W/cm2) 395 nm 6   15   20   Working 1 mm 14 4   25   Distance 5 mm 12.6 2   10 mm 10.6 0   20   40   60   80   100   120   140   160   15 mm 9.0 0   Lateral  Displacement  (mm)   20 mm 7.7 25 mm 6.7Exceptional Uniformity Optical Power 123 W 184 WUtilizing Excelitas Technologies® patented process for individually Power Consumption* 330 W 480 Waddressing each UV LED module output, the OmniCure AC5 Seriesoffers consistent results by ensuring high longitudinal uniformity Longitudinal Uniformity* Better than ± 10%over the entire 50 mm (2\") to 75 mm (3\") curing areas. A uniformexposure area allows for curing of larger and/or multiple parts Operating Voltage 48 V DC ± 2 Vsimultaneously. It also offers the ability to convert a static curingprocess to one where parts are being cured while in motion in order Dimensions (L x W x H) 110 x 68 x 190 mmto increase throughput. Weight 1.1 kg Uniformity at Working Distances for the AC575 Cooling Air Acoustic Noise < 65 dB Life Expectancy > 20,000 hours Automation Integrated PLC controls for UV LED Warranty 2 years or 10,000 service hours *At 100% intensity setting. Mechanical Drawings Mechanical drawings are available upon request. To find out more about the OmniCure AC Series UV LED curing solutions, please visit www.excelitas.com. www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055For a complete listing of our global offices, visit www.excelitas.com/locations© 2016 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, andneither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein forreference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 03.2016

Outstanding Optical Performance Superior UniformityThe OmniCure® AC275 and AC2110 air-cooled UV LED curing systems The OmniCure AC2 Series utilizes a patented process for addressingare designed with advanced front-end optics to provide high peak individual UV LED module outputs, and provides exceptional uniformityirradiance and exceptional uniformity. The standard AC2 systems over the entire curing area. Multiple UV LED heads can be adjoinedprovide a reduced output angle from typical LED systems, ideal for while maintaining optical uniformity between each system. Theprinting applications, to help eliminate back reflection of the light flexibility to achieve larger curing areas in a variety of customizableto the print heads. Customized optics are available to maximize the lengths enables manufacturers to improve throughput withoutirradiance for longer working distances. All AC2 Series come with a compromising on performance.flat outer surface that allows for easy cleaning and replacement forongoing maintenance. By adapting the output to support the process AC2 Series Uniformity – 395 nmrequirements of the industry, the new AC2 Series product portfolio 100can be applicable for a range of varying applications with different 80process needs. 60Irradiance (W/cm2) 40 3 mm Relative Power per Unit Length (%) 20 5 mmIrradiance vs. Working Distance for AC2 Series – 395 nm 10 mm 15 mm3.0 1 mm 20 mm2.5 3 mm2.0 5 mm 0 20 40 60 80 100 120 140 160 180 2001.5 10 mm Longitudinal Displacement (mm)1.0 15 mm0.5 20 mm 0 Technical Specifications -3 -2 -1 0 1 2 3 Lateral Displacement (cm) AC275 AC2110Ease of Integration LED Peak 395 nm ± 5 nm, 365 nm ± 5 nm WavelengthsOmniCure AC2 Series UV LED curing systems utilize air-cooled LEDtechnology to provide high irradiance in a very compact design Active Optical 10 x 76 mm 10 x 114 mmallowing for seamless integration into new or existing print systems Areaor production lines. The curing systems can also be mounted in anyorientation for greater flexibility. External mechanical and optical Typical Peak 395 nm 395 nmaccessories are also available upon request. Irradiance (W/cm2)Mechanical Drawings Working 1 mm 2.6 2.6Mechanical drawings are available on our website. To find out more Distance 3 mm 2.3 2.3about the OmniCure AC Series of UV LED curing solutions, please visitwww.excelitas.com/omnicure 5 mm 1.9 1.9Exceptional Process Control 10 mm 1.2 1.2For a repeatable curing process, precise control of the UV irradiance 15 mm 1.0 1.0level and exposure time ensures that the correct dose of UV energyis provided every time. Intelligent system monitoring and control 20 mm 0.8 0.8ensures system reliability meets the demands of any application.Multiple wavelengths are available to match the requirements of the Optical Power* 13 W 19 Wmaterial to be cured. Longitudinal Better than ± 10% Uniformity* Operating 48 V DC ± 2 V Voltage Dimensions 79 x 29 x 129 mm 117 x 29 x 129 mm (L x W x H) Weight (kg) 0.3 0.44 *At 100% output setting Note: All measurements are taken using the EIT PowerPuck II radiometer with UVA2 filter.www.excelitas.com 2260 Argentia Road Telephone: +1 905 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055© 2015 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neitherExcelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for referencepurposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 02.2015

The Right Choice forArea Curing ApplicationsDesigned for Demanding Medical, Ease of Integration with MaximumIndustrial and Electronics Manufacturing FlexibilityApplications Designed as a self-contained solution, the OmniCure AC SeriesThrough harnessing advanced technologies, the OmniCure® UV LED curing systems eliminate the need for external cooling,AC Series of UV LED curing systems provide precise UV delivery thereby simplifying integration into new or existing productionin both automated and stand-alone applications, resulting in line infrastructures. Front-end optics allow for high irradiance atimproved process yields and high throughput performance. long working distances with extended clearance from conveyedCustomers benefit at all levels of design and integration parts. For maximum flexibility, front-end optics allow the abilitywith using the air-cooled, UV LED curing systems which are to focus the light at different working distances and easilysynonymous with efficiency and quality; and are reinforced by adapt to specific UV process needs. With a small footprint andour commitment to the highest quality and award-winning straight-forward mounting, the AC Series enables integratorscustomer support. to focus on what is most important to their process.High Optical Power, Increased Cost Savings and EnvironmentallyThroughput, Highest Productivity FriendlyThe OmniCure AC Series is innovatively designed to provide Engineered with highest efficiency in mind, the OmniCurean exceptionally uniform area of high optical power for fast, AC Series allows manufacturers to minimize operational andeven curing of adhesives, coatings and inks. Integrating the maintenance costs associated with either traditional arc-lampvery latest in LED technology, the narrow-band nature of UV or other liquid-cooled LED systems. Precise irradiance controlemission enables the delivery of high irradiance to substrates allows UV energy to be generated at the required level and onlywithout heat-induced damage or distortion. With higher speeds when necessary, further increasing cost savings and minimizingand less waste through scrap, productivity and profits are carbon footprint. With no mercury content, and absence ofmaximized. ozone emissions, the costly requirements for additional air ventilation are eliminated, providing a cost-effective solution while ensuring a safe working environment.Medical Electronics Optoelectronics Printing www.excelitas.com 2260 Argentia Road Telephone: +1 905 821-2600 [email protected] Mississauga, Ontario Toll Free (USA and CAN): +1 800 668-8752 L5N 6H7 CANADA Fax: +1 905 821-2055 For a complete listing of our global offices, visit www.excelitas.com/locations © 2014 Excelitas Canada Inc. OmniCure® is a registered trademark of Excelitas Canada Inc. The Excelitas logo and design are registered trademarks of Excelitas Technologies Corp. All other trademarks are the property of their respective owners, and neither Excelitas Technologies Corp., its affiliates or subsidiaries, or any of their respective products, are endorsed or sponsored by or affiliated in any way whatsoever with those organizations whose trademarks and/or logos may be mentioned herein for reference purposes. Excelitas Canada Inc. reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 07.2014www.excelitas.com


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook