Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore NLCC

NLCC

Published by fazligorgin, 2019-04-12 11:00:49

Description: NLCC

Search

Read the Text Version

M G C Design Consultants

1 2345 1a 1b A 1bx B C D E Clear Space F G H 1 Ground Floor Plan I A003 Scale: 1:200 J M A003 G Ground Floor Plan C Ninth Line & Tacc Community Centre Design Consultants

Materials Legend: T.O. Lec. Theatre 1 - Limestone Panelling +12,890 2 - Glazing 3 - Exposed Concrete Fdn. T.O. Slab 4 - Precast Conc. Sweep +9700 5 - Cultured Stone 6 - Metal Roof Second Floor Para 7 - Alum. Parapet Cap and EPDM +9100 Membrane Second Floor +4600 First Floor Parape +4000 T.O. Slab +250.0 Grade Level +0.00 1 North Elevation A007 Scale: 1:100 T.O. Lec. Theatre M +12,890 T.O. Slab +9700 Second Floor Parapet +9100 Second Floor +4600 First Floor Parapet +4000 T.O. Slab +250.0 Grade Level +0.00 2 South Elevation A007 Scale: 1:100 A007 G North and South Elevations C Ninth Line & Tacc Community Centre Design Consultants

Materials Legend: MISSISSAUGA LIBRARY T.O. Lec. Theatre 1 - Limestone Panelling +12,890 2 - Glazing West Elevation 3 - Exposed Concrete Fdn. T.O. Slab 4 - Precast Conc. Sweep Scale: 1:100 +9700 5 - Cultured Stone 6 - Metal Roof Second Floor Parapet 7 - Alum. Parapet Cap and EPDM +9100 Membrane Second Floor +4600 First Floor Parapet +4000 T.O. Slab +250.0 Grade Level +0.00 1 T.O. Lec. Theatre A008 +12,890 T.O. Slab +9700 Second Floor Parapet +9100 Second Floor +4600 First Floor Parapet +4000 T.O. Slab +250.0 Grade Level +0.00 2 East Elevation M A008 Scale: 1:100 A008 G East and West Elevation C Ninth Line & Tacc Community Centre Design Consultants

A1 23 4 5 1bx 1a 1b 2 A400 Top of Roof 8500 Storage 210 B Second Floor 4500 Book Drop Work Janitor Office . Gen. Office Rm. Rm. Rm. 110 111 102 105 103 First Floor 0 U/S Footing M -3500 G C Design Consultants 1 Building Cross Section @Grid C A301 Scale: 1:150

Top of Masonry TYPICAL FLOOR CONSTRUCTION TYPICAL EXT. WALL - PARAPET 9100 75mm Gravel Layer with Filter Fabric 20mm CMU 2 Layers 38m Rigid Insulation 38mm Rigid Insulation Single Ply Roof Membrane Air Barrier Thermal Barrier 37.5mm Air Gap Steel Decking C/W Concrete Fill 90mm Limestone Paneling Suspended Ceiling Below Second Floor TYPICAL FLOOR CONSTRUCTION 125mm Concrete Tile on TYPICAL EXT. WALL - SECOND FLOOR 4600 Steel Decking C/W Concrete Fill 90mm Limestone Paneling Suspended Ceiling Below 37.5mm Air Gap Air Barrier TYPICAL GROUND FLOOR CONSTR'N 38mm Rigid Insulation 125mm Concrete Tile on 12.5 Plywood Sheathing Moisture Barrier on 200mm Steel Stud C/W Batts Insulation 125mm Sand on Vapor Barrier Undisturbed Soil 12.5mm Gypsum Wall Board TYPICAL EXT. WALL - GROUND FLOOR M 90mm Cultured Stone 125 mm Concrete Sweep (940mm from base) G 90mm Limestone Paneling 37.5mm Air Gap C Air Barrier 38mm Rigid Insulation Design 12.5 Plywood Sheathing Consultants 200mm Steel Stud C/W Batts Insulation Vapor Barrier 12.5mm Gypsum Wall Board First Floor 0 TYPICAL FOUNDATION SYSTEM Undisturbed Soil 300mm Foundation Wall 37.5mm Rigid Insulation U/S Footing -3500 2 Wall Section A400 Scale: 1:25


Like this book? You can publish your book online for free in a few minutes!