Adsortion and desodorization 0 INFORMA- TION Nitropropane A Persistent odors A Trichlorethylene A Nonane A Stale odors A Sulphur trioxide * 1B Octalene A Ethylene oxide B Turpentine Octane A Mesityl oxide A Urea A Odorizes A A Tarmac fumes A Garlic smell A Ozone A Animal odor B B Paradichlorobenzene A Varnish fumes A PRE- Smell of dead animals A Adhesives A Fuel fumes C FILTERS Smell of roast meat A Onion smell A Pentane B Diesel fumes A Sour cabbage smell A Pentanone A Exhaust fumes 2B Smell of decomposed food A Pen ethylene * B Vinegar Smell of burnt food A Pentene * B B Xylene A Odor of rubber A A Smell of cigarette smoke A Perchlorethylene A Iodine A Perfumes and cosmetics A Iodoform A PAINTINGS Pyridine A Hydrogen Iodide * B BOOTHS Pollen B 3 PRODUCTS CONFOR 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 199 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Adsortion and desodorization INFORMA- Pellet Carbon TION Active Carbon Filters 1 Active carbon pellet, supplied in bags. Highly efficient filtration PRE- for the elimination of gaseous pollutants substances. With a FILTERS wide variety of options. Central air filtration of systems for the elimination of gaseous pollutants. Air treatment units, Hospital 2 centers, pharmaceutical laboratories, comfort and industrial facilities, chemical and food industry. Incineration / Niches / PAINTINGS Water treatment plants, dead animal deposits, hotels, restau- BOOTHS rants, discotheques, thermal and nuclear power plants, mu- seums, theaters, computer rooms, critical areas. 3 Features techniques PRODUCTS CONFOR Type: Active Carbon Filters Filtering element: Active pellet carbon or with impregnations for the filtration of very specific gases, (acid 4 vapors, isotopes radio, chlorine, formaldehyde, mercury, etc.) Supplied in bags of 25 kg. EPA/HEPA Advantages /ULPA Filtration of central ventilation systems, for the elimination of gaseous pollutants. 5 High efficiency filters can not cope with the problems of contamination by volatile or gaseous substances. Active carbon filters improve air quality, alleviating the discomfort of people produced by the “Sick Building” HIGH Syndrome by eliminating polluting gases and odors in urban environments that enter the offices through the TEMPERA- ventilation system through a chemical-physical process. TURE References 6 Reference Model Presentation Granulometry Density gr./l Humidity Hardness Sup. Ind. Adsorption mm. % % Esp. Iodine CCL4 % EQUIP- 0,48+-0,03 m2/gr. Mg / gr. MENTS CARB-4/25 CARB Pellet 4 0,50 5 97 55 CARB-ORGANICO CARB Pellet 8 x 30 4 98 900 950 50 7 CARB-FORMALDEHIDO CARB Pellet 4 x 10 0,52-0,58 4 98 700 min. 700 50 CARB Pellet 4 x 10 0,52-0,58 10 98 1000 50 MOTORS CARB-ACIDO CARB Pellet 4 x 10 0,52-0,58 4 98 1000 50 AND CARB-AMONIACO CARB Granulated 0,45+-0,02 10 97 1000 65 CARB-ISOTOPOS 14 1000 1000 TURBINES 1000 1000 1000 8 UxP (*) Stock ADSOR- Units per box F: Manufacturer, S: Stock, SL: Limited Stock TION AND DESODO- Venfilter RIZATION 200 Tel +34 937 862 607 [email protected] 9 Fax +34 937 862 493 www.venfilter.com INTER- NATONAL NORMATI- VE

Adsortion and desodorization NEW 0 Quebraven Galvanized Dimensions INFORMA- Impregnated carbon TION Active Carbon Filters 1 Panel filter with metal frame with filter media impregna- PRE- ted with active carbon. For the prefiltration of central air FILTERS treatment, conditioning and ventilation systems for the elimination of gaseous pollutants. 2 Features techniques PAINTINGS BOOTHS Type: Panel filter with metal frame with filter media impreg- nated with active carbon. 3 Frame: Galvanized steel. Grid: Metallic galvanized on both sides. PRODUCTS Filter element: Synthetic media impregnated with activated CONFOR carbon. Relative Humidity: 70%. 4 Temperature limit: 55ºC. EPA/HEPA Advantages /ULPA - Combined particles / molecules filtration. 5 - Low losses. - All dimensions. References HIGH TEMPERA- TURE Reference Model Dimensions Filtering Rated flow Unit Vol. UxP* Stock* 6 HxLxP Area (m2) (m3/h / Pa) (m3) QM122402CA Quebraven Metálico Carbón 1F EQUIP- QM122404CA Quebraven Metálico Carbón 287x592x48 0.7 1500/125 0.008 1F MENTS QM242402CA Quebraven Metálico Carbón 287x592x98 1.1 1700/195 0.016 1F QM242404CA Quebraven Metálico Carbón 592x592x48 1.3 3000/125 0.016 1F 7 592x592x98 2.2 3400/95 0.034 UxP (*) Stock (*) other sizes: pleased consult. MOTORS Units per box F: Manufacturer, S: Stock, SL: Limited Stock AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 201 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Adsortion and desodorization Dimensions INFORMA- Frame for carbon TION replaceable cartridge 1 Active Carbon Filters PRE- Frame for fitting the active carbon cylinders. FILTERS Features techniques 2 Type: Mounting for the cartridges. PAINTINGS Frame: Galvanized Steel, Stainless Steel or Plastic. BOOTHS Cartridge Fitting system: Fitting of cartridges on the quick bayonet mounting. 3 Advantages PRODUCTS CONFOR - Modular System. 4 References EPA/HEPA Reference Model Dimensions No. of Unit Vol. Weight (Kg) UxP Stock /ULPA LxHxP Cartridges (m3) * * BTCGV1224 BTC-GV 3 5 BTCGV2424 BTC-GV 305x610x75 8 0.02 5 1 F 610x610x75 16 0.03 1 F HIGH TEMPERA- UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock TURE Venfilter 6 202 Tel +34 937 862 607 [email protected] EQUIP- Fax +34 937 862 493 www.venfilter.com MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Adsortion and desodorization 0 Replaceable carbon INFORMA- cartridges TION Active Carbon Filters 1 Replaceable carbon cartridges for air entry and exit in Dimensions PRE- ventilation systems that require imporved odor absorption, FILTERS VOCs and the elimination of gases with low toxicity levels. 2 Features techniques PAINTINGS Type: Active carbon cylindrical cartridge. BOOTHS Carbon: Impregnated Active Carbon. Joint: Neoprene. 3 Temperature: Should not exceed 45ºC Relative Humidity: Maximum 70% PRODUCTS Contact time: According to the application it can vary from CONFOR 0.1 to 0.2 seconds. CALCULATION OF CONTACT TIME: Ct (sec.) = volume of 4 active carbon (m3) / flow to be treated m3/h seconds. Example EPA/HEPA Frame BTCGV2424 is fitted with 16 cartridges. /ULPA Cartridge CACGV145/450 contains 4.3 kg. Volume of carbon = 16 x 4.3 = 68.8 liters or 0.0688 m3/h 5 Flow to be treated in the installation 1,200 m3h CALCULATION HIGH Ct(sec.) = 0.0688 / 1200 x 3600 = 0.2 seconds TEMPERA- The contact time is 0.2 seconds, the flows would be as TURE follows: CACGV145/250 - 50 m3/h per cartridge 6 CACGV145/450 - 75 m3/h per cartridge CACGV145/600 - 100 m3/h per cartridge EQUIP- MENTS Advantages 7 - Reloadable cartridges with granulated active carbon. - Moludar system for adaptation to any installation. MOTORS AND References UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock TURBINES Reference Model Diameters Carbon Carbon (Kg) Minimum Rated flow(m3/h UxP Stock 8 (mm) Thickness contact 2,9 time (s) / Pa) ** ADSOR- 26 mm. 4,3 TION AND CACGV145/250 CAC-GV 145x85x250 26 mm. 5,7 0,1 100/80 1F DESODO- CACGV145/450 CAC-GV 145x85x450 26 mm. 0,1 150/80 1F RIZATION CACGV145/600 CAC-GV 145x85x600 0,1 200/80 1F 9 Venfilter [email protected] 203 Tel +34 937 862 607 www.venfilter.com INTER- Fax +34 937 862 493 NATONAL NORMATI- VE

0 Adsortion and desodorization INFORMA- Multicarb TION Active Carbon Filters 1 Multi-dihedral carbon filter with half fold and active PRE- carbon. FILTERS 2 Features techniques Dimensions PAINTINGS Type: Compact Polyhedral Rigid Bag Filter for deodorisation BOOTHS associated with a High Efficiency filter. Frame: Polypropylene. 3 Filtering Element: Combines active carbon pellet with syn- thetic fibers and microfibers with an efficiency of 95%, accor- PRODUCTS ding to EN 779, F7 and 85%, according EN779, M5. CONFOR Sealant: Polyurethane. Average Efficiency % (Em): 85% 4 EN 779 Class: F7. Recommended Fine Pressure Drop: 250 Pa. EPA/HEPA Temperature: Should not exceed 45ºC /ULPA Retention capacity: Organic substance toluene 952 g. 5 Organic substance n-Butane 117 g. Inorganic substance SO2 350 g. HIGH Inorganic substance HO2 5000 mg. TEMPERA- The retention capacity of the filter is determined for intake TURE concentrations, according to standard E DIN 71460/part 2 6 Accumulation Capacity: (AC Fine/450 Pa) 650 g. EQUIP- Advantages MENTS - Double action: A filtration F-7 class (EN 779: 2002) and adsorption of gases and odors in 7 a single filtering stage. MOTORS - Contaminants of low concentrations. AND - They don't rust and are incinerable 100%. - Interchangeable filters with pre-existing filter bags or compact filters. TURBINES OZONO PURIFICATION EFFICIENCY: 8 CAFP: 90% CAF: 70% ADSOR- TION AND References UxP (*) Stock DESODO- Units per box F: Manufacturer, S: Stock, SL: Limited Stock RIZATION Reference Model Dimensions Average EN 779 Filtering Carbon Rated flow Unit Weight UxP Stock 9 HxLxP Efficiency Class Area (kg) (m3/h / Pa) Vol. (m2) (m3) (Kg) * * INTER- 287x592x292 % (Em) F7 2,1 (m3/h / Pa) NATONAL CAFP122412F7 CAF 490x592x292 F7 4,3 3,6 2800/120 0,05 5,3 1 S NORMATI- CAFP202412F7 CAF 592x592x292 85% F7 7,5 4,4 3400/120 0,09 8,3 1 S CAFP242412F7 CAF 287x592x292 85% 9 2,1 1600/100 0,11 9,2 1 S VE CAF 490x592x292 85% 4,3 3,6 2400/100 0,05 5,3 1 F CAFP122412 CAF 592x592x292 7,5 4,4 3200/100 0,09 8,3 1 F CAFP202412 CAF 9 0,11 9,2 1 F CAFP242412 Venfilter 204 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com

Adsortion and desodorization Dimensions 0 Multicarb G INFORMA- TION Active Carbon Filters 1 Activated carbon filter multi-dihedral. PRE- Features techniques FILTERS Type: Compact activated carbon filter 2 Frame: Polypropylene. Filtering Element: Panels activated carbon grains. PAINTINGS Sealant: Polyurethane. BOOTHS Temperature: Should not exceed 45ºC. 3 Advantages PRODUCTS - Odor Absorption. CONFOR 4 References EPA/HEPA /ULPA Reference Model Dimensions Carbon Rated flow (m3/h Unit Vol. Weight UxP* Stock* HxLxP (Kg) / Pa) (m3) (Kg) 5 1 F CAFG122412GO CAFG 287x592x292 8 1700/70 0,05 13 1 F HIGH CAFG202412GO CAFG 490x592x292 12 2800/70 0,09 16 1 F TEMPERA- CAFG242412GO CAFG 592x592x292 16 3400/70 0,11 21 TURE UxP (*) Stock 6 Units per box F: Manufacturer, S: Stock, SL: Limited Stock EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 205 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Adsortion and desodorization INFORMA- Policarb TION Active Carbon Filters 1 Poly-dihedral active carbon filter with a Galvanized flat PRE- box with panels of granulated active carbon. FILTERS 2 Features techniques Dimensions PAINTINGS Type: Compact activated carbon filter. BOOTHS Frame: Galvanized Steel. Filtering Element: Active carbon dihedral panels. 3 Sealant: Polyurethane. Temperature: Should not exceed 45ºC. PRODUCTS CONFOR Advantages 4 - Odor absorption. - Special application: radioactive ions. EPA/HEPA /ULPA References 5 Reference Model Dimensions Carbon (Kg) Rated flow Unit Vol. Weight UxP* Stock* HxLxP (m3/h / Pa) (m3) (Kg) HIGH CAF112312GO CAF 10 1F TEMPERA- CAF232312GO CAF 290x595x292 20 1700/60 0,05 18 1F CAFISO232312 CAF-ISO 595x595x292 20 2800/60 0,11 24 1F TURE CAFISO112312 CAF-ISO 595x595x292 10 3400/80 0,11 30 1F 290x595x292 1700/80 0,05 18 6 UxP (*) Stock (*) other sizes: pleased consult. EQUIP- Units per box F: Manufacturer, S: Stock, SL: Limited Stock MENTS 7 MOTORS AND TURBINES 8 206 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com ADSOR- Fax +34 937 862 493 TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

International normative 0 International INFORMA- normative TION 1 PRE- FILTERS Historical Standards 2 PAINTINGS BOOTHS YEAR REFERENCE TYPE OF TEST CLASSIFICATION 3 1968 ASHRAE GRAVI-OPA 1980 GRAVI-OPA EU1 - EU4 / EU5 - EU9 PRODUCTS 1982 EUROVENT 4/5 GRAVI-OPA CONFOR 1993 AFNOR NF X 44.012 GRAVI-OPA G1 - G4 / F5 - F9 2003 G1 - G4 / F5 - F9 + Media descargada 4 CE EN 779 Gravimetric particles G1 - G4 / M5 - F9 Minimum efficiency 2012 CEN EN779:2002 EPA/HEPA 2016 Gravimetric particles ePM1, ePM2.5, ePM10 /ULPA 2017 CEN EN779:2012 Gravimetric particles ePM1, ePM2.5, ePM10 ISO 16890-1:2016 Gravimetric particles 5 ISO 16890-3:2017 HIGH Recommended minimum filter classes, by filter selection, depending on the type TEMPERA- of supply air and the outside air quality according to EN16798-3: 2017 TURE Exterior air Air supply class quality 6 SuP1 SuP2 SuP3 SuP4 SuP5 EQUIP- (más elevado) (más bajo) MENTS ODA 1 M5 + F7 F7 F7 F7 - 7 ODA 2 F7 + F7 M5 + F7 F7 F7 G3, M5 ODA 3 F7 + F9 F7 + F7 M6 + F7 F7 MOTORS F7 AND The new standard EN 16798-3: 2017 refers to the standard EN 779, does not provide any recommendation for TURBINES the selection of filters classified according to EN ISO 16890-1. 8 Venfilter [email protected] 207 Tel +34 937 862 607 www.venfilter.com ADSOR- Fax +34 937 862 493 TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 International normative INFORMA- EN 13053 If bag filters are used then the filtration zone must be TION Normative at least 10 m² per 1 m² of the equipment transversal section. The joints used must be of a closed cell type, 1 Air treatment ventilation. Filters installed in air treat- they must not absorb humidity and they must not form ment units. a nutritive substrate for micro-organisms. Permanent PRE- The first filtration stage must be placed on the air inlet fixing for the sealing must be guaranteed (for example, FILTERS side, as near as possible to the opening for the outdoor operation from the dirty air side). Filtration sections air inlet, so as to keep the air treatment elements as from an inside height of 1,6 m must be set up with an 2 clean as possible. Additional pre-filters G1 to G4 are inspection window (with a minimum interior diameter authorized. The second filtration stage is placed on the of 150 mm) and light inside. PAINTINGS outlet side at the start of the air supply duct to keep it In the fan section, for the purposes of setting the pres- BOOTHS clean. sure drop value in the filter on designing the air flow, When just one filtration stage is used for the supply this must be the average of the initial and final drops 3 system, the minimum that must be installed is a class for clean and dust filled filters respectively. F7 filter. Note 1: The volumetric flow variation of air due to dust PRODUCTS In the case of using a two filtration stages, the air su- accumulation must be indicated in the technical spe- CONFOR pply fan must be placed between the first and second cifications. If the specific tolerances for an application filtration stages. With the aim of preventing the deve- are not mentioned, <>10% is acceptable based on the 4 lopment of microbes in the second stage air filters or average pressure drop. in a superior stage, the relative humidity in the filter The pressure drops in a filter section that is filled with EPA/HEPA zone must be limited to 90%; temperatures below the solid particles must not exceed the values given in /ULPA dew point temperature must always be avoided. The air table 9. Lower pressure drops can also be specified filters must not be placed immediately after refrige- when appropriate. 5 ration batteries with dehumidification or after humidi- The filters installed in air treatment units used for hu- fiers (exception –steam humidifiers). man occupation must be tested and classified in accor- HIGH dance with the EN 779 Standard. TEMPERA- Maximum final pressure drop for filters TURE Class of filter Final pressure drop 6 G1 - G4 150 Pa EQUIP- M5 - F7 200 Pa MENTS F8 - F9 300Pa 7 Note 2: the final pressure drops indicated in the table for energy saving reasons are typical maximum values for working air treatment units and lower than those used in the EN 779 Standard for classification purposes, and the MOTORS performances obtained in the trials in accordance with the EN 779 Standard are not necessarily fulfilled with these AND lower pressure drops. The following data must be shown in a clearly visible way (with a label) in the filter section: class of filter, type of TURBINES filtering media, final pressure drop. On changing the filter the user must verify and update this information. 8 Venfilter ADSOR- Tel +34 937 862 607 [email protected] TION AND Fax +34 937 862 493 www.venfilter.com DESODO- 208 RIZATION 9 INTER- NATONAL NORMATI- VE

International normative 0 Equivalence of Standards for Controlled INFORMA- Rooms TION Equivalence of international classification standards 1 PRE- FILTERS No. of particles US Fed. Std 209E 1992 EN ISO 14644-1 France AFNOR NF European Union No. of particles 2 >0,5 µm/m³ 1996 X 44.101 1981 Pharmaceutical > 0,1 µm/m³ (aprox.) Industry Guide (approx.) PAINTINGS ISO 1 BOOTHS 1 ISO 2 BPF 1989 10 4 ISO 3 35 3 10 M1 1 ISO 4 4 000 A and B 100 35 M 1.5 10 ISO 5 350 PRODUCTS 100 M2 100 ISO 6 1 000 CONFOR 353 M 2.5 1 000 3 500 1 000 M3 10 000 10 000 4 3 530 M 3.5 100 000 35 000 10 000 M4 100 000 EPA/HEPA 35 300 M 4.5 350 000 /ULPA 100 000 M5 1 000 000 353 000 M 5.5 5 1 000 000 M6 ISO 7 400 000 C 3 530 000 M 6.5 HIGH 10 000 000 M7 ISO 8 4 000 000 D TEMPERA- 35 000 000 ISO 9 TURE BPF 1989 - Pharmaceutical Industry 6 Guide EQUIP- CLEAN ROOMS MENTS Classification of the different air qualities required to manufacture sterile products: 7 Maximum Nº of particles per m3 of air, with a dimension equal or superior to Max. Nº of microor- MOTORS ganisms per m3 of air AND 0.5 µm 5 µm 0.5 µm 5 µm (in activity) TURBINES In non-activity (b) In activity 8 A 3500 0 3500 0 <1 ADSOR- B 3500 0 350000 2000 10 TION AND DESODO- C 350000 2000 3500000 20000 100 RIZATION D 3500000 20000 not defined (c) not defined (c) 200 9 Venfilter [email protected] 209 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE

0 International normative INFORMA- TION Clean rooms and controlled annexed 1 premises (US.FED.STD.209E) PRE- FILTERS 2 Class name Class limits PAINTINGS 0,1 μm 0,2 μm 0,3 μm 0,5 μm 0,5 μm BOOTHS S1 English mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ 3 M1 1 350 9,91 75,5 21,4 30,9 0,875 10 0,288 M 1,5 10 1240 335 265 7,5 106 3 35,3 1 247 7 PRODUCTS M2 100 3500 99,1 757 21,4 309 8,75 100 2,83 618 17,5 CONFOR M 2,5 12499 360 2650 75 1060 30 353 10 2470 70 M3 35000 991 7570 214 3090 87,5 1000 28,3 6180 175 4 M 3,5 26500 750 10600 300 3530 100 24700 700 M4 75700 2140 30900 875 10000 283 61800 1750 EPA/HEPA M 4,5 35300 1000 /ULPA M5 1000 100000 2830 M 5,5 353000 100000 5 M6 10000 1000000 28300 M 6,5 3530000 100000 HIGH M7 100000 10000000 283000 TEMPERA- EN ISO 14644 Standard TURE Classes by type of air particle cleaning for clean rooms and protected zones. 6 Classification Maximum admissible concentration (particles per m3 of air) for particle dimensions equal or superior to: EQUIP- Number MENTS 0,1 0,2 0,3 0,5 1 5 ISO CD 14644.1 10 2 7 (1996) 100 24 10 4 8 29 1000 237 102 35 83 293 MOTORS ISO 1 10000 2370 1020 352 832 2930 AND ISO 2 100000 23700 10200 3520 8320 29300 ISO 3 1000000 237000 102000 35200 83200 293000 TURBINES ISO 4 352000 832000 ISO 5 3520000 8320000 8 ISO 6 35200000 ISO 7 ADSOR- ISO 8 TION AND ISO 9 DESODO- RIZATION Venfilter 9 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com INTER- 210 NATONAL NORMATI- VE