Adsortion and desodorization 0Nitropropane A Persistent odors A Trichlorethylene A INFORMA-Nonane A Stale odors A Sulphur trioxide * B TIONOctalene A Ethylene oxide B Turpentine AOctane A Mesityl oxide A Urea A 1Odorizes A Ozone A Tarmac fumes AGarlic smell A Paradichlorobenzene A Varnish fumes A PRE-Animal odor B B Adhesives A Fuel fumes C FILTERSSmell of dead animals A Pentane B Diesel fumes ASmell of roast meat A Pentanone A Exhaust fumes B G2-G4Onion smell A Pen ethylene * B Vinegar ASour cabbage smell A Pentene * B B Xylene A 2Smell of decomposed food A Perchlorethylene A Iodine ASmell of burnt food A Perfumes and cosmetics A Iodoform A PAINTINGSOdor of rubber A Pyridine A Hydrogen Iodide * B BOOTHSSmell of cigarette smoke A Pollen B 199 3Venfilter [email protected] +34 937 862 607 www.venfilter.com PRODUCTSFax +34 937 862 493 CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 Adsortion and desodorizationINFORMA- Pellets Carbon TION Active Carbon Filters1 Active carbon pellets, supplied in bags. Highly efficient filtra- PRE- tion for the elimination of gaseous pollutants substances. With FILTERS a wide variety of options. Central air filtration of systems for the elimination of gaseous pollutants. Air treatment units, Hospital G2-G4 centers, pharmaceutical laboratories, comfort and industrial facilities, chemical and food industry. Incineration / Niches /2 Water treatment plants, dead animal deposits, hotels, restau- rants, discotheques, thermal and nuclear power plants, mu-PAINTINGS seums, theaters, computer rooms, critical areas. BOOTHS Features techniques3 Type: Active Carbon FiltersPRODUCTS Filtering element: Active pellet carbon or with impregnations for the filtration of very specific gases, (acid CONFOR vapors, isotopes radio, chlorine, formaldehyde, mercury, etc.) Supplied in bags of 25 kg. M5-F9 Advantages4 Filtration of central ventilation systems, for the elimination of gaseous pollutants.EPA/HEPA High efficiency filters can not cope with the problems of contamination by volatile or gaseous substances. /ULPA Active carbon filters improve air quality, alleviating the discomfort of people produced by the “Sick Building” Syndrome by eliminating polluting gases and odors in urban environments that enter the offices through the5 ventilation system through a chemical-physical process. HIGH ReferencesTEMPERA- Reference Model Presentation Granulometry Density gr./l Humidity Hardness Sup. Ind. Adsorption TURE mm. % % Esp. Iodine CCL4 % 0,48+-0,03 m2/gr. Mg / gr.6 CARB-4/25 CARB Pellet 4 0,50 5 97 55 CARB-ORGANICO CARB Pellet 8 x 30 4 98 900 950 50 EQUIP- CARB-FORMALDEHIDO CARB Pellet 4 x 10 0,52-0,58 4 98 700 min. 700 50 MENTS CARB Pellet 4 x 10 0,52-0,58 10 98 1000 50 CARB-ACIDO CARB Pellet 4 x 10 0,52-0,58 4 98 1000 507 CARB-AMONIACO CARB Granulated 0,45+-0,02 10 97 1000 65 CARB-ISOTOPOS 14 1000 1000 MOTORS 1000 1000 AND 1000TURBINES UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock8 Venfilter ADSOR- TION AND 200 Tel +34 937 862 607 [email protected] DESODO- Fax +34 937 862 493 www.venfilter.com RIZATION9 INTER- NATONALNORMATI- VE

Adsortion and desodorization NEW 0Quebraven Galvanized INFORMA-Impregnated carbon TIONActive Carbon Filters 1Panel filter with metal frame with filter media impregna- PRE-ted with active carbon. For the prefiltration of central air FILTERStreatment, conditioning and ventilation systems for theelimination of gaseous pollutants. G2-G4Features techniques 2Type: Panel filter with metal frame with filter media impreg- PAINTINGSnated with active carbon. BOOTHSFrame: Galvanized steel.Grid: Metallic galvanized on both sides. Dimensions 3Filter element: Synthetic media impregnated with activatedcarbon. PRODUCTSRelative Humidity: 70%. CONFORTemperature limit: 55ºC. M5-F9Advantages 4- Combined particles / molecules filtration. EPA/HEPA- Low losses. /ULPA- All dimensions. 5References HIGH TEMPERA- TUREReference Model Dimensions Filtering Rated flow Unit Vol. UxP* Stock* 6 HxLxP Area (m2) (m3/h / Pa) (m3)QM122402CA Quebraven Metálico Carbón 1F EQUIP-QM122404CA Quebraven Metálico Carbón 287x592x48 0.7 1500/125 0.008 1F MENTSQM242402CA Quebraven Metálico Carbón 287x592x98 1.1 1700/195 0.016 1FQM242404CA Quebraven Metálico Carbón 592x592x48 1.3 3000/125 0.016 1F 7 592x592x98 2.2 3400/95 0.034 MOTORS UxP (*) Stock (*) other sizes: pleased consult. ANDUnits per box F: Manufacturer, S: Stock, SL: Limited Stock TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 201 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Adsortion and desodorization DimensionsINFORMA- Frame for carbon TION replaceable cartridge1 Active Carbon Filters PRE- Frame for fitting the active carbon cylinders. FILTERS Features techniques G2-G4 Type: Mounting for the cartridges.2 Frame: Galvanized Steel, Stainless Steel or Plastic. Cartridge Fitting system: Fitting of cartridges on thePAINTINGS quick bayonet mounting. BOOTHS Advantages3 - Modular System.PRODUCTS CONFOR References M5-F9 Reference Model Dimensions No. of Unit Vol. Weight (Kg) UxP Stock4 LxHxP Cartridges (m3) * * BTCGV1224 BTC-GV 3EPA/HEPA BTCGV2424 BTC-GV 305x610x75 8 0.02 5 1 F /ULPA 610x610x75 16 0.03 1 F5 UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock HIGHTEMPERA- Venfilter TURE 202 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE

Adsortion and desodorization 0 Replaceable carbon INFORMA- cartridges TION Active Carbon Filters 1Replaceable carbon cartridges for air entry and exit in Dimensions PRE-ventilation systems that require imporved odor absorption, FILTERSVOCs and the elimination of gases with low toxicity levels. G2-G4Features techniques 2Type: Active carbon cylindrical cartridge.Carbon: Impregnated Active Carbon. PAINTINGSJoint: Neoprene. BOOTHSTemperature: Should not exceed 45ºCRelative Humidity: Maximum 70% 3Contact time: According to the application it can vary from0.1 to 0.2 seconds. PRODUCTSCALCULATION OF CONTACT TIME: Ct (sec.) = volume of CONFORactive carbon (m3) / flow to be treated m3/h seconds. M5-F9ExampleFrame BTCGV2424 is fitted with 16 cartridges. 4Cartridge CACGV145/450 contains 4.3 kg.Volume of carbon = 16 x 4.3 = 68.8 liters or 0.0688 m3/h EPA/HEPAFlow to be treated in the installation 1,200 m3h /ULPACALCULATIONCt(sec.) = 0.0688 / 1200 x 3600 = 0.2 seconds 5The contact time is 0.2 seconds, the flows would be as HIGHfollows: TEMPERA-CACGV145/250 - 50 m3/h per cartridgeCACGV145/450 - 75 m3/h per cartridge TURECACGV145/600 - 100 m3/h per cartridge 6Advantages EQUIP-- Reloadable cartridges with granulated active carbon. MENTS- Moludar system for adaptation to any installation. 7References UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock MOTORS ANDReference Model Diameters Carbon Carbon (Kg) Minimum Rated flow(m3/h UxP Stock (mm) Thickness contact TURBINES 2,9 time (s) / Pa) ** 26 mm. 4,3 8CACGV145/250 CAC-GV 145x85x250 26 mm. 5,7 0,1 100/80 1FCACGV145/450 CAC-GV 145x85x450 26 mm. 0,1 150/80 1F ADSOR-CACGV145/600 CAC-GV 145x85x600 0,1 200/80 1F TION AND DESODO- Venfilter [email protected] 203 RIZATION Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 9 INTER- NATONAL NORMATI- VE

0 Adsortion and desodorizationINFORMA- Multicarb TION Active Carbon Filters1 Multi-dihedral carbon filter with half fold and active PRE- carbon. FILTERS Features techniques Dimensions G2-G4 Type: Compact Polyhedral Rigid Bag Filter for deodorisation2 associated with a High Efficiency filter. Frame: Polypropylene.PAINTINGS Filtering Element: Combines active carbon pellets with syn- BOOTHS thetic fibers and microfibers with an efficiency of 95%, accor- ding to EN 779, F7 and 85%, according EN779, M5.3 Sealant: Polyurethane. Average Efficiency % (Em): 85%PRODUCTS EN 779 Class: F7. CONFOR Recommended Fine Pressure Drop: 250 Pa. M5-F9 Temperature: Should not exceed 45ºC Retention capacity:4 Organic substance toluene 952 g. Organic substance n-Butane 117 g.EPA/HEPA Inorganic substance SO2 350 g. /ULPA Inorganic substance HO2 5000 mg.5 The retention capacity of the filter is determined for intake concentrations, according to standard E DIN 71460/part 2 HIGHTEMPERA- Accumulation Capacity: (AC Fine/450 Pa) 650 g. TURE Advantages6 - Double action: A filtration F-7 class (EN 779: 2002) and adsorption of gases and odors in EQUIP- a single filtering stage. MENTS - Contaminants of low concentrations. - They don't rust and are incinerable 100%.7 - Interchangeable filters with pre-existing filter bags or compact filters. MOTORS OZONO PURIFICATION EFFICIENCY: AND CAFP: 90% CAF: 70%TURBINES References UxP (*) Stock8 Units per box F: Manufacturer, S: Stock, SL: Limited Stock ADSOR- Reference Model Dimensions Average EN 779 Filtering Carbon Rated flow Unit Weight UxP Stock TION AND HxLxP Efficiency Class Area (kg) (m3/h / Pa) Vol. DESODO- (m2) (m3) (Kg) * * RIZATION 287x592x292 % (Em) F7 2,1 (m3/h / Pa) CAFP122412F7 CAF 490x592x292 F7 4,3 3,6 2800/120 0,05 5,3 1 S9 CAFP202412F7 CAF 592x592x292 85% F7 7,5 4,4 3400/120 0,09 8,3 1 S CAFP242412F7 CAF 287x592x292 85% 9 2,1 1600/100 0,11 9,2 1 S INTER- CAF 490x592x292 85% 4,3 3,6 2400/100 0,05 5,3 1 F NATONAL CAFP122412 CAF 592x592x292 7,5 4,4 3200/100 0,09 8,3 1 FNORMATI- CAFP202412 CAF 9 0,11 9,2 1 F CAFP242412 VE Venfilter 204 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com

Adsortion and desodorization 0Multicarb G INFORMA- TIONActive Carbon Filters 1Activated carbon filter multi-dihedral. PRE-Features techniques FILTERSType: Compact activated carbon filter G2-G4Frame: Polypropylene.Filtering Element: Panels activated carbon grains. 2Sealant: Polyurethane.Temperature: Should not exceed 45ºC. PAINTINGS BOOTHS Dimensions 3Advantages PRODUCTS CONFOR- Odor Absorption. M5-F9References 4Reference Model Dimensions Carbon Rated flow (m3/h Unit Vol. Weight UxP* Stock* EPA/HEPA HxLxP (Kg) / Pa) (m3) (Kg) /ULPA 1 F 287x592x292 8 1700/70 0,05 13 1 F 5 490x592x292 12 2800/70 0,09 16 1 FCAFG122412GO CAFG 592x592x292 16 3400/70 0,11 21 HIGHCAFG202412GO CAFG TEMPERA-CAFG242412GO CAFG TURE UxP (*) Stock 6 Units per box F: Manufacturer, S: Stock, SL: Limited Stock EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 205 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Adsortion and desodorizationINFORMA- Policarb TION Active Carbon Filters1 Poly-dihedral active carbon filter with a Galvanized flat PRE- box with panels of granulated active carbon. FILTERS Features techniques Dimensions G2-G4 Type: Compact activated carbon filter.2 Frame: Galvanized Steel. Filtering Element: Active carbon dihedral panels.PAINTINGS Sealant: Polyurethane. BOOTHS Temperature: Should not exceed 45ºC.3 AdvantagesPRODUCTS - Odor absorption. CONFOR - Special application: radioactive ions. M5-F9 References4 Reference Model Dimensions Carbon (Kg) Rated flow Unit Vol. Weight UxP* Stock*EPA/HEPA HxLxP (m3/h / Pa) (m3) (Kg) /ULPA CAF112312GO CAF 10 1F CAF232312GO CAF 290x595x292 20 1700/60 0,05 18 1F5 CAFISO232312 CAF-ISO 595x595x292 20 2800/60 0,11 24 1F CAFISO112312 CAF-ISO 595x595x292 10 3400/80 0,11 30 1F HIGH 290x595x292 1700/80 0,05 18TEMPERA- UxP (*) Stock (*) other sizes: pleased consult. TURE Units per box F: Manufacturer, S: Stock, SL: Limited Stock6 Venfilter EQUIP- 206 Tel +34 937 862 607 [email protected] MENTS Fax +34 937 862 493 www.venfilter.com7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE

International normative 0 International INFORMA- normative TION Historical Standards 1 PRE- FILTERS G2-G4 2 PAINTINGS BOOTHSYEAR REFERENCE TYPE OF TEST CLASSIFICATION 31968 ASHRAE GRAVI-OPA1980 GRAVI-OPA EU1 - EU4 / EU5 - EU9 PRODUCTS1982 EUROVENT 4/5 GRAVI-OPA CONFOR1993 AFNOR NF X 44.012 GRAVI-OPA G1 - G4 / F5 - F9 M5-F92003 G1 - G4 / F5 - F9 + Media descargada CE EN 779 Gravimetric particles G1 - G4 / M5 - F9 Minimum efficiency 42012 CEN EN779:20022016 Gravimetric particles ePM1, ePM2.5, ePM10 EPA/HEPA2017 CEN EN779:2012 Gravimetric particles ePM1, ePM2.5, ePM10 /ULPA ISO 16890-1:2016 Gravimetric particles ISO 16890-3:2017 5Recommended minimum filter classes, by filter selection, depending on the type HIGHof supply air and the outside air quality according to EN16798-3: 2017 TEMPERA- Exterior air Air supply class TURE quality SuP1 SuP2 SuP3 SuP4 SuP5 6 (más elevado) (más bajo) EQUIP- MENTS ODA 1 M5 + F7 F7 F7 F7 - ODA 2 F7 + F7 M5 + F7 F7 F7 G3, M5 7 ODA 3 F7 + F9 F7 + F7 M6 + F7 F7 F7 MOTORS ANDThe new standard EN 16798-3: 2017 refers to the standard EN 779, does not provide any recommendation forthe selection of filters classified according to EN ISO 16890-1. TURBINES Venfilter [email protected] 207 8 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 International normativeINFORMA- EN 13053 If bag filters are used then the filtration zone must be TION Normative at least 10 m² per 1 m² of the equipment transversal section. The joints used must be of a closed cell type,1 Air treatment ventilation. Filters installed in air treat- they must not absorb humidity and they must not form ment units. a nutritive substrate for micro-organisms. Permanent PRE- The first filtration stage must be placed on the air inlet fixing for the sealing must be guaranteed (for example, FILTERS side, as near as possible to the opening for the outdoor operation from the dirty air side). Filtration sections air inlet, so as to keep the air treatment elements as from an inside height of 1,6 m must be set up with an G2-G4 clean as possible. Additional pre-filters G1 to G4 are inspection window (with a minimum interior diameter authorized. The second filtration stage is placed on the of 150 mm) and light inside.2 outlet side at the start of the air supply duct to keep it In the fan section, for the purposes of setting the pres- clean. sure drop value in the filter on designing the air flow,PAINTINGS When just one filtration stage is used for the supply this must be the average of the initial and final drops BOOTHS system, the minimum that must be installed is a class for clean and dust filled filters respectively. F7 filter. Note 1: The volumetric flow variation of air due to dust3 In the case of using a two filtration stages, the air su- accumulation must be indicated in the technical spe- pply fan must be placed between the first and second cifications. If the specific tolerances for an applicationPRODUCTS filtration stages. With the aim of preventing the deve- are not mentioned, <>10% is acceptable based on the CONFOR lopment of microbes in the second stage air filters or average pressure drop. M5-F9 in a superior stage, the relative humidity in the filter The pressure drops in a filter section that is filled with zone must be limited to 90%; temperatures below the solid particles must not exceed the values given in4 dew point temperature must always be avoided. The air table 9. Lower pressure drops can also be specified filters must not be placed immediately after refrige- when appropriate.EPA/HEPA ration batteries with dehumidification or after humidi- The filters installed in air treatment units used for hu- /ULPA fiers (exception –steam humidifiers). man occupation must be tested and classified in accor- dance with the EN 779 Standard.5 Maximum final pressure drop for filters HIGHTEMPERA- Class of filter Final pressure drop TURE G1 - G4 150 Pa M5 - F7 200 Pa6 F8 - F9 300Pa EQUIP- Note 2: the final pressure drops indicated in the table for energy saving reasons are typical maximum values for MENTS working air treatment units and lower than those used in the EN 779 Standard for classification purposes, and the performances obtained in the trials in accordance with the EN 779 Standard are not necessarily fulfilled with these7 lower pressure drops. The following data must be shown in a clearly visible way (with a label) in the filter section: class of filter, type of MOTORS filtering media, final pressure drop. On changing the filter the user must verify and update this information. AND VenfilterTURBINES Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 208 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE

International normative 0Equivalence of Standards for Controlled INFORMA-Rooms TIONEquivalence of international classification standards 1 PRE- FILTERS G2-G4No. of particles US Fed. Std 209E 1992 EN ISO 14644-1 France AFNOR NF European Union No. of particles 2 >0,5 µm/m³ 1996 X 44.101 1981 Pharmaceutical > 0,1 µm/m³ (aprox.) Industry Guide (approx.) PAINTINGS ISO 1 BOOTHS 1 ISO 2 BPF 1989 10 4 ISO 3 35 3 10 M1 1 ISO 4 4 000 A and B 100 35 M 1.5 10 ISO 5 350 PRODUCTS 100 M2 100 ISO 6 1 000 CONFOR 353 M 2.5 1 000 3 500 M5-F9 1 000 M3 10 000 10 000 3 530 M 3.5 100 000 35 000 4 10 000 M4 100 000 35 300 M 4.5 350 000 EPA/HEPA 100 000 M5 1 000 000 /ULPA 353 000 M 5.5 1 000 000 M6 ISO 7 400 000 C 5 3 530 000 M 6.5 10 000 000 M7 ISO 8 4 000 000 D HIGH 35 000 000 TEMPERA- ISO 9 TUREBPF 1989 - Pharmaceutical IndustryGuide 6 EQUIP- MENTSCLEAN ROOMS 7Classification of the different air qualities required to manufacture sterile products: MOTORS Maximum Nº of particles per m3 of air, with a dimension equal or superior to Max. Nº of microor- AND ganisms per m3 of air 0.5 µm 5 µm 0.5 µm 5 µm TURBINES (in activity) In non-activity (b) In activity <1 8 10A 3500 0 3500 0 100 ADSOR- 200 TION ANDB 3500 0 350000 2000 DESODO- 209 RIZATIONC 350000 2000 3500000 20000 9D 3500000 20000 not defined (c) not defined (c) INTER- Venfilter [email protected] NATONAL Tel +34 937 862 607 www.venfilter.com NORMATI- Fax +34 937 862 493 VE

0 International normativeINFORMA- Clean rooms and controlled annexed TION premises (US.FED.STD.209E)1 Class name Class limits PRE- 0,1 μm 0,2 μm 0,3 μm 0,5 μm 0,5 μm FILTERS S1 English mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ G2-G4 M1 1 350 9,91 75,5 21,4 30,9 0,875 10 0,288 M 1,5 10 1240 335 265 7,5 106 3 35,3 1 247 72 M2 100 3500 99,1 757 21,4 309 8,75 100 2,83 618 17,5 M 2,5 12499 360 2650 75 1060 30 353 10 2470 70PAINTINGS M3 35000 991 7570 214 3090 87,5 1000 28,3 6180 175 BOOTHS M 3,5 26500 750 10600 300 3530 100 24700 700 M4 75700 2140 30900 875 10000 283 61800 17503 M 4,5 35300 1000 M5 1000 100000 2830PRODUCTS M 5,5 353000 100000 CONFOR M6 10000 1000000 28300 M5-F9 M 6,5 3530000 100000 M7 100000 10000000 2830004 EN ISO 14644 StandardEPA/HEPA /ULPA Classes by type of air particle cleaning for clean rooms and protected zones.5 Classification Maximum admissible concentration (particles per m3 of air) for particle dimensions equal or superior to: Number HIGH 0,1 0,2 0,3 0,5 1 5TEMPERA- ISO CD 14644.1 10 2 (1996) 100 24 10 4 8 29 TURE 1000 237 102 35 83 293 ISO 1 10000 2370 1020 352 832 29306 ISO 2 100000 23700 10200 3520 8320 29300 ISO 3 1000000 237000 102000 35200 83200 293000 EQUIP- ISO 4 352000 832000 MENTS ISO 5 3520000 8320000 ISO 6 352000007 ISO 7 ISO 8 MOTORS ISO 9 AND VenfilterTURBINES Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 210 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE

Edition: JULY 2018


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook