TRANSFORMER
TRANSFORMERAre you looking for a reliable business partner in the energy sector?Do you want clean energy and happy tomorrows?Is Both Reasonable price and Quality Impossible?Can’t you find Fast Service and after sales support? STRONG PARTNER IN THE TRANSFORMER INDUSTRY CONTACT US
TRANSFORMERCompany ProfileSBS Transformer that in order to use its high level of experience and knowledge in the energy sector, by combining its experienced staff with inno-vative, high quality and analytical production principles, has been established in Kayseri at the beginning of 2016 with the advantages of centrallogistics that has 2000 square meters closed and 3000 square meters open area suitable for development and expansion.Despite being a newly established company, we have set up our system quickly and very successfully and in line with the standards required by thetimes; and we have taken ISO 9001: 2000 Quality System, ISO 14001 Environmental Management System and Certification of manufacturing com-petency according to TSE Standards.Our company, which has worked with the electricity market all over Turkey, has recently established a special sales team and technical infrastructurefor foreign trade. Our company; It is aimed to represent itself and the country in the best way and to be successful in the foreign platform and to createincome and employment fields.Our company; that with experienced staff and specialist subcontractor capacity, about on installation, maintenance and repair of on-site transformersand MV systems, aims to be number one in the country in a short time.Our constantly developing company will continuously target to fulfill customer satisfaction with the principle of producing in modern levels that arein line with the requirements of technology.Our Quality PolicyOur main policy is that respond to customers’ timely delivery, high quality and price appropriateness expectations in the direction of our vision andmission while using continuously developing and up-to-date Technologies. While developing reliable products that provide ease of use, provide thesame quality of service for after-sales• Execution of Quality Management System• Continuous process, quality and performance checks• Continuous improvement and continuity of AR-GE work• Innovative and eco-friendly• Prone to produce energy-saving products for the world and the human future• Not compromising environment, work and worker healthOur VisionAbout manufacturing and installation issues in national and international markets, to be a reputable, trustworthy and promising organization in thesector that can give direction in quality and price.Our MissionTo create balances in the energy sector and the energy market, always to produce quality, reliable and appropriate products; Maintain and improvethe influence in the market without sacrificing quality and customer satisfaction; Provide after-sales service satisfaction at the top level; To be a hu-man and environment friendly organization.
TRANSFORMER Products 1.Distribution Transformers 1.1.Hermetic Type Distribution Transformers 1.2.Conserator Type Distribution Transformers 2.Power Transformers 3. Special Type Transformers 4. MV Switching Equipment
TRANSFORMERHermetic Type Distribution TransformersTechnicial Specifications:Power Range : All standard and intermediate powers from 25 kVA to 2500 KvaVoltage Range : At all voltage levels 0-36 kVNumber of Phase : 1 phase or 3 phase optionsTapchanger Type : Idle and on-load tap-changerCooling Type : ONAN or ONAFPlace of Use : In Internal or External areasLost Class : Standard production class A(AoAk); According to optional customer requirementsConductor Type : Aluminum or copperTerminal Type : Porcelain insulated, Plug-in, With cable box, With side exitStructure of Transformer;It is designed to be fully enclosed from the atmosphere. The internal pressure of thetransformer is adjusted during oil printing using special equipment. When the trans-former is overloaded, the volume expansion of the insulating fluid(oil) heated due tothermal effects is throttled on the boiler of the wave wall structure, which has the elasticstructure and also performs the cooling function. The oil is printed in special vacuumchambers so that the transformer can be completely filled with oil(no air). The core andcoil structure are the same as the expansion storage transformer.Advantages• Because it is closed from the atmosphere, insulating oil does not penetrate withoxygen and the insulation deterioration caused by oxidation does not exist. The life ofthe transformer in terms of insulation; And therefore the life expectancy of the trans-former is extended.• It does not require periodic maintenance in normal conditions and under usageexcept cleaning• Dimensionally reduced height as there is no expansion tank. This is an advan-tage in transformer centers where the height is a problem.
TRANSFORMERConservator Type TransformerTechnicial Specifications:Power Range : All standard and intermediate powers from 25 kVA to 2500 KvaVoltage Range : At all voltage levels 0-36 kVNumber of Phase : 1 phase or 3 phase optionsTapchanger Type : Idle and on-load tap-changerCooling Type : ONAN or ONAFPlace of use : In Internal or External areasLost class : Standard production class A(AoAk); According to optional customer requirementsConductor Type : Aluminum or copperTerminal type : Porcelain insulated, Plug-in, With cable box, With side exitStructure of Transformer;It is designed to be open from the atmosphere. It does not require any pressure setting.Only Insulation oil level adjustment is necessary.The expansion tank is designed according to the maximum expansion of the insula-tion oil and when filling is done, the level is adjusted according to this amount ofexpansion. Air exchange against humidity; Through an air drier which changes itshumidity when it receives the humidity.AdvantagesThere isn’t dangerous pressure will be generated in the transformer in any way.Therefore, pressure problems will not occur in overload.Deformation in the metal will be less because there is no expansionIt has a more suitable structure for on-site maintenance / repair.
TRANSFORMERPower TransformersTechnicial Specifications:Power Range : All standard and intermediate powers from 2,5 MVA to 25MVAVoltage Range : At all voltage levels 20-36 kVNumber of Phase : 1 phase or 3 phase optionsTapchanger Type : Idle and on-load tap-changerCooling Type : ONAN or ONAFPlace of use : In Internal or External areasLost class : According to customer requirementsConductor Type : CopperTerminal type : Porcelain insulated, With cable box, With side exitStructure of Transformer;It is generally designed as Conservator Type. As cooling elements radiator groupsthat can be installed and removed are preferred. It is equipped with more protectionequipments compared to Distribution Transformers according to usage place andimportance.Special Type TransformersPower Range : All standard and intermediate powers from 25 kVA to 2500 KvaVoltage Range : At all voltage levels 0-36 kVNumber of Phase : 1 phase or 3 phase optionsLevel Type : Idle and on-load tap-changerCooling Type : ONAN or ONAFPlace of use : In Internal or External areasLost class : According to customer requirementsConductor Type : Aluminum or copperTerminal type : According to customer requirementsStructure of Transformer;We meet special type transformer needs that can meet all new and changing needs ofour customers in industry, distribution and all other fields. Our technical team whoworks by mutual consultation with each customer, listening to all kinds of needs andrecommendations, meets the need by projecting it immediately and implementing it.MV Switching EquipmentWe provide all kinds of MV and LV switchgear supplies.Contact us to get an offer ...
TRANSFORMERAuxiliary EquipmentHermetic Relay:It is a protective equipment that usually used in hermetic transformers. It is used in stan-dard demands at 630 kVA and above, but it can also be used for all internal type trans-formers in the direction of customer demand. It is mounted at the top of the transformer.It measures and controls 4 parameters in the tank; • Transformer upper oil temperature • Pressure that generated in the transformer • Oil level • The amount of gas that can be generated by faults and dischargesThere are 2 contacts according to the values that can be set for the temperature. it canbe used as a trip and warning. 1 contact is available depending on the values that can beset for pressure. It is used for opening. The oil level and gas formation are functionallycontrolled in the same way. Therefore, there is 1 contact for both. It is used for opening.Buchholz Relay:Buchholz relay is a type of oil and gas actuated protection relay universally used onall oil immersed transformers having rating more than 500 kVA. Buchholz relay is notprovided in relays having rating below 500 kVA from the point of view of economic con-siderations.Buchholz relay is used for the protection of transformers from the faults occurring insidethe transformer. Short circuit faults such as inter turn faults, incipient winding faults,and core faults may occur due to the impulse breakdown of the insulating oil or simplythe transformer oil. Buchholz relay will sense such faults and closes the alarm circuit.Thermometer:It is a protective device that usually mounted on the cover for measuring and controllingthe upper oil temperature of the transformer. On the thermometer there is a resettablemaxigraf that continuously displays the maximum temperature. It can be used with orwithout contact. Contact thermometers have 1 or 2 adjustable contacts (as a warningand trip).
TRANSFORMEROil Level Indicator:It is a protective equipment that used to measure and control the level of the isolationoil in the transformer. In conservator type transformer it is mounted on the side coverof the expansion tank, in hermetic type transformers it is mounted on the cover. It canbe used with or without contact. Contact thermometers have 1 or 2 adjustable contacts(as a warning and trip).Pressure Relief Valve:It is generally used in hermetic transformers. It detects sudden or wide-time pressureincreases that may occur due to oil temperature expansion or failure in the transformer,evacuates the pressure. It can be used with or without contact. Contacted Pressure reliefvalves have 1 or 2 adjustable contacts (as warning and trip).Air Dryer:It is generally used in conservator type transformer. It throws out the air that expandsand shrinks with temperature changes in the transformer oil and gets back the air again.With the silica gel dehumidifier it keeps on a large part of the humidity of the passingair. Thus reducing the possibility of moisture in the insulation oil. Silica gel must bechanged when the color is turned white. It is mounted at the uppermost point of the ex-pansion tank which is not in contact with oil.WHEELBy mounting the transformer in the lower transport case, the transport of the heavygoods is facilitated. Transformer wheels can move in only 4 directions with 90 degreesdifference. A transformer is fitted with 4 wheels.
TRANSFORMERPRODUCTION STAGESDESIGNDesigns are made with programs that we have developed in our company with our own license and experienced technical cadre. With reference tothe customer requests, our project team follows the order from the proposal stage to the order and delivery stage meticulously. Every step of designand implementation is approved by the customer. Rigorous and realistic work at the proposal stage removes the return in production or design. Ourdesign team obtains all the information about the place and conditions of work and guides the client not to make the wrong choices.COREAs a magnetic circuit element, the core is manufactured in high quality, oriented, cold rolled, low loss and insulated on both sides. According to thedesign inputs, the project is made using 0,23 - 0,27 - 0,30 mm thickness and various specifications of sheet metal. According to the technical details ofthe project, the magnetic circuit is made by cutting and arranging. The parts that carrying the windings are called leg, the parts that joining the legsfrom the top and the bottom are called yokes. The yoke part is compressed by a metal part and the vibrations are destroyed.
TRANSFORMERWINDINGSThere are two main sections in distribution transformers. These are Low Voltage (LV) windings and High Voltage (HV) windings. Since the voltageof the LV winding is low and the current is high, high-section conductors are used, it is usually wrapped for insulation purposes near the core. Sincethe voltage of the HV winding is high and the current is low, smaller-sized conductors are used, it is wound on top of the general LV coil. Conductorsare selected from electrolytic copper and aluminum materials with high conductivity and high purity. As a insulation, intensity has been increased,insulation values are too high, mechanically resistant, oil resistant and European origin insulation materials are used. Coil losses, overload loadsand cooling calculations are made, designed and according to the project, windings are made.COVER AND BOILERTransformer caps are made of high quality st-37, st-52 steel materials. According to the project, terminal outlets and protection; If the observationequipment is available the expansion tank is manufactured by mounting the mount point and lifting ears. According to the magnitude of the currentflowing through the terminals, the phase-to-phase or phase-to-neutral current loop is reinforced with antimagnetic sheet. to avoid extra heating of thecover sheet. Cover welds are made with sealing welding technique and it is shipped to assembly after the leak checks are done.The transformer boiler is made of high-quality st-37, st-52, and radiator as cooling group or wave wall sheets with elastic properties. Wave wall orradiator sheets are used as 102 mm or 1,5 mm. All equipment is assembled according to the Project. The boiler welds are made with a very specialsealing welding technique like by welding thin sheet on thick sheet. After manufactured, the penetration fluid is bored and pressure is applied to theboiler, In the dark, leakage control is done with black light and then shipped to assembly.
TRANSFORMERASSEMBLYCoils are passed to the core legs. After the core yoke piece sequence is made andthe magnetic circuit is closed, the bobbins are clamped with insulating wedges andcore yoke bars, it is fixed to resist for the calculated short-circuit forces. The core isphysically mounted on the cover with coils and the active part is formed. Accordingthe process after the active part is tested for insulation distances before or after thedrying process, the assembly steps are carried out and it is shipped to the oilingpress process.OVEN AND OIL PRESSINGAs it is known, it is very important to take the moisture for the insulation life ofthe transformer. Transformers whose active part is assembled are fired at 105-110degrees in the furnaces where the heat distribution is equal and can reach high vac-uum levels. At the beginning and end of the firing process, insulation is measuredand the firing is controlled. The transformers which are fired and boiler assembledare again subjected to oil pressing under high vacuum. Generally nematic mineraloils, that is strengthened in terms of temperature and insulation resistance, are used.In addition, herbal or nonflammable oils can also be used. The oil level settings ofthe expansion storage transformers are made, the special pressure settings of thehermetic transformers are made too and the process is terminated.
TRANSFORMERProduct Quality ControlTransformers are shipped to the next procedure, by are made either physically andelectrically measurements, in all stages of production. It is not possible to completethe process without measurement, control and approval of production quality controlpersonel. Possible problems and failures are examined and revealed at the earliestpossible stages.Tests and Measurements applied to Semi Finished Goods: • Dimension Measurements • Conversion Rates Measurements • Insulation Resistance Measurements • DC Resistance Measurements • Impermeability ControlsRoutine tests are applied and reported for all transformers that have completed the pro-duction phase. Transformers that passed all tests successfully, can get okey.PAINTThe covers and boilers are cleaned and dried with special chemicals before painting.Rustproof protection, high hold rate and durable first coat primer paint is applied.After primer paint, the boilers are subjected to drying process. 2 or 3 times specialtopcoat paint is applied on the primer paint after drying to meet customer demandpaint thickness. Top coat paint color is used as a RAL 7033.( It can change accordindto customer demand)
TRANSFORMER PRODUCTION FACILITIES Coil Winding Workshop It is the part where the custom made HV and LV winding machines are located. The coils of the transformer are wrapped in this special part. Metalworking Workshop It is the part where the cutting, bending, machining and welding of the metal parts of the transformers are made. Assembly Workshop It is the part where transformer coils, core, cover and boiler assemblies are made.
TRANSFORMERPRODUCTION FACILITIESOven and Oil Pressing WorkshopIt is the part where drying and oiling processes of transformers are made and thespecial vacuum oven and oil pressing units are located.DyehouseIt is the part where the cleaning and painting of the metal parts of thetransformers are made.Test LaboratoryIt is the part where all the final tests of the transformers are made.Stock AreaIt is the part where transformers in ready-to-deliver state are kept.
TRANSFORMER OUR SERVICES (TRANSFORMERS) -Distribution and Power Transformer Production -Transformer Service and Onsite Maintenance • Insulation resistance measurement • DC resistance measurement • Earthing resistance measurement • Measurement of translation rates • Oil puncture voltage measurement • Oil TanӨ (lost angle) measurement(With external service procurement) • Oil chemical tests(With external service procurement) • Air dryer change service • Leakage control and welding retouching service • Accessory seals change service • Contact surfaces cleaning service • Defective accessory repair or replacement service • Oil treatment, change and supplementary service • General Transformer exterior cleaning and painting retouching service • Reporting service of measurements and operations made
TRANSFORMEROUR SERVICES (MV SWITCHGEAR EQUIPMENTS)-MV-LV Cells and Transformer Centers• Bara Connection Control• Circuit Breaker and Separator Function Tests• Secondary Protection System Control• Secondary Protection System Function Tests• Circuit Breaker Contact Resistance Test• Current Transformer Conversion Rate Test• General Transformer exterior cleaning and painting retouching service• Reporting service of measurements and operations made-Engineering Services• Planning and on-site discovery• Projecting and material supply• Project application, Commissioning• Temporary acceptance, Absolute acceptance- After Sales Maintenance, Repair and Support- 24/7 Emergency Technical Service Support
TRANSFORMER TESTRoutine Tests Applied To Transformers: Type Tests Applied To Transformers: • Measurement of winding resistance • Lightning Impact Test • Measuring the voltage conversion ratio and controlling the volt- • Measurement of sound levels age vector phase shift • Measurement of short-circuit impedance and load loss • Temperature increase test • Measurement of idle loss and current • Dielectric routine tests • Short circuit mechanical and thermal strength test - Induced voltage test Special Tests - Applied voltage test • Insulation resistance measurement • Measurement of zero component impedance in three-phase trans- formers • Measurement of harmonics of idle current • Measurement of insulation resistance of windings against earth and measurement of the loss factor of the insulation system ca- pacity
ISO 14001:2004 SERVICE QUALIFICATION CERTIFICATEISO 9001:2008 CAPASITY REPORT OPERATING CERTIFICATE OHSAS 18001-2007 TSE COMPETENCY DOCUMENTTRADEMARK REGISTRATION CERTIFICATE INDUSTRIAL REGISTRATION CERTIFICATE LOCAL GOODS DOCUMENT
SBS TRANSFORMATÖR ELEKTRİK PETROL TURİZM İNŞ. SAN. ve TİC. A.Ş. Office: Büyükesat Mah. Uğur Mumcu Cad. Factory: Ankara Yolu 20. km. Beydeğirmeni Mah.Aknar Apt. 94/7 Çankaya / ANKARA - TURKEY Kümeevler No: 15 KOCASİNAN / KAYSERİ - TURKEYPhone: 0.312 436 65 70 • Fax: 0.312 436 65 71 Phone: 0.352 697 42 40 • Fax: 0.352 697 42 50www.sbstransformator.com