Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore WAGO_750-8202_Datasheet_en

WAGO_750-8202_Datasheet_en

Published by info, 2018-02-27 06:32:55

Description: WAGO_750-8202_Datasheet_en

Keywords: Wago_750-8202

Search

Read the Text Version

750-82023 PLC – PFC200 Controller58 PFC200 CS 2ETH RS 01 02 Marking area Status Serial interface U6 SYS RST A voltage supply -System Fieldbus X3 RS232/485 U5 RUN B -Power jumper connection contacts RJ-45 U4 I/O 24V 0V Data contacts Fieldbus U3 MS Supply connection 24 V RJ-45 U2 NS 0V Supply via Configuration U1 U7 power jumper and programming SD + + contacts interface 24 V ACT X2 LNK ETH ACT X1 LNK 750-8202 —— 0V RUN STOP Power jumper RESET contactsThe PFC200 Controller is a compact PLC for the modular WAGO-I/O-SYSTEM. Programmable to IEC 61131-3Besides network and fieldbus interfaces, the controller supports all digital, • Programmable via WAGO-I/O-PRO V2.3analog and specialty modules found within the 750/753 Series. • Direct connection of WAGO I/O modulesTwo ETHERNET interfaces and integrated switch enable line topology wiring. • 2 x ETHERNET (configurable), RS-232/-485An integrated Web server provides the user with configuration options and • Linux operating system with RT-Preemption patchstatus information from the PFC200. • Configuration via CODESYS, e!COCKPIT or Web-based managementBesides the processing industry and building automation, typical markets forthe PFC200 include the standard machine and plant industries (e.g., interfacepackaging, bottling, textiles, production and metal & wood processing). • Maintenance-freeDescription Item No. Pack. System Data UnitPFC200 CS 2ETH RS 750-8202 1 CPU Cortex A8, 600 MHzPFC200 CS 2ETH RS/T 750-8202/025-000 1 Operating system Real-time Linux (with RT-Preemption patch)Extended temperature range: -20 °C ... +60 °C Main memory (RAM) 256 MbytesPFC200 CS 2ETH RS Telecontrol/T 750-8202/025-001 1 Internal memory (flash) 256 MbytesExtended temperature range: -20 °C ... +60 °C Retain memory 128 KbytesPFC200 CS 2ETH RS Telecontrol ECO/T 750-8202/025-002 1 ETHERNET 2 x RJ-45 (switched)Extended temperature range: -20 °C ... +60 °C Transmission medium Twisted Pair S-UTP 100 Ω, Cat 5;Accessories Item No. Pack. Baud rate Max. line length: 100 m Unit Interface (serial) 10/100 Mbit/s; 10Base-T/100Base-TXWAGO-I/O-PRO V2.3, RS-232 kit 759-333 1 Protocols RS-232/-485 (switchable)SD memory card, 2 GB 758-879/000-001 1 DHCP, DNS, NTP, FTP, FTPS, SNMP, HTTP,Miniature WSB Quick marking system 750-8202/025-001 and -002 HTTPS, SSH, MODBUS (TCP, UDP, RTU) 248-501 5 IEC 60870-5-101/-103/-104, plain see Section 11 Programming IEC 61850-7-4, IEC 61400-25, DNP3 with marking IEC 61131-3 WAGO-I/O-PRO V2.3, e!COCKPIT SD card slot IL, LD, FBD (CFC), ST, FC Type of memory card Push-push mechanism, sealable cover lid SD and SDHC up to 32 GB (AllApprovals guaranteed properties are only valid in connection with the WAGO 758-879/Conformity marking 000-001 memory card.)Korea CertificationMarine applications 1r UL 508 (750-8202)r ANSI/ISA 12.12.014 TÜV 14 ATEX 148929 X DNV GL, GLIECEx TUN 14.0035 X Class I, Div. 2, Grp. ABCD, T4 II 3 G Ex nA IIC T4 Gc (750-8202) Ex nA IIC T4 Gc (750-8202)WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 - D-32385 Minden Tel.: +49(0)571/887-0 E-Mail: [email protected] Hansastr. 27 - D-32423 MindenSubject to design changes 30.05.2017 Fax: +49(0)571/887-169 www.wago.com

3 59 24 V 1Interface RS-232/-485 15 DC ETHERNET DC ELECTRONICS 10 nF ELECTRONICS I/O modules0V 5Interface Bob Smith RS-232/-485 Termination 2 6 47 nF Bob Smith Termination 24 V 2/6 10 nF 47 nF 3 7 0 V 3/7 10 nF 48 10 nF 3.1 4/8750-8202Technical Data General SpecificationsNumber of I/O modules (per node) 64 Dimensions (mm) W x H x L 79 x 65 x 100 with bus extension 250 Height from upper-edge of DIN 35 rail 750-8202/025-002 4 Weight 209.7 g EMC immunity of interference acc. to EN 61000-6-2, marine applicationsInput and output process image (max.) 1000 words EMC emission of interference acc. to EN 61000-6-3, marine applications Internal data bus 1000 words Degree of protection IP20 acc. to DIN 60529 MODBUS 1 x serial interface per TIA/EIA 232 and Type of mounting DIN 35 rail TIA/EIA 485 (switchable), 9-pole D-sub Housing material PCI/O interfaces (serial) female connector Ambient conditions Power supply; 0 °C ... +55 °CDiagnostic LEDs SYS; RUN; Operating temperature -25 °C ... +85 °C FIELDBUS (MS, NS); Storage temperature 95 %User LEDs USER (U1 ... U7); Relative air humidity (no condensation) CAGE CLAMP®Memory configuration CODESYS 2.3 Internal data bus Wire connection 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 via CODESYS library Cross sections 8 ... 9 mm / 0.33 in Program memory Strip lengths Data memory 16 MB Non-volatile memory (retain) 64 MBMemory configuration e!RUNTIME 128 KB Program and data memory Non-volatile memory (retain) 60 MB (dynamically distributed)Power supply 128 KBMax. input current (24 V) 24 V DC (-25 % ... +30 %)Total current for I/O modules (5 V) 550 mAIsolation 1700 mA 500 V system/supply


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook