Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore NitroCatalog2016

NitroCatalog2016

Published by haroldfernandezr, 2016-07-18 17:46:54

Description: NitroCatalog2016

Search

Read the Text Version

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTICAL FIBER Stranded Loose Tube Cable with Steel Tape (GYTS) Stranded Loose Tube Cable with Aluminum Tape (GYTA) FACE PLATE Fig 1 Introduction PE Sheath Introduction Fig 1 PE Sheath In the Nitrotel GYTS cable, single-mode/multimode fibers PSP In the Nitrotel GYTA cable, single-mode/multimode fibers are 78 APL are positioned in the loose tubes, which are made of high Fiber positioned in the loose tubes, which are made of high Red Black Fiber modulus plastic materials, while the loose tubes strand Tube filling compound modulus plastic materials, while the loose tubes strand Tube filling compound together around metallic central strength member into a Loose tube together around metallic central strength member into a Loose tube compact and circular cable core. For certain high fiber count Strength Member compact and circular cable core. For certain high fibre count Strength Member cables, the strength member would be covered with Cable Filling Compound cables, the strength member would be covered with Cable Filling Compound polyethylene (PE). The water-blocking materials are polyethylene (PE). The water-blocking materials are distributed into interstices of the cable core, and the PSP is distributed into interstices of the cable core, and the MODULES longitudinally applied around the cable core before a PE Aluminum Polyethylene Laminate (APL) is longitudinally sheath is extruded over it. applied around the cable core before a PE sheath is extruded over it. Fiber color code Fiber color code 12 34 5 6 9 10 11 12 Yellow Violet Pink Aqua 12 3 4 5 6 7 8 9 10 11 12 Blue Orange Green Brown Gray White Gray White Red Black Yellow Violet Pink Aqua Blue Orange Green Brown Fiber color in each tube starts from No. 1 Blue. 9 Fiber color in each tube starts from No. 1 Blue. Yellow Color codes for loose tube & filler rod Color codes for loose tube & filler rod 1 2 3 4 5 6 7 8 9 10 11 12 12 34 5 6 7 8 10 11 12 Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua Violet Pink Aqua Blue Orange Green Brown Gray White Red Black Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. Order Information and Characteristics of Optical Cables PATCH PANELS Order Information and Characteristics of Optical Cables Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance Fiber Count & Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance kg/km Fiber Count & Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm (increased by 2 fibers) Fillers each Tube mm N N/100 mm each Tube kg/km (increased by 2 fibers) Fillers mm N N/100 mm NT-GYTA-2~30Xn 2~30 5 6 9.2 85 600/1500 300/1000 NT-GYTA-32~36Xn 32~36 6 6 10.2 107 600/1500 300/1000 NT-GYTS-2~30Xn 2~30 5 6 9.8 108 600/1500 300/1000 NT-GYTA-38~60Xn 38~60 5 12 10.4 110 600/1500 300/1000 NT-GYTS-32~36Xn 32~36 6 6 10.4 129 600/1500 300/1000 NT-GYTA-62~72Xn 62~72 6 12 11.4 130 600/1500 300/1000 NT-GYTS-38~60Xn 38~60 5 12 10.6 132 600/1500 300/1000 NT-GYTA-74~96Xn 74~96 8 12 13.6 165 600/1500 300/1000 NT-GYTS-62~72Xn 62~72 6 12 12.1 161 600/1500 300/1000 NT-GYTA-98~120Xn 98~120 10 12 14.8 195 600/2000 300/1000 NT-GYTS-74~96Xn 74~96 8 12 13.6 198 600/1500 300/1000 NT-GYTA-122~144Xn 122~144 12 12 16.4 236 600/2500 300/1000 NT-GYTS-98~120Xn 98~120 10 12 15.4 260 600/1500 300/1000 NT-GYTA-146~216Xn 146~216 18 12 16.4 232 600/2500 300/1000 NT-GYTS-122~144Xn 122~144 12 12 17.2 286 600/1500 300/1000 NT-GYTA-218~288Xn 218~288 24 12 20.0 300 1000/3000 300/1000 OPTICAL FIBER Note: Note: 1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration. 1.Suffix Xn denotes fibre type and see details in Nitrotel cable coding illustration. 2.The color arrangement of fiber and tube is specified in color identification table. 2.The color arrangement of fibre and tube is specified in color identification table. 3.The normal PE sheath thickness is 1.8mm. 3.The normal PE sheath thickness is 1.8mm. Characteristic Temperature requirement Operation -40℃~+70℃ Characteristic Temperature requirement Operation -40℃~+70℃ Installation -10℃~+70℃ Installation -10℃~+70℃ Excellent mechanical and temperature performance guaranteed by the accurate excess fiber length Storage/transportation -40℃~+70℃ Excellent mechanical and temperature performance guaranteed Storage/transportation -40℃~+70℃ Critical protection to fibers, based on the excellent hydrolysis by the accurate excess fiber length resistance and strength performance of tube material and special filling compound filled in the tube Temperature cycling test conform to IEC 794-1-F1 Critical protection to fibers, based on the excellent hydrolysis Temperature cycling test conform to IEC 794-1-F1 Excellent crush resistance and flexibility Excellent ultraviolet prevention with PE sheath Bending Radius Static 10 times of outer diameter resistance and strength performance of tube material and special Bending Radius Static 10 times of outer diameter The following measures are taken to ensure the water blocking Dynamic 20 times of outer diameter filling compound filled in the tube Dynamic 20 times of outer diameter performance of the cable: Excellent ultraviolet prevention with PE sheath - Single steel wire used as the central strength member The following measures are taken to ensure the water - Special water-blocking filling compound in the loose tube - 100% cable core filling Fig 2: High Fiber Count Cable blocking performance of the cable: Fig 2 and 3: High Fiber Count Cable - PSP moisture barrier - Single steel wire used as the central strength Application: Duct/Aeria Fiber member Fiber Fiber CABINETS PSP - Special water-blocking filling compound in the PE Sheath PE Sheath Cable Filling Compound loose tube Tube Filling Compound Cable Filling Compound PE Sheath - 100% cable core filling PE Sheath PE Sheath PE Sheath - APL moisture barrier Cable Filling Compound Tube Filling Compound Application: Duct/Aeria APL APL PE Outer Sheath Loose Tube PSP Tube Filling Compound Loose Tube Strength Member Water-blocking Material Strength Member Strength Member Loose Tube PE Inner Sheathpage 093 Strenght Member page 094 PE Sheath Cable Filling Compound Loose Tube Fiber

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTICAL FIBER Stranded Loose Tube Cable with Steel Tape Stranded Loose Tube Cable with Aluminum Tape and FACE PLATE (Double Sheaths) (GYTY53) Steel Tape (Double Sheaths) (GYTA53) Introduction PE Outer Sheath Introduction PE Outer Sheath MODULES PSP PSP In the Nitrotel GYTY53 cable, single-mode/multimode fibers Filler In the Nitrotel GYTA53 cable, single-mode/multimode fibers are Filler are positioned in the loose tubes, which are made of high positioned in the loose tubes, which are made of high modulus modulus plastic materials, while the loose tubes strand PE Inner Sheath plastic materials, while the loose tubes strand together around Water-blocking Material together around metallic central strength member into a Cable Filling Compound metallic central strength member into a compact and circular PE Inner Sheath compact and circular cable core. For certain high fibre count Water-blocking Material cable core. For certain high fibre count cables, the strength Fiber cables, the strength member would be covered with member would be covered with polyethylene (PE). The water- polyethylene (PE). The water-blocking materials are Strength Member blocking materials are distributed into interstices of the cable Tube Filling Compound distributed into interstices of the cable core . The cable core is Loose Tube core . An APL is longitudinally applied around the cable core, Strength Member covered with a PE inner sheath, and the PSP is longitudinally Fiber then covered with a PE inner sheath; and the PSP is APL applied around the cable core before a PE outer sheath is longitudinally applied over the PE inner sheath before a PE Loose Tube extruded over it. Tube Filling Compound outer sheath is extruded over it. Cable Filling Compound Fiber color code 12 3 4 5 6 7 8 9 10 11 12 Gray White Red Black Yellow Violet Pink Aqua Fiber color code Blue Orange Green Brown 9 Fiber color in each tube starts from No. 1 Blue. Yellow 12 3 4 5 6 7 8 9 10 11 12 Gray White Red Black Yellow Violet Pink Aqua Blue Orange Green Brown Color codes for loose tube & filler rod Fiber color in each tube starts from No. 1 Blue. 12 34 5 6 7 8 10 11 12 Black Violet Pink Aqua Color codes for loose tube & filler rod Blue Orange Green Brown Gray White Red Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. 1 2 3 4 5 6 7 8 9 10 11 12 PATCH PANELS Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua Order Information and Characteristics of Optical Cables Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. Order Information and Characteristics of Optical Cables Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance Fiber Count & Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm kg/km (increased by 2 fibers) Fillers each Tube mm N N/100 mm Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance NT-GYTA53-2~36Xn 2~36 6 6 13.0 199 1000/3000 1000/3000 Fiber Count & Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm 244 1000/3000 1000/3000 kg/km NT-GYTA53-38~72Xn 38~72 6 12 15.0 290 1000/3000 1000/3000 (increased by 2 fibers) Fillers each Tube mm N N/100 mm 333 1000/3000 1000/3000 389 1000/3000 1000/3000 NT-GYTY53-2~36Xn 2~36 6 6 12.6 184 1000/3000 1000/3000 NT-GYTA53-74~96Xn 74~96 8 12 16.8 385 1000/3000 1000/3000 NT-GYTY53-38~72Xn 38~72 6 12 14.0 216 1000/3000 1000/3000 NT-GYTY53-74~96Xn 74~96 8 12 15.7 260 1000/3000 1000/3000 NT-GYTA53-98~120Xn 98~120 10 12 17.8 NT-GYTY53-98~120Xn 98~120 10 12 17.4 301 1000/3000 1000/3000 NT-GYTY53-122~144Xn 122~144 12 12 19.0 354 1000/3000 1000/3000 NT-GYTA53-122~144Xn 122~144 12 12 20 NT-GYTY53-146~216Xn 146~216 18 12 19.0 350 1000/3000 1000/3000 NT-GYTA53-146~216Xn 146~216 18 12 20 Note: OPTICAL FIBER 1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration. 2.The color arrangement of fiber and tube is specified in color identification table. 3.The normal PE sheath thickness is 1.0mm, and PE outer sheath thickness is 2.0mm. Note: Characteristic Operation -40℃~+70℃ 1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration. Installation -10℃~+70℃ 2.The color arrangement of fiber and tube is specified in color identification table. Excellent mechanical and temperature performance guaranteed Temperature requirement 3.The normal PE sheath thickness is 1.0mm, and PE outer sheath thickness is 2.0mm. by the accurate excess fiber length Characteristic Operation -40℃~+70℃ Critical protection to fibers, based on the excellent hydrolysis Storage/transportation -40℃~+70℃ Installation -10℃~+70℃ Excellent mechanical and temperature performance guaranteed Temperature requirement resistance and strength performance of tube material and special by the accurate excess fiber length filling compound filled in the tube Temperature cycling test conform to IEC 794-1-F1 Critical protection to fibers, based on the excellent hydrolysis Storage/transportation -40℃~+70℃ Excellent crush resistance and flexibility Static 12.5 times of outer diameter resistance and strength performance of tube material and special Temperature cycling test conform to IEC 794-1-F1 The following measures are taken to ensure the water blocking Bending Radius Dynamic 25 times of outer diameter filling compound filled in the tube performance of the cable: Excellent crush resistance and flexibility Static 10 times of outer diameter - Single steel wire used as the central strength The following measures are taken to ensure the water blocking Bending Radius member performance of the cable: Dynamic 20 times of outer diameter - Special water-blocking filling compound in Fig 2 and 3: High Fiber Count Cable the loose tube - Single steel wire used as the central strength member Fig 2 and 3: High Fiber Count Cable - 100% cable core filling PE Outer Sheath PSP - Special water-blocking filling compound in - APL moisture barrier PE Outer Sheath Water-blocking Material PE Outer Sheath PE Outer Sheath - PSP moisture barrier PSP PE Inner Sheath PSP APL the loose tube PSP - Water-blocking material Water-blocking Material Loose Tube - 100% cable core filling Water-blocking Material Water-blocking Material PE Sheath - PSP moisture barrier PE Inner Sheath Application: Duct/Aerial/Direct buried PE Inner Sheath Strength Member - Water-blocking material PE Inner Sheath Loose Tube Fiber Fiber Application: Duct/Aeria Loose Tube Strength Member CABINETS PE Sheath Tube Filling Compound Tube Filling Compound Strength Member Fiber Cable Filling Compound Strength Member Tube Filling Compound Cable Filling Compound PE Sheath PE Sheath APL Fiber Loose Tube Tube Filling Compound Cable Filling Compoundpage 095 Cable Filling Compound page 096

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTICAL FIBER FACE PLATE All Dielectric Self-supporting Aerial Cable (ADSS) Figure-8 Cable with Steel Tape (GYTC8S) Introduction PE/At outer Sheath Introduction Stranded Wires 7 x 1.6mm MODULES Water Blocking tape PE Sheath In the Nitrotel ADSS cable, single-mode/multimode fibers are In the Nitrotel GYTC8S cable, single-mode/multimode fibers are positioned in the loose tubes, which are made of high modulus Filler positioned in the loose tubes, which are made of high modulus Fiber plastic materials, while the loose tubes strand together around PE Inner Sheath plastic, while the loose tubes strand together around metallic central Loose Tube non-metallic central strength member(FRP) into a compact and FRP Strenght Memeber strength member into a com. pact and circular cable core, and the Tube Filling Compound circular cable core. The loose tubes are filled with filling water-blocking materials are distributed into interstices of it. After a Cable Filling Compound compound, while water-blocking materials are distributed into Fiber PSP is applied around the cable core, this part of cable accompanied interstices of the cable core. The PE inner sheath is extruded Tube Filling Compound with the stranded wires as the supporting part are completed with a PSP over the cable core with aramid yarns outside. PE sheath to be a figure-8 structure. This kind of cable is specifically PE Sheath Then, the cable is completed with a PE/AT outer sheath. Loose Tube used for self supporting aerial installation extruded over it. Strendth Member Water Blocking Yarn Fiber color code 1 2 3 4 5 6 7 8 9 10 11 12 Fiber color code Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua 12 34 5 6 7 8 9 10 11 12 Yellow Fiber color in each tube starts from No. 1 Blue. Blue Orange Green Brown Gray White Red Black Violet Pink Aqua 9 Color codes for loose tube & filler rod Fiber color in each tube starts from No. 1 Blue. Yellow 1 2 3 4 5 6 7 8 9 10 11 12 Color codes for loose tube & filler rod Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua 12 34 5 6 7 8 10 11 12 Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. Blue Orange Green Brown Gray White Red Black Violet Pink Aqua PATCH PANELS Characteristics of Optical Cables Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. Ref. Outer Ref. Weight Rec. Daily Tensile Break Strength Modulus of Operation, Heat Suitable Span Order Information and Characteristics of Optical Cables (NESC Standard m) Diameter (kg/km) Max. Strength Strength Member CSA Elasticity Storing, Transport Expansion (mm) (kN/mm2) Temperature Coefficient A B CD Working Tension (kN) (kN) (mm2) (oC) (x10-6/K) Cable Cable Type Tensile Strength Crush Resistance Diameter Weight Long/Short Term Long/Short Term PE Sheath AT Sheath (kN) Cable Type Fiber kg/km (increased by 2 fibers) Count mm N N/100 mm 12.5 125 136 1.5 4 10 4.6 7.6 -40~+60 1.8 160 100 140 100 13.0 132 142 2.25 6 15 7.6 8.3 -40~+60 1.5 230 150 200 150 13.3 137 148 3.0 8 20 10.35 9.45 -40~+60 1.3 300 200 290 200 NTGYTC8S-2~30Xn 2~30 9.6 x 21 270 3000/8000 300/1000 NTGYTC8S-32~36Xn 32~36 10.2 x 21.6 285 3000/8000 300/1000 13.6 145 156 3.6 10 24 13.8 10.8 -40~+60 1.2 370 250 350 250 NTGYTC8S-38~60Xn 38~60 320 3000/8000 300/1000 11.6 x 23 13.8 147 159 4.5 12 30 14.3 11.8 -40~+60 1.0 420 280 400 280 14.5 164 177 5.4 15 36 18.4 13.6 -40~+60 0.9 480 320 460 320 NTGYTC8S-62~72Xn 62~72 12 x 23.4 340 3000/8000 300/1000 NTGYTC8S-74~96Xn 74~96 14.2 x 25.6 390 3000/8000 300/1000 14.9 171 185 6.75 18 45 22.0 16.4 -40~+60 0.6 570 380 550 380 NTGYTC8S-98~120Xn 98~120 16.0 x 27.4 430 3000/8000 300/1000 15.1 179 193 7.95 22 53 26.4 18.0 -40~+60 0.3 670 460 650 460 OPTICAL FIBER 15.5 190 204 9.0 26 60 32.2 19.1 -40~+60 0.1 750 530 750 510 NTGYTC8S-122~144Xn 122~144 17.7 x 29.1 480 3000/8000 300/1000 15.6 194 208 10.5 28 70 33.0 19.6 -40~+60 0.1 800 560 800 560 16.3 211 226 12.75 34 85 40.0 20.1 -40~+60 0.1 880 650 880 650 Note: 1. Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration. 16.8 226 242 15.45 41 103 48.0 24.0 -40~+60 -0.4 1000 750 1000 760 2. The color arrangement of fiber and tube is specified in color identification table. 3. The normal PE sheath thickness is 1.8mm. 17.2 236 253 16.2 45 108 51.0 25.1 -40~+60 -0.5 1180 800 1100 830 4. The installation span should not be more than 100m and the installation sag should not be less than 0.5%. Figure-8 cable with other span and standard 0.5% sag is available on request. 17.9 249 266 18.0 50 120 58.8 26.1 -40~+60 -0.8 1180 880 1180 900 5. Dimensions of the figure-8 cable have close relationship with moulds and production process, the above-mentioned dimensions are subject to actual dimensions Note: 1. Only a part of ADSS cables are listed in the table. ADSS cables with other spans can be inquired from Nitrotel directly. Characteristic 2. Specifications in the table are listed under condition that there is no height difference between two suspension points while the installation sag is 1%. 3. Fibre count is 2 to 60. Excellent mechanical and temperature performance 4.Specially designed cable structure is available on request. Critical protection to fibers, based on the excellent hydrolysis resistance and strength performance of tube material and special Characteristic Applicable climate conditions filling compound filled in the tube CABINETS of cable can be divide into four categories The following measures are taken to ensure the water blocking Easy installation performance of the cable: Excellent corrosion resistance, due to AT sheath Climate Type Wind Speed (m/s) Ice (mm) Extra Load (N/m) - Single steel wire used as the central strength member Light weight and small diameter A 25 0 0.7 - Special water-blocking filling compound in the loose tube Large span with the largest span of over 1200m B 35 0 0.7 - 100% cable core filling Accurate excess fibre length and stranding pitch to guarantee the C 10 5 2.5 - PSP moisture barrier good tensile and temperature performance D 10 10 4.4 Application: Duct/Aerial The life expectancy is over 30 yearspage 097 The careful design of aramid yarn quantity and stranding process page 098 can satisfy the demand on various spans. For overhead power lines under 110kV, PE outer sheath is applied. For power lines equal to or over 110kV, Anti-Tracking outer sheath is applied. Application: Aerial

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTICAL FIBER Stranded Loose Tube Cable with Non-metallic Central Single Core Tight Wrapped Indoor FACE PLATE Strength Member (GYFTY) Optical Cable(GJFJV) Introduction PE Outer Sheath Introduction Sheath Filler Aramid Yam Strength Member In the GYFTY cable, single-mode/multimode fibers are The Nitrotel simplex cable (GJFJV) uses single 900µm or 600µm positioned in the loose tubes, which are made of high modulus Cable Filling Compound tight buffered fibre as optical transmission medium, covered with Tight Buffered Optical Fiber plastic materials, while the loose tubes strand together around FRP Strength Member aramid yarn as strength member, then extruded with a PVC Fiber non-metallic central strength member (FRP) into a compact Loose Tube sheath. Other sheath materials, like LSZH and TPU, are available and circular cable core. For certain high fibre count cables, the Fiber on request. strength member would be covered with polyethylene (PE). Tube Filling Compound The water-blocking materials are distributed into the interstices of the cable core. Then the cable is completed with MODULES a PE sheath. Fiber color code 1 2 3 4 5 6 7 8 9 10 11 12 Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua Fiber color in each tube starts from No. 1 Blue. Order Information and Characteristics of Optical Cables Color codes for loose tube & filler rod Tensile Strength Crush Resistance Bending Radius Storage, operating Long/ShortTerm Long/ShortTerm Static/Dynamic Temperature (°C) 1 2 3 4 5 6 7 8 9 10 11 12 Cable Type Cable Size (mm) Weight (kg/km) (N) (N/100 mm) (mm) Blue Orange Green Brown Gray White Red Black Yellow Violet Pink Aqua 100/500 100/500 Tube color in each layer starts from No. 1 Blue. If there are fillers, the color is nature. NT-GYJFJV-1Xn 1.6± 0.2 2.5 60/100 100.500 30/60 -20~+60 PATCH PANELS NT-GYJFJV-1Xn 1.8± 0.2 3.5 60/100 30/60 -20~+60 Cable Type Tube Max. No. of Cable Cable Tensile Strength Crush Resistance NT-GYJFJV-1Xn 2.8± 0.2 6.0 60/100 30/60 -20~+60 Fiber Count & Fibers in Diameter Weight Long/ShortTerm Long/ShortTerm kg/km Note: Xn denotes fiber type. (increased by 2 fibers) Fillers each Tube mm N N/100 mm 92 NT-GYFTY-2~36Xn 2~36 6 6 10.6 102 400/1000 300/1000 Characteristic 103 400/1000 300/1000 NT-GYFTY-38~60Xn 38~60 5 12 11.2 114 600/1500 300/1000 Excellent strippability with tight buffered fiber 125 600/1500 300/1000 Excellent flame retardant properties NT-GYFTY-2~42Xn 2~42 7 6 11.2 160 1000/3000 300/1000 High tensile strength due to aramid strength member 200 1000/3000 300/1000 Excellent corrosion resistant, waterproof, flame retardant and environmental- friendly properties of the outer sheath NT-GYFTY-44~72Xn 44~72 6 12 12.2 235 1000/3000 300/1000 1000/3000 300/1000 NT-GYFTY-2~48Xn 2~48 8 6 12.2 220 1000/3000 300/1000 NT-GYFTY-50~96Xn 50~96 8 12 13.6 Application NT-GYFTY-98~120Xn 98~120 10 12 14.6 Fiber jumper or pigtail Indoor riser level and plenum level cabling NT-GYFTY-122~144Xn 122~144 12 12 16.8 Interconnections between instruments and communication equipments NT-GYFTY-146~192Xn 146~192 8 6 Standards OPTICAL FIBER 12 16.8 Comply with standard YD/T1258.2-2003 and IEC 60794-2-10/11 12 Delivery Length Note: 1.Suffix Xn denotes fiber type and see details in Nitrotel cable coding illustration. Standard Reel Length: 2000m; Other lengths available on request 2.The color arrangement of fiber and tube is specified in color identification table. 3.The normal PE sheath thickness is 2.0mm. Characteristic CABINETS Excellent mechanical and temperature performance guaranteed by the accurate excess fiber length Critical protection to fibers, based on the excellent hydrolysis resistance and strength performance of tube material and special filling compound filled in the tube Excellent ultraviolet prevention with PE sheath Excellent crush resistance and flexibility The following measures are taken to ensure the water blocking performance of the cable: - FRP used as the central strength member - Special water-blocking filling compound in the loose tube - 100% cable core filling Application: Duct/Aerialpage 099 page 100

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTICAL FIBER FACE PLATE Duplex Flat Cable (GJFJBV) Indoor Distribution Cable(GJPFJV) Introduction Inner Sheath Introduction Flame--retardant jacket Tight buffered Fiber Tight buffered optical fiber The duplex flat cable uses two 900µm or 600µm tight In the Nitrotel GJPFJV Indoor Distribution Cable 900μm Aramid Yarn strength member buffered fibers as optical transmission medium, covered with Aramid Yarn Buffered Fibers are surrounded by aramid yarn as strength aramid yarn as strength member while each fibre extruded Outer Sheath members and a flame-retardant jacket. with a PVC inner sheath, then extruded with a flat PVC outer sheath. Other sheath materials, like LSZH and TPU, are MODULES available on request. Order Information and Characteristics of Optical Cables Tensile Strength Crush Resistance Bending Radius Storage, operating Cable Dimensions and Constructions Mechanical and Environmental Characteristics Long/ShortTerm Long/ShortTerm Static/Dynamic Temperature (°C) Cable Type Cable Size (mm) Weight (kg/km) Items Descriptions Items Descriptions (N) (N/100 mm) (mm) Optical Fiber Fiber count 4/8/12/ 24 short -term 600N 100/200 NT-GJFJBV-2Xn (3.0± 0.2) x (5.4± 0.2) 13.8 100/200 100/500 30/60 -20~+60 Tight buffer fibers Material LSZH/PVC long -term 200N NT-GJFJBV-2Xn (3.8± 0.2) x (7.0± 0.2) 20 100/500 40/80 -20~+60 Strength Member Tensile Strength IEC 60794 -2-E1 1000N (>12core) Note: Xn denotes fiber type. Sheath Diameter 0.85 ±0.05mm short -term Cable Diameter Material Aramid yarn long -term 500N (>12core) Cable Weight Material LSZH/PVC short -term 1000N PATCH PANELS Tight buffer Color Code Crush Resistance IEC 60794 -2-E3 300 N Thickness 0.8mm±0.15mm (≤12 Core) long -term Characteristics 1.0mm± 0.10mm (>12core) Excellent strippability with tight buffered fiber Color Yellow/Orange/Aqua Excellent flame retardant properties High tensile strength due to aramid strength member 5.0 ± 0.2 mm (4 Core) Compact arrangement of fiber due to flat structure Excellent corrosion resistant, waterproof, flame retardant and 6.0 ± 0.2 mm (8 Core) environmental- friendly properties of the outer sheath 6.5 ± 0.2 mm (12 Core) 7.5 ± 0.2 mm (18 Core) 8.5 ± 0.2 mm (24 Core) Application Approx 16.2 kg/km Duplex fiber flexible connection jumper or pigtail Approx 27.0 kg/km Indoor riser level and plenum level cabling Instruments communication equipments interconnection Approx 38.0 kg/km Approx 45.0 kg/km Approx 65.0 kg/km Standards blue/orange/green/brown/grey/white/red/black/ OPTICAL FIBER yellow/purple/pink/aqua Comply with standard YD/T1258.2-2003 and IEC 60794-2-10/11 Colors of 2ndgroup of 12 With black tracer tight buffers blue/orange/green/brown/grey/white/red/ Delivery Length yellow/purple/pink/aqua Standard Reel Length: 2000m; Other lengths available on request With white tracer black Packing Wooden Drums Protection Marking CABINETS Cable Marker every Meter by Project name or Project owner Year of manufacture Tape of Cable Number of fiber Cable length Etcpage 101 page 102

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTICAL FIBER OPTIC FIBER PATCH CORDS FTTH Drop Cable(GJXFH-2) Patch Cords FACE PLATE Introduction LSZH jacket Fiber patch cords provide connections from the work area to page 104 MODULES KFRP strength member the wall outlet or from active equipment to the patch panel. This flat drop cable, which consists of 1, 2, or 4 color coded Cords are available as duplex or simplex 62.5/125,50/125, optical fibers, offers an ideal solution for the smaller fiber Fiber(G.657.A2) MM or SM fibers. we offer ST,SC,FC or LC connectors. counts that are needed in the final sections of an optical All patch cords are factory polished and 100% optically tested network. Two parallel FRP strength members protect the for superior performance. optical fibers. The cable is completed with a LSZH jacket. Introduction Order Information and Characteristics of Optical Cables Insertion loss:≤0.3dB Cable Type Cable Size (mm) Weight (kg/km) Tensile Strength Crush Resistance Bending Radius Storage, operating Return loss: Pc≥40dB APC≥60dB Long/ShortTerm Long/ShortTerm Static/Dynamic Temperature (°C) Repeatability: ≤0.3dB Compatibility: ≤0.3dB (N) (N/100 mm) (mm) Insertion times:>1000 Working temperature: -25℃~70℃. NT-GJXFH-1B6a2 (2.0±0.1)×(3.0±0.1) 7.5 40/80 500/1000 15/30 -20~+60 PATCH PANELS NT-GJXFH-2B6a2n (2.0±0.1)×(3.0±0.1) 7.5 40/80 500/1000 15/30 -20~+60 Patch Cords NT-GJXFH-2B6a2n (2.0±0.1)×(3.0±0.1) 7.5 40/80 500/1000 15/30 -20~+60 NTFJ A C B D E F G H Characteristics AB : LC.SC.FC. ST.MTRJ.E2000.MPO/MTP. Simple structure, light weight, high tensile strength and metal free CD: Blank:PC Novel groove design, easily strip and splice, simplified installation and maintenance Low smoke, zero halogen and flame retardant sheath, environment-friendly, good safety. U:UPC A: APC. G657 fiber information E : S: Singlemode OPTICAL FIBER Blank:OM1 Mode field diameter (1310nm):8.6μm±9.5μm. O:OM2 Cladding diameter:125μm±0.7μm. Q:OM3 Coating diameter:245μm±7μm. LO:OM4 Cut off wavelength of cabled fiber ( cc):≤1260μm. F : 01.02.03.04...M Attenuation at 1310nm:≤0.35dB/km. G : SX:Duplex Attenuation at 1550nm:≤0.21dB/km. DX:Duplex Bending loss at 1550nm (100 turns, 30mm radius):≤0.05dB. H : Blank:OD2.0mm Dispersion in the range 1288 to 1339nm:≤3.5ps/(nm km). T: OD3.0mm Dispersion at 1550nm:≤18ps/(nm km). Dispersion slope at zero dispersion wavelength:≤0.092ps/(nm2 km). Pigtail Standards NTFP A C E F G H Comply with standard YD/T1997-2009 A : LC.SC.FC. ST.MTRJ.E2000.MPO/MTP. C : Blank:PC Delivery Length U:UPC Standard Reel Length: 2000m; Other lengths available on request. A: APC. E : : Singlemode Blank:OM1 CABINETS O:OM2 Q:OM3 LO:OM4 F : 01.02.03.04...M G : SX:Duplex DX:Duplexpage 103

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLESTRUCTURE CABLING STRUCTURE CABLINGOPTIC FIBER ADAPTER OPTIC FIBER DISTRIBUTION BOXAdapter SC fast connector FACE PLATEFC/PC Split-body FC/APC One-piece FC/PC Big D FC/PC Small D Characteristics Item Performance Ordering information MODULES Insertion loss Average≤0.2dB, MAX≤0.4dB NTFCPPSC _ Return ross PC:≥40dB,APC≥55dB One-time Assembly Rate ≥97% U: UPC Assembly Repeatability A: APC Average Assembly Time More than 5 times Life-time ≤3 minutes Tensile Strength ≥30years Operation Temperature ≥30N (2x3 Bow-type drop cable) -40~+75℃ST/PC SC/PC SM SC/APC Split--body SC/PC MM Mechanical Splice Characteristics Item Technical Parameters Applicable for Φ0.25 mm &Φ0.90 mm Fiber Optical fiber diameter 125μm ( 652 & 657 ) PATCH PANELS Tight buffer diameter (μm) 250μmSC/PC Duplex SM SC/APC Duplex SM SC/PC Duplex MM LC/APC Duplex SM Fiber mode Single & multi mode Operation time About 10s(no fiber cut) Average Insert loss ≤0.15dB(1310nm & 1550nm) Return loss ≤-40dB Fastening strength of naked fiber >5 N Fastening strength of naked fiber holder >8 N Using temperature -40~+75℃ Repeatability(10 times) △ IL ≤ 0.2dB △ RL ≤ 5dB Shelf optical cable terminal box OPTICAL FIBERLC/PC Duplex SM LC/PC Duplex MM FC-SC/PC FC-SC/PC with ferrule Optical termination box has the following features The splice of optical cable or fiber can be finished individually in the terminal box. It may inlet and outlet not only from optical cable to optical cable but also form optical cable to pigtail. The capacity of terminal box may vary from 8 cores. There is reliable optical cable fixing and ground protection device and sealing device. Order Information PART Number Description Parameter NTTB01-08-SC 8 ports SC simplex adapter shelf optical cable terminal box Insertion loss:≤0.2dB; Repeatability: ≤0.1dB; Insertion times: >1000. NTTB02-08-C8Sports SC duplex adapter shelf optical cable terminal box CABINETS Working temperature: -25℃~70℃; Store temperature:-40℃~85℃. NTTB01-08-S8T ports ST simplex adapter shelf optical cable terminal boxpage 105 page 106

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE STRUCTURE CABLING STRUCTURE CABLING OPTIC FIBER DISTRIBUTION BOX OPTIC FIBER DISTRIBUTION BOX 19\" cabinet optic fiber distribution box Outdoors Fusion Splice Box FACE PLATE Product description: Product description: It can be mounted on 19\" cabinet, optic splicing tray in it, The casing of high strength insulation material has Drawer design, made of armor plate of high quality. excellent mechanical properties. Perfect sealing measures. Order Information This product can be re-opened after sealing, replacement of sealing materials can be reused after. PART Number Description Application NTFPPSC24PSX 24 Port SC Simplex Adaptors Optic Fiber Distribution Box Overhead installation. NTFPPSC12PSX 12 Port SC Duplex Adaptors Optic Fiber Distribution Box Pipe Installation. Direct buried installation. NTFPPST24PSX 24 Port ST simplex Adaptors Optic Fiber Distribution Box Parameter MODULES Dimension(MM):Φ85X 330 19\" cabinet optic fiber distribution box Weight(Kg):1.5 Cable diameter(MM):Ф7-Ф19 Product description: Cable entry ports:two ports in and two ports out PATCH PANELS Max Capacity of Fiber Splice:6 (single) It can be mounted on 19\" cabinet, optic splicing tray in it, Max Capacity of Splice Tray:2 Drawer design, made of armor plate of high quality. Max Capacity:12 (single) Removable Fiber Adapter Panels Structure of cable entry port:heat-shrinkable sealing structure Hinged acrylic front door for a higher dust protection. Sealing structure:silicon gum material. Order Information Outdoors Fusion Splice Box PART Number Description Product description: NTFDB24P ODF 1RU 24 Port SC Duplex Adapter Panels The casing of high strength insulation material has excellent mechanical properties. NTFDB48P ODF 1RU 48 Port SC Duplex Adapter Panels Perfect sealing measures. NTFDB96P ODF 1RU 96 Port SC Duplex Adapter Panels This product can be re-opened after sealing, replacement of sealing materials can be reused after. *Other Fiber Adapter Panels available upon request. Application 19\" cabinet optic fiber distribution box OPTICAL FIBER Overhead installation. Product description: Pipe Installation. It can be mounted on 19\" cabinet, optic splicing tray in it, Parameter Drawer design, made of armor plate of high quality. Dimension (MM):390X 180 X 88. Order Information Weight (Kg):4.2. Cable diameter (MM):Ф5-Ф14. PART Number Description Cable entry ports:Four ports in and Four ports out. NTFPPMPOLC MPO-LC Type Patch Panel Max Capacity of Fiber Splice:12 (single). Max Capacity of Splice Tray:4. Max Capacity:48 (single). CABINETS Structure of cable entry port:heat-shrinkable sealing structure.page 107 Sealing structure:silicon gum material. page 108

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE &page 111 PATCH CABLE STRUCTURE CABLING CABINETS FACE PLATE MODULES PATCH PANELS VE cabinet 113 — 117 OPTICAL FIBER 601S cabinet 118 — 122 123 — 125 CABINETS 603 cabinet 126 — 130 PE cabinet 131 — 132 TE cabinet 133 — 135 SE wall box 136 — 138 139 — 140 EW wall box 141 — 142 SA wall box 143 — 144 SB wall box 145 — 147 SQ wall box 148 — 149 VA wall box 150 — 151 605 data racks 152 — 168 606 open racks Cabinets fitting page 112

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Orion Cabinets CABINET ORION SERVER CABINETS Standard FACE PLATE Comply with ANSI/EIA RS-310-D、 IEC60297-2、DIN41494;PART1; Feature DIN41494;PART7. Packaging: Orion Cabinets could be shipped in disassembled Material packing, saving transportation and storage cost. . SPCC Cold Rolled Steel; 19” rails: 2.0mm; New appearance design :Side door: split into 2 parts, lockable Casters tray:2.0mm; others:1.2mm. with square locks. . Color Front and rear door: pluggable front door and rear doors, with VE: RAL7035. external hinges. . VE: RAL7021. Casters: built-in installation design. . LoadingCapacity Frame: duplex profile frames with patent, could be connected Static loading:1300KG. by 8 pieces of screws. . MODULES Front and rear doors: \"two points\" locking design making doors and frames closed tighter, turning angle up to 180 degrees. . Cable entries on top and bottom: sliding and adjustable cable entries on top and bottom, edges of cable entries are with the design to prevent wires from scratching. . Fan unit: installed from top outside of cabinet, easy to install and maintain. . Mounting rails: installation positions of mounting rails could be adjusted quickly. Dedicated channel alignment reserved in internal of cabinets. . Cabinet structure: patented structure. . Maximum loading capacity: 1300kg. . PATCH PANELS 19” mounting angle with sacle enables 19” zinc coated profile with scale. Multi-function cable manger is OPTICAL FIBER users to precisely locate profile. available in the rear. Safty Warning label. Cable Entrence in the bottom is Cable manager with cover is available CABINETS ajustable. for 800mm width cabinet .page 113 page 114

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET CABINET ORION SERVER CABINETS ORION SERVER CABINETS MainPart OrderingInformation FACE PLATE S/N Specification Qty Material SurfaceFinish Remark PartNumber. Width(mm) Depth(D)(mm) Capacity(U) Height(H)(mm) CKDpackingparts ---- ---- See front&rear door type 600 1200 3 1 Rear door 1 NTSCO■■26U66 800 600 26 2000 4 SPCC t1.2 Powder coated Only used for 800 width cabinet NTSCO■■42U66 42 1200 2 Side panel 4 T2.0 zinc-plated See front&rear door type NTSCO■■26U68 800 26 2000 NTSCO■■42U68 1000 42 2000 3 19” rails 4 SPCC t1.5 Powder coated Only used for 800 width cabinet NTSCO■■42U61 800 42 2000 SPCC t1.2 Powder coated NTSCO■■42U88 1000 42 2000 4 Front beam 2 SPCC t1.2 Powder coated ---- NTSCO■■42U81 42 SPCC t1.0 Powder coated Height:100MM 5 Top cover 1 40pcs for over 33U ---- ---- 4 fans, 115V, 125 CFM/Min 6 Side frame 2 T2.0 zinc-plated 4 ground wires, 1 ground bar SPCC t1.0 Powder coated 7 Cable management slot 2 SPCC t2.0 Powder coated ---- 8 Front door 1 ---- Steel 9 Mounting spacer 4 Steel zinc-plated MODULES Steel zinc-plated 10 Bottom 1 Copper Powder coated Front&Rear Door (type 1) Front&Rear Door (type 4) 11 Caster tray 2 Tempered glass door 12 2” heavy duty castor 4 ---- long-handled lock Sheet steel door with hexagon hardwarekitswithcabinet: 180°Maximum opening angle; hole. Long-handled lock; Material: Sheet steel 4MM 180°Maximum opening angle; A M12 adjustable feet 4 safety glass Surface Finish: Powder coated Material: Sheet steel B M6 screw& nuts 20/40 Colors: RAL7035; RAL7021 Surface Finish: Powder coated Colors: RAL7035; RAL7021 C Quiet fan assembly kit 1 D Grounding kit 1 Additionalfanunitsavailableuponrequest. PATCH PANELS DefinitionofCode NTSCO U Cabinetdepth:(MM):6=600;8=800;1=1000; Front&Rear Door (type 5) Front&Rear Door (type 6) 12=1200 High-density vented door; High density double opened damper Cabinetwidth:(MM):6=600;8=800 Slotted surface(SW7 hexagon) (SW7 hexagon) Air inlet opening>67%; Cabinetcapacity(U): 26, 42. long-handled lock; OPTICAL FIBER Air inlet opening>67%; 180°Maximum opening angle; Definitionofreardoor: long-handled lock; 1: Tempered glass door with striped hole (type 1). 180°Maximum opening angle; Material: Sheet steel 4: Sheet steel door with hexagon hole (type 4). 5: High-density vented door (type 5). Material: Sheet steel Surface Finish: Powder coated 6:High density double opened door with damper (type 6). Surface Finish: Powder coated Color: RAL7035; RAL7021 Definitionoffrontdoor: 1: Tempered glass door with striped hole (type 1). Color: RAL7035; RAL7021 4: Sheet steel door with hexagon hole(type 4). 5: High-density vented door (type 5). 6: High density double opened door with damper (type 6). *Special orders available upon request CABINETSpage 115 page 116

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET Spark Network Cabinet ORION SERVER CABINETS FACE PLATE Standard Assembling Draft MODULES Comply with ANSI/EIA RS-310-D、 CKDPacking IEC60297-2, DIN41494; PATCH PANELS PART1;DIN41494;PART7 Material SPCC Cold Rolled Steel; 19” rails:2.0mm, side panel:1.0mm others: 1.2mm Color RAL7035 RAL9004 LoadingCapacity Static loading: 800KG Feature Exquisite design with precise dimension and craftsmanship. Several styles of front and rear doors options available. Adjustable feet and heavy duty castors are available simultaneously. Cable entry on the top cover and bottom panel with adjustable sizes. Optional installation of plinth to enable cabinets fixation, under-base cable entry/ventilation. Efficient and reliable cabinet connection by baying kit. Removable side panels to ease the maintenance. OPTICAL FIBER CABINETSpage 117 page 118

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLECABINET CABINETSPARK NETWORK CABINETS SPARK NETWORK CABINETSMain Part OrderingInformation FACE PLATES/N Specification Qty Material SurfaceFinish Remark PartNumber. Width Depth(D) Capacity Height(H) CKD ---- ---- See front&rear door type (mm) (mm) (U) (mm) packingparts1 Rear door 1 NTNCS■■15U66 15 800 SPCC t1.0 Powder coated Small round lock NTNCS■■20U66 600 600 20 1022 32 Side panel 2 SPCC t2.0 zinc-plated NTNCS■■24U66 24 1200 SPCC t1.2 6pcs for over 33U NTNCS■■29U66 800 800 29 1422 33 19” rails 4 SPCC t1.2 Powder coated NTNCS■■33U66 33 1600 SPCC t1.2 Powder coated Only used for 800 width cabinet NTNCS■■38U66 900 38 1822 44 Mounting angle 4/6 SPCC t1.0 Powder coated See front&rear door type NTNCS■■42U66 1000 42 2000 Powder coated NTNCS■■47U66 600 47 22225 Top cover 1 ---- Only used for 800 width cabinet : NTNCS■■15U68 800 15 800 SPCC t1.2 ---- 6pcs for over 33U NTNCS■■20U68 900 20 10226 Frame 2 SPCC t1.2 Powder coated NTNCS■■24U68 1000 24 1200 SPCC t1.2 Powder coated ---- NTNCS■■29U68 29 14227 Cable management siot 2 Powder coated NTNCS■■33U68 33 1600 ---- Height:100MM NTNCS■■38U68 38 18228 Front door 1 ---- 40pcs for over 33U NTNCS■■42U68 42 2000 Steel NTNCS■■47U68 47 22229 Mounting spacer 8/12 Steel Zinc-plated ---- NTNCS■■38U69 38 1822 Steel Zinc-plated 4 fans, 115V, 125 CFM/Min NTNCS■■42U69 42 200010 Bottom 1 Steel Zinc-plated 4 ground wires, 1 ground bar NTNCS■■47U69 47 2222 MODULES11 cable entry panel 4 Copper Powder coated NTNCS■■38U61 38 182212 2” heavy duty castor 4 NTNCS■■42U61 42 2000 ---- NTNCS■■47U61 47 2222hardware kits with cabinet: NTNCS■■38U86 38 1822 NTNCS■■42U86 42 2000A M12 adjustable feet 4 NTNCS■■47U86 47 2222 NTNCS■■38U88 38 1822B M6 screw& nuts 20/40 NTNCS■■42U88 42 2000 NTNCS■■47U88 47 2222C Trox tooling 1 NTNCS■■38U89 38 1822D Quiet fan assembly kit 1 NTNCS■■42U89 42 2000 NTNCS■■47U89 47 2222E Grounding kit 1 NTNCS■■38U81 38 1822 NTNCS■■42U81 42 2000Additionalfanunitsavailableuponrequest. NTNCS■■47U81 47 2222 PATCH PANELS Right-angled frame enables Easily connected and removed users to easily place the logo. earth cable available. DefinitionofCode NTNCS U Cabinetdepth:(MM):6=600;8=800;1=1000; OPTICAL FIBER 12=1200 Cabinetwidth:(MM):6=600;8=800 *Special orders available upon request Cabinetcapacity(U): 15, 20, 24, 29, 33, 38, 42, 47. CABINETSpage 119 Definitionofreardoor: 0-Tempered glass door (type 0) 1-Tempered glass door with striped hole (type 1) 2-Tempered glass door with hexagon hole (type 2) 3- Sheet steel door (type 3) 4-Sheet steel door with hexagon hole (type 4) 5-High-density vented door (type 5) Definitionoffrontdoor: 0-Tempered glass door (type 0) 1-Tempered glass door with striped hole (type 1) 2-Tempered glass door with hexagon hole (type 2) 3- Sheet steel door (type 3) 4-Sheet steel door with hexagon hole (type 4) 5-High-density vented door (type 5) page 120

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET CABINET SPARK NETWORK CABINETS SPARK NETWORK CABINETS CKD Packing FACE PLATE Front & rear door(type 0) Front & rear door (type 1) page 122 Tempered glass door. Tempered glass door with striped hole. Small lock; Gray decoration bar; Reversible right or left handed doors; Small lock; Turning angle is over 180 degrees; Reversible right or left handed doors; Material: Turning angle is over 180 degrees; Sheet steel Material: 5MM safety glass Sheet steel Surface Finish: Powder coated 5MM safety glass Color: RAL7035;RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 MODULES Front & rear door (type 2) Front & rear door (type 3) PATCH PANELS Tempered glass door with net hole. Sheet steel door. Gray decoration bar; Small lock; Lock with comfort handle; Reversible right or left handed doors; Reversible right or left handed doors; Turning angle is over 180 degrees; Turning angle is over 180 degrees; Material: Material: Sheet steel Sheet steel Surface Finish: Powder coated 5MM safety glass Color: RAL7035; RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 Front & rear door (type 4) Front & rear door (type 5) OPTICAL FIBER Sheet steel door with hexagon hole. High-density vented door; Small lock; Slotted surface (SW7 hexagon) Air Reversible right or left handed doors; inlet opening>60%; Turning angle is over 180 degrees; Lock with comfort handle; Material: Reversible right or left handed doors; Sheet steel Turning angle is over 180 degrees; Surface Finish: Powder coated Material: Sheet steel Color: RAL7035; RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 CABINETSpage 121

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Server Cabinets CABINET SERVER CABINETS FACE PLATE Standard Feature MODULES Comply with ANSI/EIA RS-310-D、 IEC60297-2、DIN41494; PART1; Reticular high-density vented front door (patent) & rear door DIN41494; PART7 . for protection, ventilation and reliable operation. Exquisite image (patent) with precise dimension and Material craftsmanship. Lockable cable entry on top cover and bottom panel with SPCC Cold Rolled Steel; adjustable sizes. 19” rails:2.0mm, frame: 1.5mm, Optional plinth enables cabinets to stay in a fixed position others: 1.2mm. while meeting requirements of under-base wiring/ventilation and rat prevention. Color Strong cabinet connection by baying kit (patent). Lock with handle. RAL7035. RAL9004. LoadingCapacity Static loading:1000KG. PATCH PANELS MainPart S/N Specification Qty Material SurfaceFinish Remark 1 Side panel 2 SPCC t1.2 Powder coated 2 Rear door 1 SPCC t1.2 Powder coated Double high-density vented OPTICAL FIBER 3 Frame 1 SPCC t1.5 Powder coated 4 Top cover 1 SPCC t1.2 Powder coated ---- 5 19” rails 4 SPCC t2.0 Powder coated 6 Front door 1 SPCC t1.2 Powder coated High-density vented Powder coated ---- 7 Mounting plate 2 SPCC t1.5 ---- ---- ---- 8 2” heavy duty castor 4 ---- v A M12 adjustable feet 4 ---- B M6 screw& nuts 20 Steel Color zinc 40pcs for over 33U Steel Color zinc ---- C Trox tooling 1 Steel Powder coated C Quiet fan assembly kit 1 4 fans, 115V, 125 CFM/Min D Grounding kit 1 Copper ---- 4 ground wires, 1 ground bar The 600mm width cabinet can be changed to the 800mm width one, only need to put the connecting panel and 2 cable management slots. Support 19” EIA equipment. Additional fan units available upon request. CABINETSpage 123 page 124

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET Network Cabinets SERVER CABINETS Standard OrderingInformation FACE PLATE Comply with ANSI/EIA RS-310-D, ModelNo. Capacity(U) Width(mm) Depth(D)(mm) Height(H)(mm) PackingdimensionW*D*H IEC60297-2, DIN41494; PART1; 600 1600 670*670*1700 DIN41494; PART7 . NTSC33U66 33 1800 670*670*1900 800 2000 670*670*2100 Material NTSC38U66 38 2200 670*670*2300 900 1600 670*870*1700 SPCC Cold Rolled Steel; NTSC42U66 42 1800 670*870*1900 19” rails:2.0mm, others: 1.2mm. 1000 2000 670*870*2100 NTSC47U66 47 600 2200 670*870*2300 Color 800 1600 670*970*1700 NTSC33U68 33 900 1800 670*970*1900 RAL7035. 1000 2000 670*970*2100 RAL9004. NTSC38U68 38 2200 670*970*2300 2000 670*1070*2100 LoadingCapacity NTSC42U68 42 600 2200 670*1070*2300 NTSC47U68 47 2000 870*670*2100 Static loading:800KG. 2000 870*870*2100 NTSC33U69 33 2000 870*970*2100 page 126 MODULES 2000 870*1070*2100 NTSC38U69 38 NTSC42U69 42 NTSC47U69 47 NTSC42U61 42 NTSC47U61 47 NTSC42U86 42 NTSC42U88 42 800 NTSC42U89 42 NTSC42U81 42 Note: Cabinet should not in flat packing. DefaultFrontandRearDoors PATCH PANELS Front Door (type 5) Rear Door (type 6) OPTICAL FIBER High-density vented door; Slotted surface(SW7 hexagon) High density double opened damper Air inlet opening>67%; long-handled lock; (SW7 hexagon) Air inlet opening>67%; 180°Maximum opening angle; long-handled lock; Material: Sheet steel 180°Maximum opening angle; Surface Finish: Powder coated Color: RAL7035; RAL7021 Material: Sheet steel Surface Finish: Powder coated Color: RAL7035; RAL7021 CABINETSpage 125

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET CABINET NETWORK CABINETS NETWORK CABINETS Feature OrderingInformation FACE PLATE Flat packing and patent frame, packing time is less than PartNumber. Width(mm) Depth(D)(mm) Capacity(U) Height(H)(mm) CKDpackingparts 20 minutes, Exquisite design with precise dimension and craftsmanship. NTNC15U66 15 800 Several styles of front and rear door options available. Adjustable feet and heavy duty castors are available NTNC20U66 20 1000 simultaneously. Cable entry on the top cover and bottom panel with NTNC24U66 24 1200 adjustable sizes . Optional installation of plinth to enable cabinets fixation, NTNC29U66 29 1400 under-base cable entry/ventilation. NTNC33U66 600 Efficient and reliable cabinet connection by baying kit. Removable side panels to ease the maintenance. 33 1600 NTNC38U66 38 1800 NTNC42U66 42 2000 NTNC47U66 47 2200 3 NTNC15U68 15 800 NTNC20U68 20 1000 MODULES NTNC24U68 24 1200 NTNC29U68 600 29 1400 NTNC33U68 800 33 1600 NTNC38U68 38 1800 NTNC42U68 42 2000 NTNC47U68 47 2200 NTNC38U69 900 38 1800 3 PATCH PANELS NTNC42U69 1000 42 2000 4 NTNC47U69 600 47 2200 NTNC38U61 800 38 1800 NTNC42U61 42 2000 NTNC47U61 800 47 2200 NTNC38U86 38 1800 NTNC42U86 42 2000 NTNC47U86 47 2200 NTNC38U88 38 1800 NTNC42U88 42 2000 NTNC47U88 47 2200 NTNC38U89 38 1800 MainPart NTNC42U89 900 42 2000 S/N Specification Qty Material SurfaceFinish Remark NTNC47U89 47 2200 1 Front door 1 ---- Powder coated See next page NTNC38U81 1000 38 1800 NTNC42U81 42 2000 2 Frame 2 SPCC t1.2 Powder coated ---- NTNC47U81 47 2200 OPTICAL FIBER 3 Side frame 2 SPCC t1.2 Powder coated ---- Side panel Packing dimensions: Carton width=cabinet width+40mm, Carton depth=cabinet depth+40mm, Carton height=cabinet hight+90mm 4 2 SPCC t1.2 Powder coated ≥ 1000 width cabinets need 4 panels 5 Rear door 1 ---- Powder coated See next page 6 Top cover 1 SPCC t1.2 Powder coated ---- Front door (type 0) Rear door (type 3) Tempered glass door. Sheet steel door. 7 19” rails 4 SPCC t2.0 Powder coated ---- Small lock; Small lock; Reversible right or left handed doors; Reversible right or left handed doors; 8 Bottom 1 SPCC t1.2 Powder coated ---- Turning angle is over 180 degrees; Turning angle is over 180 degrees; Material: Material: 9 2” heavy duty castor 4 ---- ---- ---- Sheet steel Sheet steel 5MM safety glass Surface Finish: Powder coated A M12 adjustable feet 4 ---- v ---- Surface Finish: Powder coated Color: RAL7035; RAL9004 Color: RAL7035;RAL9004 B M6 screw& nuts 20 Steel Color zinc 40pcs for over 33U C Trox tooling 1 Steel Color zinc ---- D Quiet fan assembly kit 1 Steel Powder coated 4 fans, 115V, 125 CFM/Min F Grounding kit 1 Copper ---- 4 ground wires, 1 ground bar The 600mm width cabinet can be changed to the 800mm width one, only need to put the connecting panel and 2 cable management slots. CABINETS Support 19” EIA equipment. Additional fan units available upon request. 127 page 128page

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINET CABINET DOORS FOR NETWORK CABINETS NETWORK CABINETS Front & rear door (type 0) Front & rear door (type 1) Additionalaccessoriesforthecabinets FACE PLATE Tempered glass door. Tempered glass door with striped hole. Small lock; Gray decoration bar; Reversible right or left handed doors; Small lock; Turning angle is over 180 degrees; Reversible right or left handed doors; Material: Turning angle is over 180 degrees; Sheet steel Material: 5MM safety glass Sheet steel Surface Finish: Powder coated 5MM safety glass Color: RAL7035;RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 Shelf Plinth Fan units MODULES Front & rear door (type 2) Front & rear door (type 3) M6 Screws & nets PDU Tempered glass door with net hole. Sheet steel door. Gray decoration bar; Small lock; AssemblingDraft PATCH PANELS Lock with comfort handle; Reversible right or left handed doors; Attention Reversible right or left handed doors; Turning angle is over 180 degrees; Turning angle is over 180 degrees; Material: Please remove front/back door Material: Sheet steel and side plane from the frame Sheet steel Surface Finish: Powder coated prior to unpacking 5MM safety glass Color: RAL7035; RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 3. Assemble top cover, bottom panel, adjustable feet and castor feet (screw M5x10). Front & rear door (type 4) Front & rear door (type 5) 1A.Assemble mounting rails (width 2A.Assemble frames (width OPTICAL FIBER Sheet steel door with hexagon hole. High-density vented door; 600mm).(Screw M6x12 & nuts). 600mm).(Screw M6x12 & nuts). Small lock; Slotted surface (SW7 hexagon) Air Reversible right or left handed doors; inlet opening>60%; Turning angle is over 180 degrees; Lock with comfort handle; Material: Reversible right or left handed doors; Sheet steel Turning angle is over 180 degrees; Surface Finish: Powder coated Material: Sheet steel Color: RAL7035; RAL9004 Surface Finish: Powder coated Color: RAL7035; RAL9004 1B.Assemble mounting rails and spacers (width 800mm). (Screw M6x12 & nuts). 2B.Assemble frames (width 800mm) 4.Assemble front/rear CABINETS (screw M5x10). door and side panels.page 129 page 130

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Star Wallmount Cabinet WALLMOUNT CABINET START DOUBLE SECTION Standard Feature FACE PLATE Comply with ANSI/EIA RS-310-D, IEC60297-2, DIN41494, PART1, Double -section wallmount cabinet. MODULES DIN41494, PART7 Tempered glass front door with 180° turning radius rotatable key lock. Material Removable side and rear panels for quick installation of equipment. SPCC Cold Rolled Steel; Adjustable front and rear mounting posts conform to Thickness: 19” rails: 1.2mm, different equipment depth requirements. Dual side panel 1.0mm, others: 1.2mm mounting post with #12-24 threaded holes and square holes for cage nuts. Color Ventilated door design for added air flow and cooling. Cable entry brush panel on the top cover and knock-outs on RAL7035 the bottom plate. RAL9004 Provided with 1 fans with UL cord installed. Additional fan may be provided upon request. Loading Capacity Easy to wall mount back plate. Available in heights from 6u to 23u. Static loading: Up to 95 KG Fully assembled for quick installation and packaged in a honeycomb carton. Optional space saving flatpage 141 packaging available upon request. DefinitionofCode NTDWC U650 Cabinetcapacity(U): 6, 9, 12, 16, 20, 23 Definitionof frontdoor: PATCH PANELS 0-Tempered glass door (type 0) 1-Tempered glass door with striped hole (type 1) 2-Tempered glass door with hexagon hole (type 2) 3- Sheet steel door (type 3) 4-Sheet steel door with hexagon hole (type 4) 5-High-density vented door (type 5) Main Part Specification Qty Material Surface Finish Remark S/N Front door 1 5MM toughed glass Powder coated ---- door/ SPCCt1.2 1 Side panel Powder coated ---- Front frame 2 SPCC t1.0 Powder coated ---- 2 Back frame Powder coated ---- 3 1 SPCC t1.2 Powder coated ---- 4 19 '' rails ---- 5 M6 screw& nuts 1 SPCC t1.2 Color zinc ---- A Trox tooling Black B 4 SPCC t1.2 10 Steel 1 Steel OPTICAL FIBER Specification RU Width (mm) Depth(D)(mm) Height(H)(mm) Static Loading Capacity (kg) Model N o. 6 600 650 370 70 NTDWC■6U650 NTDWC■9U650 9 600 650 500 70 NTDWC■12U650 NTDWC■16U650 12 600 650 635 75 NTDWC■20U650 NTDWC■23U650 16 600 650 770 80 20 600 650 900 90 23 600 650 1080 95 CABINETS page 142

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Star Wallmount Cabinet WALLMOUNT CABINET START SINGLE SECTION Standard Feature FACE PLATE Comply with ANSI/EIA RS-310-D, IEC60297-2, DIN41494, PART1; Double -section wallmount cabinet. MODULES DIN41494, PART7 Tempered glass front door with 180° turning radius rotatable key lock. Material Removable side and rear panels for quick installation of equipment. SPCC Cold Rolled Steel; Adjustable front and rear mounting posts conform to Thickness: 19” rails: 1.2mm, different equipment depth requirements. Dual others: 1.0mm mounting post with #12-24 threaded holes and square holes for cage nuts. Color Ventilated door design for added air flow and cooling. Cable entry brush panel on the top cover and knock-outs on RAL7035 the bottom plate. RAL9004 Provided with 1 fans with UL cord installed. Additional fan may be provided upon request. Loading Capacity Easy to wall mount back plate. Available in heights from 6u to 23u. Static loading: Up to 115 KG Fully assembled for quick installation and packaged in a honeycomb carton. Optional space saving flatpage 143 packaging available upon request. DefinitionofCode NTFWC U600 Cabinetcapacity(U): 6, 9, 12, 16, 20, 23 Definitionoffrontdoor: 0-Tempered glass door (type 0) Main Part Specification Qty Material Surface Finish Remark PATCH PANELS Frame 1 SPCC t1.0 Powder coated ---- S/N 2 SPCC t1.0 Powder coated ---- 1 Side panel 1 5MM toughed glass 2 ---- ---- 3 Front door 4 SPCC t1.2 ---- 4 10 Steel Powder coated ---- A 19 '' rails 1 Steel Color zinc ---- B M6 screw& nuts Black Trox tooling Specification RU Width (mm) Depth(D)(mm) Height(H)(mm) Static Loading Capacity (kg) OPTICAL FIBER Model N o. 6 600 600 370 90 NTFWC06U600 NTFWC09U600 9 600 600 500 90 NTFWC012U600 NTFWC016U600 12 600 600 635 95 NTFWC020U600 NTFWC023U600 16 600 600 770 100 20 600 600 900 110 23 600 600 1080 115 CABINETS page 144

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Gemini 4-post Rack DATA RACK GEMINI 4-POST RACK FACE PLATE Standard Additional accessories Comply with ANSI/EIA RS-310-D,IEC60297-2, DIN41494, PART1, DIN41494, PART7 L bracket (upon request) Material MODULES SPCC Cold Rolled Steel; Trim plate (upon request) Column:1.5mm, others: 2.0mm Fix Shelf (upon request) PATCH PANELS Color Main Part Qty Material Surface Finish Remark OPTICAL FIBER RAL7035 4 SPCC t1.5 Powder coated ---- RAL9004 S/N Specification 4 SPCC t1.5 Powder coated ---- 1 Column 2 SPCC t2.0 Powder coated ---- Loading Capacity 2 Plinth 4 ---- 3 Support Cross beam 20 Steel Color zinc Static loading: 250KG 4 2” heavy duty castor 1 Steel Black 40pcs for over 33U A M6 screw& nuts ---- Features B Trox tooling Modular design, easily assemble and disassemble Specification for low-cost delivery. Additional accessories available upon request. Model N o. RU Width (mm) Depth(D)(mm) Height(H)(mm) Volume (CBM) 1420*260*140page 147 NTFRG4P29USTBK 29 600 600 1422 1600*260*140 1820*260*140 NTFRG4P33USTBK 33 600 600 1600 2000*260*140 2220*260*140 NTFRG4P38USTBK 38 600 600 1822 NTFRG4P42USTBK 42 600 600 2000 NTFRG4P47USTBK 47 600 600 2222 The packing information is for the flat pack and we suggest to use this flat pack to get significant cost saving. CABINETS page 148

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE Gemini 2-post Rack DATA RACK FACE PLATE Standard GEMINI 2-POST RACK Comply with ANSI/EIA RS-310-D, IEC60297-2, Feature DIN41494, PART1, DIN41494, PART7 Modular design, easily assemble and disassemble for delivery, Material low-cost. Various optional accessories according to requirements(cable SPCC Cold Rolled Steel; management slot, removable working panel, etc.). Column: 1.5mm, others: 2.0mm Additional accessories upon request Color Double Sided Shelf Solid shelf MODULES RAL7035 RAL9004 Horizontal cable management PATCH PANELS Loading Capacity Main Part Qty Material Surface Finish Remark OPTICAL FIBER 2 SPCC t1.5 Powder coated ---- Static loading: 150KG S/N Specification 2 SPCC t2.0 Powder coated ---- 1 Column 2 SPCC t2.0 Powder coated ----page 149 2 Plinth 4 ---- 3 Support Cross beam 20 Steel Color zinc 4 2” heavy duty castor 1 Steel Black 40pcs for over 33U A M6 screw& nuts ---- B Trox tooling Volume (CBM) Specification RU Width (mm) Depth(D)(mm) Height(H)(mm) 1420*260*140 1600*260*140 Model N o. 29 600 600 1422 1820*260*140 NTFRG2P29USTBK 2000*260*140 NTFRG2P33USTBK 33 600 600 1600 2220*260*140 NTFRG2P38USTBK NTFRG2P42USTBK 38 600 600 1822 NTFRG2P47USTBK 42 600 600 2000 47 600 600 2222 CABINETS page 150

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING PDU Output unit type PDU FACE PLATE PDU Input connector type Style AS/NZS 3112 Style DIN49440 Name Master switch Name Master overload Parameter 16A 250VAC Protector & power Parameter 10(15A) 250VAC indicator MODULES Style IEC320 C13(C19) Style BS1363(90°) Parameter Mini circuit Code LY-A Parameter 10(16A) 250VAC Parameter 13A 250VAC breaker(1~60A) Name protective device Input connector type Plug style Bs1363 Plug style AS/NZS 3112 Parameter 13A 250VAC Parameter 10/15A 250VAC PATCH PANELS Style BS1363(45°) Style NEMA 5-15R Code LY-B Parameter 13A 250VAC Parameter 15A 150VAC Name protective device Plug style IEC60329 Plug style IEC320 C14(C20) Plug style DIN49441 Plug style NEMA 5-15P Surge protective device Surge protective device:LY-B Parameter 10(16A) 250VAC Parameter 16A 250VAC Parameter 15A 125VAC Parameter 16/32A 250VAC TUL-LY-A/B Parameter Rated voltage 250VAC 50/60Hz Rated load current IR 16A OPTICAL FIBER Max. power PMAX 4000W Max.Continuous operating voltage UC 320VAC Red LED light, when working, means the CABINETS Measured limiting voltage Ur <1000V Power had Unicom and filtering output. Nominal discharge current(8/20μs)In 10KA Voltage protection level Up <1000V Green LED light, when disabled, means Response time TA <25nS the failure ofThe lighting protection circuit. Protection mode L-N L-PE N-PE Earth indicator Yellow LED Yellow LED light, when working, Lightning protection Green LED means the absence of earth wire of the Power indicator Red LED power supply system, which shall be case Alternative filtration Highly efficient to contact electrician for his professional Insulation resistance RIS >100MΩ and grounding. Fire resistance Up to UL 94V-0 Environment temperature -40~+70℃ Relative humidity <=95%page 153 page 154

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING TC DIGITAL TEMPERATURE UNIT TC DIGITAL TEMPERATURE UNIT TC Digital Temperature Unit Control outprt Lndicator light description FACE PLATE 19”installation Compressor:When the storage temp.ls higher than set Indicator light Status Function Simple structure, easy installation; temp.Upper limit,compressor starts,lower than set temp. Cool Always on Compressor cutput Easy cabling & operation; Lower limit,compressor stops,When sensor errir, Cool Flashes Compressor cutput delay Disturbing resistance、reliable running; compressor works proportionably as on -15 minutes off-30 Set Always on Parameter modification status 2-way output (IEC320 C13 and NEMA 5-15R). minutes.After electrified or compressor stops.Compressor restart-up is allowed after running out of compressor Technical parameters protection time. Wire diagram Power supply:220VAC+10%/-15%,50/60Hz. Alarm:While temp.exceeding valus is not 0.LED blinkingly 10A/277VAC 10A/277VAC Temperature measuring range:-50℃ ~99℃. displays current temperature when storage temperature is Resoluton:1℃. higher than set temperature upper limip +exceeding temp MODULES Refrigeration output contact capacity:10A/277VAC. value or lower than set lower limit-exceeding temp.walue. Senssor error delay time:1min. Key operation When rumming out of the exceeding temp.limit alarm delay Storage temp. Power supply Safe level:1P65. after electrified.exceeding temp.limit alarm starts with Sensor 220VAC Operation humidity:20~85%(no condensate). Check parameter set value: buzzer sound,and alarm cancel when temperature return Power consumption:≤3W. Press ▲ and then loosen to display the set upper limit; to normal temperature LED blinkingly Display E1 with Closed point Temperature controling range:-40℃ ~50℃. Press and then loosen ▼ to display the. buzzer sound when memorizer error;display E2 with Co-point Accuracy:-50℃ ~70℃,±1℃,±1℃at others can buzzer sound when sensor error,Display HH when temp. Defrost drive single phase compressor≦1/2HP. Modify parameter set value Higher than 99℃ and lower than 120℃。Press any key Closed point Sensor:NTC. to cancel alarm sound,but alarm status remains. Co-point OpERATION TEMPERATURE:-30℃ ~75℃. Press set for more than 3s to cnter into parameter modifying Compressor status the last,display the last adjusted menu after electrified Front panel with parameter modifying indicator light on. Key-press function Press ▲ or ▼ to go forward or backward the menu item; press set to display the current. Item Function Fetting range Unit Default PATCH PANELS F1 Upper limit F2~+50 ℃ -10 Parameter set value F2 Lower limit -F40~F1 ℃ -20 F3 Temperature calibration -5~5 ℃ 0 Press set and■or■simultaneously can adjust the current F4 Compressor protection time 0~9 Min 3 parameter set value;press set and■simultaneously more F5 Exceeding temperatuer value ℃ 15 than 1s will increase current parameter set value quickly; F6 Exceeding temperature alarm delay time 0~50,set value as 0 to cancel alam Min 20 press set and■simultaneously more than 1s will decrease 0~99 current parameter set value puickly; Press rst or no key operation in 30s will save the modified Safety regulations Error code parameter and retutn to normaltemperature display status. Danger:Strictly distinguish the sensor down-lead,power Restore the parameter setting wire and output relay interface from one another,prohibit Code Reason Status wrong connections or overloading the relay. E1 Memorizer error When electrify the controller,first check the parameter All connections should be modified under electricity cut-off. Alarm,machine does not work setting,if parameter setting is wrong,LED display E1 with E2 Sensor error OPTICAL FIBER buzzer sound,at this time press Set will restore default Warning:Prohibit to use the machine in water or under the Alarm.Comressor starts parameter setting. environment of ower damp,high temperature,string /stop proportionably Advise to reset the parameter. electromagnetism interference ir string corrosion. HH Exceeding temp, display limit Key-press function Key-press Normal mode Parmeter modification mode Caution:The power supply should conform to one labeled SET Check compressor protection time Display current menu set value on the machine,and ensure the stability of the power voltage. Enter into parameter modification Sensor down-lead and power should be kept for a proper SET…3seconds Check temperature exceeding value Quit from parameter modification distance to avoid possible interferences. Rst Temperature upper limits checking Menu items go backwards ▲ Temperature lower limits checking Menu items go forwards ▼ Parameter values increase by degrees SET+▲ Parameter values decrease by degrees SET+▼ CABINETSpage 155 page 156

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING COOLING COLLING 2/4 Fan Units 1U Fan Units FACE PLATE Parameter 19” standard installation, MODULES 1U Switch control fans work. Fan size:120X120X38, cable length: 1.9M Input frequency: 100~231V/50Hz Parameter Period: -10℃~+50℃ Material: SPCC cold rolled steel Fan size: 120X120X38, cable length: 1.9M Color: RAL7035 Input frequency: 100~231V/50Hz Period: -10℃~+50℃ RAL9004 Material: SPCC cold rolled steel Color: RAL7035 Main part: RAL9004 Model No. Description Input connector type Main part: NTFAN2UK 2 fans UK type(BS1363) NTFAN2GE 2 fans Model No. Description Input connector type NTFAN2US 2 fans German type(DIN49441) UK type(BS1363) NTFAN4UK 4 fans US type(NEMA 5-15P) NTFAN1U2UK 2 fans NTFAN4GE 4 fans German type(DIN49441) NTFAN4US 4 fans UK type(BS1363) NTFAN1U2GE 2 fans US type(NEMA 5-15P) German type(DIN49441) US type(NEMA 5-15P) NTFAN1U2US 2 fans UK type(BS1363) German type(DIN49441) NTFAN1U3UK 3 fans US type(NEMA 5-15P) NTFAN1U3GE 3 fans UK type(BS1363) German type(DIN49441) NTFAN1U3US 3 fans US type(NEMA 5-15P) NTFAN1U4UK 4 fans NTFAN1U4GE 4 fans PATCH PANELS NTFAN1U4US 4 fans 2/4 Fan Units With Thermostat Parameter 3U Fan Units large setting range: 0℃~+60℃ 19” standard installation, 3U small size High switching performance Parameter OPTICAL FIBER Fan size:120X120X38, Cable length:1.9m Input frequency:100~231V/50Hz Fan size: 120X120X38, cable length: 1.9M Material:SPCC cold rolled steel Input frequency: 100~231V/50Hz Color:RAL7035 Period: -10℃~+50℃ Material: SPCC cold rolled steel RAL9004 Color: RAL7035 Main part: RAL9004 Model No. Description Input connector type Main part: NTFANT2UK 2 fans UK type(BS1363) NTFANT2GE 2 fans Model No. Description Input connector type NTFANT2US 2 fans German type(DIN49441) UK type(BS1363) NTFANT4UK 4 fans US type(NEMA 5-15P) NTFAN3U2UK 2 fans NTFANT4GE 4 fans German type(DIN49441) NTFANT4US 4 fans UK type(BS1363) NTFAN3U2GE 2 fans US type(NEMA 5-15P) German type(DIN49441) US type(NEMA 5-15P) NTFAN3U2US 2 fans UK type(BS1363) German type(DIN49441) NTFAN3U3UK 3 fans US type(NEMA 5-15P) NTFAN3U3GE 3 fans NTFAN3U3US 3 fans CABINETSpage 157 page 158

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING SHELVES SHELVES Cooling Fan Fixed Shelf FACE PLATE For network cabinet, adjust inner temperature Only for Nitrotel cabinet, install from side. Performance reference. Parameter Parameter Static load capacity: 90 Kg [198Lb] Size:120X120X38 Material: SPCC 1.2 cold rolled steel Atmosphere runoff: 50CFM, Noise: 24.9 dB Color: RAL7035 periode: -10℃~+50℃ RAL9004 Main part: Main part: Model No. Shelf size MM Use MODULES Model No. Description Input(v) Axletree Type NTFS350 Width Depth 600MM NTFS550 800MM NTFANU AC fans 115 Oiliness Axletree NTFS620 485 350 900MM NTFS720 1000MM cabinet 485 550 485 620 485 720 Solid Shelves Used for 19 inch network cabinet and rack. Vented Shelves PATCH PANELS Parameter Used for 19 inch network cabinet and rack. Material: SPCC cold rolled steel. Parameter Color: RAL7035 material: SPCC cold rolled steel. RAL9004 Color: RAL7035 Main part: Description Capacity RAL9004 2U-15” DP 22Kg.[48Lb] Model No. 2U-18” DP 22Kg.[48Lb] NTSS2UX15 NTSS2UX18 Main part: Double Sided Shelf (2U) Model No. Description Capacity OPTICAL FIBER NTVS1UX105 1U-10.5” DP 14Kg.[30Lb] Used for 19” open rack, 2U height. NTVS1UX12 16Kg.[35Lb] NTVS1UX15 1U-12” DP 23Kg.[50Lb] Parameter NTVS1UX18 1U-15” DP 26Kg.[56Lb] NTVS2UX105 1U-18” DP 16Kg.[35Lb] material: SPCC cold rolled steel. NTVS2UX12 2U-10.5” DP 18Kg.[39Lb] Color: RAL7035 NTVS2UX15 2U-12” DP 24Kg.[52Lb] NTVS2UX18 2U-15” DP 25Kg.[54Lb] RAL9004 2U-18” DP Main part: Model No. Description Capacity NTSSD2U25 2U-25” DP 50Kg.[110Lb] CABINETSpage 159 page 160

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING SHELVES PANEL/BRACKETS Keyboard With Mouse Panel (1U) L Brackets FACE PLATE Used for 19 inch network cabinet. Only for SHIP 19” cabinet and wall box, install from side. Keyboard allowed maximum size 4200X200MM. Keyboard and mouse are individually placed for Parameter convenient operation. Static load capacity: 15 Kg [33Lb] Parameter Material: SPCC cold rolled steel. Color: RAL7035 material: SPCC cold rolled steel. Color: RAL7035 RAL9004 RAL9004 Ordering information Main part: MODULES Model No. Description Use Model No. Description Length Use NTLB45 45 type 300 450MM wall box NTMKS1UX18 Keyboard and mouse shelf 600~800MM cabinet NTLB66 66 type 450 600MM wall box NTLB60 60 type 320 600MM cabinet Keyboard and Mouse Drawer (2U) NTLB80 80 type 520 800MM cabinet NTLB90 90 type 620 900MM cabinet NTLB10 10 type 720 1000MM cabinet Used for 19 inch network cabinet. Blanking Panel PATCH PANELS Keyboard allowed maximum size 450X200MM. Keyboard and mouse are individually placed for convenient operation. Compatible with 19 inch network cabinet, cover the blank position. Parameter Parameter Material: SPCC cold rolled steel. Color: BLACK Material: SPCC cold rolled steel. Color: RAL7035 Main part: Use 800~1000MM cabinet RAL9004 Model No. NTMKD2X18 Sliding Adjustable Shelf (1U) Used for 19 inch network cabinet. Main part: Description Size MM OPTICAL FIBER Parameter Model No. 1U Width Depth 2U Static load capacity: 30 Kg [66Lb] NT-SBP-1U 3U 482 44 Material: SPCC cold rolled steel NT-SBP-2U 4U Color:RAL7035 NT-SBP-3U 482 88 NT-SBP-4U RAL9004 482 132.5 482 177 Main part: Shelf size MM Use Model No. Description Width Depth NTVS1UX14ADJ 350 type 440 350 600~800MM cabinet NTVS1UX26ADJ 550 type 440 550 900~1100MM cabinet CABINETSpage 161 page 162

2N0IT1R6 ONTITERLOPTREOLDPURCOTDIUNCFOT RINMFAOTRIOMNATISOTNRCUACBTIUNREETSCABLING STRUCTCUARBEINCEATBSL2I0N1G6 NNITITRROOTTEELLPPRROODDUUCCTTININFFOORRMMAATTIOIONN LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING CABLE MANAGEMENT SCREWS & NUTS 1U Metal Cable 1U Metal Cable 10-32 Screws With Cage Nuts and Screws FACE PLATE Management With Cover Management Cushion Compatible with 19 inch network. Compatible with 19 inch network, metal cable management with 4 rings. Parameter Parameter Parameter Parameter MODULES Material: SPCC cold rolled steel. Material: SPCC cold rolled steel. Phillips Phillips /Trox Color:BLACK Color:BLACK Color:BLACK Color:Zinc-plated Main part: Size MM Main part: Size MM Main part: Main part: TYPE Packs of Trox(T30) 50 Model No. Width Height Model No. Width Height Model No. Packs of Model No. 50 NTCM1U NTCM4R1U NTS10-32 100 NT Phillips 482 80 482 68 700906002 1U Plastic Cable 1U Cable Management M6 Cushion T30 Trox Tool PATCH PANELS Management With Brush Compatible with 19 inch network, removable Plastic cable Compatible with 19 inch network. management with 5 rings. OPTICAL FIBER Parameter Parameter Parameter Parameter Material: SPCC cold rolled steel and plastic ring. Material: SPCC cold rolled steel+ brush. Used for M6 screws Used for M6 screws Color: BLACK ANODIZE. Color: BLACK. Material: ABS Size: φ5.5*33*120 Color: BLACK Color:Zinc-plated Main part: Main part: Main part: Main part: Model No. Size MM Model No. Size MM NTCMF5R1U NTBRP1U Model No. Model No. Width Height Width Hole NTCM6 Packs of NTTT30 Packs of 50 10 482 68 482 390X30 CABINETSpage 163 page 164

N20IT1R6 ONTITERLOPTREOLDPURCOTDIUNCFOT RINMFAOTRIOMNATISOTNRCUACBTIUNREETSCABLING STRUCTCUARBEINCEATBSL2I0N1G6 NNITITRROOTTEELLPPRROODDUUCCTTININFFOORRMMAATTIOIONN LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING ACCESSORIES PLINTH/DRAWER Earthing Kit Earthing Kit Plinth FACE PLATE Parameter Only for Nitrotel 19” cabinet, Static load capacity: 1000 Kg.[2200Lb] Material: SPCC cold rolled steel Color::RAL7035 :RAL9004 Main part: Model No. Shelf size MM Use MODULES Width Depth Height NTPL66S Parameter Parameter NTPL68S 600 600 100 Spark cabinet NTPL69S ROHS complied ROHS complied NTPL61S 600 800 100 Spark cabinet 14 AWG, 300MM length 14 AWG, 300MM length NTPL86S NTPL88S 600 900 100 Spark cabinet NTPL66N Main part: Main part: NTPL68N 600 1000 100 Spark cabinet NTPL69N NTPL61N 800 600 100 Spark cabinet NTPL86N Model No. Packs of Model No. Packs of NTPL88N 800 800 100 Spark cabinet NTGWK01 2 NTGWK02 2 600 600 100 Network cabinet 600 800 100 Network cabinet 600 900 100 Network cabinet 600 1000 100 Network cabinet 800 600 100 Network cabinet PATCH PANELS Castor Castor With Braking 800 800 100 Network cabinet Drawer Parameter OPTICAL FIBER Used for 19 inch network cabinet and rack. Static load capacity:35kg Sliding shelf could elongate to 450MM material: SPCC cold rolled steel Color: RAL7035 RAL9004 Parameter Main part: Static load capacity: 250kg Parameter Model No. Description Color: black/ Zinc-plated NTDR2UX18 2U-18” DP Static load capacity: 250kg NTDR3UX18 3U-18” DP Main part: Color: black/ Zinc-plated Main part: Model No. Type of Wheel Packs of Model No. Type of Wheel Packs of NTCF20 2.0 INCH 4 NTCFB20 2.0 INCH 4 NTCF25 2.5 INCH 4 NTCFB25 2.5 INCH 4 NTCF30 3.0 INCH 4 NTCFB30 3.0 INCH 4 CABINETSpage 165 page 166

NITROTEL PRODUCT INFORMATION STRUCTURE CABLING STRUCTURE CABLING NITROTEL PRODUCT INFORMATION LAN CABLE & PATCH CABLE CABINETS FITTING CABINETS FITTING LOCK LOCK Swing Handle with Lock Swing Handle With Combination Lock FACE PLATE Parameter Product Description Product Drawing Used for Nitrotel cabinet door Main material and finish: Black PA housing, handle Thickness of lock:30MM and knob, white zinc-plated steel cam and support. Hole size:126X24.5MM Color: BLACK Main part: Model No. Packs of MODULES NTSHL 3 3-Points Lock 180° Use key to open the lock,without password Parameter PATCH PANELS 180° Used for Nitrotel cabinet door Thickness of lock:20MM Enter password to open the lock,open lock with Hole size:Φ19X16.5MM password instead of key,original password:\"0,0,0” Main part: 15° Model No. Packs of Change the password(it is correct),when knob NT3PL 50 indlcates opening position,anti-clickwise rotation 15 degree to change the password M12 Leveling Feet Parameter OPTICAL FIBER Static load capacity: 250kg Color: black/ Zinc-plated Main part: Model No. Height MM Packs of NTLFM12 100 4 CABINETSpage 167 page 168


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook