A World Leader in Assisted & Long-Term Care Emergency Call Solutions
The TACERA Emergency Call SolutionTACERA is an IP-based Emergency Communications system that links residents, in real-time, with all Health Carepersonnel, support systems and internal processes responsible for their individual care and safety. TACERA willempower not overpower the caregiver with easy-to-use technology ensuring increased productivity and security. The TACERA Care and Communication RevolutionNo more unanswered resident calls, no more running around looking for caregivers. With TACERA, caregivers areprovided with actionable information and can respond instantly to residents’ needs, reducing risk and increasing bothresident and caregiver satisfaction. TACERA makes each wireless phone or tablet a full powered nurse station thatreleases nurses from their desk. TACERA offers the power of a nurse station with portability.Providing Total ReliabilityEmbracing IP-technology and state-of-the-art software, TACERAincorporates a comprehensive and flexible range of call types,priority levels, alarm handling and call indication options which areconfigurable to best suit the needs of residents and caregivers.Residents activate calls using aesthetically pleasing, unobtrusive andyet easy to identify call points that have been designed for ease ofuse by frail and aged residents, especially those with arthritis. Callpoints incorporate immediate audio visual indication to assure theresident that the call has been placed. One Easy-to-Use Platform. Advanced technologies delivering flexible communication solutions
Air Bubble Pendant Tacera»»Suitable for residents with restricted movement»»Soft Pneumatic Activation»»Waterproof»»Safe in Oxygen Rich environmentsAir Bubble Pendant 6.5 mm pendant socket connects The Austco Air Bubble Pendant is a large 80mm diameter soft to any callpoint touch, air-activated pad. It has been designed with the needs of ‘restricted movement’ residents in mind - for example Soft-touch air-activation those with arthritis.Easy to Identify and Use Only the slightest pressure is required from the resident to activate the device, thanks to the cleverly designed pneumatic activation. Available with an 8 foot lead, the Air Bubble Pendant integrates with the majority of Nurse Call systems, featuring a fully moulded industry standard 6.5mm jack. A pendant removal alarm ensures instant notification that a pendant is not available for your patient, reducing downtime The pendant is suitable for use by left and right handed patients and residents.Long Lasting Design The pendant itself is totally waterproof, completely safe in oxygen rich environments and is UL1069 listed. Each Air Bubble Pendant can be securely clipped to bedding or garments to ensure it stays within the resident’s reach. The easy release design protects the callpoint socket, pendant plug and cable from damage should the cable be placed under severe tension, such as moving the bed with the pendant still connected.To learn more about Austco products and solutions, visit Austcowww.austco.com or call to speak to our experts about acommunications solution for your facility.
Air Bubble Pendant Technical Specifications Feature Description Width 80mm diameter Weight 200 grams Mounting Method Connects to any Tacera callpoint with a Connectors 6.5mm pendant socket 6.5mm stereo jack Temperature 0…50˚C Humidity Range 0…85% Non CondensingAustco Compliance© 2013 Austco Marketing & Service (USA) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment.Austco Marketing & Service (USA) Ltd reserves the right to make changes • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalin specifications and/or discontinue any product at any time withoutnotice or obligation and will not be liable for any consequences resulting electrical equipment - Part 1: General requirements for safety.from the use of this publication. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code DescriptionCS-PMPAD Air Bubble Pendant Order OptionsUnited States Canada Latin America Authorized Austco Reseller8708 N. Royal Lane 60 Granton Drive, Unit 6 2010 Rossmore CtIrving TX 75063 Richmond Hill Ontario L4B 2N6 New Smyrna Beach FL 32168UNITED STATES CANADA UNITED STATES +1 972 929 0974 +1 905 731 1830 +1 407 574 7234 +1 972 929 0976 +1 905 731 1816 +1 407 574 7234www.austco.us www.austco.ca www.austco.com
Generic Callpoint Inserts Tacera» Changeable Inserts available in a number of standard AM-CPG-CP AM-CPG-LG AM-CPG-CP-T colours and icons for easy and fast identification AM-CPG-CC-T AM-CPG-SA AM-CPG-EM-T» Push and Back lit buttons available with horizontal and vertical text and icon order options AM-CPG-CN AM-CPG-SP AM-CPG-R» Hard-wearing and washable AM-CPG-Y AM-CPG-EM AM-CPG-CW Call Button Inserts AM-CPG-SP-T AM-CPG-B AM-CPG-CO Large and easy to activate, the Austco Call Button Inserts provide a positive tactile response when pressed. Callpoints are designed for changeable inserts in vertical or horizontal forms as shown in picture. The Call Button Insert design enables a facility to swap out and replace the current call button instead of needing to replace the whole callpoint. For example, if a facility had a Staff Assist Callpoint in a room and now wanted that callpoint to be an Emergency Callpoint, they simply swap out the staff Assist Insert button for an Emergency Call Insert and reconfigure to alert as an emergency call on the system when pressed. With this added flexibility and low maintenance feature the facility can work out which alerts need to be where long after the initial install. This helps to drive workflow efficiencies throughout their healthcare organisation thus increasing patient car Vertical Inserts AM-CPG-PC-T AM-CPG-CC AM-CPG-W AM-CPG-GAM-CPG-CR AM-CPG-CO-T AM-CPG-ME AM-CPG-O AM-CPG-CB-TAM-CPG-CW-T AM-CPG-SC AM-CPG-PC AM-CPG-CB AM-CPG-SA-TTo learn more about Austco products and solutions, visit Austcowww.austco.ca or call to speak to our experts about acommunications solution for your facility.
Generic Callpoint Inserts Horizontal InsertsAM-CPG-ME-H AM-CPG-CB-H AM-CPG-EM-H AM-CPG-R-H AM-CPG-CP-H AM-CPG-PC-T-HAM-CPG-CO-T-H AM-CPG-SA-T-H AM-CPG-CP-T-H AM-CPG-W-H AM-CPG-SC-H AM-CPG-SP-T-HAM-CPG-CC-T-H AM-CPG-CN-H AM-CPG-CR-H AM-CPG-PC-H AM-CPG-SP-H AM-CPG-CB-T-HAM-CPG-CW-H AM-CPG-CC-H AM-CPG-CO-H AM-CPG-Y-H AM-CPG-B-H AM-CPG-LG-H AM-CPG-G-H AM-CPG-O-H AM-CPG-CW-T-HAustco Compliance© 2013 Austco Marketing & Service (Canada) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment.Austco Marketing & Service (Canada) Ltd reserves the right to make • C-Tick Electromagnetic compatibility.changes in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalresulting from the use of this publication. electrical equipment - Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code Description Order OptionsAM-CPG Generic Callpoint Insert Vertical *Note: AM-CPG-H - Horizontal refers to when ordering H - (Horizontal) the horizontal hanging callpoints. Normal vertical hanging callpoints do not have a (H) when orderingCanada Authorised Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
LED Annunciator Tacera» Priority color coded calls 50mm high character Dots show number and display level of pending calls:» Automatic scrolling of multiple messages Green x Patient Call Orange x Staff Assist» Selectable sets of alert tone sound sequences Red x Emergency» Day / Night shift mode Custom designed message» Ceiling or wall mountable display Non-reflective displayLED Annunciator Automatic scrolling Front facing This high resolution, alphanumeric LED Annunciator provides with priority color speaker for audible audio and visual notification of active calls by means of text coded messages messages with accompanying alert tones based on priority. notification This IP-based device allows text messages, colors and tones to be completely configured for your facility. Multiple Discreet ceiling/wall Annunciators may be connected anywhere on the LAN. mounting bracket The alert tones and message colors for all call priorities can be customized to suit your facility. The Annunciator can be programmed to display messages from multiple areas, allowing calls to go to a specific unit displays and higher priority calls to go to adjacent unit or floor displays as required. Additionally, the Annunciators support ‘Unit Swinging’, allowing all calls from one unit to be diverted to a group of Annunciator displays.Information Easily Viewed from a Distance The AN-PD1 Annunciator uses 50mm tall, high-efficiency LED modules with a high resolution that ensures messages are easy to read from a distance of up to 20m. The Annunciator uses proportional fonts so that characters are only displayed at their required width rather than a fixed width. On average, the Annunciator displays 12 characters and automatically scrolls longer messages.To learn more about Austco products and solutions, visit Austcowww.austco.ca or call to speak to our experts about acommunications solution for your facility.
LED Annunciator The area to the right of the Annunciator displays a bar graph Technical Specifications of the number of active calls. Three vertical columns (red, orange and green) graphically display the type and number Feature of pending calls. Height 116mm When there are no active calls, the Annunciator can be configured to display the current time. Width 570mm DepthEasy to Program On-site Weight 35mm Wall Plate The Annunciator can be programmed on-site using a Connectors 350 grams configuration utility for parameters such as network address, node numbering, chime patterns, display colors and display Voltage Powder coated aluminium case brightness. These are downloaded into flash memory that Current ensures that the configuration data is retained, even in the Annunciator: Ethernet RJ-45 and modular RJ-12 event of power loss. Temperature Wall plate: Humidity Range Outside: Ethernet RJ-45 and modular RJ-12Clock Inside: Ethernet RJ-45 and 5 screw terminals (power and RS485 for legacy systems) When there are no calls to display, the Annunciator can be used to display a clock. 10-28V DCNight Mode 485mA @ 13.8V 290mA @ 24V To help minimise disturbing your patients when they are sleeping, the Annunciator can be programmed to soften the 0-50ÛC alert tones and dim the display in night mode. 0-85% Non CondensingMounting Being both ceiling and wall mountable, the unit is streamlined and ergonomically designed. They can be installed as a single unit or in parts, allowing the creation of dual-sided units for multi-directional access areas.Austco Compliance© 2013 Austco Marketing & Service (Canada) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility.Austco Marketing & Service (Canada) Ltd reserves the right to make • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalchanges in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences electrical equipment - Part 1: General requirements for safety.resulting from the use of this publication. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product CodeAN-PD1 Annunciator, Programmable Display, 12 Characters, three Colors, 50mm highCanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
Austco ARK-1 Nurse Call ApplianceFeatures and Benefits Compared to traditional Nurse Call Systems utilizing consumer grade equipment, which typically offer 3 year or less product lifecycles, theFirst of its kind Austco ARK-1 Nurse Call Appliance offers a guaranteed 5-year product lifecycle. Industrial grade Nurse Call systems need to operate reliably • The first Nurse Call Appliance for a long period of time in harsh environments, including extreme available on the market. temperatures, areas of electromagnetic interference (EMI), vibration, dirt, moisture and corrosion. It is important that operations personnelRuggedized for greater uptime purchase equipment specifically designed for these harsher environments and high availability. While traditional commercial • Built specifically for 24/7 mission critical solutions are ideal for low-reliability enterprise applications, they may not necessarily be designed to withstand severe conditions as those operations in extreme conditions of found in most healthcare environments. temperature, humidity and dust while providing a high level of reliability, With its small form-factor, the ARK-1 is ideal for facilities with limited robustness and performance. Use of all server space which do not want to sacrifice performance or durability. industrial grade components and fanless The ARK-1 can be rack or wall-mounted, is developed to Austco R&D design, the ARK-1 has been engineered specifications and is fully supported by Austco. for reliability in harsh environments. Austco’s newly released ARK-1 will supersede legacy ACS-110High Reliability and seamless hardware.Redundancy • The ARK-1 offers high availability and a long lifecycle, making it perfect for healthcare environments requiring complete reliability and high performance. • Austco’s ARK-1 is fully scalable and has the ability to perform as a primary and secondary node, providing full redundancy capabilities and reduced downtime. Availability January 1, 2018 www.austco.com L-194_Revision E
Specifications (includes AC adaptor)High Performance Industrial ComputingFeaturing an advanced industrial grade design incorporating a 2.7 GHz (Dual Core) Intel Core i5, 8GB DDR3, 32GB of SLC NANDStorage encased in an aluminum housing, the entire system is CB, UL, CCC, BSMI, and CE/FCC Class A rated with added protectionfrom shock, vibration, water and dust, making the ARK-1 the ideal system ensuring patient safety in a wide range of environmentsrequiring uninterrupted operation.Product Code Description Order OptionsIP-ARK-1 Appliance IP-ARK-1-RACK - Rack mount enclosure sold separately. Please contact your local Austco Representative for more details. www.austco.com L-194_Revision E
Breathcall®» Pneumatic device activated by patient's breath Breathcall Communicator» For patients with special needs (severe burns, paraplegics, provided by Curbell Medical quadriplegics, immobilized patients)» Adjustable clamp fits side rail or headboard» Arm can be adjusted to almost any position» Additional straws and filters availableThe BreathCall® Specialty Call CordThe BreathCall® communicator provided by Curbell is ideal forPatients and Residents with special needs such as paraplegics,quadraplegics and immoblized patients. The easily adjustableclamp fits side rails and headboards with an infinitely adjustablearm and a choice of straws and filters.BreathCall® FeaturesOur specialty call cords allow patients with limited or no handdexterity to signal the nurse or operate a TV using ultra-sensitiveswitches in a variety of forms. They can integrate with the TACERANurse Call system directly or with the use of a nurse call adaptor.BreathCall offers:• Easy Positioning - The flexible tube means that the Breathcall unit can be positioned to suit the individual and can be easily transferred from one position to another.• Pneumatic - The Breathcall unit can be used as an aid for communication for persons with limited mobility, who are unable to use a standard call cord. For example: paraplegic and quadriplegic individuals and those with severe arthritic and rheumatic conditions.• Easy Activation - Requiring only the lightest puff of air to activate, the Breathcall unit will then trigger the Alarm system or Nursecall system to alert the carer that assistance is required. To learn more about Austco products and solutions, visit www.austco.ca or call to speak to our experts about a communications solution for your facility.
CB-GEB-010 Breathcall Specialty Call Cord Technical SpecificationsThe Curbell air activated Breathcall is used for Feature 1/4\" plugpatients with li le or no motor s ills and is activated Plug Typeby simply breathing into a disposable straw and filterassembly. Works with TACERA Nurse Call System Descripton 9' Product Code CB-GEB-010Product CodeCB-GEB-010© 2013 Austco Marketing & Service (Canada) Ltd ComplianceAll rights are reserved. Designed to comply with:Austco Marketing & Service (Canada) Ltd reserves the right to make • UL 1069 Hospital Signaling and Nurse Call Equipment.changes in specifications and/or discontinue any product at any time • C-Tick Electromagnetic compatibility.without notice or obligation and will not be liable for any consequences • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalresulting from the use of this publication. electrical equipment - Part 1: General requirements for safety.Product Code Breathcall Specialty Call Cord • CE Mark of European Conformity.CB-GEB-010 Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. N/ACanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
IP Call Pendant Tacera»»Ergonomic, palm-sized pendant with bed clip»»Durable fully moulded fittings»»Integrates with most existing Nurse Call systems»»Embossed Braille characters for the visually impaired»»Choice of button color and cable lengthIP Call Pendant 6.5mm pendant socket connects The Austco range of call pendants have been ergonomically to any callpoint designed, ensuring the devices are easy for patients / residents to hold and activate. The button is available in a Optional button color and cable choice of colors and the entire pendant is manufactured from length impact resistant plastic that is durable and easy to clean. Embossed Braille lettering The pendant socket incorporates a pendant removal alarm, to ensure that the pendant is not inadvertently unplugged. The pendant is suitable for use by left and right handed patients and residents.Easy to Identify and Use The palm-sized design fits comfortably in your patient’s hand. The textured and colored button assists sight impaired patients, and is easy to activate, making it suitable for use by the infirm or patients with manipulative disabilities. Additionally, all pendants are embossed with Braille lettering to assist the visually impaired.Long Lasting Design The casing is manufactured from white, durable, impact- resistant plastic. The cable has a strong, moulded plastic, right-angle plug that connects to any callpoint with a 6.5mm pendant socket. The easy release design protects the callpoint socket, pendant plug and cable from damage should the cable be placed under severe tension, such as moving the bed with the pendant still connected.To learn more about Austco products and solutions, visit Austcowww.austco.ca or call to speak to our experts about acommunications solution for your facility.
IP Call Pendant Technical Specifications Feature Description Height 95mm Width 40mm diameter Weight Mounting Method 165 grams Housing Connects to any Tacera callpoint with a Connectors 6.5mm pendant socket Cable Plastic Moulding Temperature Humidity Range 6.5mm stereo jack 2m of 3-core multi-strand, double insulated, white PVC cable with a plastic linen clip attached 0-50˚C 0-85% Non CondensingAustco Compliance© 2013 Austco Marketing & Service (Canada) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility.Austco Marketing & Service (Canada) Ltd reserves the right to make • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalchanges in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences electrical equipment - Part 1: General requirements for safety.resulting from the use of this publication. • CE Mark of European Conformity. Manufactured in general accordance with the requirements ofProduct Code Description international quality assurance standard ISO9002.CM-PM/xx Pendant, Momentary Action, 2mCP-Holder Pendant/Handset Holder Order Options GB – (Green Button) OB – (Orange Button) /B – (Red Button) Cable Length: For extra cable length, add /4M for 4m e.g. CM-PM/xx/4MCanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
ErgoPlus Patient Call Pendant»»Reassurance indication and large back-lit buttons Tacera»»Ergonomic all-in-one design that is easy to grip»»Embossed Braille characters for the visually impaired Large back-lit buttons»»Improved infection control Call Button»»Dip sterilizable (IP67) Non-slip caseErgoPlus Patient Call Pendant Anti-bacterial An ergonomically designed, easy-to-grip pendant for patients protection to activate calls on the Tacera Nurse Call System. The solid blue, water resistant case is non-slip and dip sterilizable, and AAuussttccoo is available with or without lighting controls. The soft touch buttons are recessed to avoid accidental activation. The entire pendant is manufactured from silicone rubber with an anti- bacterial additive for improved infection control. The pendant socket incorporates a pendant removal alarm, to ensure that the pendant is not inadvertently unplugged. It is suitable for use by left and right handed patients. The Nurse Call and light control buttons are large, backlit for ease of use at night and with Braille dots on the CALL button for easy identification by the visually impaired. The non-slip case and large linen clip on the cable ensure that the pendant does not slip off the bed and is always at hand for your patient.Easy to Identify and Use A simple patient pendant that provides your patient with a call button to activate calls on the Tacera Nurse Call System. It is available with or without patient control of lights. The unique shape and ergonomic design fits comfortably in your patient’s hand. Textured, colored, back-lit buttons avoid confusion and assist visually impaired patients, especially at night and in low light conditions.To learn more about Austco products and solutions, visitwww.austco.ca or call to speak to our experts about acommunications solution for your facility.
ErgoPlus Patient Call Pendant The buttons on the ErgoPlus Patient Call Pendant are easy to Technical Specifications activate and are suitable for use by the infirm or patients with manipulative disabilities. Feature Description Height 110mm Long Lasting Design Width 50mm Manufactured from silicone rubber, the solid blue case has Depth an all-in-one design that is robust and durable. The cable Weight 25mm is manufactured from multi-strand, double insulated, white Mounting Method PVC cable and includes a large, smooth plastic linen clip that, 165 grams together with the non-clip case, helps keep the pendant within Housing easy reach of your patient. Connectors Connects to any Tacera callpoint fitted with a Temperature 6.5mm pendant socket The easy release design of the moulded right-angle plug Humidity Range protects the callpoint socket, pendant plug and cable from Cable Anti-bacteria silicone case damage should the cable be placed under tension, such as moving the bed with the pendant still connected. 6.5mm stereo jackImproved Infection Control 0-50˚C 0-85% Non Condensing The pendant has an IP67 rating, allowing it to be dip sterilised for easy cleaning after patient use. The soft touch silicone 2m of 3-core multi-strand, double insulated, case and buttons have an anti-bacterial additive for improved white PVC cable with a plastic linen clip infection control. attachedLight Control Up to 2 lights can be controlled by the press on the left or right of the light control button. One press ON, second press OFF. A dual relay is used to control the lights.Austco Compliance© 2013 Austco Marketing & Service (Canada) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility.Austco Marketing & Service (Canada) Ltd reserves the right to make • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalchanges in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences electrical equipment - Part 1: General requirements for safety.resulting from the use of this publication. • CE Mark of European Conformity. Manufactured in general accordance with the requirements ofProduct Code Description international quality assurance standard ISO9002.CP-PCP/xx Patient Call Pendant with Light Control, 2mCP-SCP/xx Patient Call Pendant, 2m Order Options Pendant/Handset Holder GB – (Green Button)CP-Holder OB – (Orange Button) Cable Length: For a 4m cable length, add /4M e.g. CP-PCP/xx/4MCanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
IP TALKTWO INTERCOM MODULE IP-TALKTWO/VOIP• Full-duplex speech capability Impact• VoIP communications powered by PoE resistant ABS• Web-based setup interface• Integrated with the Tacera Nurse Call System plastic• Active call indicator SpeakerTalkTwo/VoIPA flush mounted intercom module that provides full-duplexaudio communication between healthcare staff andpatients/residents in their room. It is integrated with theTacera Nurse Call System to provide seamlesscommunication to a specific location when an alarm isactivated.The intercom fits into a standard electrical wall box forquick and easy installation. Manufactured from an impactresistant polycarbonate / ABS plastic blend, the intercomfeatures mounting hardware to maximize the life of themodule.Two-way Audio CommunicationWhen a patient or resident activates a callpoint, the nursecall system displays the alarm with the extension numberof the room where the alarm was activated. By clicking onthe extension number on either the nurse station or themobile app, a voice call is connected to the room. Microphone Active call indicatorwww.austco.com CS-005, Rev. B
SPECIFICATIONSFeature c i tionHeight 116 mm (4.57 in) 76 mm (2.99 in)Width epth 45 mm (1.77 in) 5.29 ozWeight Screw onMounting Austco Modular PlatePlate Standard Size Wall BoxWall Box SizeHousing Wall BoxConnectors Modular P CCable CAT STP cableTemperature 0 - 50 C umidity Range 0- 5 Non CondensingPower PoE 0 . af or later powerCompliance CSA . No. - - - Audio/Video, Information and Communication Technology Equipment - Part Safety Requirements EN 550 0 5 Electromagnetic Compatibility of Multimedia Equipment EN 550 5 0 Electromagnetic Compatibility of Multimedia Equipment - Immunity Requirements EN 000- - 0 Electromagnetic compatibility EMC . imits. imits for harmonic current emissions equipment input current A per phase EN 000- - 0 Electromagnetic Compatibility EMC - PART - imits - imitation of Voltage Changes, Voltage luctuations and licker in Public ow-Voltage Supply Systems, for Equipment with Rated Current A Per Phase and Not Sub ect to Conditional Connection CE Mark European Conformity IEC - Audio/video, information and communication technology equipment - Part Safety requirements RCM Regulatory Compliance MarkORDERING INFORMATIONProduct Code c i tion Ord tionIP-TALKTWO/VoIP IP TalkTwo VoIP Intercom N/AIP-TA TW /VoIP/BS IP TalkTwo VoIP Intercom, British Style N/A 0 Austco Communications Systems PT td.All rights are reserved.Austco Communications Systems PT td. reserves the right to take changes in specifications and/or discontinue any product at any time without notice orobligation and will not be liable for any consequences resulting from the use of this publication. www.austco.com
IP Generic Callpoint » Hard-wearing and washable (IP65 Rated) Tacera » Anti-bacterial protection with Infection Control Anti-bacterial protection » Fully Supervised Callpoint, with backlight Optional 6.5mm Pendant Socket » Pendant Removal Alarm Bright reassurance LED Optional 8 pin DIN Pendant Socket » “Three Button Press” for Emergency Calls for TV control CHANGEABLE INSERTS IP Generic Callpoint MUST BE ORDERED SEPARATELY Large and easy to activate, the Austco silicon call button provides a positive tactile response when pressed. This makes it ideal for patient/ residents with restricted or limited movement. Standard features include back lit buttons for night viewing by residents and patients, a reassurance LED and tone sounder for audibly or visually impaired patients, and call mute mode for cleaners. Callpoints are designed for changeable inserts as shown in picture. The call button insert design enables a facility to swap out and replace the current call button instead of having to replace the whole Callpoint. For example, if a facility had a Staff Assist Callpoint in a room and they wanted the Callpoint to be an Emergency Callpoint, they simply swap out the Staff Assist button for an Emergency Call button insert and reprogramme to alert as an emergency call on the system when pressed. With this added flexibility and low maintenance feature the facility can work out which alerts need to be where long after the initial install to drive efficiencies throughout their organisation thus increasing patient care. Lower “Whole-of-Life” Costs IP Generic Callpoints are IPnet and feature plug-and-play functionality. They are connected in series using standard CAT5/6 cable that also provides POIPnet (Power Over IPnet). Each callpoint has a unique address and is supplied configured for immediate use. Once connected, the callpoint is quickly and easily assigned to a room using a browser, which simplifies the installation process and reduces the cost of installation and commissioning.To learn more about Austco products and solutions, visitwww.austco.ca or call to speak to our experts about acomTmo ulenaicrnatmionosresaobluotuiotnAufosrtcyoouprofdauciclittsy.and solutions, visit
IP Generic Callpoint The system continuously checks the functionality of each callpoint To avoid nuisance alarms during cleaning, the callpoint and will immediately notify staff if any problem is detected. Callpoints incorporates a cleaning mode. The cleaning time and date is are hot swappable, making maintenance a breeze, simply replace a logged on the central server, providing an important audit trail for callpoint and then use a browser to quickly configure the device. infection control compliance.Easy to Identify and Use Over Bed Indicator IP Generic Callpoints feature soft-touch push buttons that are clearly An over bed indicator can be added to display the call status. labelled with text or icons for easy and fast identification. The CALL button insert is available in a number of standard colors and icons, Technical Specifications allowing the system to operate a variety of alarm levels and system inputs as determined by the protocols of your facility. Feature 116mm (Australian/New Zealand Plate) Height The callpoint can be configured to allow active calls to be upgraded to a higher level by pressing the CALL button three times or holding it for Width 76mm (Australian/New Zealand Plate) three seconds. This feature can eliminate the need for separate staff Depth assist buttons thus further reducing infrastructure costs. 26mm (Standard) Weight 37mm (With pendant socket) All callpoints are available with an optional socket for a Call Pendant Mounting Method or Patient Entertainment Handset. Users can easily initiate a call by 70 grams pressing the CALL button on a plug-in pendant or the callpoint. Screw on All callpoints are connected on the Nurse Call LAN to all other components of the Tacera system to initiate communication between Plate Austco Modular Plate nursing staff and patients. Wall Box Size Housing Standard Australian/New Zealand Size Wall BoxImproved Infection Control Connectors Wall Box These ergonomic callpoints are flush, wall mounted with a Cable configurable CALL button. Each callpoint has a separate CANCEL button Ipnet: 2xR5-45 socket that illuminates red, giving visual reassurance that a call has been Temperature Over bed indicator: 2-pm screw terminal initiated. Both buttons are manufactured from silicone rubber with an Humidity Range (AWG 24) anti-bacterial additive for improved infection control. CAT5 or CAT6 modular cable (AWG 24) Data / Security cable to over bed indicator light 0-50 C 0-85% Non Condensing© 2013 Austco Marketing & Service (Canada) Ltd ComplianceAll rights are reserved. Designed to comply with:Austco Marketing & Service (Canada) Ltd reserves the right to make • UL 1069 Hospital Signaling and Nurse Call Equipment.changes in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences • C-Tick Electromagnetic compatibility.resulting from the use of this publication. • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medical electrical equipment - Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code Callpoint General onlyIP-CPG Callpoint with Pendant Socket Callpoint with Entertainment Handset OutletIP-CPG/PIP-CPG-EHOCanada ote See inserts cut sheet or op ons Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
IP Water Resistant Callpoint Tacera» Maintains reliability in harsh wet areas Anti-bacterial protection» Hard-wearing and washable (IP65 Rated)» Anti-bacterial protection with Infection Control» Three Button Press for Staff Assist or Emergency CallsIP Water Resistant Callpoints Inserts must be ordered separately Large and easy to activate, the Austco silicon call button provides a positive Bright Reassurance LED tactile response when pressed. This makes it ideal for patient/residents with restricted or limited movement. Water resistant infront and behind the Standard features include back lit buttons for night viewing by residents and callpoint patients, a reassurance LED and tone sounder for audibly or visually impaired patients and call mute mode for cleaners. Callpoints are designed with changeable inserts (see IP-CPG and Inserts cutsheet for further order options). Water resistant callpoints are supplied with a silicone rubber boot that ensures an IP65 rating for any callpoint (without an optional pendant socket) installed in ensuites, toilets and other wet areas. To ensure an IP65 rating, water resistant callpoints can only be installed as single-gang. The silicone rubber boot seals the callpoint at the back (where moisture ingress normally occurs) and between the wall plate and wall. To prevent corrosion and ensure that every water resistant callpoint installed in a harsh wet area remains reliable, each water resistant callpoint is also supplied with; • Stainless steel screws and O-rings, and • Silicone inserts to seal all screws holes.Lower “Whole-of-Life” Costs IP Water Resistant Callpoints are IPnet and feature plug-and-play functionality. They are connected in series using standard CAT5/6 cable that also provides POIPnet (Power Over IPnet). Each callpoint has a unique address and is supplied configured for immediate use. Once connected, the callpoint is quickly and easily assigned to a room using a browser, which simplifies the installation process and reduces the cost of installation and commissioning.To learn more about Austco products and solutions, visit Austcowww.austco.ca or call to speak to our experts about acommunications solution for your facility.
IP Water Resistant Callpoint The system continuously checks the functionality of each callpoint and Technical Specifications will immediately notify staff if any problem is detected. Callpoints are hot swappable, making maintenance a breeze, simply replace a callpoint and then Feature eƐcrŝƉƟoŶ use a browser to quickly configure the device. Height 116mm (Australian/New Zealand Plate)Easy to Identify and Use Width 76mm (Australian/New Zealand Plate) Depth IP Water Resistant Callpoints feature soft-touch push buttons that are clearly 26mm (Standard) labelled with text or icons for easy and fast identification. The CALL button Weight 37mm (With pendant socket) is available in a number of standard colours and icons, allowing the system Mounting Method to operate a variety of alarm levels and system inputs as determined by the 70 grams protocols of your facility. Screw on The callpoint can be configured to allow active calls to be upgraded to a higher level by pressing the CALL button three times or holding it for three seconds. Plate Austco Modular Plate This feature can eliminate the need for separate staff assist buttons thus further Wall Box Size reducing infrastructure costs. Housing Standard Australian/New Zealand Size Wall Box Connectors These ergonomic callpoints are flush, wall mounted with a configurable CALL Wall Box button. Each callpoint has a separate CANCEL button that illuminates red, giving Cable visual reassurance that a call has been initiated. All callpoints are connected Ipnet: 2xR5-45 socket on the Nurse Call LAN to all other components of the Tacera system to initiate Temperature External lamp indicator: 2-pm screw terminal communication between nursing staff and patients. Humidity Range (AWG 24)Improved Infection Control CAT5 or CAT6 (AWG 24) Data / Security cable to over bed Both buttons are manufactured from silicone rubber with an anti-bacterial indicator light additive for improved infection control. 0-50ÛC 0-85% Non CondensingTo avoid nuisance alarms during cleaning, the callpoint incorporates a cleaningmode. The cleaning time and date is logged on the central server, providing animportant audit trail for infection control compliance.External Lamp Indicator An over door lamp indicator can be added to display the call status.Austco Compliance© 2013 Austco Marketing & Service (Canada) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility.Austco Marketing & Service (Canada) Ltd reserves the right to make • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalchanges in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences electrical equipment - Part 1: General requirements for safety.resulting from the use of this publication. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code eƐcrŝƉƟoŶ Krder KƉƟoŶƐIP-CPG/WR IP Callpoint, Water Resistant H - (Horizontal Callpoint) *Note: All Water Resistant Tacera Callpoints and Pull Cord Callpoints are supplied with a silicone boot and single-gang surroundCanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
IP IN8 Input Bridge Tacera»»Integrates third party clinical systems with Tacera»»Over door lights and audible chimes may be activated from the input bridge»»Alarm details may be relayed to pagers, wireless telephones, bridges and LCD annunciators»»Easy to install with CAT5/6 cable Allows both messaging and relay output events to be actionedIP IN8 Input BridgeThe IP IN8 Input Bridge enables up to eight external devicessuch as patient monitors, ventilators, IV pumps, pulseoximeters, room sensors, access control sensors and alarmsto be interfaced into Tacera.An integral buzzer sounds when the bridge is first connectedto an IPnet Router, giving the installer reassurance that thedevice has been and is functioning.Lower “Whole-of-Life” CostsThe IP IN8 Input Bridge is IP-based and features plug-and-play functionality. Bridges are connected in series using onlystandard CAT5/6 cable that also provides POIPnet (Power OverIPnet).Each bridge has a unique address that is used to identify More than one input can trigger athe device on the IPnet Router. Once connected, the device common event or outputis assigned an IPnet address then each input is quickly andeasily assigned to a room or area and function using a browser. Easy to install withThis simplifies the installation process and reduces the cost of CAT5/6 cableinstallation and commissioning.The system continuously checks the functionality of eachbridge and immediately notifies staff if any problem isdetected. Bridges are hot swappable, making maintenance abreeze – simply replace a bridge and then use a browser toconfigure the device.To learn more about Austco products and solutions, visit Austcowww.austco.com or call to speak to our experts about acommunications solution for your facility.
IP IN8 Input BridgeIndividual Control Technical Specifications There are eight independent, voltage free inputs that can be Feature Description individually set as normally open (NO) or normally closed (NC) Height 77mm using a browser. Width 112mm Safe and Reliable Depth 36mm Weight 110 grams The 3.5KV electrical isolation between the bridge inputs and Housing Plastic enclosure the IPnet ports maintain compliance with IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic Mounting Method Surface mount. 2 holes 122mm centres safety and essential performance. Current Consumption 15mA at 24V nominal To ensure reliability, the bridge has been designed and Voltage manufactured for immunity against voltage spikes and static Connectors IPnet - 8-30V DC charges, the most common causes of electronic failure. Temperature IPnet - 2 x RJ-45 socket Humidity Range Inputs - 16 screw terminals for 8 isolated Cable Sizes inputs Inputs - 16 screw terminals for 8 inputs 0…85% Non Condensing IPnet - CAT5, CAT5E, CAT6, CAT6E Inputs - 2 core (AWG 18-24) security cable for each call inputAustco Compliance© 2013 Austco Marketing & Service (USA) Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility.Austco Marketing & Service (USA) Ltd reserves the right to make changes • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalin specifications and/or discontinue any product at any time withoutnotice or obligation and will not be liable for any consequences resulting electrical equipment - Part 1: General requirements for safety.from the use of this publication. • CE Mark of European Conformity. Manufactured in general accordance with the requirements ofProduct Code Description international quality assurance standard ISO9002.IP-IN8 IP IN8 Input Bridge Order OptionsUnited States Canada Latin America Authorised Austco Reseller8708 N. Royal Lane 60 Granton Drive, Unit 6 2010 Rossmore CtIrving TX 75063 Richmond Hill Ontario L4B 2N6 New Smyrna Beach FL 32168UNITED STATES CANADA UNITED STATES +1 972 929 0974 +1 905 731 1830 +1 407 574 7234 +1 972 929 0976 +1 905 731 1816 +1 407 574 7234www.austco.us www.austco.ca www.austco.com
Zone Tone Sounder»»Adjustable volume level depending upon time of day Tacera»»Unique audio tones identify call type Selectable set of alert tones»»Selectable sets of alert tone sound sequences that Easy to install Area for optional replicate the Annunciator mute button»»Easy to install with CAT5/6 cable AustcoZone Tone Sounder A wall or ceiling mounted speaker that is used to audibly annunciate active calls in an area on the Tacera Nurse Call System. It is typically used in conjunction with an audio / visual Annunciator, and located in areas where the Annunciator cannot be seen or heard. The Zone Tone Sounder fits into standard electrical wall boxes, reducing installation times and costs. Manufactured from an impact resistant polycarbonate / ABS plastic blend, the sounder features concealed fixings to maximize the life of the sounder and reduce maintenance costs.Lower “Whole-of-Life” Costs The Zone Tone Sounder is IP-based and features plug-and- play functionality. It is connected in series using only standard CAT5/6 cable that also provides POIPnet (Power Over IPnet). Each sounder has a unique address and is supplied configured for immediate use. Once connected, the sounder is quickly and easily assigned to a zone / area using a browser, which simplifies the process and reduces the cost of installation and commissioning. The system continuously checks the functionality of each device and will immediately notify staff if any problem is detected. The Zone Tone Sounder is hot swappable, making maintenance a breeze – simply replace a sounder and then use a browser to configure the device.To learn more about Austco products and solutions, visitwww.austco.com or call to speak to our experts about acommunications solution for your facility.
Zone Tone SounderEasy to Hear Technical Specifications This sounder incorporates a speaker that provides clear, Feature Description undistorted audio that replicates the Annunciator audio Height 116mm (American/Canadian Plate) sequence, allowing staff to quickly identify the type of active call. Width 76mm (American/Canadian Plate) Depth 245mm An external mute button can be connected for maximum Weight 150 grams flexibility for your facility, the volume can also be software Mounting Method Screw on programmed (during commissioning) for time of day and or shift. Plate Austco Modular Plate Wall Box Size Standard North American size wall box All sounders are connected on the IPnet patient area network Housing Wall Box to all other components of the Tacera system. Connectors Modular In/out to IPnet Patient Area Network Temperature 0…50˚CLarger Areas Humidity Range 0…85% Non Condensing Cable Sizes CAT5 or CAT6 modular cable (AWG 26) The Zone Tone Sounder can be connected to multiple chime speakers with amplifiers to extend the area of notification such as a whole ward.Austco Compliance© 2013 Austco Communication Systems Pty Ltd Designed to comply with:All rights are reserved. • UL 1069 Hospital Signaling and Nurse Call Equipment.Austco Communication Systems Pty Ltd reserves the right to make • C-Tick Electromagnetic compatibility.changes in specifications and/or discontinue any product at any timewithout notice or obligation and will not be liable for any consequences • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medicalresulting from the use of this publication. electrical equipment - Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code Description Order OptionsIP-ZTS IP Zone Tone Sounder with Chime and SpeakerIP-AM-CSP Chime Speaker with Amplifier Note: Tacera Zone Tone Sounders do not include surrounds.United States Canada Latin America Authorized Austco Reseller8708 N. Royal Lane 60 Granton Drive, Unit 6 2010 Rossmore CtIrving TX 75063 Richmond Hill Ontario L4B 2N6 New Smyrna Beach FL 32168UNITED STATES CANADA UNITED STATES +1 972 929 0974 +1 905 731 1830 +1 407 574 7234 +1 972 929 0976 +1 905 731 1816 +1 407 574 7234www.austco.us www.austco.ca www.austco.com
IP‐CCT – Room Controller Control and power up to 32 IPnet devices Features Control and power up to 32 callpoints, Over Door Lights and Zone Sounders Fail‐safe operation ‐ operates independently of server Browser based configuration for on‐site Remote diagnostics remote configuration and diagnostics Standard Cat5/6 cabling Standard Cat5/6 cabling Room Controller The Room Controller is a sophisticated callpoint concentrator and acts as a router between your Austco LAN and the callpoint LAN. The Room Controller has been engineered to operate independently of the primary nurse call server, ensuring fail‐safe operation of callpoints, Over Door Lights and zone tone sounders. The Room Controller can manage up to 32 IPnet devices, with up to eight inputs per device. For maintenance it is recommended to manage up to 30 devices and keep two spare. The Controller provides Ethernet functionality with monitored and fused power over Cat5/6 cable for all IPnet devices. On‐board status LEDs provide visual confirmation of a network connectivity and normal operating current and voltage. Callpoint priorities and the level of call (bed, toilet, staff assist, emergency, etc.) can be independently programmed for each IPnet device or callpoint. Power for the Room Controller is provided by a battery backed power supply and the POIPNet (Power Over IPnet) circuits are both monitored and managed for voltage and current. IP Connectivity for True Integration The Room Controller is quick to install and easy to commission. When connected to the server, it is automatically assigned a unique address, integrating the router into your facilities’ network infrastructure is straightforward and it is continuously monitored for connectivity. www.austco.com
IP‐CCT – Room Controller Sophisticated Processing & Priority Management Reduced Ongoing Maintenance The Room Controller is an advanced call processor, The system continuously checks the functionality of each supporting specialized features above and beyond device and immediately notifies staff if any problem is traditional nurse call systems. These advanced features detected. IPnet devices are hot swappable, making include: maintenance a breeze. Simply replace a device and then Automatic Callpoint Call Upgrade. The automatic use a browser to quickly configure the device. The callpoint upgrade function will upgrade callpoints browser also provides access to an event log for use as a within the room, when a specific callpoint is activated. service tool for network testing. For example, Patient callpoints may be upgraded to Staff Assist callpoints when Nurse Presence is activated. Callpoint Call Upgrade. Callpoints may be configured to Technical Specifications be upgraded to another call type should the callpoint be pressed three times in quick succession or if the Feature Description callpoint is pressed and held for a specified duration. Protected Callpoints are isolated from function unless Height 56 mm (2.20 in) another call point is activated within the room. For example, the “Transport Required” callpoint may be Width 192 mm (7.56 in) disabled unless “Nurse Presence” has been activated. Cleaning Mode. By pressing and holding the Cancel Depth 132 mm (5.20 in) Button on a callpoint, the callpoint enters a cleaning mode which temporarily disables the button Weight 750 g (26.46 oz) functionality to permit cleaning. The Multi Cancel function enables a single cancel Mounting Method Surface mount enclosure button to cancel any number of active callpoints. For example, once a Nurse Presence button has been Connectors Power – plug‐in screw pressed in a multi‐bed environment, all existing patient terminal calls may be cancelled within the room. IPnet – 2 x RJ45 socket Ethernet – 2 x RJ45 Fault Monitoring Cable Power – 2 core (15AWG) IPnet devices are monitored for faults. The Room Cat5 or Cat6 Controller monitors itself for temperature and voltage out of range. Additionally, the Room Controller enables Voltage 18–28 V DC audible tones to be configured on‐site, to match your existing nurse call system and dynamically adjust the Temperature 0–50˚C (32–122˚F) volume levels based on day or night configuration. Humidity Range 0–85% Non‐condensing Multinode Room Controllers work with each other to allow for cross sounding and over door lighting. Reduced Cost of Installation and Commissioning The Room Controller is commissioned and managed using a standard browser allowing on‐site or remote programming. The plug‐and‐play capability of Tacera IPnet devices Compliance ensures that when connected, each device is automatically identified for default configuration, Designed to comply with: simplifying the installation process and reducing the cost of installation and commissioning. • AS 3811:1998 Hard‐wired patient alarm systems for hospitals. • AS 2999:1989 Alarm systems for the elderly and other persons at risk. • HTM 08‐03: Bedhead services. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C‐Tick Electromagnetic compatibility. • IEC 60601‐1, UL 60601‐1 and CAN/CSA C22.2 No. 601.1‐ M90: Medical electrical equipment ‐ Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. Description Order Options Product Codes Room Controller (30 Devices) (Product Family: Tacera) IP‐CCT Terms & Conditions: For specific terms and conditions related to this product and other company products, please refer to the company website www.austco.com 2015‐10‐26
IP Pull Cord Callpoint»» Low activation force Tacera»» Easy to clean vinyl cable prevents spread of bacteria»» Suitable for wet areas Low activation»» To prevent damage strain relief will break above a force 10kg loadIP Pull Cord Callpoint Clear colours and concise labels Water resistant, wall or ceiling mounted callpoints that initiate calls on the Tacera Nurse Call System. The cord has a wipe-clean surface and has its own strain relief to ensure reliable operation without any possibility of damage. Standard features include a reassurance LED, tone sounder for audibly or visually impaired patients and call mute mode for cleaners. Pull Cord Callpoint fits into standard electrical wall boxes, reducing installation times and costs. Manufactured from an impact- resistant polycarbonate / ABS plastic, all Pull Cord Callpoints feature concealed stainless steel fixings to maximize the life of the callpoint and reduce maintenance costs.Lower “Whole-of-Life” Costs Pull Cord Callpoints are IPNet and feature plug-and-play functionality. They are connected in series using only standard CAT5/6 cable that also provides POIPNet (Power Over IPNet). Each callpoint has a unique address and is supplied configured for immediate use. Once connected, the callpoint is quickly and easily assigned to a room using a browser, which simplifies the process and reduces the cost of installation and commissioning. The system continuously checks the functionality of each device and immediately notifies maintenance staff if any problem is detected. Pull Cord Callpoints are hot swappable, making maintenance a breeze – simply replace a callpoint and use a browser to quickly configure the new device.To learn more about Austco products and solutions, visit Austcowww.austco.ca or call to speak to our experts about acommunications solution for your facility.
IP Pull Cord Callpoint These callpoints feature a pull cord with handle that is brightly Feature 116mm (Australian/New Zealand Plate) HeightWater Resistant Width 76mm (Australian/New Zealand Plate) Depth 26mm (Standard) Pull Cord Callpoints are typically installed in bathrooms, toilets 37mm (With pendant socket) and other wet areas, so are supplied with a water resistant Weight 70 grams the callpoint at the back (where moisture ingress normally Screw on occurs) and between the wall plate and wall. Plate Wall Box Size Austco Modular Plate Standard Australian/New Zealand Size Wall Housing Box Connectors Wall Box IPNet: 2xR5-45 socketThese ergonomic callpoints are wall or ceiling mounted with a Cable Over bed indicator: 2-pm screw terminalcontrol. Each wall mounted Pull Cord Callpoint has a separate (AWG 24) Temperature CAT5 or CAT6required for ceiling mounted Pull Cord Callpoints. Humidity Range (AWG 24) Data / Security cable to over bed indicator light 0-50˚C 0-85% Non Condensingcords with a user friendly vinyl pull cord.To avoid nuisance alarms during cleaning, the callpointlogged on the central server, providing an important audit trailAustco Compliance 2017All rights are reserved. Designed to comply with: • UL 1069 Hospital Signaling and Nurse Call Equipment. • C-Tick Electromagnetic compatibility. • IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90: Medical electrical equipment - Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002.Product Code IP Pull Cord Callpoint, “C” on cancel button, Green fly leadIP-CPG-PC/GIP-CPG-PC/R IP Pull Cord Callpoint, “C” on cancel button, Red fly lead *Note: Cord sold seperatelyCanada Authorized Austco Reseller60 Granton Drive, Unit 6Richmond Hill Ontario L4B 2N6CANADA +1 905 731 1830 +1 905 731 1816www.austco.ca
IP‐EMH – Entertainment Multifunction Hand set Features Five discrete Nurse Call Buttons Integrated digital VoIP Intercom Entertainment and TV Buttons and sound Four Environmental Buttons Nurse Call 4 assistance call buttons Integrated Torch TV keypad Environmental Torch Infection Control Controls Entertainment & TV Controls Multifunction Entertainment Handset The IP‐EMH Multi‐function entertainment handset provides comprehensive Nurse Call, VoIP intercom, TV controls with sound, entertainment and environmental controls. Designed to fit comfortably in the patients hand or lay on the pillow, the integrated TV sound and intercom provides ease of conversation with the patient and minimizes TV volume in the room. Nurse assist provides resource savings in calling the right staff for the task. IP‐EMH /GR/ENT/DIN8 Clear Two‐way Audio Communication The IP‐EMH incorporates a microphone and speaker that provide both full‐duplex audio communication via a SIP VoIP exchange. A patient speech point on the pillow offers many benefits for both staff and patients. Knowing the patients’ needs before walking to the patient’s room, saves staff valuable time. When a patient/resident activates a nurse call request, a message is immediately dispatched to the appropriate pager, SMS or wireless phone, inclusive of the resident’s details and telephone extension, allowing staff to contact the patient directly from their smart device or wireless phone. Audio at the bedside increases your patients’ safety as staff will be able to hear immediately if a patient is at risk, has fallen or non‐responsive. This allows staff to take appropriate action immediately, saving precious time in an emergency. Easy to Identify and Use The design fits comfortably in your patient’s hand with back‐lit IP‐EMH/GR/TV/DIN8 IP‐EMH/GR/TVB/DIN8 buttons to assist sight impaired patients, especially at night in low‐light conditions. It also incorporates a lifetime LED torch www.austco.com
IP‐EMH – Entertainment Multifunction Handset in the body of the handset. Technical Specifications The handset’s flush soft touch keyboard is ergonomically Feature Description designed for left or right handed use. The buttons have Height 215 mm (8.46 in) clearly defined icons and colours to ensure ease of Width 78 mm (3.07 in) understanding and use. A large linen clip‐on cable ensures Depth 30 mm (1.18 in) that the handset does not slip off the bed Weight 420 g (14.8 oz) Handset‐removal alarm ensures that the handset is not Housing Plastic case inadvertently unplugged. The inline cord saver allows the Backlight All buttons handset to disconnect easily without damaging wall Nurse Call large button Brail ‘N’, connectors, monitors, or pendants. Nurse Assist 4 buttons Five Nurse Call Functions Environment 4 buttons (lights, blinds) Intercom Integrated The handset has five different Nurse Call icons which include Microphone/Speaker patient call, pain assistance, cleaning required, drink TV/Entertainment Depending on model requested and toilet assistance. These requests are routed as TV on/off., channel, volume. specific messages to the right care staff so the nurses and Connectors Breakaway 8 pin DIN plug, staff knows exactly what help the patient requires before breakaway 8 pin to USB A they visit a room. type. Improved Infection Control Cable 2 m (6.56 ft) of 8‐core multi‐ strand, double insulated The handset’s smooth shape allows for quick and easy Temperature Range white PVC cable cleaning and helps to prevent contaminants from collecting 0–50°C (32–122°F) on the unit. The handset is manufactured to be dip Humidity Range 0–85% Non‐condensing sterilisable and incorporates antimicrobial materials for increased infection control. It includes an Ingress Protection Rating of IP54 as defined by 60529 standard. Environmental Room Control Four environmental control buttons allow the patient to self‐ select the room environment without calling for a nurse. They can control room lights and a bed reading lamp, as well Compliance as buttons to control electronic window blinds. Designed to comply with: TV/Entertainment Controls • AS 3811:1998 Hard‐wired patient alarm systems for hospitals. The TV and Entertainment controls allow patients to control the entertainment simply, without need for other remotes. • AS 2999:1989 Alarm systems for the elderly and other TV sound is delivered to the handset speaker allowing for persons at risk. reduced sound level in the room. Patients are able to adjust sound level and mute for comfort. TV control is provided • HTM 08‐03: Bedhead services. from a Patient Station as either Infrared or Ethernet • UL 1069 Hospital Signaling and Nurse Call Equipment. messaged. • C‐Tick Electromagnetic compatibility. • IEC 60601‐1, UL 60601‐1 and CAN/CSA C22.2 No. 601.1‐ M90: Medical electrical equipment ‐ Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. Product Codes Description Order Options IP‐EMH/xx/yy/DIN8 Entertainment Multifunction Handset xx = Button colour: GR (Green), OR (Orange), RD (Red) (Product Family: Tacera) yy = Entertainment features: ENT (full), TV (TV with digits), TVB (Basic TV features) Terms & Conditions: For specific terms and conditions related to this product and other company products, please refer to the company website www.austco.com 2015‐12‐14
IP‐ODL‐4RGB – Over Door Light 4 segments, auto matically maximizes segment display for one to four call levels Features Ultra high visibility with wide 180˚ viewing angle Steady or flashing illumination Fail safe operation High reliability with long life LEDs IP Over Door Light The IP Over Door Light is used to indicate active alarms/calls using four segments. The colors and flash rates are uniquely programmable for each call priority, allowing any existing Nurse Configure colors to Nurse Call protocols to be simulated. Call Standard Code Alerts The IP Over Door Lights have been engineered to operate independently of the primary Nurse Call Floor Controller ensuring fail‐safe operation. Lower ‘Whole‐of‐Life’ Costs With the use of highly reliable LED technology, Over Door Lights do not require incandescent lamp replacement. Each light has a unique address and is supplied configured for immediate use. Once connected, the light is quickly and easily assigned to a room using a browser, which simplifies the process and reduces the cost of installation and commissioning. Tacera continuously checks the functionality of each light and will immediately notify maintenance staff if any problem is detected. The Over Door Lights are hot‐swappable, making maintenance a breeze – simply replace a light and then use a browser to quickly re‐assign functionality to the new light. www.austco.com
IP‐ODL‐4RGB – Over Door Light Information Easily Viewed from a Distance Technical Specifications There are red, green and blue LEDs in each segment that Feature Description provide improved reliability and increased brightness to Height 115 mm (4.53 in) (Australian ensure alerts are easy to view from a distance of up to 15 m Plate) and from either side. Width 145 mm (5.71 in) (Australian Depth Plate) Easy to Program On‐site 55 mm (2.17 in) (Standard) For each call priority, the colors and flashing rate of the Over Weight 110 g (3.9 oz) Door Light can be programmed on‐site using a browser. These Mounting Method Wall Box or Surface Mount parameters can be set as a specific standard for a ward, Housing (options) individual rooms or as a global standard for the site. Connectors Shatterproof, heat‐resistant Optional RGB Coloured Segments polycarbonate plastic dome 2 x RJ45 IPnet ports Four segments each have red, green, and blue LEDs allowing Cable Cat5/6 for a wide range of colors to be displayed to comply with Color Options 9 different color outputs in four Nurse Call Standard code alerts. Each segment can segments independently show a color or all segments can show the Temperature Range 0–50˚C (32–122˚F) same color. The available colors are shown in this table: Humidity Range 0–85% Non‐condensing Compliance Designed to comply with: • AS 3811:1998 Hard‐wired patient alarm systems for hospitals. • AS 2999:1989 Alarm systems for the elderly and other persons at risk. • HTM 08‐03: Bedhead services. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C‐Tick Electromagnetic compatibility. • IEC 60601‐1, UL 60601‐1 and CAN/CSA C22.2 No. 601.1‐ M90: Medical electrical equipment ‐ Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. Product Codes Description Order Options IP‐ODL‐4RGB IP Over Door Light, four segments (Product Family: Tacera) Terms & Conditions: For specific terms and conditions related to this product and other company products, please refer to the company website www.austco.com 2015‐10‐30
IP‐PSA – IP Power Supp ly Features Both outputs protected against overload External LEDs indicate operational status 110–240 V AC Input Battery backup in case of power failure Two individually switch ed power outputs Key switch protection IP Power Supply The IP‐PSA is a wall‐ or rack‐mounted 24 V DC battery‐backed power supply that is compatible with the Tacera Nurse Call System. It operates on 110–240 V AC input via a fuse‐protected mains input socket and cable. The IP Power Supply is small in size, allowing it to be installed in the communications room with minimal footprint. LEDs on the front panel of the power supply display operational status. IP‐PSA‐24V/R (front) Electronic fuses protect the power supply and automatically reset when the overload is removed. The IP Power Supply provides two 24 V DC power outputs, each capable of 4 A continuous power to a total output of 8 A. UPS Battery Backup The IP Power Supply incorporates a 24 V battery backup and External LEDs indic ate operational status charging circuit with two internal, sealed lead gel batteries rated at 7 Ah (the standard batteries are not included and should be ordered locally). Safe and Reliable The on/off switches for the DC power outputs are key‐switch protected to prevent inadvertent or malicious changes in settings. Both outputs are protected against overload by a fuse that automatically resets after the overload is removed. IP‐PSA‐24V/R (rear) www.austco.com
IP‐PSA – IP Power Supply Alarms and Indicators Technical Specifications External alarm outputs are provided for mains and/or DC Feature Description output failures. There is cabling to allow external plug‐in screw connectors to be conveniently accessed and a safety Height 430 mm (16.93 in) earth output is provided. Width 200 mm (7.87 in) Each of the two DC outputs has an ON/OFF push button which switches the appropriate output ON or OFF. Above Depth 130 mm (5.12 in) each switch are two green indicator LEDs. The top one indicates whether the OUTPUT is OK or not. This LED will Weight (2 m cable) 2.6 kg (5.73 lb) turn off if the output fuse has tripped. The second LED shows whether the output relay is switched ON or OFF. Mounting Method Supplied in 19” rack mount format but is site changeable to The BATTERY OK LED is green when the battery is fully wall mount by reversing rack charged and the output voltage is above 26 Volts. When wings. running on batteries, this LED will go off when the battery voltage becomes less than 22 V, which indicates the Housing 1.2 mm (0.05 in) thick powder‐ batteries are getting dangerously low. It will reilluminate coated steel when the mains power is restored and the battery voltage exceed 26 V. The LED may stay off when a battery is faulty Current 2 x 4 amp outputs and not charging properly. Voltage Input: 110–240 V AC 60/60 Hz The MAINS/FAN FAIL red indicator LED comes on when the incoming AC supply or the fan fails. At the same time, the Input Fuse 5 A 250 V corresponding ALARM OUTPUT is activated. Alarms Mains fail The OUTPUT LOCKED green LED comes on when the key Output fail <19.5 V switch has been locked. Batteries (not Lead acid gel The OUTPUT FAIL red indicator LED comes on, together with included) the corresponding ALARM OUTPUT, when either of the DC outputs is below 19.5 Volts. This is usually because the fuse Low Voltage <18 V has tripped, or the system is running on batteries and they Disconnect are getting low. Connectors Plug‐in screw terminals The output connectors will be completely disconnected from the power source when running on batteries and the Cable Length 2 core 2 mm2 TPS (AWG 14) battery voltage becomes less than 18 V. This is to protect Temperature Range power cable for each power the electronics from not operating correctly and to protect feed the batteries from deep discharge potentially destroying 0–50˚C (32–122˚F) the battery, reducing its ability to be recharged or shortening its life. When AC mains supply is restored the Humidity Range 0–85% Non‐condensing outputs will automatically be reconnected. Compliance Designed to comply with: • AS 3811:1998 Hard‐wired patient alarm systems for hospitals. • AS 2999:1989 Alarm systems for the elderly and other persons at risk. • HTM 08‐03: Bedhead services. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C‐Tick Electromagnetic compatibility. • IEC 60601‐1, UL 60601‐1 and CAN/CSA C22.2 No. 601.1‐ M90: Medical electrical equipment ‐ Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. Product Codes Description Order Options IP‐PSA‐24V/R IP Power Supply, 24 V (240 V AC Input) Wall mount delete /R IP‐PSA‐10/110/950 IP Power Supply, 24 V (110 V AC Input) Note: Battery is a standard 7 Ah lead gel, we recommend (Product Family: Tacera) local purchase Terms & Conditions: For specific terms and conditions related to this product and other company products, please refer to the company website www.austco.com 2015‐10‐26
IP-PST2 Patient StationSleek Design, Powerful FunctionalityFeatures and Benefits Highly ConfigurableDescription The IP-PST2 is configurable for use as either a single or double bed station. Comprising of a single module with four buttons, nine statusThe Tacera Patient Station (IP-PST2) is a wall or LED’s, two standard ¼” jacks and two 8 pin DIN sockets the IP-PST2 canbedhead unit that provides a complete in‐room be easily configured for use with standard call cords, pillow speakers, andpatient call and audio solution. Multiple external alarm devices such as infusion pumps or a combination of allpatient/resident handset sockets allow the three.patient station to support one or two beds perroom. The device serves as an IPnet Room Easy to Identify and UseController supporting all current IPnet devicetypes. Call activation is performed by pressing one or more of the three call buttons (labelled with its function). Additional room or ensuite speech orThe IP-PST2 is also compatible with digital non-speech call points can be connected directly to the Patient Stationpendants, including Austco’s Entertainment via its 2 IPnet patient area network ports.Multifunction Handset (IP‐EMH) which offers asophisticated television patient entertainment Features and Aestheticssystem interface along with up to four nurseassistance buttons and up to four environment The call buttons feature “soft touch” operation and are manufactured withbuttons for lights, fans, blinds, or air an anti-bacterial additive as an infection control measure. Backlighting ofconditioners. the call buttons provides for easy location and operation at night. An audible tone sounder and visual reassurance LEDs is standard.Highlights The IP-PST2 is designed to meet the requirements of any modern • Full Duplex VoIP for 2-way speech - healthcare facility with features such as “Clean Improves patient/resident and staff Mode”, “Cord Out” notification on sockets communication. without the need for dummy plugs, automatic “Entertainment Muting”, and built-in “Bed • Simplified cabling - Cabling and Interface” functionality. Its slim, unobtrusive infrastructure is reduced to only structural style and design with soft curves ensures cabling and a PoE switch. maximum patient safety while maintaining Austco’s unique style. • 3 configurable alarm buttons - Provides flexibility for different call types. • A single patient station – can be used for single or double bed rooms providing a complete in-room communication solution. Availability October 20, 2017 www.austco.com L-234, Rev. A
Technical SpecificationsFeature DescriptionHeight 118 mmWidth 176 mmDepth 28 mmWeight 470 gramsMounting Method Wall BoxWall Box Size Australian or North American Single or Double GangTemperature 0°C <---> 50°CHumidity Range 0% <--> 85% Non-CondensingConnectors Two DIN8 connectors Three RJ45 sockets: two Callpoint (IPnet), one Ethernet/PoE+ One 4-pin Communication port Two RJ9 for AM-TVCV One 2-position screw terminals for additional +24V power if required Two 3-pin Header for RLY Two 6.35mm (0.25-inch) pendant connectorsCable Sizes Power: Two-wire 2mm² (American Wire Gauge 14 (AWG14) max RLY: One 3 x 7/0.16 mm multi-core cable (optional RLY-Cord cable)Current Callpoint Controller: Two pairs of CAT5/CAT6Consumption AM-TVC: Four-wire modular 7/0.16 mm EMH: 2m (6.56 ft), 8-core multi-strand, double-insulated white PVC Pendant: 2m (6.56 ft), three-core multi-strand, double-insulated white PVC with large smooth plastic linen clip Standby: 60 mA During Intercom call: 225 mA (does not include consumption of connected devices)Voltage Power over Ethernet (PoE+) or 24 Volt DCComplianceNote: This product is manufactured in general accordance with the requirements of international quality assurance standard ISO-9002.Designed to comply with:• AS 3811:1998 (Hard-wired patient alarm systems for hospitals)• AS 2999:1989 (Alarm systems for the elderly and other persons at risk)• AS/NZS 4251.1 (Electromagnetic compatibility (EMC) - Generic emission standard - Residential, commercial and light industry)• AS/NZS CISPR22:2009 (Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement)• CAN/CSA C22.2 No. 205-17 3rd Edition• CAN/CSA C22.2 No. 601.1-M90 (Medical electrical equipment - Part 1: General requirements for safety)• CE Mark of European Conformity• HTM 08-03 (Bedhead services)• RoHS (Restriction of Hazardous Substances)• UL 1069 (Safety for Hospital Signalling and Nurse Call Equipment)• UL 60950 (Information Technology Equipment)• UL 60950-1 (Information Technology Equipment – Safety: Part 1 General Requirements)Ordering InformationFor further information, go to www.austco.com to contact an Austco representative near you. Product Code Description Order OptionsIP-PST2 VoIP Patient Station Insert Buttons are ordered separately. www.austco.com L-234, Rev. A
IP‐RLY – IP Dual Rela y Features Provides two individually controlled relays Electrically isolated for high voltage Patient may use hand held pendant for room and bed lighting and blind control Easy to install with silent operation Two individually con trolled relays IP Dual Relay The IP Dual Relay allows patients to control lighting and blinds from the comfort of their bed using any of Austco’s entertainment handsets or pendants. For maximum flexibility, the Dual Relay can be used to switch any connected device from any callpoint on the system. An integrated buzzer sounds when the Dual Relay is connected to a Room Controller, giving the installer reassurance that the device is has been detected and is functioning. Change‐over contacts allow each relay contact to be wired in a two‐way lighting circuit. Lower “Whole‐of‐Life” Costs The Dual Relay is IP‐based and features plug‐and‐play functionality. Dual Relays are typically installed in the patient’s room and connected in series using only standard Connects to the Roo m Controller Cat5/6 cable that also provides POIPnet (Power Over IPnet). Each Dual Relay has a unique address that is used to identify the device on the Room Controller Interface. Once connected, the device is quickly and easily assigned to an input or lighting control on a patient handset using a browser, which simplifies the process and reduces the cost of installation and commissioning. The system continuously checks the functionality of each Dual Relay and immediately notifies maintenance staff if any problem is detected. Dual Relays are hot swappable, making maintenance a breeze – simply replace a Dual Relay and then use a browser to configure the device. Individual Control There are two sets of relay contacts that are individually controlled from callpoint or pendant buttons via the Room Controller. The relays are designed for inductive or resistive AC loads up to 250 volts at 8 amps. Additionally, the relay outputs may be programmed for either continuous operation such as opening and closing blinds or for toggle based operations such as turning lights on and off. www.austco.com
IP‐RLY – IP Dual Relay Technical Specifications Safe and Reliable Feature Description The Dual Relay has been designed and manufactured to Height 95 mm (3.74 in) meet stringent international electrical isolation standards. The Dual Relay enclosure includes two cable‐clamp glands Width 135 mm (5.31 in) while the mains connectors are internal to allow safe termination of the lighting cables. Depth 36 mm (1.42 in) The electronic design allows POIPnet, removing the need for a separate power supply normally associated with a Weight 130 g (4.59 oz) mechanical pulse relay. As a result, the Dual Relay is both reliable and quiet. Mounting Method Surface mount Housing Plastic molding Connectors IPnet ‐ 2 x RJ45 socket Relay ‐ 2 x 3‐way screw terminal Cable Cat5 or Cat6 Power IPnet Voltage 24–32 V DC Isolation 1000 V Load 250 V AC 8 Amps Relays 2 Temperature Range 0–50˚C (32–122˚F) Humidity Range 0–85% Non‐condensing Compliance Designed to comply with: • AS 3811:1998 Hard‐wired patient alarm systems for hospitals. • AS 2999:1989 Alarm systems for the elderly and other persons at risk. • HTM 08‐03: Bedhead services. • UL 1069 Hospital Signaling and Nurse Call Equipment. • C‐Tick Electromagnetic compatibility. • IEC 60601‐1, UL 60601‐1 and CAN/CSA C22.2 No. 601.1‐ M90: Medical electrical equipment ‐ Part 1: General requirements for safety. • CE Mark of European Conformity. Manufactured in general accordance with the requirements of international quality assurance standard ISO9002. Product Codes Description Order Options IP‐RLY IP Dual Relay (Product Family: Tacera) Terms & Conditions: For specific terms and conditions related to this product and other company products, please refer to the company website www.austco.com 2015‐10‐26
TOUCH SCREEN NURSE STATION IP-TSNS/M-18/NA (NON-AUDIO)• Ultra-slim design for healthcare applications• True flat touch screen for easy cleaning• High performance with low power consumption• Fanless design for quiet operationInnovative, Sleek DesignThe IP-TSNS/M-18/NA Nurse Station features a 43mm thinbody enclosure, USB 3.0, and dual isolated Ethernet, whichlets hospitals separate and manage internal and externalnetwork traffic. The IP-TSNS/M-18/NA Nurse Station is idealfor applications in hospitals, long-term care facilities, andtreatment centers.The IP-TSNS/M-18/NA is used for installations withoutnurse call intercoms. Audible tones will sound for thehighest priority alarm in the Tacera alarm list.Dimensions 295 mm 475 mm 43.5 mmwww.austco.com IP-TSNS/M-18/NA, Revision A
Natural Viewing Experiencewith 16:9 18.5\" DisplaySPECIFICATIONS Intel® BayTrail Celeron® J1900 2.0 GHz (Quad-Core) CPU Basic Frequency 2MB 4GB (1 x SO-DIMM DDR3L 1333 MHz up to 8 GB) L2 Cache 1 x 2.5 internal SATA HDD bay Memory 2 x Gigabit Ethernet ports (RJ-45) HDD 1 x RS-232 Network 1 x RS-232 / 422 / 485 5 x USB 2.0 / 1 x USB 3.0Processor System I/O Ports 2 x Gigabit Ethernet (RJ-45) 1 x HDMIOS Support Stereo Speaker Audio Line-out x 1, Mic-in x 1Environmental BUS Expansion 1W x 2Specifications Mounting Full-size MiniPCIe/mSATA Dimension (W x H x D) VESA 100 x 100Power Supply Weight 475 x 295 x 43.5 mm 5 kgLCD Display Operating Temperature Win 10 IoT Enterprise Relative Humidity 0 ~ 40° C (32 ~ 104° F)Touch Screen Vibration 10 ~ 95% @ 40° C non-condensing Shock 0.5G EMC and Safety Certifications 10 G peak acceleration (11 msec. duration) Front Panel Protection CE, FCC, UL, CCC CB,BSMI Input Rating IP65/ NEMA4 Compliant 12 V/7 A (84W ITE Adapter) Power Consumption *12-30V Optional Typical 32W Size Max. 70W Max Resolution Max Color 18.5\" TFT LCD Pixel Pitch (um) 1366 x 768 (FHD 1920 x 1080 Optional) Brightness (cd/m2) View Angle 16.7M 300(H) x 300(V) Type 250 (Typical) Light Transmission 170°/160° Controller Analog Resistive 5-wires (Res. Flat Glass) / Projected Capacitive Touch Panel (Pcap. Flat Glass) / Glass Panel Res. Touch : 80% ± 5% / P-Cap Touch : 90% ± 2% COM interface / USB interfaceORDERING INFORMATIONProduct Code Description Order OptionsIP-TSNS/M-18/NA Touch Screen Nurse Station (non-audio voice call) N/AIP-TSNS/M-18 Desk Stand Desk Stand for 18” Touch Screen Nurse Station N/AIP-POWERCORD-T/M-EURO Power Cord specific for Europe Union (EU), non-UK countries 1.83 M for ITE N/AIP-POWERCORD-T/M-UK Power Cord specific for United Kingdom 1.83 M for ITE N/AIP-POWERCORD-T/M-AUS/NZ Power Cord specific for Australia/New Zealand N/AIP-POWERCORD-T/M-USA Power Cord specific for United States of America 1.83 M for ITE N/A(bundled with TSNS; purchase only for spares)© 2018 Austco Communications Systems PTY Ltd.All rights are reserved.Austco Communications Systems PTY Ltd. reserves the right to take changes in specifications and/or discontinue any product at any time without notice orobligation and will not be liable for any consequences resulting from the use of this publication. www.austco.com
Helping you keep a PULSE on your business PULSE Mobile Your alarms, on your phone, when and where you need them.What is Pulse Mobile?Pulse Mobile is a component of Austco’s Pulse platform and allows healthcare personnel to receive critical nurse call alarmnotifications directly on their smartphones. Pulse Mobile ensures that the right alarms are sent to the right caregiver,at the right time.Alarm PrioritizationPulse Mobile automatically prioritizes active nurse call alarms,placing the highest priority alarm at the top of the alarm list.This ensures that caregivers respond quickly to the highestpriority alarms.Call Back FeaturePulse Mobile provides touch-to-call functionality allowing caregiversto initiate a voice call from their smartphone directly to the locationwhere the alarm was activated. This enhanced communicationhelps caregivers better prioritize their workflow and assist withmanaging responses to various patient/resident alarms.
PULSE MobileDownload and Go Alarm Active Alarm Location DurationPulse Mobile is conveniently available for download in the Color CodedApple and Google play stores. Simply connect to your Alarm Typesfacility’s Wi-Fi network, allowing the mobile app tocommunicate with the Austco Integration Server software. Comprehensive & robust reporting: Customizable reporting of all facility alarms and responses toIMPROVE PATIENT critical events.OUTCOMES Intuitive User Interface: Extremely easy to learn and navigate using technology that staff are already If you are connected to Wi-Fi using Austco’s Integration familiar with. Server, Pulse Mobile will automatically be configured and updated. All that users need to do is log in with a valid Safe and Secure: Smartphones are used on the username and password. facility’s reliable Wi-Fi network providing consistent and secure communication. At no time is patient When a user logs in, they will begin to receive all active information stored on a recipient’s smartphone, alarms that are assigned to them. which ensures regulatory compliance. Pulse Mobile sends active alarms using push notifications to Easy installation and application updates: Pulse alert caregivers that an alarm has occurred. Mobile is conveniently available for download from the Apple and Google Play stores.Benefits Enhances staff mobility: Gives caregivers access to nurse call event data which eliminates the need to walk back and forth to the nurses' station. Increases staff efficiency: Routing nurse call alarms directly through smartphones allows staff to determine which alarms require immediate attention at a quick glance. Enhances established workflows: Ensures the right alarms are sent to the right caregiver at the right time. Increases patient satisfaction: Faster response times and reduced audible alarms create a quieter healing environments and provide a better overall patient experience. USA LATIN AMERICA CANADA9155 Sterling Street, Suite 100 2010 Rossmore Court 60 Granton Drive, Unit 6 Richmond Hill, Ontario, L4B 2N6 Irving, TX 75063 New Smyrna BeachUNITED STATES OF AMERICA FLORIDA CANADA 905-731-1830 +972-929-0974 407-574-7234 [email protected] [email protected] [email protected] L-213 www.austco.com
Achieve your facility goals with Ease and Simplicity Reports and DashboardsNurse Call Performance PortalTacera Pulse is part of a suite of software applications for personal computers or mobile devices that delivers business intelligenceinformation to an interactive dashboard, allowing you to make data driven decisions using current data from your organization.Reports With the urgent need to identify methods for validating nurse workload, productivity, and system effectiveness, facility managers and administrators now have a solution that tracks and manages critical caregiver-to-patient interactions and events. Tacera Pulse monitors nurse call alarms, collects alarm and response data, then creates metrics for measuring and analyzing performance outcomes. Facility and workflow data is now routinely captured and easily accessible. Tacera Pulse Reports gives decision makers the information they need to make informed decisions that optimize operations. Streamlining complex processes; such as scheduling staff, managing housekeeping, and overseeing maintenance creates more time to focus on high-quality patient care.Dashboards Dashboards provide a visual presentation of your facility’s KPIs (Key Performance Indicators), which allows you to effortlessly monitor many areas of operational performance simultaneously. Tacera Pulse dashboards are highly configurable and allow users to set preferences in terms of how their dashboards display and are organized.
SIMPLE TO USE AND LEARNLooks great, functions even better. Technology Tacera Pulse is a web-based KPI portal that uses modern web technology to create an intuitive, interactive desktop experience. Its responsive design allows the application to run on a desktop browser, tablet, or smartphone. A cloud based or hybrid installation reduces or eliminates the need to purchase and maintain server hardware and software.User-Friendly Graphical InterfaceTacera Pulse comes with an easy-to-use interface developed withinput from healthcare professionals. Accomplish your facility goalswith minimal training and administrative costs, thanks to TaceraPulse’s intuitive navigation and interactions.Use a mouse or a touch-enabled device to efficiently monitor andreport on the state of your facility.
DELIVER HIGH QUALITY CAREImprove Operational EfficienciesComprehensive and Robust ReportingThe healthcare industry is both competitive and highly regulated. Healthcare facilitiesare required to report on quality and capture key metrics necessary to validate theirability to provide a safe and efficient patient environment.Using Tacera Pulse’s enterprise level Reporting module, healthcarefacilities can aggregate data on specific KPI’s (key performanceindicators), giving facilities the ability to measure data with thegranularity needed to achieve facility goals which is essential toauditing performance and improving patient workflow. Personalized Dashboards Tacera Pulse’s personalized Dashboards provide hospital staff the ability to monitor call activity, staff response and other KPIs through an interactive dashboard. In addition, facility management and administrators can generate several types of reports, capturing metrics and information critical to validating nurse workload, increasing productivity and system effectiveness, and ultimately increasing the quality of patient care.
Search