EVAMATRIX Full Digital Network Voice Alarm and Public Address System EN 54-16 DanteTM Always around you compliance SPOKEN HERE
Stable, High performance, Secure … EVAMATRIX Is your system decentralized? Does your system cover many areas? EVAMATRIX guarantees that a freely configured installation will last long. NETWORK Main controller EVAMATRIX
Our mission is to provide you with the best technology. EVAMATRIX is an intelligent and reliable system for voice alarm, BGM and paging by fully integrated network with DANTE Matrix. EVAMATRIX is an inexpensive, compact system that represents the most innovative technology in Voice Alarm and Public Address. EVAMATRIX complies with the strictest European standards (EN54-16) for fire alarm systems. Remote MIC Fireman Remote MIC RM-VA1000 RM-VA1000 EN 54-16 compliance DanteTM SPOKEN HERE Digital Network Amplifier DPN Series
Up to standard EN 54-16 DanteTM ENcompliance DanteSPOKEN HERE compliance TM 54-16 EVAMATRIX system complies with European and other International standards. Full IP network system covers local area network via Dante protocol. Convenient and scalable system configuration Each system can cover 512 alarm zones, 1024 broadcasting zones and 2048 speaker lines.
Continuous control of the whole system Highly advanced and reliable voice alarm and public address system in a box. It will save you the cost of installation by combining the two systems in a single application. VA(Alarm, Alert) PA(BGM, Paging) Sequential emergency broadcast Two different VA messages of Alarm and Alert can be played simultaneously to different zones and changed from PA automatically by contact of emergency signal. On each alarm zone, it is possible to configure a delay (variable duration) and a pre-alert mechanism with the evacuation.
Digital network method Remote integrated control Centralized configuration support continuous control of the whole system and broadcasting on the network between multiple buildings and locations. Remote integrated control configuration Amplifier fault detection You can assign a channel to DPN amplifier to a channel from a separate amplifier as a backup channel. As soon as an amplifier fault is detected, the system will reassign the faulty channel automatically. The EVAMATRIX notifies the amplifier's fault by LED and buzzer to maintain the system.
Real time monitoring EVAMATRIX supports real time monitoring for any interruption in a transmission between speakers, any fire alarm devices, and the power supply at any location • Indicates Short circuit or interruption between transmission path and power supply • Indicates defect in the power supply to EN 54-4 • A sign of an earth flaw less than 50 kΩ that influences necessary features. • Any short circuit or interruption, at least common to all transmission path between parts of the VACIE, loudspeakers, any fire alarm devices • Power amplifiers fault • Indicates faults related to the transmission path to the CIE and the voice alarm zones
Detailed system monitoring System can be easily managed and configured by the 5” color LCD touch screen on main controller. •MAIN: CONFIGURATION, PA, VA, MP3 •CONFIGURATION : LANGUAGE, NETWORK SETUP, SYSTEM INFO, DATE/HOUR •PA : SOURCE VOLUME, SELECT SOURCES OF ZONE, RELEASE ROUTE OF ZONE, ZONE VOLUME, PRESET •VA : RESET, ALARM ROUTE/PLAY , ALARM RELEASE ROUTE/ STOP, ALERT ROUTE/PLAY, EMERGENCY LOG, TEST •MP3 : MP3 PLAYER Flawless security measure EVAMATRIX system provides a safe user environment by ensuring protection and security against hacking. In addition, access accounts have four levels to minimize any confusion to consumers using the announcements and to ensure reliable maintenance due to indiscriminate settings changes. Data exchange is highly secure by 256-bit encryption for maximum security. Level 1. Level 2. Level 3. Level 4. 256bit Security Admin Access Key Guest User Setup Operation Operation Maintenance Operation Operation Setting Maintenance Maintenance User preferences Setting
User-friendly, ergonomic, remotely operated solution The one and only system provides Bird Eye View, Annual Time Schedule and TTS as a standard feature. EVA can be adapted to any type of application without adding the extra units. Annual Scheduler TTS Text To Speech Annual SBcirhdeEdyuelVeriew TTS Text To Speech BirdEye View
System diagram Model Description Remark • 5\" touch screen EVAMATRIX 20 input * 8 output Main controller • Built-in GUI • PA/VA message DPN-240S 240W 1CH Network Amplifier DPN-240D 240W 2CH Network Amplifier • Speaker Line checker DPN-240Q 240W 4CH Network Amplifier • A/B speaker out per each channel DPN-480S 480W 1CH Network Amplifier • Support spare amplifier backup function DPN-480D 480W 2CH Network Amplifier RM-VA-1000 Network Remote MIC Dante Network • Support Aux input, control volume NETWORK Main controller EVAMATRIX
Remote MIC RM-VA1000 Fireman Remote MIC RM-VA1000 EN 54-16 compliance DanteTM SPOKEN HERE Digital Network Amplifier DPN Series
Application Main controller EVAMATRIX Multi Source Player CD-6208 Stereo Tuner TU-6200 Fire Alarm Remote MIC Switch RM-VA1000 LAN(Dante/TCP/IP) Fireman Remote MIC Network RM-VA1000
Power amplifier Audio(MIC/Line) DPS-480D Audio(Low/High-Z) Network(UTP) Power amplifier Contact DPS-480D Speaker DanteTM 1CH Network Amplifier 1A DPN-240S 1A Speaker SPOKEN HERE 2A 2CH Network Amplifier 1A Zone#1 DanteTM DPN-240D 4A 1B SPOKEN HERE Zone#1 DanteTM 4CH Network Amplifier DPN-240Q 1B SPOKEN HERE Spare Amplifier Zone#2 DanteTM 1CH Network Amplifier DPN-240S 2B SPOKEN HERE Zone#1 1B Zone#4 4B Speaker
Application_Easy zone expansion ● Built-in 20 x 8 BUS Matrix Fire Alarm ● Dante™ network audio transmission ● Emergency system that can detect main signal errors and Switch communication line in advance Main control room 1A 1B 1Ch Amplifier Zone#1 Remote MIC (EVACUATION) ● Intuitive Web-based GUI ● EVAMATIRX system for control and monitoring Site#1 Zone#1 Switch Remote 1A MIC 1B 2Ch Amplifier 2A 2B Zone#2
Site#2 Audio(Low/High-Z) Network(UTP) 1A 1B Zone#1 2A 4Ch Amplifier 2B Switch Zone#2 3A 3B Zone#3 4A 4B Remote Zone#4 MIC ● TCP/IP based remote microphone ● PA (for paging) and VA mode (for fireman) ● Support up to 48 Units
20×8 Bus Matrix Controller EVAMATRIX ● Main server unit ● EM MIC (PTT MIC), Emergency messages ● Main unit redundancy ● MP3 player for BGM ● Network redundancy (All components) ● 8 CH Analog audio input/output ● Embedded DSP (All source devices) ● Contact In/Out EVAMATRIX Power Voltage 100-230VAC, 50-60Hz / 24VDC Frequency response 20Hz – 20kHz at -3dB THD <0.5% S/N ratio >85dB Audio specification AD/DA converters 48khz, 32bit – for DSP Function Inputs MIC / LINE (1 ~ 8, Euro 3pin) Switchable 0dBV 10㏀(LINE) / Outputs -60dBV 600Ω Balanced (MIC, w/Phantom Power 24VDC) PC Link Extension Link AUDIO OUT (1 ~ 8) 0dBV balanced Security Input MONITOR 0dBV balanced Synthesis default Output Output to other devices RJ45 connector, TCP/IP Protocol Operating Temperature Input and Output, RJ-45 connector(Dante), Relative Humidity Dimensions (W x H x D) Cat. 5 cable (Maximum distance: 100m) UGA Inputs 1 ~ 5: Triggered by voltage Dry Contact Inputs 1 to 8: Triggered by Dry Contact NO/NC Synthesis detect outputs SD 1 ~ 5: Relay Output Dry Contact Outputs (1 ~ 16): Relay Output -10℃ ~ +40℃ 5 ~ 95% RH 483 x 88 x 279 mm (19” rack 2U)
Front Panel ❹ ❸ ❶ ❷ ➊ LED INDICATORS ITEM COLOR DESCRIPTION POWER ON GRN Lights when power (both AC 230V or DC 24V) is normal SYSTEM OK GRN Lights at start-up when there is no fault in system SYNTHESIS FAULT YEL FAULT lights when there is an error in the system (Output to the relevant area with SYNTHESIS DEFAULT contact) ALARM RED Lights when ALARM mode is on, SYSTEM FAULT YEL Lights up when there is a fault in the system MESSAGE FAULT YEL (memory fault, processor fault, program monitoring fault) Lights when the EM player is not working or there is a falult on SD card ZONES DISABLED YEL Lights when some zone area is unavailable FUSE FAULT YEL FUSE FAULT YEL Lights when AC or DC FUSE is blown out Lights when AC or DC FUSE is blown out ➋ SD CARD SLOT ➌ 5\" COLOR LCD TOUCH SCREEN ➍ MONITORING SPEAKER Rear Panel ⓬ ⓭ ❿ ❶❷ ❺ ❸ ⓫ ❽ ❹ ❻❼ ❾ ➊ AC INPUT ➓ DRY CONTACT OUTPUT (1~12) ➋ AC FUSE HOLDER Notify the system in alarm mode. ➌ DC INPUT TERMINAL Configure setting on the configuration menu ➍ MIC/PAHNTOM MIC/LINE INPUT TERMINAL (1-8) ➎ AUDIO OUTPUT TERMINAL ⓫ TCP/IP NETWORK (10/100/1000) TERMINAL ➏ PTT MIC CONNECTION TERMINAL Network port to support redundancy TCP/IP ➐ SD CARD (MESSAGE 1, 2) Network for system control Dante network for A space for storing emergency messages audio transmission and consists of two slots ⓬ UGA / DRY CONTACT INPUT TERMINAL ➑ SYNTHESIS DETECT OUTPUT TERMINAL Allowed to send an alarm after receiving fire A terminal for informing the self-diagnosis result to an external device occurrence information ➒ REMOTE MIC ⓭ REMOTE MESSAGE TERMINAL (1~8) Connect to RM-VA1000 Read presets to contact input and send specific sound source file built in sd card to specific place
DPN series Network Digital Amplifier DPN-240S/D/Q DPN-480S/D ● 240W 1/2/4CH or 480W 1/2CH network amplifier for ● Log history management EVAMATRIX ● Compelte protection circuitry (overheat, output short ● High-quality audio network transmission via Dante™ circuit, overload and DC output protection) ● DSP processing for the audio ● Supports DC backup power ● Web-based network communication and monitoring ● Supports UGA input and dry contact input per each and control on GUI channel. ● Built in speaker line checker ● 1 Audio-in available per each device.
Front Panel ❶ ❺❻ ❼ ❷ ❸❹ ❽ ❾ ❿ ⓫ ➊ SIG / -10dB / CLIP / PRT ➐ POWER ON Indicate the amplifier input level by -30/-10/clip/protect Indicate that the power is ON (GREEN) ➋ DISABLED ➑ SYSTEM OK Indicate that the amplifier is DISABLED (YELLOW) Indicate that the system is normal (GREEN) ➌ AMP FAULT ➒ POWER FAULT Indicate that the amplifier is in FAULT (YELLOW) Indicate that the power is in FAULT (RED) ➍ LINE FAULT ➓ SYSTEM FAULT Indicate the speaker line FAULT status (YELLOW) Indicate that the system is in FAULT (RED) ➎ OLED DISPLAY ⓫ NETWORK FAULT The network status is displayed on OLED Display Indicate that the network is in FAULT (RED) ➏ DISPLAY CONTROL SWITCH Use the switch to control the OLED Display Rear Panel ❷ ❺ ❾ ❶ ❼ ❿ ❸ ❹ ❻❽ ➊ AC IN ➏ FAULT IN ➋ DC IN A contact closure input terminal to detect FAULT ➌ AMP OUTPUT Each channel has two output channels: A and B ➐ AUDIO IN External analog audio input ➍ SPARE IN A terminal to receive the output of the spare amplifier ➑ DRY CONTACT IN A contact closure input terminal for each channel ➎ NETWORK Network port to support redundancy TCP/IP Network ➒ UGA IN for system control Dante network for audio A UGA contact closure input terminal transmission ➓ DRY CONTACT OUT A contact closure output terminal for each channel
EVA System Remote MIC RM-VA1000 ● EVAMATRIX interface through the network ● 10/100/1000Mbps support ● A device to broadcast paging to each zone ● DC 24V adapter power input terminal ● Gooseneck Mic input ● Check the output signal in real time through a monitor ● All Zone On/Off selection ● Chime Mode selection speaker ● Emergency sound selection function ● Supports PA mode(for paging) and VA mode(for ● Audio transmission through Dante fireman) Front Panel(PA) Front Panel(Fireman) Rear Panel
EN 54-16 Voice alarm control and indicating equipment MANDATORY REQUIREMENTS ● Indicating Short circuit or interruption between transmission path and power supply ● Indicates defect in the power supply to EN 54-4 ● A sign of an earth flaw less than 50kΩ that influences necessary features. ● Any short circuit or interruption, at least common to all transmission path between parts of the VACIE, Loudspeakers, any fire alarm devices ● Power amplifiers fault ● Flaw of VA Zones » One fault indicated in VA zone ● Indicating connection flaw with VA system » additional indication necessary EVAMATRIX SPECIAL FUNCTIONS ● Redundant power amplifier ● Microphone for fireman ● Audible warning indication ● Phased evacuation ● Set the delay to voice alarm ● Manual mute of voice alarm ● Manual reset of voice alarm ● Output through fire alarm devices ● Output of voice alarm ● Manual control of voice alarm ● Indication of faults related to the transmission path to the CIE ● Indication of fault related to voice alarm zones ● Interface to the external control device ● Annual scheduler ● TTS (Text to Speech) ● Bird’s-eye view
NOTE
NOTE
EVAMATRIX Full Digital Network Public Address and Voice Alarm System Inter-M Corp. (IMK) 719, Dobong-ro, Dobong-gu, Seoul, Korea E-mail_ [email protected] www.inter-m.com Overseas Sales Team 2020. 6. V1 Tel_ +82-2-2289-8141~7 Fax_ +82-2-2289-8149 ※ Design and specification are subject to be changed for the improvement of product quality without pre notice.