["Normal Yes Heating mode is preferred. Select non-pre ferred mode (cooling) or operation *2 mode, which is different from selection way of switch setting. No The abnormity of Indoor unit Indoor unit PCB board is in bad condition; Wired controller is in bad condition. No *3 PCB board in wired controller is in bad condition; Yes Whether there Wires around the PCB board of indoor unit are broken is AC15V voltage and the insertion of socket is poor. between terminal blocks A and B of wired controller No Wrong connection between indoor unit and wired Whether there controller Yes is AC15V voltage between terminal blocks A and B of indoor unit The transformer of Indoor unit is in bad condition; Voltage The PCB board of Indoor unit is in bad condition. No No Whether there Whether the LED (green and red) on control Yes is AC220V voltage base board of the indoor unit is between terminal blocks L and N of indoor unit Yes No Voltage Check the power Whether the fuse of Yes supply wire of indoor The transformer of Indoor unit is in bad condition; Wires around the PCB board of indoor unit are broken indoor unit PCB board is unit and the insertion of socket is poor. normal No Find the cause of the fuse burnout 148","Start Set the operation to air supply mode, and press the operation switch. Whether there is air No Check the indoor unit fan, sent out of the outlet of fan motor and air blower indoor unit circuit Yes Whether there is No Check the surrounding abnormal sound condition of air blower No Normal Note: Check the indoor units one by one. 149","Start Check all indoor units one by one. Set the operation to cooling mode and hold Once stop, the outdoor down the operation switch for more than 5 unit can\u2019t restart until 3 seconds in shutdown mode. to 5 minutes later. Whether the cold air is blown out No operation condition of the No compressor Yes rotation direction of the blade Whether air circulation is in good condition Yes Make all the indoor units operate simultaneously Whether the temperature No difference between return air and supply No Check and the power supply air is proper (Note 1) voltage and circuit Yes No Check the temperature of indoor and outdoor; Whether the operating voltage is proper (380 V \u00b1 10%) Check pipe length and charging amount of the refrigerant; Yes Check operating frequency of the compressor Whether the operating current and operating condition of the outdoor fan; is at \u00b1 15% of the standard value (at No Check whether there is abnormal sound in the maximum frequency) (Note 2) compressor. Yes Whether operating pressure is normal (Note 3) Yes Normal 150","Start Check all indoor units one by one. Set the operation to heating mode and hold Once stop, the outdoor down the operation switch for more than 5 unit can't restart until 3 seconds in shutdown mode. to 5 minutes later. Whether the warm air is blown out No operation condition of the compressor Yes No rotation direction of the blade. Whether the air circulation is in good condition Yes 66 Make all indoor units operate simultaneously Whether the temperature No difference between return air and supply No Check and the power supply air is proper (Note 1) voltage and circuit Yes No Check the temperature of indoor and outdoor; Whether the operating voltage is proper (380 V \u00b1 10%) Check pipe length and charging amount of the refrigerant; Yes Check operating frequency of the compressor Whether the operating current and operating condition of the outdoor fan; is at \u00b1 15% of the standard value (at No Check whether there is abnormal sound in the maximum frequency) (Note 2) compressor. Yes Whether the operating pressure is normal (Note 3) Yes Normal 151","(Note 1)The general standard for temperature difference between inlet and outlet air In \\\"cooling\\\" operation, it is normal that the dry bulb temperature difference between inlet air and outlet air of the air conditioner is over 10\u00b0C (at the maximum frequency) after 30 minutes at least. In \\\"heating\\\" operation, it is normal that the dry bulb temperature difference between inlet air and outlet air of the air conditioner is over 14\u00b0C (at the maximum frequency) after 30 minutes at least. (Note 2) General standard for operating current It is normal that the current in either cooling\/heating operation mode is within \u00b115% of the calibrated current. The value of current may have the following differences due to different operation conditions: When higher than the standard value of the current: the temperature of indoor and outdoor is high; heat dissipation of outdoor unit is poor. When lower than the standard value of the current: the temperature of indoor and outdoor is low; (Note 3) General standard for operating pressure Cooling High pressure 2.0~3.8 MPa Indoor 18-32\u00b0C Outdoor 25- (at the maximum frequency) Low pressure 0.6~1.0 MPa 35\u00b0C High pressure 2.2~3.0 MPa Heating Low pressure 0.3~0.8 MPa Indoor 15-25\u00b0C Outdoor 5-10\u00b0C (at the maximum frequency) Values after 15-minute operation (the temperature therein refers to dry bulb temperature with unit of \u00b0C) The transformation trend of high pressure and low pressure due to change of operation condition Refrigeration\/heating: indoor temperature rises \u2013 high\/low pressure rises Indoor temperature drops \u2013 high\/low pressure drops Outdoor temperature rises \u2013 high\/low pressure rises Outdoor temperature drops \u2013 high\/low pressure drops Evaluating unit through test device Begin to operate the system whose complete setting has Operation Operating methods: 1. Switch the BM1, BM2 to OFF , search the indoor units and outdoor unit to check if the number of indoor units are right. 2. Switch the SW1, SW2, SW3 to 0, 13, 2 respectively, then press SW2 for 2 seconds, the digital display tube will display \u201c1111\u201d and indoor unit will enter into cooling operation; or switch SW1, SW2, SW3 to 0, 14, 2 respectively, then press SW2 for 2 seconds, the digital display tube will display \u201c1111\u201d, indoor unit will turn on automatically and enter into heating operation. Frequency of compressor is controlled by low pressure control for cooling, and high pressure control for heating. 152","1. Connecting methods of device: Position of inserting test device (CN47) Insert one end of data line into the terminal of main PCB CN31 with a two-core terminal, one end connects with 485 device or Gangda device, the other end of the device connects computer. 2. The data that can acquire through device Outdoor unit: The frequency of outdoor unit compressor \/Outdoor fan speed\/Opening of outdoor electronic expansion valve\/ High pressure of outdoor unit\/Corresponding saturation temperature of outdoor unit\u2019s high pressure\/Low pressure Data of outdoor unit\/Corresponding saturation temperature measuring of outdoor unit\u2019s low pressure\/Discharging temperature\/ Suction temperature\/Oil temperature\/ Temperature of condenser outlet pipe\/Ambient temperature\/Temperature of defrosting sensor\/Starting of all kinds of solenoid valve Indoor unit: Temperatures of gas pipe and liquid pipe, opening angle of electronic expansion valve \/Display of failure It is normal if there is high pressure frequency 3.Test device can display failures of the unit during data limitation or high discharging temperature operation, moreover it can realize a function of storing in real time, and the test data can be stored in computer. frequency limitation when outdoor ambient 4.Prepare a report according to the test data and submit it temperature is high and all the indoor units are to user. operating. of the data the measurement. After the measurement is begun, check the system pressure through detection software. Generally, the cooling low pressure is about 7.5kg and the heating high pressure is about 28kg under rated cooling and heating modes. Then observe if operation under each parameter is normal. There is a picture about cooling operating parameters\u2019 data in the right column, after operating about half hour, the unit remains stable. Check if there is a blockage in capillary during operation, if any, replace it. Check if there is contact between refrigerant piping and capillary tube, if any, deal with it. Check if wires of sensor (such as wiring, pressure sensor, etc.) are too tight, or contact with vibrating pipe, if so, deal with it. Check if the value of sensor is correct. 153","18. Startup 18.1 Startup procedure 1. The materials preparation before on-site commissioning --Printed drawing of architectural design --Printed installation checking list and system start request --Startup manual --MRV 5 service manual --Trouble shooting and error code 2. Read the attention carefully before start up 3. Installation checking --installation checking --Parameter standard checking list 4. Operation --Dip switch setting for indoor units --Dip switch setting for outdoor units --Dip switch setting for controllers --Power on --Locking quantity of indoor and outdoor units (BM1-1\/BM1-2) 5. Trail operation --Startup of indoor units --Running parameter checking --Running parameter standard --Completion of startup report 18.2 Installation checking 1. Piping --Branch pipe installed horizontal way --Branch pipe distance,1m (39.37 inch) away from each other and 0.5m (19.7 inch) far from IDU 2. Drain --1% gradient (indoor unit) --Exhaust outlet for drain pipe (indoor unit) --Aerial part height above 200mm (outdoor unit) 3. Communication wire (important) --PQ cable connected hand by hand --The PQ shielded layer must be single point ground to master unit --The PQ cable is 2X0.75mm with shielded layer --There is at least 10cm (3.94 inch) distance between communication and power source line --Before starting, don\u2019t connect the terminal PQ to the ODU, it may cause unexpected start 4. Electricity wire --Independent wire line to each IDU -- Same phase power supply -- Add breaker for each IDU -- Electricity wire installed to IDU and ODU correctly 154","5. Indoor unit --Anti-dust protection during installation --Installed on properly level --Service space reserved at least 50X50cm 6. Outdoor unit -- Installed an anti-vibration at the bottom -- Space (20cm\/7.87inch away from each other) -- Gather pipe are the same level -- Breaker -- Communication cable (A \/ B \/ C, PQ) 7. Pre start up -- 100% of the piping completed the pressure test -- Vacuum test -- The system have been with electric power more than 6h -- Outdoor unit addressing (Master 0, slave 1, slave2) -- Indoor units are addressing correctly -- All the indoor units work correctly in Fan mode 155","18.3 Wiring-dip switch 1. Indoor dip switch setting\u2014Indoor units for MRV5 and indoor units for MRV IV-C are the same, so indoor dip switch setting is completely the same, please check with the service manual. 2. Controller dip switch setting- it\u2019s the same as the controller dip switch setting of MRVIV, please check the service manual. IDU Dip switch setting For different IDU PCB board, the setting is little different. When start up, check the below Dip switch setting: SW01 (1~4 or 2~4)--------Set the master\/slave unit when use wired controller in group control SW01 (5~8)-----------------Set the capacity of the unit(default setting, no need to reset) SW03 (1~8)------------------Set the communication address and central address(the default setting is set the address by wired controller or automatically) ODU Dip switch setting BM-1 The engineer set on site BM-2 Dip switch BM-3 Pre-set in factory Check operating parameter & E2 control BM-4 SW1 SW2 SW3 156","18.4 Power on 1. For the protection of the compressor, It is required to preheat the compressor oil before start up the indoor and outdoor units. 6 hours of preheating is the standard time for the preheating, the engineers have to wait for 6 hours until the compressor oil reaches the required temp. The main PCB will show on the LED time counting down. 2. The outdoor and indoor units communication P, Q should be disconnected before turning on indoor units in case of any unexpected operation. 18.5 Search and lock outdoor \\\\ indoor unit 1. Search: Set BM1-1 at off to search outdoor unit, set BM1-2 at off to search indoor unit. 2. Lock: When ensuring that the displayed indoor units, valve boxes and outdoor units quantity is equal to that of actually installed, the indoor, valve box and outdoor units quantity can be locked. The locking method is to set the master module dip switch BM1-1 and BM1-2 from OFF to ON. 18.6 Trial operation and parameters record 1. The requirement of startup is to set the temp. to be 16 degree centigrade, high speed fan in cooling mode and 30 degree centigrade, high speed fan in heating mode. The following is the example when using wired controller of temp. display. 2. In cooling or in heating mode, let the outdoor and indoor units run for 1 hour; 4. Running Parameters Checking Standard. Mode TA Pd(MPa) Ps(MPa) Toil Td(\u00b0C) Ts Outdoor EEV Indoor EEV Cooling 18~27 1.5~2.4 0.4~0.85 closed to Td 60~110 28~35 1.7~3.2 0.5~0.9 closed to Td 60~110 -20~30\u00b0C 250 60~480 Heating above 35 2.0~2.9 0.7~1.05 closed to Td 60~110 below -5 1.6~2.8 0.1~0.4 closed to Td 60~110 -20~30\u00b0C 250 60~480 -5~7 1.9~2.8 0.3~0.8 closed to Td 60~110 above 7 2.2~3.6 0.8~1.05 closed to Td 60~110 -20~30\u00b0C 250 60~480 -20~30\u00b0C 60-350 200~480 -20~30\u00b0C 60-350 200~480 -20~30\u00b0C 60-350 200~480 157","18.7 MRV 5 system startup report MRV 5 INSTALATION CHECK LIST AND SYSTEM START UP REQUEST ENGLISH BETA 1.2 PROJECT: DATE: DD \/ MM \/ YY CUSTOMER: INSTALLER: CITY\/COUNTRY: ADDRESS: CONTACT TEL: SYSTEM 1 CODE PROJECT CONFIGURATION SYSTEM 2 CODE SYSTEM 3 CODE MODEL SYSTEM 4 CODE MODEL SYSTEM 5 CODE MODEL SYSTEM 6 CODE MODEL SYSTEM 7 CODE MODEL SYSTEM 8 CODE MODEL SYSTEM 9 CODE MODEL SYSTEM 10 CODE MODEL SYSTEM 11 CODE MODEL SYSTEM 12 CODE MODEL SYSTEM 13 CODE MODEL SYSTEM 14 CODE MODEL SYSTEM 15 CODE MODEL MODEL MODEL COMMENTS: INSTALLER: SIGNATURE: DATE : 158","MRV 5 INSTALATION CHECK LIST ENGLISH BETA 1.2 1. PREINSTALATION YES 1.1. REFRIGERATION PIPING * Refrigerant piping are correctly insulated. * All branch pipes are installed in horizontal direction. * There are at least the distance of 1m between branch and branch, and 0.5m far from the indoor units. 1.2. DRAIN * Drain piping is correctly insulated. * Exhaust outlet for drain pipe. * A drop of at least 1% is guaranteed (1 cm per linear meter). * Drain's piping diameter is according to requirements. * Drain piping is separated for unit with drain pump. 1.3. COMMUNICATION WIRE * The communication wire is properly installed between outdoor and indoor units - P\/Q (Assy. chain). * The wire for centralized control is properly installed between A\/C and interface (Assy. chain). * Sequence of colors in the cord is guaranteed P-P, Q-Q. * There is independent pipeline for communication wire. * There is a 10cm distance between communication wire and electricity wire at least. * Before starting, do not connect the terminal P, Q on the outdoor unit, it may cause unexpected start. 1.4. ELECTRICITY WIRE * There is independent pipeline for electricity wire to each indoor unit. * There is a general power supply for all indoor unit. * There is same phase power supply for all indoor units in one group under wired controller. * Security power off system: Is there a breaker for each outdoor and indoor unit? * Electricity wire is installed to indoor and outdoor units correctly. 1.5. INDOOR UNITS * During installation indoor units have dustproof protection. * Indoor units are in the perfect physical conditions, free of dents or dings. * There is at least 50 cm of free space around indoor unit for service and maintenance. 159","MRV 5 1.6. OUTDOOR UNITS * Is Installed an anti-vibration system for the outdoor units. * The ground where the outdoor units are must be properly leveled. * 1 meter of distance is guaranteed for the outdoor units of walls and others. * Outdoor units are in the perfect physical conditions, free of dents or dings. * The outdoor units in same system have 20cm distance to each other. * Gather pipe are at the same level. * Each outdoor unit have a security breaker. * A drain pan is required to the Outdoor unit (HEAT MODE). * The communication wire is properly done between the outdoor units A, B, C. * The communication wire is correctly done for the centralized monitor between master outdoor unit and interface (Assy. chain) * The balance oil pipeline is at the same level Without outlets and Piping trap. * Outdoor units are supported on anti-vibration system. 2. PRE START UP * 100% Of the piping completed the pressure test at 80 psi (5.5 Kg\/cm2) during 3 Minutes * 100% Of the piping completed the pressure test at 250 psi (17.5 Kg\/cm2) during 2 Hours * 100% Of the piping completed the pressure test at 590 psi (40.5 Kg\/cm2) during 24 Hours * Vacuum test, reaching gauge presssure of: (-755mmHg) * The system have been with Electric power more than 6 hours before de start up. * Indoor units are addressed properly. * Outdoor units are addressed according the position Master, Slave 1, Slave 2 y Slave 3. * Once the system is connected to electric power, the master outdoor unit display show the indoor units quantity connected. * All the Indoor units and vale boxes work correctly in Fan Mode. 160","SYSTEM START UP LIST MRV 5 ENGLISH BETA 1.2 SYSTEM CODE MODEL V * Refrigerant recharge calculation V V Liquid pipe size Multiple factor Length Subtotal 6.35 (1\/4\\\") 0.022 9.52 (3\/8\\\") 0.054 12.7 (1\/2\\\") 0.11 15.88 (3\/4\\\") 0.17 19.05 (5\/8\\\") 0.25 22.22 (7\/8\\\") 0.35 25.4 (1\\\") 0.52 Total(Kg) Outdoor unit No. Model Serial No. Master Slave1 Slave2 *Please input measured voltage values before start up: L1 vs. L2 V L1 vs. N V L1 vs. Ground L2 vs. L3 V L2 vs. N V L2 vs. Ground L3 vs. L1 L3 vs. Ground V L3 vs. N V 161","MRV 5 ENGLISH BETA 1.2 START UP * Do measurements with all units switched ON after 1 hour. No. Items SW9\/10\/11 Master SW9\/10\/11 SLAVE 1 SW9\/10\/11 SLAVE 2 1 Pressure Pd1 (bar) 0\/0\/1 1\/0\/1 2\/0\/1 3 Pressure Ps (bar) 0\/2\/1 1\/2\/1 2\/2\/1 4 Temp.Td1 (\u00b0C) 0\/3\/1 1\/3\/1 2\/3\/1 5 Temp.Td2 (\u00b0C) 0\/4\/1 1\/4\/1 2\/4\/1 8 Temp.Tdef1 (\u00b0C) 0\/5\/1 1\/5\/1 2\/5\/1 10 Temp.TA (\u00b0C) 0\/1\/15 1\/1\/15 2\/1\/15 11 Temp.Toil1 (\u00b0C) 0\/7\/1 1\/7\/1 2\/7\/1 12 Temp.Toil2 (\u00b0C) 0\/8\/1 1\/8\/1 2\/8\/1 13 Temp.Toci1 (\u00b0C) 0\/9\/1 1\/8\/1 2\/8\/1 15 Current CT of inverter 0\/10\/15 1\/10\/15 2\/10\/15 compressor INV1 16 Current CT of inverter 0\/11\/15 1\/11\/15 2\/11\/15 compressor INV2 1\/15\/1 2\/15\/1 17 Fixed Compress current 0\/15\/1 Current frequency of 18 inverter 0\/5\/0 1\/5\/0 2\/5\/0 compressor INV1 Current frequency of 19 inverter 0\/6\/0 1\/6\/0 2\/6\/0 compressor INV2 20 Outdoor unit QTY 0\/2\/2 21 Indoor unit QTY 0\/3\/2 22 Running indoor unit QTY 0\/4\/2 23 The end Indoor unit No. Model PMV TA TC1 TC2 Serial N\u00b0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 162","19. Outdoor control board photo BM1 PCB code: 0151800256 SW1 SW2 SW3 SMG2 SMG1 BM2 SW6 SW4 (STOP) (UP) BM3 SW5 LED1 (START) SW7 BM4 (DOWN) LED3 LED4 LED5 LED7 BUS-B STOP LED6 BUS-A 163","1 2 3 4 20 5 19 18 67 17 16 No. Function 15 1 Power connector 14 2 Solenoid valve connector 3 Low-power standby control connector 13 4 Compressor heating tape connector 12 5 High pressure switch connector 6 Outdoor EEV connector 8 9 10 11 7 Ambient temperature, coil temperature sensor 8 Indoor communicating connector No. Function 9 Monitoring computer connector 11 Emergency stop signal connector 10 Centralized control 485 communication connector 12 Monitoring PC WIFI connector 13 Power suppression signal connector 14 Expansion PCB 12VDC power supply connector 15 Zigbee wireless communication connector 16 Expansion PCB communication connector 17 Reserved password lock decryption connector 18 Reserved PM2.5 detection connector 19 Programming connector 20 Module board communicating connector 164","Compressor driver board: 0151800260 9 8 1 2 7 6 3 4 5 No. Function 1 Connected reactor connector 2 Low-power standby control connector 3 Connect electrolytic capacitor PCB connector 4 Module three-phase power input connector 5 Module drive output connector 6 Dip switch 7 Programming connector 8 Main PCB and fan motor communicating connector 9 15VDC power output connector 165","Filter board: 0150401866 1 2 3 No. Function 1 Filter board output connector 2 Filter board ground wire connector 3 Filter board power input connector 166","Capacitor board:0150401863 3 1 2 No. Function 1 Electrolytic capacitor negative connector 2 Fan DC power supply connector 3 Electrolytic capacitor positive connector 167","20. Outdoor PCB dip switch setting \u2022 LED1: power supply lamp Power on light \u2022 LED3: electronic expansion valve LEVa1, LEVa2, fault lamp No fault, not light \u2022 LED4: electronic expansion valve LEVb, LEVc, fault lamp No fault, not light \u2022 LED5: communication lamp between outdoors \u2022 LED6: communication lamp between indoor and outdoor \u2022 LED7: communication lamp between PCB and power module \u2022 Physical master unit: the outdoor unit, whose number is set as 0 by dip switch(BM1-7 and BM1-8), is the communication sponsor and in charge of the communication with indoor unit, also works as initiator of communication of the whole outdoor unit. \u2022 Function master unit: the outdoor unit, whose priority is set as 0, operates with the highest priority. \u2022 Physical slave unit: the outdoor unit, whose number is not set as 0 by dip switch(BM1-7 and BM1-8). \u2022 Function slave unit: the outdoor unit, whose priority is set as 1~3, not operates with the highest priority. \u2022 Setting of group class: the setting of physical master unit is valid for the whole unit. \u2022 Setting of local class: it is only valid for this unit, not for the whole unit. Dip switch introduction: \u2022 BM1 is usually set by the engineer on site; BM2, BM3, BM4 are pre-set in the factory. The quantity of total two outdoor units, \\\"3=012\\\" is three outdoor units, \\\"4=0123\\\" is four outdoor units. \u2022 BM1_2: Master outdoor unit searches the total indoor units after locked the quantity of the outdoor units. The \\\"-06-\\\" is 6 indoor units, \\\"-15-\\\" is 15 indoor units. \u2022 BM1_3: The setting is OFF or ON. Default is ON. Once power off, unit software shall reset to \\\"OFF\\\" automatically ignoring BM1_3 setting. 168","\u2460 BM1 introduction BM1_1 Outdoor searching OFF Begin to search outdoor BM1_2 after startup ON Stop searching outdoor and lock the quantity BM1_3 Indoor searching after startup OFF Begin to search indoor BM1_4 BM1_5 Start up condition selection ON Stop searching indoor and lock the quantity BM1-6 BM1_7 Outdoor mode setting Power on, no matter this dip switch is on \\\"ON\\\" or \\\"OFF\\\" BM1_8 Outdoor static pressure position (default is OFF) don't change the dip switch position, the unit will start after 6 hours preheat or within selection 6 hours when oil temp. meets the standard value: Communication protocol If you want to reduce the startup condition, you can do between IDU & ODU the following operation: after power on need one action to change this dip switch Outdoor address setting to \\\"ON\\\" position (If the dip switch is on \\\"OFF\\\" position, Group class after power on change the \\\"OFF\\\" to \\\"ON\\\"; (physical master If the dip switch is on \\\"ON\\\" position, change the \\\"ON\\\" to unit is valid) \\\"OFF\\\" then to \\\"ON\\\") The unit will start after 6 hours preheat or within 6 hours when oil temp. meets the allowed value (allowed value lower than the standard value) OFF Heat pump (default) ON Cooling only OFF No static pressure, high speed (default) ON Ultra high-speed OFF New protocol (default) ON Old BM1_7 BM1_8 Outdoor address OFF OFF 0# (physical master unit) OFF ON 1# ON OFF 2# ON ON 3# 169","\u2461 BM2 introduction BM2_1 New communication BM2_1 BM2_2 New communication protocol type Group class BM2_2 protocol type setting (it is OFF OFF (physical master valid when BM1_6 is OFF) ON OFF Wired 9600bps general protocol (default) unit is valid) Wireless 9600bps communication BM2_3 Outdoor heat pump mode OFF Heat pump (default) setting (it is valid when ON Heating only BM1_4 is OFF) Outdoor locks the indoor Power on, Locked the indoor wireless module MAC address (default) wireless module MAC no action BM2_4 address Power on, Allow all new indoor wireless modules to join (Single-system BM2_5 (Wireless communication) OFF\u2192ON power-on search mode during debugging) BM2_6 BM2_7 Clear the master wireless Power on, Normal(default) BM2_8 module EEPROM no action completely During the debugging process, multiple systems are powered OFF\u2192ON on at the same time, which causes the master wireless module (Wireless communication) \u2192OFF to 1-1-1, then change the dip switch from OFF\u2192ON can clear the master wireless module EEPROM data. Billing module selection OFF No Billing module (Wireless communication) ON Billing module Quick start selection in high OFF Forbid quick start (default) Group class Allow quick start (physical master temperature areas ON unit is valid) Reserved OFF Default 170","\u2462 BM3 introduction BM3_1 Outdoor type selection BM3_1 BM3_2 BM3_3 Outdoor Local class BM3_2 Reserved BM3_3 OFF OFF OFF MRV5 outdoor unit Outdoor horse 8HP BM3_4 BM3_5 OFF BM3_7 Default 10HP OFF BM3_6 OFF BM3_8 12HP BM3_5 Outdoor horse power OFF ON 14HP BM3_6 setting OFF OFF ON ON 16HP BM3_7 OFF OFF OFF OFF 18HP BM3_8 OFF OFF OFF ON 20HP OFF ON ON OFF 22HP OFF ON ON ON 24HP ON ON OFF OFF 26HP ON ON OFF ON ON OFF ON OFF OFF ON OFF OFF \u2463 BM4 introduction: Group class (physical master unit is valid) BM4_1 BM4_2 Protocol selection BM4_1 ModBus Central OFF OFF Third party standard MODBUS protocol (default) BM4_2 control protocol BM4_3 OFF ON BMS protocol (HCM*) selection BM4_4 ON OFF Central control protocol (YCZ*) ~ Reversed ON ON Reserved BM4_8 ModBus central control OFF Default communication BM4_4 BM4_5 BM4_6 BM4_7 BM4_8 ModBus set control address communication address (IGU02 using the address in bracket) OFF OFF OFF OFF OFF Address1 (0) OFF OFF OFF OFF OFF OFF ON Address2 (1) OFF OFF OFF OFF OFF ON OFF Address3 (2) OFF OFF OFF OFF OFF ON ON Address4 (3) OFF OFF OFF ON ON OFF OFF Address5 (4) OFF ON \u2026 \u2026 ON OFF ON Address6 (5) ON ON ON ON OFF Address7 (6) ON ON ON Address8 (7) OFF OFF OFF Address9 (8) OFF OFF ON Address10 (9) \u2026\u2026\u2026 \u2026\u2026 ON ON ON Address32 (31) 171","Outdoor digital tube display settings \u2022 Key parts: long press the left START (SW5) control to enter, short press above UP (SW4) data increase, short press down DOWN (SW7) data reduction, long press the right STOP (SW6) control exit \u2022 Dial: SW1, SW2, SW3: set the turntable dial switch is 0 - 15 \u2022 (Note: the dial plate, with the letters A for 10, B for 11, C for 12, D for 13, E for 14, F for 15) \u2022 Display parts: LD1, LD2, LD3, LD4:4 digital tube from left to right \u2460 Indoor unit parameter view You can view the indoor machine 128 sets of parameters: SW1 and SW2 represent the indoor unit address, SW3 range is 3-14 can view the indoor unit parameters. SW1 SW2 Address 0 1 to 16 (address 0#~15#) 1 17 to 32 (address 16#~31#) 2 33 to 48 (address 32#~47#) 3 0-15 49to 64 (address 48#~63#) 7 65 to 80 (address 64#~79#) 8 81 to 96 (address 80#~95#) 9 97 to 112(address 96#~111#) 10 113 to 128(address 112~127#) SW3 Function Digital tube LD1 ~ 4 display Communication normal display indoor unit program version (1 decimal), the 3 Indoor unit communication communication interrupted normal display \u201c0000\u201d (5 consecutive round of no check and program version communication success), communication has been abnormal display \u201c---- --- -\u201d\u201d. For example: 3.9, means the indoor unit version is V3.9 4 Indoor unit failure Display indoor failure code; no failure, display 0 5 Indoor unit capacity The indoor unit capacity (unit: HP, one decimal), 1.5 HP displays 1.5 6 Indoor EEV open angle Electronic expansion valve (EEV) open angle (Unit: Pls) 7 Indoor ambient temp. Tai Ambient temperature (Unit: \u00b0C) 8 Indoor gas temperature Tc1 Gas pipe temperature (Unit: \u00b0C) 9 Indoor liquid temperature Liquid pipe temperature (Unit: \u00b0C) Tc2 LED1 shows startup mode ( O: Shutdown C: cooling H: Heating) Indoor startup mode, actual LED2 indicates actual fan speed of indoor unit (0 - stop, 1 - low wind, 2 - 10\uff08A\uff09 fan speed and SCODE medium wind and 3 - high wind) LED3 and LED4 indicate SCODE code (0~15). code For example, C311 indicates cooling running at high wind, and the SCODE is 11. 11\uff08B\uff09 Indoor set temperature Tset Indoor set temperature (Unit: \u00b0C) Display the indoor unit group number (0 means unassigned group number, self control) Method of setting group number is same with the <E2 control parameters 12\uff08C\uff09 Indoor unit consistency display and setting> control setting (Note: all the indoor unit' simultaneously setting can be set by a dial 15-0-2. 0- indoor unit self control according to the group number, 1- all indoor unit ON\/OFF at the same time 2- indoor unit self control, forbidden control at the same time) Shows whether the indoor unit has this function, 0 - No 1 - Yes Low temperature automatic Setting method is same with the <E2 control parameters display and setting> 13\uff08D\uff09 running function of indoor (Note: all the indoor unit' simultaneously setting can be set by a dial 15-1-2. unit Note: all within the machine at the same time setting can be set by dialing 15-1-0- self control, 1- all indoor are valid, 2- all indoor are invalid 172","SW3 Function Digital tube LD1 ~ 4 display (1) press START (SW5) for 2 seconds, to enter setting state, the instruction 14\uff08E\uff09 Forced indoor cooling \/ (2) press UP (SW4) or DOWN (SW7) to adjust instruction (COOL\/HEAT\/OFF). heating \/ shutdown \u2461 Outdoor unit parameter view 0~3 of SW1 is used to select the outdoor number. SW3 range of 0, 1, 15, observe the outdoor unit parameters. (the master unit can display the parameters of the other outdoor unit and the indoor units, while the slave outdoor only displays its own parameters). SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display Failure code transmitted by outdoor bus data. If no failure, display the time as second counting down from the 6 hours for pre-heating. \u2022 Press START (SW5) for 2s continuously, display 1111, and access the condition of history fault inquiry to inquire the recent 10 faults: with 0 0 Display outdoor SW4 (UP) once, sequence number will go up 1; press SW7 (DOWN) unit failure code once, sequence number will decrease 1; 2 min later, quit the setting condition automatically. \u2022 Press STOP (SW6) for 2s continuously, display 0000, then quit \u2022 When dip switch panel is at 13,0,0, press START (SW5) for 2s continuously, display 1111, thus history fault record can be cleared. 1 0 Display outdoor LD1\uff1a Display priority of outdoor unit unit priority and LD2\uff1aDisplay \u201c-\u201d outdoor unit LD3-4\uff1aDisplay outdoor unit capacity (unit: HP) capacity Outdoor Display operation unit 2 0 mode and outdoor LD1 shows O: Stop C: Cooling H: Heating address 3 unit operation LD2 to LD4 show: 60 shows 60% capacity output 0-3 output ratio 0 Outdoor fan 1 345 representation 345rpm speed \u2022 Press START (SW5) for 2s continuously, display 1111, then to set: 4 0 Outdoor fan 2 DOWN (SW7) once, wind speed will decrease 1 level. 5 min later, quit speed the setting condition automatically. \u2022 Press STOP (SW6) for 2s continuously, display 0000, then quit the 5 0 Frequency 110 representation 110.0Hz converter INV1 Press START (SW5) for 2 seconds, display 1111, enter the set state: current frequency 1Hz, every 1 times DOWN (SW7) frequency drop 1Hz; 5min after Frequency automatically quit the set state. 6 0 converter INV2 Press STOP (SW6) for 2 seconds, display 0000, quit the set state, current frequency \uff08When the system is faulty, the compressor is forbidden to start.\uff09 173","SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display 7 0 Outdoor unit LEVa1 open degree 0---470pluse Press START (SW5) for 2 seconds, 1111, enter the 8 0 Outdoor unit LEVa2 open degree 9 0 Outdoor unit LEVb open degree open, press DOWN (SW7) the valve is fully closed; 2min later automatically exit the setting state 10\uff08A\uff09 0 Outdoor unit LEVc open degree Press STOP (SW6) for 2 seconds, display 0000, quit 11\uff08B\uff09 0 Outdoor unit solenoid valve LD1\uff1a 4WV \uff1a 1 ON 0 OFF output LD2\uff1a SV1 \uff1a 1 ON 0 OFF LD3\uff1a SV3\uff1a 1 ON 0 OFF Outdoor LD4\uff1a Reserved\uff0cDisplay \u201c-\u201d unit LD1\uff1a SV6\uff1a 1 ON 0 OFF LD2\uff1a SV9\uff1a1 ON 0 OFF address 12\uff08C\uff09 0 Outdoor unit solenoid valve LD3\uff1a SV10\uff1a 1 ON 0 OFF 0-3 output LD4\uff1a SV11\uff1a 1 ON 0 OFF 13\uff08D\uff09 0 Outdoor unit solenoid valve LD1\uff1a SVX\uff1a 1 ON 0 OFF output LD2\uff1a SVY\uff1a 1 ON 0 OFF LD3\uff1a Reserved\uff0cDisplay \u201c-\u201d 14\uff08E\uff09 0 Heater output LD4\uff1a Reserved\uff0cDisplay \u201c-\u201d 15\uff08F\uff09 0 Program version LD1\uff1a CH1\uff1a 1 ON 0 OFF LD2\uff1a CH2\uff1a 1 ON 0 OFF LD3\uff1a CHa \uff1a 1 ON 0 OFF LD4\uff1aReserved\uff0cDisplay \u201c-\u201d 1 means Ver1.0 SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display 1 Unit: kg, 2 decimal 0 1 Pd 1 Ps Unit: 2 1 Td1 1 Td2 3 1 Tdef 1 Toil1 Outdoor 4 1 Toil2 unit 5 1 Toci1 7 1 Ts address 8 Th 0-3 9 14\uff08E\uff09 15\uff08F\uff09 SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display 1 15\uff08F\uff09 Tao Unit: oC 2 15\uff08F\uff09 Pd_temp Unit: Min Unit: Min 4 15\uff08F\uff09 Ps_temp Unit: A, 1 decimal Unit: A, 1 decimal 5 15\uff08F\uff09 Tliqsc Unit: V Outdoor 6 15\uff08F\uff09 Tsco Unit: V unit address 8 15\uff08F\uff09 Inverter compressor INV1 ON\/OFF time 9 15\uff08F\uff09 Inverter compressor INV2 ON\/OFF time 0-3 10\uff08A\uff09 15\uff08F\uff09 Inverter compressor INV1 current CT 11\uff08B\uff09 15\uff08F\uff09 Inverter compressor INV2 current CT 12\uff08C\uff09 15\uff08F\uff09 Inverter compressor INV1 DC voltage 13\uff08D\uff09 15\uff08F\uff09 Inverter compressor INV2 DC voltage 174","SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display Unit: oC Outdoor 14\uff08E\uff09 15\uff08F\uff09 Inverter compressor INV1 module temperature unit address 15\uff08F\uff09 15\uff08F\uff09 Inverter compressor INV2 module temperature 0-3 System status display and control (master unit) SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display 00 2 Refrigerant type 410A means 410A refrigerant 01 2 The outdoor units total LD1\uff1aThe total number of outdoor unit 02 2 number and total capacity in LD2\uff1aDisplay \u201c-\u201d 03 2 one system LD3\/ LD4\uff1aTotal outdoor unit capacity (unit: HP) 04 2 05 2 For example: 3-48 means 3 outdoor units, total capacity is 06 2 07 2 48HP 08 2 Total indoor unit capacity 50 means 50HP 09 2 The indoor units quantity in For example: 64 one system Running indoor QTY Thermostat ON indicates indoor running Indoor QTY whose operation modes are as the same as E.g.: 13 indoors that of outdoor Cooling target temperature Unit: \u00b0C Heating target temperature Automatic recovery of When the outdoor stop, press START (SW5) for 2 seconds, refrigerant display 1111, start. (the setting is invalid when the outdoor Note: after recovery must unit running) cancel the setting or re-power Press STOP (SW6) for 2 seconds, display 0000, stop on) Display the amount of the The amount of refrigerant is displayed as a percentage refrigerant and the setting of When the outdoor stop, press START (SW5) for 2 seconds, the refrigerant charging (after charging must cancel amount. (the setting is invalid when the outdoor unit the setting or re-power on) running) Press STOP (SW6) for 2 seconds, display 0000, stop Trial operation setting When the outdoor stop, press START (SW5) for 2 seconds, 0 10\uff08A\uff09 2 (after trial operation must display 1111, start. (the setting is invalid when the outdoor cancel the setting or re-power unit running) on) Press STOP (SW6) for 2 seconds, display 0000, stop 0 11\uff08B\uff09 2 Outdoor unit mode 0-normal C-cooling only H-heating only 0 12\uff08C\uff09 2 Indoor unit expansion valve Press START (SW5) for 2 seconds, display 1111, indoor fully open valve fully open 2 minutes, 2 minutes after the valve automatic closed 0 13\uff08D\uff09 2 All the indoor unit in cooling Press START (SW5) for 2 seconds, display 1111, open\uff1b 0 14\uff08E\uff09 2 All the indoor unit in heating Press STOP (SW6) for 2 seconds, 0000, close 0 15\uff08F\uff09 2 Cancel all manual control Press START (SW5) for 2 seconds, display 1111 cancel; or (running class) press STOP (SW6) for 2 seconds, display 0000, cancel Remove all manual control (part), all indoor unit close. 175","E2 control parameters display and setting Each need to be set separately, setting method: (2) Press UP (SW4) or DOWN (SW7) to adjust parameters (3)After the adjustment is completed <A> In the current state of the code, press STOP (SW6) for 2 seconds within effectively set the time , show 0000, keep , waiting for 2 minutes then re-power on. <B> In the current state of the code, press STOP (SW6) for 2 seconds exceeds effectively set the time, or change the <C> Effective setting time: the group number setting of the indoor unit simultaneously ON\/OFF and the setting of low temperature automatic operation function, the effective setting time is 10 minutes, and other functions is 30 seconds. SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display Control range 15\uff08F\uff09 0 Indoor simultaneously 0- indoor unit self control according to the 2 ON\/OFF outdoor control group number, 1- all indoor unit ON\/OFF Group class at the same time 2- indoor unit self control, (physical selection forbidden control at the same time) master unit is valid) Indoor low temperature 0- self control, 15\uff08F\uff09 1 2 automatic running outdoor 1- all indoor are valid 15\uff08F\uff09 2 control selection 2- all indoor are invalid 2 Pipe length selection 0\uff1a short pipe length; 1\uff1amiddle pipe length\uff1b 2\uff1along pipe length 15\uff08F\uff09 3 2 Defrosting conditions 0- normal area, selection 1- area easy to frost \uff1b 15\uff08F\uff09 4 2 Start mode priority 1- last open is priority 2- cooling priority\uff1b 3- heating priority 15\uff08F\uff09 5 2 Capacity over match 0- allowed 1- forbidden 15\uff08F\uff09 6 Heating limitation when 0- no limitation, 15\uff08F\uff09 7 2 outdoor temp 1-limitation over 25 degree 0-without silent operation\uff0c 1- silent operation 1\uff0c 2 Silent running option 2- silent operation 2\uff0c 3- silent operation 3\uff0c 4- silent operation 4 5- silent operation 5 6- silent operation 6 15\uff08F\uff09 8 2 Snow-proof operation setting 0-without snow-proof operation\uff0c 1-snow-proof operation The stopping slave outdoor 15\uff08F\uff09 9 2 fan motor running selection 0-stop\uff0c when the master unit in 1-run heating 15\uff08F\uff09 10 (A) 2 Height drop between indoors 0-exit height drop 1-no height drop 15\uff08F\uff09 11 (B) 2 Height drop between indoor 0-normal and outdoor 1- high drop and outdoor is higher 2-high drop and outdoor is lower 15\uff08F\uff09 12\uff08C\uff09 2 Power restrain operation 0- E2 value, control mode selection 1- external contact DRM Power restrain operation 15\uff08F\uff09 13\uff08D\uff09 2 capacity output ratio Allow maximum capacity output, total of 11 selection (E2 control method grade, 0 grade is 0%, 10 grade is100% is valid) 176","SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display Control 15\uff08F\uff09 14\uff08E\uff09 2 range Expansion valve LEV fault 0- not shielded, normal detection shield selection 1- shielded Local class 15\uff08F\uff09 15\uff08F\uff09 2 High ambient temperature 0- no limitation, Group class (physical limitation in cooling 1-limitation master unit is valid) Outdoor unit valve control SW1 SW2 SW3 Functions Operation methods \u2022 Press START (SW5) for 2s continuously, display 1111, then to quit, or Cancel all the press STOP (SW6) for 2s continuously, display 0000, then quit the set. 6 15 (F) 2 manual controls \u2022 Cancel items: Movable component control by hand such as compressor, motor, (component type) electronic expansion valve (LEV), solenoid valve (SV) and so on (including evacuation and charging; excluding rated operation, compulsory operation, indoor run\/stop, etc.) Examination of local EE data SW1 SW2 SW3 Function Display with digital tube LD1~4 0 0 The EE data of address 000H (Version E2) 0 1 The EE data of address 001H \u2026 \u2026\u2026 12 (C) 0 15 (F) The EE data of address 00FH (system parameters information) 1 0 The EE data of address 010H Calculating address: addr=SW2\u00d716+SW3 \u2026 \u2026 \u2026 Data display: hex display, H means hex 1 The EE data of address 01FH number 15 (F) \u2026 \u2026\u2026 15 (F) 15 (F) The EE data of address FFH 0 0 The EE data of address 100H The last 256 bytes data display of local EE 0 1 The EE data of address 101H (Failure information) \u2026\u2026 \u2026\u2026 \u2026\u2026 Calculating address: addr=SW2\u00d716+SW3 13 (D) 1 15 (F) The EE data of address 11FH Data display: hex display, H means hex \u2026\u2026 \u2026\u2026 \u2026\u2026 number. When the dial-up wheel is on 13 0 0, press 15 (F) 15 (F) The EE data of address 1FFH START (SW5) for 2 seconds, then the last 256 bytes of EE will be cleared. Special function (local) SW1 SW2 SW3 Function Display with digital tube LD1~4 0 0 Code 0 1 Outdoor type MRV 5: 256 INV1 module history fault 0 3 communication data MRV 5: 0 INV2 module history fault 0 4 communication data Long press START key to display INV1\/ INV2 module history fault communication data (500 15 (F) bytes), after display, automatically canceled. Long press STOP key to cancel immediately. 0 5 BM1 and BM2 setting state Hexadecimal display, 0 6 BM3 and BM4 setting state LD1 and LD2 display BM1 LD3 and LD4 display BM2 Hexadecimal display, LD1 and LD2 display BM3 LD3 and LD4 display BM4 177","21. Outdoor system control function 21.1 Compressor control Generally, the compressor frequency is controlled according to the target Ps during cooling. During the control process, Pd, Td\/TOIL, PS, etc. are given priority. Generally, the compressor frequency is controlled according to the target Pd during heating. During the control process, Pd, Td\/TOIL, PS, etc. are given priority. Single and double compressor switching based on system load and compressor frequency during dual compressor operation 21.2 Electronic expansion valve control Cooling: when startup, the electronic expansion valve is maintained at 100 pls and the electronic expansion valve is fully open after startup. Heating: When heating, the electronic expansion valve is usually superheated to 4 degrees. SH = Toci1-ET=4 (\u00b0C) 21.3 Fan motor control \u2460 Control of MRV 5 series DC motor The air supply speed of outdoor unit can be set from speed 0 to 22 in accordance with the operating mode. The operating is commonly at speed 1 - 22, and it is CVT (Continuously Variable Transmission) control between speed 1 and 22. \u2461 Air supply motor: range of number and rotating speed (unit: rpm) < Outdoor fan motor control (usually control \/ high static pressure control) > Level Double fan Single fan 24 (high static pressure) 1100+1100 1000 1020+1020 1000 22 1000+1000 940 21 970+970 920 20 910+910 880 19 860+860 845 18 800+800 820 17 770+770 760 16 650+650 710 15 560+560 680 14 520+520 640 13 460+460 610 12 410+410 560 11 360+360 520 10 330+330 475 9 300+300 440 8 280+280 415 7 210+210 370 6 190+190 320 5 280 4 280 230 3 230 200 2 200 160 1 160 0 0 0 178","The highest speed for each model under normal running condition Horse power 8 Single fan 12 14 16 Speed 0~16 10 0~17 0~19 0~19 0~16 Horse power 18 22 24 26 Speed 0~19 Double fan 0~21 0~22 0~22 20 0~20 a. In cooling mode Startup procedure: When compressor starts up, if Ta\u226535\u00b0C, the outdoor motor will run at the highest class; if 25\u00b0C\u2264Ta<35\u00b0C, the outdoor motor will run at the 15class; if 15\u00b0C\u2264Ta<25\u00b0C, the outdoor motor will run at the 6 class, if Ta<15\u00b0C, the outdoor motor off, the outdoor motor will run automatically after 45 seconds. In operation, the motor control by the high pressure. If Pd<15kg, the motor will run at 1 class, off after 1min; if15kg\u2264Pd<20kg, the motor will reduce 1 class every 20 seconds, until the lowest class; if 20kg\u2264Pd<25kg, the motor run at the current speed, if 25kg\u2264Pd<32kg, the motor will raise 1 class every 20 seconds, if Pd\u226532kg, the motor will run at the highest class immediately. b. In heating mode When compressor starts up, if Ta<10\u00b0C, the outdoor motor will run at the highest class; if 10\u00b0C\u2264Ta<20\u00b0C, the outdoor motor will run at the 5 class; if Ta\u226520\u00b0C, the outdoor motor will run at the 1 class; the outdoor motor will run automatically after 60 seconds. In operation, the motor control by the high pressure. If Pd>37kg, the motor will be off immediately; if 33kg<Pd\u226437kg, the motor will reduce 1 class every 20 seconds; if 28kg<Pd\u226433kg, the motor run at the current speed, if 24kg<Pd\u226428kg, the motor will raise 1 class every 20 seconds, if Pd\u226424kg, the motor will run at the highest class immediately. 21.4 Start Control \u2460 Evaluate if the compressor is started according to the superheat of oil temperature or the heating time of energized heating trip, in order to prevent prolonged suspension compressor oil from being severely diluted by refrigerant. The compressor starting conditions are as follows: \u2461 Compressor start protecting control: Within the 3 min after starting, the operating frequency of compressor keeps at 50rps or 60rps. 3 min later, if Td SH is higher than 25\u2103 , withdrawal from the starting process and conduct target Pd or target Ps control; 3min later, if Td SH is lower than 25\u2103 , the frequency goes up to 100rps and withdrawal from the starting until the Td SH is higher than25\u2103 or the starting time reaches 15min. In the process of starting, protecting control has the priority. 179","[Note] Frequency maintained within the 3 min after starting is as follows: \u2462 Restart of the compressor 1. In the control of the compressor, in order to prevent the starting at differential pressure, it must take some time to balance the high and low pressure after stopping fully, the restarting will delay automatically, and the compressor can restart after stopping for 3 to 5 minutes. 2. When the operating mode shifts reversely from [cooling. dehumidifying] to [heating], the all compressors shall stop and delay 3~5 min to restart. 3. When power on, it shall delay 3~5 min to restart the compressor. 4. Before restart the compressor, when the oil temperature cannot meet the start requirement, it will delay the start until oil temperature can meet the requirement. \u2463 Cycle start function of compressor 1. According to different load of indoor unit, determine the number of compressors needing to start and outdoor units needing to start. 2. If there is only 1 outdoor unit but 2 compressors, shift the priority of compressor 1 and 2 every 4 hours. 3. If there are several outdoor units, the priority of these outdoor units shall be shifted every 8 hours. If the outdoor unit with 2 compressors is operating, it shall shift the priority of compressor 1 and 2 every 4 hours. 4. Shift the priority of compressor and outdoor unit to meet shift interval in the following conditions. 1) When all of compressor and outdoor unit are ON or OFF at the same time, the priority can be shifted directly; 2) When all of outdoor unit and compressor operate in the process of oil return and deforesting, they can shift the priority; 3) When outdoor unit and compressor with higher priority stop upon failure alarm, the priority can be shifted directly without evaluating the interval period. \u2464 Changes of the number of compressor (take the multiple connection of 3 double compressor of outdoor unit as example) Compressor shifts its number of operating with the different operating frequency according to the following pictures. \u203b No.1 in the following picture represents the compressor with the highest priority, and outdoor unit 1 represents the outdoor unit with the highest priority, and so on. frequency, only No. 1 compressor works. 180","2. When operating frequency of one compressor rises up to the 75% of the highest frequency, two compressors in the outdoor unit 1 will work at the same time. 3. When the operation output ratio of the outdoor unit 1 (actual operating frequency\/total operating frequency) continue to rise up to the 75%, two compressors in the outdoor unit 2 will also work at the same time. 4. When the total operation output ratio of the outdoor unit 1 and outdoor unit 2 (actual operating frequency\/total operating frequency) rises up to the 75%, two compressors in the outdoor unit 3 will also work at the same time. 5. When the total operation output ratio of the outdoor unit 1, outdoor unit 2 and outdoor unit 3 declines to the 25%, two compressors in the outdoor unit 3 will stop at the same time, outdoor unit 1 and outdoor unit 2 continue to operate. 6. When the total operation output ratio of the outdoor unit 1 and outdoor unit 2 declines to the 25%, two compressors in the outdoor unit 2 will stop at the same time, and the two compressors in outdoor unit 1 continue to operate. 7. When the total operation output ratio of the outdoor unit 1 declines to the 25%, the No. 2 compressor of outdoor unit 1 will stop and the No. 1 compressor continues to operate. 181","21.5 Oil return control 1. Entering condition When outdoor total running capacity is over 25% and less than 75% for 4 hours, or outdoor total running capacity is less than 25% for 2 hours, the system will enter oil return operation. *When outdoor total running capacity is over 75% for 10minutes continuously, the oil return time will be cleared. *In defrosting operation, when outdoor total running capacity is over 75% for 5 minutes continuously, the oil return time will be cleared. 2. Oil return procedure: All outdoors start up, and run with 75% of total capacity in cooling mode; In oil return course, outdoor leva1, 2 open to 250pls; In oil return course, THERMO ON, indoor valves 250pls, THERMO OFF, indoor valves 125pls; when Tdi or Toil is over 105\u00b0C, indoor valve will open larger 10%. In oil return, Levb OFF. Oil return quit condition: After 8 minutes & 36 2 21.6 Defrosting control When one of the running outdoors reaches the defrosting condition, it will send defrosting signal to the master unit. After the master unit receives defrosting signal, it will send defrosting signal to all slave outdoors. All outdoor units will self-control after receiving the signal. Defrost operation is also performed on the outdoor unit that has not been operated since the previous defrosting. Enter condition: \u30fb\uff06 \u30fbTao \u2264 20\u2103 \u30fbOR \u30fbAfter 50 minutes of heating start \u25cf \u30fbPrevious defrosting ~ Heating operation accumulated time exceeds 50 minutes \u25cf \u30fbOR \u30fbA: Tao \u22654 \u2103, Tdef \u2264 -6\u2103 lasts 5 minutes \u25cf \u30fbB: -6\u2264 Tao \uff1c 4 \u2103, Tdef \u2264 0.8 Tao-8.5 lasts 5 minutes \u30fbC: -15\u2264 Tao \uff1c -6 \u2103, Tdef \u2264 (5Tao-72)\/7\/1.08 lasts 5 minutes \u30fbD: Tao \u2264 -15 \u2103, Tdef \u2264 -20 lasts 5 minutes \u30fbX : If the following conditions are met during the oil return operation, the accumulated running time is cleared. \u30fbOR \u30fboutdoor Tdef \u226510\u2103 lasts 1 minute \u25cf \u30fboutdoor Tdef \u226515\u2103 lasts 10 seconds 182","Quit condition\uff1a \u30fbOR \u30fbAfter 12 minutes of defrosting operation \u30fbOR \u30fb outdoor Te \u226515 \u2103 lasts 1 minute \u30fb outdoor Te \u226520 \u2103 lasts 30 seconds \u30fbOR \u30fbPd \u2265 3.5MPa The program reserves the enhanced defrosting control, to solve the problem of defrosting is not clean, the quit condition is changed to \u30fbOR \u30fbAfter 15 minutes of defrosting operation \u30fbOR \u30fb outdoor Te \u226520 \u2103 lasts 1 minute \u30fb outdoor Te \u226530 \u2103 lasts 30 seconds \u30fbOR \u30fbPd \u2265 3.5MPa 21.7 Pump down operation After the liquid refrigerant is retained in the gas-liquid separator, the refrigeration oil in the compressor is diluted to reduce the lubricity, and can cause Liquid compression, which may damage the compressor. This control is to prevent these situations happening. Pump down operation for cooling The outdoor unit frequency is 25%* rated frequency, the indoor LEV is fully closed, and other automatic control, after running for a period of time, the exhaust superheat degree meets the requirements and then exits. Pump down operation for heating Outdoor unit frequency 25%* rated frequency, outdoor unit LEV fully closed, other automatic control, after running for a period of time, the exhaust superheat degree meets the requirements and then exits 21.8 High pressure protection In order to maintain normal cooling and heating operation, high pressure control is performed by a high pressure sensor. Limit the upper limitation of the compressor operating frequency and operating under a certain high pressure value Normal \u00b7>3.7MPa Pd=3.7MPa operation \u00b7& \u00b7\u22643.7MPa Upper limitation control \u00b7When the limitation control is completed * Restart after 3 minutes \u203b1 High pressure Error stop switch OFF \u203b Locked if it occurs 3 times in an hour 183","21.9 Low pressure protection Normal \u00b7\uff1c0.15Mpa SV1: ON Ps\uff1c0.1Mpa operation \u00b7 \u22650.20Mpa Compressor speed upper limitation control \u22650.15Mp \uff08Max. 30rps\uff09 *Restart after 5 minutes \u00b7\uff1c0.05Mpa \u00b7\uff1c0.03Mpa Protection stop Error stop 21.10 The temperature of discharge too high control \u00b7Td high temperature side (\u2264120\u00b0C) is controlled by the \u201cindoor unit SH correction + SV3 LEVb control + compressor frequency control\u201d. (Note) Compressor frequency control is performed by fuzzy control. . When the discharge temperature Td\u226595\u00b0C, the SV3 is turned on. When the discharge temperature Td\u2265105\u00b0C, the compressor reduce the frequency When the discharge temperature Td \u2264 90\u00b0C, Recovery usually control 21.11. The temperature of discharge too low control In cooling: \u00b7Td low temperature side (< stage is compressor output control\/ the third stage is minimum number of outdoor units running control Normal operation \u00b7\ufe64CT+20\u00b0C Indoor SH \u00b7\ufe64CT+15\u00b0C \uff08Indoor SH constant control\uff09 correction control \u203b2 \u00b7& \u00b7\u2265CT+20\u00b0C \uff08Td SH20\u00b0C constant\uff09\u00b7& \u00b7\u2265CT+15 20\u00b0C \u00b7Correction control completed \u00b7Correction control completed \u00b7\ufe64CT+10\u00b0C \u00b7\ufe64CT+10\u00b0Lasts 5 minutes Compressor output Min. number control correction control of outdoor unit \uff08Td SH15\u00b0C constant\uff09 Protection Error stop stop *Restart after \u203bLocked if it occurs 3 times in an hour 3 minutes 184","In heating: \u00b7Td low temperature side (< stage is compressor output control\/ the third stage is minimum number of outdoor units running control Normal operation \u00b7\ufe64CT+25\u00b0C Outdoor SH \u00b7\ufe64CT+20\u00b0C \uff08Indoor SH correction control \u203b2 constant control\uff09 \u00b7& \u00b7\u2265CT+25\u00b0C \u00b7& \u00b7\u2265CT+20 25\u00b0C \u00b7Correction control completed \u00b7Correction control completed \u00b7\ufe64CT+15\u00b0C Min. number contro\u00b7l \ufe64CT+10\u00b0 Compressor rps \u203b3 of outdoor unit correction control \uff08TdSH20\u00b0C constant\uff09 Protection Error stop stop 21.12. Radiator protection control By controlling the frequency of the compressor to control the temperature of the radiator, and the radiator temperature is usually controlled at 95 \u00b0 C. Above 95 \u00b0 C, the outdoor fan increases the speed. 21.13. Anti-snow protection 21.14. Heater control When the system is running, control the heater according to the following picture. CH: ON \u2192 60 65 OFF Oil temperatureToil(\u00b0C\uff09 When the compressor oil temperature Toil is 60-65 \u00b0 C, it starts from ON. CH: Heater (Crank Case Heater) 185","21.15 Target pressure control \u2460 Cooling low pressure control Target pressure Ps when cooling Remarks Factory default setting Long piping setting 6.5kg Medium piping setting 7.5kg Short piping setting 8.3kg \u2022 During cooling, the operating frequency of compressor is fuzzy controlled based on target Ps. \u2022 The frequency of compressor goes down and Ps goes up; the frequency of compressor goes up and Ps goes down. \u2022 During cooling, if the low pressure reaches 1.05MPa, control the LEV of all indoor units to make sure it will not exceed 1.05MPa. it is short piping; 30-90m, medium piping; more than 90m, long piping. installation in site. \u2461 Heating high pressure control Target pressure Pd when heating 30kg Remarks Long piping setting 28kg Factory default setting 26kg Medium piping setting Short piping setting During heating, the operating frequency of compressor is fuzzy controlled based on target Pd. The frequency of compressor goes down and Pd goes down; the frequency of compressor goes up and Pd goes up. [Note] For heating capacity, if the high pressure is higher, the capacity is higher. However, if the high pressure is higher, the COP of unit will be lower. 21.16 Overheating protection control \u2460 When the temperature at the top of compressor rises, the corresponding SV3 is started to conduct the liquid bypass cooling. (Refer to Figure) Td high temperature side ( \u2266 120\u2103 ) control \/ SV3 control When Td \u2265100\u2103 When Td \u2265105, control the compressor frequency 186","21.17 Current protection control \u2460 If the current of compressor exceeds the stipulated upper limit value, the operating frequency is reduced for control before the current changes to exit value or below. \u2461 When the current cannot reach the upper limit value or below even at the lowest rotating speed (20rps), the compressor will stop operating. \u2462 If the current reaches the exit value or below, it will get back to the target rotating speed. Compressor ANB42 ANB52 ANB66 ANB78 ANB87 Rated Current 33A 34A 40A 45A 50A 21.18 Heating is prohibited When the outdoor temperature is greater than or equal to 25 degrees, the setting can be made through the outdoor unit rotary dial, and the outdoor is prohibited from starting. SW1 SW2 SW3 Function Digital tube LD1 ~ 4 display 15 6 2 Heating limitation when 0- no limitation, outdoor temp 1-limitation over 25 degree 187","22. Failure code Master unit Indication Failure code Failure description Remarks digital tube on wired controller Defrosting temp. display sensor Tdef failure (hex) Ambient temp. 20-0 14 sensor Tao failure AD value is below 11 (open circuit) or over Resumable Suction temp. 1012 (short circuit) for 60 seconds, sensor Resumable 21 15 sensor Ts failure has no alarm when abnormal in cooling Resumable 22-2 16 Discharging temp. mode. 23-0 17 sensor Td1failure Resumable 23-1 17 Discharging temp. AD value is below 11 (open circuit) or over sensor Td2 failure 1012 (short circuit) for 60 seconds, sensor Resumable 24-0 18 has no alarm when abnormal in cooling Oil temp. sensor Th mode. Resumable 24-1 18 failure 24-2 18 AD value is below 11 (open circuit) or Once Oil temp. sensor over 1012 (short circuit) for 60 seconds. un- 25-0 19 Toil1 failure If Tao\u22640\u2103 , no need to detect the open resumable Oil temp. sensor circuit failure (AD value is below 11.) Resumable 26-0 1A Toil2 failure 26-1 If AD value is below 11 (open circuit) or 26-2 1B Heat exchanger over 1012 (short circuit) for 60 seconds, 27-0 1B inlet temp. Toci1 alarm. 27-1 1C failure 28 If AD value is below 11 (open circuit) or Outdoor unit and over 1012 (short circuit) for 60 seconds, 29 1D indoor unit commu- alarm. If Tao<0\u2103 , after compressor nication failure running 5 minutes to detect open circuit failure. Oil temp. too high AD value is below 11 (open circuit) or over protection 1012 (short circuit) for 60 seconds, sensor \uff08ToiI1\uff09 has no alarm when abnormal in cooling Oil temp. too high mode. protection \uff08Toil2\uff09 When all indoor units are lost, the alarm High pressure sen- will last for 2 minutes sor Pd failure The searched indoor unit quantity is less Low pressure sen- than the set quantity for continuous 270 sor Ps failure seconds The searched indoor unit quantity is more than the set quantity for continuous 170 seconds Toili \u2265120\u2103\uff08E) continuous 2 sec, and over the set value, then stop and alarm. The oil temp. 10\u2103 lower than the alarm condition after stop. 170s automatic recov- the failure. If AD value is below 11 (open circuit) or over 1012 (short circuit) for 30 seconds, alarm. If AD value is below 11 (open circuit) or over 1012 (short circuit) for 30 seconds, alarm. If Tao> = 40 \u2103 , do not detect short circuit faults. 188","Master Indication Failure code Failure description Remarks unit on wired controller High pressure continuous 2sec, alarm. Once digital switch HPS1 failure. un- tube (hex) failure resumable display High pressure If AD value is below 11 (open circuit) or over 30-0 1E switch HPS2 1012 (short circuit) for 60 seconds, alarm, Resumable failure sensor has no alarm when abnormal in heat- 30-1 1E Heat exchanger ing mode. outlet temp. Tsco 32-0 20 failure Liquid pipe SC 32-1 20 temp. of subcooler Tliqsc failure 33-0 AT24C04 EEPROM communication failure 33-2 33-3 Once 34-0 34-1 21 EEPROM failure AT24C04 EEPROM data check failure(model un- code, check, etc.) 35-0 resumable 35-1 IM EEPROM data or communication failure Discharging temp. Td1 \uff0f Td2\u2265130\u2103\uff08E\uff09continuous 2sec, and 22 too high protection over the set value, then stop and alarm. after Once con- 22 \uff08Td1\uff09 - Discharging temp. stop the discharge temp. is lower than the alarm condition 10\u2103 recovery automatically. sumable too high protection \uff08Td2\uff09 failure. minutes, if the below conditions can be met for continuous 10 seconds, that is conversing successfully: \u30fb\uff06 \u30fbThe outdoor compressor running nor- mally \u30fb\uff06 \u30fb\uff06 \u30fbTd1 \uff0d Tdef1 \u2267 10\u2103 23 4-way valve \u30fbTd2 \uff0d Tdef1 \u2267 10\u2103 reversing failure \u30fbPd \uff0d Ps \u2267 \u03b2Mpa \u203bOtherwise, stop protection. Once con- \uff08Tao \uff1e -10\u2103\uff0c\u03b2=0.30\uff1bTao \u2266 -10\u2103\uff0c - \u03b2=0.20\uff09 sumable *4-way valve OFF starts up again after 3 min- utes failure. If there is 4-way valve of slave unit not electri- 23 4-way valve up for 20 min, reversing failure failure. 189","Master unit Indication Failure description Remarks digital tube on wired controller In normal operation (exclude start up, Once con- display defrosting, oil return, remain, stop), un-resum- (hex) \u30fb\uff06 \u30fb Toil < CT+10\u2103 able \u30fbOR \u30fbTSs-ET \u2266 2\u2103 36-0 24 Oil temp. too low \u30fbTdlorTd2 \u2266 5\u2103 Once protection\uff08Toil1\uff09 if continuous 5 minutes, the unit stops un- 36-1 24 and alarm, then resumes automatically. resumable Oil temp. too low If it occurs 4 times in an hour, lock the Once 39-0 27 protection\uff08Toil2\uff09 alarm. un- After compressor is running (except resumable 39-1 27 Low pressure sensor for start, residual operation), if in 28 Ps too low protection cooling, Ps<0.10MPa; in heating, Ps< Resumable 40 2B 0.05MPa, for continuous 5 minutes, or 2B Compressor ratio \u03b5 too in cooling, Ps<0..05MPa; in heating, 43-0 2D high protection Ps< 0.03MPa, for continuous 1s,stop 43-1 and alarm. then resume automatically. 45 2E High pressure sensor 46-0 Pd too high protection the failure. 46-1 2F After compressor is running, compres- 46-4 Discharging temp. sen- sion ratio \u03b5 \uff1e 10.0 for continuous 5 46-5 sor Td1 too low protec- minute, or ratio \u03b5 \uff1e 11.0 for continuous 47 tion 1 minute then stop and alarm. then re- Discharging temp. sen- sume automatically. If it occurs 4 times sor Td2 too low protec- tion After compressor is running, if Communication failure Pd\u22654.15MPa, stop and alarm, then re- between outdoors sume automatically. If it occurs 3 times Communication with INV1 board failure In normal operation (exclude start up, Communication with defrosting, oil return, remain, stop), if INV2 board failure Td \uff1c CT+10\u2103 for continuous 5 min- Communication with utes, stop and alarm. then resume fan motor module automatically. If it occurs 3 times in an board 1 failure hour, lock the alarm. Communication with fan motor module No communication within 30 seconds board 2 failure continuously (E) Communication with wireless communica- No communication within 30 seconds tion module failure continuously No communication within 30 seconds continuously No communication within 30 seconds continuously No communication within 30 seconds continuously Can\u2019t detect the wireless communication module within 120 seconds continuously, alarm 190","Master unit Indication Failure code Failure description Remarks digital tube on wired controller LEVa1 over Resum- display current protection able (hex) LEVa2 over 51-0 current protection Once LEV driver chip detection un-resum- 51-1 33 LEVb over current LEV driver chip detection able 51-2 protection LEV driver chip detection LEV driver chip detection Reset 51-3 LEVc over current LEV driver chip detection Un- 52-0 protection resumable 52-1 52-2 LEVa1 open circuit Resum- 52-3 able LEVa2 open circuit LEV driver chip detection 74 34 LEVb open circuit LEV driver chip detection 4A LEVc open circuit LEV driver chip detection 75-0 4B Emergency stop function switch The CN18-3,4 STOP terminal of main PCB 76-0 4C failure open circuit 76-1 53 76-2 Too small pres- If Pd-Ps\u22640.35MPa for 3 minutes, the outdoor 83 sure drop between unit protection stop. (after the second time, high pressure and the last time will +150s.) 99-0 low pressure \u2022 5 minutes after stopping protection, restart. \u2022 If there are more than 9 times of stopping 99-1 63 Incorrect outdoor protecting within 3 hours, Error stop. unit quantity, ad- Slave unit quantity setting is not in confor- 99-2 dress or capacity mance with data in EEPROM of the master setting unit. Slave unit address setting is not in Outdoor unit mod- conformance with data in EEPROM of the el are set incor- master unit. rectly Slave unit capacity setting is not in conformance with data in EEPROM of the The normal master unit. running mode Outdoor models are set incorrectly or do not is stop\\\\ cooling match with the master model \\\\ heating, and other modes are System abnormality, chip interference. abnormal. The system is abnormal and does not meet The defrosting and the exit conditions. check the sensor. oil return process The system is abnormal and does not meet of the master the exit conditions. check the sensor. unit exceeds the normal time The defrosting and oil return process of the slave unit exceeds the normal time 191","Master unit Indication Failure description Remarks digital tube on wired controller 1.the high and low pressure Resumable display differential of the slave unit does not (hex) meet the condition of <0.2MPa If it occurs 4 2.check the SV1 and pressure times in an 99-3 The master unit start sensor hour, con- -up operation process The system is abnormal and does 99-4 63 exceeds the normal not meet the exit conditions. check - the sensor. ure. Once 99-5 6E time 1.the high and low pressure un-resumable 6E The master unit stop differential of the slave unit does not 110-0 meet the condition of <0.2MPa If it occurs 4 110-1 6F operation process 2.check the SV1 and pressure times in an 110-4 exceeds the normal time sensor hour, con- 110-5 70 111-0 70 The start-up and stop Module hardware over current - 72 process of the slave ure. Once 111-1 72 unit exceeds the normal In the course of compressor startup un-resumable or running, the unit can not detect 112-0 73 time the rotor position for 6 times, stop 112-1 for 5s and then the INV control 112-4 75 Compressor module board resumes automatically. 112-5 75 hardware over current 114-0 If temp. \uff1e 94\u2103 , alarm. 114-1 77 Fan motor module If temp.\u226494\u2103 , INV control board 114-4 hardware over current resumes automatically. 114-5 115-0 Compressor out of con- If DCBUS voltage \uff1c DC420V, alarm trol If DCBUS voltage \uff1e DC420V, INV 115-1 control board resumes automatical- Compressor module ly. 117-0 radiator temp. too high If DCBUS voltage \uff1e DC642V\u3001 117-1 alarm 117-4 Fan motor module radi- If DCBUS voltage \uff1c DC642V, INV 117-5 ator temp. too high control board resumes automatical- 119-0 ly. Compressor module DC 119-1 BUS under voltage Module software over current Fan motor module DC Sensor for detecting current of BUS under voltage compressor module is abnormal. The wires of compressor not Compressor module DC connected or connection error. BUS over voltage Compressor module software over current Fan motor module soft- ware over current Current detecting circuit abnormal of compressor module 192","Master unit Indication Failure code Failure description Remarks digital tube on wired controller Compressor Power supply of compressor module DC If it occurs 4 display module power BUS instantaneous interruption. times in an (hex) supply abnor- hour, con- 120-0 mal Power supply of compressor module 78 instantaneous interruption caused by the - 120-1 Compressor module chip reset. ure. Once module power un-resumable 121-0 79 supply abnor- Resistor of temp. sensor abnormal or 121-1 mal temp. sensor disconnected. If it occurs 4 times in an 122-0 7A Radiator temp. Hardware instantaneous over current of hour, con- 122-1 sensor of com- pressor module Compressor module three-phase power - 123-0 7B is abnormal. failure ure. Once 123-1 Hardware un-resumable instantaneous (Current frequency\u2265INV target frequen- 124-0 over current of cy+3Hz) or \uff08target frequency>0 & actual Resumable the compressor frequency=0\uff09for continuous 5 minutes 7C Under 20rpm running for 30s, or 70% of side the target value for 2 minutes, stop, 2 124-1 Compressor minutes and 50 seconds after the auto- module three- matic recovery, if it occurs four times in 125-0 7D phase power 125-1 7D failure 125-4 125-5 Compressor frequency un- match Fan motor speed un- match 126 7E Module Module unknown failure, if it occurs four unknown failure Once If the master unit inspects that MCU of resumable slave unit is reset, and the slave unit is running, the master unit alarm MCU reset 127 7F MCU reset failure, then the whole system stop. In failure heating mode, when restart up, 4WV will will execute 4WV reversing operation again. If it occurs 4 times in one hour, 193","When there is no failure, if the starting condition can not be met, digital tube on master unit will display standby code: 555.1 26\u00b0C heating In heating mode, when the ambient temperature over 26\u00b0C, the system will standby. 555.2 The pressure is too low (lack When the unit starts in cooling with Ps<0.23Mpa of refrigerant) or heating with Ps<0.12Mpa, the system will standby. 555.3 54\u00b0C cooling In cooling mode, when the ambient temperature Resumable 555.5 Power restrain over 54\u00b0C, the system will standby. When setting the maximum capacity output of power restrain is 0%, the system will standby. 555.6 Coded lock restrictions Reach the system maximum operation time set by coded lock, the system will standby 555.8 No trial operation No trial operation, the system will standby \u203bFailure code distribution introduction 0 \uff5e 19\uff1aindoor unit failure 20 \uff5e 99\uff1aoutdoor unit failure 108 \uff5e 125\uff1ainverter module failure 126 \/ 127\uff1asoft self-detect 194","23. Troubleshooting 23.1 Flow chart Failure code LED5 Failure description: Outdoor Defrosting temperature sensors: digital Indoor unit LED status 20 times Tdef failure display tube: 20-0 Outdoor unit LED status LED1 LED2 Troubleshooting Indoor wired Normal controller: Normal Normal 14 Failure diagnosis and troubleshooting 1. Model Diagnosis MRV 5 series 2. Abnormity detection method Check if the corresponding N Replace it correctly by after- connector of sensor is normal sales personnel on site. \u25c6 Check if the sensor connection is normal; Y \u25c6 Check if resistance characteristic of the sensor is normal; \u25c6 Check if the temperature loop acquired by the PCB is normal. conditions Check if resistance N Replace it correctly by after- characteristic of the sensor sales personnel on site. AD value is below 11 (open is normal circuit) or over 1012 (short circuit) for 60 seconds, sensor has no alarm when abnormal in cooling mode. 4. Possible causes \u25c6 The connection of sensor is Y Y Replace it correctly by after- sales personnel on site. not secure; Check if the temperature \u25c6 The sensor is broken; loop acquired by the \u25c6 The sensor is with computer board is normal resistance drift; \u25c6 The temperature acquired by PCB is not accurate. 195","Failure code LED5 Failure description: Outdoor Ambient temperature sensor: digital Indoor unit LED status 20 times Tao failure display tube: Outdoor unit LED status 21 LED1 LED2 Troubleshooting Indoor wired controller: Normal Normal 15 Failure diagnosis and troubleshooting 1. Model Diagnosis MRV 5 series 2. Abnormity detection method Check if the corresponding N Replace it correctly by after- connector of sensor is normal sales personnel on site. \u25c6 Check if the sensor connection is normal; Y N Replace it correctly by after- \u25c6 Check if resistance sales personnel on site. characteristic of the sensor is Check if resistance normal; characteristic of the sensor \u25c6 Check if the temperature is normal loop acquired by the PCB is normal. Y conditions It is detected that the AD value is below 11 (open circuit) or above 1012 (short circuit) for 60 seconds continuously, and no alarm is given during defrosting and within 3 minutes at the end of defrosting. 4. Possible causes \u25c6 The connection of sensor is Check if the temperature Y Replace it correctly by after- loop acquired by the sales personnel on site. not secure; computer board is normal \u25c6 The sensor is broken; \u25c6 The sensor is with resistance drift; \u25c6 The temperature acquired by PCB is not accurate. 196","Failure code Indoor unit LED status LED5 Failure description: Outdoor 20 times Suction temperature sensor: digital Ts failure display tube: Outdoor unit LED status LED1 LED2 22-2 Normal Normal Troubleshooting Indoor wired controller: Failure diagnosis and troubleshooting 16 Diagnosis 1. Model MRV 5 series 2. Abnormity detection method Check if the corresponding N Replace it correctly by after- connector of sensor is normal sales personnel on site. \u25c6 Check if the sensor connection is normal; Y N Replace it correctly by after- \u25c6 Check if resistance sales personnel on site. characteristic of the sensor is Check if resistance normal; characteristic of the sensor Y Replace it correctly by after- \u25c6 Check if the temperature is normal sales personnel on site. loop acquired by the PCB is normal. Y conditions Check if the temperature loop acquired by the It is detected that the AD value computer board is normal is below 11 (open circuit) or above 1012 (short circuit) for 60 seconds continuously, and no alarm is given during defrosting and within 3 minutes at the end of defrosting. 4. Possible causes \u25c6 The connection of sensor is not secure; \u25c6 The sensor is broken; \u25c6 The sensor is with resistance drift; \u25c6 The temperature acquired by PCB is not accurate. 197"]
Search
Read the Text Version
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 76
- 77
- 78
- 79
- 80
- 81
- 82
- 83
- 84
- 85
- 86
- 87
- 88
- 89
- 90
- 91
- 92
- 93
- 94
- 95
- 96
- 97
- 98
- 99
- 100
- 101
- 102
- 103
- 104
- 105
- 106
- 107
- 108
- 109
- 110
- 111
- 112
- 113
- 114
- 115
- 116
- 117
- 118
- 119
- 120
- 121
- 122
- 123
- 124
- 125
- 126
- 127
- 128
- 129
- 130
- 131
- 132
- 133
- 134
- 135
- 136
- 137
- 138
- 139
- 140
- 141
- 142
- 143
- 144
- 145
- 146
- 147
- 148
- 149
- 150
- 151
- 152
- 153
- 154
- 155
- 156
- 157
- 158
- 159
- 160
- 161
- 162
- 163
- 164
- 165
- 166
- 167
- 168
- 169
- 170
- 171
- 172
- 173
- 174
- 175
- 176
- 177
- 178
- 179
- 180
- 181
- 182
- 183
- 184
- 185
- 186
- 187
- 188
- 189
- 190
- 191
- 192
- 193
- 194
- 195
- 196
- 197
- 198
- 199
- 200
- 201
- 202
- 203
- 204
- 205
- 206
- 207
- 208
- 209
- 210
- 211
- 212
- 213
- 214
- 215
- 216
- 217
- 218
- 219
- 220
- 221
- 222
- 223
- 224
- 225
- 226
- 227
- 228
- 229
- 230
- 231
- 232
- 233
- 234
- 235
- 236
- 237
- 238
- 239
- 240
- 241
- 242
- 243
- 244
- 245
- 246
- 247
- 248
- 249
- 250
- 251
- 252
- 253
- 254
- 255
- 256
- 257
- 258
- 259
- 260
- 261
- 262
- 263
- 264
- 265
- 266
- 267
- 268
- 269
- 270
- 271
- 272
- 273
- 274
- 275
- 276
- 277
- 278
- 279
- 280
- 281
- 282
- 283
- 284
- 285
- 286