Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore Parts List - CME2006R

Parts List - CME2006R

Published by Scotsman®LATAM, 2016-06-17 15:51:52

Description: Parts List - CME2006R

Search

Read the Text Version

CME2006R Service PartsThis parts list contains the part numbers and description of the replacment parts available for this model.To avoid costly and time consuming errors, double check the model and voltage before ordering a part. Table of ContentsCabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2Water System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5ERC611 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6BH900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7BH1650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8Kit Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10 July 1998 Page 1

CME2006R Service Parts Cabinet 1 2 17 3 16 21 4 14a 1819 20 14, incl 2314a, 23, 24 24 12 22 713 6 15 9 11ItemNumber Part 12 10 Insul 8 Part 5 21 Number 1 Item A37489-002 Description A37489-001 One piece front panel, grey 2 Number Description Number 03-1735-01 One piece front panel, SS 3 A37201-015 Screw for above panels 4 A37202-015 Top panel, Grey 14 A37201-002 24” Left front panel, grey 5 02-3794-02 24” Left front panel, SS A37202-002 Top panel, SS 03-1731-02 Trim strip 6 A37198-015 Push nut for trim strip 7 02-3823-21 Top panel, plastic for C and A37198-002 Left side panel, grey 8 A37365-001 Left side panel, SS 9 D series. Will not fit A or B series. 15 02-3696-03 Left side channel 10 02-3686-01 Insulation A37216-001 Left grommet 02-3696-02 Bracket 11 A37197-001 Back panel 15a 03-1531-01 Right grommet 12 03-1404-37 Screw A37195-001 Screw 13 15-0808-03 Channel, front top A37199-015 Right side panel, grey 16 15-0792-02 Scotsman emblem A37199-002 Right side panel, SS CM3 emblem A37194-001 Right bottom channel 17 A37213-001 Right side support 18 02-3702-21 Evaporator cover & insulation 19 Cover retainer 02-3701-01 20 24” Right front panel, grey A37200-015 24” Right front panel, SS 21 A37200-002 Emblem 22 15-0790-01 Panel support clip 23 02-3699-01 03-1735-01 Front panel screw 24 April 2004 Page 2

CME2006R Service Parts Water System 1 3Item Part 4 3Number Number 5 02-3613-01 Description 54 6 1 02-3725-01 Elbow 3 7 2 13-0617-48 Hose clamp 2 3 02-3518-01 O-ring 3 4 02-3519-01 1 5 13-0840-01 6 02-2527-01 Manifold 8 7 A37315-021 Manifold right 8 02-3337-02 9 02-3672-01 Plug 10 02-3672-02 11 A37337-001 Water distributor 12 11-0540-21 13 02-3689-01 Evaporator 12 14 02-3706-01 15 Ice deflectorsplash Right trough 10 11 Left trough 13 Evap support 15 Ice sensor (set) 28 32 Ice sensor holder 13 9 Upper inner 35 16 33 9\" 20 34 14 17 29 27 23 19 26 18 30 22 31 25 24 21 22\"16 13-0674-02 Tube, order 1 unit 27 11-0539-51 Water level sensor17 02-3680-01 Lower inner splash panel 28 12-2666-01 Water solenoid valve18 02-3660-01 Water discharge hose 16-0355-00 Coupling half19 11-0515-21 Temp sensor set 29 12-2665-01 Harness for water sensor20 02-3383-06 Float stem 30 02-3388-05 Pump bracket21 13-0674-06 Drain hose, order 2 units 31 12-2582-21 Water pump22 11-0514-01 Purge valve 32 A37204-001 Bracket23 02-3703-01 Drain plug 33 03-1404-18 Screw24 02-3692-21 Drain fitting 34 03-1691-01 Nylon screw25 02-3341-01 Float 35 02-3534-01 Reservoir cover26 02-3388-04 Pump bracket August 2008 Page 3

CME2006R Service Parts Refrigeration 20 2 TXV BULB To Evaporator Outlets 3 BULB MUST BE HELD 8 SECURELY IN PLACE USING 9a 22 in-lbs OF TORQUE OUTLET 1a INLET 9 IN 21 4 To Evaporator Inlets 23 1410 22 1 EVAPORATOR SECTION 20 6 11 5 7 1b To Liquid Line 12Item Part 19 13 24Number Number 18 15 16-1026-01 Discharge Line 1 A37211-001 Description 1a A37212-001 17 1b 16-0850-03 17a 2 16-1029-01 16a 3 16-1030-01 4 16-0850-01 Receiver 16 5 16-1028-01 6 12-2471-22 Top receiver bracket 14 11-0501-22 Hi pressure cut out 7 16-1063-01 7a 16-1055-01 Bottom receiver bracket 15 16-0832-20 Suction access valve 8 16-1054-22 16-0832-03 Port cap 9 A37402-001 Liquid line fitting 16-0832-02 Stem cap 9a 11-0507-23 03-1729-01 Solid Mount 10 12-2719-23 Liquid line check valve 16 03-1729-03 Rubber pad 16-1063-03 Liquid line acess valve 16a 03-3843-01 Rubber grommet 10a A37405-001 Discharge line fitting 03-1405-20 Bolt 11 16-1041-21 Discharge check valve 17 18-2300-26 Sleeve for rubber grommet 12 02-3396-01 03-1729-02 Washer for solid mount 11-0515-21 Harvest bypass valve 17a 03-1407-07 Washer for rubber grommet 13 Strainer for bypass valve Suction manifold 18 18-8821-21 Compressor, 60 Hz, single phase 18-8821-22 Compressor, 60 Hz, 3 phase Accumulator w/insul. 18-8828-01 crankcase heater for 3 phase Replacement compressors include a dryer Accumulator support 02-3319-02 Dryer Hot gas valve w/coil 19 03-1406-13 Nut 20 Hot gas valve coil only 21 03-1406-12 Nut 22 Strainer for HGV 23 A37315-021 Evaporator 24 Distributor and tubes 16-1050-01 Hot gas header TXV, AAE 2 5Z 11-0502-21 Low pressure cut out Insulation for TXV Temp sensor set August 2006 Page 4

CME2006R Service Parts Electrical 1 PH ONLY 13a 9 13 11 2 3 10 1 PH ONLY 24 7 8 64 1 PH ONLY 1 2 12 3 PH 14 ONLY 1524V (3/16)TOWARD 4FRONT OFMACHINE 4 5 4 1 PH ONLYItem Part Item PartNumber Number A37217-001 Description Number Number Description 1 12-1213-11 Transformer Bin thermo harness 2 12-1213-10 Snap bushing 14 12-2701-01 Bin thermostat 3 03-1531-01 Snap bushing 4 18-1903-55 Screw 15 11-0521-21 Thermostat bracket 5 18-1902-59 60 Hz potential relay 3 pronged knob 6 18-1901-58 Run capacitor Not Shown: Lo voltage harness 7 A37366-001 60 Hz start capacitor Hi voltage harness 8 12-2838-23 Strap 02-3740-01 9 12-2595-01 Controller 10 11-0531-22 Single phase contactor 03-1675-03 11 12-2533-01 Purge valve timer 12 11-0530-01 3 phase contactor 12-2663-02 13 03-1531-10 Time delay relay 13a Screw 12-2732-01 April 2004 Page 5

CME2006R Service Parts ERC611 Remote Condenser 1 2 4 3 5Item Part DescriptionNumber Number Screw 03-1405-08 Fan guard 1 02-3770-01 Headmaster 2 16-1044-01 Fan blade 3 18-8820-01 Fan motor 4 12-2717-01 5Not Shown: Leg A37169-001 Leg brace A37296-001 Screw for legs 03-1645-01 Quick connect, discharge 16-0850-01 Quick connect, liquid 16-0850-03 July 1998 Page 6

CME2006R Service Parts 1 2 BH900 Ice Storage Bin 3 4 22 21a 21b 10 21 5 12 9 1113 14 8 15 16 19 18 17 720 6ITEM PARTS 13 03-1539-09 “E” ring 14 02-2380-01 Hinge bushingNUMBER NUMBER DESCRIPTION 15 02-3195-01 Door hinge 1 A35322-020 Canopy Assembly 16 02-3196-01 Bin hinge 2 A35152-001 Ice Baffle 17 02-2806-01 Shoulder screw 3 02-2809-01 Drain Top 18 02-2380-02 Spacer 4 13-0617-11 O-ring 19 03-1403-29 Screw 10-24 5 02-3201-01 Drain casting 20 03-1403-24 Screw 10-24 6 KLP2E Leg Kit, Black 21 A35280-001 Left bin channel KLB2S Leg kit, nickel plated 21a A35311-001 Back bin channel 7 15-0711-01 Emblem 21b A35279-001 Right bin channel 8 13-0595-00 Door gasket (order qty 7) 22 02-3202-01 Trim guard 9 19-0503-04 Bin gasket (order by foot) BH900CE or CS used a different door, hinge & pin: 10 03-0727-11 Baffle screw 12 02-3222-01 Door 11 A35275-001 Door frame assy. A37641-021 Frame, for BH900S-C 02-3225-01 Hinge kit 12 A35323-020 Door with gasket - BH900 02-3226-01 Pivot pin set April 2004 Page 7

CME2006R Service Parts BH1650 Ice Storage Bin “Z” Brackets are used when 1attaching CME1356 or CME1656 2 to bin. Attaching screw pn: 34 03-1645-01 5 Gasket: 02-3769-17, 6 order number of feet needed 7 16 11 8 15 10 9 13 12 14Item Part Description 10 02-3769-14 Plugs for end plateNumber Number Track 11 02-3769-10 Catch for ice gate 02-3769-02 Window 12 02-3769-15 Ice gate retainer 1 02-3769-16 Lower frame assembly 13 02-3769-06 Left hinge 2 02-3769-04 Left and right hinges 14 02-3769-01 Plastic drain 3 02-3769-08 Door with door hinges 15 KLP2S Legs 4 02-3769-05 Right hinge Not Illustrated: 5 02-3769-07 Ice gate Probe tool 6 02-3769-09 End plate guide (pair) 02-3769-18 Plastic Ice shovel. 7 02-3769-12 Screws for end plate 02-3769-19 Z brackets 8 02-3769-13 02-3775-01 9 July 1998 Page 8

CME2006R Service Parts Kit PartsStacking Kit - KSCME6-LG-B A37935-001 Left Cutain Right CurtainHarness 12-2699-01 02-3885-01 July 2002 Page 9

CME2006R Service Parts Single Phase Wiring Diagram17-2633-01 USE COPPER CONDUCTORS ONLY 1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL O CODE AND ALL STATE AND LOCAL CODES. O 2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK WATER MOT HARVEST BYPASS HOT GAS WIRE COLOR FOR 230/50/1 UNITS : BROWN SOLENOID PUMP SOLENOID R W/R SOLENOID BN O W/BU LOAD O DUMP BU O VALVE BU LINE B/W W TRANSFORMER T2 BU THERMO V BU O T1 T3 BIN R O L1 T1 BK/W TIME OFF(OPTIONAL) V CONTACTOR BU DELAY RELAY Y SUMP TEMP. L2 T2 POTENTIAL RELAY DUMP SENSOR 51 VALVE RELAY DISCHARGE 2 TEMP. SENSOR BK BIN FULL TRANSMITTER Y/W Y RUN 1234567 1234 CAP 8 9 BN 7 R/W 6 W/R START Y CAP 12 3 1 2 3 4 5 1 2 3 1 2 3 1 2 3 4 5 5 LOW PRESSURE CONTROL BK BK ELECTRONIC CONTROL Y 4 3BIN FULLRECEIVER 2 HIGH PRESSURE 2 BK Y R CONTROL 2 CRANKCASE HEATER 1 COMMUNICATIONS BU BU T2 PORT PROTECTOR S INTERNAL TERMINAL BOX JUNCTION T1 BOX WATER THIS UNIT MUST GROUND C LEVEL BE GROUNDED. SCREW T3 SENSOR R 1 EARTH GROUND 1CAUTION: 1 COMPRESSORMORE THAN ONE DISCONNECT MEANS MAY BE POWER SUPPLY FANREQUIRED TO DISCONNECT ALL POWER TO THIS UNIT. REMOTE CONDENSER SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE July 1998 Page 10

CME2006R Service PartsSingle Phase Schematic Diagram L1 L2 CRANKCASE HEATER LINE TRANSFORMER 24V DUMP VALVE RELAY TRIGGER HOT GAS VALVE WATER VALVE TIME OFF DELAY RELAY LOW HIGH CONTACTOR PRESS. PRESS. COIL CONT. CONT. BIN STAT HARVEST BYPASS(OPTIONAL) SOLENOID ELECTRONIC CONTROL SUMP BIN BIN WATER TEMP. FULL FULL LEVEL X-MIT RCV. SENSORDISCHARGETEMP.DUMP VALVE RELAY WATERCONTACTS PUMP DUMP VALVECONTACTOR T1POTENTIAL POTENTIAL STARTRELAY COIL RELAY CAP. RUN CAP. COMPRESSOR REMOTE CONDENSER FAN July 1998 Page 11

CME2006R Service Parts Three Phase Wiring Diagram17-2626-01 USE COPPER CONDUCTORS ONLY WATER MOT HARVEST BYPASS O HOT GAS 1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE SOLENOID PUMP SOLENOID O SOLENOID INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES. BU R W/R BN O LOAD DUMP BU W/BU VALVE O B/W LINE BU V TRANSFORMER DUMP VALVE W RELAY BU R BK/W O L1 L2 L3 V T1 T2 T3 Y THERMO BIN BK(OPTIONAL) SUMP TEMP. 1234567 1234 LOW PRESSURE SENSOR 8 9 CONTROL DISCHARGE 7 Y TEMP. SENSOR 6 BIN FULL 12 3 1 2 3 4 5 1 2 3 1 2 3 1 2 3 4 5 Y TRANSMITTER 5 BK BK HIGH PRESSURE ELECTRONIC CONTROL CONTROL 4 BIN FULL 3 TERMINAL BOX RECEIVER 2 CRANKCASE HEATER L3 L2 L1 PROTECTOR BK Y R R Y BK BU BU TI C T2 1 COMMUNICATIONS INTERNAL T3 S PORT JUNCTION R BOX WATER LEVEL GROUND SENSOR THIS UNIT MUST SCREW BE GROUNDED. EARTH GROUND 1 1CAUTION: 1 FAN COMPRESSOR 1 REMOTE CONDENSERMORE THAN ONE DISCONNECT MEANS MAY BE POWER SUPPLYREQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE July 1998 Page 12

CME2006R Service PartsThree Phase Schematic DiagramL1 L2 L3 LINE TRANSFORMER 24V DUMP VALVE RELAY TRIGGER HOT GAS VALVE WATER VALVE LOW HIGH CONTACTOR PRESS. PRESS. COIL CONT. BIN CONT. STAT HARVEST(OPTIONAL) BYPASS SOLENOID CRANKCASE HEATER ELECTRONIC CONTROL SUMP BIN BIN WATER TEMP. FULL FULL LEVEL X-MIT RCV. SENSORDISCHARGETEMP.DUMP VALVE RELAYCONTACTS DUMP VALVE WATER PUMPCONTACTOR T1 T2 T3 COMPRESSOR REMOTE CONDENSER FAN July 1998 Page 13

Bulletin Number: PS - 4 - 2004 Bulletin Date: April 2004SERVICE BULLETINSubject: Controller CoverAffects all versions of models: CME1356, CME1656, CME1856 and CME2006The above models are now manufactured with a sheet metal cover over the top of the controller.Service controllers also are now shipped with a cover that should be applied to these modelswhenever replacing the controller if the machine does not already have a cover installed.Whenever cleaning or servicing any unit, check to see whether it has a cover over the controller likethe one shown below. If it does not, Scotsman recommends installing a cover. A separate part isnow available for this purpose. Its part number is A37480-021. It mounts over the top end of thecontroller and is secured by two sheet metal screws. Use the cover as a template and drill two 1/8”holes for the two screws.Controller Cover Cover Installed on UnitScotsman is shipping a supply of covers to all Scotsman Distributors and listed service agencies. Asupply of covers should be carried by each service person on service calls so a cover may beinstalled on the unit being cleaned or serviced if one is not already in place. Additional covers maybe obtained free of charge from Scotsman, through the local Scotsman Distributor, as needed.


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook