Tel/Tel: 450-444-7414             TF/SF: 1-800-724-6600                 Fax: 450-444-7074   www.rampart.ca | [email protected] rue lndustrielle, La Prairie, Qc J5R 2E4
Page 2 of 33                ACOUSTIC PANEL SYSTEMS                                  Table of Contents WALL PANEL SYSTEM TYPES     Section 1. RA 1: Standard Acoustical Panels            I. Description            II. Options            III. Specifications     Section 2. RA 2: Impact Resistant Panels            I. Description            II. Options            III. Specifications     Section 3. RA 3: High Impact Resistant Panels            I. Description            II. Options            III. Specifications     Section 4. RA 4: Tackable Panels            I. Description            II. Options            III. Specifications     Section 5. RA 5: Reflective Panels            I. Description            II. Options            III. Specifications     Section 6. RA 6: Acoustical Panels with Wood Battens            I. Description            II. Options            III. Specifications1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 3 of 33PANEL INSTALLATION AND OPTIONS   Section 7. Panel installation methods          I. ‘Z’ clip and track          II. Velcro   Section 8. Corners and Build-Ups          I. Preformed corners details          II. Edge build-up details    Section 9. Edges, Corners and Frames          I. Wall panel edge profile          II. Corners          III. Hardened edges   Section 10. Curved Applications          I. Concave and convex panels    CEILING PANEL, SYSTEM TYPES   Section 11. RAB 1: Ceiling Baffles          I. Description          II. Options          III. Specifications          IV. Special Applications                  i. In Between Beams - Angled Suspension                  ii. Multiple Layered Baffles                 iii. Directional Baffles   Section 12. RAC 1: Exposed Grid          I. Description          II. Specifications   Section 13. RAC 3: Oversize Panels          I. Description          II. Specifications1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 4 of 33 GENERAL INFORMATION FOR WALL PANELS AND CEILING SYSTEMS     Section 14. Limitations     Section 15. Maintenance     Section 16. Sound Tests            I. Sound Test 1            II. Sound Test 2            III. Sound Test 3            IV. Sound Test 41305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 5 of 33Section 1. RA-1 Standard Acoustical Panel       I. Description                                               RA-1: Standard Acoustic Wall Panel                                               It is the most versatile and economical model. Especially                                               designed to reduce noise reflected from rigid surfaces such as                                               gyprock or concrete -can change completely reflective wall into                                               a highly absorptive one. Suited for almost any area where noise                                               must be controlled or eliminated. Applications: the open office,                                               conference room, library, auditorium, broadcast or recording                                               studio.Sectional view of                              6 lb./ft.3 (96 kg/m3) fiberglass RA-1 wall panel                               1” (25 mm) thick fiberglass                                               Untreated edgeFiberglass                                     No attachment (adhesive by others)                                               Polyester or perforated vinyl finish (specify)Finish Material                    Options     Square corner and edge                                               Field measured sizes up to 4 ft. x 8 ft. (1,2        II.                                    m x 2,4 m) and 4 ft. x 10 ft. (1,2 m x 3m)Options available for RA-1                     Thicker fiberglass: 3/4”, 1-1/2”, 2” (19 mm,                  wall panel                   38 mm , 51 mm) or other combination                                               (Contact factory for more information)   Special Shaped Edges                        Hardened edges or wood or metal frames                 (see page 17)                 (page 17)                                               Z-clips and tracks and/or Velcro (page 15)             Hardened Edges                    Almost any fabric or vinyl (Check with                 (see page 17)                 factory prior to specifying)               Attachments                     Plywood or foil backing                                )              Custom corner and edge (page 17)                                               Preformed corner (page 16)             Edge Build-up                     Oversize panels (page 18)                 (see page 16)                 Curved panels (page 18)                                                                    see page 25 for limitations        NOISE REDUCTION COEFFICIENTS : C.423, TYPE A MOUNTING **Test 1 2 3 4Panel                              1” (25 mm)  2” (51 mm)           _“ (19 mm)     1” (25 mm)                                   fiberglass  fiberglass           fiberglass     fiberglassFinish                             Micro-perl, vinyl Fabric finish  Fabric finish  Fabric finishNRC rating 0.70 1.15 0.70 0.80                                               *see page 27 to 30 for Sound Absorption Test results **Modified1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 6 of 33            III. Specifications  Construction  The core shall be Class A incombustible, dimensionally stable, 6 lb/ft.3 (96 kg/m3) fiberglass  and have a sufficient thickness to provide an NRC over 0.70 to 1.15 when tested in  accordance with ASTM C423.  Concealed Edges: The edge of the core shall be hardened.  Attachments:          Z-Clips: These shall be bonded to a reinforced area at the back and continuous Z-          track made of galvanized steel or aluminum and spaced as recommended by          Rampart Partitions Inc.  or          Velcro: Shall be factory bonded to a reinforced area an be sufficient size and          quantities to assure positive adhesion.  or          Adhesive: The panels shall be fixed with an acoustical adhesive (supplied by the          contractor). The adhesive spots shall be within the maximum spacing as          recommended by Rampart Partitions Inc.  Exposed Edges & Corners: Panel exposed edges and corners as shown on the drawings.  (See section 9)  Finish          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.  or          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions  The dimensions shown on the drawings and finishes schedule are for biddingpurposes  only. The panels must be factory supplied to field measured dimensions and  be within 1/16” (1,6 mm).  Sample and Test Results  An 8“ x 10” (203 mm x 254 mm) sample and test results must be approved by the architect  prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 7 of 33Section 2. RA-2 Low Impact Resistant Panel       I. Description                                    RA-2: Low Impact Resistant Panel                                    This model is designed to withstand surface damage cause                                    by impact, by laminating a protective scrim to the surface                                    beneath the finish. Applications: hallways, schools, churches,                                    concert halls and non-acoustical furniture.Sectional view of      The yellow jacket allows for a smoother fabric application where RA-2 wall panel       light conditions are critical, such as down lights or shiny fabrics.         Fiberglass                      6 lb./ft.3 (96 kg/m3) fiberglass     Yellow Jacket                       1” (25 mm) thick fiberglass                                         Untreated edge    Finish Material                      No attachment (adhesive by others)                                         Polyester or perforated vinyl finish (specify)                                         Square corner and edge                                         Field measured sizes up to 4 ft. x 8 ft. (1,2                                       m x 2,4 m) and ft. x 10 ft. (1,2 m x 3 m)       II. Options         Thicker fiberglass:3/4”, 1-1/2”, 2” (19 mm,                           38 mm , 51 mm) or other combination.Options available forRA-2wall panel              (Contact factory for complete information)Special Shaped Edges       Hardened edges or wood or metal frames(see page 17)Hardened Edges              (page 17)(see page 17)Attachments                Z-clips and tracks and/or Velcro (page 15))                          Almost any fabric or vinyl (Check with factoryEdge Build-up(see page 16)               prior to specifying)                           Plywood or foil backing                           Custom corner and edge (page 17)                           Preformed corner (page 16)                           Oversize panels (page 23)                           Curved panels (page 18)                       see page 25 for limitations1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 8 of 33            III. Specifications  Construction  The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)  fiberglass with a ¨yellow jacket¨ laminated to its face and have an overall thickness of 3/4”,  1“ or 2” (19 mm, 25 mm or 51 mm).  Concealed Edges: The edge of the core shall be hardened)  Attachments:          Z-Clips: These shall be bonded to a reinforced area at the back and continuous Z-          track made of galvanized steel or aluminum and spaced as recommended by          Rampart Partitions Inc.  or          Velcro: be factory bonded to a reinforced area an be sufficient size and quantities          to assure positive adhesion.  or          Adhesive: The panels shall be fixed with an acoustical adhesive (supplied by the          contractor). The adhesive spots shall be within the maximum spacing as          recommended by Rampart Partitions Inc.  Exposed Edges & Corners: Panel exposed edges and corners as shown on the drawings.  (see page 17)  Finish          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.  Or          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2“(38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1,6 mm).  Sample and Test Results:  An 8“ x 10” (203 mm x 254 mm) sample and test results must be approved by the architect  prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 9 of 33Section 3. RA-3 High Impact Resistant Panel       I. Description                                 RA-3: High Impact Resistant Panel                                 Specially designed for high circulation areas and industrial                                 installations where risk of surface damage is greatest such as                                 hotel lobbies, transportation terminals, retail outlets and                                  restaurant.Sectional view of               Ideal for applications where the panels are subjected to mild RA-3 wall panel                blows, as such as corridors or gymnasiums.         Fiberglass                          6 lb./ft.3 (96 kg/m3) fiberglass                                             1” (25 mm) thick fiberglass          Glastrate                          High density 1/8” (3 mm) thick glastrate         (bonded to                          Untreated edge         fiberglass)                         No attachment (adhesive by others)                                             Polyester or perforated vinyl finish (specify)    Bonded Finish                            Square corner and edge            Material                         Field measured sizes up to 4 ft. x 8 ft. (1,2 m x                                             2,4 m) and 4ft. x 10 ft. (1,2 m x 3 m)          II.          OptionsOptions available for           Thicker fiberglass: 1“, 1-1/2”, 2” (25 mm, 38RA-3 wall panel                 mm, 51 mm) or other combination (ContactSpecial Shaped Edges            factory.)(see page 17)Hardened Edges                  Hardened edges or wood or metal frames(see page 17)Attachments                     (page 17))Edge Build-up                   Z-clips and tracks and/or Velcro (page 15)(see page 16)                                Almost any fabric or vinyl (Check with factory                                prior to specifying)                                Plywood or foil backing                                Custom corner and edge (page 17)                                Preformed corner (page 16)                                Oversize panels (page 23)                                Curved panels (page 18)1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 10 of 33            III. Specifications  Construction:  The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)  fiberglass and 18 lb./ft.3 (288 kg/m3) glastrate on the full face and have an overall thickness  of 7/8“, 1-3/16” or 2-3/16” (22 mm, 30 mm or 56 mm).  Concealed Edges: The edge of the core shall be hardened.          Attachments:          Z-Clips: These shall be bonded to a reinforced area at the back and continuous Z-          track made of galvanized steel or aluminum and spaced as recommended by          Rampart Partitions Inc.or          Velcro: Shall be factory bonded to a reinforced area an be sufficient size and          quantities to assure positive adhesion.or          Adhesive: The panels shall be fixed with an acoustical adhesive (supplied by the          contractor). The adhesive spots shall be within the maximum spacing as          recommended by Rampart Partitions Inc.  Exposed Edges & Corners: Panel exposed edges and corners as shown on the drawings.  (see page 17)  Finish:          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.  or          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1, 6 mm).  Sample and Test Results:  An 8“ x 10” (203 mm x 254 mm) sample and test results must be approved by the architect  prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 11 of 33Section 4. RA-4 Tackable Panel       I. Description:                                  RA-4: Tackable Panel                                 Rampart tackable panels can be used as a small track board                                 beside a desk or as a complete tackable wall. They can be                                 combined with other panel models to provide continuity where                                 sound absorption is required. Installations would include                                 architect’s and designer’s offices, classrooms, halls,                                 boardrooms and many other applications.Sectional view of RA-4 wall panel                              Can be added onto walls or office systems. Adds a touch of colorMineral Board                                                  and offers excellent tackability.                                                                     1/2” (13 mm) thick mineral board                                                                     Untreated edge                                                                     No attachment (adhesive by others)                                                                     Polyester fabric                                                                     Square corner and edge                                                                     Dimension up to 4 ft. x 8 ft. (1,2 m x 2,4 m)                                    Bonded Finish Material     Note: Rampart also manufactures a complete range of                                                               free-standing workstations. Contact us for more information.              II. Options:                                                                        Thickness varying from 1/2” to 2” (6 mm, 51Sectional view of RA-4 wall panel                                       mm)                                               Velcro                   Magnetic mounting for sides of filling cabinet                                                                        Designed edge and corner (can be limited by                                          attachment                                                            )             thickness page 16)                                                                        100% Polyester fabric finish (vinyl not                                                                          recommended for tack board)                                                                        Z-clips and tracks –over 1” thick only                                                                        Preformed corner (page 16)                                                                        Oversize panels (page 23)                                                                        Hook and loop mounting (Velcro)                                                                        Other thicknesses and construction available                                                                        Special build-ups to fit particular applications1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 12 of 33            III. Specifications:  Construction:  The core shall be Class A incombustible, dimensionally stable, mineral board and have an  overall thickness of 1/2” (13 mm).  Attachments:          Z-Clips: These shall be bonded to a reinforced area at the back and continuous Z-          track (on panel over 1” thick) made of galvanized steel or aluminum and spaced as          recommended by Rampart Partitions Inc.  or          Velcro: Shall be factory bonded to a reinforced area an be sufficient size and          quantities to assure positive adhesion. )  or          Adhesive: The panels shall be fixed with an acoustical adhesive (supplied by the          contractor). The adhesive spots shall be within the maximum spacing as          recommended by Rampart Partitions Inc.  Exposed Edges & Corners: Panel exposed edges and corners as shown on the drawings.  (see page 17)  Finish:          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1,6 mm).  Sample and Test Results:  An 8“ x 10” (203 mm x 254 mm) sample and test results must be approved by the  architect prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 13 of 33Section 5. RA-5 Reflective Panel          I. Description               Ideal for high absorption of low frequencies for applications such                                       as the front of auditorium or sound studios.Sectional view of RA-5wall panelFiberglass                             6 lb./ft.3 (96 kg/m3) fiberglassBonded                                 1” (25 mm) thick fiberglass                                       Untreated edgeAluminum Foil                          No attachment (adhesive by others)                                       Polyester or perforated vinyl finish (specify)Finish                                 Square corner and edgeMaterial                               Dimensions up to 4 ft. x 8 ft. (1,2 m x 2,4 m)                                       and 4 ft. x 10 ft. (1,2 m x 3 m)                       II. Options     Ideal for high absorption of low frequencies for applications such                                       as the front of auditorium or sound studios.Options available forRA-5 wall panel                                  Thicker fiberglass : 3/4”, 1-1/2”, 2” (25 mm,                                                 38 mm , 51 mm) or other combinationSpecial Shaped Edges                             Hardened edges or wood or metal frames                          Attachments               (section 10)                       Hardened Edges                        Edge Build-up            Z-clips and tracks and/or Velcro                                                 Almost any fabric or vinyl (Check with factory                                                    prior to specifying)                                                 Plywood or foil backing                                                 Custom corner and edge                                                 Preformed corner                                                 Oversize panels                                                 Curved panels1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 14 of 33            III. Specifications:  Construction:  The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg /m3)  fiberglass and laminated aluminum foil. The assembly should be 3/4”, 1” or 2” (19 mm, 25  mm or 51 mm) thick.  Concealed Edges: The edge of the core shall be hardened.  Attachments:          Z-Clips: These shall be bonded to a reinforced area at the back and continuous Z-          track made of galvanized steel or aluminum and spaced as recommended by          Rampart Partitions Inc.  or          Velcro: Shall be factory bonded to a reinforced area an be sufficient size and          quantities to assure positive adhesion.  or          Adhesive: The panels shall be fixed with an acoustical adhesive (supplied by the          contractor). The adhesive spots shall be within the maximum spacing as          recommended by Rampart Partitions Inc.  Exposed Edges & Corners: Panel exposed edges and corners as shown on the drawings.  (see page 17)  Finish:          Vinyl: Panel exposed edges and corners as shown on the drawings. (see page 10)          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1,6 mm).  Sample and Test Results:  An 8“ x 10” (203 mm x 254 mm) sample and test results must be approved by the  architect prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 15 of 33Section 6. RA-6 Acoustic Panel with Wood Batten       I. Description                                                         Ideal for theaters where both a high sound absorption and                                                         impact resistance is required.                                                     6 lb./ft.3 (96 kg/m3) fiberglass                                                     1” (25 mm) thick fiberglass                                                     Untreated edge                                                     No attachment (adhesive by others)                                                     Polyester or perforated vinyl finish (specify)                                                     Square corner and edge                                                     Dimensions up to 4 ft. x 8 ft. (1,2 m x 2,4 m) and                                                     4 ft. x 10 ft. (1,2 m x 3 m)        II. Options                        Ideal for theaters where both a high sound absorption and                                           impact resistance is required.        Batten design options                                                 Almost any fabric or vinyl (Check with factory prior to        1” 1”                  1”  1-1/2”                                                   specifying)3/4”to                                               Plywood or foil backing1-1/2”                                           Designed corner and edge                                                 Field measured sizes and modules        AB                     C   D             Other hardwood and batten designs                                                 Preformed corner                                                 Curved panels1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 16 of 33         III. Specifications:Construction:The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3) thickfiberglass. The edges shall be hardened and squared. The panels shall be mounted fromthe back on continuous Z-tracks spaced as recommended by Rampart.Finish:The core shall be finished on the face, sides and returns with a fully and evenlylaminated Class A incombustible Fabric or Vinyl to be selected from Rampart’s currentcolorchart. Rampart type  Oak or Maple battens to be mechanically attached from theback and spaced      inches (  mm.) o.c.The battens shall:        1. Receive one coat clear varnish or;        2. Receive a fire retardant* clear finish .Dimensions:The dimensions shown on the drawings and finishes schedule are for biddingpurposes only. The panels must be factory supplied to field measured dimensions and bewithin 1/16” (1,6 mm).Sample and Test Results:An 8“ x 10” (203 mm x 254 mm.) sample and test results must be approved by the architectprior to ordering.*Note that fire retardant finishes will slightly change the color of the wood.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 17 of 33Section 7. Panel Installation and options:       I. Z Clip & Track            5/16” (8 mm)  Galvanized or aluminum clip and track                          Optional aluminum clip and track are also available                          Factory mounted on fiberglass or mineral board                          Note: 1” (25 mm) and clearance at the top is required to raise and                          lower the clips onto the tracks.II. Velcro            1/8” (3mm)                          Factory mounted on panel                          ¨Hook¨ part comes with peel-off self adhesive                          Note : Before applying the self-adhesive \"male\", make sure that the                          wall is clean. Rub the self-adhesive \"male” strip to the wall firmly                          before affixing the panels. Avoid unpainted gypsum.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 18 of 33Section 8. Corners & Builds-Ups       I. Preformed Corners                                              Custom made to field measured dimensions                                              Ideal for applications around square                                              columns or outside corners                                              Avoids separation at corners                                              Available for adhesive, Velcro or Z-clip and                                              track mountingII. Edge Build-Up                             In certain conditions it might be possible to notice                                              the gap between the back of the panel and the                            Edge Build-up     wall                            (fabric wrapped)                                              It is possible to have this void filled by a factory                                              applied, fabric wrapped or edge build-up1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 19 of 33Section 9. Edges, Corners & Frames                I. Wall Panel Edge ProfileAB              CDE                                            Other edges can be designed to meet your                                            requirements                             Note: All of these edge profiles require hardening                II. CornersRadius as       Champfered            Where design criteria require a metal frameyour                                  Welded corners availablespecifications                        Other designs availableRadius                       Note: All of these edge profiles require hardening                III. Hardened Edges                                                        Allows greater flexibility in special edge design and                                                        abuse resistant framing                                                                 42 hardness on Barcol scale                                                                 1/8” (3mm) penetration into the fiberglass1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 20 of 33Section 10. Curved Applications       I. Convex And Concave Panels                                                                                         Z-clips                                                            Embedded                                                            Support                                                            ChannelMade to your field dimensionsConcave or convex panelsAvailable for 3/4”, 1”, 1-1/2”, 2” (19 mm, 25 mm, 38 mm, 51 mm) thickpanels. (Consult your factory representative for thicker panels)Factory mounted attachments and special systems availableVinyl or fabric finishMinimum radius for 3/4” (19 mm) and 1” (25 mm) panels: 24” (610 mm)Minimum radius for 1-1/2” and 2” panels: 36” (914 mm)1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 21 of 33Section 11. RAB-1 Ceiling Baffles       I. Description                                  RAB-1: Standard Ceiling Baffles                                  Can be suspended from various ceiling systems to provide                                  added reflective sound control, enhance the surrounding and                                  colour coordinate various sections of an open area. A foil                                  septum can be added to give a degree of sound alternation.                                  Applications: all indoor open areas such as offices, industrial,                                  commercial, school and other installations.D ring suspension                           Ideal for open spaces such as offices                                            Combine different colors and sizes to         Seamless bottom                                                    6 lb./ft.3 (96 kg/m3) fiberg       II. Options                                  1-1/2” (38mm) thick fiberg                                                    3/4” (19 mm) sheetsD ring suspension                                   Untreated edge                                                    D rings or embedded sus                           Aluminum septum          weight         Seamless bottom                            Continuous seamless bot                                                    Square corner and edge                                                    Field measured sizes up                                                    m) and 4 ft. x 10 ft. (1,2 m                                                    Combinations of two fiber                                                    and 2” (25 mm, 38 mm, 5                                                       representative for complete info                                                    Hardened edge                                                    Special corner and edge                                                    Aluminium septum                                                    Almost any fabric or vinyl                                                    Oversize available (Contac                                                    Curved panels to specifie                                                       circular applications)1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 22 of 33            III. Specifications:  Construction:  The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)  fibreglass and have an overall thickness of 1-1/2” or 2” and be suspended from factory  installed eyelet.          Septum: An aluminum septum shall be laminated to the mid-page of the sandwich.          Concealed Edges: The edges of the core shall be hardened.  Finish:          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1,6 mm).  Sample and Test Results:  An 8” x 10” (203 mm x 254 mm) sample and test results must be approved by the  architect prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 23 of 33         IV. Special Applications                i. In Between Beams - Angled Suspension                                   Angled suspension for location in between beams                                             Made to your specified sizes                                        (Contact your local representative for complete information)         ii. Multiple Layered Baffles                                                   Factory made to your dimensions and design                                                   Color combination possible                                                   Different layout to create chandelier effect         iii. Directional Baffles         Color B                                   Ideal for airports, corridors, with one color going in one                                   direction and another color going in the other direction.Color A1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 24 of 33     Section 12. RAC-1 Exposed Grid            I. Descriptions:                                             RAC-1: Highly Sound Absorbing Ceiling Panel                                             Of similar construction as RA-1 wall panel, it provides                                             excellent sound insulation along with an elegant fabric-                                             covered or perforated vinyl ceiling finish without exposed                                             hardware. Applications: For professional and executive                                             office, boardrooms and concert halls –wherever efficient                                             sound control and elegant design is required.                                                        Rampart will custom make ceiling panels to your specifications,                                                        sizes and design using exposed grid                                                        (by others).                                                      3/4” (19 mm) or 6 lb./ft.3 (96 kg/m3)                                                      Vinyl finish (Not returned on edges)                                                      Maximum size up to 2 ft. x 4 ft. (0,6 m x 1,2 m)                                                      Untreated edge (see page 17)1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 25 of 33            II. Specifications:  Construction:  The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)  fiberglass and have a thickness of 3/4”, 1” or 2” (19, 25 or 51 mm) and be supported by an  exposed grid system (by other).  Concealed Edges: The edges of the core shall be hardened and be as shown  on the drawings.  Finish:          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.  or          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1,6 mm).  Sample and Test Results:  An 8” x 10” (203 mm x 254 mm) sample and test results must be approved by the architect  prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 26 of 33Section 13. RAC-3 Oversized Panels       I. Description                                                          Designed for theatres and auditoriums where absorption                                                          and reverberation are critical.SIDE                                                                                           Min. 6”   Factory embedded suspension                                 variesFACE                                Absorptive or reflective face          Vinyl or fabric finishes          Factory mounted built-in suspension          Reflective or absorptive surfaces available. Aluminum foil faced core is ideal to          absorb low frequencies          Curved designs available          The only true limitation of these panels is the fabric or vinyl width and even then          the panels can be made from two smaller onesNote: distances of suspensions from edges are critical.Please consult your local representative.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 27 of 33            II. Specifications  Construction:          The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)          3/4”, 1” or 2” (19, 25 or 51 mm) fiberglass and supported with a factory embedded          galvanized steel or aluminum suspension spaced as recommended by Rampart.  or          The core shall be Class A incombustible, dimensionally stable, 6 lb./ft.3 (96 kg/m3)          3/4”, 1” or 2” (19, 25 or 51 mm) fiberglass and supported with a factory embedded          galvanized steel or aluminum suspension and have an aluminum foil laminated on          the exposed side of the fiberglass.  Edges:  The edges of the core shall be hardened and as shown on the drawings.  Finish:          Vinyl: Micro-perforated Class A incombustible, color to be selected from the current          Rampart standard chart.  or          Polyester Fabric: Class A incombustible, color(s) to be selected from the current          Rampart standard chart. The material shall be laminated, evenly, on the full face, all          sides and on the return on the back, at least 1-1/2” (38 mm).  Dimensions:  The dimensions shown on the drawings and finishes schedule are for bidding purposes  only. The panels must be factory supplied to field measured dimensions and be within 1/16”  (1, 6 mm).  Sample and Test Results:  An 8” x 10” (203 mm x 254 mm) sample and test results must be approved by the  architect prior to ordering.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 28 of 33Section 14. Panel Limitations1. Rampart acoustical panels are manufactured within ± 1/16” (1,5 mm) tolerance and, could    accumulate with each panel. If this is not acceptable, Rampart manufactures field adjusted    panels that can be adapted to your job site conditions. Mention in you specifications that    the last panels should be \"field cut\".2. Fiberglass is a porous material and although Rampart panels are machines and hand    sanded, certain lighting conditions and/or finishing materials will emphasize the natural    waviness of the fiberglass. Be particularly wary of down-lights close to walls, shiny vinyl    and applications near windows. For these conditions, only glastrate panels, such as RA 3,    should be used. Consult us or your local representative.3. Since the thickness of fiberglass cannot be       Fiberglass of    absolutely maintained, Rampart will not supply   3” to 4” longer than    square edge panels with concealed suspension     required & cut to    systems in ceiling applications. (RAC 3)         size in field4. Special fabrics can be used but prior to          Loose    specifying contact us or your local              Fabric    representative for a recommendation and test    sample.5. In oversize panels, wider than 48 inches (1,2 m)    and longer than 120 inches (3 m), it might be    possible to \"see\" where the fiberglass sheets    are joined through the fabric. This is called    telegraphing and is usually emphasized by light    conditions.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 29 of 33     Section 15. Panel Maintenance 1. A regular maintenance program, particularly vacuuming, ensures that the     installation will keep its fresh look for a long time. 2. For vinyl, clean lightly with ordinary household detergents using a soft cloth.     Rub lightly! Use the detergent sparingly, as a heavy application might fill in     the perforations and alter the acoustical performance. 3. For fabrics, follow the fabric manufacturer’s recommendations unless it is in     conflict with our information. 4. Make certain that temperature and humidity are maintained within normal     range and that the core is not dampened. 5. Avoid alcohol and all solvents as they might cause the core and the     finishing material to separate. 6. Test all cleaning material on the fabric or vinyl return on the back of the     panels before proceeding. 7. Clean hands or wear clean gloves before handling panels and avoid any     unnecessary handling. 8. All acoustic panels and fabrics required regular reapplication of Fire     retardants in order to maintain fire resistance.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 30 of 33   Section 16. Sound tests          I. Sound Test 1Sound Absorption Test ASTM C423                                          TEST DESCRIPTION          TESTED BY: National Research Council, Ottawa, Canada          Report No. A-1006.2          TEST DATE: 09/13/91          TEST MATERIAL: 1” (25 mm) fiberglass, vinyl cover          E795 MOUNTING CODE: A, modified. Air space 5/16”          DESCRIPTION:                   Open office wall panels, 25 mm thick                   Smoke blue cloth cover                   Panels resting on wall-mounted clips                   Two panels butted together, each 4 ft. 9 ft.            the full report of the test results are available on request.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 31 of 33          II. Sound Test 2Sound Absorption Test ASTM C423                                      TEST DESCRIPTION      TESTED BY: National Research Council, Ottawa, Canada      Report No. A-1006.4      TEST DATE: 09/13/91      TEST MATERIAL: 2” (51 mm) fiberglass, fabric cover      E795 MOUNTING CODE: A, modified. Air space 5/16”      DESCRIPTION:               Open office wall panels, 51 mm thick               Smoke blue cloth cover               Panels resting on wall-mounted clips               Two panels butted together, each 4 ft. 9 ft.       the full report of the test results are available on request.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 32 of 33III. Sound Test 3                                          TEST DESCRIPTION          TESTED BY: National Research Council, Ottawa, Canada          Report No. A-1006.3          TEST DATE: 09/31/91          TEST MATERIAL: 3/4” (19 mm) fiberglass, fabric cover          E795 MOUNTING CODE: A, modified. Air space 5/16”          DESCRIPTION:                   Open office wall panels, 19 mm thick                   Smoke blue cloth cover                   Panels resting on wall-mounted clips                   Two panels butted together, each 4 ft. 9 ft.            the full report of the test results are available on request.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
Page 33 of 33IV. Sound Test 4                                        TEST DESCRIPTION        TESTED BY: National Research Council, Ottawa, Canada        Report No. A-1006.1        TEST DATE: 09/13/91        TEST MATERIAL: 1” (25 mm) fiberglass, fabric cover        E795 MOUNTING CODE: A, modified. Air space 5/16”        DESCRIPTION:                 Open office wall panels, 25 mm thick                 Smoke blue cloth cover                 Panels resting on wall-mounted clips                 Two panels butted together, each 4 ft. 9 ft.         the full report of the test results are available on request.1305 Industrielle, La Prairie, Qc. J5R 2E4 | Tel: 450-444-7414 & 1-800-724-6600 | Fax: 450-444-7074                                           www.rampart.ca | [email protected]
                                
                                
                                Search
                            
                            Read the Text Version
- 1 - 33
 
Pages: