RELIABLE TOP QUALITY AND TIGHT COMPONENTSCONSTRUCTION
INTELLIGENT SAFETY CONTROL OF USE SYSTEMS
STRUCTURE AZ 150 ALUZINC SHEET RESISTANCE TO CORROSION 3000 2412 VENTUS AHU 2500 new coating resistanceNumber of hours 2000 1500 1000 500 162 0 Galvanised Aluzinc 20 Mu Z275 20 Mu AZ150Salt spray test according to ASTM B-117CASING SKIN FAN SECTION CAGE»» metal sheet thickness increased by 20% »» increased longitudinal stiffness»» increased rigidity and durability of the structure of the AHU structure »» easier sections assembly»» low absorption of heat radiation and UV»» increased resistance to weather conditions
ALUMINIUM COLUMNS AS STANDARD FOR ALL TYPES OF UNITSZ PROFILE C PROFILE VS 21-150 VS 180-650GALVANIZED STEEL SUPPORTAS STANDARD FOR ALL TYPES OF UNITSFRAME STRUCTURAL COLUMNS»» easier transport »» thermal breaks on the mullion as standard»» greater profile resistance to deflection »» high resistance to weather conditions and UV rays
TIGHTNESS SMART HINGE SYSTEM VTS PATENTED PROPRIETARY SOLUTION INSPECTION PANELS EQUIPPED WITH THE OPEN / CLOSE SMART SYSTEM AND NEW PROTECTIVE CORNERS »» easy to use, enabling quick opening and closing of the inspection panel »» smart hinge - prevents seal breaking when the panel is opened (VTS proprietary and patented solution) »» improved ergonomics with an integrated handle and hinge function »» reduced risk of panel damage
THERMAL ADDITIONAL BREAK COLUMN SEALINGLABYRINTH ADDITIONAL SEALING SEALING FINSALUMINIUM STRUCTURAL COLUMNS WITH AN ADDITIONAL SEALING FINAND A THERMAL BREAK»» thermal breake as standard - ensures no condensation outside the AHU»» the fin ensures labyrinth sealing - currently the most effective solution on the market, mainly used in laboratory equipment»» original solution consisting in the use of symmetrical channel tension filled with a sealing compound, which provides 100% tightness of the connection between the column and construction structure
CONTROLSNEW FEATURESMEASUREMENT AND CONTROL ELECTRIC HEATER CONTROLOF THE CONSTANT AIR VOLUME »» smooth control system that adjusts»» adjustment of the preset constant air instantaneous power to the current demand volume under changing flow resistance - compensation of changing internal resistance of the AHU (e.g. with varying degrees of air filter dirt, different setpoint of the mixing box, etc.)»» adjustment of the fan power to the current needs of the installation»» immediate readiness of the AHU to work with the required performance immediately after installationCONSTANT PRESSURE CONTROLWITH VARIABLE AIR VOLUME»» control of constant, preset air pressure at variable volume (efficiency change is carried out through the air distribution system – e.g. VAV controllers)CO2 HUMIDITY CONTROL»» automatic reduction of the amount »» control over air humidifying coof nocuetsnitdreataioirn(kbeeelopwingthteheseCtOv2alue) - both evaporative and steam»» optimisation of consumption of heat »» supports control the drying process and electricity MIXING BOX CONTROLCONTROL OF VS21 – 150 BACKUPENGINES »» smooth control of the mixing box, external signal or as in the CO2 control»» adaptation to the special needs function, etc. of the building »» optimization of the ventilation air»» protection in case of failure to save energy of the first engine
MAIN and LX HMI SMART HMINEW RANGE OF CONTROLLERS ULTRA+ SMART MAIN LX • • 1 source • • •SOURCE 2 sources • • •OF HEATING 3 sources •/COOLING 4 and more sources • • •COMMUNICA- TCP/IP Modbus • •TION WITH MAS- WebServer •TER SYSTEM BacNET • • • Dual methode of heating coil freeze protection • • • (low limit thermostat on the air and water side) • • Energy recovery systems frost protection • •FUNCTIONS (temperature sensor downstreem energy recovery section) • • Measurement and control of the constant air volume (CAV) • Measurement and maintennance of air volume based • on system required pressure (VAV) • Control of the concentration of carbon dioxide in the air • Air humidity control Pre-heater control for extreme low temperatures (maximization of the energy recovery performance)SOURCES OF HEATING/COOLING »»Mixing box»»Primary heater »»Primary heater (before recovery of heat), electric/water»»Primary cooler »»Reheat coil (mainly used for drying)»»The recovery (plate heat exchanger or a rotary exchanger, glycol system)
SAFETY OF USEHANDLE OPEN PROTECTION FAN SAFETY BARRIER»» increased safety against accidental »» protection against fan in-operation opening of the fan section
PANEL CLOSED Contact PANEL OPENED Reed switchContact closed – fan start permitted PLUG fan section Contact open – fan start prohibited Contact Contact Reed switch Reed switchPLUG fan section PLUG fan section REED SWITCH Contact Reed switch »» electronic stop of thPLeUG motorfan section when the panel is opened