street and external lighting specialist lighting from the ground up
About Us One Stop Shop BEI lighting is the UK’s largest street lighting distributor and holds unrivalled stock of lighting columns as well as road lanterns, discharge lamps and control gear. With over 30 years experience in the lighting industry we offer friendly unbiased solutions for your external lighting project management. We can provide a quality service in several sectors at competitive rates, regardless of quantity to the following: - Electrical Wholesalers - Local Authorities - Electrical Contractors - Consultants - Architects Service, quality and quantity has given us a strong and wide customer base. Only through listening and reacting to our customers needs has BEI grown year on year. Our customers and suppliers have secured a part in the success we share today. 2 street and external lighting specialist
Web Presence Please feel free to visit our constantly updated website www.beilighting.com 3
Contents SERVICES Paintshop Facility 6 Quality Assurance 7 Fabrication Facility 8 lighting from the ground up Associations 10 Transport 11 Lighting Design 11 COLUMNS Tubular 14 Tubular Mid Hinged 16 Tubular Base Hinged 17 Stainless Steel 18 Aluminium 19 1 Conical 20 Octagonal 21 Wooden 22 Flanges and Anchor Bolts 24 Installation Sheet 25 Wind Zone Guide 26 BRACKETRY Floodlight Brackets 30 Lantern Brackets 33 Post Top Brakets 35 2 Bespoke Brackets 37 Spigots 42 Column Guards 43 Guardrails 44 AMENITY LIGHTING Globe 48 Holyhead 50 Bangor 52 3 Brecon 54 Snowdon 56 Bollards 58 Signs 62 FLOODLIGHTING Polycarbonate 66 Aluminium 68 Non Corrosive 70 Marine Grade 72 Titan 74 4 SONPAK LX7 76 SONPAK LX15/25/40 78 Champion 80 BEI 1S 82 BEI 2S 84 ANCILLARY LIGHTING LED Bulkhead 88 Wallpack 90 5 Slim LED Wallpack 92 LED Wallpack 94 4 street and external lighting specialist
Contents SOLAR LIGHTING 6 Exmoor 100 98 Dartmoor Quantock Solar Bollards 102 104 MINOR ROAD LIGHTING P567A 108 BEI Air 110 BEI Explorer 112 7 Odyssey LED 114 Arc 116 118 Luma Mini Luma 1 120 Civiteq 122 P850 124 Cheviot 126 LED Sky 128 MAJOR ROAD LIGHTING 8 P680 132 134 CiviTEQ Large 136 Isaro Luma 2 138 P862 140 PERIOD FIXTURES & STREET FURNITURE 144 Period Column Embelishments 9 P516 Lantern 146 Strand 148 Windsor 152 Knightsbridge 150 Street Furniture 154 Street Charge 156 LAMPS 10 GE 162 163 Philips Venture 168 INDO Retrofi t Gear Tray 164 CMS SYSTEMS & CONTROL GEAR 11 Lucy Zodion CMS 172 174 Mayfl ower CMS Philips CMS Telensa CMS 176 178 Philips Control Gear 180 ACCESSORIES 12 Royce Thompson 184 Lucy Zodion 185 Charles Endirect 190 Keys 188 5 street and external lighting specialist
Paint Shops In House Painting Facilities BEI operate three in-house paint shops which Using the latest paint technologies, such as can provide an internal capacity of 50,000 PSX700 and Glass Flake Root fi nishes. We can square feet. A recent major investment in provide our customers with high specifi cation the latest heating and extraction systems products that greatly extended a columns life. has enabled us to increase our capacity and We can also provide Belisha Beacon Posts reduce lead times. with a refl ective surface. We have the capability to paint large orders of On site painting means BEI has the fl exibility to columns per week, enabling us to assist with paint to a customers specifi c requirements. PFI contracts and large projects. All materials are handled with the utmost of care right through the process, making quality Finishes from simple T-Wash and Etch Primer, control of prime importance. to Department of Transport specifi cations, such as G2A and G2B, PSX Polysiloxane, Our workforce is trained to use the latest, Glass Flake Root treatments and top coat modern technology, monitoring both wet and RAL or BS paint fi nishes to any specifi c colour dry fi lm thickness throughout, ensuring that all required. work meets the specifi cation required. 6 street and external lighting specialist
Quality Assurance Customer confi rms paint specifi cation Column painted and tested Data logged, including paint thickness, temperature and humidity Column labelled for full traceability Did you Know? BEI can offer the following paint fi nishes: - G2A - G2B - PSX - Glass Flake Root - RAL and BS Future column traceability - T-Wash Primer TO SEE AN EXAMPLE SCAN ME NOW! 7 street and external lighting specialist
8 street and external lighting specialist
Fabrication Fabrication Facilities BEI is a unique distributor in that we have our own in-house fabrication facilities. We manufacture our own bracketry, as well as being able to manufacture bespoke brackets to customers specifi c requirements. Using our staff whom are all coded welders with up to 30 years experience we provide high specifi cation steelwork from receipt of order to customer generally within 7 days. We are also able to provide modifi cations to columns to meet customer specifi c requirements, such as: - Flange Plates - Cranked Root - Bespoke Sign Posts - Offset Shafts - Column Guards/Protectors - Anti Climb Spikes - Bespoke Cabinets/Columns - Column Racking - Wire Cages 9 street and external lighting specialist
Associations Our “one stop shop” philosophy means we are able to supply everything from cable to cut outs to photocells. In summary our logo says it all “lighting from the ground up”. Based on a 6 acre site in Bridgend, South Wales, we offer a delivery service throughout the UK, using our own fl eet of bespoke vehicles with HIAB offl oading at no extra charge. Our commitment to the industry also means that we are a member of HEMSA - the Highway Electrical and Manufacturers Suppliers Association and also the ILP - the Institute of Lighting Professionals. 10 street and external lighting specialist
Transport Fleet Operating its own fl eet of bespoke vehicles BEI delivers on a weekly basis, with UK coverage, to best service its customers needs. Our current fl eet consists of the following vehicle types; - Artic with Hiab - Flat Bed with Hiab - Curtain Sider - 3.5 Tonne As part of our expansion plans we are currently investing further in new vehicles. All BEI vehicles are tracked and fi tted with the latest navigation/ telephone systems enabling us to give live updates on deliveries. Column deliveries are offl oaded by HIAB at no extra cost. Lighting Design Lighting Designs/Schemes Utilising close links with our preferred suppliers we are able to offer lighting designs and quotations upon request. By always using these key suppliers we ensure that products supplied have the relevant photometric data available upon request. This unbiased approach means we always offer the best solution for each project. Horizontal Illuminance (lux) Main Results Eav 30.65 Emin 17.46 Emax 53.86 Emin/Emax 0.32 Emin/Eav 0.57 11 street and external lighting specialist
Columns 1 LIGHTING COLUMNS BEI hold the UK’s largest stock of street lighting columns, available off the shelf within 7 days. Products stocked include: - Tubular Steel - Octagonal Steel - Tubular Mid Hinged - Octagonal Mid Hinged - Tubular Base Hinged - Conical / Tapered Steel - Passively Safe - Sign Posts - Straight Posts - Masts - Aluminium - Stainless Steel 12 street and external lighting specialist
Columns 1 13 street and external lighting specialist
Columns 1 F F Design BSEN40, PD6547: 2004+A1: 2009. TUBULAR ØD A *Maximum design head load Extra heavy wind loading region (No sign). Load class B / Defl ection class 3. based on wind loading region with orientation of bracket/luminaire(s) being on same plane as door. 15 4 No. 15 x 25 Castle Slots Equi-Sp. 90° ØD A 50 206 25 SECTION F 600 x 115 600 x 115 aperture for aperture for wrap around door wrap around door 420 300 B B G.L. 420 300 25 ØC G.L. 150 x 75 SECTION B-B 4 No. slots 30 x 70 Cable slot for M24 bolts B ØC GROUP A WITH INTEGRAL REDUCER Code 8TG 8TG-HD 10TG 10TG-HD 12TG-HD A (Mtr) 7.7 7.7 9.7 9.7 11.7 B (mm) 1200 1200 1500 1500 1700 C (mm) 168 168 168 192 192 D (mm) 89 114 114 114 168 Door Aperture (mm) 600x115 600x115 600x115 600x115 600x115 2 Max Head load (Kg/m *) 30 / 0.25 40 / 0.45 30 / 0.28 50 / 0.48 85 / 0.80 GROUP A WITH INTEGRAL REDUCER FLANGE PLATED Code 8TG/FP 8TG-HD/FP 10TG/FP 10TG-HD/FP 12TG-HD/FP A (Mtr) 7.7 7.7 9.7 9.7 11.7 B (mm) N/A N/A N/A N/A N/A C (mm) 168 168 168 192 192 D (mm) 89 114 114 114 168 Door Aperture (mm) 600x115 600x115 600x115 600x115 600x115 Max Head load (Kg/m *) 30 / 0.25 40 / 0.45 30 / 0.28 50 / 0.48 85 / 0.80 2 Hole Centres (mm) 300x300 300x300 300x300 300x300 300x300 Bolts M24 M24 M24 M24 M24 14 street and external lighting specialist
Columns 1 Design BSEN40, PD6547: 2004+A1: 2009. Extra heavy wind loading region (No sign). Load class B / Defl ection class 3. *Maximum design head load based on wind loading region with orientation of bracket/luminaire(s) being on same plane as door. ØD TUBULAR ØD A A 500 x 100 aperture for 500 x 100 wrap-around door aperture for wrap around door B B G.L. 20 ØC G.L. 150 x 75 Cable slot B ØC GROUP B POST TOP FLANGE PLATED Code 3TG/FP 4TG/FP 5TG/FP 6TG/FP A (Mtr) 3 4 5 6 B (mm) N/A N/A N/A N/A C (mm) 140 140 140 140 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 500x100 500x100 Max Head load (Kg/m *) 50 / 0.05 50 / 0.05 40 / 0.4 30 / 0.25 2 Hole Centres (mm) 200x200 200x200 200x200 200x200 Bolts M16 M16 M16 M16 GROUP B POST TOP Code 3TG 4TG 5TG 6TG A (Mtr) 3 4 5 6 B (mm) 800 800 800 1000 C (mm) 140 140 140 140 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 500x100 500x100 2 Max Head load (Kg/m *) 50 / 0.05 50 / 0.05 40 / 0.4 30 / 0.25 15 street and external lighting specialist
Columns 1 F Design BSEN40, PD6547: 2004+A1: 2009. TUBULAR MID-HINGED Extra heavy wind loading region (No sign). E E E Load class B Defl ection class 3. *Maximum design head load based on wind loading region with orientation of bracket/luminaire(s) being on same plane as door. Note: Raise and Lowering equipment may be required, please ask for details before ordering. D D D A A A twin lock twin lock twin lock flush door flush door flush door Winch Mounting Winch Mounting Winch Mounting Boss (x2) Boss (x2) Boss (x2) B B 15 G.L G.L G.L 4 No. 15 x 25 Castle Slots 25 C 25 Equi-Sp. 90° 206 Cable slot Cable slot SECTION F B 150 x 75mm B B 150 x 75mm 50 C C 420 TUBULAR MID-HINGED FLANGE PLATED 300 Code A B C D E Door Aperture Max Head load Hole Centres Bolts 4TMG/FP 4Mtr N/A 140mm 89mm 76mm 600mm x 115mm 50Kg/0.50m² * M16 5TMG/FP 5Mtr N/A 140mm 89mm 76mm 600mm x 115mm 45Kg/0.39m² * 420 300 200 x 200 M16 200 x 200 6TMG/FP 6Mtr N/A 140mm 89mm 76mm 600mm x 115mm 30Kg/0.20m² * 200 x 200 M16 8TMG/FP 7.7Mtr N/A 168mm 89mm 76mm 600mm x 115mm 30Kg/0.25m² * 300 x 300 4 No. slots SECTION B-B M24 30 x 70 for M24 bolts TUBULAR MID-HINGED Code A B C D E Door Aperture Max Head load 4TMG 4Mtr 1000mm 140mm 89mm 76mm 600mm x 115mm 50Kg/0.50m² * 5TMG 5Mtr 1000mm 140mm 89mm 76mm 600mm x 115mm 45Kg/0.39m² * 6TMG 6Mtr 1000mm 140mm 89mm 76mm 600mm x 115mm 30Kg/0.20m² * 8TMG 7.7Mtr 1200mm 168mm 89mm 76mm 600mm x 115mm 30Kg/0.25m² * 16 street and external lighting specialist
Columns 1 F Design BSEN40, PD6547: 2004+A1: 2009. Extra heavy wind loading region (No sign) ection class 3. flLoad class B De *Maximum design head load based on wind loading region with orientation of bracket/luminaire(s) being on same plane as door. Note: Raise and Lowering equipment may be required, please ask for details before ordering. ØD ØD ØD A A A TUBULAR BASE-HINGED twin lock flush door twin lock flush door twin lock flush door 15 4 No. 15 x 25 B B Castle Slots Equi-Sp. 90° G.L. G.L. G.L. 206 25 25 ØC SECTION F 50 B B 420 TUBULAR BASE-HINGED FLANGE PLATED 300 Code A B C D E Door Aperture Max Head load Hole Centres Bolts 4TBG/FP 4Mtr N/A 140mm 76mm N/A 600mm x 115mm 50Kg/0.50m² * 200 x 200 M16 420 5TBG/FP 5Mtr N/A 140mm 76mm N/A 600mm x 115mm 40Kg/0.36m² * 300 200 x 200 M16 6TBG/FP 6Mtr N/A 140mm 76mm N/A 600mm x 115mm 30Kg/0.20m² * 200 x 200 M16 300 x 300 8TBG/FP 7.7Mtr N/A 152mm 89mm 76mm 600mm x 115mm 30Kg/0.30m² * SECTION B-B 4 No. slots M24 30 x 70 for M24 bolts TUBULAR BASE-HINGED Code A B C D E Door Aperture Max Head load 4TBG 4Mtr 1000mm 140mm 76mm N/A 600mm x 115mm 50Kg/0.50m² * 5TBG 5Mtr 1000mm 140mm 76mm N/A 600mm x 115mm 40Kg/0.36m² * 6TBG 6Mtr 1000mm 140mm 76mm N/A 600mm x 115mm 30Kg/0.20m² * 8TBG 7.7Mtr 1200mm 152mm 89mm 76mm 600mm x 115mm 30Kg/0.30m² * 17 street and external lighting specialist
Columns 1 Design BSEN40, PD6547: 2004+A1: 2009. STAINLESS STEEL Extra heavy wind loading region (No sign). Load class B / Defl ection class 3. *Maximum design head load based on wind loading region with orientation of bracket/ luminaire(s) being on same plane as door. For further information on Stainless Steel Columns contact BEI 18 street and external lighting specialist
Columns 1 ØD Design BSEN40, PD6547: 2004+A1: 2009. ALUMINIUM Extra heavy wind loading region (No sign). Load class B / Defl ection class 3. * Maximum design head load based on Post Top Rationalised Extra Heavy Wind Loading Region. Terrain Category III. A aperture for wrap-around door G.L. 150 x 75 cable slot B ØC STATIC ROOTED Code 5CA 6CA 8CA 10CA A (Mtr) 5 6 8 10 B (mm) 800 1000 1200 1500 C (mm) 150 150 165 200 D (mm) 75 75 75 75 Door Aperture (mm) 500x100 500x100 600x115 600x115 Max Head load (Kg/m *) 15 / 0.37 15 / 0.22 15 / 0.12 15 / 0.39 2 Other loadings possible, please ask for details 19 street and external lighting specialist
Columns 1 ØD ØD Design BSEN40, PD6547: 2004+A1: 2009. CONICAL * Maximum design head load Extra heavy wind loading region (No sign) Load class B / Defl ection class 3 / Terrain Category II. based on wind loading region with orientation of bracket/ luminaire(s) being on same plane as door. A A Single lock wrap-around door Single lock wrap-around door G.L. 15 ØC G.L. 150 x 75 cable slot B ØC CONICAL Code 4CG 5CG 6CG 8CG A (Mtr) 4 5 6 8 B (mm) 800 800 1000 1200 C (mm) 143 157 174 204 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 500x100 600x115 2 Max Head load (Kg/m *) 40 / 0.40 40 / 0.40 40 / 0.40 40 / 0.45 CONICAL F/PLATED Code 4CG/FP 5CG/FP 6CG/FP 8CG/FP A (Mtr) 4 5 6 8 B (mm) N/A N/A N/A N/A C (mm) 132 146 160 188 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 500x100 600x115 Max Head load (Kg/m *) 40 / 0.40 40 / 0.40 40 / 0.40 40 / 0.45 2 Hole Centres 200x200 200x200 200x200 300x300 Bolts M16 M16 M16 M24 20 street and external lighting specialist
Columns 1 ØD ØD ØD ØD Design EN40. OCTAGONAL *Max head loading based on extra heavy wind area and a winch being used. For other head weights please call our sales offi ce. A A A A E E aperture for wrap-around door 300 aperture for 300 wrap-around door 15 15 1065 300 1065 300 15 15 C G.L. C G.L. C C G.L. G.L. 500 500 500 150 x 75 500 150 x 75 150 x 75 cable slot cable slot B150 x 75 cable slot cable slot B B B ØC ØC ØC ØC OCTAGONAL STATIC OCTAGONAL MID-HINGED Code 4.70G 5.70G 80G 100G Code 60MG 80MG 100G 120G A (Mtr) 4.7 5.7 6 + 2 8 +2 A (Mtr) 6 8 10 12 B (mm) 800 1000 1200 1500 B (mm) 1000 1200 1500 1700 C (mm) A/F 165 165 195 215 C (mm) A/F 233 233 282 300 D (mm) 74x100 74x100 75 75 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 600x115 600x115 E (mm) 2550 3550 4550 4030 Max Head load (Kg/m 2 *) 30 / 0.29 15 / 0.13 60 / 0.60 50 / 0.55 Door Aperture (mm) 600x115 600x135 600x135 600x135 Max Head load (Kg/m 2 *) 150 / 1.7 150 / 0.95 150 / 0.97 150 / 1.3 OCTAGONAL STATIC F/PLATED OCTAGONAL MID-HINGED F/PLATED Code 4.70G/FP 5.70G/FP 80G/FP 100G/FP Code 60MG/FP 80MG/FP 100G/FP 120G/FP A (Mtr) 4.7 5.7 6 + 2 8 +2 A (Mtr) 6 8 10 12 B (mm) N/A N/A N/A N/A B (mm) 1000 1200 1500 1700 C (mm) A/F 151 151 176 255 C (mm) A/F 233 233 282 300 D (mm) 76 76 76 76 D (mm) 76 76 76 76 Door Aperture (mm) 500x100 500x100 600x115 600x115 E (mm) 2550 3550 4550 4030 Max Head load (Kg/m 2 *) 30 / 0.29 15 / 0.13 60 / 0.60 50 / 0.55 Door Aperture (mm) 600x115 600x135 600x135 600x135 Hole Centres 200x200 200x200 300x300 300x300 Max Head load (Kg/m 2 *) 150 / 1.7 150 / 0.95 150 / 0.97 150 / 1.3 Bolts M16 M16 M24 M24 Hole Centres 300x300 300x300 300x300 300x300 Bolts M24x820 M24x820 M24x820 M24x820 21 street and external lighting specialist
Columns 1 WOODEN WOODEN COLUMNS 22 street and external lighting specialist
Columns Wooden columns available contact BEI for more information 23 street and external lighting specialist
Columns 1 A Dia FLANGES Flange Plate Details D B Square C Door opening and bracket arm centre arms always correspond with vertical or C horizontal centre E Dia lines on this view ANCHOR BOLTS BEI are able to offer a comprehensive Stock bolts are also available overnight range of sizes from stock which include allowing groundwork to be completed in stainless steel, galvanised steel and a timely manner. other materials upon request. The table shows our standard range of A quick turnaround on fl ange plated bolts and plate sizes, please note that columns is offered, as we manufacture we can supply variations on this using these ourselves in our fabrication shop. our in-house fabrication facilities. GEAR BASE TO SUIT 76MM POST TOP COLUMN TYPE NO COLUMN NOMINAL A B C D E HEIGHT (M) (mm) (mm) (mm) (mm) (mm) FP1 4 / 5 114.3 12 FP2 4 / 5 / 6 139.7 265 200 12 20 FP3 168.3 12 FP4 8 15 FP5 8 168.3 400 300 20 30 FP6 10 22 FP7 8 20 FP8 10 / 12 193.7 400 300 25 30 FP9 12 30 FP10 10 25 FP11 10 / 12 219.1 400 300 30 30 FP12 12 35 24 street and external lighting specialist
Columns 1 COLUMN INSTALLATION Note This method is suitable for normal cohesive soil. If soil is “sandy” or for heavily loaded columns, use more concrete and plastic duct into cable entry. N.B. It is the responsibility of the installer to ensure the suitability of this method and no liability arising from it’s use will be accepted by BEI Lighting. CONCRETE/TARMAC/ COLUMN INSTALLATION ASPHALT FINISH ETC GROUND LEVEL BACKFILL LEVEL CABLE ENTRY SLOT CONCRETE LEVEL (to just under cable entry slot) SLAB OR BRICK (to prevent sinking) Guidance Notes: 1. Excavate hole approx. 100mm / 200mm larger than the base of column diameter to full depth of root. 2. Place a slab or brick (to prevent sinking). 3. Using a semi-dry concrete mix, put bottom covering in fi rst, then lower column on to slab. 4. Continue concrete fi lling (to just under cable entry slot), and insert SWA cable. 5. Compact excavated material as backfi ll on top of concrete. 6. If required, use concrete/tarmac/asphalt fi nish. 25 street and external lighting specialist
Columns 1 Administrative Area Maximum 10 Min Mean Rationalized Administrative Area Maximum 10 Min Mean Rationalized Altitude Wind Velocity Wind Loading Altitude Wind Velocity Wind Loading (m) Region Region (m/sec) (m/sec) (m) Aberdeen 25.73 Heavy 22.58 250 Merthyr Tydfi l Aberdeenshire 141 25.20 Heavy Merseyside 142 24.15 Medium Heavy 117 Angus 250 25.20 Extra Heavy Mid Lothian 141 25.20 Heavy Antrim 217 26.25 Extra Heavy Middlesbrough 95 26.25 Heavy Argyll and Bute 170 27.30 Extra Heavy Milton Keynes 202 22.05 Light WIND ZONE GUIDE Armagh 250 24.68 Extra Heavy Monmouthshire & Newport 202 22.05 Light Bath & North East Somerset 250 22.05 Medium Moray 250 25.20 Extra Heavy Bedfordshire 147 23.10 Light Neath Port Talbot 193 23.10 Medium Blackburn & Darwen 142 24.15 Medium Norfolk 95 26.25 Heavy Blackpool 98 24.15 Light North Ayrshire 217 26.25 Extra Heavy Blaenau Gwent 250 22.05 Medium North East Lincs 52 25.20 Light Bournemouth 98 24.15 Light North Lanarkshire 190 24.15 Heavy Bracknell Forest 250 21.00 Light North Lincs 94 25.20 Medium Bridgend 221 22.58 Medium North West Somerset 202 22.05 Light Brighton and Hove 147 23.10 Light North Yorkshire 95 26.25 Heavy Bristol 231 21.53 Light Northamptonshire 147 23.10 Light Buckinghamshire 202 22.05 Light Northumberland 50 26.25 Medium Caerphilly 250 22.05 Medium Nottingham 147 23.10 Light Carmarthenshire 250 25.20 Extra Heavy Nottinghamshire 142 24.15 Medium Cambridgeshire 117 24.68 Medium Orkney 87 29.40 Extra Heavy Cardiff 250 22.05 Medium Oxfordshire 250 21.00 Light Ceredigion 142 24.15 Medium Pembrokeshire 142 24.15 Medium Channel Islands 141 25.20 Heavy Perth & Kinross 165 24.68 Heavy Cheshire 193 23.10 Medium Peterborough 98 24.15 Light Clackmannanshire 190 24.15 Heavy Plymouth 142 24.15 Medium Conwy 250 24.15 Extra Heavy Poole 147 23.10 Light Cornwall 141 25.20 Heavy Portsmouth 147 23.10 Light Cumbria 242 25.73 Extra Heavy Powys 193 23.10 Medium Darlington 72 25.73 Medium Reading 250 21.00 Light Denbighshire 244 23.10 Heavy Redcar & Cleveland 95 26.25 Heavy Derbyshire 193 23.10 Medium Renfrewshire 250 25.20 Extra Heavy Devon 142 24.15 Medium Rhondda Cynon Taff 250 22.58 Heavy Dorset 193 23.10 Medium Rutland 122 23.63 Light Dumfries & Galloway 117 25.73 Heavy Scottish Borders 117 25.73 Heavy Dundee 242 25.73 Extra Heavy Shropshire 250 22.58 Heavy Durham 217 26.25 Extra Heavy Slough 250 21.00 Light East Ayrshire 117 25.73 Heavy Somerset 193 23.10 Medium East Dunbartonshire 165 24.68 Heavy South Ayrshire 117 25.73 Heavy East Lothian 141 25.20 Heavy South Gloucester 231 21.53 Light East Renfrewshire 250 25.20 Extra Heavy South Lanarkshire 165 24.68 Heavy East Riding of Yorkshire 217 26.25 Extra Heavy South Yorkshire 142 24.15 Medium East Sussex 147 23.10 Light Southampton 174 22.58 Light Edinburgh 165 24.68 Heavy Southend 147 23.10 Light Essex 167 23.63 Medium Staffordshire 221 22.58 Medium Falkirk 190 24.15 Heavy Stirling 250 25.20 Extra Heavy Fermanagh 250 25.20 Extra Heavy Stockton on Tees 72 25.73 Medium Fife 141 25.20 Heavy Stoke on Trent 221 22.58 Medium Flintshire 193 23.10 Medium Suffolk 94 25.20 Medium Glasgow 165 24.68 Heavy Surrey 250 22.58 Heavy Gloucestershire 231 21.53 Light Swansea 167 23.63 Medium Greater London 174 22.58 Light Swindon 250 21.00 Light Greater Manchester 167 23.63 Medium Telford & Wrekin 202 22.05 Light Gwynedd 250 25.2 Extra Heavy Thurrock 174 22.58 Light Hampshire 147 23.10 Light Torbay 122 23.63 Light Hartlepool 95 26.25 Heavy Torfaen 250 22.05 Medium Herefordshire 202 22.05 Light Tyne and Wear 217 26.25 Extra Heavy Hertfordshire 147 23.10 Light Tyrone 250 25.20 Extra Heavy Highland 127 28.35 Extra Heavy Vale of Glamorgan 221 22.58 Medium Inverclyde 242 25.73 Extra Heavy Warrington 147 23.10 Medium Isle of Anglesey 94 25.20 Medium Warwickshire & Coventry 250 22.05 Medium Isle of Man 94 25.20 Medium West Berkshire & Newbury 250 21.00 Light Isle of Wight 147 23.10 Light West Dunbartonshire 141 25.20 Heavy Isles of Scilly 52 25.20 Light West Lothian 190 24.15 Heavy Kent 167 23.63 Medium West Midlands 231 21.53 Medium Kingston upon Hull 52 25.20 Light West Sussex 147 23.10 Light Lancashire 141 25.20 Heavy West Yorkshire 250 24.68 Extra Heavy Leeds City 250 24.68 Extra Heavy Western Isles 87 29.40 Extra Heavy Leicester 174 22.58 Light Wiltshire 202 22.05 Light Leicestershire 193 23.10 Medium Windsor & Maidenhead 250 21.00 Light Lincolnshire 94 25.20 Medium Wokingham 250 21.00 Light Londonderry 217 26.25 Extra Heavy Worcestershire 231 21.53 Light Luton 202 22.05 Light Wrexham 221 22.58 Medium Medway 174 22.58 Light York 52 25.20 Light 26 street and external lighting specialist
Columns 1 1 WIND ZONE GUIDE 27 street and external lighting specialist
Bracketry BRACKETRY 2 BEI has its own in-house manufacturing facilty enabling us to produce bracketry to your requirements quickly and effi ciently. We offer side entry, post top and fl oodlight column brackets as well as bespoke brackets to customer drawings. 28 street and external lighting specialist
Bracketry 2 29 street and external lighting specialist
Bracketry X1 STYLE 150 75 76x38x7 CHANNEL 2 150 75 11 11 HOLE THRU CHANNEL TAP M16x2 - 6H 300 HOLE Ø35 THRU PLATE 150 26 26 A FLOODLIGHT BRACKETS 4 HOLES THRU EQUISPACED RADIALLY TAP M10x1.5-6H 26 FIT 4 M10x10 LONG PLATE 3 THICK FLAT POINT SOCKET TUBE LENGTH 200 SET SCREWS 100 TO SUIT COLUMN A 150 75 76x38x7 CHANNEL X2 STYLE 75 150 11 11 HOLE THRU CHANNEL TAP M16x2 - 6H 2 POS HOLE Ø35 THRU PLATE 26 26 600 300 4 HOLES THRU A EQUISPACED RADIALLY TAP M10x1.5-6H FIT 4 M10x10 LONG PLATE 3 THICK FLAT POINT SOCKET TUBE LENGTH 200 26 SET SCREWS 100 TO SUIT COLUMN A GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All channel to be BS4: PART 1: 2005 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 Brackets to suit 60mm column shaft or spigot X1-76 Single fl oodlight bracket X2-76 Twin fl oodlight bracket Brackets to suit 76mm column shaft or spigot X1-89 Single fl oodlight bracket X2-89 Twin fl oodlight bracket Brackets to suit 114mm column with integral spigot X1-114 Single fl oodlight bracket X2-114 Twin fl oodlight bracket Brackets to suit 140mm column with integral spigot X1-140 Single fl oodlight bracket X2-140 Twin fl oodlight bracket 30 street and external lighting specialist
Bracketry X3 STYLE 300 300 76x38x7 CHANNEL 75 2 75 11 150 11 HOLE THRU CHANNEL TAP M16x2 - 6H 150 HOLE Ø35 THRU PLATE 3 POS 26 26 1300 4 HOLES THRU 650 A EQUISPACED RADIALLY TAP M10x1.5-6H FIT 4 M10x10 LONG PLATE 3 THICK TUBE LENGTH 200 FLAT POINT SOCKET SET SCREWS 100 26 TO SUIT COLUMN A X4 STYLE 900 900 300 300 75 76x38x7 CHANNEL 75 HOLE Ø35 THRU PLATE 26 26 150 HOLE THRU CHANNEL 4 HOLES THRU TAP M16x2 - 6H EQUISPACED RADIALLY 150 4 POS TAP M10x1.5-6H FIT 4 M10x10 LONG PLATE 3 THICK TUBE LENGTH 200 FLOODLIGHT BRACKETS 1300 FLAT POINT SOCKET 650 SET SCREWS 100 A TO SUIT COLUMN A 26 GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All channel to be BS4: PART 1: 2005 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 Brackets to suit 76mm column shaft or spigot Brackets to suit 76mm column shaft or spigot X3-89 Triple in-line fl oodlight bracket X4-89 4-way in-line fl oodlight bracket X4-89-NSEW 4-way + shaped fl oodlight bracket sha shaped fl oodlight bracketped fl oodlight bracket Brackets to suit 114mm column with integral spigot Brackets to suit 114mm column with integral spigot X3-114 Triple in-line fl oodlight bracket X4-114 4-way in-line fl oodlight bracket Brackets to suit 140mm column with integral spigot Brackets to suit 140mm column with integral spigot X3-140 Triple in-line fl oodlight bracket X4-140 4-way in-line fl oodlight bracket 31 street and external lighting specialist
Bracketry X4NSEW STYLE 2 75 150 A FLOODLIGHT BRACKETS 2 POS 512 HOLE THRU CHANNEL TAP M16x2 - 6H 500 4 POS 75 150 11 11 4 POS 76x38x7 CHANNEL 500 76x38x7 CHANNEL PLATE 3 THICK 4 HOLES THRU 512 4 POS EQUISPACED RADIALLY HOLE Ø35 THRU PLATE FIT 4 M10x10 LONG TAP M10x1.5-6H A FLAT POINT SOCKET 500 500 SET SCREWS 1100 550 26 4 POS 100 TO SUIT COLUMN TUBE LENGTH 200 26 76x38x7 CHANNEL Other sizes and GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: confi gurations Parts 1 and 2 available, please All channel to be BS4: PART 1: 2005 ask for details All plates to be EN 10025: 1993: GRADE S275 J0 ask for details All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Column loadings Welders to be qualifi ed to BSEN 287-1: 2004 to be checked prior to installation if in doubt please ask Brackets to suit 76mm column shaft or spigot X4-89-NSEW 4-way + shaped fl oodlight bracket Brackets to suit 114mm column with integral spigot X4-114-NSEW 4-way + shaped fl oodlight bracket Brackets to suit 140mm column with integral spigot X4-140-NSEW 4-way + shaped fl oodlight bracket 32 street and external lighting specialist
Bracketry SPT STYLE 2 DISC Ø107 z3 TUBE 42 OD x 3 WALL z6 TOP HALF OF TUBE ONLY 1000 50 5º DISC 3 THICK z6 TUBE LENGTH 350 INSET 40 2 SETS OF 4 HOLES THRU EQUISPACED RADIALLY TAP M10x1.5-6H FIT 8M10x10 LONG FLAT POINT SOCKET SET SCREWS 30 100 TO SUIT COLUMN z3 z6 TOP HALF OF TUBE ONLY 2 POS DPT STYLE DISC Ø107 TUBE OD x 3 WALL 34mm - 60mm LANTERN BRACKETS DISC 3 THICK 50 0º Return 5º Tilt 2 SETS OF 4 HOLES THRU EQUISPACED RADIALLY TUBE LENGTH 350 INSET 40 TAP M10x1.5-6H FIT 8 M10x10 long FLAT POINT SOCKET 2 POS SET SCREWS GENERAL NOTES 30 100 All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 TO SUIT COLUMN All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 Brackets to suit 60mm post top column SPT1-500-42 Single side entry DPT1-500-42 Twin side entry Brackets to suit 76mm post top column SPT2-500-42 Single side entry DPT2-500-42 Twin side entry TPT2-500-42 Triple T shaped side entry QPT2-500-42 4-way + shaped side entry 33 street and external lighting specialist
Bracketry C2H STYLE 2 600 CRS 2 POS (521.4) POST TOP BRACKETS 2 POS (517.5) 2 POS B B 76.1 OD x 3 WALL TUBE DISC ø82 76.1 OD x 3 WALL TUBE 2 POS DISC 3 THICK z3 2 POS z5 2 POS HOLE 20 THRU 2 POS 50 2 POS 50x25x3 RHS 130 2 POS 105 2 POS 2 POS (50) 2 POS TUBE LENGTH 350 2 POS HOLE 20 THRU 2 POS 2POS z5 TUBE LENGTH 250 A z3 DISC 3 THICK 2 POS DISC 70 2 POS 2 POS GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 Twin brackets to suit post top or spigot style columns A B 89mm C2H 100mm 114mm 60mm & 76mm 140mm 34 street and external lighting specialist
Bracketry C3H STYLE 2 TUBE LENGTH 350 3 POS DISC Ø70 3 POS DISC 3 THICK 130 3 POS 3 POS B HOLE 20 THRU 3 POS z3 3 POS z5 3 POS 105 76.1 OD x3 WALL TUBE 3 POS 3 POS 600.0 CRS 3 POS (517.5) 3 POS (521.4) 3 POS 50x25x3 RHS 88.9 OD x 3 WALL TUBE HOLE 20 THRU 3 POS z5 3 POS 120º 120º 3 POS (50) 3 POS DISC 3 THICK A POST TOP BRACKETS TUBE LENGTH 250 DISC Ø82 50 z3 3 POS B B GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 Triple brackets to suit post top or spigot style columns A B 89mm C3H 100mm 114mm 60mm & 76mm 140mm 35 street and external lighting specialist
Bracketry C4H STYLE 2 TUBE LENGTH 350 76.1 OD x 3 WALLTUBE 4 POS DISC 3 THICK 4 POS 4 POS 130 POST TOP BRACKETS DISC 07 4 POS 4 POS B 105 HOLE 20 THRU 4 POS 4 POS 88.9 OD x 3 wall tube HOLE 20 THRU 4 POS 50x25x3 RHS 600 CRS 4 POS 600 CRS 4 POS (521.4) 4 POS 4 POS (50) 4 POS DISC 3 THICK B B A B z3 z5 DISC n 82 4 POS TUBE LENGTH 250 50 4 POS z5 4 POS B z3 4 POS GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 ed to BSEN 287-1: 2004 fiWelders to be quali Quad brackets to suit post top or spigot style columns A B 89mm C4H 100mm 114mm 60mm & 76mm 140mm 36 street and external lighting specialist
Bracketry X1 BOLT ON 2 300 76 1 HOLE DRILLED AND TAPPED M16 EXAMPLE MOUNTED ON POST BESPOKE BRACKETS GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 37 street and external lighting specialist
Bracketry WALL MOUNTED POST 2 76 TUBE BESPOKE BRACKETS 1000 HEIGHT 100 150 150 20MM HOLE 4 HOLES DRILLED M10 GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 38 street and external lighting specialist
Bracketry 60MM FLAT WALL S-E 2 300 60 MOVABLE PLATE A 1000 HEIGHT DRILLED AND TAPPED HOLE M10, ALLEN STUD SUPPLIED BESPOKE BRACKETS DETAIL A WELDED PLATE HOLES DRILLED M10 20MM CONDUIT HOLE DRILLED AND TAPPED 200 X 50 PLATE GENERAL NOTES All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 39 street and external lighting specialist
Bracketry OFF SET BRACKET 2 OUTREACH PLASTIC CAP BESPOKE BRACKETS OVERALL HEIGHT SHAFT DIAMETER OF EXISTING POST GENERAL NOTES TUBE All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 DIAMETER All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 40 street and external lighting specialist
Bracketry ANTI CLIMB BRACKET 2 25 x 5 FLAT BAR 4mm ROUND BAR 25 x 5 FLAT BAR 250 250 TO SUIT 76 TO SUIT 114 COLUMN SHAFT DIAMETER OR STRAIGHT POST 180 BESPOKE BRACKETS 25 x 5 FLAT BAR 25 x 5 4mm ROUND BAR FLAT BAR 250 250 TO SUIT 114 COLUMN SHAFT OR STRAIGHT POST TO SUIT 76 GENERAL NOTES DIAMETER All tubes to be from circular hollow section EN 10210: 2006: Parts 1 and 2 180 All RHS to be from rectangular hollow section EN 10210: 2006: Parts 1 and 2 All plates to be EN 10025: 1993: GRADE S275 J0 All burrs and sharp edges to be removed Welding to be carried out in accordance with WPS 00267 All other welding details to be in accordance with BSEN 1011-1 Welders to be qualifi ed to BSEN 287-1: 2004 41 street and external lighting specialist
Bracketry BEI offers a wide range of spigots/reducers from stock ranging from 34mm to 219mm. We offer either an internal or external fi t options in either a galvanised or 2 use existing columns for a variety of different mounting painted fi nish. These products enable customers to options. SPIGOTS Column Spigot Adaptor Internal Reducer 76mm - 60mm B 60mm 100mm 100mm Length 265mm Hole for allen screw xing Rubber gasket Drilled & Tapped 60mm Length M10 Holes A We are able to offer a tailor made bracket service. Contact BEI Column Spigot Adaptor A B 76mm 60mm 76mm 89mm 60mm 89mm 100mm 76mm 60mm 89mm 114mm 76mm 60mm 42 street and external lighting specialist
Bracketry BEI is able to offer a wide range of column barriers/protectors. These products help prevent damage to columns in exposed areas such as car parks. The products are available in a variety of sizes and formats and can be painted to your specifi c requirements. 2 C A COLUMN GUARDS B* BEI Column Guard A Overal height B* Distance from ground to fi rst rung *There will be an extra 300mm added for planting into the ground during manufacture C Diameter required (300/400/600mm) Available in Galvanised or Painted Finishes 43 street and external lighting specialist
Bracketry VISIRAIL 2000MM HIGH VISIBILITY GUARDRAIL PANEL 2000 2 Design Panel design and construction to BS 7818:1995 Standard Finishes 900 i) Hot Dip Galvanised to BS EN ISO 1461:2009 1300 70 x 8 FLAT RAILS GL ii) Hot Dip Galvanised and Polyester GUARDRAILS V2 Inll Optimum Sight Angle 2.5º to 5º Powder Coated ii) Hot Dip Galvanised and Fully Painted 12SQ BAR INFILL V4 Inll Optimum Sight Angle 5º to 14º V8 Inll Optimum Sight Angle More Than 14º 2000 Cantilever Panels VISIFLEX 2000MM HIGH VISIBILITY GUARDRAIL PANEL for transparency and resilience Pivot Joints 900 for transparency and resilience 1300 Stub Posts for damage resistance and ease of repair Connected by high-strength, stainless 100 Ø12 BAR INFILL GL steel bolts, these create a portal frame/ 50 x 30 R.H.S RAILS Ø48.3 C.H.S STUB POST torsion box structure in galvanized steel to eliminate the need for full-length posts. V4 Inll VISIFLEX VISIFLEX PIVOT JOINT VISIRAIL 44 street and external lighting specialist
Bracketry BEI 2000MM UNIT GUARDRAIL PANEL 2000 Design Panel design and construction to 2 BS 7818:1995 Standard Finishes 940 i) Hot Dip Galvanised to 1372 BS EN ISO 1461:2009 GUARDRAILS ii) Hot Dip Galvanised and Polyester Powder Coated ii) Hot Dip Galvanised and Fully Painted Ø12 BAR INFILL GL 50 x 30 R.H.S FRAME Standard Inll Staggered Inll BEI 2000MM UNIT GUARDRAIL PANEL WITH SIGHT GAP 2000 940 1372 Ø12 BAR INFILL GL 50 x 30 R.H.S FRAME Standard Inll Staggered Inll BEI offers a comprehensive range of pedestrian guard rail from stock. We use one of the UK’s leading manufacturers of pedestrian guardrail, fully designed to BS7818 or BD52/93 for parapet. We stock several variations of standard panels for ex-stock delivery. We can also supply job specifi c panels to meet exactly with your specifi c requirements. All of our products are galvanised and can be supplied with additional protective coating systems such as powder coating or wet fi lm applied paints using the latest technology and meeting the specifi cation for Highway Works. 45 street and external lighting specialist
AMENITY LIGHTING BEI can offer a wide range of amenity lighting, including globes and capped spheres. We can offer various design options for Urban, Car Park lighting and Public Area lighting. 3 Complete with tailor made bracketry this range is complemented with bulkheads and bollards. 46 street and external lighting specialist
3 47 street and external lighting specialist
GLOBE IP54 post top fi tting for SON, HQI and 42W PL lamps. 48 street and external lighting specialist
Amenity APPLICATIONS Parks and gardens & urban amenity areas SPECIFICATION Supplied with premium brand lamp in wattages as listed 3 CONSTRUCTION Supplied as 2 items 1. Gallery assembly, comprising gallery, cover pipe, louvre, gear (remote on 150W) and lamp 2. Globe, Polycarbonate Clear Base Black Top Sphere GEAR BASE TO SUIT 76MM POST TOP COLUMN BEI CODE DESCRIPTION BEI/GB/70SON-E-I/76 70W SON-E /I\ Globe Gear Base c/w lamp BEI/GB/70HQI-E/76 70W HQI-E Globe Gear Base c/w lamp BEI/GB/100HQI-E/76 100W HQI-E Globe Gear Base c/w lamp BEI/GB/150HQI-E/76 150W HQI-E Globe Gear Base c/w lamp BEI/GB/42-PLT/76 42W PLT Globe Gear Base c/w lamp GLOBE BEI/GS/400/PC/CL/BT 400mm Polycarb Clear Base Black Top Sphere BEI/GS/450/PC/CL/BT 450mm Polycarb Clear Base Black Top Sphere BEI/GS/500/PC/CL/BT 500mm Polycarb Clear Base Black Top Sphere Both items above will be required for a complete lantern ø400, ø450 or ø500 0.2m 2 70W/100W 150W 42W ø400 = 497 ø450 = 547 4.5Kg 2.7Kg 2.9Kg ø500 = 597 49 street and external lighting specialist
HOLYHEAD The Holyhead is a traditional IP65 rated LED Post Top with a 360° light distribution. Manufactured with high pressure die-cast aluminium and a prismatic diffuser for a controlled distribution of light. 50 street and external lighting specialist
Search
Read the Text Version
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 76
- 77
- 78
- 79
- 80
- 81
- 82
- 83
- 84
- 85
- 86
- 87
- 88
- 89
- 90
- 91
- 92
- 93
- 94
- 95
- 96
- 97
- 98
- 99
- 100
- 101
- 102
- 103
- 104
- 105
- 106
- 107
- 108
- 109
- 110
- 111
- 112
- 113
- 114
- 115
- 116
- 117
- 118
- 119
- 120
- 121
- 122
- 123
- 124
- 125
- 126
- 127
- 128
- 129
- 130
- 131
- 132
- 133
- 134
- 135
- 136
- 137
- 138
- 139
- 140
- 141
- 142
- 143
- 144
- 145
- 146
- 147
- 148
- 149
- 150
- 151
- 152
- 153
- 154
- 155
- 156
- 157
- 158
- 159
- 160
- 161
- 162
- 163
- 164
- 165
- 166
- 167
- 168
- 169
- 170
- 171
- 172
- 173
- 174
- 175
- 176
- 177
- 178
- 179
- 180
- 181
- 182
- 183
- 184
- 185
- 186
- 187
- 188
- 189
- 190
- 191
- 192