FLUID FLOW AND LIQUID LEVEL SWITCHES LIQUID LEVEL PUMP UP/PUMP DOWN CONTROLLERS PUMP EMERGENCY SHUT DOWN CONTROLLERS WETTED MATERIALS BRASS, STAINLESS STEEL, HASTELLOY C., TITANIUM, TANTALUM, NORYL, FORTRON, TEFLON, HYPALON, EPDM, VITONHARWIL® 541 Kinetic Drive Phone: (805) 988-6800 Oxnard, CA 93030 Fax: (805) 988-6804 www.harwil.com Email: [email protected] 10-8-15
10-8-15
OPERATIONAL INFORMATIONWe DO NOT use multiple choice menu driven voice mail in response to your important telephone call.WE ANSWER THE TELEPHONE with actual human beings experienced in taking your order for standard products or provid-ing technical application assistance.Our PERSON TO PERSON order desk is open 7:30 am to 4:00 PM (PST), Monday through Friday.Our voice mail is on at all other times. We WILL respond to your important message at the beginning of our next businessday.Our FAX machine is never turned off. (805) 988-6804 TECHNICAL APPLICATION ASSISTANCEIn depth technical information to help you select the optimum HARWIL product for your particular application is as close asyour telephone and fax machine. • PHONE: (805) 988-6800, FAX (805) 988-6804 • We can modify standard units for special applications. • We also design and manufacture completely new models for O.E.M. applications. EMERGENCY DELIVERIESOur 50 year history of supplying support items such as level controllers, fluid flow and liquid level switches to a broadspectrum of industries has “burned” into our collective brains the importance of fast delivery of emergency orders to keepour customers “on line.” To this end we: • Attempt to keep reasonable numbers of all standard models in stock, i.e. physically on our “emergency shelf” for instantaneous delivery of small orders. • We have shipped orders received by 9:00 AM local time that same day. ORIGIN OF PRODUCTS99% of the products listed in this catalog are conceived, designed, developed, manufactured and marketed by HARWILCorporation. The exception in the current catalog is The Intrinsically Safe Relay which is a product of Warrick Controls, Inc.(USA) BACKGROUNDHARWIL Corporation was formed in 1956. Electromechanical fluid flow and liquid level switches were one of our initialproduct lines and are now the major product line. Current development is directed toward electronic and electro-optical flowand level switches and controls. TRADEMARKSViton is a registered trademark of DuPont performance Elastomers. i 10-8-15
TABLE OF CONTENTSFLOW SWITCHESModel Process Pipe Size Flow Range Chemical Max. Max. Electrical Page Q-1 Connection ½” (GPM) Resistant Working Working Switch Page 0.12–8 Pressure ½” NPT 4–70 Temp SPDT 15A or 180˚F (82˚C) 300 psi Dry CircuitQ-4E 1” NPT 1” 5–85,000+ 10–102,000+ 180˚F (82˚C) 300 psi SPDT 15A orQ-5 1” NPT 1–48” Dry Circuit 8–1,900+ 180˚F (82˚C) 300 psiQ-5SS 1” NPT 1–48” 8–1,900+ SPDT 15A or 0.9–1,025 180˚F (82˚C) 300 psi Dry CircuitQ-8N 1” NPT 1–10” 0.9–1,025 180˚F (82˚C) 50 psi SPDT 15A orQ-8CR 1” NPT 1–10” 0.4–590 Dry Circuit 200˚F (93˚C) 50 psiQ-10N 1” NPT 1–16” 0.4–590 SPDT 15A or 180˚F (82˚C) 200 psi Dry Circuit 4–500 SPDT 15A or Dry Circuit SPNO 0.5AQ-10VCR 1” NPT 1–16” 200˚F (93˚C) 250 psi SPNO 0.5A Q-12N 1–16” Q-12CR ½” NPT, 1–16” 180˚F (82˚C) 200 psi SPNO 0.5A Q-16 ¾\" NPT 1–6” ½” NPT, 200˚F (93˚C) 250 psi SPNO 0.5A ¾\" NPT 250˚F (121˚C) 200 psi SPDT 15A or 1” NPT Dry CircuitLEVEL SWITCHES Model Process On/Off Specific Chemical Max. Max. Electrical L-5 Connection Liquid Gravity Resistant Working Working Switch Differential Pressure L-5SS 1\" NPT Temp SPDT 15A or L-8N 1\" NPT ≈ ¼” Cont. adjustable 180˚F (82˚C) 300 psi Dry Circuit L-8CR 1\" NPT ≈ ¼” 0.6 Minimum L-21N 1\" NPT ≈ ¼” 180˚F (82˚C) 300 psi SPDT 15A orL-21VCR 1¼\" NPT ≈ ¼” Cont. adjustable Dry Circuit L-30N 1¼\" NPT 0.6 Minimum 180˚F (82˚C) 75 psiL-30CR 1\" NPT ≈ ¼” SPDT 15A or 1\" NPT ≈ ¼” Cont. adjustable 200˚F (93˚C) 75 psi Dry Circuit L-40N 0.6 Minimum 180˚F (82˚C) 200 psi SPDT 15A or Cont. adjustable Dry Circuit 0.6 Minimum SPDT 11A Cont. adjustable 0.7 Minimum 200˚F (93˚C) 250 psi SPDT 11A 180˚F (82˚C) 75 psi Cont. adjustable 200˚F (93˚C) 100 psi SPDT 15A or 0.7 Minimum 180˚F (82˚C) 200 psi Dry Circuit Cont. adjustable 200˚F (93˚C) 250 psi SPDT 15A or 0.8 Minimum Dry Circuit Cont. adjustable SPST or SPDT, 0.7 Minimum 50 or 100 watt ¼\" NPT ≈ ¼” Cont. adjustable 0.7 Minimum SPST or SPDT, 50 or 100L-40VCR ¼\" NPT ≈ ¼” Cont. adjustable watt 0.7 Minimum ii 10-8-15
TABLE OF CONTENTSCONTROLLERS Model Type Features Page L-21N, Single point rigid float liquid level pump up/pump 1\", 2\", 3\", or 5\" pump up/pump down differential PageL-21 VCR down module. i Stand-alone interface module automatically actuates a ivCF-112N Chemical feed pump interface module chemical feed pump when primary bulk fluid begins to flow. vCF-112CR Chemical feed pump interface module Stand-alone interface module automatically actuates a 36 chemical feed pump when primary bulk fluid begins to flow. 37LC-1 2 point pump up/pump down module Any 2 Harwil level switches can be combined with the LC-1 toSDC-101 Pump automatic shut-down control module provide infinitely variable level differential. S-27 Intrinsically safe solid-state relay for use in Monitors output of pump and shuts pump off if flow is below hazardous areas set point. Allows all Harwil flow and level switches to be used in Class I, II, and III hazardous areas.APPENDICES Title DescriptionOPERATIONAL INFORMATIONPRODUCT/COMPONENT BILLING & RETURN TERMSWARRANTYEPOXY AND PTFE COATINGS OF FLUID FLOW ANDLIQUID LEVEL SWITCHESCHEMICAL RESISTANCE CHART FOR VARIOUS PUMPMATERIALS iii 10-8-15
HARWIL CORPORATION PRODUCT/COMPONENT BILLING & RETURN TERMSOwnership of all products and components is transferred rating. Collection fees and related costs will be added to thefrom Harwil to the purchasing entity at the time and place original invoice plus other charges as listed above.of initial delivery of subject products and components to thetransporting carrier (UPS, USPS, or FedEx) Harwil will make We appreciate your interest in our products and strive toits best effort to follow up, monitor, and trace shipment of all provide you with dependable products that satisfy youritems indicated above, but cannot guarantee delivery and requirements. We do not have the financial resources to actcannot assume any liability for any damages, labor costs or as a bank or lending institution to companies that do not paydelays incidental thereto. their invoices in a timely manner. If you experience payment difficulties, we will be happy to work with you to arrangeNon-Credit Terms – Cash, C.O.D. or VISA / MasterCard a mutually satisfactory payment schedule. To do so, please contact Accounts Receivable by phone at (805) 988-6800Credit Terms – Net 30 days on approved credit or by fax (805) 988-6804.Credit Approval – Allow 2 WEEKS for approvalF.O.B. – Oxnard, CAInvoices will be dated the day of shipment. All accountsare due and payable in terms stated on the invoice.Claims: If product and/or component shortage, breakageor discrepancy is found, advise us at once in writing. Noclaims honored after 20 days from date of shipment.Returns: No credit will be allowed for goods returnedwithout an approved material return authorization (MRA)number.A restocking fee of 20% will be charged for merchandisereturned unused and in good condition.Finance Charges: After 30 days, a finance charge of1.5% (18% per annum) will be charged on all past-dueaccounts. A reminder statement will be sent after an accountis 60 days past due. After 90 days, a second statementwill be sent, incurring a $5.00 follow-up service charge. Alladditional statements and telephone calls will be billed at$5.00 each.Delinquent Invoices: An overdue invoice (60 days ormore) or exceeding written credit limit will require holdingdelivery of current and future purchase orders until either orboth conditions are corrected. An invoice that is 90 daysdelinquent will be mailed a final 10 day notice. Responserequires payment or contact with our accounting depart-ment for special payment arrangements. If we receive noresponse, Harwil will assume the customer does not intendto honor the debt and the account will be turned over toour collection agency, which could effect subject credit iv 10-8-15
CERTIFICATE OF CONFORMANCEAll Harwil Corporation (“HARWIL”) products are specifications indicated in our current Specifications Sheetsmanufactured using new materials and components. Our and Parts List. HARWIL endeavors to obtain its materialsproducts meet the applicable performance and materials and components from American Companies.DOMINANCE OF HARWIL LIMITED EXPRESS WARRANTYEach user MUST make appropriate analysis and tests to solely for general background information. This informationdetermine the suitability of the HARWIL product for the table has been compiled from literature published by variousintended use prior to purchase. material suppliers and by equipment manufacturers who use these materials in their products. Inasmuch as theseHARWIL warrants that all HARWIL products will be free data are based on tests by entities over which HARWIL hasfrom defects in material and workmanship for a period of no control, HARWIL DOES NOT GUARANTEE AND DOESone year from the date of original shipment. This Warranty NOT ACCEPT ANY RESPONSIBILITY FOR THE ACCURACYshall be LIMITED to the replacement and reconditioning of OF SUCH THIRD PARTY TESTING. When using the table,our products and parts. HARWIL reserves the right and sole please remember that in any given case several factorsdiscretion to modify or change the composition, design and such as concentration, temperature, degrees of agitationappearance of its products at anytime. and presence of impurities influence the rate of corrosion. The information table is intended, in a general way, to rateTHIS WARRANTY SHALL BE IN LIEU OF ALL WARRAN- materials for resistance to chemicals which contain theirTIES OF MERCHANTABILITY AND OF ALL WARRANTIES usual impurities and for types of equipment in commonOF FITNESS FOR A PARTICULAR PURPOSE RELATING TO use. Ratings should be used only as a general tool to firstHARWIL PRODUCTS AND PARTS. BUYER’S SOLE REMEDY approximation of your material requirements rather than asSHALL BE REPLACEMENT OR RECONDITIONING AS SET the final answer.FORTH HEREIN. • When in doubt, test materialsHARWIL SHALL INCUR NO OBLIGATIONS HEREUNDER before installation.AND NO LIABILITY IN THE EVENT OF (1) BUYER NOTFULFILLING ITS RESPONSIBILITIES; INCLUDING AS SET • After installation, follow up withFORTH HEREIN; (2) NEGLECT, ALTERATION OR IMPROPER preventative maintenance andPRODUCT USE, INCLUDING USE WITH NON-COMPATIBLE periodic inspection.DEVICES OR CHEMICALS; OR (3) REPAIR BY ANOTHERCOMPANY OR PERSON THAN HARWIL.ANY LAWSUIT RELATING TO THIS LIMITED EXPRESSWARRANTY MUST BE COMMENCED WITHIN ONE YEAROF THE DATE THE LAWSUIT ACCRUES.HARWIL provides NO WARRANTY and ASSUMES NORESPONSIBILITY for corrosive attack on any material,component or design features associated with any of itsproducts.Corrosion resistance information listed in HARWIL specifica-tion sheets, information sheets and product brochures is v 10-8-15
FLOW SWITCH MODEL Q-1Designed for extreme, long-term reliability. KEY FEATURES NON- Flow Range MAGNETICDetects and signals flow change. Working Temp Working Pressure 0.12–8 GPM (0.45– 30.4 L/m)Continuously adjustable while in operation. Process Connection 32˚–180˚F (0˚–82˚C) Electrical Switch 300 psig (2,068 kPa)6 interchangeable orifices plus 2:1 continuous switch adjustment with ½\" NPTeach orifice. SPDT 15A or Dry CircuitCalibrated independent of line pressure and temperature. TYPICAL USESMaintains calibration limits when subjected to reasonable line hydraulic Monitoring flow of coolants and fluids supplied to:hammer or surge pulses.Super-simple maintenance and checkout forpersonnel using a standard test meter.Model Q-1 can also be fitted with a SPDTgold cross-bar switch for computer/PLCinterface.DPDT model available per request. Air Conditioning Systems Plastic Molding Equipment Cooling in Data Centers Scrubbers Diodes, SCRs, Triacs, etc. Spot Welders High Power Transistors Transformers Fluid Blending Systems Vacuum Systems Other Uses: Starting Back-up Pumps Oil Supply to Bearing & Gear Systems Monitor Filter Clogging Metal Fabrication Systems TYPICAL WORKING FLUIDS Filtered Sewage Water Oils Glycols Potable Water HydrocarbonsPRODUCT DIAGRAM RUGGED NORYL COVER CONTINUOUS SWITCH PATENTED MOLDED ELASTOMER POINT ADJUSTMENT FEEDTHRU SEALSPDT 15A SWITCH MODEL OR WATER/OIL RESISTANT DRY CIRCUIT COMPUTER/PLC PVC COVER SEAL INTERFACE MODEL 2D TURBULENT STAINLESS STEEL ADJUSTING SPRING 5D FLOW REDUCTIONREMOVE COVER AND LID ONLY FOR CALIBRATED ORIFICE 1 THRU 6 MOUNT IN QUICK ORIFICE CHANGE WITHOUT WEIGHT: 3.5 lb ANY POSITION REMOVING BODY FROM LINE 1.59 kg Phone: (805) 988-6800 Fax: (805) 988-6804HIGH-PRESSURE, MINIMUM-FRICTION 2 ROLLING DIAPHRAGM Email: [email protected] 10-8-15 O-RING SEALHARWIL® 541 Kinetic Drive Oxnard, CA 93030 www.harwil.com
MODEL SELECTION CHART MODEL Q-1Flow Range (Water calibrated at 70˚F / 21˚C)ORIFICE # CONTINUOUS SWITCH POINT ADJUSTMENT RANGE 1 0.12 to 0.25 GPM 2 0.25 to 0.50 GPM TECHNICAL SPECIFICATIONS 3 0.50 to 1 GPM 4 1 to 2 GPM 5 2 to 4 GPM HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH) 6 4 to 8 GPM ≈ 5% at upper end of flow range ≈ 25% at lower end of flow rangeNote: Maximum recommended flow rate for each orifice is four (4) times the upper-end of the adjustment range. DIFFERENTIAL PRESSURE DROPS ACROSS UNIT Under normal operating conditions: ELECTRICAL CONNECTION ≈ 1.0 psig at upper end of flow rangeGROMMET CABLE O.D. DIAGRAM ≈ 5.0 psig at lower end of flow range A AA 0.25” O.D. WORKING LINE PRESSURE WORKING TEMPERATURE B 0.30” 300 psi max. C 0.37” 180˚F max. 0.50” (250˚F model available) WETTED MATERIALS CONDUIT FITTINGS Body: Red brass 316 stainless steel, phosphor Hardware: Noryl (PPO) (10% glass bronze, and EPDM elastomer seal fibers), 316 stainless steel, Plastic Gasket: Cork/Nitrile blend Working fluid “sees” red brass, Optional Seal: Hypalon, VitonF 0.5” F90˚ 0.5” 90˚ ELECTRICAL SWITCH CHARACTERISTICS straight SPDT 10,000,000 operations, median 15A, ½ hp @ 125 or 250VAC (Switch may be overloaded to 20A ½A @ 125VDC, ¼A @ 250VDC @ 125 or 250VAC for a minimum 5A @ 125VAC (tungsten lamp of 20,000 operations.) load)SAMPLE PART NUMBERS OPTION 1: Q-1 / 3 / A OPTION 2: Q-1 / 6 / F BASE MODEL ↑ ↑ BASE MODEL ↑ ↑ ORIFICE ORIFICE GROMMET SIZE ½\" FLEXIBLE CONDUIT FITTINGINSTALLATION DIMENSIONS SIDE VIEW FRONT VIEW TOP VIEW 3 ELECTRICAL CABLE FITTING PER OPTION 1 OR 2 10-8-15 • Installation drawing and a numbered parts list is supplied with each unit. • Special one-day delivery is available.
FLOW SWITCH MODEL Q-4EDesigned for NON-extreme, long-term MAGNETICreliability. 4–70 GPM (15.14–265 L/m)Detects and signals KEY FEATURES 32˚–180˚F (0˚–82˚C)flow change. Flow Range 300 psig (2,068 kPa) Working Temp 1\" NPTContinuously Working Pressure SPDT 15A or Dry Circuitadjustable while Process Connectionin operation. Electrical SwitchFour (4) individualPaddle options plus con-tinuous adjustment provideswide operating range.For use in particle contami- TYPICAL USESnated fluids.Maintains calibration limits when lic Monitoring flow of coolants and fluids supplied to:subjected to reasonable line hydrau-hammer or surge pulses. Air Conditioning Systems Plastic Molding Equipment Cooling in Data Centers ScrubbersSuper-simple maintenance and checkout for personnel using a standard Diodes, SCRs, Triacs, etc. Spot Welderstest meter. Fluid Blending Systems Transformers High Power Transistors Vacuum SystemsDPDT model available per request. Other Uses: Monitor Filter Clogging Starting Back-up Pumps Fire Sprinkler Flow Alarms TYPICAL WORKING FLUIDS Glycols Oils Hydrocarbons Potable WaterPRODUCT DIAGRAM SPDT, 15A SWITCH MODEL OR NEMA 4 COVER MODELS Q-4E/2, 3, AND 4 USE DRAG DRY CIRCUIT COMPUTER/PLC DISK ONLY INTERFACE MODEL CONTINUOUS SWITCH-POINT RUGGED ADJUSTMENT NORYL COVER REMOVE COVER AND LID ONLY FOR WATER/OIL QUICK ORIFICE CHANGE RESISTANT WITHOUT REMOVING BODY PVC FROM LINE COVER SEAL DRAG DISK WATER/OIL STAINLESS ADJUSTING SPRING 2D TURBULENT RESISTANT 5D FLOW REDUCTION ELECTRICAL PATENTED, MOLDED ELASTOMER CABLE STRAIN FEED-THRU SEAL MOUNT IN RELIEF (OPTION ORIFICE ANY POSITION 1 OR 2) WEIGHT: 5 lb Phone: (805) 988-6800 O-RING SEAL 2.27 kg Fax: (805) 988-6804HARWIL® 541 Kinetic Drive 4 Email: [email protected] Oxnard, CA 93030 www.harwil.com 10-8-15
MODEL SELECTION CHART MODEL Q-4EFlow Range (Water calibrated at 70˚F / 21˚C)ORIFICE/ CONTINUOUS SWITCH POINT ADJUSTMENTPADDLE # RANGE 1 4 to 8 GPM HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH) 2 6 to 20 GPM ≈ 5% at upper end of flow range ≈ 25% at lower end of flow range 3 15 to 35 GPM 4 25 to 70 GPMNote: Model Q-4E/1 uses a #1 orifice and a #4 paddle. Models Q-4E/2, 3,and 4 use paddle only. ELECTRICAL CONNECTION DIFFERENTIAL PRESSURE DROPS ACROSS UNIT Under normal operating conditions:GROMMET CABLE O.D. DIAGRAM A 0.25” ≈ 1.0 psig at upper end of flow range AA 0.30” O.D. ≈ 5.0 psig at lower end of flow range B 0.37” C 0.50” WORKING LINE PRESSURE WORKING TEMPERATURE 300 psig max. @ 180˚F max 180˚F max. (May be extended to (Proof tested to 1,200 psi @ 70˚F) 200˚F for short periods.) CONDUIT FITTINGS WETTED MATERIALS Body: Red brass 316 stainless steel, phosphorF 0.5” F90˚ 0.5” Hardware: Noryl (PPO) (10% glass bronze, and EPDM Elastomer Seal straight 90˚ fibers), 316 stainless steel, Plastic Gasket: Cork/Nitrile blend Working fluid \"sees\" red brass, Optional Seal: Hypalon, Viton ELECTRICAL SWITCH CHARACTERISTICSSAMPLE PART NUMBERS OPTION 2: Q-4E / 3 / F SPDT 10,000,000 Operations Median OPTION 1: Q-4E / 1 / B BASE MODEL ↑ ↑ 15A, ½ hp @ 125 or 250VAC Switch may be overloaded to 20A BASE MODEL ↑ ↑ ORIFICE/PADDLE # ½A @ 125VDC, ¼A @ 250VDC @ 125 or 250VAC for a minimum ORIFICE/PADDLE # 5A @ 125VAC (tungsten lamp of 20,000 operations. GROMMET SIZE ½\" FLEXIBLE CONDUIT FITTING load) Model Q-4E can also be fitted with a SPDT Gold Cross Bar Switch for computer/PLC interface.INSTALLATION DIMENSIONS SIDE VIEW FRONT VIEW TOP VIEW OPTION 1 OR 2 1” NPT 5 10-8-15
FLOW SWITCH MODEL Q-5 Q-5SSDesigned for extreme, long-termreliability. KEY FEATURES 5–102,000+ GPM (18.9–386.1 kL/m) Flow Range 32˚–180˚F (0˚–82˚C)Detects and signals flow change. Working Temp 300 psig (2,068 kPa) Working Pressure 1\" NPTContinuously adjustable while in Process Connection SPDT 15A or Dry Circuitoperation. Electrical SwitchFor use in particle contaminated TYPICAL USESfluids. Monitoring flow of coolants and fluids supplied to:Multiple quick change paddles (andcontinuous spring adjustment) provide Air Conditioning Systems Plastic Molding Equipmentan incredibly wide operating range of Boilers Scrubbersflow rates and viscosities. Cooling in Data Centers Spot Welders Diodes, SCRs, Triacs, etc. TransformersUse with an intrinsically safe relay allows Model Fluid Blending Systems Vacuum SystemsQ-5 to be used in hazardous areas. High Power TransistorsMaintains calibration limits when subjected toreasonable line hydraulic hammer or surge pulses.Calibrated independent of line pressure andtemperature.DPDT model available per request.SAMPLE PART NUMBERSOPTION 1: Q-5 / 3 / 2 / B OPTION 2: Q-5 / 3 / 2 / F Other Uses:BASE MODEL ↑ ↑ ↑ BASE MODEL ↑ ↑ ↑ Fire Sprinkler Flow Alarms Municipal Water Supply Systems Oil Supply to Bearing & Gear SystemsPIVOT SHAFT PIVOT SHAFT PADDLE # PADDLE # TYPICAL WORKING FLUIDSGROMMET SIZE ½\" FLEXIBLE CONDUIT FITTING Filtered Sewage Water Glycols Hydrocarbons Potable WaterPRODUCT DIAGRAM CONTINUOUS SWITCH POINT PADDLE (PADDLE/STRIP) NUMBER ADJUSTMENTCOLOR-CODED NO. 1: 0.5” DIA NO. 2: 0.9” DIAWIRING REMOVE COVER AND LID ONLY FOR ALL PIPE SIZES ALL PIPE SIZES QUICK DRAG DISK CHANGE WITHOUTRUGGED NORYL REMOVING BODY FROM LINE NO. 3: 0.94 x 1.4”COVER 1½” PIPES AND LARGER STAINLESS ADJUSTING SPRINGSPDT 15A (NOT SHOWN) NO. 4: 0.9” x 2.0”SWITCH MODEL 2\" PIPES AND LARGEROR DRY CIRCUIT MOLDED EPDM OR PATENTED, MOLDEDCOMPUTER/PLC FEED-THRU PIVOT SEAL NO. 5: 0.9” x 4.0”INTERFACE (Q-5SS PATENTED MOLDED VITON SEAL) 5\" PIPES AND LARGERMODEL RED BRASS OR 316 STAINLESS STEEL BODY AND LID NO. 6: 0.9” x 6.0”WATER/OIL RESISTANT 6\" PIPES AND LARGERELECTRICAL CABLE QUICK CHANGE DRAG DISKSTRAIN RELIEF 2D TURBULENT 5D FLOW REDUCTIONWATER/OIL RESISTANTPVC COVER SEALVARIABLE FEED-THRU PIVOT SHAFT WEIGHT: 3.5 lb. MOUNT INLENGTH ALLOWS FOR USE IN 1”–48” OR MORE 1.59 kg ANY POSITIONHARWIL® 541 Kinetic Drive 6 Phone: (805) 988-6800 Oxnard, CA 93030 Fax: (805) 988-6804 www.harwil.com 10-8-15 Email: [email protected]
MODEL SELECTION CHART MODEL Q-5 Q-5SSFlow Range (Water calibrated at 70˚F / 21˚C)PIPE SIZE CONTINUOUS SWITCH PIVOT PADDLE TECHNICAL SPECIFICATIONS NPT POINT ADJUSTMENT SHAFT # # RANGE (GPM) Red Brass 316 Stainless Steel HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH)1\" 5 to 15 10 to 20 2 2 ≈ 10% at upper end of flow range 1 ≈ 30% at lower end of flow range 12 to 36 20 to 60 2 DIFFERENTIAL PRESSURE DROPS ACROSS UNIT Under normal operating conditions: 14 to 42 21 to 63 3 42\" 20 to 60 30 to 90 3 2 ≈ 1\"–3\" pipe, less than 1 psi ≈ 4\"–48\" pipe, negligible 50 to 150 60 to 180 3 1 27 to 81 45 to 135 5 4 WORKING LINE PRESSURE: 300 psig max. @ 180˚F max (Proof tested to 1200 psig @ 70˚F)3\" 45 to 135 75 to 225 5 2 WORKING TEMPERATURE: 110 to 330 130 to 390 5 1 180˚F max. continuous. 65 to 195 103 to 309 5 6 ELECTRICAL SWITCH CHARACTERISTICS6\" 80 to 240 125 to 375 5 5 SPDT 10,000,000 Operations Median 2 15A, ½ hp @ 125 or 250VAC Switch may be overloaded to 20A 190 to 570 300 to 900 5 ½A @ 125VDC, ¼A @ 250VDC @ 125 or 250VAC (min 20,000 5A @ 125VAC (W lamp load) operations.) 450 to 1,350 550 to 1,650 5 1Call our customer support for a wider range of pipe sizes. (805) 988-6800 ELECTRICAL CONNECTIONGROMMET CABLE O.D. DIAGRAM Q-5N: WETTED MATERIALS: A AA 0.25” O.D. Body and Lid: Brass B 0.30” Hardware: Noryl (PPO) (10% glass fibers), 316 stainless steel C 0.37” Working fluid “sees” red brass, phosphor bronze and EPDM 0.50” elastomer seal Gasket: Cork/Nitrile blend Optional Seal: Hypalon, Viton CONDUIT FITTINGS Q-5SS: WETTED MATERIALS:F 0.5” straight F90˚ 0.5” 90˚ Body and Lid: 316 Stainless steel. Hardware: Noryl (PPO) (10% glass fibers), 316 stainless steel Working fluid “sees” 316 stainless, Teflon gasket and Viton elastomer seal.INSTALLATION DIMENSIONS SIDE VIEW FRONT VIEW TOP VIEW 1” NPT OPTION 1 OR 2Model Q-5 can also be fitted with a SPDT GoldCross Bar Switch for computer/PLC interface. • Installation drawing and a numbered parts list is supplied with each unit. 7 • Special one-day delivery is available. 10-8-15
FLOW SWITCH MODEL Q-8N Q-8CRADJUSTABLEDuring normal operations flow switches KEY FEATURES NON-increase efficiency, save time and money Flow Range MAGNETICby the continuous monitoring of deviations Working Tempfrom optimum flow rates. During 8–1,900+ GPM (30–7,192 L/m)emergency conditions flow switches Working Pressure 32˚–200˚F (0˚–93˚C)signal system malfunctions such as line 100 psig (690 kPa) @ 180˚F (N)breakage, pump failure, incorrect valve Process Connection 100 psig (690 kPa) @ 200˚F (CR)opening or closing, pipe, valve or filter Electrical Switch 1\" NPTclogging, etc. Enclosure SPDT, 1/2hp 15A or Dry CircuitDesigned for long-term reliability and NEMA 6P IP 67chemical resistance.Detects and signals flow change. TYPICAL USESParticle contamination resistance isprovided by a single convolute elastomeric Monitoring fluid flow in: Industrial Refrigeration Systemsseal which is continually flushed by working Pools and Spasfluid flow. Air Conditioning Systems ScrubbersContinuously adjustable while in operation. Cooling in Data Centers Water Treatment SystemsResponds to flow only, independent of line Chillerspressure, temperature, environment Fluid Blending SystemsSuper-simple maintenance and checkout for Natural Gaspersonnel using a standard test meter. TYPICAL WORKING FLUIDS PRODUCT DIAGRAM Filtered Sewage Water Contaminated Ground Water Mild Acids Sulfolane Rusty Coolant Water Sea Water Waste Water Pool Water (low ppm Chlorine) CORROSION RESISTANT FIBERGLASS SPRING ADJUSTMENT REINFORCED NORYL BODY AND COVER PERMEABLE GASKET1¼”–1” NORYL BUSHINGor 1½”–1” NORYL FILTER BOOT ADJUSTING SCREW CHAMBER FILLED WITH WORKING FLUID OF PIPE TO EQUALIZE PRESSURE DIFFERENTIAL PERMEABLE SHRINK TUBE SEAL DMP WATER/OIL RESISTANT 2D TURBULENT ELECTRICAL CABLE STRAIN 5D FLOW REDUCTION RELIEF OPTION 1 OR 2 SPDT 15A SWITCH MOUNT IN MODEL OR DRY NEMA 6 COVER ANY POSITION CIRCUIT COMPUTER/PLC INTERFACE MODEL WEIGHT: 0.5 lb. Phone: (805) 988-6800 0.23 kg Fax: (805) 988-6804HARWIL® 541 Kinetic Drive Oxnard, CA 93030 8 Email: [email protected] www.harwil.com 10-8-15
MODEL SELECTION CHART MODEL Q-8N Q-8CRFlow Range (Water calibrated at 70˚F / 21˚C)PIPE SIZE CONTINUOUS SWITCH SHAFT PADDLE TECHNICAL SPECIFICATIONS NPT POINT ADJUSTMENT LENGTH SIZE RANGE HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH) ≈ 10% at upper end of flow range 8 to 13 GPM 12 ≈ 30% at lower end of flow range1\" 11 DIFFERENTIAL PRESSURE DROPS ACROSS UNIT 18 to 28 GPM Under normal operating conditions: 15 to 50 GPM 23 ≈ 1\"–3\" pipe, less than 0.5 psi2\" 21 ≈ 4\"–10\" pipe, negligible 50 to 105 GPM WORKING LINE PRESSURE: 100 psi max. non-operating 40 to 90 GPM 33 Pressure over 50 psi can affect the switch point range.3\" 31 90 to 180 GPM 75 to 155 GPM 334” 31 155 to 310 GPM 180 to 350 GPM 33 ELECTRICAL SWITCH CHARACTERISTICS6\" 31 350 to 700 GPMCall our customer support for a wider range of pipe sizes. (805) 988-6800 SPDT 10,000,000 Operations Median 15A, ½ hp @ 125 or 250VAC ELECTRICAL CONNECTION ½A @ 125VDCGROMMET CABLE O.D. DIAGRAM (tungsten lamp load) A 0.25” O.D. AA 0.30” Model Q-8N can also be fitted with a SPDT Gold Cross Bar Switch for B 0.37” computer/PLC interface. C 0.50” Q-8N (NORYL)CONDUIT FITTINGS (AVAILABLE AT EXTRA COST) WORKING TEMPERATURE: 180˚F @ ambient pressure WETTED MATERIALS:F 0.5” straight F90˚ 0.5” Body, Cover, and Bushing: Noryl (PPO) (10% glass fibers) 90˚ Shaft: 316 stainless steel Elastomer Seal: EPDM Optional Filter Boot: EPDM (Viton available by special order)SAMPLE PART NUMBERS OPTION 2: Q-8N / 1 / 1 / F Q-8CR (FORTRON)OPTION 1: Q-8N / 1 / 1 / B BASE MODEL ↑ ↑ ↑ WORKING TEMPERATURE: 200˚F max. continuous SHAFT LENGTH WETTED MATERIALS: BASE MODEL ↑ ↑ ↑ PADDLE SIZE Body and Cover: Fortron (PPS) (40% glass fibers) SHAFT LENGTH ½\" FLEXIBLE CONDUIT FITTING Shaft: Hastelloy C PADDLE SIZE Elastomer Seal: EPDM GROMMET SIZE Optional Filter Boot: EPDM (Viton available by special order)INSTALLATION DIMENSIONS 1½” A/F HEXDRAG DISK ARM LENGTH Q-8N/1, X–1.15 Q-8N/2, X–1.85 Q-8N/3, X–3.31 X 2 ⁄ ” WIDTH 1¾”#1 - 0.5” ⁄” 3 ⁄”#2 - 0.83” ¼”#3 - 1.0” 4⁄”DRAG DISK SIZE • Installation drawing and a numbered parts list is 9 supplied with each unit. 10-8-15 • Special one-day delivery is available.
FLOW SWITCH MODEL Q-8DS DPDT Q-8DSDuring normal operations flow switchesincrease efficiency, save time and money by KEY FEATURES NON-the continuous monitoring of deviations Flow Range MAGNETICfrom optimum flow rates. During Working Tempemergency conditions flow switches Working Pressure 5 - 80 GPM (18–302 L/m)signal system malfunctions such as line Process Connection 32˚–180˚F (0˚–82˚C)breakage, pump failure, incorrect valve Electrical Switch 100 psig @ 180˚F (466˚F kPa)opening or closing, pipe, valve or filter Enclosure 1\" NPTclogging, etc. SPDT, 1/2hp 15A or Dry Circuit NEMA 6P IP 67Designed for long-term reliability andchemical resistance. TYPICAL USES Industrial Refrigeration Systems Pools and SpasDetects and signals flow change. Monitoring fluid flow in: Scrubbers Water Treatment SystemsResponds to flow only, independent Air Conditioning Systemsof line pressure, temperature, Cooling in Data Centersenvironment Chillers Fluid Blending SystemsSuper-simple maintenance and checkout Natural Gasfor personnel using a standard test meter. Q-8DS DPDT Now available • 11 Amp • 1/3 Hp TYPICAL WORKING FLUIDS Filtered Sewage Water Contaminated Ground Water Mild Acids Sulfolane Rusty Coolant Water Sea Water Waste Water Pool Water (low ppm Chlorine)PRODUCT DIAGRAM O-RING BODY, COMPLETE WITH COVER GROMMET ‘A’ FEED THRU SHAFT ASSEMBLY 4 RETAINING SCREWS GROMMET ‘AA’ (SEE PARTS LIST) (NOT SHOWN) GROMMET ‘B’ “F” COVER GROMMET ‘C’DO NOT ATTEMPT TO REMOVEDRAG STRIP WITHOUT FIRST STRAIN RELIEF NUTGRIPPING SEAL SHAFT TOPREVENT BREAKING OF SEALBY UNTHREADING FROM FEEDTHRU SHAFT. “F” COVER TO SUIT CUSTOMER SUPPLIED FITTING FOR ½” FLEXIBLE CONDUIT 2D TURBULENT 5D FLOW REDUCTIONDRAG STRIP SCREW x 7/8” LG MICROSWITCH COMPLETECLAMP WASHER NUT W/ 2 SLIP-ON TERMINALSDAMPENER WASHER PLAIN WASHERSCREW x 3/8” LG SPLIT LOCKWASHER SCREW x ¾” LG2 PLAIN WASHERS NUTSPLIT LOCKWASHER PLAIN WASHER SPLIT LOCKWASHER MOUNT INHARWIL® 541 Kinetic Drive WEIGHT: 0.5 lb. ANY POSITION Oxnard, CA 93030 0.23 kg www.harwil.com Phone: (805) 988-6800 10 Fax: (805) 988-6804 10-8-15 Email: [email protected]
MODEL SELECTION CHART MODEL Q-8DS DPDTFlow Range (Water calibrated at 70˚F / 21˚C) Accuracy ±10% Q-8DSPIPE SIZE NOMINAL ON/OFF SHAFT PADDLE TECHNICAL SPECIFICATIONS NPT SWITCH POINT RANGE LENGTH NUMBER 1\" HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH) (GPM) - 10512 ≈ 10% at upper end of flow range 1 ½” 5.0 - 3.0 1 2 ≈ 30% at lower end of flow range 9.6 - 7.5 1 1 2\" 15.4 - 18.0 - DIFFERENTIAL PRESSURE DROPS ACROSS UNIT 12.0 - 9.5 10502 Under normal operating conditions: 3\" 2 14.2 - 11.8 3 ≈ 1\"–3\" pipe, less than 0.5 psi - ≈ 4\"–10\" pipe, negligible 19.0 - 13.5 2 10570A WORKING LINE PRESSURE: 22.5 - 19.0 2 2 100 psi max. non-operating 34.4 - 30.4 - 1 Pressure over 50 psi can affect the switch point range. 14.4 - 10.2 - 16.5 - 11.0 2 10593 ELECTRICAL SWITCH CHARACTERISTICS 25.8 - 21.8 2 10566 39.8 - 33.6 2 SPDT 10,000,000 Operations Median 58.0 - 50.8 3 3 15A, ½ hp @ 125 or 250VAC 42.4 - 37.0 3 2 ½A @ 125VDC 55.6 - 49.8 1 3 (tungsten lamp load) 2 Model Q-8DS can also be fitted with a SPDT Gold Cross Bar Switch for computer/PLC interface or 25A micro switch. 80.6 - 65.2 31 Q-8DS (NORYL) WORKING TEMPERATURE: 180˚F @ ambient pressureCall our customer support for a wider range of pipe sizes. (805) 988-6800 WETTED MATERIALS: Body, Cover, and Bushing: Noryl (PPO) (10% glass fibers) ELECTRICAL CONNECTION Shaft: 316 stainless steel Elastomer Seal: VitonGROMMET CABLE O.D. DIAGRAM A 0.25” O.D. AA 0.30”B 0.37” SAMPLE PART NUMBERS OPTION 2: Q-8DS / 1 / 1 / FC 0.50” OPTION 1: Q-8DS / 1 / 1 / B BASE MODEL ↑ ↑ ↑ CONDUIT FITTINGS (AVAILABLE AT EXTRA COST) BASE MODEL ↑ ↑ ↑ SHAFT LENGTH SHAFT LENGTHF 0.5” straight F90˚ 0.5” 90˚ PADDLE SIZE PADDLE SIZE GROMMET SIZE ½\" FLEXIBLE CONDUIT FITTINGINSTALLATION DIMENSIONS 1½” A/F HEX 2 13/312/”3(21”½M”APXIPE) 1” NPT 15/16” 2 1/32 WIDTH 1¾ ¼” 3 1/8” • Installation drawing and a numbered parts list is 4 5/16” supplied with each unit. 11 • Special one-day delivery is available. 10-8-15
FLOW SWITCH MODEL Q-10N Q-10VCRFLEXIBLE DESIGN:Model Q-10 is provided with three factory adjustable parameters which KEY FEATURES 0.7–1,025 GPM (2.6–3,880 L/m)provide performance flexibility to meet a multitude of applications: Flow Range 32˚–200˚F (0˚– 93˚C) Working Temp 250 psig (1.724 kPa) • Paddle Area Working Pressure 1\" NPT • Paddle Length Process Connection SPNO 0.5A • Paddle Stiffness Electrical (Reed) SwitchResponds to fluid flow only, independent of line pressure and TYPICAL USEStemperature.Max. flow may be five times normal flow. Monitoring flow of coolant supplied to:Positive stop eliminates fatigue effects of turbulence, vibration and flowsurge on flow detecting element. Brakes and Clutches Emergency Wash-Down ShowersSmall size and low profile provides easy mounting in crowded Computer Systems Marine and Stationary Enginesinstallations. Diodes, SCRs, Triacs, etc. RF and Radar TransmittersVery low pressure drop - typically less than 1.0 psig at normal flow Electromagnets Spot weldersrate. Fire Sprinkler Flow Alarms TransformersQuick response. Lasers Vacuum SystemsAvailable with NO, NC or SPDT Reed SwitchSwitches 5VDC to 240VAC. In Chemical Processing:Switches resistive and light inductive loads.Switch employs magnetic coupling.Send us your special requirements. We will quote a special unit to meetthose requirements. Fluid Blending Systems Liquid Transfer Heat Transfer Fluids Monitor Filter Clogging Liquid Scrubbers Starting back-up pumps Monitoring pump output, valve position, systems flow status In Water Treatment: Irrigation Systems Municipal Water Supply Systems TYPICAL WORKING FLUIDS For use in concentrated acids, bases, ketones, esters, alcohols, phenols, etc. Mild Acids Hydrocarbons Mild Bases Ketones Plating Solutions Lubricating Oils Gasoline Cooling Tower Water Glycol Solutions Water (saltwater, pure, tap, etc.) JP-4 2D TURBULENT 5D FLOW REDUCTIONHARWIL® 541 Kinetic Drive 12 MOUNT IN Oxnard, CA 93030 ANY POSITION www.harwil.com 10-8-15 Phone: (805) 988-6800 Fax: (805) 988-6804 Email: [email protected]
MODEL SELECTION CHART Q-10N Q-10VCRFlow Range (Water calibrated at 70˚F / 21˚C) MODELPIPE SIZE NPT NOMINAL ON/OFF SWITCH PADDLE NUM- POINT RANGE (GPM) BER TECHNICAL SPECIFICATIONS ON OFF 1.3 0.9 1 ELECTRICAL (REED) SWITCH CHARACTERISTICS1\" 2 SPNO 42 3 2 10691A Contact Ratings: AC Voltage (max. switching) 300VAC1½\" 8 4 3 DC Voltage (max. switching) 350VDC 17 14 4 Current (max. switching) 0.5A 5 4 10691A Current (max. carrying) 2.5A Power (max) (VA, W) 50 watts2\" 10 7 5 Contact resistance (max. initial) 0.15 ohms 16 11 6 Insulation resistance 1010 ohms Operating temperature -40°F–240°F (-40°C–115°C) 12 8 10691A OPTIONAL: SPNC or SPDT, 3 watt, 100VAC/VDC.3\" 22 15 7 Q-10N (NORYL) WORKING PRESSURE: 200 psig max. @ 70˚F 36 25 8 WORKING TEMPERATURE: 180˚F @ ambient pressure WETTED MATERIALS: Body and Cover: Noryl (PPO) (10% glass 21 14 10691A fibers) Shaft: 316 stainless steel4\" 39 27 9 64 45 10 33 25 10691A Q-10VCR (FORTRON) WORKING PRESSURE: 250 psig max. @ 70˚F5\" 61 43 11 WORKING TEMPERATURE: 200˚F @ ambient pressure WETTED MATERIALS: Body and Cover: Noryl (PPS) (40% glass 100 70 12 fibers) Shaft: 316 Hastelloy C 48 35 10691A INDUCTIVE LOADS6\" 88 62 13 Switch contacts have been tested with small relays and 30A J-C relay inductive driving coils at 120/240VAC to 500,000 operations without 144 101 14 failure.Call our customer support for a wider range of pipe sizes. (805) 988-6800 Model Q-10N can also be fitted with a SPDT Gold Cross Bar Switch for computer/PLC interface.SAMPLE PART NUMBER OPTION 1: Q-10N / 13 / NO / 4' NOTE: Model Q-10N employs magnetic coupling between bending BASE MODEL ↑ ↑ ↑ blade and switch body. Magnetic particles can accumulate on and PADDLE # around magnetic housing which may affect proper operation. Please conduct appropriate fluid magnetic particle evaluation and operational SWITCH OPERATION (NO, NC, OR SPDT) tests prior to and during installation and use. POWER CORD LENGTH INSTALLATION DIMENSIONSEPOXY/URETHANE ⁄ ” ¾”POTTED HOUSING 3” 1 ⁄ ” A/FSTANDARD2’ POWER CORD 1½”–1” TEE 1” NPT 1 ⁄ ”–1½” & 3” TEESENCAPSULATED ENCAPSULATEDMAGNET REED SWITCHBENDING BLADEELIMINATES HINGESAND BEARINGS,WHICH CANMALFUNCTIONDUE TO MATERIALCONTAMINATIONAND CORROSION. 13 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
FLOW SWITCH MODEL Q-12N Q-12CR Model Q-12 is provided with three Q-12DS factory adjustable parameters which POOL & SPA VERSION provide performance flexibility to meet a multitude of applications: KEY FEATURES 0.7–590 GPM (2.6–2,233 L/m) Flow Range 32˚–200˚F (0˚–93˚C) • Paddle Area Working Temp • Paddle Length • Paddle StiffnessMax. flow may be five times normal Working Pressure 250 psi (1.724 kPa)flow. Process Connection ½\" NPT, ¾\" NPT Electrical (Reed) Switch SPNO 0.5APositive stop eliminates fatigue effectsof turbulence, vibration and flowsurge on flow detecting element.Very low pressure drop - typically less TYPICAL USESthan 1.0 psig at normal flow rate. Monitoring flow of coolant supplied to:Small size and low profile provideseasy mounting in crowded Brakes and Clutches Emergency Wash-Down Showersinstallations. Computer Systems Marine and Stationary Engines Diodes, SCRs, Triacs, etc. RF and Radar TransmittersPower the driving coil of small ice Electromagnets Spot welderscube relays as well as some 30A Fire Sprinkler Flow Alarms Transformerspower relays. Lasers Vacuum SystemsAvailable with NO, NC or SPDT Reed In Chemical Processing:Switch Fluid Blending Systems Liquid TransferSwitches 5VDC to 240VAC. Heat Transfer Fluids Monitor Filter CloggingSwitch employs magnetic coupling. Liquid Scrubbers Starting back-up pumpsSend us your special requirements. We will quote a special unit to meetthose requirements. Monitoring pump output, valve position, systems flow status In Water Treatment: Irrigation Systems Salt and Fresh Water Systems TYPICAL WORKING FLUIDS For use in a broad spectrum of industrial fluids, such as: SIDE VIEW Cooling Tower Water Water (saltwater, pure, tap, etc.) Glycol Solutions Lubricating Oils½” NPT Mild Acids Gasoline Plating Solutions JP-4 0.65” TOP VIEW 0.3” 1.2” ½” OR ¾” NPT 2D TURBULENT 5D FLOW REDUCTIONHARWIL® 541 Kinetic Drive Oxnard, CA 93030 1.1” MOUNT IN www.harwil.com 1.4” ANY POSITION 1.8” Phone: (805) 988-6800 14 Fax: (805) 988-6804 10-8-15 Email: [email protected]
MODEL SELECTION CHART Q-12N Q-12DS Q-12CR POOL & SPA VERSIONFlow Range (Water calibrated at 70˚F / 21˚C)PIPE NOMINAL ON/OFF PADDLE NUMBER TECHNICAL SPECIFICATIONSSIZE SWITCH POINT RANGENPT (GPM) ELECTRICAL (REED) SWITCH CHARACTERISTICS ON OFF 0.9 0.8 3 (.7SM)* SPNO¾” 3 2 3SM Contact Ratings: 11 10 6S AC Voltage (max. switching) 300VAC 1.1 1.0 3 (.7M)* DC Voltage (max. switching) 350VDC Current (max. switching) 0.5A1” 4 3 4S Current (max. carrying) 2.5A 65 6S Power (max) (VA, W) 50 watts Contact resistance (max. initial) 0.15 ohms 2.8 2.5 4 (.7L)* Insulation resistance 1010 ohms 13 12 4S Operating temperature -40°F–240°F (-40°C–115°C)1½” 15 6M OPTIONAL: SPNC or SPDT, 3 watt, 100VAC/VDC. 16 INDUCTIVE LOADS 21 19 6S Switch contacts have been tested with small relays and 30A J-C relay 4.9 4.4 4 (.7L)* inductive driving coils at 120/240VAC to 500,000 operations without failure. 15 12 4M2” 18 4S 23 27 22 6M Q-12N (NORYL) WORKING PRESSURE: 200 psig max. @ 70˚F 11.0 9.9 4 (.7L)* WORKING TEMPERATURE: 180˚F @ ambient pressure WETTED MATERIALS: Body: Noryl (PPO) (10% glass fibers) 33 25 4M Paddle: 316 stainless steel Seal: Epoxy3” 57 45 4S Q-12CR (FORTRON) 65 58 6M WORKING PRESSURE: 250 psig max. @ 70˚F WORKING TEMPERATURE: 200˚F @ ambient pressure 82 78 6S WETTED MATERIALS: Body: Fortron (PPS) (40% glass fibers) Paddle: Hastelloy C. Seal: Epoxy 19.6 17.6 4 (.7L)* SAMPLE PART NUMBER 56 43 4M OPTION 1: Q-12N / ¾ / SB / 4S / NO / 14” 95 83 4S BASE MODEL ↑ ↑ ↑ ↑ ↑ 120 108 6M PROCESS CONNECTION ½\" or ¾\" NPT 150 140 6S PIPE SIZE: SB ¾\" TO 1\"; LB 1½\"+ PADDLE NUMBER 30.6 27.5 4 (.7L)* SWITCH OPERATION (NO OR NC) 92 69 4M ELECTRICAL CONNECTION OPTION5” 150 130 4S Note: Tee and orifice options available when ordering. NOTE: Model Q-12N employs magnetic coupling between bending blade 180 170 6M and switch body. Magnetic particles can accumulate on and around magnetic housing which may affect proper operation. Please conduct appropriate fluid 230 220 6S magnetic particle evaluation and operational tests prior to and during installation and use. 135 95 4M* 220 180 4S6” 220 6M 260 340 310 6SCall our customer support for a wider range of pipe sizes. (805) 988-6800* = ReEqLuEirCeTs R¾ICNAPTLpCroOceNssNcoEnCneTcItOionN OPTIONS OPTION 1 OPTION 2 OPTION 3 OPTION 4 BASIC UNIT SUPPLIED WITH BASIC UNIT WITH TWO- BASIC UNIT W/ DMP TAPERED BASIC UNIT WITH ½” FLEXIBLE TWO 0.187 x 0.020 MALE CONDUCTOR INSTRUMENT RUBBER GROMMET ATTACHMENT SPIRADUCT PLASTIC CONDUIT & SPADE TERMINALS RECESSED CABLE POTTED IN PLACE. FOR WATERTIGHT SEAL & STRAIN FITTINGS. ELECTRICAL CABLE NOT IN ½” NPT NIPPLE SECTION. PVC TEE OPTIONAL. RELIEF. PVC TEE OPTIONAL. SUPPLIED. PVC TEE OPTIONAL. 15 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
FLOW SWITCH MODEL Q-15N Q-15CRModel Q-15 is the most sensitive paddle typeflow switch available. It utilizes Hall Effect KEY FEATURES 0.7–590 GPM (2.6–2,233 L/m)technology and is programmed for the highest Flow Range 32˚–180˚F (0˚–82˚C)sensitivity. Working Temp 250 psi (1.724 kPa) Working Pressure ½\" NPT, ¾\" NPTModel Q-15 comes standard with 8 conductor Process Connection SPNO .25A (250 mA)modular cable and Cat 3 modular connector. Electrical ContactsOther cable/connector combinations availableupon special order. TYPICAL USESMax. flow may be five times normal flow. Monitoring flow of coolant supplied to:Positive stop eliminates fatigue effects of turbu- Brakes and Clutches Emergency Wash-Down Showerslence, vibration and flow surge on flow detecting Computer Systems Marine and Stationary Engineselement. Diodes, SCRs, Triacs, etc. RF and Radar Transmitters Electromagnets Spot weldersVery low pressure drop - typically less than 1.0 Fire Sprinkler Flow Alarms Transformerspsig at normal flow rate. Lasers Vacuum SystemsSmall size and low profile provides easy In Chemical Processing:mounting in crowded installations. Fluid Blending Systems Liquid TransferSwitch employs magnetic coupling. Heat Transfer Fluids Monitor Filter CloggingSend us your special requirements. We will quotea special unit to meet those requirements. Liquid Scrubbers Starting back-up pumps Monitoring pump output, valve position, systems flow status In Water Treatment: Irrigation Systems Salt and Fresh Water Systems TYPICAL WORKING FLUIDS For use in a broad spectrum of industrial fluids, such as: SIDE VIEW Cooling Tower Water Water (saltwater, pure, tap, etc.) Glycol Solutions Lubricating Oils 1.4” Mild Acids Gasoline 0.3” Plating Solutions JP-4 TOP VIEW½” OR ¾” NPT 1.2” 16 2D TURBULENT 10-8-15 5D FLOW REDUCTION 1.1” 1.4” 1.8”HARWIL® 541 Kinetic Drive MOUNT IN Oxnard, CA 93030 ANY POSITION www.harwil.com Phone: (805) 988-6800 Fax: (805) 988-6804 Email: [email protected]
Q-15N Q-15CR MODEL SELECTION CHART TECHNICAL SPECIFICATIONSFlow Range (Water calibrated at 70˚F / 21˚C) ELECTRICAL CHARACTERISTICS SPNOPIPE NOMINAL ON/OFFSIZE SWITCH POINT RANGE PADDLE NUMBER Input Voltage 8 to 24 vdcNPT (GPM) Contact Rating ON OFF Switching Voltage Switching Current 0.9 0.8 3 (.7SM)* Contact Resistance 28 vdc max 1.5 amp (250 mA) max¾” 3 2 3SM .25 ohms 11 10 6S 1.1 1.0 3 (.7M)*1” 4 3 4S 65 6S 2.8 2.5 4 (.7L)* 13 12 4S1½” 15 6M 16 21 19 6S 4.9 4.4 4 (.7L)* Q-15N (NORYL) WORKING PRESSURE: 200 psig max. @ 70˚F 15 12 4M WORKING TEMPERATURE: 180˚F @ ambient pressure2” 18 4S WETTED MATERIALS: Body: Noryl (PPO) 22 6M (10% glass fibers) Paddle: 316 stainless steel Seal: Epoxy 23 27 Q-15CR (FORTRON) WORKING PRESSURE: 250 psig max. @ 70˚F 11.0 9.9 4 (.7L)* WORKING TEMPERATURE: 200˚F @ ambient pressure WETTED MATERIALS: Body: Fortron (PPS) (40% glass fibers) 33 25 4M Paddle: 316 Hastelloy C. Seal: Epoxy3” 57 45 4S SAMPLE PART NUMBER 65 58 6M OPTION 1: Q-15N / ¾ / SB / 4S / 2FT 82 78 6S BASE MODEL ↑ ↑ ↑ ↑ 19.6 17.6 4 (.7L)* PROCESS CONNECTION ½\" or ¾\" NPT 56 43 4M PIPE SIZE: SB ¾\" TO 1\"; LB 1½\"+4” 95 83 4S PADDLE NUMBER LENGTH OF CABLE (FT)) 120 108 6M 150 140 6S Note: Tee and orifice options available when ordering. NOTE: Model Q-15N employs magnetic coupling between bending blade 30.6 27.5 4 (.7L)* and switch body. Magnetic particles can accumulate on and around magnetic housing which may affect proper operation. Please conduct appropriate fluid 92 69 4M magnetic particle evaluation and operational tests prior to and during installation and use.5” 150 130 4S 180 170 6M 230 220 6S 135 95 4M* 220 180 4S6” 220 6M 260 340 310 6SCall our customer support for a wider range of pipe sizes. (805) 988-6800* = Requires ¾ NPT process connection 17 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
FLOW SWITCH MODEL Q-16THE Q-16. MAXIMUM RELIABILITY, KEY FEATURES 4–500 GPM (15–1,893 L/m)MINIMUM COST. Flow Range 32˚–250˚F (0˚–121˚C)The Q-16 is the newest addition to Harwil’s Working Temp 200 psi (1.379 kPa)heavy-duty line of flow switches. The switch Working Pressure 1\" NPTis used to signal, start, or stop electronically Process Connection SPDT 15A or Dry Circuitoperated equipment when flow or no-flow Electrical Switch NEMA 1 (Not for use in hazardous locations)conditions occur. The Q-16 benefits from 40 Enclosure UL 508 & UL 353years of flow switch development experi- Approvalsence for every conceivable application. TYPICAL USES Cooling TowersHarwil’s patented elastomeric sealing system Water Treatmentis superior to the metal bellows that are For use insubject to metal fatigue and corrosion. This Boilersseal system has been field-proven for over a Chillersdecade. IrrigationThe Q-16 can be used in pipes 1 inch and For direct replacement of mostlarger, with set points as low as 4 GPM 1\" paddle style flow switches.(15.2 LPM) to over 500 GPM (1,893 LPM)in larger pipe sizes. The Q-16 uses a 15A 15 AMP - SPDT MICROSWITCHSPDT micro switch that can control a ½ 1/2\" CONDUIT CONNECTIONhorsepower motor. ADJUSTING SCREW Multiple Quick-Change Paddles TENSION SPRING Patented EPDM Seal, Superior To Metal Bellows Field Adjustable Set Points Field Adjustable Paddles Direct Replacement For Most Paddle- Type Flow Switches Best Flow Sensitivity Among Paddle-Type Flow Switches Stainless Steel Paddles And Shaft NEMA 1 Enclosure Industry-Leading 3 Year Warranty PRODUCT DIAGRAM COVER NORMALLY CLOSED NORMALLY OPEN COMMONFEED THRU SHAFT ASSY FLOW SWITCH BODY STAINLESS STEEL PADDLES (4) WEIGHT: 1.5 lb. 0.68 kg 18 10-8-15
MODEL Q-16 MODEL SELECTION CHART HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH)Flow Range (Water calibrated at 70˚F / 21˚C) ≈ 10% at upper end of flow range ≈ 30% at lower end of flow range SWITCHPOINT RANGE (GPM) DIFFERENTIAL PRESSURE DROPS ACROSS UNIT Under normal operating conditions:PIPE SIZE NPT MIN. ADJUST. MAX. ADJUST. ON OFF ON OFF ≈ 1\"–3\" pipe, less than 1 psi ≈ 4\"–48\" pipe, negligible 1\" 4 2 8 7 WORKING LINE PRESSURE WORKING TEMPERATURE 200 psig max. 250˚F max. continuous. 1½\" 7 5 13 11 2\" 12 7 27 26 2½\" 18 12 35 32 WETTED MATERIALS Paddle: 316 stainless steel Seal: EPDM 3\" 27 19 52 49 Body: Brass Shaft: 304 Stainless Steel 4\" 63 50 123 120 ELECTRICAL SWITCH CHARACTERISTICS 5\" 125 100 238 232 SPDT ¼A @ 250VDC 15A, ½ hp @ 125 or 250VAC 10,000,000 Operations Median ½A @ 125VDC 6\" 190 158 350 338 Call our customer support for a wider range of pipe sizes. (805) 988-6800 Model Q-16 can also be fitted with a SPDT Gold Cross Bar Switch for computer/PLC interface.INSTALLATION DIMENSIONS SIDE VIEW FRONT VIEW TOP VIEW 3 3 3 3 16 4 1 19 1 1 32 4 1 1 2 3 3 16 2 1 163 3 4 PLAN VIEW 1\" NPT INCLUDED FRONT VIEW PADDLE SET SIDE VIEW GIVES LENGTHS OF: 1 1/2, 2 1/2 3 5/8, 7 1/4 19 10-8-15
LEVEL SWITCH MODEL L-5 L-5SS SPECIFIC GRAVITY COMPENSATING. Featuring continuously adjustable float buoyancy control to allow use in NON- fluids with specific gravity down to 0.6. MAGNETIC Continuous buoyancy control allows switch activation at oil/water KEY FEATURES interface. Working Fluid Specific Gravity Adjustable between 0.6 & 1.0+ May be used in hazardous areas when used with intrinsically safe relays. Working Temp 32˚–180˚F (0˚–82˚C) Consult factory for other dual-component fluid interface systems. Working Pressure 300 psi (2,068 kPa) Horizontal Mounting Only Process Connection 1\" NPT High/Low Liquid Level Alarm Solenoid Valve On/Off Control Electrical Switch SPDT 15A or Dry Circuit TYPICAL USESL-5 For use in particle contaminated fluids, such as: Seawater Contaminated Ground Water Sewage Rusty Coolant Water Waste Water TYPICAL WORKING FLUIDS L-5SS Alcohols Machine Cutting Oils Glycols SlurriesPRODUCT DIAGRAM Soap Solutions Water (L-5) 304 STAINLESS STEEL FLOAT 316 STAINLESS STEEL SHAFT (L-5) RED BRASS BODY (L-5SS) 2x 304 STAINLESS STEEL (L-5SS) 316 STAINLESS STEEL FLOAT WITH EVERLUBE 6108 PTFE COATING 1” x 2” RED BRASS BUSHING 1” NPT Phone: (805) 988-6800 ALLOWS FLOAT TO PASS Fax: (805) 988-6804 FLOAT BUOYANCY ADJUSTMENT THROUGH WALL OF TANK Email: [email protected] WEIGHT: 3 lb.HARWIL® 541 Kinetic Drive 1.36 kg Oxnard, CA 93030 20 www.harwil.com 10-8-15
MODEL L-5 L-5SS DOUBLE POLE, DOUBLE THROW (DPDT) TECHNICAL SPECIFICATIONS MODEL LD-5 ALSO AVAILABLE HYSTERESIS (∆ LIQUID LEVEL TO ACTIVATE/DEACTIVATE SWITCH)2 single pole, double throw (SPDT) switches provide DPDT action. 2 physically ≈ ¼\" travelganged but electronically independent switches provide a combination of 2isolated AC or DC circuits; high or low voltage circuits; or power or gold cross WORKING FLUID SPECIFIC GRAVITY RANGEbar computer/PLC dry circuits. Adjustable between 0.6 and 1.0+Electrical connection is made directly to switch terminals with standard spade WORKING PRESSURE WORKING TEMPERATURE“Quick Connects” supplied with each unit. 300 psi max. continuous 180˚F max. continuous. WETTED MATERIALS (RED BRASS) Body and Bushing: Red brass Float: 304 stainless steel Float Shaft: Phosphor bronze Seal: EPDM Hardware: 316 stainless steel Gasket: Cork/Nitrile blend ELECTRICAL CONNECTION WETTED MATERIALS (STAINLESS STEEL)GROMMET CABLE O.D. DIAGRAM Body, Bushing, Float Shaft, Float Coating: Everlube 6108 PTFE A 0.25” Hardware: 316 stainless steel Seal: Viton AA 0.30” O.D. Float: 304 stainless steel Gasket: Teflon B 0.37” C 0.50” ELECTRICAL SWITCH CHARACTERISTICS CONDUIT FITTINGS SPDT 5A @ 125VAC (Tungsten lamp 15 A, ½ hp @ 125 or 250VAC load) ½A @ 125VDC, ¼A @ 250VDC 10,000,000 operations median Gold Cross Bar Dry Circuit Computer/PLC Interface SPDT Switch Model also available.F 0.5” straight F90˚ 0.5” 90˚ SAMPLE PART NUMBERS OPTION 1: L-5 / A OPTION 2: L-5 / F BASE MODEL ↑ BASE MODEL ↑ GROMMET SIZE ½\" FLEXIBLE CONDUIT FITTINGINSTALLATION DIMENSIONSHOLE TO SUIT STRAIN RELIEF CABLE FITTING SUPPLIED 1” x 2” BRASS BUSHINGBY HARWIL OR ANY STANDARD ½” RIGID OR FLEXIBLE 1” NPTELECTRICAL CONDUIT FITTING 3⁄” ≈¼” LIQUID LEVEL DIFFERENTIAL 1⁄ ” SWITCH ACTUATION 2” DIA. 1⁄” CENTERED AROUND 4⁄ ” CENTER LINE ⁄ ” FINGER TIGHTOPTION 1, 2 9⁄ ” 6” 2⁄ ” 2⁄ ” L-5SS: LENGTH WITH 2ND FLOAT 21 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
LEVEL SWITCH MODEL L-8N L-8CRSPECIFIC GRAVITY COMPENSATING.Featuring continuously adjustable float buoyancy control to allow use in NON-fluids with specific gravity down to 0.6. MAGNETICContinuous buoyancy control allows switch activation at oil/waterinterface. KEY FEATURESMay be used in hazardous areas when used with intrinsically saferelays. Working Fluid Specific Gravity Adjustable between 0.6 & 1.5+Consult factory for other dual-component fluid interface systems.Horizontal Mounting Only Working Temp 32˚–200˚F (0˚–93˚C)Water/Oil Interface switch pointFoam/Fluid interface switch point Working Pressure 75 psi (517 kPa)High/Low Liquid Level AlarmLiquid level indication Process Connection 1\" NPTDirect pump controlSolenoid Valve On/Off Control Electrical Switch SPDT 15A or Dry CircuitAvailable with Optional Filter Boot For Use in Highly Particle Contami-nated Liquids. TYPICAL USESSuper-simple maintenance and checkout for personnel using a standardtest meter. For use in particle contaminated fluids, such as: Seawater Contaminated Ground Water Sewage Rusty Coolant Water Soap Solutions Soap Solutions TYPICAL WORKING FLUIDS Water Mild Acids Some Hydrocarbons Mild Bases Chemical Solutions Inorganics Glycols Oils Pure WaterPRODUCT DIAGRAM SPDT 15A SWITCH MODEL OR DRY CIRCUIT COMPUTER/PLC INTERFACE MODEL ELECTRICAL CABLE STRAIN RELIEF OR ½” FLEXIBLE CONDUIT 1¼”–1” NORYL BUSHING or 1½”–1” NORYL CONNECTOR (L-8CR: 1¼”–1” FORTRON BUSHING or 1½”–1” FORTRON) 1” NPT L-8: 316 STAINLESS STEEL FLOAT SHAFT L-8CR: HASTELLOY FLOAT SHAFT CONTINUOUS BUOYANCY NEMA 6 COVER CORROSION RESISTANT FIBERGLASS NORYL OR FORTRON ADJUSTMENT REINFORCED NORYL BODY AND ENGINEERING PLASTIC COVER (L-8CR USES FORTRON) FLOATHARWIL® 541 Kinetic Drive Oxnard, CA 93030 WEIGHT: 0.5 lb. Phone: (805) 988-6800 www.harwil.com 0.23 kg Fax: (805) 988-6804 22 Email: [email protected] 10-8-15
ELECTRICAL CONNECTION L-8N L-8CRGROMMET CABLE O.D. DIAGRAM MODEL A 0.25” AA 0.30” O.D. B 0.37” C 0.50” TECHNICAL SPECIFICATIONS CONDUIT FITTINGS (AVAILABLE AT EXTRA COST) HYSTERESIS (∆ LIQUID LEVEL TO ACTIVATE/DEACTIVATE SWITCH) ≈ ¼\" max. travelF 0.5” straight F90˚ 0.5” WORKING FLUID SPECIFIC GRAVITY RANGE 90˚ Adjustable between 0.6 and 1.5+ WORKING PRESSURE: 75 psi max. continuous & 100 psi max. non-operating ELECTRICAL SWITCH CHARACTERISTICSSAMPLE PART NUMBERS SPDT 5A @ 125VAC (Tungsten lamp OPTION 1: L-8N / A 15 A, ½ hp @ 125 or 250VAC load) BASE MODEL ↑ ½A @ 125VDC, ¼A @ 250VDC 10,000,000 operations median GROMMET SIZE OPTION 2: L-8N / F Gold Cross Bar Dry Circuit Computer/PLC Interface SPDT Switch Model BASE MODEL ↑ also available. 0.1A or less, 5–24 VAC/DC. ½\" FLEXIBLE CONDUIT FITTING L-8N (NORYL) WORKING TEMPERATURE: 180˚F max. continuous.FILTER BOOT WETTED MATERIALS: Body, Float and Bushing: Noryl (PPO) (10% glass fibers) Float Shaft and Screws: 316 stainless (Hypalon available by special order) Diaphragm: EPDM Optional Filter Boot: EPDM (Viton available by special order) PERMEABLE GASKET L-8VCR (FORTRON) WORKING TEMPERATURE: 200˚F max. continuous. WETTED MATERIALS: Body, Float and Bushing: Fortron (PPO) (40% glass fibers) Pivot Pin: Hastelloy C FILTER BOOT CHAMBER FILLED WITH WORKING FLUIDINSTALLATION DIMENSIONS OF TANK TO EQUALIZE PRESSURE DIFFERENTIAL PERMEABLE SHRINK TUBE SEAL WIDTH 1¾” 1½” A/F HEX2⁄ ” LIQUID LEVEL DIFFERENTIAL ≈¼” 1.35” DIA. ¼” ⁄” 4⁄” 3¼” 3⁄ ” 9⁄ ” 23 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
LEVEL SWITCH L-21+ MODEL L-21NThe L-21 is a low cost, high performance level switch made fromhighly durable plastics. It features a variable liquid level dif- L-21VCRferential and a single point pump up/pump down level control.Interchangeable differential band modules, for all non-L-21+ KEY FEATURESversions, allow for 5 minute on-site switching of differentials Working Fluid Specific Gravity 0.7 minimumfrom 1.0” to 2.0” to 3.0” to 5.0” in any sequence to satisfyvariable operational requirements as they occur. Its large Working Temp 32˚–200˚F (0˚–93˚C)differential provides immunity to nuisance switch tripping due tosevere wave action and turbulence. The large differential also Working Pressure 250 psig (1.724 MPa)provides very low cost single point pump up/pump down level Process Connection 1¼\" NPTcontrol.Maintenance and checkout is a snap for plant maintenance Electrical Switch SPDT 15Apersonnel using any standard multimeter. Each unit comeswith detailed instruction manual and parts list. Introducing the L-21+TYPICAL USES www.HPlastic test strips are available for testing in Water Level Control In: (805) 9your particular real world chemical sales@henvironment. Pump-uCopoli/ngPTouwmersp-down PLlaetivngeTlanCksontroller We’ve taken an alreadyWuanshiiqnugeTaannksd effective deFissihgFnaramnsd further improved upon it, now giving yoFuouunptations15 feet of level cAoqnutraorilumwsith a single switch. A C E B D TYPICAL WORKING FLUIDS Clean Water Contaminated Ground Water 1.35” Filtered Sewage Filtered Waste Water Mild Acids Inorganic Aqueous Solutions Mild Bases Sea Water 1” 2”LIQUID LEVEL DIFFERENTIAL DIMENSONS 3” 4” 3.25” AB C D E Level Differential Outside Inside Depth Below Depth Above 4’ Mount Switch Switch Inches Mount 7.5 0.7 0.3 Wall Mount 1 4.5 8.2 1.4 0.6 3’ Tank Option 2 5.2 8.9 2.1 0.9 3 5.9 10.3 3.5 1.5 5 7.3 15.2 8.4 3.6 2’ Tank 12 12.2 19.4 12.6 5.4 18 16.4 23.6 16.8 7.2 1’ Tank 24 20.6 27.8 21 9Submersible 30 24.8 32.0 25.2 10.8 2’Tree Mount 36 29.0 40.4 33.6 14.4 48 37.4 48.9 42 18 1’ Diff Option 60 45.9 Differential (Diff) r *Not to scaleHARWIL® 541 Kinetic Drive WEIGHT: 5 oz. Phone: (805) 988-6800 Oxnard, CA 93030 142 g Fax: (805) 988-6804 www.harwil.com 24 Email: [email protected] 10-8-15
L-21+ MODEL L-21N L-21VCR ELECTRICAL CONNECTION TECHNICAL SPECIFICATIONS GROMMET CABLE O.D. DIAGRAM HYSTERESIS (∆ LIQUID LEVEL TO ACTIVATE/DEACTIVATE SWITCH) A 0.25” ≈ 5\" max. travel (N/VCR). ≈ 15' max. travel (+). AA 0.30” O.D. B 0.37” C 0.50” ELECTRICAL SWITCH CHARACTERISTICS SPDT 4A @ 125VAC (Tungsten lamp 15 A, ¼ hp @ 125 or 250VAC load) ½A @ 125VDC, ¼A @ 250VDC CONDUIT FITTINGS (AVAILABLE AT EXTRA COST) F 0.5” straight F90˚ 0.5” Note: Model L-21 employs magnetic coupling between float arm and 90˚ switch body. Magnetic particles can accumulate on and around magnet housing which may affect proper operation. Please conduct appropri- ate fluid magnetic particle evaluation and operational tests prior to and during installation and use. SAMPLE PART NUMBERS WORKING FLUID SPECIFIC GRAVITY 0.7 minimum OPTION 1: L-21N / 15A /1 /A L-21+ & L-21N (NORYL) BASE MODEL ↑ ↑ ↑ WORKING PRESSURE: 250 psi max. continuous WORKING TEMPERATURE: 180˚F max. continuous. SWITCH CAPACITY WETTED MATERIALS: Body, Float and Bushing: Noryl (PPO) LIQUID LEVEL DIFFERENTIAL (10% glass fibers) Pivot Pin: 316 stainless steel GROMMET SIZE OPTION 2: L-21N / 15A / 5 /F L-21VCR (FORTRON) WORKING PRESSURE: 250 psi max. continuous BASE MODEL ↑ ↑ ↑ WORKING TEMPERATURE: 200˚F max. continuous. SWITCH CAPACITY WETTED MATERIALS: Body, Float and Bushing: Fortron LIQUID LEVEL DIFFERENTIAL (PPO) (40% glass fibers) Pivot Pin: Hastelloy C ½\" FLEXIBLE CONDUIT FITTING INSTALLATION DIMENSIONSA NEMA 6 NORYL C NORYL ENGINEERING E COVER AND BODY B PLASTIC FLOAT D (L-21VCR: FORTRON L-21VCR: FORTRON FLOAT COVER AND BODY) 1¼” NPT L-21+: DELRIN™ (POM) L-21N: 316 STAINLESS SHAFT L-21VCR: HASTELLOY C SHAFT 1.35” 3” 1” 2” 3.25” 4” 25 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
LEVEL SWITCH MODEL L-30N L-30CRParticle contamination resistance is provided by a single convoluteelastomeric flexible seal which is continuously flushed by the working NON-fluid. MAGNETICModels for vertical or horizontal mounting.Super-simple maintenance and checkout for personnel using a standard KEY FEATUREStest meter.Optional Nitrophyl (Nitrile) Closed Cell Float for mounting switch in 1” Working Fluid Specific Gravity 0.8 minimumNPT fitting.Intrinsically Safe Relay allows Model L-30 to be used in hazardous Working Temp 32˚–200˚F (0˚–93˚C)areas.High/Low Liquid level alarm Working Pressure 75 psi (517 kPa)Liquid level indicationPump Up/ Pump Down Control Process Connection 1\" NPTSolenoid Valve controlAvailable with Optional Filter Boot Electrical Switch SPDT 15A or Dry CircuitBoth horizontal and vertical models are available withDMP cable connector or “F” model ½” conduit fitting. TYPICAL USES For use in particle contaminated fluids, such as: Medium Slurries Contaminated Ground Water Sewage Machine Cutting Oils Waste Water TYPICAL WORKING FLUIDSL-30N Water Mild Acids Seawater Mild Bases Rusty Coolant Water Various Chemicals L-30NVPRODUCT DIAGRAM HORIZONTAL MODELS BUSHING MOUNT PIPE NIPPLE MOUNT1¼”–1” NORYL BUSHING or 1½”–1” NORYL DMP WATER/OIL RESISTANT STRAIN RELIEF ELECTRICAL(L-30CR: USES FORTRON) CABLE CONNECTOR NORYL FLOAT ½” PIPE NIPPLE (L-30CR: FORTRON FLOAT) BUSHING TEFLON TAPE “F” COVER SEAL ≈¼” LIQUID LEVEL DIFFERENTIAL≈ ⁄ ” SWITCH POINT316 STAINLESS STEEL SHAFT 1” NPT (L-30CR: HASTELLOY C SHAFT) SPDT 15A SWITCH MODEL NEMA 6 ENCLOSURE OR DRY CIRCUIT COMPUTER/ PLC INTERFACE MODELHARWIL® 541 Kinetic Drive WEIGHT: 0.5 lb. Phone: (805) 988-6800 Oxnard, CA 93030 0.23 kg Fax: (805) 988-6804 www.harwil.com 26 Email: [email protected] 10-8-15
ELECTRICAL CONNECTION L-30N L-30CRGROMMET CABLE O.D. DIAGRAM MODEL A 0.25” AA 0.30” O.D. B 0.37” C 0.50” TECHNICAL SPECIFICATIONS CONDUIT FITTINGS (AVAILABLE AT EXTRA COST) HYSTERESIS (∆ LIQUID LEVEL TO ACTIVATE/DEACTIVATE SWITCH) ≈ ¼\" max. travel ELECTRICAL SWITCH CHARACTERISTICSF 0.5” straight F90˚ 0.5” SPDT 5A @ 125VAC (Tungsten lamp 90˚ 15 A, ½ hp @ 125 or 250VAC load) ½A @ 125VDC, ¼A @ 250VDC 10,000,000 operations median Gold Cross Bar Dry Circuit Computer/PLC Interface SPDT Switch Model also available. 0.1A or less, 5–24 VAC/DC.SAMPLE PART NUMBERS OPTION 2: L-30N / F WORKING FLUID SPECIFIC GRAVITY: OPTION 1: L-30N / A BASE MODEL ↑ 0.8 minimum BASE MODEL ↑ GROMMET SIZE ½\" FLEXIBLE CONDUIT FITTING WORKING PRESSURE: 75 psi max. operatingFILTER BOOT 100 psi max. non-operating L-30N (NORYL) WORKING TEMPERATURE: 180˚F max. continuous. WETTED MATERIALS: Body, Float and Bushing: Noryl (PPO) (10% glass fibers) Float Shaft and Screws: 316 stainless steel Diaphragm: EPDM (Hypalon optional) Optional Filter Boot: EPDM (Viton available by special order) Optional Float Material: Polypropylene PERMEABLE GASKET L-30CR (FORTRON) WORKING TEMPERATURE: 200˚F max. continuous. WETTED MATERIALS: Body, Float and Bushing: Fortron (PPS) (40% glass fibers) Float Shaft: Hastelloy C (Titanium/Tantalum by special order) Diaphragm: Viton Optional Filter Boot: Viton Optional Float Material: Polypropylene CHAMBER FILLED WITH WORKING FLUID OF TANK TO EQUALIZE PRESSURE DIFFERENTIAL FILTER BOOT PERMEABLE SHRINKINSTALLATION DIMENSIONS TUBE SEAL 1.5” A/F HEX CUSTOMER SUPPLIED “F” COVER WIDTH 1.75” STANDARD PVC FITTED WITH 0.5” PIPE NIPPLE FEMALE1.35 ½” NPT “F” COVER MOUNTING HOLE 2⁄ ” 3¾” ≈8½” 3.25” ⁄” 0.25” ≈5” SWITCH POINT 4 ⁄” 9 ⁄” 3⁄ ” ≈0.25” LIQUID LEVEL DIFFERENTIAL 27 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
LEVEL SWITCH MODEL L-40N L-40VCRSide and Top MountCorrosion-resistant plastic with optional metal pivot pin (available in KEY FEATURES316 stainless steel, Hastelloy C, Titanium, Tantalum, or Teflon).10 times less sensitive from deposit and build-up of contaminants than Working Fluid Specific Gravity Top Mount: 0.8 | Side Mount: 0.7sliding float models.Each unit can be supplied with a special made to order 1¼” x ¼” x ½” Working Temp 32˚–200˚F (0˚–93˚C)reducer bushing for through wall mounting.Output wire can be twisted pair 22 gauge or two conductor PVC Working Pressure 250 psi (1.724 MPa)heavy wall instrument cable.STANDARD: SPST reed switch for 120/240VAC 50 Watt power or DC Process Connection ¼\" NPTdry circuit for computer/PLC interface. Electrical Switch SPNO or SPNC, 0.5A TYPICAL USES For use in particle contaminated fluids, such as: TYPICAL WORKING FLUIDS LARGE SURFACE AREA LOOSE PIVOT AND Mild Acids Seawater ENCOURAGES LONG MOMENT ARM Mild Bases Filtered Sewage CONTAMINATION INHIBIT DEPOSITS Pure Water Contaminated Ground Water DEPOSIT AND BUILDUP AND UPGRADE Process Water PERFORMANCE 10:1 OVER “DONUT” DESIGNPRODUCT DIAGRAM NORYL BUSHING EXISTING PLUG EXISTING MOUNT FLANGE NORYL SWITCH HOUSING (L-40VCR: FORTRON BUSHING) MOUNT PVC NIPPLE OF (L-40VCR: FORTRON HOUSING) LEADS 24” LONG ANY DESIRED PVC OR MORE LENGTH COUPLING CERAMIC MAGNETNORYL FLOAT REED SWITCH 316 STAINLESS STEEL(L-40VCR: FORTRON FLOAT) PIVOT PIN (L-40VCR: HASTELLOY C SHAFT)HARWIL® 541 Kinetic Drive WEIGHT: 5 oz. Phone: (805) 988-6800 Oxnard, CA 93030 142 g Fax: (805) 988-6804 www.harwil.com 28 Email: [email protected] 10-8-15
SPECIFIC GRAVITY COMPENSATING MODEL L-40N MODEL L-40N/SG ALSO AVAILABLE L-40VCRCustomer specified specific gravity sensitivity. TECHNICAL SPECIFICATIONSUnique design enhances specific gravity sensitivity.Applications include fuel/water detection, oil/water detection, or detection of ELECTRICAL (REED) SWITCH CHARACTERISTICSground water contamination. SPNO SAMPLE PART NUMBER OPTION 1: L-40N / NO / HOR / 316 Contact Ratings: BASE MODEL ↑ ↑ ↑ SWITCH OPERATION AC Voltage (max. switching) 300VAC MOUNTING POSITION PIVOT PIN MATERIAL DC Voltage (max. switching) 350VDCINDUCTIVE LOADS Current (max. switching) 0.5ASwitch contacts have been tested with small relays and 30A J-C relay induc-tive driving coils at 120/240VAC to 500,000 operations without failure. Current (max. carrying) 2.5ASteady state driving coil Volt/Amp rating should be 8VA or less. Power (max) (VA, W) 50 wattsDRY CIRCUIT OPERATIONSwitch can interface with microprocessor based controllers and related Contact resistance (max. initial) 0.15 ohmscomputer circuits.NOTE: Model L-40 employs magnetic coupling between float arm and Insulation resistance 1010 ohmsswitch body. Magnetic particles can accumulate on and around magnetichousing which may affect proper operation. Please conduct appropriate Operating temperature -40°F–240°F (-40°C–115°C)fluid magnetic particle evaluation and operational tests prior to and duringinstallation and use. OPTIONAL: SPNC or SPDT, 3 watt, 100VAC/VDC. HYSTERESIS (∆ LIQUID LEVEL TO ACTIVATE/DEACTIVATE SWITCH) ≈ 3/8\" (0.375\") max. travel L-40N (NORYL) WORKING FLUID SPECIFIC GRAVITY: Top Mount: 0.8 Side Mount: 0.7 WORKING PRESSURE: 200 psi max. continuous WORKING TEMPERATURE: 180˚F max. continuous. WETTED MATERIALS: Body, Float and Bushing: Noryl (PPO) (10% glass fibers) Pivot Pin: 316 stainless steel L-40VCR (FORTRON) WORKING FLUID SPECIFIC GRAVITY: Top Mount: 0.9 Side Mount: 0.7 WORKING PRESSURE: 200 psi max. continuous WORKING TEMPERATURE: 200˚F max. continuous. WETTED MATERIALS: Body, Float and Bushing: Fortron (PPO) (40% glass fibers) Pivot Pin: Hastelloy CINSTALLATION DIMENSIONS ⁄ ” FINGERTIGHT ⁄”2 ⁄ ” MAX 0.5” 1⁄” ⁄”1.35” 1 ⁄ ” ACROSS FLATS ⁄” ⁄” ⁄” ½” NPT 1⁄ ” ⁄” 1¼” NPT or 1” NORYL OR FORTRON 3⁄” BUSHING 5⁄ ” 0.25” NPT 29 • Installation drawing and a numbered parts list is supplied with each unit. 10-8-15 • Special one-day delivery is available.
CONTROLLER MODEL CF-112The CF-112 is a stand alone interface module that automatically KEY FEATURES 32˚–180˚F (0˚–82˚C)actuates a chemical feed pump when primary bulk fluid begins to flow. Working Temp 250 psi (1.724 MPa) Working Pressure ¾\" NPT (½\" Option Available)This module can be used in isolated stand alone systems or part of Process Connection SPNOlarge complex systems. Electrical Switch 120V & 240V or 24V(AC) & 12V(DC) VoltagesModel CF-112 is available for 120VAC or 240VAC, 50-60 Hz poweras standard.Other AC and DCpower combina-tions available perrequest. TYPICAL USES For metering and/or adding chemicals in both continuous and batch fluid systems such as: Well Water Cooling Tower pH/orp Control Drinking Water Metal Plating Make Up Solutions Waste Fluid Processing Boiler Treatment Additives ALSO SEE: CF-112: Light Duty CF-12: Medium Duty CF-8: Heavy DutyPRODUCT DIAGRAM120 VAC GREEN: FLOW OUTPUT POWER FLOW INTERFACEINPUT POWER AMBER: POWER INPUT POWER MODULE CF-112 120 VAC POWER PRIMARY BULK TO FEED PUMP FLUID FLOWFLOW TO CHEMICALMIXING LSOTACTAIOTINON PRIMARY FLOW FLOW CHEMICAL PRIMARY FEED PUMP PUMP BULK MMIXIIXNINGGTANK PRIMARY CHEMICAL OTRADNIKRECTLY BULK ADDITIVE INTO PRIMARY FLUID FLOW PIPE 30 10-8-15
MODEL SELECTION CHART MODEL CF-112Flow Range (Water calibrated at 70˚F / 21˚C)PRIMARY FLOW PRIMARY FLOW ON/OFF CF-112N PART LINE SIZE SET POINT (GPM) NUMBER ON OFF¾\" 0.9 0.8 CF-112N-.751\" 1.1 1.0 CF-112N-1 WORKING PRESSURE WORKING TEMPERATURE 250 psi max. continuous 180˚F max. continuous.1½\" 2.8 2.5 CF-112N-1.5 SHOCK LIMIT SHOCK OPERATION 10g2\" 4.9 4.4 CF-112N-2 10g for 11ms with no contact open. Blade: 316 stainless steel3\" 11.0 9.9 CF-112N-3 Seal: Epoxy WETTED MATERIALS4\" 19.6 17.6 CF-112N-4 Body and Bushing: Noryl (PP0) (10% glass fibers)5” 30.6 27.5 CF-112N-5Note: Consult factory for larger pipes and lower ON/OFF switch set points.SAMPLE PART NUMBER OPTION 1: CF-112N /PIPE /VOLT ELECTRICAL SWITCH CHARACTERISTICS BASE MODEL AND PART NUMBER 1 120 Feed pump motor maximum contact ratings. VOLTAGE: 120VAC, 220VAC, 24VAC, 12VDC PIPE SIZE LMOOATDOTRY: PE (R ESIAS TIVE): 10A 6 FT 1/3 hp VOLTAGE SWITCH CONTACTS: SPNOOUTPUT 0.25” INPUTINSTALLATION DIMENSIONS Consult factory for other AC motor voltages plus DC motor operation.OUT NOTE: All circuitry potte1d.0i”n flexible urethane for max. Long term shock,IN thermal, stress, anBOdTHmINoPiUsTtuANreD OpUrToPUteT ction. CUT AND STRIPPED GREEN AMBER 1.5” BA 6 FT 240 VAC (FLOW (INPUT 2.125” 6 FT 24 VAC 3 WIRE FEMALE OOUUTTPPUUTT 12 VDC ON) POWER) CONNECTOR ININPPUUTT 0.25” 1.2” 1.0” 4 FT BOTH INPUT AND OUTPUT CUT AND STRIPPED CB 6 FT6 FT 120 VAC OUTOPUUTTPUT 1.9” 0.5” 3 WIRE FEMALE INPUINT PUT 2.2” or CONNECTOR 4 FT or 0.75” 2.6” NPT 2.0625” CD 6 FT 4 FT OUT 2.0625” 2.25” OUTPUT IN INPUT 6 FT D 4 FT OUTPUT INPUT 6 FT 31 10-8-15
CHEMICAL FEED MODEL CF-12/1GCONTROLLER CF-12/2GThe CF-12 is a stand alone interface module that automatically actuates KEY FEATURES 32˚–180˚F (0˚–82˚C)a chemical feed pump when primary bulk fluid begins to flow. Working Temp 250 psi (1.724 MPa)This module can be used in isolated stand alone systems or part of Working Pressure ¾\" NPT (½\" Option Available)large complex systems. Process Connection SPNOModel CF-v12 is available for 120VAC, 50-60 Hz power as standard. Electrical Switch 120V 50/60 HzAvailable with 1 or 2 sets of receptacles. Voltages 12' 16/3 AWG CORD LENGTH TYPICAL USES For metering and/or adding chemicals in both continuous and batch fluid systems such as: Well Water Cooling Tower pH/orp Control Drinking Water Metal Plating Make Up Solutions Waste Fluid Processing Boiler Treatment Additives ALSO SEE: CF-112: Light Duty CF-12: Medium Duty CF-8: Heavy DutyPRODUCT DIAGRAM INPUT POWER 2 GANG INPUT POWER SWITCHED OUTLETS ALWAYS ON 1 GANG SWITCHED OUTLET ALWAYS ON PRIMARY FLOW DIRECTION PRIMARY FLUID FLOW CAN BE REVERSED FLUID FLOWHARWIL® 541 Kinetic Drive 32 Phone: (805) 988-6800 Oxnard, CA 93030 Fax: (805) 988-6804 www.harwil.com 10-8-15 Email: [email protected]
MODEL SELECTION CHART MODEL CF-12/1G CF-12/2GPRIMARY FLOW PRIMARY FLOW ON/OFF CF-12N PART LINE SIZE SET POINT (GPM) NUMBER ON OFF WORKING PRESSURE WORKING TEMPERATURE 250 psi max. continuous 180˚F max. continuous. SHOCK OPERATION SHOCK LIMIT WETTED MATERIALS Blade: 316 stainless steel Seal: Epoxy Body and Bushing: Noryl (PP0)SAMPLE PART NUMBER (10% glass fibers) PVC Tee OPTION 1: CF-12N /PIPE /VOLT ELECTRICAL SWITCH CHARACTERISTICS BASE MODEL AND PART NUMBER 1 120 Feed pump motor maximum contact ratings. PIPE SIZE VOLTAGE: 120VAC VOLTAGE LOAD TYPE (RESISTIVE): 13A MOTOR: 1/2 hp SWITCH CONTACTS: SPNOINSTALLATION DIMENSIONS 5.5\" WIDTH 3.5\" WIDTH 5\" DEPTH 1 OR 2 GANG2 GANG 1 GANG 8\" WITH SIDEFRONT FRONT COVER OPEN 6.5\" HEIGHT CLEAR 8\" WITH WATER COVER RESISTANT OPEN COVER 6.5\" HEIGHT 6.5\" HEIGHT 8\" WITH COVER 8\" WITH OPEN COVER OPEN 1 1/2\" A/F HEX1/4 3/4\" OR 1/2\" NPT 1 1/2\" A/F HEX 3/4\" OR 1/2\" NPT 1\" PIPE TEE ALT.: 3/4\", 1 1/2\", 2\" 1\" PIPE TEE ALT.: 3/4\", 1 1/2\", 2\" 3.5\" 3.5\" 33 10-8-15
CHEMICAL FEED MODEL CF-8/1GCONTROLLER CF-8/2GThe CF-8 is a stand alone interface module that automatically actuates KEY FEATURES NON-a chemical feed pump when primary bulk fluid begins to flow. Flow Range MAGNETICThis module can be used in isolated stand alone systems or part of Working Templarge complex systems. Working Pressure 5 - 80 GPM (18–302 L/m)Model CF-8 is available for 120VAC, 50-60 Hz power as standard. Process Connection 32˚–180˚F (0˚–82˚C)Available with 1 or 2 sets of receptacles. Electrical Switch 100 psig @ 180˚F (466˚F kPa) 1\" NPT 12' 16/3 AWG SPDT, 1/2hp 13A or Dry Circuit CORD LENGTH TYPICAL USES Industrial Refrigeration Systems ALSO SEE: Pools and Spas Monitoring fluid flow in: Scrubbers CF-112: Light Duty Water Treatment Systems CF-12: Medium Duty Air Conditioning Systems CF-8: Heavy Duty Cooling in Data Centers Chillers Fluid Blending Systems Natural Gas TYPICAL WORKING FLUIDS Filtered Sewage Water Contaminated Ground Water Mild Acids Sulfolane Rusty Coolant Water Sea Water Waste Water Pool Water (low ppm Chlorine)INSTALLATION DIMENSIONS 5.5\" WIDTH 3.5\" WIDTH 5\" DEPTH2 GANG 1 GANG 8\" WITH 1 OR 2FRONT FRONT COVER GANG OPEN SIDE 6\" HEIGHT 6\" HEIGHT 10\" HEIGHT 8\" WITH 8\" WITH 12\" WITH COVER COVER COVER OPEN OPEN OPEN1/4 15/16 3.5\" HEIGHT 1/4 15/16 3.5\" HEIGHT 1/4 15/16 1\" NPT 1 1/2\" A/F HEX 1\" NPT 1 1/2\" A/F HEX 1\" NPT 3 1/32 MAX 3 1/32 MAX 3 1/32 MAX 2 1/32 (1 1/2\" PIPE) 2 1/32 (1 1/2\" PIPE) 2 1/32 (1 1/2\" PIPE)HARWIL® 541 Kinetic Drive 34 Phone: (805) 988-6800 Oxnard, CA 93030 Fax: (805) 988-6804 www.harwil.com 10-8-15 Email: [email protected]
MODEL SELECTION CHART MODEL CF-8/1G CF-8/2GFlow Range (Water calibrated at 70˚F / 21˚C) Accuracy ±10%PIPE SIZE NOMINAL ON/OFF SHAFT PADDLE TECHNICAL SPECIFICATIONS NPT SWITCH POINT RANGE LENGTH NUMBER HYSTERESIS (∆ FLOW RATE TO ACTIVATE/DEACTIVATE SWITCH) (GPM) 10512 ≈ 10% at upper end of flow range 2 ≈ 30% at lower end of flow range 5.0 - 3.0 - 1 DIFFERENTIAL PRESSURE DROPS ACROSS UNIT1\" 9.6 - 7.5 1 10502 Under normal operating conditions: 15.4 - 18.0 1 ≈ 1\"–3\" pipe, less than 0.5 psi ≈ 4\"–10\" pipe, negligible 12.0 - 9.5 - WORKING LINE PRESSURE: 14.2 - 11.8 23 100 psi max. non-operating Pressure over 50 psi can affect the switch point range.1 ½” 19.0 - 13.5 - 10570A 22.5 - 19.0 22 34.4 - 30.4 21 14.4 - 10.2 - 10593 16.5 - 11.0 - 10566 ELECTRICAL SWITCH CHARACTERISTICS2\" 25.8 - 21.8 23 SPDT 10,000,000 Operations Median 13A, ½ hp @ 125 or 250VAC 39.8 - 33.6 22 ½A @ 125VDC 58.0 - 50.8 21 (tungsten lamp load) 42.4 - 37.0 33 SAMPLE PART NUMBER3\" 55.6 - 49.8 32 80.6 - 65.2 31 OPTION 1: CF-8 /1 /1Call our customer support for a wider range of pipe sizes. (805) 988-6800 BASE MODEL ↑ ↑ SHAFT LENGTH PADDLE SIZEPRODUCT DIAGRAM 1 GANG INPUT POWER 2 GANG INPUT POWER SWITCHED OUTLETS ALWAYS ON SWITCHED OUTLET ALWAYS ON 2D TURBULENT5D FLOW REDUCTION MOUNT IN 35 • Installation drawing and a numbered parts list is ANY POSITION supplied with each unit. 10-8-15 • Special one-day delivery is available.
CONTROLLER MODEL LC-1The combination of any two Harwil liquid level switches and an NEMA 4 weather resistant box with two standard ½” seal tightelectronic control module mounted in a weather-resistant box flexible conduit fittings.provide a ready-to-go system for the automatic filling or emptyingof tanks or vessels. A secondary 10A SPDT relay output is also provided.System is composed of: Color coded w/ ring and labeled terminal strip.Electronic Latching/Unlatching Control Module 120 or 240VAC 50/60 Hz models available.Special electronic module design eliminates false starts due to 30A DPST motor contactor output for driving 1½ (120VAC)/3 hpturbulent wave action. (240VAC) pumps. Choose from any two Harwil liquid level switch models. Models for clean or contaminated fluids such as water, sea water, sewage, thin slurries, contaminated ground water, etc. Models for strong acids, bases, hydrocarbons, alcohols, inorganic compounds, ketones, esters or ethers. Each system is provided with a complete, descriptive parts list and an installation and wiring diagram for both level switches and control module. Maintenance and check out requires only a standard multimeter. LC-1 Control Module is delivered pre-wired and is ready to hook-up to control your liquid level. Upper and lower level switches comprising any two of the follow- ing Harwil models: L-5 L-21 LD-5 L-30 L-8 L-40 POWER POWER INPUT INPUT INPUT PUMP LC-1 LC-1 DOWN CONTROL CONTROL PUMP MODULE MODULE UPDRAIN PUMP INPUT PUMP OUTPUT 36 10-8-15
SAMPLE PART NUMBER MODEL LC-1 OPTION 1: LC-1 / L-5 / 8 / 120 CONTROL MODULE ↑ ↑↑ LIQUID LEVEL SWITCH CABLE LENGTH 120VAC 50/60 HZ INPUT POWERELECTRONIC LATCHING CONTROL MODULE SPECIFICATIONS: Coil Insulation: Class B Coil Connections: Double Male ¼” quick connect Operating Voltage (Input) Maximum Ambient Temperature: 155˚F Voltage: 120 or 240VAC Tolerance: ±15% OUTPUT POWER CONTACTS Frequency: 50/60 Hz Type: DPST - Normally OpenOUTPUT Contact rating per pole: Terminal Strip - 812 Series Electromechanical relay Electrical Rating Form: Single pole double throw, isolated Rated voltage - 1600 Volts RMS Rating: 10A resistive at 240VAC Current rating - 30A Wire SizePROTECTION Will accommodate lugs for wire sizes AWG #14 to 12 Hardware Transient Protected Screws and terminals - brass, nickel plated Dielectric Breakdown: 1500 volts RMS minimum between Solder terminals - brass, hot-tinned Molded Material input, output and probe. G.P. Phenolic (94V-0).ENVIRONMENT Complete operating instructions, mechanical and electrical installation drawing and a numbered parts list is supplied with each unit. Operating Temperatures: -20˚C to +55˚C Storage Temperatures: -20˚C to +55˚C HOW TO ORDER: Coating: Printed circuit board is conformal coated to Four items are required to order a complete control system: resist moisture and corrosion. 1. Basic Model Number: LC-1 and liquid level switches. 2. Level Switch Model Number: Standard cable is ¼” O.D. SVJMOTOR CONTACTOR SPECIFICATIONS 18-2/90˚C UL listed. Note: if Choose from 15 standard customer is to supply cable,OPERATING COIL models. enter “O” 3. Length of cable in feet 4. Operating Voltage. 120VAC or 208–240VAC 50/60 HZ between control module Inrush: 31 VA Continuous use: 7 VA Pickup: 90VAC (120VAC Coil) 170VAC (208-240 VA Coil) PHENOLIC BASEBOARD 8⁄ ” ELECTRONIC MOTOR LATCHING CONT- CONTROL ACTOR MODULE TERMINAL STRIP AC INPUT AC OUTPUT POWER POWER 8⁄” 4⁄ ” LIQUID LEVEL SWITCH ¼” O.D. 18/2 CABLE ALL LEVEL SWITCHES FITTED WITH DMP/A GROMMET CABLE CONNECTOR. CABLE IS ¼” O.D. 18/2 OTHER CABLE TYPES & SIZESAVAILABLE BY SPECIAL ORDER 37 10-8-15
CONTROLLER MODEL SDC-101THE PROBLEM situation, i.e. lack of flow at start up will not allow the flow switch to supplyFailure to establish programmed flow after pump turn on signal has been power to the pump. A manual push to start or automatic time delay relayapplied. switch in parallel with the flow switch is required to supply power to the pump motor during startup. After the pump is up to speed the parallelFailure to maintain proper flow during normal operation due to line switch kicks out and the flow switch takes over flow monitoring. Modelclogging, line rupture, incorrect valve positioning, etc. SDC-101 is provided with a parallel variable time delay relay switch/flow switch combination to provide pump protection during startup as well asTHE SOLUTION the continuous phase of operation.Insertion of an SDC-101 shut down control in the input power line ofpumps, heaters, valves, etc., that are flow critical will interrupt power SDC-101 modules may be connected to monitor:automatically upon loss of flow. Critical points in simple one pump systems or, in series, with pumps,Power will remain off until the problem has been corrected and proper heaters, valves, etc., so that failure of any part will shut the whole systemflow re-established. down.Loss of pump prime is a persistent fluid system problem. A flow switch at Isolated or remote components andthe pump output is a viable solution, except that it presents a “catch 22” sub-systems.TYPICAL USES Sanitation Aerospace ground support systemsFor use in: Mining Chemical Processing Transportation Food Processing Water Treatment AgricultureADDITIONAL FEATURES: LINE CLOGGINGContinuous adjustment of time delay INPUT AUTOMATIC POWERcycle. POWER SEQUENCE COMPUTER120/240VAC and DC power options MICROPROCESSOR PUMP HEATER MANUALRain resistant housing for rugged,industrial usage PUMP FAILURE LINE RUPTURECan be used in mobile vehicles, ships,trains, etc.OPERATIONAL FEATURES: POWERSupplied pre-wired and ready for immediate PUMP HEATERinstallation SDC-101 FLOWAll components UL listed or recognized SWITCHInput and output power lines are quickly andeasily attached to 30A terminal blockTerminal block positions are numbered andwiring is color coded for easy, fast andaccurate installation and servicing.Performance checks are quick and straight-forward using an uncomplicated, standardmultimeter. START SEQUENCE AUTOMATIC SEQUENCER COMPUTER MICROPROCESSOR MANUAL 38 10-8-15
SPECIFICATIONS: MODEL SDC-101Control BoxRain resistant type 3R - UL listed. THUMBWHEEL ADJUSTED POWER RELAY POWER IS SUPPLIED TO THE PUMP IMMEDIATELY ON START UP. THE TIME DELAY IS VARIABLE TIME DELAY ALSO INITIATED WHICH THEN OPENS THE PARALLEL BYPASS SWITCH AT END OF THE DELAY PERIOD. TIME DELAY RELAY8 1/8” TIME DELAY PHENOLIC RELAY BASEBOARD FLOW SWITCH FLOW SWITCH KICKS IN TO SUPPLY POWER PUMP TO PUMP BEFORE TIME DELAY SWITCH 8 1/8” 4 3/16” KICKS OUT. THREE ¼” SEALFLEX 120 ORHARWIL STRAIN RELIEF WATERTIGHT CONNECTORS 240 AC POWERCONNECTOR & 6 FT. OF 2 CONDUCTORPOWER CABLE IF PUMP FAILS TO INITIATE FLOW ON START UP, PUMP POWER IS IMMEDIATELY SHUT OFF. IF PUMP IS ESTABLISHED AT START UP BUT IS LOST AT A LATER TIME, PUMP POWER IS SHUT OFF.TIME DELAY RELAY SWITCH PERFORMANCE DATAOperation Refer to manufacturer’s specification sheets for information regarding performance of:When rating voltage is applied to the input, the timing cycle begins andthe DPDT relay is activated. At the end of the timing cycle, the relay is • Harwil Fluid Flow switchesde-activated and remains in that condition until power is removed from the • Harwil Air Flow switchesinput. Switching off and then turning on of input power re-starts the timing • Pressure switchescycle. This timing sequence will repeat each time the system is turned on. • Motion Limit switches • Proximity Switches, etc. which may be used in • Input Voltage - 120/240VAC, 50/60 Hz • Output Contact Arrangement - DPDT conjunction with, but are not included with, the • Contact Rating SDC-101 module. • 10A, ½ hp @ 120/240VAC, 50/60 Hz • Standard Time Cycle Complete operating instructions. Mechanical and Electrical installation • 1 to 180 sec., Continuously adjustable drawing and a numbered parts list is supplied with each unit. • Ambient Operating Temp. Range -5˚ to 140˚F • Termination - ¼” quick disconnect terminals Super-simple maintenance and checkout for personnel using a standard test meter.MOTOR CONTACTOR SPECIFICATIONS Terminal Strip - 812 SeriesOPERATING COIL ELECTRICAL RATING • 120VAC or 208-240VAC 50/60 Hz • Rated voltage - 1600 Volts RMS • Inrush: 31 VA • Current rating - 30A • Continuous Use: 7 VA • Pickup: 90VAC (120VAC Coil) WIRE SIZE • 170VAC (208 VA Coil) • Will accommodate lugs for wire sizes AWG #14 • Coil Insulation: class B to #12 • Coil Connections: Double Male ¼” quick connect • Maximum Ambient Temperature: 155˚ HARDWARE • Screws and terminals - brass, nickel platedOUTPUT POWER CONTACTS • Solder terminals - brass, hot-tinned • Type: DPST - Normally Open MOLDED MATERIAL • Contact rating per pole. • G.P. phenolic (94V-0). • UL Recognized 39 10-8-15
INTRINSICALLY SAFE SOLID SERIES 27STATE HAZARDOUS AREA RELAYALLOWS USE OF STANDARD, OFF-THE-SHELF SWITCHES IN HAZARDOUS AREAS SAFE SAFE NON-HAZARDOUS AREA AREA AREA INTRINSICALLY SAFE RELAYS INTRINSICALLY INTRINSICALLY RELAY RELAY RELAY SAFE RELAYS SAFE RELAYS FLUID FLOWS SNAP ACTION SPEED LIQUID LEVEL REED POSITION TEMPERATURE BLADE LIMIT CONDUCTIVITY PUSHBUTTON PROXIMITY PRESSURE HAZARDOUS AREA FLOW SWITCH FLOAT SWITCH HAZARDOUS AREASWHAT IS INTRINSICALLY SAFE?Intrinsically safe equipment and wiring is equipment and wiring which is incapable of releasing sufficient thermoelectric energy to cause ignition of ahazardous atmospheric mixture of gases, vapors, or dusts. Intrinsically safe electrical equipment and wiring may be installed in any hazardous location ofany group classification for which it is accepted without requiring explosion-proof housings or other means or protection.OPERATIONAL FEATURES: • Modern, cost effective, solid state technology eliminates expensive, old style, explosion proof enclosures. • Installation and maintenance of equipment is fast, simple, and inexpensive. • Long-term safety and reliability is increased substantially by elimination of sealed joints, special housings, and gaskets. • Epoxy encapsulation of solid state circuitry provides protection against harsh industrial environments. • Immunity to normal shocks, vibrations, thermal expansion, and contraction.SINGLE UNIT PROVIDES TWO MODES OF OPERATION FOR LIQUIDLEVEL APPLICATIONS 1. Single Non-Latching Input for high or low level alarm. 2. Dual Latching Input for Pump Up/Pump Down liquid level control.APPROVED FOR USE IN THE FOLLOWING HAZARDOUS AREAS:CLASS 1 AND 2 DIVISION 1 GROUPS A, B, C, D, E, F, AND GCLASS 3Approved: Factory Mutual System and U.L.Versatile Single and Dual Input Switching Logic also allows one Unit to be Usedin a Multitude of Alarm and Control Applications, Such as: Fluid Flow Pressure Temperature Limits Speed Proximity Conductivity Position 40 10-8-15
SPECIFICATIONS SERIES 27 Contact Design: SPDT One normally open (N.O.) and 7/32 THRU One normally closed (N.C.) 4 3/8CONTACT RATINGS 8A resistive load at 120/250VAC and 8A at 30VDC 3 2 1/8 3 3/8CONTACT LIFE Electrical at rated load = 100,000 cycles. Mechanical - 10,000,000 cyclesELECTRONIC MODULE Solid State components epoxy encapsulated in nylon shell.PRIMARY (A.C. SUPPLY LINE) Voltage: 120 or 240VAC, plus 10% minus 15% Frequency: 50/60 Hertz Power: Relay energized 2.2 watts Secondary Nominal Voltage 11.3VAC, 2.3 mASENSITIVITY Operates from 0 - 100,000 ohm maximum specific resistance.TEMPERATURE -40˚ to 150˚F ambient. Terminals: Size 6 pan head screws with captivated wire clamping plate. Single Input (Non-Latching) Pilot Contact ActuatedNOTE: Jumper must be installed as shown to insure proper operation. ENCLOSURELOAD C NO NC AC AC G1 JUMPERG HL GFIELDLOAD WIRING EARTH BETWEENVAC GROUND RELAY AND PILOT DEVICE SEALING FITTING PILOT DEVICE ENCLOSURELOAD C NO NC AC AC G1 G HL G FIELDLOAD WIRING BETWEENVAC RELAY AND PILOT EARTH DEVICE GROUND SEALING LATCH FITTING (G,H) UNLATCH LATCH (G,L) PILOT DEVICE UNLATCH PILOT DEVICE 41 10-8-15
EPOXY AND PTFE COATINGS OF FLUIDFLOW AND LIQUID LEVEL SWITCHESLONG-TERM PROTECTIVE COATINGSAll metal wetted materials of our fluid flow switches (Models Q-1, Q-4E, Q-5, Q-5SS, QD Series) and liquid level switches (Models L-5,L-5SS, LD series) are now available with baked on epoxy or PTFE (Polytetrafluoroethylene)* coatings.PTFE coatings are similar to the non-stick coatings commonly found on household cookware, from spoons to frying pans. These plasticcoated surfaces provide greater long-term protection against chemical corrosive attack of virgin metal substrate, such as brass, 316 Stain-less, or Hastelloy C.Plastic coated surfaces also provide protection on the other end of the scale, (e.g. leaching of alloy components from brass by ultra-purewater). The coating of low cost substrate metals to provide superior chemical resistance is thus a cost effective solution of special situa-tions where all plastic or exotic metal solutions are not available at any reasonable price, or time scale. These epoxy and PTFE coatingsprovide increased protection against:• Chloric Acid • Sea Water• Chromic Acid • Sewage• Contaminated Water • Skydrol• Ferric Chloride • Sulfuric Acid• Gasoline • Ultra-Pure Water• Hydrocarbons • Waste Waters• Hydraulic Acid• NaOH• Nitric AcidCOATINGS AVAILABLEEverlube 6108 thermal cured PTFE.Everslik 1201 thermal cured epoxy.PIN HOLES AND SCRATCHESAll coating of metal substrate for corrosion protection from automobiles to super tankers is subject to imperfections such as pin holes and scratches. Dili-gent adherence to mil spec quality procedures and careful handling minimizes these effects.DELIVERYA small quantity (10 to 50) of epoxy coated parts of all standard models are normally in stock for immediate delivery. Larger quantities of epoxy andPTFE coated parts are normally available within 4-6 weeks.HOW TO ORDERAll standard fluid flow and liquid level switch models with exposed metal surfaces are available with EPOXY or PTFE coating of these surfaces.Adding EC (epoxy coating) or PTFE to the end of a model number is all that is required.EXAMPLESUNCOATED MODEL NO: Q-1 / 3 / F COATED MODEL NO: Q-1 / 3 / F / EC COATED MODEL NO: L-30CR / A / PTFEUNCOATED MODEL NO: L-30CR / A WARRANTYThe Epoxy Coating No. 1201 & PTFE Coating No. 6060 are guaranteed to be applied per mil spec procedures.Coatings cannot be guaranteed to be free of pin holes and scratches, however all coatings are subject to written QC procedures and are 100% visuallyinspected for pin holes and scratches. All units with visible pin holes and scratches are rejected. 42 10-8-15
CHEMICAL RESISTANCE CHART FOR VARIOUS PUMP MATERIALSThe recommendations listed on the following pages are based upon information from material suppliers and careful examination of available informa-tion and are believed to be accurate. However, since the resistance of metals, plastics, and elastomers can be affected by concentration, temperature,presence of other chemicals and other factors, this information should be considered as a general guide rather than an unqualified guarantee. Ultimatelythe customer must determine the suitability of the pump used in various solutions.All recommendations assume ambient temperatures unless otherwise noted. The ratings for these materials are based upon the chemical resistance only.Added consideration must be given to pump selections when the chemical is abrasive, viscous in nature, or has a specific gravity greater than 1:1.How to use this chart: Column at left lists chemicals in alphabetic order. Columns at right list various pump materials, and their resistance to the chemicalsare rated by a letter code. Chemical Effect Ratings FOOTNOTES A – NO EFFECT - ACCEPTABLE 1. P.V.C. - Satisfactory to 72°F B – MINOR EFFECT - ACCEPTABLE 2. Polypropylene - Satisfactory to 72°F C – MODERATE EFFECT - QUESTIONABLE 3. Polypropylene - Satisfactory to 120°F D – SEVERE EFFECT - NOT RECOMMENDED 4. Buna-N - Satisfactory for “O” Rings * – NOT TESTED 5. Polyacetal - Satisfactory to 72°F 6. Ceramag - Satisfactory to 72°FThe performance comments and limitations listed above are supplied by Harwil Corporation for information only. Ultimately the customer must determinethe suitability of Harwil Corporation products used in various solutions, situations and environments. 304 STAINLESS STEEL 316 STAINLESS STEEL ALUMINUM TITANIUM HASTELLOY C BRONZE BRASS PVC (TYPE 1) TEFLON NORYL POLYPRPYLENE FORTRON VITON BUNA N ETHYLENE PROPYLENE EPOXY 304 STAINLESS STEEL 316 STAINLESS STEEL ALUMINUM TITANIUM HASTELLOY C BRONZE BRASS PVC (TYPE 1) TEFLON NORYL POLYPRPYLENE FORTRON VITON BUNA N ETHYLENE PROPYLENE EPOXYA Isobutyl A A B A A A C ** A A * A C A AAcetaldehyde5 IsopropylAcetamide * *A A B A A D Methyl6 A A B A A A C ** A A * A C A AAcetate Solv.2 DA BADB BA OctylAcetic Acid, Glacia1 PropylAcetic Acid 20% B A ********** A A A A Aluminum Chloride 20% *A A B A A A C B A A A CBAAAcetic Acid 80% Aluminum ChlorideAcetic Acid B A B ** A C B A * D * D D * A Aluminum Fluoride A A A A A A C ** A ** A B A AAcetic Anhydride Aluminum Hydroxide6Acetone6 BABAACCCACBADDB B Alum Potassium Sulfate * *A A A A A A AAAAAcetyl Chloride (Alum), 10% AAAAAcetylene2 Alum Potassium SulfateAcrylonitrile B A*A A*C B A A A A A C*B (Alum), 100% * *D C B A A D A A A A A A A AAlcohols Aluminum Sulfate B A*A A*C D A B B*A C*B Amines * *D C D C A C Amyl Ammonia 10% AAAAAAA A Benzyl Ammonia, Anhydrous Butyl B A B AACCAAAAACC B A Ammonia, Liquids D C * D B ** A A A A * A A * A Diacetone2 Ammonia, Nitrate Ethyl AA B AACDDADAADA B A Ammonium Bifluoride A A A ** A * A A A A * A A * A Hexyl Ammonium Carbonate AAAAAAADAD B ADDA B C A *** D ** A ** A A ** A A * A * B ** A A *** A ** A A A A B * B * B ** D A A A A A D A B*B C*A A A A*A A*A A C B B B A **** B A C D D A CCAAACCAAAAAAAAA A A A B A B * C A B ** D D B A AACAAA B AAC B AAAAA * A * A A ** A A A A A A D * B * *A A B A A A C D ADBA AA *B A B B A D AAAA B D B AA AAB BABCAAABAAAAA A A D*B D*A A A A*D B A A * *A A A A A A C D DDAA AD * *A A B A A A C A A A C ** D * B * A A ** A * A AA AABA A A A A A A C ** A A * A A A A C A D * B ** A * A A * A A * A * *A A C A B B B DAA AAAA 43 10-8-15
304 STAINLESS STEEL 316 STAINLESS STEEL ALUMINUM TITANIUM HASTELLOY C BRONZE BRASS PVC (TYPE 1) TEFLON NORYL POLYPRPYLENE FORTRON VITON BUNA N ETHYLENE PROPYLENE EPOXY 304 STAINLESS STEEL 316 STAINLESS STEEL ALUMINUM TITANIUM HASTELLOY C BRONZE BRASS PVC (TYPE 1) TEFLON NORYL POLYPRPYLENE FORTRON VITON BUNA N ETHYLENE PROPYLENE EPOXYAmmonium Casenite * A ******* A ***** A Butylene B A A ** A A B A ** A A B D AAmmonium Chloride ACCDADCAAAAAAAAA Butyl Acetate1 *C A*A A*D A D D A D B B AAmmonium Hydroxide A A C A A D D A A A A A B B A A Butyric Acid1 * *B A B A A C DDBA Butyl Acetate BAAAAmmonium Nitrate AABAADDAAAAADAAA B A C A A C * A A A A * A A **Ammonium Oxalate A A**A********A*A Butyric Acid A A C A A C*A A A A*A A*AAmmonium Persulfate * *A A C C A A CAAA AAAA CAmmonium Phosphate,Dibasic * *A A B A A C AAAA D A D ** D D A A *** A A * AAmmonium Phosphate, AAAA Calcium BisulfateMonobasicAmmonium Phosphate, * *A A B A A D Calcium Bisulfide *B C A A C*A A A A*A A D ATribasic AAAA AAAA Calcium Bisulfite B A C A A C * A A A A * A A **Ammonium Sulfate * *A A B A A C AAAA AAAA A A C A A C*A A A A*A A*A B A * B B C * A A *** A ** A DB BAABCAAAAADAAA Calcium Carbonate Calcium ChlorateAmmonium Thio-Sulfate * A * A * * * * * * * * * A * A Calcium Chloride *A D C A A B AAAAAAAAAAmyl-Acetate *A A B A A C DADDADDAA Calcium Hydroxide * *A A C A A B AAAA AAAA * *A A B A A AAmyl Alcohol AACA B BAA * *Calcium Hypochlorite D C C A B D DAAA ABAAAmyl Chloride C B D*A A*D A D D*A D D A * *A A B A B B Calcium Sulfate AAAAAAA AAniline *A A C A B C DAD B ACD B A Calgon A A *** C *** A A * A A * AAnti-Freeze *A A A AB BAAAAAAAAA Cane Juice2 A A B ** B C A ** D ** A * A ****************Antimony Trichloride D D D C A ** A A *** A ** A Carbolic Acid (See A A A ** C * D ** D * A D D A Phenol)Aqua Regia (80%, * *D D D A D D CDDDHCl, 20%, HNO) DADC Carbon Bisulfide2Arochlor 1248 ********* D **A D B A Carbon Dioxide (wet) A A C* A C C* A ******* CarbonDisulfide2Aromatic * A A ** A * D * D ** A D D A * *B A C CCDADDAADDAHydrocarbonsArsenic Acid A A D ** D B A A A A * A A * A Carbon Monoxide A A A **** A * B A * A A A AAsphalt B A C ** A * A ** A A A B D A *Carbon Tetrachloride2 1 B B C A A C A C A D D C A C CB Carbonated Water A A A ** B * A * A A * A A A ABarium Carbonate A A B A A B*A A A A*A A*A Carbonic Acid A B A*A B*A A A A*A B A ABarium ChlorideBarium Cyanide *D A D A A B AAAAAAAAA Catsup A A D ** C * A * A A * A A * ABarium HydroxideBarium Nitrate * A ***C****** A C A A Chloracetic Acid2 D D C A A D*A A*D*D D B BBarium SulfateBeet Sugar Liquids *C A D B B B AAAAAAAAA Chloric Acid D D ***** D A **** D * DBenzaldehyde3Benzene2 A A * A * D * B * A ** A A A B Chlorinated Glue A A D ** C *** C ** A C B ABenzoic Acid2 ChlorineBenzol *A A D A A C AAAAAAAABBorax (Sodium Borate) Anhydrous LiquidBoric Acid A A A ** A B A A A A * A A A A *D D D D A D DAADCADB BBrewery SlopBromine2 (wet) *A A B A A A DADDADDAA Chlorine (dry) A A D D A A B * A ** C D ** DButadieneButane2 1 AABAB BADADDAADDA Chlorine Water * D D A B D D A A C D C A D **ButanolButter * *A A B A A B ChlorobenzeneButtermilk AAAD ADDA (Mono) * *A A B DADDAADDA AB Chloroform * *A A B A A B A D A D A DD A *A A D A A B DADDCADDA AAC B AA B AAAAAA B AA Chlorosulfonic Acid1 * *D D A B D C A D D D D D D C Chlorox (Bleach) *A A B A A B C A A A A AAAA * *A A C *A***A******A A*A AA AAADCAC B A *D D D A A C BADDDADDC Chocolate Syrup A A A ****** A A * A A * A Chromic Acid 5% A A A ** C A A A ** B A A A A *A A C A A D D A CAAADA B * *A A A AAAADDAAADA Chromic Acid 10% B ** A A * D A A A A * A D * C Chromic Acid 30% B ** A A * D A A D A * A D * D A A A * A A ** A ******* Chromic Acid 50% Cider B BCAADDBADB BADAC B A A ** D *** B ** A A A A A A B ** A * A * A ** A A * A A A A ** D ** A A ** A A * A Citric Acid *A A C A A D C A A A B ADAA 44 10-8-15
Search