TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT3017-V Remote I/O module Voltage Analog input wiring Input 3 Input 0 Input 1 Input 2 8 channel +/-10 V input on RS-485 networkINPUT TYPE INPUT MAX INPUT CALIBRATION (1) POWER SUPPLY Input 4 Input 5 Input 6 Input 7VOLTAGE MIN +/- 10 mV Supply Voltage10 V 10..30 Vdc NOTE: input channels are not isolated between them -10 V 2 4 6 8 10 12 14 16 = Ref. Current consumption 30 mA @ 24 Vdc +10 V Polarity inversion protection 60 Vdc max LINEARITY (1) +/- 0.1% INPUT IMPEDANCE ISOLATION 2000 Vac, 50 Hz, 1 min. RS-485 network wiring RS-232 network wiring > 100 K Ω IInput - RS485 2000 Vac, 50 Hz, 1 min. RETE RS - 232 Supply - Input 2000 Vac, 50 Hz, 1 min. RS - 485 Supply - RS485 THERMAL DRIFT (1) Full Scale ± 0.005% / °C Power supply wiring INIT wiring ON: short-circuit SAMPLE TIME TEMPERATURE AND HUMIDITY to GND 0.5÷2 sec. Operating temperature -10°C .. +60°C Storage temperature -40°C .. +85°C Humidity (not condensed) 0 .. 90% Struttura Isolamenti DATA TRANSMISSION (async. serial) EMC (for Industrial Environments) Analog RS485 Baud-rate 38.4 Kbps inputs (RS232) Max. distance 1.2 Km-4000 ft. Immunity EN 61000-6-2 Emission EN 61000-6-4 Power supply DAT3018 (1) Referred to input Span (difference between max. and min. values) Voltage Analog input wiring Remote I/O module Input 0 Input 1 Input 2 Input 3 8 channel mV, Tc input on RS-485 network Input 4 Input 5 Input 6 Input 7 INPUTINPUT TYPE MIN MAX INPUT IMPEDANCE POWER SUPPLY Termocouple +1200°C Tc,mV >= 1 MΩ (2) Supply Voltage 10..30 Vdc Input 0 Input 1 Input 2 Input 3 +1370°C Current consumption 30 mA @ 24 VdcTHERMOCOUPLE +1760°C Polarity inversion protection 60 Vdc maxJ -210°C +1760°CK -210°C +1820°C LEAD WIRE RESISTANCE INFLUENCE Input 4 Input 5 Input 6 Input 7S -50°C +1000°C Tc, mV <= 0.8 uV/Ohm (1)R -50°C +400°CB +400°C +1300°C THERMAL DRIFT ISOLATION 2000 Vac, 50 Hz, 1 min. NOTE: input channels are not isolated between themE -210°C Full Scale ± 0.005% /°C (1) Input - RS485 2000 Vac, 50 Hz, 1 min.T -210°C Supply - Input 2000 Vac, 50 Hz, 1 min.N -210°C Supply. - RS485 2 4 6 8 10 12 14 16 = Ref.VOLTAGE -25 mV +25 mV CJC THERMAL DRIFT RS-485 network wiring RS-232 network wiring25 mV -100 mV +100 mV100 mV -250 mV +250 mV Full Scale ± 0.02% °C RS - 485 RS - 232250 mV -1000 mV +1000 mV network1000 mVINPUT CALIBRATION SAMPLE TIME TEMPERATURE AND HUMIDITY Power supply wiring INIT wiring> +/- 0.05% or 5 uV (1) 0.5÷2 sec. Operating temperature -10°C .. +60°C ON: short-circuit Storage temperature -40°C .. +85°C to GND Humidity (not condensed) 0 .. 90%LINEARITY +/- 0.1% (1) DATA TRANSMISSION (async. serial)mV +/- 0.2% (1) Baud-rate 38.4 KbpsTc Max. distance 1.2 Km - 4000 ft. Isolation structure EMC (for Industrial Environments) Analog RS485COLD JUNCTION COMPENSATION WARM-UP TIME Immunity EN 61000-6-2 inputs (RS232) ± 0.5°C 3 minutes Emission EN 61000-6-4 Power supply(1) refered to input Span (difference between max. e min. values) (2) there is a pull-up resistor (10 MΩ) connected to + 1V circa (break sensor) Mechanical dimensions (mm)62

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT3019 Remote I/O module Analog input wiring 8 channel RTD input on RS-485 network RTD, Res. Input 1 Input 2 Input 3 Input 0 Input 4 Input 5 Input 6 Input 7INPUT TYPE INPUT MAX INPUT CALIBRATION (1) POWER SUPPLY MIN RTD 850°C 200°C +/- 0.2% f.s. Supply Voltage 10..30 Vdc NOTE: input channels are not isolated between them 180°C Res. +/- 0.2% f.s. 2 4 6 8 10 12 14 16 = Ref.RTD 2 wires 150°C Current consumption 30 mA @ 24 VdcPt100Pt1000 -200°C Polarity inversion protection 60 Vdc maxNi100 -200°CNi1000 -60°C LINEARITY (1) RS-485 network wiring RS-232 network wiring -60°C RTD +/- 0.2% f.s. RS - 485 network RS - 232RES. 2 wires RTD EXCITATION CURRENT ISOLATION 2000 Vac, 50 Hz, 1 min. Power supply wiring INIT wiringLow 0 Ω 500 Ω TYPICAL 0.450 mA Input - RS485 2000 Vac, 50 Hz, 1 min.High 0 Ω 2000 Ω Supply - Input 2000 Vac, 50 Hz, 1 min. Supply - RS485 THERMAL DRIFT (1) ON: short-circuit FULL SCALE ± 150 ppm/°C to GND SAMPLE TIME TEMPERATURE AND HUMIDITY 0.5÷2 sec. Operating temperature -10°C .. +60°C Storage temperature -40°C .. +85°C Humidity (not condensed) 0 .. 90% Isolation structure DATA TRANSMISSION (async. serial) Baud-rate Max. distance 38.4 Kbps Analog RS485 1.2 Km - 4000 ft. inputs (RS232) WARM-UP TIME EMC (for Industrial Environments) Power supply 3 minutes Immunity EN 61000-6-2 Emission EN 61000-6-4(1) Referred to input Span (difference between max. and min. values) DAT3022 Remote I/O module Analog otput wiring 2 channel V/mA output Current on RS-485 network VoltageOUTPUT TYPE MIN MAX AUXILIARY VOLTAGE POWER SUPPLYVOLTAGE > 12 V @ 20mA (2 channels) Supply VoltageV 18..30 Vdc 0 V +10 V Current consumption 35 mA @ 24 Vdc tip. 60 mA max Polarity inversion protection 60 Vdc max RS-485 RS-232CURRENT RS - 232mA 0 mA +20 mA RISE TIME RS - 485 Analog output Slew-rate network (independent programmation for each channel)OUTPUT CALIBRATION VOLTAGE CURRENT ISOLATION 2000 Vac, 50 Hz, 1 min.Voltage ± 10 mV V/s mA/s Input - RS485 2000 Vac, 50 Hz, 1 min. Power supply wiring INIT wiring Supply - Input 2000 Vac, 50 Hz, 1 min.Current ± 20 µA 0.125 0.250 Supply - RS485 ON: corto circuito 0.250 0.500 verso GND 0.500 1.000LOAD RESISTANCE > 5 KΩ 1.000 2.000 TEMPERATURE AND HUMIDITYVoltage 2.000 4.000 Operating temperature -10°C .. +60°C 4.000 8.000 Storage temperature -40°C .. +85°C Immediate Immediate Humidity (not condensed) 0 .. 90%Current < 500 Ω Isolation Structure Analog RS485 outputs (RS232)THERMAL DRIFT 100 ppm max DATA TRANSMISSION (async. serial) EMC (for Industrial Environments)Full scale Baud-rate Immunity Max. distance 115,2 Kbps EN 61000-6-2 1,2 Km - 4000 ft. Emission EN 61000-6-4 Power supply Mechanical dimensions (mm) 63

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT3024 Remote I/O module Analog output wiring 4 channel V/mA output on RS-485 network Current VoltageOUTPUT TYPE MIN MAX AUXILIARY VOLTAGE POWER SUPPLYVOLTAGE 0 V +10 V > 12 V @ 20mA (4 channels) Supply VoltageV 18..30 Vdc 0 mA +20 mACURRENT Current consumption 35 mA @ 24 Vdc tip.mA 100 mA max Polarity inversion protection 60 Vdc max RISE TIME Analog output Slew-rate (independent programmation for each channel)OUTPUT CALIBRATION VOLTAGE CURRENT ISOLATION 2000 Vac, 50 Hz, 1 min. RS-485 RS-232 V/s mA/s Input - RS485 2000 Vac, 50 Hz, 1 min. RS - 232Voltage ± 10 mV Supply - Input 2000 Vac, 50 Hz, 1 min. RS - 485Current Supply - RS485 network ± 20 µA 0.125 0.250 0.250 0.500 0.500 1.000 Power supply wiring INIT wiring 1.000 2.000LOAD RESISTANCE > 5 KΩ 2.000 4.000 TEMPERATURE AND HUMIDITY ON: short-circuitVoltage 4.000 8.000 Operating temperature -10°C .. +60°C to GND Immediate Immediate Storage temperature -40°C .. +85°C Humidity (not condensed) 0 .. 90%Current < 500 Ω Isolation structureTHERMAL DRIFT 100 ppm max DATA TRANSMISSION (async. serial) EMC (for Industrial Environments) Analog RS485Full scale Baud-rate Immunity outputs (RS232) Max. distance 115.2 Kbps EN 61000-6-2 1.2 Km - 4000 ft. Emission EN 61000-6-4 Power supply DAT3028 Remote I/O module Analog output wiring 8 channel 0-10 V output Voltage on RS-485 networkOUTPUT TYPE MIN MAX RISE TIME POWER SUPPLYVOLTAGE 0 V +10 V Analog output Slew-rate Supply VoltageV (independent programmation for each channel) 18..30 Vdc VOLTAGE Current consumption 35 mA @ 24 Vdc tip. V/s Polarity inversion protection 60 Vdc max 0.125OUTPUT CALIBRATION ± 10 mV 0.250 ISOLATION 2000 Vac, 50 Hz, 1 min. RS-485 RS-232 0.500 Input - RS485 2000 Vac, 50 Hz, 1 min. RS - 232 1.000 Supply - Input 2000 Vac, 50 Hz, 1 min. RS - 485 2.000 Supply - RS485 network 4.000 ImmediateLOAD RESISTANCE > 5 KΩ Power supply wiring INIT wiring DATA TRANSMISSION (async. serial) TEMPERATURE AND HUMIDITY ON: short-circuit Baud-rate Operating temperature -10°C .. +60°C to GND 115.2 Kbps Storage temperature -40°C .. +85°C Max. distance 1.2 Km - 4000 ft. Humidity (not condensed) 0 .. 90%THERMAL DRIFT Isolation structureFull scale 100 ppm max EMC (for Industrial Environments) Analog RS485 Immunity outputs (RS232) EN 61000-6-2 Emission EN 61000-6-4 Power supply Mechanical dimensions (mm)64

“DAT6000 SERIES”: The DAT6000 series devices are anA/D INTERFACE evolution in the connection techniquesMODULES FOR PLC of the analog signals to the PLC. Each device amplify, linearise, filter and isolate the analog signal coming from the A/D INTERFACE MODULES FOR PLC sensors on filed and convert it in an high resolution 16 bits length “word” digital signal that is transferred to the PLC by the data line of the controller. The data transfer is controlled by the PLC trough a clock signal generated on its digital port; at each pulse of clock is transferred a bit of the data. By few and simple instructions the PLC is able to acquire more analog signals on a single digital input. Moreover each module has an Enable signal, that allows the controller to multiplexing more devices to one data line and one clock signal. The series is composed of: - Interface with 2 input channels for mV and TC (DAT6011) - Interface with 2 input channels for RTD and Resistance (DAT6012) - Interface with 2 input channels for V and mA (DAT6013) - Interface with 4 input channels for mV and TC (DAT6021) - Interface with 4 input channels for +/- 20 mA current signals (DAT6023-I) - Interface with 4 input channels for +/- 10 V voltage signals (DAT6023-V) 67

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT6011 A/D interface for PLC Analogue input connections 2 input channels for mV or Tc Voltage Voltage INPUT 0 INPUT 1 INPUT Thermocouple Thermouple INPUT 0 INPUT 1INPUT TYPE MIN MAX IMPUT IMPEDANCE POWER SUPPLYVOLTAGE mV, Tc >= 1 MΩ Power supply voltage 18 ÷ 30 Vcc50 mV -50 mV +50 mV100 mV -100 mV +100 mV Current consumption 30 mA max @ 24 Vcc500 mV -500 mV +500 mV Reverse polarity protection 60 Vcc max1000 V -1000 mV +1000 mV THERMAL DRIFT (1) NOTE: the input channels are not isolated between them H G = Ref. FULL SCALETHERMOCOUPLE +/-0.005% / °C PLC connectionsJK CJC THERMAL DRIFTR FULL SCALES +/-0.02% / °CBE -210 °C +1200 °C INPUT LINE IMPEDANCE INFLUENCE (1) ISOLATION VOLTAGET -210 °C +1370 °C Inputs - PLCN -50 °C +1760 °C mV, Tc < 0.8 uV/Ohm 2000 Vca, 50 Hz, 1 min. -50 °C +1760 °C Power supply-inputs 2000 Vca, 50 Hz, 1 min. +400°C +1820 °C Power supply-PLC 1500 Vca, 50 Hz, 1 min. -210 °C +1000 °C -210 °C +400 °C WARM-UP TIME Power supply connections -210 °C +1300 °C 3 minutes for Tc RESPONSE TIME ~ 0.3 sec.INPUT CHANNELS 2 DIGITAL INTERFACE TEMPERATURE AND HUMIDITYINPUT CALIBRATION (1) Voltage on terminals typical 24 Vcc Operative temperature -10°C .. +60°C (30 Vcc max.) Storage temperature -40°C .. +85°CLINEARITY (1) ± 0.05% F.S. ON state > 9 Vcc Humidity (nota condensed)0 .. 90%mVTc Imput impedance Isolation structureCOLD JUNCTION COMPENSATION (ENABLE, CLK) 4.7 KOhm Minimum output load ± 0.1% (DATA) Analogue ± 0.2% 500 Ohm (2) EMC (for industrial environments) input PLC ± 0.5% °C Max. clock signal frequency500 Hz Immunity EN 61000-6-2 Emission EN 61000-6-4 Rise/fall time (Tr) < 0.2 ms Power supply(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal DAT6012 A/D interface for PLC Analog input connections 2 input channels for RTD, Res. RTD/RES. 2 wires RTD/RES. 3 wires POTENTIOMETER INPUT 0 INPUT 0 INPUT 0 INPUT INPUT 1 INPUT 1 INPUT 1 MININPUT TYPE MAX THERMAL DRIFT (1) POWER SUPPLYRTD -200 °C FULL SCALE ± 0.005% / °C Power supply voltage 18 ÷ 30 VccPt100 -200 °C +850 °C Current consumption 30 mA max @ 24 VccPt1000 -80 °C +200 °C Reverse polarity protection 60 Vcc maxNi100 -60 °C +180 °CNi1000 +150 °C INPUT LINE IMPEDANCE INFLUENCE (1) NOTE: the input channels are not isolated between them H G = Ref. RTD, Res < 0.05% / Ohm 500 Ω PLC connection 2000 ΩRESISTENCE (50 Ω max, 3 wires connections)500 Ω 100%2 KΩ 0Ω 100% ISOLATION VOLTAGE 0Ω Inputs - PLC 2000 Vca, 50 Hz, 1 min.POTENTIOMETER WARM-UP TIME Power supply-inputs 2000 Vca, 50 Hz, 1 min.< 500 Ω* 3 minutes Power supply-PLC 2000 Vca, 50 Hz, 1 min.< 2 KΩ** nominal value 0% RESPONSE TIME 0% ~ 0.3 sec. Power supply connectionsINPUT CHANNELS 2 DIGITAL INTERFACE TEMPERATURE AND HUMIDITYINPUT CALIBRATION (1) ± 0.1% F.S. Voltage on terminals 24 Vcc typical Operative temperature -10°C .. +60°C (30 Vcc max.) Storage temperature -40°C .. +85°CLINEARITY (1) ± 0.1% ON state > 9 Vcc Humidity (not condensed) 0 .. 90%Res, Pot. ± 0.2%RTD Imput impedance 4.7 KOhm Isolation structureRTD/RES. EXCITATION CURRENT (ENABLE, CLK) Minimun output load PLC (DATA) Power supply 560 Ohm (2) Analog input 0.350 mA tip. Max. clock signal EMC (for industrial environments) frequency Immunity Rise/fall time (Tr) 500 Hz EN 61000-6-2 < 0.2 ms Emission EN 61000-6-4(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal Mechanical dimensions (mm)68

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT6013 A/D interface for PLC Analog input connections 2 input channels for V, mA Voltage Voltage INPUT 0 INPUT 1 INPUT Current Current MIN INPUT 0 INPUT 1INPUT TYPE -10 mV MAX INPUT IMPEDANCE POWER SUPPLYVOLTAGE +10 mV V >= 100 KΩ Power supply voltage 18 ÷ 30 Vcc10V mA <= 50 Ω Current consumption 30 mA max @ 24 Vcc Reverse polarity protection 60 Vcc max NOTE: the input channels are not isolated between them H G = Ref.CURRENT THERMAL DRIFT (1)20 mA PLC connection -20 mA +20 mA Full scale +/-0.005% / °C ISOLATION VOLTAGE Inputs - PLC 2000 Vca, 50 Hz, 1 min. Power supply-inputs 2000 Vca, 50 Hz, 1 min. Power supply - PLC 1500 Vca, 50 Hz, 1 min. RESPONSE TIMEINPUT CHANNELS 2 ~ 0.3 sec. Power supply connectionsINPUT CALIBRATION (1) +/-0.1% F.S. DIGITAL INTERFACE TEMPERATURE AND HUMIDITYLINEARITY (1) Voltage on terminals 24 Vcc typical Operative temperature -10°C .. +60°C (30 Vcc max.) Storage temperature -40°C .. +85°C ON state > 9 Vcc Humidity (not condensed) 0 .. 90% +/- 0.1% Imput impedance 4.7 KOhm Isolation structure (ENABLE, CLK) Minimum output load PLC (DATA) Power supply 560 Ohm (2) Max.clock signal EMC (for industrial environments) Analog frequency 500 Hz Immunity input Rise/fall time (Tr) < 0.2 ms Emission EN 61000-6-2 EN 61000-6-4(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal DAT6021 A/D interface for PLC Analogue input connections 4 input channels for mV, Tc Voltage INPUT 0 INPUT 1 INPUT 2 INPUT 3 INPUT Thermocouple INPUT 3 INPUT 0 INPUT 1 INPUT 2INPUT TYPE MIN MAX INPUT IMPEDANCE POWER SUPPLYVOLTAGE mV, Tc >= 1 MΩ Power supply voltage 18 ÷ 30 Vcc50 mV -50 mV +50 mV100 mV -100 mV +100 mV Current consumption 30 mA max @ 24 Vcc500 mV -500 mV +500 mV Reverse polarity protection 60 Vcc max1000 mV -1000 mV +1000 mV THERMAL DRIFT (1) NOTE: the input channels are not isolated between them H G = Ref. FULL SCALETHERMOCOUPLE +/-0.005% / °C PLC connectionJK DERIVA TERMICA CJCR FULL SCALES +/-0.02% / °CBE -210 °C +1200 °C INPUT LINE IMPEDANCE INFLUENCE (1) ISOLATION VOLTAGET -210 °C +1370 °C Inputs - PLCN -50 °C +1760 °C mV, Tc < 0.8 uV/Ohm 2000 Vca, 50 Hz, 1 min. -50 °C +1760 °C Power supply-inputs 2000 Vca, 50 Hz, 1 min. +400°C +1820 °C Power supply-PLC 1500 Vca, 50 Hz, 1 min. -210 °C +1000 °C -210 °C +400 °C WARM-UP TIME Power supply connections -210 °C +1300 °C 3 minutes for Tc RESPONSE TIME ~ 0.5 sec.INPUT CHANNELS 4 DIGITAL INTERFACE TEMPERATURE AND HUMIDITYINPUT CALIBRATION (1) Voltage on terminals 24 Vcc typical Operative temperature -10°C .. +60°C (30 Vcc max.) Storage temperature -40°C .. +85°CLINEARITY (1) ± 0.05% F.S. ON state > 9 Vcc Humidity (not condensed) 0 .. 90%mVTc Imput impedance Isolation structureCOLD JUNCTION COMPENSATION (ENABLE, CLK) 4.7 KOhm Minimum output load ± 0.1% (DATA) Analogue ± 0.2% 560 Ohm (2) EMC (for industrial environments) input PLC ± 0.5% °C Max. clock signal Immunity EN 61000-6-2 frequency Rise/fall time (Tr) 500 Hz Emission EN 61000-6-4 < 0.2 ms Power supply(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal Mechanical dimensions (mm) 69

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT6023-I A/D interface for PLC Analogue input connections 4 input channels for Current Current INPUT 0 INPUT 1 INPUT INPUT 2 INPUT 3 MININPUT TYPE MAX IMPUT IMPEDANCE POWER SUPPLYCURRENT -20 mA +20 mA mA <= 50 Ω Power supply voltage 18 ÷ 30 Vcc20 mA Current consumption 30 mA max @ 24 Vcc Reverse polarity protection 60 Vcc max NOTE: the input channels are not isolated between them H G = Ref. THERMAL DRIFT (1) PLC connection FULL SCALE +/-0.005% / °C ISOLATION VOLTAGE Inputs-PLC 2000 Vca, 50 Hz, 1 min. Power supply-inputs 2000 Vca, 50 Hz, 1 min. RESPONSE TIME Power supply-PLC 2000 Vca, 50 Hz, 1 min. ~ 0.5 sec.INPUT CHANNELS 4 Power supply connectionsINPUT CALIBRATION (1) DIGITAL INTERFACE TEMPERATURE AND HUMIDITYLINEARITY (1) +/-0.1% F.S. Voltage on terminals 24 Vcc typical Operative temperature -10°C .. +60°C (30 Vcc max.) Storage temperature -40°C .. +85°C ON state > 9 Vcc Humidity (not condensed) 0 .. 90% Imput impedance 4.7 KOhm (ENABLE, CLK) +/- 0.1% Minimum output load Isolation structure (DATA) 560 Ohm (2) Max. clock signal 500 Hz EMC (for industrial enviroments) Analogue PLC frequency input Rise/fall time(Tr) < 0.2 ms Immunity EN 61000-6-2 Emission EN 61000-6-4 Power supply(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal Analog input connections DAT6023-V A/D interface for PLC Voltage 4 input channels for Voltage INPUT 0 INPUT 1 INPUT INPUT 2 INPUT 3 MININPUT TYPE MAX INPUT IMPEDANCE POWER SUPPLYVoltage -10 V +10 V V >= 100 KΩ Power supply voltage 18 ÷ 30 Vcc10 V Current consumption 30 mA max @ 24 Vcc Reverse polarity protection 60 Vcc max NOTE: the input channels are not isolated between them H G = Ref. THERMAL DRIFT (1) PLC connection FULL SCALE +/-0.005% / °C ISOLATION VOLTAGE Inputs - PLC 2000 Vca, 50 Hz, 1 min. Power supply - Inputs 2000 Vca, 50 Hz, 1 min. RESPONSE TIME Power supply - PLC 1500 Vca, 50 Hz, 1 min. ~ 0.5 sec.INPUT CHANNELS 4 Power supply connectionsINPUT CALIBRATION (1) DIGITAL INTERFACE TEMPERATURE AND HUMIDITYLINEARITY (1) Voltage on terminals 24 Vcc typical Operative temperature -10°C .. +60°C +/-0.1% F.S. (30 Vcc max.) Storage temperature -40°C .. +85°C Humidity (not condensed) 0 .. 90% ON state > 9 Vcc Input impedance 4.7 KOhm (ENABLE, CLK) Minimum output load Isolation structure +/- 0.1% (DATA) 560 Ohm (2) PLC Max. clock signal 500 Hz EMC ((for industrial enviroments) Analog Power supply frequency Input Rise/fall time (Tr) < 0.2 ms Immunity EN 61000-6-2 Emission EN 61000-6-4(1) refered to input Span (difference between max. and min. values) (2) The load on the output DATA is controlled with the current taken from the ENABLE signal Mechanical dimensions (mm)70

“DAT1000 SERIES”: The transmitters of the DAT1000 series DIN B IN-HEAD MOUNTING TRANSMITTERSTEMPERATURE can accept at their input signals comingTRANSMITTERS from 2,3 or 4 wires Pt100,ThermocoupleFOR DIN B IN-HEAD and potentiometer sensors or voltageMOUNTING signals (mV). The devices provide a 4÷20 mA two wire current loop output signal. The series is composed of devices for fixed range, devices configurable by dip-switches and PC available in standard or low profile housing. The transmitters of the DAT1000 series configurable by PC can be provided in the versions with or without galvanic isolation. Moreover is available a version of the transmitters configurable by PC developed for the use in potentially explosive atmospheres certified in according to the Directive ATEX 94/9/EC. 73

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1040 Fixed range linearised Input connections transmitter for Pt100 Pt100 3 wires Pt100 2 wiresINPUT RTD Pt100 in according to IEC 60751 Power supply/output connectionsSensor type 50 °C (122 °F) Load characteristicMinimum input Span From -50 °C (-58 °F) up to +50 °C (122 °F) Input connectionZero values From 50 °C (122 °F) up to +650 °C (1202 °F)Span values 1 mA tipExcitation current 0.05% of f.s./ohm (100 ohm max. balanced for wire)Line resistance influenceOUTPUT 4÷20 mA on current loopOutput type Positive out of scale (> 20 mA)Sensor interruption signalling 35 mAMaximum output signal See section “Load characteristic”Load resistance (Rload) 300 msResponse time (from 10 to 90% of f.s.) 3 minutesWarm-up timePERFORMANCESCalibration error ± 0.1% of f.s.Linearity error (*)Thermal drift ± 0.15% of f.s.Power supply voltage (**) 0.03% of full scale/°C 10÷32 VccElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperature -20÷70°CStorage temperatureRelative humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity DAT1030 Fixed range transmitter for ThermocoupleINPUT Thermocouple type E, J, K, N, R, S and T Output/Power supply connectionsSensor See section “Sensor Table” on DATA SHEET Load characteristicInput range 0.2 uV/ΩLine resistance influenceOUTPUT 4÷20 mA on current loopSignal Positive out of scale (> 20 mA)Burn-out signalling 35 mAMaximum output signal See section “Load characteristic”Load resistance (Rload) 300 msResponse time (from 10 to 90% of f.s.) 3 minutesWarm-up timePERFORMANCESCalibration error the bigger than ± 0.1% of f.s. or 0.2 °CLinearity error (*)Cold Junction Compensation (CJC) ± 0.1% of f.s.Thermal drift ± 0.5 °CSupply voltage (**) 0.02% of full scale/°C (per Span > 300 °C / 500 °F) 12÷32 VdcElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperature -20÷70 °CStorage temperatureRelative humidity (not condensed) -40÷85 °C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity Mechanical dimensions (mm) DIN rail mounting (DIN RAIL Option) DIN B In-head mounting Fixing screws Stirrup Fixing screw74

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)DAT1111F Low profile fixed range Input connections linearised transmitter for Pt100 Pt100 3 wires Pt100 2 wiresINPUT RTD Pt100 in according to IEC 60751 Power supply/Output connectionsSensor type 50 °C (122 °F) Load characteristicMinimum input Span From -50 °C (-58 °F) up to +50 °C (122 °F) Input connectionZero values From 50 °C (122 °F) up to +650 °C (1202 °F)Span values 1 mA typ.Excitation current 0.05% of f.s./ohm (100 ohm max. balanced for wire)Line resistance influenceOUTPUT 4÷20 mA on current loopOutput type Positive out of scale (> 20 mA)Sensor interruption signalling 35 mAMaximum output signal See section “Load characteristic”Load resistance (Rload) 300 msResponse time (from 10 to 90% of f.s.) 3 minutesWarm-up timePERFORMANCESCalibration error ± 0.1% of f.s.Linearity error (*)Thermal drift ± 0.15% of f.s.Power supply voltage (**) 0.03% of full scale/°C 10÷32 VccElectromagnetic Compatibility (EMC) (for industrial environments) immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperature -20÷70°CStorage temperatureRelative humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarityDAT1112F Low profile fixed range transmitter for ThermocoupleINPUT Thermocouple type K, J, N, R, S and T Note: terminal 3 not connected (NC)Sensor Refer to technical data sheetInput range 0.2 uV/Ω Output/Power supply connectionsLine resistance influence Load characteristicOUTPUT 4÷20 mA on current loop DIN rail mounting (Option DIN RAIL)SignalBurn-out signalling Positive out of scale (> 20 mA)Maximum output signal 35 mALoad resistance (Rload) Refer to technical data sheetResponse time (from 10 to 90% of f.s.) 300 msWarm-up time 3 minutesPERFORMANCESCalibration errorLinearity error (*) the bigger than± 0.1% del f.s. or 0.2 °CCold Junction Compensation (CJC) ± 0.1% of f.s.Thermal drift ± 0.5 °CSupply voltage (**) 0.02% of full scale / °C (per Span > 300 °C / 500 °F) 12÷32 VdcElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperatureStorage temperature -20÷70°CRelative Humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity Mechanical dimensions (mm)Zero Span DIN B in-head mounting Fixing screws Stirrup Fixing screw 75

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1110 Dip Switch programmable and Input connections linearised transmitter for Pt100 Pt100 3 wires Pt100 2 wiresINPUT RTD Pt100 in according to IEC 60751 Power supply/Output connectionsSensor type 50 °C (122 °F) Load characteristicMinimum input Span From -50 °C (-58 °F) up to +50 °C (122 °F) Input connectionZero programmability From 50 °C (122°F) up to +650 °C (1202 °F)Span programmability 1 mA Typ.Excitation current 0.05% of f.s./ohm (100 ohm max. balanced for wire)Line resistance influenceOUTPUT 4÷20 mA on current loopOutput typeSensor interruption signalling Positive out of scale (> 20 mA)Maximum output signal 35 mALoad resistance (Rload) See section “Load characteristic”Response time (from 10 to 90% of f.s.) 300 msWarm-up time 3 minutesPERFORMANCESCalibration errorLinearity error (*) ± 0.1% of f.s.Thermal drift ± 0.15% of f.s.Power supply voltage (**) ±0.03% of full scale/ °C 10÷32 VccElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperatureStorage temperature -20÷70°CRelative humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity DAT1120 Dip Switch programmable transmitter for ThermocoupleINPUT Thermocouple type J, K, N, R, S and T Output/Power supply connectionsSensor Programmable from -50÷50 °C or from -58 up to 122 °F Load characteristicZero programmability Thermocouple type K: (Version 1) from 100 up to 1370 °C or from 210 up to 2500 °FSpan programmability Thermocouple type J: (Version 1) from 100 up to 950 °C or from 210 up to 1740 °F DIN rail mounting (DIN RAIL Option) Thermocouple type R: (Version 2) from 650 up to 1760 °C or from 1200 up to 3200 °FLine resistance influence Thermocouple type S: (Version 2) from 700 up to 1760 °C or from 1290 up to 3200 °FOUTPUT Thermocouple type T: (Version 3) from 100 up to 450 °C or from 210 up to 840 °FSignal Thermocouple type N: (Version 4) from 150 up to 1300 °C or from 300 up to 2370 °FBurn-out signalling Thermocouple type B: (on request) from 900 up to 1820 °C or from 1652 up to 3308 °FMaximum output signal Thermocouple type E: (on request) from 100 up to 1050 °C or from 210 up to 1920 °FLoad resistance (Rload) 0.2 µV/ΩResponse time (from 10 to 90% of f.s.)Warm-up time 4÷20 mA on current loop Positive out of scale (> 20 mA) 35 mA See section “Load characteristic” 300 ms 3 minutesPERFORMANCES the bigger than ± 0.1% of f.s. or 0.2 °CCalibration errorLinearity error (*) ± 0.1% of f.s.Cold Junction Compensation (CJC) ± 0.5 °CThermal drift 0.02% of full scale/°C (for Span > 300 °C / 500 °F)Supply voltage (**) 12÷32 VccElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperature -20÷70°CStorage temperature -40÷85°CRelative humidity (not condensed) 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity Mechanical dimensions (mm) DIN B in-head mounting Zero Fixing screws Stirrup Fixing screw76

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)DAT1111 Dip Switch low profile programmable Input connections and linearised transmitter Pt100 Pt100 3 wires Pt100 2 wiresINPUT RTD Pt100 in according to IEC 60751 Power supply/Output connectionsSensor type 50 °C (122 °F) Load characteristicMinimum input Span From -50 °C (-58 °F) up to +50 °C (122 °F) Input connectionZero programmability From 50 °C (122°F) up to +650 °C (1202 °F)Span programmability 1 mA typ.Excitation current 0.05% of f.s./ohm (100 ohm max. balanced for wire)Line resistance influenceOUTPUT 4÷20 mA on current loopOutput typeSensor interruption signalling Positive out of scale (> 20 mA)Maximum output signal 35 mALoad resistance (Rload) Refer to technical data sheetResponse time (from 10 to 90% of f.s.) 300 msWarm-up time 3 minutesPERFORMANCESCalibration errorLinearity error (*) ± 0.1% of f.s.Thermal drift ± 0.15% of f.s.Power supply voltage (**) ±0.03% of full scale/ °C 10÷32 VccElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperatureStorage temperature -20÷70°CRelative humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity DAT1112 Dip Switch low profile programmable transmitter for ThermocoupleINPUT Thermocouple type J, K, N, R, S and T Output/Power supply connectionsSensor Programmable from -50÷50 °C or from -58 up to 122 °FZero programmability Thermocouple type K: (Versione 1) from 100 up to 1370 °C or from 210 up to 2500 °F Note: terminal 3 not connected (NC)Span programmability Thermocouple type J: (Versione 1) from 100 up to 950 °C or from 210 up to 1740 °FLine resistance influence Thermocouple type R: (Versione 2) from 650 up to 1760 °C or from 1200 up to 3200 °F Load characteristic Thermocouple type S: (Versione 2) from 700 up to 1760 °C or from 1290 up to 3200 °F Thermocouple type T: (Versione 3) from 100 up to 450 °C or from 210 up to 840 °F DIN rail mounting (Option DIN RAIL) Thermocouple type N: (Versione 4) from 150 up to 1300 °C or from 300 up to 2370 °F Thermocouple type B: (su richiesta) from 900 up to 1820 °C or from 1652 up to 3308 °F Thermocouple type E: (su richiesta) from 100 up to 1050 °C or from 210 up to 1920 °F 0,2 µV/ΩOUTPUT 4÷20 mA on current loopSignal Positive out of scale (> 20 mA)Burn-out signalling 35 mAMaximum output signal See section “Load characteristic”Load resistance (Rload) 300 msResponse time (from 10 to 90% of f.s.) 3 minutesWarm-up timePERFORMANCESCalibration errorLinearity error (*) the bigger than ± 0.1% of f.s. or 0,2 °CCold Junction Compensation (CJC) ± 0.1% of f.s.Thermal drift ± 0.5 °CSupply voltage (**) 0.02% of full scale/°C (per Span > 300 °C / 500 °F) 12÷32 VdcElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperatureStorage temperature -20÷70°CRelative humidity (not condensed) -40÷85°C 0÷90%(*) inclusive of hysteresis, linearisation error and power supply voltage variation(**) internally protected against reverse polarity Mechanical dimensions (mm)Zero Span DIN B in-head mounting Fixing screws 77

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1010 Two wire transmitter for RTD Input connections Programmable by Personal Computer mVINPUT TYPE INPUT MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME RTD/RES 2 wires RTD/RES 3 wires RTD/RES 4 wires MIN MAX 50°C RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 ms POT. 50°C Low res. > ± 0.1% f.s. or ± 0.15ΩRTD (*) 2, 3, 4 wires -200°C 50°C High res. > ± 0.2% or ± 1Ω Terminal 1 = GND InputPt100 850°C 50°C mV > ± 0.1% f.s. or ± 18 uVPt1000 -200°C 200°C OUTPUT CALIBRATION Output/Power supply connectionsNi100 -60°C 180°C Current ± 7 uA POWER SUPPLYNi1000 -60°C 150°C Power supply voltage 10..32 Vdc Input connections Reverse polarity protection 60 Vdc max mV POT. LOAD CHARACTERISTIC -RLOADVOLTAGE INPUT IMPEDANCEmV -100mV +700mV 2mV mV >= 10 MΩ LINEARITY (1) RTD ± 0.1% f.s.POTENTIOMETER 0Ω 200 Ω 10% LINE RESISTANCE INFLUENCE (1)(Nominal value) 200 Ω 500 Ω 10% mV <= 0.8 uV/OhmRES. 2, 3,4 wires 0.5 KΩ 2 KΩ 10% RTD 3 wires 0.05%/Ω (50 Ω balanced max.)Low 300 Ω RTD 4 wires 0.005%/Ω (100 Ω balanced max.)High 0Ω 2000 Ω 0Ω 10 Ω RTD EXCITATION CURRENT 200 Ω Typical 0.350 mAOUTPUT TYPE Min Max Min Span THERMAL DRIFT (1) TEMPERATURE AND HUMIDITYDirect current 4 mA 20 mA FULL SCALE ± 0.01%/°C Operative temperature -20°C .. +70°CReverse current 20 mA 4 mA Storage temperature -40°C .. +85°C 4 mA Humidity (not condensed) 0 .. 90% 4 mA BURN-OUT VALUES Max. value about 22.5 mA EMC (for industrial environments) Min. value about 3.6 mA Immunity EN 61000-6-2 Emission EN 61000-6-4 (1) referred to input Span (difference between max. and min. values) DAT1010 IS Intrinsically safe two wire transmitter for RTD DAT1010 IS/HT Programmable by Personal Computer INPUT RTD/RES 3 wires RTD/RES 4 wires MIN MAXINPUT TYPE MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME 50°C RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 ms RTD/RES 2 wires 50°C Low res. > ± 0.1% f.s. or ± 0.15ΩRTD (*) 2, 3, 4 wires -200°C 50°C High res. > ± 0.2% or ± 1ΩPt100 850°C 50°C mV > ± 0.1% f.s. or ± 18 uVPt1000 -200°C 200°C OUTPUT CALIBRATIONNi100 -60°C 180°C Current ± 7 uA POWER SUPPLYNi1000 -60°C 150°C Power supply voltage 11.. 30 Vdc Reverse polarity protection 60 Vdc max LOAD CHARACTERISTIC - RLOADVOLTAGE INPUT IMPEDANCEmV -100mV +700mV 2mV mV >= 10 MΩ Output/Power supply connections LINEARITY (1) Ex RTD ± 0.1% f.s. barrierPOTENTIOMETER 0Ω 200 Ω 10% LINE RESISTANCE INFLUENCE (1)(Nominal value) 200 Ω 500 Ω 10% mV <= 0.8 uV/OhmRES. 2, 3,4 wires 0.5 KΩ 2 KΩ 10% RTD 3 wires 0.05%/Ω (50 Ω balanced max.)Low 300 Ω RTD 4 wires 0.005%/Ω (100 Ω balanced max.)High 0Ω 2000 Ω 0Ω 10 Ω RTD EXCITATION CURRENT TEMPERATURE AND HUMIDITY OUTPUT/SUPPLY EX DATA: 200 Ω Typical 0.350 mA Operative temperature -20°C .. +70°C INPUTOUTPUT TYPE Min Max Min Span THERMAL DRIFT (1) -20°C..+85°C (’HT’vers.) Ui = 30 V Uo = 6.2 VDirect current 4 mA 20 mA FULL SCALE ± 0.01%/°C li = 100 mA lo = 100 mAReverse current 20 mA 4 mA Pi = 0,75 W Po = 500 mW 4 mA BURN-OUT VALUES Storage temperature -40°C .. +85°C Li = 0.1 mH Lo = 3.6 mH 4 mA Humidity (not condensed) 0 .. 90% Ci = 10 nF Co = 5 uF Max. value about 22.5 mA Min. value about 3.6 mA EMC (for industrial environments) T6: -20 ÷ + 55 °C Immunity EN 61000-6-2 T5: -20 ÷ + 70 °C (1) referred to input Span (difference between max. and min. values) Emission EN 61000-6-4 T4: -20 ÷ + 85 °C (‘HT’ vers.) Mechanical dimensions (mm) DIN B in-head mounting DIN rail mounting (DIN RAIL Option) Fixing screws Coperchio Stirrup Fixing screw plastico di protezione78

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1015 Two wire universal transmitter Input connections Programmable by Personal Computer mV TC INPUT RTD/RES 2 wires RTD/RES 3 wires RTD/RES 4 wiresINPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME POT. 2mV RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 msTC (CJC int./ext.) 2mV Low res. > ± 0.1% f.s. or ± 0.15Ω Terminal 1 = GND InputJ -200°C 1200°C 2mV High res. > ± 0.2% f.s. or ± 1Ω POWER SUPPLYK -200°C 1370°C 2mV mV, TC > ± 0.1% f.s. or ± 18 uV Power supply voltage 10..32 Vdc Output/Power supply connectionsS -50°C 1760°C 2mV OUTPUT CALIBRATION Reverse polarity protection 60 Vdc maxR -50°C 1760°C 2mV Current ± 7 uAB 400°C 1820°C 2mV INPUT IMPEDANCE LOAD CHARACTERISTIC - RLOADE -200°C 1000°C 2mV TC,mV >= 10 MΩT -200°C 400°C 50°C LINEARITY (1)N -200°C 1300°C 50°C TC ± 0.2% f.s. 50°C RTD ± 0.1% f.s.RTD (*) 2, 3, 4 wires 50°CPt100 -200°C 850°CPt1000 -200°C 200°CNi100 -60°C 180°CNi1000 -60°C 150°CVOLTAGE 2 mV LINE RESISTANCE INFLUENCE (1)mV -100 mV +700 mV TC, mV <= 0,8 uV/Ohm RTD 3 wires 0,05%/Ω (50 Ω balanced max.)POTENTIOMETER RTD 4 wires 0,005%/Ω (100 Ωbalanced max.)(Nominal value) 0Ω 200 Ω 10% RTD EXCITATION CURRENT 200 Ω 500 Ω 10% Typical 0.350 mA 0.5 KΩ 2 KΩ 10% CJC COMP. ± 0.5°C TEMPERATURE AND HUMIDITYRES. 2, 3,4 wires 300 Ω Operative temperature -20°C .. +70°CLow 0Ω 2000 Ω 10 Ω THERMAL DRIFT (1) Storage temperature -40°C .. +85°CHigh 0Ω Max 200 Ω FULL SCALE ± 0.01% /°C Humidity (not condensed) 0 .. 90% CJC ± 0.01% /°COUTPUT TYPE Min Min Span BURN-OUT VALUESDirect current 4 mA 20 mA 4 mA Max. value about 22.5 mA EMC (for industrial environments)Reverse current 20 mA 4 mA 4 mA Min. value about 3.6 mA Immunity EN 61000-6-2 Emission EN 61000-6-4 (1) referred to input Span (difference between max. and min. values) DAT1015 IS Intrinsically safe two wire universal transmitter Input connections DAT1015 IS/HT Programmable by Personal Computer mV TC POT. INPUT RTD/RES 3 wires RTD/RES 4 wiresINPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME 2mV RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 msTC (CJC int./ext.) 2mV Low res. > ± 0.1% f.s. or ± 0.15Ω RTD/RES 2 wiresJ -200°C 2mV High res. > ± 0.2% or ± 1ΩK -200°C 1200°C 2mV mV, TC > ± 0.1% f.s. or ± 10 uV POWER SUPPLY POT.S -50°C 1370°C 2mV OTPUT CALIBRATION Power supply voltage 11..30 VdcR -50°C 1760°C 2mV Current ± 7 uA Reverse polarity protection 60 Vdc maxB 400°C 1760°C 2mV INPUT CALIBRATIONE -200°C 1820°C 2mV TC,mV >= 10 MΩ LOAD CHARACTERISTIC - RLOADT -200°C 1000°C 50°C LINEARITY (1)N -200°C 400°C 50°C TC ± 0.2% f.s. 1300°C 50°C RTD ± 0.1% f.s. 50°CRTD (*) 2, 3, 4 wiresPt100 -200°C 850°CPt1000 -200°C 200°C Output/Power supply connectionsNi100 -60°C 180°CNi1000 -60°C 150°C Ex barrierVOLTAGE 2 mV LINE RESISTANCE INFLUENCE (1)mV -100 mV +700 mV TC, mV <= 0.8 uV/Ohm RTD 3 fwires 0.05%/Ω (50 Ω balanced max.)POTENTIOMETER RTD 4 wires 0.005%/Ω (100 Ω balanced max.)(Nominal value) 0Ω 200 Ω 10% RTD EXCITATION CURRENT 200 Ω 500 Ω 10% Typical 0.350 mA TEMPERATURE AND HUMIDITY EX DATA: 0.5 KΩ 2 KΩ 10% Operative temperature -20°C .. +70°C INPUT OUTPUT/SUPPLYRES. 2, 3,4 wires 300 Ω CJC COMP ± 0.5 -20°C..+85°C (.’HT’vers) 2000 Ω Storage temperature -40°C .. +85°CLow 0Ω 10 Ω THERMAL D±R0.I0F1T% (/1°C) Humidity (not condensed) 0 .. 90% Ui = 30 V Uo = 6.2 VHigh 0Ω Max 200 Ω FULL SCALE li = 100 mA lo = 100 mA Pi = 0.75 W Po = 500 mWOUTPUT TYPE Min Min Span CJC ± 0.01% /°C Li = 0.1 mH Lo = 3.6 mH Ci = 10 nF Co = 5 uF BURN-OUT VALUES Max. value about 22.5 mA EMC (for industrial environments)Direct current 4 mA 20 mA 4 mA Min. value about 3.6 mA Immunity EN 61000-6-2 T6: -20 ÷ + 55 °CReverse current 20 mA 4 mA 4 mA T5: -20 ÷ + 70 °C Emission EN 61000-6-4 T4: -20 ÷ + 85 °C (‘HT’ vers. ) (1) referred to input Span (difference between max. and min. values) Mechanical dimensions (mm) DIN B in-head mounting DIN rail mounting (DIN RAIL Option) Fixing screws Coperchio Stirrup Fixing screw plastico di protezione 79

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1070 Low profile two wire transmitter for RTD Input connections Programmable by Personal Computer mV POT. INGRESSOINPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME RTD/RES 2 wires RTD/RES 3 wires 50°C RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 ms Terminal 1 = GND Input 50°C Low res. > ± 0.1% f.s. or ± 0.15ΩRTD (*) 2, 3 wires -200°C 850°C 50°C High res. > ± 0.2% f.s. or ± 1Ω POWER SUPPLY Output/Power supply connectionsPt100 -200°C 200°C 50°C mV > ± 0.1% f.s. or ± 18 uV Power supply voltage 10.. 30 VdcPt1000 -60°C 180°C OUTPUT CALIBRATION Reverse polarity protection 60 Vdc max Input connectionsNi100 -60°C 150°C Current ± 7 uANi1000 LOAD CHARACTERISTIC - RLOAD mV TCVOLTAGE INPUT IMPEDANCEmV -100mV +700mV 2mV mV >= 10 MΩ LINEARITY (1) RTD ± 0.1% f.s.POTENTIOMETER 0Ω 200 Ω 10% LINE RESISTANCE INFLUENCE (1)(Nominal value) 200 Ω 500 Ω 10% mV <= 0.8 uV/OhmRES. 2, 3 wires 0.5 KΩ 2 KΩ 10% RTD 3 wires 0.05%/Ω (50 Ω balanced max.)Low 300 ΩHigh 0Ω 2000 Ω 10 Ω RTD EXCITATION CURRENT 0Ω 200 Ω Typical 0.350 mAOUTPUT TYPE Min Max Min Span THERMAL DRIFT (1) TEMPERATURE AND HUMIDITYDirect current 4 mA 20 mA FULL SCALE ± 0.01%/°C Operative temperature -20°C .. +70°CReverse current 20 mA 4 mA Storage temperature -40°C .. +85°C 4 mA Humidity (not condensed) 0 .. 90% 4 mA BURN-OUT VALUES Max. value about 22.5 mA EMC (for industrial environments) Min. value about 3.6 mA Immunity Emission EN 61000-6-2 EN 61000-6-4 (1) referred to input Span (difference between max. and min. values) DAT1075 Low profile two wire transmitter Programmable by Personal Computer INPUT RTD/RES 2 wires RTD/RES 3 wires POT.INPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 msTC (CJC int./ext.) Low res. > ± 0.1% f.s. or ± 0.15ΩJ -200°C 1200°C 2mV High res. > ± 0.2% f.s. or ± 1Ω POWER SUPPLYK -200°C 1370°C 2mV mV, TC > ± 0.1% f.s. or ± 18 uV Power supply voltage 10..30 VdcS -50°C 1760°C 2mV Reverse polarity protection 60 Vdc maxR -50°C 1760°C 2mVB 400°C 1820°C 2mV OUTPUT CALIBRATIONE -200°C 1000°C 2mV Current ± 7 uAT -200°C 400°C 2mV Terminal 1 = GND InputN -200°C 1300°C 2mV INPUT IMPEDANCE LOAD CHARACTERISTIC - RLOADRTD (*) 2, 3 wires 850°CPt100 -200°C 200°C 50°C TC,mV >= 10 MΩPt1000 -200°C 180°C 50°CNi100 -60°C 150°C 50°C LINEARITY (1)Ni1000 -60°C 50°C TC ± 0.2% f.s. RTD ± 0.1% f.s.VOLTAGEmV -100 mV +700 mV 2 mV LINE RESISTANCE INFLUENCE (1) Output/Power supply connections TC, mV <= 0.8 uV/Ohm RTD 3 wires 0.05%/Ω (50 Ω balanced max.)POTENTIOMETER 0Ω 200 Ω 10% RTD EXCITATION CURRENT(Nominal value) 200 Ω 500 Ω 10% Typical 0.350 mA 0.5 KΩ 2 KΩ 10% CJC COMP. ± 0.5 °C TEMPERATURE AND HUMIDITYRES. 2, 3 wires 300 Ω Operative temperature -20°C .. +70°CLow 0Ω 2000 Ω 10 Ω THERMAL DRIFT (1) Storage temperature -40°C .. +85°CHigh 0Ω 200 Ω FULL SCALE ± 0.01% /°C Humidity (not condensed) 0 .. 90% MaxOUTPUT TYPE Min Min Span CJC ± 0.01% /°C BURN-OUT VALUES EMC (for industrial environments) Max. value about 22.5 mADirect current 4 mA 20 mA 4 mA Min. value about 3.6 mA Immunity EN 61000-6-2Reverse current 20 mA 4 mA 4 mA Emission EN 61000-6-4 (1) referred to input Span (difference between max. and min. values) Mechanical dimensions (mm) DIN rail mounting (DIN RAIL Option) DIN B in-head mounting Fixing screws Coperchio Stirrup Fixing screw plastico di protezione80

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1060 Isolated two wire transmitter for RTD Input connections Programmable by Personal Computer mV RTD/RES 2 wires (*)INPUT TYPE INPUT MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME POT. (*) RTD/RES 3 wires (*) RTD/RES 4 wires MIN MAX 50°C 50°C RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 ms 50°C Low res. > ± 0.1% f.s. or ± 0.15ΩRTD (*) 2, 3, 4 wires 50°C High res. > ± 0.2% f.s. or ± 1ΩPt100 -200°C 850°C mV > ± 0.1% f.s. or ± 10 uV POWER SUPPLYPt1000 -200°C 200°C Power supply voltage 10..32 VdcNi100 -60°C 180°C Reverse polarity protection 60 Vdc maxNi1000 -60°C 150°C OUTPUT CALIBRATION ISOLATION VOLTAGE Current ± 7 uA Input-Power supply 2000 Vac, 50 Hz, 1 min.VOLTAGE INPUT IMPEDANCE LOAD CHARACTERISTIC - RLOAD Terminal 1 = GND INPUT; (*) connect terminals N° 3 and 2mV -100mV +700mV 2mV mV >= 10 MΩ Output/Power supply connections LINEARITY (1) RTD ± 0.1% f.s.POTENTIOMETER 0Ω 200 Ω 10% LINE RESISTANCE INFLUENCE (1)(Nominal value) 200 Ω 500 Ω 10% mV <= 0.8 uV/Ohm 0.5 KΩ 2 KΩ 10% RTD 3 wires 0.05%/Ω (50 Ω balanced max.) RTD 4 wires 0.005%/Ω (100 Ω balanced max.)RES. 2, 3,4 wires 300 Ω 10 ΩLow 0Ω 2000 Ω 200 Ω RTD EXCITATION CURRENTHigh 0Ω Typical 0.350 mA Max Min Span THERMAL DRIFT (1)OUTPUT TYPE Min 20 mA 4 mA FULL SCALE ± 0.01%/°C TEMPERATURE AND HUMIDITY Isolation structureDirect current 4 mA 4 mA 4 mA BURN-OUT VALUES Operative temperature -20°C .. +70°CReverse current 20 mA Max. value about 22.5 mA Storage temperature -40°C .. +85°C Power supply/output Min. value about 3.6 mA Humidity (not condensed) 0 .. 90% EMC (for industrial environments) Input, prog. Immunity EN 61000-6-2 Emission EN 61000-6-4 (1) referred to input Span (difference between max. and min. values) DAT1065 Isolated two wire universal transmitter Input connections Programmable by Personal Computer mV TC INPUT RTD/RES 2 wires (*) RTD/RES 3 wires (*) RTD/RES 4 wires POT. (*)INPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION(1) RESPONSE TIME 2mV RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 msTC (CJC int./ext.) 2mV Low res. > ± 0.1% f.s. or ± 0.15ΩJ -200°C 1200°C 2mV High res. > ± 0.2% f.s. or ± 1Ω POWER SUPPLYK -200°C 1370°C 2mV mV, TC > ± 0.1% f.s. or ± 10 uV Power supply voltage 10..32 VdcS -50°C 1760°C 2mV OUTPUT CALIBRATION Reverse polarity protection 60 Vdc maxR -50°C 1760°C 2mV Corrente ± 7 uAB 400°C 1820°C 2mV INPUT IMPEDANCE ISOLATION VOLTAGEE -200°C 1000°C 2mV TC,mV >= 10 MΩ Input-Power supply 2000 Vac, 50 Hz, 1 min.T -200°C 400°C 50°C LINEARITY (1)N -200°C 1300°C 50°C TC ± 0.2% f.s. LOAD CHARACTERISTIC - RLOAD 50°C RTD ± 0.1% f.s.RTD (*) 2, 3, 4 wires 50°CPt100 -200°C 850°CPt1000 -200°C 200°CNi100 -60°C 180°CNi1000 -60°C 150°CVOLTAGE 2 mV LINE RESISTANCE INFLUENCE (1) Terminal 1 = GND INPUT; (*) connect terminals N° 3 and 2mV -100 mV +700 mV TC, mV <= 0.8 uV/Ohm RTD 3 wires 0.05%/Ω (50 Ω balanced max.) Output/Power supply connections RTD 4 wires 0.005%/Ω (100 Ω balanced max.)POTENTIOMETER(Nominal value) 0Ω 200 Ω 10% RTD EXCITATION CURRENT 200 Ω 500 Ω Typical 0.350 mA 0.5 KΩ 50 KΩ 10% 300 Ω 10% 2000 ΩRES. 2, 3,4 wires 0Ω 10 Ω CJC COMP. ± 0.5 °CLow 200 ΩHigh 0Ω THERMAL DRIFT (1) TEMPERATURE AND HUMIDITY FULL SCALE ± 0.01% /°C Operative temperature -20°C .. +70°C Min Span CJC ± 0.01% /°C Storage temperature -40°C .. +85°C Isolations structureOUTPUT TYPE Min Max Humidity (not condensed) 0 .. 90% BURN-OUT VALUES Power supply/output Max. value about 22.5 mA Input, prog.Direct current 4 mA 20 mA 4 mA Min. value about 3.6 mA EMC (for industrial environments)Reverse current 20 mA 4 mA 4 mA Immunity EN 61000-6-2 (1) referred to input Span (difference between max. and min. values) Emission EN 61000-6-4 Mechanical dimensions (mm) DIN rail mounting (DIN RAIL Option) DIN B in-head mounting Fixing screws Springs Protection Stirrup Fixing screw plastic cap 81

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT1065 IS Isolated intrinsically safe two wire transmitter Input connection DAT 1065 IS/HT Programmable by Personal Computer mV TC POT. (*) INPUT RTD/RES 3 wires (*) RTD/RES 4 wires RTD/RES 2 wires (*)INPUT TYPE MIN MAX MIN SPAN INPUT CALIBRATION (1) RESPONSE TIME 2mV RTD > ± 0.1% f.s. or ±0.2°C (10÷ 90%) about 400 ms Terminal 1 = GND INPUT; (*)TC (CJC int./ext.) 2mV Low res. > ± 0.1% f.s. or ± 0.15ΩJ -200°C 1200°C 2mV High res. > ± 0.2% f.s. or ± 1Ω POWER SUPPLY Output/Power supply connectionsK -200°C 1370°C 2mV mV, TC > ± 0.1% f.s. or ± 10 uV Power supply voltage 11..30 VdcS -50°C 1760°C 2mV OUTPUT CALIBRATION Reverse polarity protection 60 Vdc max ExR -50°C 1760°C 2mV Current ± 7 uA barrierB 400°C 1820°C 2mV INPUT IMPEDANCE ISOLATION VOLTAGEE -200°C 1000°C 2mV TC,mV >= 10 MΩ Input-power supply 2000 Vac, 50 Hz, 1 min.T -200°C 400°C 50°C LINEARITY (1)N -200°C 1300°C 50°C TC ± 0.2% f.s. LOAD CHARACTERISTIC - RLOAD 50°C RTD ± 0.1% f.s.RTD (*) 2, 3, 4 wires 50°CPt100 -200°C 850°CPt1000 -200°C 200°CNi100 -60°C 180°CNi1000 -60°C 150°CVOLTAGE 2 mV LINE RESISTANCE INFLUENCE (1)mV -100 mV +700 mV TC, mV <= 0.8 uV/Ohm RTD 3 wires 0.05%/Ω (50 Ω balanced max.)POTENTIOMETER RTD 4 wires 0.005%/Ω (100 Ω balanced max.)(Nominal value) 0 Ω 200 Ω 10% RTD EXCITATION CURRENT 200 Ω 500 Ω 10% Typical 0.350 mA 0.5 KΩ 2 KΩ 10%RES. 2, 3,4 wires 0Ω 300 Ω 10 Ω CJC COMP. ± 0.5 °C TEMPERATURE AND HUMIDITYBasso 2000 Ω 200 Ω THERMAL DRIFT (1) Operative temperature -20°C .. +70°CAlto 0Ω Max FULL SCALE ± 0.01% /°C -20°C..+85°C (’HT’ vers.) Isolation structureOUTPUT TYPE Min Min Span CJC ± 0.01% /°CDirect current 4 mA 20 mA 4 mA BURN-OUT VALUES Storage temperature -40°C .. +85°C Input, program. side Output/Power supply sideReverse current 20 mA 4 mA 4 mA Max. value about 22.5 mA Humidity (not condensed) 0 .. 90% Min. value about 3.6 mA EMC (for industrial environments) Immunity EN 61000-6-2 (1) referred to input Span (difference between max. and min. values) Emission EN 61000-6-4 Mechanical dimensions (mm) DIN B in-head mounting DIN rail mounting (DIN RAIL Option) Fixing screws Springs Protection Stirrup Fixing screw plastic cap82

“DAT400 SERIES”: The DAT400 series has been developedPOWER SUPPLIERS as integration of the signal converters and transmitters. The series is composed of: - Switching power supplier for AC line input, 24 Vdc @ 1 A output (DAT420) - Power supplier for AC line input with two not regulated outputs (DAT411) - Switching power supplier for AC line input with two regulated outputs (DAT411R) POWER SUPPLIERS 85

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT420 Universal Switching Power Supply Unit Input connections with 24 Vcc @ 1A outputINPUT 100 ÷ 250 VcaVoltage 0.30 ÷ 0.12 A max.Current 48 ÷ 65 HzFrequency 7 A max.Start-Up Current Spike 0.60 ÷ 0.65Power FactorOUTPUT 24 Vcc ± 10% trimmer regulation Output connectionsVoltage 1ANominal Current 1.8 A PositiveCurrent Limitation 30 mVpp, 80 KHz max.Ripple with nominal lo 50 mV with (0-1) A stepLoad variation response 7 msStart-Up rise time 10 ms with nominal Vi and IoShut-down maintenance 82% with nominal Vi and loEfficiency NegativeENVIRONMENTAL DATAInput/Output Isolation 4000 Vca / 60 sec.Input/PE IsolationElectric Safety 1500 Vca / 60 sec. EN 60950 Isolation structureElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating Temperature 24 VccStorage Temperature -10÷50°C 100÷250 Vac Output InputHumidity (not condensed) -20÷60°C 0÷85% DAT411 Double output Input connections power supply unitINPUT 24 Vca ± 10% @ 50-60 Hz Output 1 connectionsInput voltage 120 Vca ± 10% @ 50-60 HzOUTPUTS 230 Vca ± 10% @ 50-60 Hz Output 2 connectionsOutput 1 (Out 1)Output 2 (Out 2) 20 Vcc @ 25 mA not reguleted for Rload= 250 ohm Note: terminals A and B not connected (NC)Load resistance (Rload) 20 Vcc @ 25 mA not reguleted for Rload= 250 ohm see section “Load characteristic” Load characteristicENVIRONMENTAL DATA Output voltageSafety EN 61010-1 1 out with Rload= 0 ohmElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4 2 out with Rload= 250 ohmOperating Temperature -20÷60°C 3 out with Rload= 470 ohmStorage Temperature Output currentHumidity (not condensed) -40÷85°C 0÷90% Mechanical dimensions (mm)86

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT411R Double regulated output Input connections power supply unitINPUT 24 Vca ± 10% @ 50-60 Hz Output 1 connectionsInput voltage 120 Vca ± 10% @ 50-60 HzOUTPUTS 230 Vca ± 10% @ 50-60 Hz ConverterOutput 1 (Out 1)Output 2 (Out 2) 20 Vcc @ 30 mA regulated Output 2 connectionsLoad resistance (Rload) 20 Vcc @ 30 mA regulated see section “Load characteristic” Converter Note: terminals A and B not connected (NC)ENVIRONMENTAL DATASafety EN 61010-1 Load characteristicElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operating temperature -20÷60°C Output voltageStorage temperatureHumidity (not condensed) -40÷85°C Output current 0÷90% Mechanical dimensions (mm) 87

“DAT700”, The series of digital indicators DIGITAL INDICATORS FOR PANEL MOUNTING“DAT8000 SERIES”: is composed of instruments dedicatedDIGITAL to the measure of temperature andINDICATORS FOR process control signals. The DAT700 series is available in a housing of size 36* 72 mm and is composed of the following devices: - Digital indicator with 3.5 digit LED display (DAT701) - Digital indicator with 3.5 digit LCD display (DAT702) - Self-powered digital indicator with 3.5 digit LCD display (DAT733) - Digital Thermometers for Pt100 or Thermocouple sensors with 3.5 digit LCD or LED displays (DAT734, DAT735) The DAT8000 series is composed of a single programmable self-powered current loop digital indicator with 4 digit LED display available in a housing of size 48* 96 mm (DAT8050) 89

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT701 3.5 digit LED Input Connections (**) digital indicator Volt - Basic full-scale Volt - Attenuated full-scaleINPUT mA - Basic full-scale mA - Attenuated full-scaleConfigurationSignal type Bipolar, true differential (**) Note: if the input signal is isolated from the power supply Voltage: from 200 mV up to 2 V (Version A), basic full scale 200 mV the terminal 3 (IN LO) must be connected to the terminal 4 (COM).Input impedanceMaximum input signal from 2 V up to 200 V (Version B), basic full scale 2 V Complementary function connectionsCommon mode voltage Corrent: from 200 µA up to 2 mA (Version A), basic full scale 200 µACommon mode rejection ratio Function Hold Function TestNormal mode rejection ratio from 2 mA up to 200 mA (Version B),basic full scale 2 mADecimal point programming Voltage: basic full scale: 10 MΩVISUALIZATIONScale of visualization attenuated scale: 1 MΩOut of range visualization Current: from 1Ω up to 1 KΩType of visualization Full scale 2.5Digit height ± 2 V referred to the power supply ground 86 dB 50 dB @ 50 Hz From front side, on three decades 2000 points (from 0 up 1999 or from -1999 up to 0) High= 1. Low= -1 3.5 digit standard LED display (version S) 3.5 digit high efficiency LED display(version H) 0.52”PERFORMANCES Power supply connectionsReading accuracy ± 0.1% of f.s.Thermal driftReading rate 0.005% of f.s./°CPower supply voltage 3 read/secondCurrent consumption 5 Vcc ± 5% Version S: 90 mA Version H: 180 mAElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operative temperature -10÷60 °CStorage temperatureRelative Humidity (not condensing) -40÷85 °C 0÷90% DAT702 3.5 digit LCD Input connections (**) digital indicator Volt - Basic full-scale Volt - Attenuated full-scaleINPUT mA - Basic full-scale mA - Attenuated full-scaleSignal type Voltage: from ± 200 mV up to ± 2 V (Version A), basic full scale: 200 mV (**) Note: if the input signal is isolated from the power supplyInput impedance from ± 2 V up to ± 200 V (Version B), basic full scale: 2 V the terminal 3 (IN LO) must be connected to the terminal 4 (COM).Maximum input signalCommon mode voltage Current: from ± 200 µA up to ± 2 mA (Version A) basic full scale: 200 µA Complementary function connectionsCommon mode rejection ratio from 2 ± mA up to ± 200 mA (Version B) basic full scale: 2 mANormal mode rejection ratio Function Hold Function TestDecimal point programming Voltage: basic full scale: 10 MΩVISUALIZATION attenuated full scale: 1 MΩType of visualizationDigit height Current: from 1Ω up to 1 KΩ full scale 2.5 ± 2 V refered to supply ground 86 dB 50 dB @ 50 Hz From rear side, on three decades Static polarised Liquid Cristal Display for wide angle of visualization 0.35”PERFORMANCESReading accuracy ± 0,1% of f.s.Thermal drift Power supply connectionsReading rate 0,005% of f.s./°CPower supply voltage 3 read/second Version 5: 5 Vcc ± 5%Current consumption Version 9: 9 Vcc ± 10% Version 5: 3 mA Version 9: 0.5 mAElectromagnetic Compatibility (EMC) (for industrial environments) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operative temperature -10÷60 °CStorage temperatureRelative Humidity (not condensing) -40÷85 °C 0÷90% Mechanical dimensions (mm)90

TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) DAT733 3.5 digit LCD Input connections digital indicatorINPUT 4÷20 mA from current loop Complementary function connectionsSignal type 2.5 VVoltage drop 50 mA Function HoldMaximum input signal By dip switch and regulation by potentiometersVisualization settings From -1999 up to 1999Zero value visualization Scale 1 from 100 up to 700 pointsScales of visualization Scale 2 from 700 up to 1400 pointsDecimal point setting Scale 3 from 1400 up to 2000 pointsOut of scale indication From rear side, by dip-switch, on three decades High: 1 (on left side); Low: -1 (on left side)VISUALIZATIONType of visualization 1 -1Digit height Static polarised Liquid Cristal Display for wide angle of visualization 0.35”PERFORMANCESReading accuracy ± 0.1% of f.s.Thermal driftReading rate 0.005% of f.s./°CPower supply voltage 3 read/second Self-powered from the input signalElectromagnetic Compatibility (EMC) (Per ambienti industriali) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operative temperature -10÷60 °CStorage temperatureRelative Humidity (not condensing) -40÷80 °C 0÷90% DAT734 3.5 digit LCD or LED display Power supply connections digit thermometer for Pt100INPUT 2 or 3 wires Pt100 sensorType of signal -50 ÷ 200 °CInput range 0 ÷ 600 °COut of scale visualization High: 1 (On the left side); Low: -1 (On the left side) 1 -1 Input connections Pt100 wires Pt100 wiresVISUALIZATION Static polarised Liquid Crystal Display for wide angle of visualizationType of visualization (LCD-version C) 0.35”Digit height High efficiency LED display or standard LED displayType of visualization (LED-version D) 0.52”Digit heightPERFORMANCESReading accuracy ± 0.25% of f.s.Thermal driftResponse time 0.02% of f.s./°C Complementary function connectionsPower supply voltage 800 ms Hold FunctionCurrent consumption 5 Vdc ± 5% Version D: 180 mA (high efficiency), 90 mA (standard) Version C: 10 mAElectromagnetic Compatibility (EMC) (Per ambienti industriali) Immunity: EN 61000-6-2; Emission: EN 61000-6-4Operative temperature -10÷60 °CStorage temperatureRelative humidity (not condensed) -40÷80 °C 0÷90% Mechanical dimensions (mm) 91