Our state-of-the art facility consists of a control room and four simulation rooms designed to accommodate a simulation hospital or emergency home setting. Each simulation room provides audio-visual professional recording capabilities to assist instructors in debriefing students in the classroom. Our center features: Simulations can reduce medical errors, improve clinical decision- Sim Man 3G Sim Mom making skills, and enhance student Sim Newborn Sim Junior engagement. Scenarios can be created to expose students and Health Science Center 52 University Boulevard medical professionals to real-world Roswell, NM 88202 conditions. Phone: 575-624-7435 Fax: 575-624-7083 Email: [email protected] This workforce product was funded by a grant awarded by the U.S. Department of Labor’s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The U.S. Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any information on linked sites and including, but not limited to, accura- cy of the information or its completeness, timeliness, usefulness, adequacy, continued availability, or ownership. The New Mexico SUN PATH TAACCCT project provides equal opportunities (EO) to all applicants without regard to race, color, religion, gender, sexual orien- tation, gender identity or expression, national origin, age, disability, genetic information, marital status, amnesty, or status as a covered veteran in accordance with applicable federal, state and local regulations.
ENMU-Roswell Regional Medical Simulation Center SimMan 3-G, a wireless high-fidelity patient simulator. SimMan is a computer controlled, full body adult manikin with realistic anatomical landmarks that can simulate a wide variety of life-like physical findings. Circulation Features: • BP measured manually by auscultation of Korotkoff sounds • Carotid, femoral, brachial, radial, dorsalis pedis, popliteal and posterior tibi- alis pulses synchronized with ECG • Pulse strength variable with BP • Pulse Palpation is detected & logged CPR: • Compliant with /CPR Guidelines • CPR compressions generate palpable pulses, blood pressure wave form, and ECG artifacts • Realistic compression depth and resistance Cardiac Features: • Detection of depth, release and fre- • Extensive ECG library quency of compressions • Heart sounds - four anterior locations • Real time feedback on quality of CPR • ECG rhythm monitoring (4 wire) • 12 lead ECG display • Defibrillation and cardioversion • Pacing Airway Complications: • Detection of proper head position • Can’t intubate/Can ventilate Breathing Features: • Can’t intubate/Can’t ventilate • Simulated spontaneous breathing Breathing Complications: • Tongue edema • Bilateral and unilateral chest rise • Cyanosis • Pharyngeal swelling and fall • Laryngospasm • Needle thoracentesis - bi-lateral • CO2 exhalation • Decreased cervical range of • Unilateral & Bilateral chest • Normal and abnormal breath movement motion sounds • Trismus • Unilateral, Bilateral & lobar - 5 anterior auscultation sites breath sounds - 6 posterior auscultation sites • Chest tube insertion - bilateral • Oxygen saturation and waveform
Other Features: • Seizure/Fascicullation • Bleeding - Simulation of bleeding at multiple sites - Arterial and venous - Vital signs automatically respond to blood loss & therapy - Works with various wound modules & moulage kits Eyes: • Urine output (variable) • Blinking - slow, normal, fast and winks • Foley catheterization • Open, closed and partially open • Secretions • Pupillary accommodation: - Eyes, Ears, Nose, Mouth - synchrony/asynchrony - Blood, Mucous, CSF, etc. - normal and sluggish speed of response • Diaphoresis • Bowel Sounds - four quadrants Pharmacology: • Patient Voice • Automatic Drug Recognition - Pre-recorded sounds System identifies drug & dose - Custom sounds • Extensive drug formulary - Instructor can simulate patient’s voice wirelessly • Automatic or programmable • Instructor Communication physiological responses - Multiple instructors communicate using integrated voice over IP Multiple Airway Skills/Features: Controllable open/closed airway; automatically or manually controlled • Suctioning (Oral & Nasopharyngeal) • Head tilt/Chin lift • Fiberoptic intubation • Jaw thrust w/articulated jaw • Stomach distention • Bag-mask ventilation • Orotracheal intubation • Nasotracheal intubation • Endotracheal tube intubation • Combitube, LMA, and other airway placement • Retrograde intubation • Transtracheal jet ventilation • Needle cricothyrotomy • Surgical cricothyrotomy Vascular Access: • Variable lung compliance • Variable airway resistance • IV access (right arm) - 4 settings - 4 settings • Intraosseous access (tibia) • Right main stem intubation • Automatic Drug Recognition System • Connectivity with third party respiratory simulations This workforce product was funded by a grant awarded by the U.S. Department of Labor’s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The U.S. Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any in- formation on linked sites and including, but not limited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, continued availability, or ownership. The New Mexico SUN PATH TAACCCT project provides equal opportunities (EO) to all applicants without regard to race, color, religion,
ENMU-Roswell Regional Medical Simulation Center SimMom is an advanced full body birthing simulator with accu- rate anatomy and functionality to facilitate multi-professional obstetric training of birth management, with both manual and automatic de- livery modes. Deliveries & drills: Normal delivery Pelvic Components: Breech presentation Atonic uterus modules (for PPH, uterine Assisted deliveries inversion and retained placenta) Forceps Fluids (e.g. blood, stained amniotic fluid Vacuum and urine) Shoulder dystocia Urine catheterization/instillation Cord prolapse Eclampsia & pre-eclampsia Maternal collapse Movements: Post Partum Hemorrhage Sepsis Seizure Uterine inversion Able to position on all fours: Ruptured uterus Realistic rotation of the shoulder and hip joints Legs bend at the knees Arms bend at the elbow Breathing Features: Other positions: Simulated spontaneous breathing Supine Variable respiratory rates Semi-recumbent Bilateral and unilateral chest rise and fall Left lateral Normal and abnormal breath sounds Legs in stirrups 4 anterior auscultation sites McRoberts position Bilateral midaxillary sites
Circulation Features: BP measured manually by auscultation of Korotkoff sounds Bilateral carotid and brachial pulse, radial (right side only pulses synchronized with ECG Pulse strength variable with BP Pulse palpation is detected and logged Cardiac Features: Extensive ECG library Heart sounds synchronized with ECG ECG rhythm monitoring 12 lead ECG display Defibrillation and cardioversion Pacing Vascular Access: Pre-ported IV access (both arms) Subcutaneous and intramuscular injection sites Airway Features: Obstructed airway Tongue edema Right lung, left lung and both lung blockage Head tilt/Chin lift Jaw thrust Suctioning techniques (oral and nasopharyngeal) Bag-Valve-Mask ventilation Oropharyngeal and nasopharyngeal intubation Combitube, LMA and other airway device placement Endotracheal intubation (ET) Retrograde intubation Other Features: Nasal and oral fiber optic intubation Bowel sounds and fetal heart rate (not at the same time) Trans-tracheal jet ventilation Interchangeable pupils (normal, blown and constricted) Right mainstem intubation Patient Voice Surgical and needle cricothyrotomy Pre-recorded sounds Custom sounds Instructor can simulate patient’s voice wirelessly This workforce product was funded by a grant awarded by the U.S. Department of Labor’s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The U.S. Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any infor- mation on linked sites and including, but not limited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, contin- ued availability, or ownership. The New Mexico SUN PATH TAACCCT project provides equal opportunities (EO) to all applicants without regard to race, color, religion, gen-
ENMU-Roswell Regional Medical Simulation Center SIM Junior SimJunior represents a 6 year old boy that simulates a wide range of conditions from a healthy, talking child to an unresponsive, critical patient with no vital signs. SimJunior allows learners to focus on a broad range of pediatric skills in order to gain exposure and practical experience of life-threatening pediatric problems. Airway The SimJunior airway is anatomically modeled as far as the trachea. Realistic airway with landmarks Vascular Access Oral and nasal intubation LMA or ET insertion IV access (right arm and hand) Tongue edema Intraosseous access (right tibia) NG tube Cricoid cartilage Head tilt and jaw thrust (no sensor)
Chest Compressions Compliant with 2010 AHA and ERC Guidelines CPR compressions generate palpable pulses, blood pressure waveform, and ECG artifacts Detection and logging of a series of compressions in the data log Sounds Heart Lung Bowel Patient voice Pre-recorded sounds Wireless microphone Cardiac Defibrillation and cardioversion Pacing Breathing Extensive ECG library Simulated spontaneous breathing Multiple heart sounds synchronized with ECG Observable chest rise ECG rhythm monitoring (3 leads) Variable respiratory rates 12 lead ECG display (Optional Patient Monitor) Multiple upper airway sounds synchronized with breathing Detect and quantify the volume of mechanical ventilations (including no ventilations) Bag Valve Mask capable Normal and abnormal breath sounds Oxygen saturation and waveform (Optional Patient Monitor) Breathing complications Bilateral chest movement with spontaneous breathing Unilateral chest rise with right mainstem intubation Unilateral and bilateral breath sounds Left and right lungs can be either closed or opened to allow ventilations Circulation Blood pressure measured manually by auscultation of Korotkoff sounds Bilateral carotid and unilateral brachial and radial (left side) pulses synchronized with ECG Pulse strength variable with BP Pulse palpation is detected and logged This workforce product was funded by a grant awarded by the U.S. Department of Labor’s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The U.S. Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any information on linked sites and including, but not limited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, continued availability, or ownership. The New Mexico SUN PATH TAACCCT project provides equal opportunities (EO) to all applicants without regard to race, color, religion, gender, sexual orientation, gender identity or expression, national origin, age, disability, genetic information, marital status, amnesty, or status as a covered veteran in accordance with applicable federal, state and local regulations.
SimNewB has been designed to be easily integrated into all neonatal clinical training curricula. An innovative user interface and scenario design allows instructors to control the simulator’s responses. Airway Features: Anatomically Accurate, Realistic Airway ET Tube Insertion LMA Insertion Sellick Manoeuvre Positive-Pressure Ventilation Right Mainstem Intubation Suctioning Variable Lung Resistance Gastric Tube Insertion Breathing Features: Spontaneous breathing, with variable rate Bilateral and unilateral chest rise and fall with mechanical ventilation CO2 exhalation Normal and abnormal breath sounds Oxygen saturation Breathing Complications: Pneumothorax Unilateral chest movement with mechanical ventilation Unilateral breath sounds Unilateral needle thoracentesis, mid-axillary
Cardiac Features: Extensive ECG Library with rates from 10 - 300 bpm ECG monitoring via 3-lead monitor Circulation Features: Heart Sounds Umbilical and Brachial Pulse Blood Pressure measured manually by auscultation of Korotkoff sounds Vascular Access: Patent, cuttable umbilicus with venous and arterial access for bolus or infusion Simulated blood flashback upon cannulation Sounds Vocal: Grunt breathing, crying, hiccups and others Lung: Normal, stridor, pneumonia and others Heart: Normal, diastolic murmur, systolic murmur and others Other Features: Interchangeable pupils with normal, blown and constricted pupils Movement in all four limbs: limp, tone, spontaneous motion and seizure This workforce product was funded by a grant awarded by the U.S. Department of Labor’s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The U.S. Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any infor- mation on linked sites and including, but not limited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, contin- ued availability, or ownership. The New Mexico SUN PATH TAACCCT project provides equal opportunities (EO) to all applicants without regard to race, color, religion, gen-