Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore ACSR WEASEL

ACSR WEASEL

Published by sanjayconductor, 2015-09-02 02:49:53

Description: We produce ACSR dog and wolf conductor that cater to all needs of our customers requiring solutions in the field of overhead power distributions and transmission.

Keywords: ACSR PANTHER,ACSR WEASEL

Search

Read the Text Version

SANJAY CONDUCTORS & CABLES An ISO : 9001 : 2008 Certified Company by United Kingdom Accredation Service. UK (UKAS) OUR PRODUCTS: We produce products that cater to all needs of our customers requiring solutions in the field of overhead power distributions and transmissionACSR - ALUMINIUM CONDUCTORS STEEL REINFORCED AAC - ALL ALUMINIUM CONDUCTORS AAAC - ALL ALUMINIUM ALLOY CONDUCTORS AACSR CONDUCTORS ACAR CONDUCTORS INSULATED CONDUCTORS STEEL WIRE & STAY WIRE ALL TYPES OF DISTRIBUTION & TRANSMITIN LINE MATERIAL SILICONE, POLYMER, PORCELAIN INSULATOR UP TO 132 KV CABLE JOITING KIT. VCB PANEL. LIGHTING ARRESTER. INDOOR & OUTDOOR TERMINATIONS UP TO 66 KV

 HT/ LT UNDERGROUND CABLES ABC CABLES HT / LT SINGLE CORE CABLES ALL TYPES OF CABLES STAY, DISC, POST, COMPOSITE , PIN INSULATORS TRANSFORMERS - DISTRIBUTION & POWER - Rating up to 4000 kvaPRODUCT OPTIONS :ACSR conductors consist of a solid or stranded steel core surrounded bystrands of aluminum (E.C. GRADE). ACSR conductors are available in a widerange of steel, containing carbon from 0.5% to 0.85 %. The higher strengthACSR conductors are used for river crossings, overhead ground wires,installations involving extra long spans etc. Against any given resistance ofconductor, ACSR may be manufactured within a wide range of tensile strengthas per the requirement.Key Benefits :The principal advantage of these conductors are high tensile strength so thatthey are used for longer spans with less supports. Due to the greater diameter ofACSR conductors a much higher corona limit can be obtained causing bigadvantages on high as well as extra high voltage overhead lines.Due to the greater diameter of ACSR Conductor a much higher corona limitcan be obtained causing big advantages on high as well as extra high voltageOverhead lines.The principal advantage of these conductors are high tensilestrength so that they are used for longer spans with less supports.Some of the important sizes are as under : ACSR IS -398 II :1976 & IS -398 V :1992

CODE Cond. Stranding& Wire Dia Calculated sectional Area Approx WeightNAME Area overall kg/km mm2 Alum. Steel Alum. ACSR in mm in mm Sq.mm Sq.mm Dia mm ACSR Mole 10 6/1.50 1/1.50 10.60 12.37 4.50 43 SC 18 6/1.95 1/1.95 18.10 21.12 5.88 73 20 6/2.11 1/2.11 20.98 24.48 6.33 85Squirrel 30 6/2.59 1/2.59 31.61 36.88 7.77 128Weasel 50 6/3.35 1/3.35 52.88 61.70 10.05 214 Rabbit 80 6/4.09 1/4.09 78.83 91.97 12.27 319Raccoon 100 6/4.72 7/1.57 105.00 118.50 14.15 394 130 6/5.28 7/1.76 129.7 150.1 15.85 493 Dog 150 30/2.59 7/2.59 158.10 194.90 18.13 726Leopard 200 30/3.00 7/3.00 212.10 261.50 21.00 974 400 42/3.50 7/1.96 404.10 425.20 26.88 1281 Wolf 420 54/3.18 7/3.18 428.90 484.50 28.62 1621PantherKundah 520 54/3.53 7/3.53 528.50 597.00 31.77 2004 Zebra MooseCONTACT US FOR YOUR ANY ITEM FOR DISTRIBUTION OR TRANSMITION LINE For more Details Contact at: G. T. ROAD, NEAR MARKFED, KHANNA - 141401 PUNJAB, INDIA. Phone :91 1628 225617 Mobile :91 98156 25617 :91 98721 99900 [email protected] | http://sanjayconductors.com/our_products_-_acsr_conductors


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook