LIGHTING REPORT For, Hotel Centre point, Bar Area.
LIGHTING REPORT Date of Inspection : 2-Feb-2016 Area Of Inspection : Bar Expected Lux Level : 70 - 110 Lux Current Lux Level : 100 Lux Lighting Method: Direct lighting Light Source : Strip Lights Beam Angle : 120 Degree Diffuser : Acrylic
LIGHTING REPORT The objective of the Inspection was to check the lux level, and provide solution to decrease the brightness without making any changes in the existing interior for the Bar. Proposed Solutions : - Use Dimmable Driver for the existing LED Strip Lights : The brightness of the Strip lights can be reduced using dimmable driver they are controlled using remote - Replace Existing 14W by 4.4W 3528 Strip Lights : The 3528 Strip lights have less lumens output compared to 14W Strip lights and thus would decrease the overall Lux levels. - Use Thicker Acrylic : The Lux levels can be decreased by using thicker diffusers for the light source.