Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore SOT ÜRÜN KATALOĞU ENG 2022

SOT ÜRÜN KATALOĞU ENG 2022

Published by Asim Atici, 2023-06-12 08:10:54

Description: SOT ÜRÜN KATALOĞU ENG 2022

Search

Read the Text Version

Smoke Exhaust Fans SOA – Wall Mounted Axial Fan SOA 900-5-35 SOA 900-5-40 Pa Pa Pa Pa 700 5000 10000 15000 20000 25000 30000 35000 40000 45000 800 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 Pa Pa Pa Pa600 m³/h 700 m³/h 500 600 400 500 300 400 200 300 100 200 100 0 0 0 0 800 700 SOA 1000-5-40 SOA 900-8-40 600 500 10000 20000 30000 40000 50000 60000 1000 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 400 m³/h 900 m³/h 300 800 200 700 100 600 500 0 400 0 300 200 1200 100 0 0 SOA 1000-8-40 SOA 1000-8-45 1200 1000 1000 800 800 600 600 400 400 200 200 0 10000 20000 30000 40000 50000 60000 70000 0 10000 20000 30000 40000 50000 60000 70000 80000 0 m³/h 0 m³/h 1400 SOA 1120-8-40 1600 SOA 1120-8-45 1400 1200 1200 1000 1000 800 800 600 400 600 200 400 0 0 200 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 20000 40000 60000 80000 100000 120000 0 m³/h m³/h www.sothvac.com 101

SRF – Fan Filter Unit Industrial Fans Description : SRFs are delivered with a G4 dust filter and an active carbon filter. The filters can be changed optionally at production and a third filter also can be added. MOTOR INSULATION CLASS F CLASS MOTOR PROTECTION CLASS IP 44 MOTOR EFFICIENCY CLASS - MOTOR ENCLOSURE TYPE BODY MATERIAL EXTERNAL ROTOR MOTOR BODY COATING GALVANIZED SHEET METAL IMPELLER MATERIAL DUTY CYCLE NONE WORKING TEMPERATURE ALUMINIUM STANDARDS IEC Duty Cycle-S1 -20 - +50 °C IEC-60335-2-80, ISO 1940-1 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE SOUND PRESSURE (V) (Hz) (W) (RPM) (m3/h) dB(A) 3m SRF 5 230 50 665 73 SRF 10 85 2722 SRF 20 230 50 950 73 SRF 30 122 2670 SRF 40 230 50 1665 75 210 2580 230 50 3230 78 380 1420 230 50 4655 80 690 1365 Values are for 0 Pa MODEL A (mm) B (mm) C (mm) 300 300 500 SRF 5 350 350 500 SRF 10 400 400 500 SRF 20 450 450 600 SRF 30 500 500 600 SRF 40 www.sothvac.com 102

Industrial Fans SRF – Fan Filter Unit SRF Performance Curves SRF 5 SRF 10 Pa Pa Pa 350 600 Pa Pa300 250 500 200 150 400 100 300 50 0 200 0 100 800 700 100 200 300 400 500 600 700 0 00 2003 00 4005 00 6007 00 8009 00 1000 600 m³/h 01 m³/h 500 400 SRF 20 400 SRF 30 300 350 200 00 4006 00 800 1000 1200 1400 1600 1800 300 500 1000 1500 2000 2500 3000 3500 100 250 200 0 150 02 100 50 0 0 m³/h m³/h SRF 40 500 00 1000 1500 2000 2500 3000 3500 4000 4500 5000 450 400 350 300 250 200 150 100 50 0 05 m³/h www.sothvac.com 103

SHFF – Fan Filter Unit With HEPA Filter Industrial Fans Description : SHFF has a G4, carbon and H13 HEPA filter. This allows it to keep the dust, odor and small particles out of the air supplied. MOTOR INSULATION CLASS F CLASS MOTOR PROTECTION CLASS IP 44 MOTOR EFFICIENCY CLASS - MOTOR ENCLOSURE TYPE MOTOR BRAND EXTERNAL ROTOR MOTOR BODY MATERIAL SOT BODY COATING IMPELLER MATERIAL GALVANIZED SHEET METAL DUTY CYCLE NONE WORKING TEMPERATURE STANDARDS ALUMINIUM IEC Duty Cycle-S1 -20 - +50 °C IEC-60335-2-80, ISO 1940-1 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE SOUND PRESSURE (V) (Hz) (W) (RPM) (m3/h) dB(A) 3m SHFF 10 SHFF 20 230 50 104 2675 800 73 SHFF 30 230 50 130 2685 1500 75 230 50 180 2615 2000 78 Values are for 0 Pa MODEL A (mm) B (mm) C (mm) SHFF 10 500 350 780 SHFF 20 500 350 800 SHFF30 600 400 920 104 www.sothvac.com

Commercial Fans SRF – Fan Filter Unit With HEPA Filter www.sothvac.com INDUSTRIAL FANS 105

SMX – Mixed Flow Fans Industrial Fans Description : SMX fans are used in areas such as warehouses where the shelves are very dense and the air does not move. It helps to provide a balanced temperature istribution by mixing the air in the environment and bringing the hot air above down. MOTOR INSULATION CLASS F CLASS MOTOR PROTECTION CLASS IP 55 MOTOR EFFICIENCY CLASS IE3 MOTOR ENCLOSURE TYPE TEFC MOTOR BRAND VOLT BODY MATERIAL BODY COATING MATERIAL GALVANIZED SHEET METAL IMPELLER MATERIAL ELEKTRO-STATIC POWDER COATING DUTY CYCLE WORKING TEMPERATURE PLASTIC STANDARDS IEC Duty Cycle-S1 -20 - +50 °C IEC-60335-2-80, ISO 194 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE SOUND PRESSURE SMX 800-5-30 (V) (Hz) (W) (RPM) (m3/h) dB(A) 3m 380 50 0,25 750 13000 66 Values are for 0 Pa MODEL A (mm) B (mm) C (mm) D (mm) E (mm) Number Of Chain SMX 800-5-30 800 900 200 500 1000 4 106 www.sothvac.com

Industrial Fans SIR – Low Pressure Centrifugal Fan Description : Pressure: 500 - 1200 pa. Airflow: 3.000 - 12.500 m3/h. Forward curved impeller. Direct coupling. Minimum engine power, max. capacity. Used areas: Aspiration of clean or slightly dusty or clean air. Aspiration of exhaust fumes. MOTOR INSULATION CLASS F CLASS MOTOR PROTECTION CLASS IP 55 MOTOR EFFICIENCY CLASS IE2-IE3 MOTOR ENCLOSURE TYPE BODY MATERIAL AC-TEFC BODY COATING MATERIAL DKP SHEET METAL IMPELLER TYPE ELEKTRO-STATIC POWDER COATING IMPELLER MATERIAL FORWARD CURVED DUTY CYCLE DKP SHEET METAL WORKING TEMPERATURE IEC Duty Cycle-S1 STANDARDS -20 - +50 °C IEC-60335-2-80, ISO 1940-1 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE (V) (Hz) (W) (RPM) (m3/h) SIR-75 380 1410 3000 SIR-110 380 1 0,75 1430 4000 SIR-150 380 1430 5000 SIR-220 1,5 1,1 SIR-300 380 1435 6500 SIR-400 2 1,5 SIR-550 380 1435 7500 SIR-750 380 3 2,2 1455 8500 380 1465 10500 380 43 1465 12500 5,5 4 7,5 5,5 10 7,5 Values are for 0 Pa MODEL A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) SIR-75 520 574 619 200 255 185 SIR-110 566 594 725 246 270 205 SIR-150 619 634 688 260 290 225 SIR-220 660 674 912 300 315 240 SIR-300 681 716 907 300 370 250 SIR-400 755 756 891 320 400 270 SIR-550 794 855 1.017 350 460 330 SIR-750 876 905 1.041 350 545 380 www.sothvac.com 107

SFC – Belt Drive Cabinet Fan Industrial Fans Description : SFC Ventilation Unit can be used in the range of 500 m³/h to 100.000 m³/h air flow capacity, G4, G2, F7 etc. applicable as filter and production is made in different types and sizes if desired. * Housing structure is aluminum carcass and the corners are produced as plastic and aluminum components. * Panel thicknesses are produced as standard 25mm or optional 50mm rockwool insulated double skin, Electrostatic Powder Painted and Leak-proof Gasket. * Double Inlet Radial Fans with Belt Driven Assemblies are Used inside. * Easy installation is possible with the compact design. * It is used for supply, exhaust or pressurization for the ventilation. Factory, Hospital, Office, Laboratory, Shopping Center (shopping malls), Cafe, Restaurants, Parking lots etc. It is suitable for use in all structures which has air duct system. MOTOR PROTECTION CLASS IP 55 MOTOR INSULATION CLASS F CLASS MOTOR EFFICIENCY CLASS IE2-IE3 MOTOR ENCLOSURE TYPE MOTOR BRAND TEFC BODY MATERIAL GAMAK - VOLT -WAT BODY COATING GALVANIZED SHEET METAL IMPELLER TYPE OPTIONAL POWDER COATING IMPELLER METERIAL FORWARD CURVED DUTY CYCLE GALVANIZED SHEET METAL WORKING AMBIENT TEMP DIRECTIVE IEC Duty Cycle-S1 -20 - +50 °C IEC-60335-2-80, ISO 1940-1 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE SOUND PRESSURE WEIGHT (V) (Hz) (W) (RPM) (m3/h) dB(A) 3m (KG) SFC 7/7 A 50 2250 65 69 SFC 7/7 B 230 or 380 50 0,75 1400 2750 65 72 SFC 9/9 A 230 or 380 50 4250 69 80 SFC 9/9 B 230 or 380 50 1,1 1400 5000 69 82 SFC 10/10 A 230 or 380 50 6000 70 89 SFC 10/10 B 230 or 380 50 1,1 1400 6800 70 94 SFC 12/12 A 230 or 380 50 8200 71 120 SFC 12/12 B 230 or 380 50 1,5 1400 9800 71 123 SFC 15/15 S 230 or 380 50 11500 70 138 SFC 15/15 B 230 or 380 50 1,5 1400 12500 70 144 SFC 18/18 A 50 16000 65 186 SFC 18/18 B 380 50 2,2 1400 20000 65 193 380 380 2,2 1400 3 1400 3 1400 4 1400 5,5 1400 7,5 1400 Values are for 0 Pa W H CxD B B A 104 L L1 MODEL L1 (mm) L (mm) W (mm) H (mm) A (mm) B (mm) C (mm) D (mm) SFC 7/7 1050 850 600 600 235 205 220 520 SFC 9/9 1150 950 650 650 295 260 245 570 SFC 10/10 1250 1050 750 750 335 290 295 670 SFC 12/12 1300 1100 850 850 400 335 345 770 SFC 15/15 1400 1200 900 900 485 408 370 820 SFC 18/18 1500 1260 1000 1000 560 480 420 920 108 www.sothvac.com

Industrial Fans SFC – Belt Drive Cabinet Fan SFC Performance Curves SFC-F 9/9 SFC 7/7 SFC 10/10 SFC 12/12 www.sothvac.com 109

SFC – Belt Drive Cabinet Fan Smoke Exhaust Fans SFC Performance Curves SFC 15/15 SFC 18/18 SFC Directions DIRECTION-1 DIRECTION- 2 DIRECTION-3 DIRECTION-4 DIRECTION-5 DIRECTION- 6 DIRECTION- 7 DIRECTION-8 R DIRECTION-9 DIRECTION-10 DIRECTION-11 DIRECTION-12 L www.sothvac.com 110

Smoke Exhaust Fans K www.sothvac.com 111

SBC – Belt Drive Cabinet Fan Industrial Fans Description : SBC Ventilation Unit can be used in the range of 500 m³/h to 100.000 m³/h air flow capacity, G4, G2, F7 etc. applicable as filter and production is made in different types and sizes if desired. * Housing structure is aluminum carcass and the corners are produced as plastic and aluminum components. * Panel thicknesses are produced as standard 25mm or optional 50mm rockwool insulated double skin, Electrostatic Powder Painted and Leak-proof Gasket. * Double Inlet Radial Fans with Belt Driven Assemblies are Used inside. * Easy installation is possible with the compact design. * It is used for supply, exhaust or pressurization for the ventilation. Factory, Hospital, Office, Laboratory, Shopping Center (shopping malls), Cafe, Restaurants, Parking lots etc. It is suitable for use in all structures which has air duct system MOTOR PROTECTION CLASS IP 55 MOTOR INSULATION CLASS F CLASS MOTOR EFFICIENCY CLASS IE2-IE3 MOTOR ENCLOSURE TYPE MOTOR BRAND TEFC BODY MATERIAL GAMAK - VOLT -WAT BODY COATING GALVANIZED SHEET METAL IMPELLER TYPE OPTIONAL POWDER COATING IMPELLER METERIAL FORWARD CURVED DUTY CYCLE GALVANIZED SHEET METAL WORKING AMBIENT TEMP DIRECTIVE IEC Duty Cycle-S1 -20 - +50 °C IEC-60335-2-80, ISO 1940-1 TECHNICAL SPECIFICATIONS AND DRAWING MODEL VOLTAGE FREQUENCY POWER REV. FLOW RATE SOUND PRESSURE WEIGHT (V) (Hz) (W) (RPM) (m3/h) dB(A) 3m (KG) 3000 70 44 SBC 280 A 230 or 380 50 1,1 2800 5500 70 45 7000 70 63 SBC 280 B 230 or 380 50 2,2 2800 8000 70 64 9500 73 84 SBC 315 A 230 or 380 50 2,2 2800 10000 73 87 13000 73 105 SBC 315 B 230 or 380 50 3 2800 15000 78 109 16000 71 134 SBC 355 A 230 or 380 50 3 2800 18500 75 139 20000 76 168 SBC 355 B 380 50 4 2800 22500 67 178 25000 80 282 SBC 400 A 380 50 4 1400 30000 85 290 SBC 400 B 380 50 5,5 1400 32500 93 325 SBC 450 A 380 50 5,5 1400 37000 97 345 SBC 450 B 380 50 7,5 1400 SBC 500 A 380 50 7,5 1400 SBC 500 B 380 50 11 1400 SBC 560 A 380 50 11 1400 SBC 560 B 380 50 15 1400 SBC 630 A 380 50 15 1400 SBC 630 B 380 50 18,5 1400 Values are for 0 Pa W H CxD B B A 104 L L1 MODEL L1 (mm) L (mm) W (mm) H (mm) B (mm) C (mm) D (mm) SBC 280 1250 1050 750 750 A (mm) 361 295 670 SBC 315 1350 1100 850 850 361 405 345 770 SBC 355 1400 1200 900 900 405 455 370 820 SBC 400 1460 1300 1100 110 455 510 470 1020 SBC 450 1560 1400 1200 1200 510 570 520 1120 SBC 500 1720 1500 1250 1250 570 640 595 1270 SBC 560 1820 1500 1350 1350 640 715 670 1420 SBC 630 2070 1700 1500 1500 715 843 745 1570 843 112 www.sothvac.com

Industrial Fans SBC – Belt Drive Cabinet Fan SBC Performance Curves SBC 280 SBC 315 SBC 355 SBC 400 www.sothvac.com 113

SBC – Belt Drive Cabinet Fan Industrial Fans SBC Performance Curves SBC 450 SBC 500 SBC 560 SBC 630 114 www.sothvac.com

Smoke Exhaust Fans K www.sothvac.com 115

CENTRALS AIR HANDLING UNITS PACKAGE TYPE DEHUMIDIFIER UNITS Our Air Handling Units are manufactured as standard in 18 different sizes with flow rates between Our Pool Dehumidifiers are used to dehumidify 1,500 m3 / h and 100,000 m3h upon request. As indoor pools. If the partial pressure of the water standard; 50 mm panel thickness, 52 kg / m3 or vapor in the ambient air is lower than the saturation 72 kg / m3 density Air Conditioner power plant pressure, evaporation occurs on the pool water module structure edge profiles, reinforcement surface. As a result, the amount of moisture in the profiles and corner elements of the skeletal structure air increases to an undesirable level. In indoor swim- used to cover the 6 sides of the cover panels are ming pools, the humidity rate should be between manufactured from galvanized sheet sandwich 40% and 64% according to VDI 2089/1. In pool de- structure. Stone wool material is in the middle part. humidification units, heat recovery plate plays a role Total panel thickness is 30 mm or 50 mm. in both dehumidification and reheating processes. It determines the need for dehumidification according ROOF TOP UNIT to many parameters such as outdoor temperature, ambient temperature, ambient humidity, and deter- Our roof-top air conditioners are manufactured as standard mines the operating mode that will meet this need in 8 different models, with a capacity range of 50 000 btu with the lowest energy consumption / h to 400,000 Btu / h. R / 410 A and R / 407 C gas are used which do not harm the environment. Heating is done 116 with heat- pump system. In very cold areas the electric heater is reinforced. Hot-water battery is used in devices without heat-pump. Since it is one piece, it provides ease of installation. Insulation material with 20 mm rubber is used in the inner parts. G4 quality panel filter is used as standard in the evaporator air inlet. The fans used are selected as belt pulleys, forward curved or back curved sparse blades. Condenser fans are of axial type and are chosen as quiet high efficiency. Condenser and evaporator coils are specially designed and feature as copper tube aluminum fin. Scroll and semihermetic compressors are used in single and tandem connection according to the capacity requirement in the cooling cycle. Roof-top air conditioners are used in hypermarkets, shopping malls, cinemas, show centers, educational institutions and factories with many industrial facilities. www.sothvac.com

RIA Ria FLEXIBLE AIR DUCTS Uninsulated model of RIA, which Ria Hygienic is manufactured as one piece, of high quality and at an affordable Hygienic model of RIA, which is price. manufactured as one piece, of high quality and at an affordable Ria Insulated price. Insulated model of RIA, which Ria Insulated Sono is manufactured as one piece, of high quality and at an affordable Insulated and sono model of RIA, price. which is manufactured as one piece, of high quality and at an Ria Insulated Hygienic affordable price. Insulated and hygienic model of Ria Insulated Hygienic Sono RIA, which is manufactured as one piece, of high quality and at an Insulated, hygienic and sono model affordable price. of RIA, which is manufactured as one piece, of high quality and at an affordable price. BOMIC Bomic - Uninsulated SESI Default model of BOMIC flexible Sesi Insulated air duct, manufactured by using PVC film on the outer surface. Particle resistant SESI's insulated model, which is manufactured Sesi with 300 denier PVC. Particle resistant SESI's uninsulated model, which is manufactured with 300 denier PVC. AVIX Avix Materiel: Polyurethane - fireproof Flame Resistance: - 30° / 150° C Diameter Range: 4\" - 12\" / 102-305 mm www.sothvac.com 117

ConnectorsFLEXIBLE AIR DUCTS Slikon Connector YKS PVC Connector Materiel: Fireproof Fabric Materiel: Materiel-Outer Jacket: 750 Denier Pvc Galvanized Materiel-Outer Jacket: Flame Resistance: Galvanized - 30° /260° Flame Resistance: - 30° / 80° C Canvas Connector PU Connector Materiel: Canvas Fabric Materiel: Materiel-Outer Jacket: Polyurethane Galvanized Materiel-Outer Jacket: Flame Resistance: Galvanized - 30° /80° Flame Resistance: - 30° / 100° C Yks Insulated Yks Hygienic It is the insulated model of YKS, a flexible flame retardant air duct It is the uninsulated hygienic made of two layers of aluminum. model of YKS, a flexible flame retardant air duct made of two Yks Insulated Hygienic layers of aluminum. It is the insulated and hygienic Yks Insulated Sono model of YKS, a flexible flame retardant air duct made of two It is the insulated and sono model layers of aluminum. of YKS, a flexible flame retardant air duct made of two layers of YKS uninsulated aluminum. Yks Insulated Hygienic Sono It is the insulated, hygienic and sono model of YKS, a flexible flame retardant air duct made of two layers of aluminum. 118 www.sothvac.com

www.sothvac.com EGG CRATE ACCESS CIRCULAR DUC SINGLE DEFLECTION GRILLE GRILLE GRILLE GRILLE LINEER TRANSFER SINGLE ROW CIRCULAR DOUBLE DEFLEFTION GRILLE GRILLE DUST GRILLE GRILLE 119 GRILLS

SWIRL DIFFUSER WITH CIRCULAR SQUARE CEILING SLOT ADJUSTABLE BLADES LOUVRE DIFFUSER DIFFUSER DIFFUSERS SWIRL DIFFUSER WITH EXTERNAL CIRCULAR CEILING DRYWALL TYPE SLOT ADJUSTABLE BLADES - S120 www.sothvac.comLOUVREDIFFUSER DIFFUSER

www.sothvac.com JET NOZZLE HIGH CAPACITY SWIRL TYPE 1 DIFFUSER JET NOZZLE METAL AIR DISC TYPE 2 VALVES 121 DIFFUSERS

CIRCULAR VARIABLE AIR RECTENGULAR FIRE RECTENGULAR VOLUME BACK DRAFT VOLUME DEVICE (VAV) DAMPER -2 CONTROL DAMPER DAMPER DAMPERS RECTENGULAR FIRE CIRCULAR 122 www.sothvac.com DAMPER DAMPER RECTENGULAR VARIABLE CIRCULAR CONSTANT AIR VOLUME DEVICE (VAV) AIR VOLUME UNIT (CAV)

www.sothvac.com HEPA FILTER RECTENGULAR BOXES ATTENUATOR LAMINOR FLOW CIRCULAR CEILING SYSTEMS ATTENUATOR 123 ATTENUATORS HYGIENIC EQUIPMENTS


Like this book? You can publish your book online for free in a few minutes!