Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore 1 - RHEEM PRODUCT CATALOGUE2018_SINGLE

1 - RHEEM PRODUCT CATALOGUE2018_SINGLE

Published by Rheem Manufacturing MEA FZE, 2018-10-04 06:27:44

Description: 1 - RHEEM PRODUCT CATALOGUE2018_SINGLE

Search

Read the Text Version

Learn more at: Product www.rheem-mea.com Catalogue 2018New information flow.indd 1 1/16/2018 4:14:44 PM

Table of Contents PRODUCT CATALOGUE 2018 Table of Contents PRODUCT CATALOGUE 2017 2 1/16/2018 4:14:46 PMNew information flow.indd 2

Why Choose RHEEM® ? 5 Timeline and History 6 Key Technology and 8 Design Philosophy RHEEM® Air Conditioning 13-107 Products • Ducted Split Units • Packaged Units • VRF • Wall Mount Split Units • Cassette Units • Floor Standing Units • Universal UnitsNew information flow.indd 3 3 1/16/2018 4:14:48 PM

4 1/16/2018 4:14:51 PMNew information flow.indd 4

Why Choose Rheem® ? It is our vision to be a strong global organization with world-class processes, a robust infrastructure, and sound cultural values. It is also our vision to be a product innovation leader in all key markets served, producing consistently high-quality products—at the right cost, delivered on time, while providing superior value and service through recognition of the diverse needs of our customers.New information flow.indd 5 5 1/16/2018 4:14:53 PM

Rheem® Manufacturing Company was established in the mid-1920s whenbrothers Richard and Donald Rheem® acquired a galvanizing plant in SanFrancisco, California. In the 1930’s, Rheem® began manufacturing waterheaters, and by 1936 had coast to coast distribution. During the 1940s and1950s, the company increased its product line to include space heating unitsfor homes, oil furnaces and air conditioners.1925: Richard S. 1970: Rheem opens 1988: Paloma Industries 1994: Rheem was the firstand Donald L. Rheem, its Air Conditioning of Nagoya, Japan, bought to adapt scroll compressorformed Rheem Division HDQ in F ort Rheem technology to its airManufacturing Smith, AK conditionersCompany 1970: Rheem advertises 1980: Rheem central heating & air launches branch in 1990 conditioning systems Middle East 1970 1980 1980: Rheem added heat pumps to its product lines 1956: Introduced t he 1992: Rheem “Rheemaire” central introduced the smallest air conditioning and gas furnace line in the heating industry A glance through our Timeline. 6 1/16/2018 4:14:53 PMNew information flow.indd 6

2010: Rheem unveiled a 2016: Rheem launches multi-year rebranding the new residential initiative at the annual AHR. AC Platform Expo that included an2009: Rheem was the entirely new visual 2013: Rheem beganfirst to introduce a appearance for its products, developing all-newcomplete line of a new website and a new product designs using14 SEER condensing tagline. its 360˚+1 productunits and heat pumps development 2012: Rheem MEA philosophy and FZE is established in introduced the Dubai residential condensing water heater2008: Rheem designedand produced thePrestigeTM Series18-SEER condensingunit 2012: Rheem launched the 2016: Rheem established first (and only) award-winning office in Saudi Arabia commercial integrated air and water heating system - H2ACNew information flow.indd 7 7 1/16/2018 4:14:54 PM

Key 1/16/2018 4:14:56 PM Technology & Design Philosophy Adoption of R410A refrigerant products With increased environmental concerns, R22 is becoming less popular. Unfortunately, the manufacture of R22 refrigerant contributes to the depletion of ozone layer and adds to global warming. Rheem® always focuses on environmentally friendly, energy saving and high performance air conditioners and hence today most of Rheem®’s products are developed with R410A refrigerant. R410A refrigerant is highly efficient and has an Ozone Depletion Potential (ODP) of 0. 8New information flow.indd 8

Fixed Compressor 9 Rheem® always works to develop robust 1/16/2018 4:15:00 PM products with simple technology. Our fixed speed compressors are reliable and easily achieve the goal of delivering high-efficiency products even at high ambient temperatures. This makes our products the most preferred choice as simple technology leads to ease of serviceability as well.New information flow.indd 9

Our Philosophy of Innovation We believe the best design delivers everything our customers need and want... And then some. The Rheem® 360˚+1 design philosophy embodies this commitment to examine every aspect of every product (and program) we develop from every angle, so we can provide the ultimate performance, installability, serviceability, durability, integration, peace of mind and partnership for consumers and industry professionals alike. The Rheem® 360˚+1 design philosophy applies to everything we do—from the way we build our products, to the way we continue to build our reputation. 360°+1 Pillars The Rheem® 360°+1 design philosophy is built around pillars that guide us in innovating even better solutions for our customers. These pillars bring our 360˚+1 design philosophy to life, helping us further explain the benefits we deliver.DRIVEN BYPHILOSOPHY ENERGY SAVINGSNew information flow.indd 10 1/16/2018 4:15:02 PM

360° Performance ® With every product we design and redesign, we set out to improve efficiency to lower operating costs and energy consumption. We balance these improvements with a commitment to including components that make our products dependable, so trade professionals can continue to offer worry-free comfort to their customers for years to come. 360° Installability ® Our innovations make installation faster, easier and more cost-effective. We coined the term Installability—a testament to how important these considerations are to Rheem® and our 360˚+1 design philosophy. 360° Serviceablity ® Our products are designed for performance that home owners can count on. Should service ever be required, our Serviceability features are specially designed to ensure fast, effective service and maintenance calls. Rheem® diagnostic systems make problem-solving quicker, and our products are designed for easy access to unit components. This means they work smarter, so service technicians don’t have to work harder. 360° Performance ® 360° Installability ® 360° Serviceability ® PlusOne® PlusOne® PlusOne® Energy Expanded Diagnostics Efficiency Valve Space PlusOne® PlusOne® PlusOne® Triple Service Heat Transfer Venting Access Technology PlusOne® PlusOne® Water Management Ignition System System PlusOne® Water SavingsNew information flow.indd 11 1/16/2018 4:15:08 PM

12 1/16/2018 4:15:10 PMNew information flow.indd 12

Ducted SplitUnitsSection ContentsDucted Splits 14-15Overview 16-43Ducted SplitsProducts • Features & Highlights • Technical Specifications 13New information flow.indd 13 13 1/16/2018 4:15:10 PM

Why choose Key BenefitsRheem®Ducted Split Louvered steel cabinet protectsUnits? the coil from damage Scroll Compressor with internal high temperature protection and durable insulation on motor windings Powder coat paint system rated at 1008 hours salt spray per ASTM-B117 High and Low pressure control for system protection during abnormal condition Low height design air handler for ease of installation 14 1/16/2018 4:15:12 PMNew information flow.indd 14

ENJOY 15 STATE OF THE ART 1/16/2018 4:15:17 PM COMFORTNew information flow.indd 15

Ducted Split Units FeaturesClassic Plus Louvered steel cabinet protects the coil fromSAGL+SHSL/SHLL (50Hz) damage Cabinet is constructed of painted galvanizedLouvered High steel rated at 1008 hours salt spray per Efficiency ASTM-B117steel cabinet Easily accessible control box Motors Single Row coil, easy to clean Bi-directional filter drier Thermostatic Metallic fan blade, increased durability Expansion Valve High and Low Pressure Control Metal blower in Air handlerHigh & Low Thermostatic expansion valve for each model High density Thermal insulationPressure Scroll Compressor with internal high Control temperature protection and durable insulation on motor windings Scroll compressor 16 1/16/2018 4:15:20 PMNew information flow.indd 16

New information flow.indd 17 SAGL + SHSL/SHLL SAGL-018T + SAGL-018T + SAGL-024T + SAGL-030T + SAGL-030T + SAGL-036T + SAGL-036T + SHLL-HM3017TA SHSL-HM3017TA SHLL-HM3017TA SHLL-HM3017TA SHSL-HM3017TA SHLL-HM4217TA SHSL-HM4217TA Rated Cooling Capacity @T1 Btu/hr 16100 16900 20000 24400 25200 30500 33670 Rated Cooling Capacity @T3 Btu/hr 15300 15300 18500 22000 22000 27000 27250 Btu/W-hr 13.2 13.0 11.7 13.2 13.1 11.7 13.0 EER @T1 Btu/W-hr EER @T3 CFM 8.4 8.3 8.4 8.4 8.3 8.4 8.3 Rated Air Flow 700 800 700 800 800 1020 1220 Rated ESP Pa 75 75 75 75 75 L (mm) 600 600 600 702 702 75 75 Sizes ODU W (mm) 600 600 600 702 702 803 803 H (mm) 616 616 616 616 616 803 803 Weight 57.2 57.2 57.6 65.3 65.3 710 710 kg 1080 1080 1080 1080 1080 75.3 75.3 Sizes IDU L (mm) 551 551 551 551 551 1080 1080 W (mm) 445 445 445 445 445 551 551 Weight H (mm) 37 37 37 37 37 445 445 Refrigerant R410A 41 41 kg SAGL + SHSL/SHLL SAGL-042T + SAGL-042N + SAGL-048N + SAGL-060N + SAGL-060N + SAGL-065N + SHLL-HM4217TA SHLL-HM4217TA SHLL-HM6021TA SHLL-HM6021TA SHLL-HM6524TA SHLL-HM6524TA Rated Cooling Capacity @T1 Btu/hr 35860 34700 45800 57000 66000 76577 Rated Cooling Capacity @T3 Btu/hr 32350 32000 39100 53000 58500 62500 Btu/W-hr 11.6 11.6 13.1 11.6 13.0 13.0 EER @T1 Btu/W-hr EER @T3 CFM 8.3 8.3 8.3 8.3 8.3 8.3 Rated Air Flow 1220 1220 1400 1900 2250 2250 Rated ESP Pa L (mm) 75 75 75 75 75 75 Sizes ODU W (mm) 803 803 803 803 803 803 H (mm) 803 803 803 803 803 803 Weight 710 710 913 913 913 913 kg 88 88 100.7 103 103 103 Sizes IDU L (mm) 1080 1080 1282 1282 1410 1410 W (mm) 551 551 551 551 551 551 Weight H (mm) 445 445 533 533 622 622 Refrigerant 41 41 68 68 82 82 kg 17 R410A1/16/2018 4:15:21 PM T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient

Ducted Split Units FeaturesClassic Plus Scroll Compressor with internal highSAGN + EL3T (50Hz) temperature protection and durable insulation on motor windings Louvered Louvered steel cabinet rated at 1008 hours Salt Spray test as per steel cabinet ASTM-B117 protects the coil from damageMetallic Easily accessible control box Bi-directional filter drierfan blade Metallic fan blade, increased durability Low height Air handler unit (10.5” high) Scroll Piston as expansion device for each model compressor Constant Torque Motor (ECM) for Indoor Unit (ECM) 18 1/16/2018 4:15:24 PMNew information flow.indd 18

New information flow.indd 19 SAGN + EL3T SAGN - 018 + EL3T1812 SAGN - 024 + EL3T2412 SAGN - 036 + EL3T3012 SAGN - 036 + EL3T3612 Rated Cooling Capacity @T1 Rated Cooling Capacity @T3 Btu/hr 19460 26000 29600 38300 Btu/hr 17450 24200 27500 34500 EER @T1 Btu/W-hr 13.0 13.0 11.8 13.2 EER @T3 Btu/W-hr Rated Air Flow CFM 9.1 9.7 9.0 9.6 L (mm) 560 800 1050 1140 Sizes ODU W (mm) 600 600 803 803 H (mm) 600 600 803 803 Weight 616 616 913 913 kg 54.9 54.9 83.5 93.9 Sizes IDU L (mm) 618 618 640 640 W (mm) 940 940 1245 1245 Weight H (mm) 265 265 265 265 Refrigerant 35.4 35.4 44.5 44.5 kg R410A T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient 191/16/2018 4:15:28 PM

Ducted Split Units FeaturesClassic Plus Heat Pump seriesSPGL+SHSL/SHLL (50Hz) Louvered steel cabinet protects the coil from damageHPigrheasnsduLroew Cabinet is constructed of powder painted Control galvanized steel Single Row coil, easy to clean DDeefmraonsd t Metallic fan blade, increased durability Metal blower in Air handler Control High density Thermal insulation Expansion Valves with Internal CheckHot Gas Valve provides quieter refrigerant meteringMuffler Demand Defrost Control Non-Cycling Reversing Valve Non-Cycling Hot Gas Muffler Easily accessible control box Reversing High and Low Pressure control Valve Slide-out design of blower housing for convenient service and maintenance Energy efficient BLDC motor (SHLL) 20 1/16/2018 4:15:30 PMNew information flow.indd 20

New information flow.indd 21 SPGL + SHSL/SHLL SPGL-024TA + SPGL-024TA + SPGL-030TA + SPGL-030TA + SPGL-036TA + SPGL-036TA + SPGL-042TA + SHSL-HM3017 SHLL-HM3017 SHSL-HM3017 SHLL-HM3017 SHSL-HM4217 SHLL-HM4217 SHSL-HM4217 Rated Cooling Capacity @AHRI Btu/hr Rated Heating Capacity @AHRI Btu/hr 20370 20640 24380 24780 29510 30266 33550 Btu/W-hr 20280 20450 24180 24590 29300 30020 33350 EER @AHRI kW/kW 11.7 12.4 12.7 13.7 11.7 13.2 11.6 COP @AHRI CFM Rated Air Flow 2.6 3.3 3.0 3.5 2.7 3.2 3.0 Rated ESP Pa 700 700 800 800 1000 1000 1200 L (mm) 75 75 75 75 Sizes ODU W (mm) 600 600 702 702 75 75 75 H (mm) 600 600 702 702 803 803 803 Weight 667 667 667 667 803 803 803 kg 59.6 59.6 67.3 67.3 695 695 899 Sizes IDU L (mm) 1080 1080 1080 1080 77.3 77.3 90.0 W (mm) 551 551 551 551 1080 1080 1080 Weight H (mm) 445 445 445 445 551 551 551 Refrigerant 37 37 37 37 445 445 445 kg R410A 37 37 37 SPGL + SHSL/SHLL SPGL-042TA + SPGL-048TA + SPGL-048TA + SPGL-048NA + SPGL-048NA + SPGL-060NA + SPGL-065NA + SHLL-HM4217 SHSL-HM6021 SHLL-HM6021 SHSL-HM6021 SHLL-HM6021 SHLL-HM6524 SHLL-HM6524 Rated Cooling Capacity @AHRI Btu/hr Rated Heating Capacity @AHRI Btu/hr 34370 34100 34920 39000 40000 53360 61830 Btu/W-hr 34180 33950 34780 38900 39920 53290 61830 EER @AHRI kW/kW 13.0 11.4 12.7 11.5 12.9 11.1 COP @AHRI CFM 9.2 Rated Air Flow 3.6 2.8 3.1 3.0 3.6 3.9 3.1 Rated ESP Pa 1200 1332 1332 1332 1332 1665 2024 L (mm) 75 Sizes ODU W (mm) 75 75 75 75 75 75 803 H (mm) 803 803 803 803 803 803 803 Weight 803 803 803 803 803 803 899 kg 899 899 899 899 899 899 105 Sizes IDU L (mm) 90.0 102.7 102.7 102.7 102.7 105 1410 W (mm) 1080 1282 1282 1282 1282 1410 551 Weight H (mm) 551 551 551 551 551 551 622 Refrigerant 445 533 533 533 533 622 82 kg 37 68 68 68 68 82 R410A 21 AHRI Condition: Cooling: 80°F/67°F On-coil, 95°F ambient1/16/2018 4:15:31 PM Heating: 47°F/43°F Outdoor air, 70°F Indoor air

Ducted Split Units FeaturesClassic Plus Louvered steel cabinet painted andSAGL+RPTL-E (50Hz) rated at 1008 hours salt spray per ASTM B117 Louvered Easily accessible control box Bi-directional Filter Drier (shipped)Steel cabinet High and Low Pressure Control Service valves are standard on all High and Low models Drawn galvanized base pan for extra Pressure corrosion resistance and sound Control reduction Low height design air handler forThermostatic ease of installation Aluminium 0.5-inch permanentExpansion washable type filters provided on all Valves units Thermostatic expansion valve is Metallic standard on all units Single Row coil, easy to clean condensor fan Metallic fan blade, increased blade durability 22 1/16/2018 4:15:34 PMNew information flow.indd 22

New information flow.indd 23 SAGL + RPTL-E SAGL-018TA + RPTL-018E SAGL-024TA + RPTL-024E SAGL-030TA + RPTL-030E SAGL-036TA/N + RPTL-036E Rated Cooling Capacity @T1 Rated Cooling Capacity @T3 Btu/hr 14916 21141 25206 29301 Btu/hr 14175 18842 22926 26190 EER @T1 Btu/W-hr 11.6 13.4 12.4 11.9 EER @T3 Btu/W-hr Rated Air Flow CFM 8.8 9.4 9.0 8.4 Rated ESP 580 850 890 1200 Pa 25 25 25 Sizes ODU L (mm) 600 600 702 50 W (mm) 600 600 702 803 Weight H (mm) 616 616 616 803 57.2 57.6 65.3 710 Sizes IDU kg 1026 1152 1152 75.3 L (mm) 564 564 564 1152 Weight W (mm) 300 300 300 614 Refrigerant H (mm) 31 33 33 350 35 kg R410A SAGL + RPTL-E Btu/hr SAGL-042TA/NA + RPTL-042E SAGL-048NA + RPTL-048E SAGL-060NA + RPTL-060E Rated Cooling Capacity @T1 Btu/hr Rated Cooling Capacity @T3 Btu/W-hr 38144 39447 56200 Btu/W-hr 33976 36732 50800 EER @T1 CFM 12.6 12.0 EER @T3 9.4 Rated Air Flow Pa 9.1 9.0 8.1 Rated ESP L (mm) 1475 1600 1900 W (mm) 50 Sizes ODU H (mm) 50 50 803 803 803 803 Weight kg 803 803 913 L (mm) 710 913 103 Sizes IDU W (mm) 88 100.7 1444 H (mm) 1152 1152 614 Weight 614 614 400 Refrigerant kg 400 400 48 43 43 R410A 23 T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient1/16/2018 4:15:36 PM

Ducted Split Units FeaturesClassic Plus Louvered steel cabinet painted andSAGL+RHLH (50Hz) rated at 1008 hours salt spray per ASTM-B117 Louvered Easily accessible control box Bi-directional Filter DrierSteel cabinet High and Low Pressure Control Low height design air handler for ease Built in of installation Microprocessor Enhanced blower housing design with lower sound level controller 12 mm thick irradiated grade fire retardant EPE insulationThermostatic Thermostatic Expansion Valves are standard for all modelsExpansion Built-in antifreeze protection Valves Built-in Microprocessor controller Scroll Compressor with internal high Scroll temperature protection and durable insulation on motor windings compressor 24 1/16/2018 4:15:40 PMNew information flow.indd 24

New information flow.indd 25 SAGL + RHLH Btu/hr SAGL-018TA + RHLH-018TM SAGL-024TA + RHLH-024TM SAGL-030TA + RHLH-030TM SAGL-036TA + RHLH-036TM SAGL-036TA + RHLH-042TM Rated Cooling Capacity @AHRI Btu/hr Btu/hr 15400 20700 24000 28800 29600 Rated Cooling Capacity @T1 Btu/W-hr 15300 20600 24000 28700 29600 Rated Cooling Capacity @T3 Btu/W-hr 13700 18900 21200 26200 27300 CFM 12.0 11.7 11.7 11.8 12.0 EER @T1 EER @T3 Pa 8.6 8.4 8.3 8.5 8.7 Rated Air Flow L (mm) 610 790 945 1225 1290 Rated ESP W (mm) 25 25 25 H (mm) 600 600 600 37 37 Sizes ODU 600 600 600 803 803 kg 616 616 616 803 803 Weight L (mm) 57.2 57.6 65.3 710 710 W (mm) 1252 1252 1252 75.3 75.3 Sizes IDU H (mm) 600 600 600 1252 1252 310 310 310 700 700 Weight kg 37 37 42 400 400 Refrigerant R410A 52 52 SAGL + RHLH SAGL-042TA + RHLH-042TM SAGL-042NA + RHLH-042TM SAGL-048NA + RHLH-054TM SAGL-060NA + RHLH-065TM Rated Cooling Capacity @AHRI Btu/hr 34900 35100 40600 56800 Rated Cooling Capacity @T1 Btu/hr 34800 35000 40500 56800 Rated Cooling Capacity @T3 Btu/hr 30900 31900 37200 50600 Btu/W-hr 11.9 11.2 12.0 11.2 EER @T1 Btu/W-hr EER @T3 CFM 8.4 8.2 8.9 8.1 Rated Air Flow 1290 1290 1720 1990 Rated ESP Pa L (mm) 37 37 37 50 Sizes ODU W (mm) 803 803 803 803 H (mm) 803 803 803 803 Weight 710 710 913 913 kg 88 88 100.7 103 Sizes IDU L (mm) 1252 1252 1652 1652 W (mm) 700 700 700 900 Weight H (mm) 400 400 400 400 Refrigerant 52 52 68 76 kg R410A 25 AHRI Condition: 80°F/67°F On-coil, 95°F ambient T1 Condition: 27°C/19°C On-coil, 35°C ambient1/16/2018 4:15:43 PM T3 Condition: 29°C/19°C On-coil, 46°C ambient

Ducted Split Units FeaturesClassic Low height air handler withRAHM+RHLH (50Hz) side-discharge condensing unit Anti-freeze temperature sensor is Anti-freeze provided on coil against freezing during abnormal operating conditions Temperature Microprocessor Based Controller Sensor Filter drier is supplied loose as standard accessory Low Low ambient kit for protection of Ambient refrigeration system operation under low ambient conditions kit Removable panels at the bottom of the unit are provided for service access Microprocessor Metallic Condenser fan blades and Based Controller evaporator blower ensure safety & high durability Hydrophilic High Pressure and Low Pressure safety controls are a standard feature coated coils on all the models Single Phase reversal and phase imbalance protection module for safety of compressors Hydrophilic Coated coils in both indoor and outdoor 26 1/16/2018 4:15:46 PMNew information flow.indd 26

New information flow.indd 27 RAHM + RHLH Btu/hr RAHM-012TR + RAHM-018TR + RAHM-024TR + RAHM-030TR + RAHM-036TR + Btu/hr RHLH-012TO RHLH-018TO RHLH-024TO RHLH-030TO RHLH-042TO Rated Cooling Capacity @T1 Btu/W-hr Rated Cooling Capacity @T3 Btu/W-hr 11600 17800 21200 24500 30100 CFM 10400 15500 19200 21400 27500 EER @T1 11.7 11.9 12.4 11.7 12.0 EER @T3 Pa Rated Air Flow L (mm) 8.7 8.6 9.4 8.6 9.1 Rated ESP W (mm) 500 650 790 890 1250 H (mm) 25 25 25 25 Sizes ODU 850 850 850 850 37 kg 310 310 310 310 1020 Weight L (mm) 790 790 790 790 416 W (mm) 49 58 60 60 960 Sizes IDU H (mm) 977 977 1252 1252 600 600 600 600 83 Weight kg 310 310 310 310 1252 Refrigerant 34 36 37 42 700 R410A 400 52 RAHM + RHLH Btu/hr RAHM-024TS + RAHM-030TS + RAHM-036TS + RAHM-042TS + RAHM-042MS + Btu/hr RHLH-024TM RHLH-030TM RHLH-036TM RHLH-042TM RHLH-042TM Rated Cooling Capacity @T1 Btu/W-hr Rated Cooling Capacity @T3 Btu/W-hr 21900 25200 29500 37400 38100 CFM 19800 22900 27100 33800 34100 EER @T1 12.2 11.8 12.0 11.9 11.9 EER @T3 Pa Rated Air Flow L (mm) 9.2 8.4 9.0 8.8 8.6 Rated ESP W (mm) 790 890 1275 1355 1355 H (mm) 25 25 Sizes ODU 850 850 37 37 37 kg 310 310 1020 1020 1020 Weight L (mm) 790 790 416 416 416 W (mm) 60 60 960 960 960 Sizes IDU H (mm) 1252 1252 600 600 72 82 82 Weight kg 310 310 1252 1252 1252 Refrigerant 37 42 700 700 700 400 400 400 52 52 52 R410A RAHM + RHLH RAHM-048MS + RAHM-054MS + RAHM-054MS + RAHM-065MS + RHLH-048TM RHLH-054TM RHLH-065TM RHLH-065TM Rated Cooling Capacity @T1 Rated Cooling Capacity @T3 Btu/hr 39000 45400 48900 58700 Btu/hr 34600 40300 44000 51000 EER @T1 Btu/W-hr 11.8 11.8 12.3 11.7 EER @T3 Btu/W-hr Rated Air Flow CFM 8.4 8.6 9.1 8.4 Rated ESP 1495 1645 1990 1990 Pa Sizes ODU L (mm) 37 50 50 50 W (mm) 1020 1020 1020 1020 Weight H (mm) 416 416 416 416 960 1045 1045 1045 Sizes IDU kg L (mm) 92 89 89 95 Weight W (mm) 1652 1652 1652 1652 Refrigerant H (mm) 700 700 900 900 400 400 400 400 kg 68 68 76 76 27 R410A1/16/2018 4:15:48 PM T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient

Ducted Split Units FeaturesClassic Low height air handler withRSON+RSIN (50Hz) side-discharge condensing unit Anti-freeze temperature sensor isAnti-freeze provided on coil against freezing during abnormal operating conditionsTemperature Microprocessor Based Controller Sensor Filter drier is supplied loose as standard accessory High and Low Removable panels at the bottom of the unit are provided for service access Pressure Quick connector for interconnecting Control communication cable (10 meter Long) from main controller to Controller UserMicroprocessor InterfaceBased Controller Metallic Condenser fan blades and evaporator blower ensure safety & Metallic high durability High Pressure and Low Pressure condensor fan safety controls are a standard feature blade on all the models 28 1/16/2018 4:15:52 PMNew information flow.indd 28

New information flow.indd 29 RSON + RSIN (Rotary) RSON-012TR + RSIN-012T RSON-018TR + RSIN-018T RSON-021TR + RSIN-021T RSON-024TR + RSIN-024T RSON-030TR + RSIN-030T Rated Cooling Capacity @T1 Btu/hr 11948 17857 21396 25748 30098 Rated Cooling Capacity @T3 Btu/hr 10000 15300 18300 21300 24900 Btu/W-hr 11.8 11.81 11.83 11.83 11.81 EER @T1 Btu/W-hr 8.36 8.59 8.13 8.14 EER @T3 CFM 8.2 1250 Rated Air Flow 500 650 790 890 Rated ESP Pa 25 25 25 25 37 L (mm) 850 850 850 850 850 Sizes ODU W (mm) 310 310 310 310 310 H (mm) 550 690 690 790 790 Weight 36 50 50 55 58 kg 977 977 1252 1252 1252 Sizes IDU L (mm) 600 600 600 600 700 W (mm) 310 310 310 310 400 Weight H (mm) 37 38 44 44 58 Refrigerant R410A kg T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient 291/16/2018 4:15:55 PM

Ducted Split Units FeaturesClassic Low height air handler with side-discharge condensing unitRSON + RSIN SCROLL (50Hz) Anti-freeze temperature sensor is provided on coil against freezingAnti-freeze during abnormal operating conditions Microprocessor Based ControllerTemperature Filter drier is supplied loose as Sensor standard accessory Removable panels at the bottom of the High and Low unit are provided for service access Quick connector for interconnecting Pressure communication cable (10 meter Long) Control from main controller to Controller User InterfaceMicroprocessor Metallic Condenser fan blades andBased Controller evaporator blower ensure safety & high durability Metallic High Pressure and Low Pressure safety controls are a standard feature condensor fan on all the models blade 30 1/16/2018 4:15:57 PMNew information flow.indd 30

New information flow.indd 31 RSON + RSIN (Scroll) RSON-021TS RSON-025TS RSON-030TS RSON-036NS RSON-036TS + RSON-042NS RSON-048NS RSON-054NS Rated Cooling Capacity @AHRI + RSIN-021T + RSIN-025T + RSIN-029T + RSIN-036T RSIN-036T + RSIN-042T + RSIN-048T + RSIN-054T Rated Cooling Capacity @T3 Btu/hr 22100 27000 29200 37200 37400 40100 46300 59300 EER @AHRI Btu/hr 20400 24000 25500 35400 40700 53300 EER @T3 Btu/W-hr 11.6 11.6 11.7 29200 29500 11.8 11.6 11.5 Btu/W-hr 10.7 10.3 10.2 10.4 10.1 10.3 Rated Air Flow CFM 1275 11.6 11.6 1560 1560 2040 Rated ESP 790 890 Pa 25 25 37 9.1 9.1 37 50 50 Sizes ODU L (mm) 850 850 1020 1020 1020 1020 W (mm) 310 310 416 1290 1290 416 416 416 Weight H (mm) 690 800 930 930 930 1045 53 57 37 37 110 Sizes IDU kg 1252 1252 78 90 92 1652 L (mm) 600 600 1252 1020 1020 1402 1402 700 Weight W (mm) 310 310 700 700 700 400 Refrigerant H (mm) 44 44 400 416 416 400 400 72 kg 55 930 930 64 64 86 86 1252 1252 700 700 400 400 58 58 R410A AHRI Condition: 80°F/67°F On-coil, 95°F ambient T3 Condition: 80°F/67°F On-coil, 115°F ambient 311/16/2018 4:15:58 PM

Ducted Split Units FeaturesClassic Plus Scroll Compressor with internal highEA14+EH1T (60Hz) temperature protection and durable insulation on motor windingsOptimized New New composite base pan Powder coat paint system rated at fan orifice Composite 1008 hours salt spray per ASTM-B117 Optimized fan orifice base pan Single-row condenser coil allows thorough coil cleaning High and Low High and Low pressure switches for unit and compressor protection Pressure Metal blower in Air handler Switches Thermostatic expansion valve for each modelScroll High density Thermal insulation Energy-efficient BLDC motor in indoorcompressor unit 32 1/16/2018 4:16:01 PMNew information flow.indd 32

New information flow.indd 33 EA14 + EH1T EA1418 + EA1424 + EA1430 + EA1436 + EA1442 + EA1448 + EA1460 + EH1T2417 EH1T2417 EH1T3617 EH1T3617 EH1T4821 EH1T4821 EH1T6024 Rated Cooling Capacity @AHRI Btu/hr Rated Cooling Capacity @T3 Btu/hr 18000 24000 29400 35600 41000 46500 58000 EER @AHRI Btu/W-hr 16200 20200 24700 29150 34700 40600 47500 EER @T3 Btu/W-hr 13.0 13.0 13.0 12.5 12.0 12.5 12.0 Rated Air Flow CFM L (mm) 9.3 8.4 8.5 8.6 8.5 8.5 8.3 Sizes ODU W (mm) 600 800 1000 1200 1400 1400 1600 H (mm) 755 755 755 857 859 908 908 Weight 755 755 755 857 859 908 908 kg 635 635 685 685 787 787 889 Sizes IDU L (mm) 55.3 63.9 68.5 77.6 90.7 100.3 108.8 W (mm) 1080 1080 1080 1080 1282 1282 1410 Weight H (mm) 551 551 551 551 551 551 551 Refrigerant 445 445 445 445 533 533 622 kg 48 48 50 50 65 65 80 R410A AHRI Condition: 80°F/67°F On-coil, 95°F ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient 331/16/2018 4:16:04 PM

Ducted Split Units FeaturesClassic Plus Heat PumpEP14 + EH1T (60Hz) Scroll Compressor with internal high temperature protection and durableHeat Pump New insulation on motor windings Composite New composite base pan Series Powder coat paint system rated at base pan 1008 hours salt spray per ASTM-B117 Optimized fan orifice PHirgeh sansduLroew Single-row condenser coil allows Switches thorough coil cleaning High and Low pressure switches forOptimized unit and compressor protectionfan orifice Metal blower in Air handler Thermostatic expansion valve for each model High density Thermal insulation Energy-efficient BLDC motor in indoor unit 34 1/16/2018 4:16:09 PMNew information flow.indd 34

New information flow.indd 35 EP14 + EH1T EP1418 + EP1424 + EP1430 + EP1436 + EP1442 + EP1448 + EP1460 + EH1T2417 EH1T2417 EH1T3617 EH1T3617 EH1T4821 EH1T4821 EH1T6024 Rated Cooling Capacity @AHRI Btu/hr Rated Cooling Capacity @T3 Btu/hr 18800 23800 29400 35200 42500 47000 58000 EER @AHRI Btu/W-hr 19000 23000 24500 30000 37000 38500 49000 EER @T3 Btu/W-hr 11.5 11.5 13.0 11.5 12.5 12.5 12.5 Rated Air Flow CFM L (mm) 9.7 8.9 9.4 8.4 8.6 8.7 9.1 Sizes ODU W (mm) 575 825 1025 1200 1350 1500 1775 H (mm) 755 600 857 857 857 908 908 Weight 755 600 857 857 857 908 908 kg 635 666 787 685 889 990 1143 Sizes IDU L (mm) 67.6 65.8 72.6 84.8 81.6 94.3 107.0 W (mm) 1080 1080 1080 1080 1282 1282 1410 Weight H (mm) 551 551 551 551 551 551 551 Refrigerant 445 445 445 445 533 533 622 kg 48 48 50 50 65 65 80 R410A AHRI Condition: 80°F/67°F On-coil, 95°F ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient 351/16/2018 4:16:10 PM

Ducted Split Units FeaturesClassic Plus Scroll Compressor with internal highEA14 + EL3T(60Hz) temperature protection and durable insulation on motor windings Optimized New composite base pan Powder coat paint system rated at fan orifice 1008 hours salt spray per ASTM-B117 Optimized fan orificeNew composite Scroll Single-row condenser coil allows Compressor thorough coil cleaning base pan High and Low pressure switches for unit and compressor protectionLow-height Low height Air handler unit (10.5” high) Piston as expansion device for each air-handler model Constant Torque Motor (ECM) for Indoor Unit 36 1/16/2018 4:16:13 PMNew information flow.indd 36

New information flow.indd 37 EA14 + EL3T EA1418 + EL3T1812 EA1424 + EL3T2412 EA1436 + EL3T3012 EA1436 + EL3T3612 Rated Cooling Capacity @AHRI Btu/hr 17500 25000 33750 35750 Rated Cooling Capacity @T3 Btu/hr 16500 22500 30500 32500 EER @AHRI Btu/W-hr 13.2 13.2 13.1 13.0 EER @T3 Btu/W-hr 10.0 Rated Air Flow CFM 9.6 9.6 9.6 L (mm) 570 730 950 1190 Sizes ODU W (mm) 755 755 755 857 H (mm) 755 755 755 857 Weight 635 635 685 685 kg 55.3 77.6 Sizes IDU 618 63.9 68.5 640 L (mm) 940 1245 Weight W (mm) 265 618 640 265 Refrigerant H (mm) 35.4 940 1245 44.5 265 265 kg 35.4 44.5 R410A AHRI Condition: 80°F/67°F On-coil, 95°F ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient 371/16/2018 4:16:19 PM

Ducted Split Units FeaturesPrestige Stamped louver panels offer 100%SAWL+SHGL(50Hz) protection for the condenser coil Scroll Compressor with internal highSlotaumvpeedr Galvanised temperature protection and durable Steel basepan insulation on motor windings panels Crankcase heater to prevent liquid and cabinet refrigerant migration to compressor Low ambient control (optional) allows Thermostatic operation of unit down to 0°F High and Low pressure control for system Expansion Valves protection during abnormal condition Compressor Time Delay Control on Scroll tandem compressorsCompressor Filter drier as standard feature for each unit Interlaced Thermostatic Expansion Valves are standard for all models evaporator coil One-inch throw-away filter is standard for all models Basepan and cabinet are made of G90 galvanized steel with a durable paint finish capable of withstanding 1008-Hr salt spray test per ASTM-B117 Evaporator coil has two circuit, interlaced row split coils 38 1/16/2018 4:16:21 PMNew information flow.indd 38

New information flow.indd 39 SAWL + SHGL SAWL-078NAZ + SHGL-090N SAWL-090NAZ + SHGL-090N SAWL-120NAZ + SHGL-120N SAWL-125NAZ + SHGL-120N Rated Cooling Capacity @T1 Rated Cooling Capacity @T3 Btu/hr 68600 82000 114000 112000 Btu/hr 59500 71000 110000 94000 EER @T1 Btu/W-hr 12.9 12.6 14.3 EER @T3 Btu/W-hr 15.4 Rated Air Flow CFM 9.3 8.9 11.0 9.5 Rated ESP 2200 2300 3165 3165 Pa 75 Sizes ODU L (mm) 62 62 1540 75 W (mm) 1092 1092 975 1540 Weight H (mm) 789 789 1137 975 833 833 227.3 1137 Sizes IDU kg 132 144.2 1454 265.8 L (mm) 1454 1454 1422 1454 Weight W (mm) 1422 1422 800 1422 Refrigerant H (mm) 800 800 157 800 150 150 157 kg R410A SAWL + SHGL SAWL-150NAZ + SHGL-180N SAWL-180NAZ + SHGL-180N SAWL-240NAZ + SHGL-240N Rated Cooling Capacity @T1 Btu/hr 154000 150800 191400 Rated Cooling Capacity @T3 Btu/hr 133000 129000 167850 Btu/W-hr EER @T1 Btu/W-hr 15.0 11.6 10.0 EER @T3 CFM 10.6 8.1 7.2 Rated Air Flow 4165 4250 5700 Rated ESP Pa 87 87 99 L (mm) 1838 2219 2219 Sizes ODU W (mm) 975 975 975 H (mm) 1137 1137 1137 Weight 294.8 338.4 431.8 kg 1943 1943 1943 Sizes IDU L (mm) 1600 1600 1600 W (mm) 991 991 991 Weight H (mm) 225 225 247 Refrigerant R410A kg 39 T1 Condition: 27°C/19°C On-coil, 35°C ambient T3 Condition: 29°C/19°C On-coil, 46°C ambient1/16/2018 4:16:21 PM

Ducted Split Units FeaturesPrestige Stamped louver panels offer 100%SAWL+SHGL(60Hz) protection for the condenser coil Scroll Compressor with internal highSlotaumvpeedr Galvanised temperature protection and durable Steel basepan insulation on motor windings panels Crankcase heater to prevent liquid and cabinet refrigerant migration to compressor Low ambient control (optional) allows Thermostatic operation of unit down to 0°F High and Low pressure control for system Expansion Valves protection during abnormal condition Compressor Time Delay Control on Scroll tandem compressorsCompressor Filter drier as standard feature for each unit Interlaced Thermostatic Expansion Valves are standard for all models evaporator coil One-inch throw-away filter is standard for all models Basepan and cabinet are made of G90 galvanized steel with a durable paint finish capable of withstanding 1008-Hr salt spray test per ASTM-B117 Evaporator coil has two circuit, interlaced row split coils 40 1/16/2018 4:16:26 PMNew information flow.indd 40

New information flow.indd 41 SAWL + SHGL Btu/hr SAWL-078CAZ + SAWL-078VAZ + SAWL-090CAZ + SAWL-090CAZ + SAWL-090VAZ + SAWL-090VAZ + SAWL-120CAZ + Rated Cooling Capacity @AHRI Btu/W-hr SHGL-090Z SHGL-090V SHGL-090Z SHGL-120Z SHGL-090V SHGL-120V SHGL-120Z 77000 77000 90000 92000 90000 92000 117000 EER @AHRI CFM 11.2 11.2 11.2 11.4 11.2 11.4 11.2 Rated Air Flow Pa 2600 2600 2800 2800 2800 2800 3800 62 62 62 75 62 75 75 Rated ESP L (mm) 1092 1092 1092 1092 1092 1092 1540 W (mm) 789 789 789 789 789 789 975 Sizes ODU H (mm) 833 833 833 833 833 833 1137 132 132 144.2 144.2 144.2 144.2 227.3 Weight kg 1454 1454 1454 1454 1454 1454 1454 L (mm) 1422 1422 1422 1422 1422 1422 1422 Sizes IDU W (mm) 800 800 800 800 800 800 800 H (mm) 150 150 150 157 150 157 157 Weight R410A Refrigerant kg SAWL + SHGL Btu/hr SAWL-120VAZ + SAWL-150CAZ + SAWL-150VAZ + SAWL-180CAZ + SAWL-180VAZ + SAWL-240CAZ + SAWL-240VAZ + Rated Cooling Capacity @AHRI SHGL-120V SHGL-180Z SHGL-180V SHGL-180Z SHGL-180V SHGL-240Z SHGL-240V 146000 146000 178000 178000 244000 244000 117000 11.1 11.1 11.0 11.0 10.0 10.0 5000 5000 5100 5100 6900 6900 EER @AHRI Btu/W-hr 11.2 87 87 87 87 99 99 1838 1838 2219 2219 2219 2219 Rated Air Flow CFM 3800 975 975 975 975 975 975 1137 1137 1137 1137 1137 1137 Rated ESP Pa 75 294.8 294.8 338.4 338.4 431.8 431.8 1943 1943 1943 1943 1943 1943 L (mm) 1540 1600 1600 1600 1600 1600 1600 991 991 991 991 991 991 Sizes ODU W (mm) 975 225 225 225 225 247 247 R410A H (mm) 1137 Weight kg 227.3 L (mm) 1454 Sizes IDU W (mm) 1422 H (mm) 800 Weight kg 157 Refrigerant AHRI Condition: 80°F/67°F On-coil, 95°F ambient 41 `1/16/2018 4:16:26 PM

Ducted Split Units FeaturesClassic Plus Polyester powder coated tested andRFTL+RDTL (50Hz) rated at 1008 hours salt spray per ASTM-B117 Intelligent Lower sound levels with enhance Defrost blower housing Function Metallic condenser fan blade, increased durabilityHeat Pump High and Low Pressure Control Series Galvanized steel drain pan insulated with polyethylene foam High and low Compressor delay and minimum on Pressure time Control Low height design air handler for ease of installation Freeze Aluminium permanent washable typeProtection filters provided on all units Freeze protection Intelligent defrost function Low ambient protection 42 1/16/2018 4:16:29 PMNew information flow.indd 42

New information flow.indd 43 RFTL + RDTL Btu/hr RFTL-012HTA + RFTL-018HTA + RFTL-024HTA + RFTL-030HTA + RFTL-036HTA + Nominal Cooling Capacity @AHRI Btu/hr RDTL-012 RDTL-018 RDTL-024 RDTL-030 RDTL-036 Nominal Heating Capacity @AHRI Btu/W-hr 12000 18000 23000 28500 36000 Btu/W-hr 12480 18720 24400 28700 37440 EER @AHRI CFM 10.1 10.3 10.6 11.4 10.7 COP @AHRI 3.6 3.7 3.6 4.1 3.6 Rated Air Flow Pa 380 665 760 1130 1235 Rated ESP L (mm) 25 25 25 25 50 W (mm) 850 950 950 950 980 Sizes ODU H (mm) 285 370 370 370 390 545 695 695 695 795 Weight kg 36 50 58 65 75 L (mm) 899 1026 1152 1152 1152 Sizes IDU W (mm) 564 564 564 614 614 H (mm) 300 300 300 350 400 Weight 19 31 38 40 42 Refrigerant kg R410A RFTL-042HTA + RFTL-048HNA + RFTL-060HNA + RFTL+RDTL Btu/hr RFTL-036HNA + RDTL-042 RFTL-042HNA + RDTL-048 RDTL-060 Nominal Cooling Capacity @AHRI Btu/hr RDTL-036 41000 RDTL-042 48000 56000 Nominal Heating Capacity @AHRI Btu/W-hr 36000 42600 41000 49920 58000 Btu/W-hr 37440 11.2 42600 10.6 11.3 EER @AHRI CFM 10.7 3.8 11.5 3.8 4.1 COP @AHRI 3.6 1349 4.0 1520 1829 Rated Air Flow Pa 1235 50 1349 50 50 Rated ESP L (mm) 50 980 50 1100 1100 W (mm) 980 390 980 400 400 Sizes ODU H (mm) 390 795 390 1105 1105 795 79 795 98 107 Weight Kg 75 1152 79 1152 1152 L (mm) 1152 614 1152 614 614 Sizes IDU W (mm) 614 400 614 400 400 H (mm) 400 45 400 45 47 Weight 42 45 Refrigerant Kg R410A 43 AHRI Condition: Cooling: 80°F/67°F On-coil, 95°F ambient1/16/2018 4:16:30 PM Heating: 47°F/43°F Outdoor air, 70°F Indoor air














Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook