Sentinel Sentinel Single Phase Consumer Unit Range www.europacomponents.com Sales: 01582 692 440 Technical: 01582 692 444
Sentinel NeedHelp? -Call: 01582 692 440 Dual RCCB with MCB Boards 1 High Integrity Metal Encl. 2 Surge Protection 3 Mainswitch 4 Type ‘A’ RCCB 5 MCBs 6 Generous Wiring Space 7 Knockouts 8 Earth & Neutral Bars 9 Busbar 68 1 7 23 45 • High Integrity flexible solution (Flexible busbar provided) 9 • All consumer units provided with Type ‘A’ RCCB • Type 2 SPD available to protect from transient overvoltage (where fitted) • Earth and neutral bars positioned at the top and clearly labelled • Top, bottom and side knockouts for cable entries • Busbar with cover and fingertip protection included • Retain-screws for lid prevents them from being lost during installation Part Number Modules No. of Description Knockouts Usable Top / Bottom Side Ways (32mm) (25mm) (32mm) SLCU16DS-FL01 16 10 100A Main switch + 2 80A RCCBs Type A 4 + 8 MCBs (2 x 6A, 2 x 16A, 3 x 32A, 1 x 40A) + 2 Blanks 14 SLCU20DS-FL01 20 100A Main switch + 2 80A RCCBs Type A 6 10 + 10 MCBs (3 x 6A, 2 x 16A, 4 x 32A, 1 x 40A) + 4 Blanks 22 12 100A Main switch + 2 80A RCCBs Type A SLCU18DS-SPD-FL01 18 + 8 MCBs (2 x 6A, 2 x 16A, 3 x 32A, 1 x 40A) + SPD/MCB + 2 Blanks 5 SLCU20DS-SPD-FL01 20 100A Main switch + 2 80A RCCBs Type A 6 + 10 MCBs (3 x 6A, 2 x 16A, 4 x 32A, 1 x 40A) + SPD/MCB + 2 Blanks wwwwww..eeuurrooppaaccoommppoonneennttss..ccoomm SSaalleess:: 0011558822 669922 444400 TTeecchhnniiccaall:: 0011558822 669922 444444
Sentinel NeedHelp? -Call: 01582 692 440 Main Switch Boards • High Integrity flexible solution • Type 2 SPD available to protect from transient overvoltage (where fitted) • Earth and neutral bars positioned at the top and clearly labelled • Top, bottom and side knockouts for cable entries • Busbar with cover and fingertip protection included • Retain-screws for lid prevents them from being lost during installation • Fitted with 100A Main Switch incomer which can be changed to an RCCB incomer (sold seperately) No. of Knockouts Usable Ways Part Number No. of Ways Description Top / Bottom Side SLCU6M 6 (32mm) (25mm) (32mm) SLCU8M 8 SLCU10M 10 4 C/w 100A Main switch Incomer + 2 Blanks 1 SLCU14M 14 6 C/w 100A Main switch Incomer + 2 Blanks 1 SLCU20M 20 8 C/w 100A Main switch Incomer + 2 Blanks 12 C/w 100A Main switch Incomer + 2 Blanks 22 18 C/w 100A Main switch Incomer + 2 Blanks 2 3 6 Type A RCBO Board Solutions... • All Main Switch Boards designed for Type ‘A’ RCBO’s • Extra wiring space provided by compact RCBO design • Suitable for smooth DC fault currents <6mA • Selection of RCBOs specified by customer • Any configuration possible Compact Type A RCBO See Configuration Examples Below Board Part Number Modules No. of Usable Ways Common Type A RCBO Configurations Example SLCU10M 10 8 6 RCBOs - 2 x 6A, 1 x 16A, 2 x 32A, 1 x 40A * SLCU14M 14 12 10 RCBOs - 4x 6A, 1 x 16A, 4 x 32A, 1 X 40A * SLCU20M 20 18 12 RCBOs - 4 x 6A, 1 x 10A, 2 x 16A, 4 x 32A & 1 x 40A * * RCBOs supplied separately - part number EUB1RC.*/1BA (* equals amperage) Above examples also leave room for Type 2 SPD to be fitted wwwwww..eeuurrooppaaccoommppoonneennttss..ccoomm SSaalleess:: 0011558822 669922 444400 TTeecchhnniiccaall:: 0011558822 669922 444444
Sentinel NeedHelp? -Call: 01582 692 440 Dual RCCB Boards • High Integrity flexible solution (Flexible busbar provided) • All consumer units provided with Type ‘A’ RCCB • Earth and neutral bars positioned at the top and clearly labelled • Top, bottom and side knockouts for cable entries • Busbar with cover and fingertip protection included • Retain-screws for lid prevents them from being lost during installation Part Number Modules No. of Description Knockouts Usable Ways Top / Bottom Side SLCU14DS 14 (32mm) (25mm) (32mm) SLCU16DS 16 8 100A Main switch + 2 80A RCCBs Type A + 2 Blanks SLCU18DS 18 10 100A Main switch + 2 80A RCCBs Type A + 2 Blanks 3 SLCU20DS 20 12 100A Main switch + 2 80A RCCBs Type A + 2 Blanks SLCU24DS-DT 24 (2x12) 14 100A Main switch + 2 80A RCCBs Type A + 2 Blanks 4 SLCU36DS-DT 36 (2x18) 18 100A Main switch + 2 80A RCCBs Type A + 2 Blanks 30 100A Main switch + 2 80A RCCBs Type A + 2 Blanks 252 6 3 4 5 Surge Protected Boards Available SPD-installed versions are suitable for buildings and dwellings that do not have an external lightning protection system, a non-metallic roof and where the power source is fed from underground. • Type 2 SPD wired adjacent to a 32A MCB to protect the circuits connected to the consumer unit. • Meet the 18th Edition requirements • Protection from transient overvoltage by Type 2 SPD Compact Garage Unit • Compact Size • Provided with Type ‘A’ RCCB • Earth and neutral bars positioned at the top and clearly labelled • Top and bottom knockouts for cable entries • Retain-screws for lid prevents them from being lost during installation Part Number Modules No. of Usable Ways Description GRGC16M 4 2 63A RCCB Type A + 1 x 6A & 1 x 16A MCBs wwwwww..eeuurrooppaaccoommppoonneennttss..ccoomm SSaalleess:: 0011558822 669922 444400 TTeecchhnniiccaall:: 0011558822 669922 444444
Search
Read the Text Version
- 1 - 4
Pages: