EPA/HEPA/ULPA 0Laminarven 78 mm INFORMA- TIONAbsolute Filtration / Clean RoomsClass: E, H and U 1Terminal or air return filtration in clean rooms and lami- PRE-nar flow cabins FILTERSFeatures techniques Dimensions Certification G2-G4Type: Laminar Flow HEPA Panel. 2Frame: Extruded and anodised aluminium profile.Filtering Element: Glass microfibre paper. PAINTINGSSeparators: Thermoplastic glue beads. BOOTHSSealant: Polyurethane.Protective grille: Steel grille painted on both sides with 3white epoxy.Joint: Gasket with plane profile of neoprene. PRODUCTSMPPS Efficiency: 85%, 99.95% and 99.995% CONFORClass EN 1822: E10, H13 and H14 M5-F9Recommended Final Pressure Loss: 600 Pa.Temperature: 80ºC in continuous service. 4Advantages EPA/HEPA /ULPA- Extruded anodized aluminium frame, avoids particle detachment present in agglomerated frames or similar constructions materials. 5- Gird protection at the air outlet and inlet to prevent filter surfaces breakages. HIGH- This method of V-shaped pleating guarentees the optimal geometry characteristics for the folds and a TEMPERA- uniform distance betwen them, resulting in a reduced load loss with greater airflow. TURE- 100% sacnned in accordance with regulation EN 1822-4.- DOUBLE LABELLING ATTACHED. 6Photo detail joint: EQUIP-Plane of neoprene MENTS Venfilter [email protected] 7 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 99 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- References TION Reference Model Dimensions Efficiency Class EN Filtering Rated flow Unit Weight UxP Stock1 HxLxP Area (m3/h/Pa) Vol. (kg) * * LV121278H13 LV78 (MPPS E%) 1822 (m2) (m3) PRE- LV122478H13 LV78 125/95-250/180 1.4 1 SL FILTERS LV181878H13 LV78 305x305x78 99,95 H13 2,5 300/95-540/180 0,007 2,75 1 F LV212178H13 LV78 610x305x78 99,95 H13 5,5 340/95-600/180 0,01 3.10 1 SL G2-G4 LV222278H13 LV78 457x457x78 99,95 H13 6 460/95-850/180 0,02 4,8 1 F LV242478H13 LV78 535x535x78 99,95 H13 8,50 535/95-970/180 0,02 F2 LV243678H13 LV78 575x575x78 99,95 H13 9,9 600/95-1100/180 0,03 51 SL LV244878H13 LV78 610x610x78 99,95 H13 11 900/95-1400/180 0,03 5.5 1 FPAINTINGS LV121278H14 LV78 610x915x78 99,95 H13 16,5 1200/95-2200/180 0,04 8,25 1 F BOOTHS LV122478H14 LV78 610x1220x78 99,95 H13 22 125/120-250/230 0,06 11 1 F LV181878H14 LV78 305x305x78 99,995 H14 2,5 300/120-540/230 0,007 1.4 1 F3 LV212178H14 LV78 610x305x78 99,995 H14 5,5 340/120-600/230 0,01 2,75 1 SL LV222278H14 LV78 457x457x78 99,995 H14 6 460/120-850/230 0,02 3.10 1 FPRODUCTS LV242478H14 LV78 535x535x78 99,995 H14 8,50 535/120-970/230 0,02 4,8 1 F CONFOR LV243678H14 LV78 575x575x78 99,995 H14 9,9 600/120-1100/230 0,03 51 SL M5-F9 LV244878H14 LV78 610x610x78 99,995 H14 11 900/120-1400/230 0,03 5.5 1 F 610x915x78 99,995 H14 16,5 1200/120-2200/230 0,04 8,25 1 F4 610x1220x78 99,995 H14 22 0,06 11 1EPA/HEPA UxP (*) Stock /ULPA Units per box F: Manufacturer, S: Stock, SL: Limited Stock5 Venfilter HIGH Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 100 TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0Laminarven Plus INFORMA-90/110 mm TIONAbsolute Filtration / Clean Rooms 1Class: E, H and U PRE-Terminal or air return filtration in clean rooms and lami- FILTERSnar flow cabins. G2-G4Features techniques 2Type: Laminar Flow HEPA Panel.Frame: Extruded and anodised aluminium profile. PAINTINGSFiltering Element: Glass microfibre paper. BOOTHSSeparators: Thermoplastic glue beads.Sealant: Polyurethane. Dimensions 3Protective grille: Steel grille painted on both sides with Certificationwhite epoxy. PRODUCTSJoint: Bicomponent polyurethane liquid system. (Continuous CONFORsemi-circular expanded polyurethane.) M5-F9MPPS Efficiency: 85%, 99.95% and 99.995%Class EN 1822: E10, H13 and H14 4Recommended Final Pressure Loss: 600 Pa.Temperature: 80ºC in continuous service. EPA/HEPA /ULPA 5Advantages HIGH TEMPERA-- This method of V-shaped pleationg guarantees optimal geometrycharacteristics for the folds and a TURE uniform distance between them, resulting in a reduced load 6loss with greater airflow.- V-shaped pleated technology means that aluminium separa- EQUIP-tor con be replaced, therefore eliminating the MENTS risk of leaks due to perforations in the aluminium separa- 7tors.- The total use of the filter surface, in addition to an even dust MOTORSdeposit with the new pleat technology means AND longer-lasting equipement. TURBINES- Protection on both grid faces.- 100% sacneed, in accordance with regulation EN 1822-4.- DOUBLE LABELLING ATTACHED. 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 101 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- References TION Reference Model Dimensions Efficiency Class Filtering Rated flow Rated flow Unit vol. Weight UxP S1 HxLxP (MPPS EN Area (m2) 0.45 m/s 0.45 m/s (m3) (k) * * LV122490H14 LV90 E%) 1822 (m3/h)/ Pa (m3/h)/ Pa PRE- LV242490H14 LV90 610x305x90 7,15 0.01 31 F FILTERS LV243690H14 LV90 610X610X90 99,995 H14 14,3 300/800 85/250 0.03 71 F LV244890H14 LV90 610x915x90 99,995 H14 21,45 600/1600 85/250 0,05 91 F G2-G4 LV1224110H14 LV110 610x1220x90 99,995 H14 28,6 900/1800 85/250 0,07 12 1 F LV2424110H14 LV110 610x305x110 99,995 H14 9,50 1200/3400 85/250 0,02 51 F2 LV2448110H14 LV110 610x610x110 99,995 H14 19 300/1000 70/250 0,04 10 1 F LV122490U15 LV90 610x1120x110 99,995 H14 38 600/2000 70/250 0,08 36 1 FPAINTINGS LV242490U15 LV90 610x305x90 99,995 H14 7,15 1200/4000 75/250 0,02 61 F BOOTHS LV244890U15 LV90 610x610x90 99,9995 U15 14,3 300/750 115/300 0,03 12 1 F LV1224110U15 LV110 610x1220x90 99,9995 U15 29 600/300 115/300 0,07 25 1 F3 610x305x110 99,9995 U15 9,50 1200/3000 115/300 0.02 91 F LV2424110U15 LV110 610x610x110 99,9995 U15 19 300/1000 95/300 0.04 18 1 FPRODUCTS LV2448110U15 LV110 610x1220x110 36 0.08 36 1 F CONFOR 99,9995 U15 600/2000 95/300 M5-F9 99,9995 U15 1200/4000 95/3004 UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited StockEPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- 102 Venfilter [email protected] AND Tel +34 937 862 607 www.venfilter.comDESODO- Fax +34 937 862 493RIZATION9 INTER-NATONALNORMATI- VE
EPA/HEPA/ULPA 0 Laminarven Gel INFORMA- TION Absolute Filtration / Clean Rooms Class: H and U 1 Terminal filtration in clean rooms and laminar flow PRE- cabins. FILTERSFeatures techniques G2-G4Type: Laminar flow HEPA panel. 2Frame: Extruded and anodised aluminium profile.Material: Glass microfiber filter paper. PAINTINGSSeparators: Hot melt beads. BOOTHSSealant: Polyurethane.Protective grid: Steel grid painted on both sides in white Dimensions 3epoxy.Joint: Gel PRODUCTSMPPS Efficiency: 99,995% and 99,9995% CONFORClass EN 1822: H14 and U15 M5-F9Recommended Final Pressure Loss: 600 Pa.Temperature: 80ºC in continuous service. 4Advantages Certification EPA/HEPA /ULPA- The new gek seal prevents those leaks that occur in neopreneor liquid filters, which lose elasticity over 5 time and so copromise the sealing capacity of terminal diffu- HIGHsers and filters. TEMPERA-- Grid protection at the air inlet and outlet to avoid breakageson the filter surface. TURE- 100% scanned, in accordance with regulations EN 1822-4.- DOUBLE LABELLING ATTACHED. 6 EQUIP- MENTS 7 MOTORS AND TURBINESGel Seal detail 8 ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 103 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- References TION Reference Model Dimensions Efficiency Class Filtering Rated flow Rated Unit Weight UxP S1 HxLxP (MPPS 0.45 m/s flow vol. (kg) * * E%) EN 1882 Area (m2) (m3/h)/ Pa 0.45 m/s (m3) PRE- (m3/h)/ FILTERS Pa G2-G4 LVG121278H14 LVGEL 305x305x78 99,995 H14 2,66 150/120 225/185 0,007 2.5 1F2 LVG122478H14 LVGEL 610x305x78 99,995 H14 5,5 300/120 500/185 0,01 4 1FPAINTINGS LVG242478H14 LVGEL 610x610x78 99,995 H14 11 600/120 900/185 0,03 7 1F BOOTHS LVG244878H14 LVGEL 610x1220X78 99,995 H14 22 1200/120 2000/185 0,06 12 1 F3 LVG1224104H14 LVGEL 610x304x104 99.995 H14 7,15 300/90 750/240 0.02 6 1FPRODUCTS LVG2424104H14 LVGEL 610x610x104 99.995 H14 14,3 CONFOR LVG2448104H14 LVGEL 610x1220x104 99.995 H14 29 600/90 1500/240 0.04 12 1F M5-F9 1200/90 3000/240 0.08 25 1F4 LV121278H14 LVGEL 305x305x78 99,995 H14 2,5 125/120 225/185 0.007 1,4 1FEPA/HEPA /ULPA LV122478H14 LVGEL 610x305x78 99,995 H14 5,5 300/120 500/185 0.01 2,75 1 F5 LV181878H14 LVGEL 457x457x78 99,995 H14 6 340/120 450/185 0.02 3,10 1 F HIGH LV242478H14 LVGEL 610x610x78 99,995 H14 11 600/120 900/185 0.03 5,5 1 FTEMPERA- LV243678H14 LVGEL 610x915x78 99,995 H14 16,5 900/120 1500/185 0.04 8,25 1 F TURE LV244878H14 LVGEL 610x1220x104 99,995 H14 22 1200/120 2000/185 0.06 11 1 F6 LV1224104H14 LVGEL 610x305x104 99,995 H14 71,5 300/90 750/240 0,02 6 1F EQUIP- LV2424104H14 LVGEL 610x610x104 99,995 H14 14,3 MENTS LV2448104H14 LVGEL 610x1220x104 99,995 H14 29 600/90 1500/240 0,04 12 1F7 120/90 3000/240 0,08 25 1F MOTORS LV121278U15 LVGEL 305x305x78 99,9995 U15 2,5 125/150 225/230 0,007 1,4 1F AND LV122478U15 LVGEL 610x305x78 99,9995 U15 5,5 300/150 450/230 0,01 2,75 1 FTURBINES LV181878U15 LVGEL 457x457x78 99,9995 U15 6 340/150 500/230 0,02 3,10 1 F8 LV242478U15 LVGEL 610x610x78 99,9995 U15 11 600/150 900/230 0,03 5,5 1 F ADSOR- TION AND LV243678U15 LVGEL 610x945x78 99,9995 U15 16,5 900/150 1500/230 0,04 8,25 1 F DESODO- RIZATION LV244878U15 LVGEL 610x1220x78 99,9995 U15 22 1200/150 200/230 0,06 11 1F9 LV1224104U15 LVGEL 610x305x104 99,9995 U15 7,15 300/110 750/300 0,02 6 1F INTER- LV2424104U15 LVGEL 610x610x104 99,9995 U15 14,3 600/110 1500/300 0,04 12 1F NATONALNORMATI- LV2448104U15 LVGEL 610x1220x104 99,9995 U15 29 1200/110 3000/300 0,08 25 1 F VE UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock Venfilter Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 104
EPA/HEPA/ULPA 0Laminarven GV INFORMA- TIONAbsolute Filtration / Clean RoomsClass: E, H and U 1Terminal or air return filtration in clean rooms and lami- Dimensions PRE-nar flow cabins. FILTERSFeatures techniques G2-G4Type: Laminar Flow HEPA Panel. 2Frame: Galvanized.Filtering Element: Glass microfibre paper. PAINTINGSSeparators: Thermoplastic glue beads. BOOTHSSealant: Polyurethane.Joint: Gasket with plane profile of neoprene. 3MPPS Efficiency : 85%, 99.95% and 99.995%Class EN 1822: E10, H13 and H14 PRODUCTSRecommended Final Pressure Loss: 600 Pa. CONFORTemperature: 80ºC in continuous service. M5-F9 4Advantages Certification EPA/HEPA /ULPA- 100% scanned in accordance with regulation EN 1822-4.- DOUBLE LABELLING ATTECHED. 5References HIGH TEMPERA-Reference Model Dimensions Efficiency Class Filtering Rated flow (m3/h Unit Vol. Weight UxP* Stock HxLxP (MPPS EN Area / Pa) (m3) (Kg) * TURE E%) 1822 (m2) 1LVGV121278H13 LVGV78 305x305x78 125/95-250/180 0,007 1.4 1 F 6LVGV122478H13 LVGV78 610x305x78 99,95 H13 2,5 300/95-540/180 0,01 2,75 1 FLVGV181878H13 LVGV78 457x457x78 99,95 H13 5,5 340/95-600/180 0,02 3.10 1 F EQUIP-LVGV222278H13 LVGV78 575x575x78 99,95 H13 6 535/95-970/180 0,03 1 F MENTSLVGV242478H13 LVGV78 610x610x78 99,95 H13 9,9 600/95-1100/180 0,03 5 1 FLVGV121278H14 LVGV78 305x305x78 99,95 H13 11 125/120-250/230 0,007 5.5 1 F 7LVGV122478H14 LVGV78 610x305x78 99,995 H14 2,5 300/120-540/230 0,01 1.4 1 FLVGV181878H14 LVGV78 457x457x78 99,995 H14 5,5 340/120-600/230 0,02 2,75 1 F MOTORSLVGV222278H14 LVGV78 575x575x78 99,995 H14 6 535/120-970/230 0,03 3.10 1 F ANDLVGV242478H14 LVGV78 610x610x78 99,995 H14 9,9 600/120-1100/230 0,03 5 F 99,995 H14 11 5.5 TURBINES UxP (*) Stock 8 Units per box F: Manufacturer, S: Stock, SL: Limited Stock ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 105 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- Laminarven DM TION Absolute Filtration / Clean Rooms1 Class: E, H and U PRE- Terminal or air return filtration in clean rooms and lami- Dimensions FILTERS nar flow cabins. G2-G4 Features techniques2 Type: Laminar Flow HEPA Panel. Frame: DM Wood.PAINTINGS Filtering Element: Glass microfibre paper. BOOTHS Separators: Thermoplastic glue beads. Sealant: Polyurethane.3 Joint: Gasket with plane profile of neoprene. MPPS Efficiency: 85%, 99.95% and 99.995%PRODUCTS Class EN 1822: E10, H13 and H14 CONFOR Recommended Final Pressure Loss: 600 Pa. M5-F9 Temperature: 80ºC in continuous service.4EPA/HEPA Advantages Certification /ULPA - 100% scanned in ccordance with regulation EN 1822-4.5 - DOUBLE LABELLING ATTACHED. HIGH ReferencesTEMPERA- Reference Model Dimensions Efficiency Class Filtering Rated flow (m3/h Unit Vol. Weight UxP* Stock TURE HxLxP (MPPS EN Area / Pa) * E%) 1822 (m2) (m3) (Kg) 16 1 F LVDM121278H13 LVDM78 305x305x78 99,95 H13 2,5 125/95-250/180 0,007 1.4 1 F EQUIP- LVDM122478H13 LVDM78 610x305x78 99,95 H13 5,5 300/95-540/180 0,01 2,75 1 F MENTS LVDM181878H13 LVDM78 457x457x78 99,95 H13 6 340/95-600/180 0,02 3.10 1 F LVDM222278H13 LVDM78 575x575x78 99,95 H13 9,9 535/95-970/180 0,03 1 F7 LVDM242478H13 LVDM78 610x610x78 99,95 H13 11 600/95-1100/180 0,03 5 1 F LVDM121278H14 LVDM78 305x305x78 99,995 H14 2,5 125/120-250/230 0,007 5.5 1 F MOTORS LVDM122478H14 LVDM78 610x305x78 99,995 H14 5,5 300/120-540/230 0,01 1.4 1 F AND LVDM181878H14 LVDM78 457x457x78 99,995 H14 6 340/120-600/230 0,02 2,75 1 F LVDM222278H14 LVDM78 575x575x78 99,995 H14 9,9 535/120-970/230 0,03 3.10 FTURBINES LVDM242478H14 LVDM78 610x610x78 99,995 H14 11 600/120-1100/230 0,03 5 5.58 UxP (*) Stock ADSOR- Units per box F: Manufacturer, S: Stock, SL: Limited StockTION AND DESODO-RIZATION9 INTER- 106 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comNORMATI- Fax +34 937 862 493 VE
EPA/HEPA/ULPA 0Terminal block INFORMA-without regulation TIONAbsolute Filtration / Clean Rooms 1Class: H and U PRE- FILTERS G2-G4Terminal Block without regulation for terminal filtration 2or air return in clean rooms.Features techniques Dimensions PAINTINGS Certification BOOTHSType: HEPA/ULPA laminar flow Diffuser-Filter H14.Frame: Extruded and anodised aluminium profile. 3Filtering Element: Glass microfibre paper.Separators: Thermoplastic glue beads. PRODUCTSSealant: Polyurethane. CONFORProtective grille: Steel grille at the outlet, painted with white M5-F9epoxy.Joint: Self-adhesive Neoprene Seal. 4Attachment: Ext. O-neck 200, 250 and 315 mm. (according tomodel). EPA/HEPAMPPS Efficiency: 99.995% % and 99,9995% /ULPAClass EN 1822: H14 and U15Recommended Final Pressure Loss: 600 Pa. 5Temperature: 80ºC in continuous service.Advantages HIGH TEMPERA-- Low weight, reduced depth monoblock filtering.- These filters are assembled and installed with a one-pice semi-circulare polyurethane seal at the outlet in TURE order to prevent particle migration or leakage between the filter and the racks or the frames of the installation 6structure. EQUIP- MENTS 7Photo detail joint MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 107 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- References TION Reference Model Dimensions Efficiency Class Rated flow Neck Unit Vol. Weight UxP Stock1 HxLxP (MPPS E EN 1822 (m3/h / Pa) (m3) (Kg) * * 200 PRE- BTSR122405/200H14 BTSR 305x610x125 %) H14 300/140 250 0,03 3.5 1 F FILTERS BTSR242405/250H14 BTSR 610x610x125 H14 600/140 250 0,05 7 1 F BTSR243605/250H14 BTSR 610x915x125 99,995% H14 900/140 250 0,07 10 1 F G2-G4 BTSR244805/250H14 BTSR 610x1220x125 99,995% H14 1200/140 200 0,10 13 1 F BTSR121206/200H14 BTSR 305x305x152 99,995% H14 150/140 200 0,02 2 1 F2 BTSR122406/250H14 BTSR 305x610x152 99,995% H14 300/140 250 0,03 3.5 1 F BTSR181806/250H14 BTSR 457x457x152 99,995% H14 340/140 250 0,03 6 1 FPAINTINGS BTSR242406/250H14 BTSR 610x610x152 99,995% H14 600/140 250 0,06 7 1 F BOOTHS BTSR243606/250H14 BTSR 610x915x152 99,995% H14 900/140 250 0,09 10 1 F BTSR244806/250H14 BTSR 610x1220x152 99,995% H14 1200/140 150 0,12 13 1 F3 BTSR111106/200H14 BTSR 300x300x152 99,995% H14 150/140 200 0,02 2 1 F BTSR112306/200H14 BTSR 300x600x152 99,995% H14 300/140 250 0,03 3.5 1 FPRODUCTS BTSR232306/250H14 BTSR 600x600x152 99,995% H14 600/140 250 0,06 7 1 F CONFOR BTSR233506/250H14 BTSR 600x900x152 99,995% H14 900/140 250 0,09 10 1 F M5-F9 BTSR234706/250H14 BTSR 600x1200x152 99,995% H14 1200/140 0,12 13 1 F 99,995% 3154 99,995% 315 F 315 FEPA/HEPA BTSR242406/315H14 BTSR 610x610x152 99,995% H14 600/140 0,06 8 1 F /ULPA 200 0,09 12 1 BTSR243606/315H14 BTSR 610x915x152 99,995% H14 900/140 250 0,12 16 1 F5 250 F BTSR244806/315H14 BTSR 610x1220x152 99,995% H14 1200/140 F HIGHTEMPERA- BTSR122406/200U15 BTSR 305x610x152 99,9995% U15 300/170 0,03 3,5 1 BTSR242406/250U15 BTSR 610x610x152 99,9995% U15 600/170 0,06 7 1 TURE BTSR244806/250U15 BTSR 610x1220x152 99,9995% U15 1200/170 0,12 13 16 UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- 108 Venfilter [email protected] AND Tel +34 937 862 607 www.venfilter.comDESODO- Fax +34 937 862 493RIZATION9 INTER-NATONALNORMATI- VE
EPA/HEPA/ULPA 0Terminal block INFORMA-with regulation TIONAbsolute Filtration / Clean Rooms 1Class: H and U PRE- FILTERS G2-G4Terminal Block with regulation for terminal filtration or Dimensions 2air return in clean rooms. Certification PAINTINGSFeatures techniques BOOTHSType: HEPA/ULPA laminar flow Diffuser-Filter H14. 3Frame: Extruded and anodised aluminium profile.Filtering Element: Glass microfibre paper. PRODUCTSSeparators: Thermoplastic glue beads. CONFORSealant: Polyurethane. M5-F9Protective grille: Steel grille at the outlet painted with whiteepoxy. 4Joint: Self-adhesive Neoprene Seal.Attachment: Ext. O-neck 200, 250 and 315 mm. (according to EPA/HEPAmodel). /ULPAMPPS Efficiency: 99.995% and 99.9995%Class EN 1822: H14 and U15 5Recommended Final Pressure Loss: 600 Pa.Temperature: 80ºC in continuous service.Advantages HIGH TEMPERA-- Low weigth, reduced depth monoblock filtering. - These filters are assembled and installed with a one-piece semi-circular polyurethane TURE seal at the outlet in order prevent particle migration or leakage between the filter and the racks or the frames of the installation structure. 6- Flow-regulation with load - A diffuser plate can be ad- EQUIP-loss and room contamina- justed from the regulation MENTStion level testing. system in order to distribui- te the air in the plenum en- 7 vely over the filter surface. MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 109 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- References Model Dimensions Efficiency Class Rated flow Neck Unit Vol. Weight UxP Stock TION HxLxP (MPPS E EN 1822 (m3/h / Pa) Inlet (m3) (Kg) * * Reference1 305x610x125 %) H14 300/140 200 610x610x125 H14 600/140 250 PRE- BTCR122405/200H14 BTCR 610x915x125 99,995% H14 900/140 250 0,03 4 1 F FILTERS BTCR242405/250H14 BTCR 610x1220x125 99,995% H14 1200/140 250 0,05 8 1 F BTCR243605/250H14 BTCR 305x610x152 99,995% H14 300/140 200 0,07 12 1 F G2-G4 BTCR244805/250H14 BTCR 457x457x152 99,995% H14 340/140 250 0,10 16 1 F BTCR122406/200H14 BTCR 610x610x152 99,995% H14 600/140 250 0,03 4 1 F2 BTCR181806/250H14 BTCR 610x915x152 99,995% H14 900/140 250 0,03 7 1 F BTCR242406/250H14 BTCR 610x1220x152 99,995% H14 1200/140 250 0,06 8 2 FPAINTINGS BTCR243606/250H14 BTCR 300x600x152 99,995% H14 300/140 200 0,09 12 1 F BOOTHS BTCR244806/250H14 BTCR 600x600x152 99,995% H14 600/140 250 0,12 16 1 F BTCR112306/200H14 BTCR 600x900x152 99,995% H14 900/140 250 0,03 4 1 F3 BTCR232306/250H14 BTCR 600x1200x152 99,995% H14 1200/140 250 0,06 8 1 F BTCR233506/250H14 BTCR 99,995% 0,09 12 1 FPRODUCTS BTCR234706/250H14 BTCR 610x610x152 99,995% 315 0,12 16 1 F CONFOR 610x915x152 315 M5-F9 BTCR242406/315H14 BTCR 610x1220x152 99,995% H14 600/140 315 0,06 8 1 F BTCR243606/315H14 BTCR 0,09 12 1 F4 BTCR244806/315H14 BTCR 99,995% H14 900/140 200 0,12 16 1 F 250 99,995% H14 1200/140 250EPA/HEPA BTCR122406/200U15 BTCR 305x610x152 99,9995% U15 300/170 0,03 4 1 F /ULPA BTCR242406/250U15 BTCR 610x610x152 99,9995% U15 600/170 0,06 8 1 F BTCR244806/250U15 BTCR 610x1220x152 99,9995% U15 1200/170 0,12 16 1 F5 UxP (*) Stock HIGH Units per box F: Manufacturer, S: Stock, SL: Limited StockTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- 110 Venfilter [email protected] AND Tel +34 937 862 607 www.venfilter.comDESODO- Fax +34 937 862 493RIZATION9 INTER-NATONALNORMATI- VE
EPA/HEPA/ULPA 0Microven (MDF) INFORMA- TIONFunction of pressure drop vs. flow rateMCDMP-150 1MCDMP-292 PRE- FILTERSVenfilter [email protected] +34 937 862 607 www.venfilter.com G2-G4Fax +34 937 862 493 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 111 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- Graphic TION Microven (Galvanised)1 Function of pressure drop vs. flow rate PRE- MCGVP-150 FILTERS G2-G42PAINTINGS BOOTHS3 MCGVP-292 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 112 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0 Astroven (MDF) INFORMA- TION Function of pressure drop vs. flow rate AVDMPH13-150 1 AVDMPH13-292 PRE- FILTERSVenfilter [email protected] +34 937 862 607 www.venfilter.com G2-G4Fax +34 937 862 493 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 113 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- AVDMPPH13-150 TION1 PRE- FILTERS G2-G42PAINTINGS BOOTHS3 AVDMPPH13-292 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 114 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0 AVDMPH14-150/292 INFORMA- TION AVDMPPH14-150/292 1Venfilter [email protected] +34 937 862 607 www.venfilter.com PRE-Fax +34 937 862 493 FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 115 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- Astroven (Galvanised) TION Function of pressure drop vs. flow rate1 AVGVPH13-150 PRE- FILTERS G2-G42PAINTINGS BOOTHS3 AVGVPH13-292 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 116 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0 AVGVPPH13-150 INFORMA- TION AVGVPPH13-292 1Venfilter [email protected] +34 937 862 607 www.venfilter.com PRE-Fax +34 937 862 493 FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 117 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- AVGVPH14-150/292 TION1 PRE- FILTERS G2-G42PAINTINGS BOOTHS3 AVGVPPH14-150/292 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 118 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0Poliven INFORMA- TION Function of pressure drop vs. flow rate PVGV/PV-E10 1 PVGV/PV-H13/H14 PRE- FILTERSVenfilter [email protected] +34 937 862 607 www.venfilter.com G2-G4Fax +34 937 862 493 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL 119 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- Laminarven 66 mm TION Function of pressure drop vs. flow rate1 LV-66 PRE- LV66 FILTERS G2-G42PAINTINGS BOOTHS3 Laminarven Plus 90/110 mm Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS Function of pressure drop vs. flow rate Fax +34 937 862 493 CONFOR LV-90/110-H14 M5-F9 1204EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0 Function of pressure drop vs. flow rate INFORMA- LV-90/110-U15 TIONLaminarven 78 mm 1 Function of pressure drop vs. flow rate PRE- LV-78 H13 FILTERS LV-78 H13 G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 121 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 EPA/HEPA/ULPAINFORMA- Laminarven Gel TION Function of pressure drop vs. flow rate1 LVG-H14 PRE- FILTERS G2-G42PAINTINGS BOOTHS3 LVG-U15 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 122 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
EPA/HEPA/ULPA 0Laminarven DM INFORMA- TIONFunction of pressure drop vs. flow rateLVDM-H13 1 LVDM78 H13 PRE- FILTERSLaminarven GV G2-G4Function of pressure drop vs. flow rateLVGV-H13 2 LVGV78 H13 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 123 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 High temperature DimensionsINFORMA- HT-1000 TION High Temperature Filters1 Air suction and expulsion in painting cabins up to 300ºC PRE- FILTERS Features techniques G2-G4 Type: Flat fibreglass panel filter for high temperatures. Frame: Galvanised Steel with protective fabric on both sides2 or expanded Aluminium. Media: Fibreglass with a high efficiency interfacing in the airPAINTINGS outlet. BOOTHS Average yield % (Em): 93% Average efficiency % (Am): 98%3 Class EN 779: G4 and M5 Recommended Final Pressure Loss: 250 Pa.PRODUCTS Temperature: G4 300ºC, M5 200ºC CONFOR M5-F9 References4 Reference Dimensions Average Efficiency Class Rated flow Chamber Weight UxP Stock HxLxP % (Am) EN 779 (m3/h / Pa) Vol. (Kg) * *EPA/HEPA (m3) /ULPA HT202014 480x480x14 93% G4 1000/70 0.25 25 S HT242414 610x610x14 93% G4 1600/70 0.11 0.4 25 F5 HT-CM202018 490x490x18 93% G4 1000/70 0.13 S HT-CM242418 610x610x18 93% G4 1600/70 F HIGHTEMPERA- HT202014F5 480x480x14 98% M5 350/50 F HT-CM202018F5 490x490x18 98% M5 350/50 F TURE UxP (*) Stock6 Units per box F: Manufacturer, S: Stock, SL: Limited Stock EQUIP- Venfilter MENTS Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 124 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
High temperature 0Quebraven Galvanised Dimensions INFORMA-High Temperature TIONPre-filtration Class: G 1Metallic pre-filter (Galvanised) for the retention of coar- PRE-ser particles in industrial installations and processes with FILTERSa large airflow, high temperatures with reduced spatialarea. Silicone free G2-G4Features techniques 2Type: Disposable filter with an uneven surface, zigzag plea- PAINTINGSted, with fiber glassl and a grille on both sides. BOOTHSFrame: Galvanised Steel.Grille: Galvanised metal on one side. 3Media: Fiber glass.Class EN 779: G4 PRODUCTSRecommended Final Pressure Loss: 250 Pa. CONFORTemperature: 350ºC M5-F9 4 Certification EPA/HEPA /ULPA 5 HIGH TEMPERA- TUREReferences 6Reference Dimensions Average Class Rated Chamber Weight UxP Stock ME Stock* EQUIP- HxLxP Efficiency EN 779 flow Vol. (Kg) * * % MENTS % (Am) (m3/h / (m3) 35 SL G4 Pa) 0.03 3.5 F 7QMHT242404G4 QMHT 592X592X96 110 2.2 0.028 3.3 35 FQMHT202404G4 QMHT 492x592x96 G4 3400 1.9 0.023 3.2 F MOTORSQMHT202004G4 QMHT 492x492x96 2800 1.55 0.015 1.75 SL ANDQMHT122404G4 QMHT 287x592x96 2350 1.1 0.02 2.3 FQMHT242402G4 QMHT 592x592x48 1700 0.014 1.7 F TURBINESQMHT202402G4 QMHT 492x592x48 2000 100 1.6 0.012 1.6 FQMHT202002G4 QMHT 492x492x48 1650 1.35 0.01 1.2 8QMHT122402G4 QMHT 287x592x48 1375 1.1 1000 0.8 ADSOR- TION AND UxP (*) Stock DESODO-Units per box F: Manufacturer, S: Stock, SL: Limited Stock RIZATION 9 Venfilter [email protected] 125 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 High temperatureINFORMA- Varivent HT TION High Temperature Filters1 Filtration in cabins & Painting Ovens PRE- FILTERS Features techniques Dimensions VVHT G2-G4 Type: Compact filter with High Efficiency for high temperatu- VVHTP res.2 Frame: Galvanised Steel. Filtering Element: Fibreglass Paper.PAINTINGS Separators: Corrugated Aluminium or Fiberglass Strip BOOTHS Sealant: Fiberglass Clamp or flange: Galvanised Steel.3 Joint: Fiberglass with exterior covering or ceramic. Average efficiency % (Am): 60 Em 80%, 80 Em 90% & 90 EmPRODUCTS 95%. CONFOR Class EN 779: M6, F7 y F8 M5-F9 Recommended Final Pressure Loss: 450 Pa. Temperature: Max. in service 250ºC, Max. in beaks 350ºC.4 VVHTP: With flange or clamp. VVHT: Without flange or clamp.EPA/HEPA /ULPA Advantages Certification5 - Silicone Free HIGH ReferencesTEMPERA- Reference Dimensions Average Class Rated Chamber Weight UxP Stock ME Clas. Cons. UxP S. TURE HxLxP Efficiency % (Am) EN flow Vol. (Kg) * * *% Energ. Energ. * *6 779 (m3/h / (m3) Kwh/ EQUIP- MENTS Pa) Año7 VVHTP242412F8 VVHTP 592x592x292 F8 3400 150 12 0.11 8.2 71 D 2550 1S VVHTP202412F8 VVHTP 490x592x292 2750 9 0.09 7.8 D 1F MOTORS AND VVHTP122412F8 VVHTP 287x592x292 1700 6 0.05 4.2 D 1F VVHTP122406F8 VVHTP 287x592x150 850 3 0.03 2.8TURBINES VVHTP242412F6 VVHTP 592x592x292 3400 12 0.11 8.2 D 1F VVHTP202412F6 VVHTP 490x592x292 2750 9 0.09 7.88 VVHTP122412F6 VVHTP 287x592x292 M6 1700 110 6 0.05 4.2 E 2000 1F VVHTP122406F6 VVHTP 287x592x150 850 3 0.03 2.8 ADSOR- E 1F TION AND DESODO- E 1F RIZATION E 1F9 UxP (*) Stock ME%: Minium Efficiency to EN779:2012 INTER- Units per box F: Manufacturer, S: Stock, SL: Limited Stock *Energy Consumption,KWh/year: Calculated according to NATONALNORMATI- 126 Eurovent Guideline 4/21 Clasificación Energética: Calculated according to VE Eurovent 4/21. Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
High temperature 0References INFORMA- TIONReference Dimensions Average Class Rated Chamber Weight UxP Stock ME* Clas. Cons. UxP S. HxLxP Efficiency EN flow Vol. (Kg) * * % Energ. Energ. ** 1 % (Am) 779 (m3/h / (m3) Kwh/ Pa) PRE- Año FILTERSVVHT242412F8 VVHT 610x610x292 F8 4250 160 14 0.11 11 71 1F G2-G4VVHT122412F8 VVHT 305x610x292 F8 2125 7 0.05 6 1FVVHT242478F8 VVHT 610X610x78 2000 1F 2VVHT243678F8 VVHT 610x915x78 M6 3000 120 7.5 0.09 4.4 69 1FVVHT183678F8 VVHT 457x915x78 M6 2250 11.25 0.06 6.5 1F PAINTINGSVVHT191978F8 VVHT 480x480x78 1240 8.5 0.12 4.9 1F BOOTHSVVHT242455F8 VVHT 610x610x55 2000 4.6 0.06 2.7 1FVVHT242412F6 VVHT 610x610x292 4250 7.5 0.06 3.9 1F 3VVHT122412F6 VVHT 305x610x292 2125 1FVVHT242478F6 VVHT 610x610x78 2500 130 14 0.11 11 n.a. 1F PRODUCTSVVHT243678F6 VVHT 610x915x78 3750 7 0.05 6 1F CONFORVVHT183678F6 VVHT 457x915x78 2800 1F M5-F9VVHT191978F6 VVHT 480x480x78 1550 120 7.5 0.09 4.4 n.a. 1FVVHT242455F6 VVHT 610x610x55 2500 11.25 0.06 6.5 1F 4 8.5 0.12 4.9 4.6 0.06 2.7 7.5 0.06 3.9 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 127 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 High temperature Dimensions [email protected] Certification www.venfilter.comINFORMA- Multiven HT 120º TION Venfilter Air Treatment Tel +34 937 862 6071 Class: M and F Fax +34 937 862 493 PRE- Intake, discharge and recirculation in ventilation systems FILTERS requiring HIGH TEMPERATURE: in air conditioning equi- pment (air conditioning units, ventilation chambers, etc.), G2-G4 air conditioning systems (hospitals, laboratories, museu- ms, airports, etc.), industrial processes (the pharmaceu-2 tical food, optics, microelectronics, veterinary medicine and chemical industries and for surface treatments) andPAINTINGS as a pre-filter for Hepa and Ulpa filters. BOOTHS Features techniques3 Type: Compact filter - polyhedral rigid bag.PRODUCTS Frame: Polycarbonate. CONFOR Filter Component: Fibreglass paper. M5-F9 Separators: High temperature glue beads. Sealant: Polyurethane.4 Average Efficiency % (Em): 60% ‹ Em ‹ 80%, 80% ‹ Em ‹ 90%, 90% ‹ Em ‹ 95% & 95% ‹ Em.EPA/HEPA Class EN 779: M6, F7, F8 and F9 /ULPA Recommended Final Pressure Drop: 600 Pa. Temperature: 120-150 ºC continuous service.5 Advantages HIGHTEMPERA- - High Capacity of dust retention. - Temperature: 350 ° C continuous service. TURE 1286 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
High temperature 0References INFORMA- TION Reference Model Dimensions Class EN Rated Flow Initial PA. Area V. Unit Weight ME HxLxP 779 (m3/h) 155 (m2) M3 KG. % 1Stock*MVHT120242412F9 MVHT F9 125 80MVHT120202412F9 MVHT 592x592x292 4250 115 0.12 5 1 F PRE-MVHT120122412F9 MVHT 492x592x292 F8 3500 100 0,09 4 70 1 FILTERSMVHT120242412F8 MVHT 292x592x292 2125 0,06 3 1MVHT120202412F8 MVHT 592x592x292 F7 4250 0,12 5 54 1 F G2-G4MVHT120122412F8 MVHT 492x592x292 3500 0,09 4 1 FMVHT120242412F7 MVHT 292x592x292 M6 2125 0,06 3 1MVHT120202412F7 MVHT 592x592x292 4250 0,12 5 1 2FMVHT120122412F7 MVHT 492x592x292 3500 0,09 4 1MVHT120242412F6 MVHT 292x592x292 2125 0,06 3 1 FMVHT120202412F6 MVHT 592x592x292 4250 0,12 5 1 FMVHT120122412F6 MVHT 492x592x292 3500 0,09 4 1 F PAINTINGS 292x592x292 2125 0,06 3 1 F BOOTHS F UxP (*) Stock ME%: Minium Efficiency to EN779:2012Units per box F: Manufacturer, S: Stock, SL: Limited Stock 3F F F PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 129 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 High temperature DimensionsINFORMA- Multiven HT 350ºC TION Air Treatment1 Class: M and F PRE- Intake, discharge and recirculation in ventilation systems FILTERS requiring HIGH TEMPERATURE: in air conditioning equip- ment (air conditioning units, ventilation chambers, etc.), air G2-G4 conditioning systems (hospitals, laboratories, museums, airports, etc.), industrial processes (the pharmaceutical food,2 optics, microelectronics, veterinary medicine and chemical industries and for surface treatments) and as a pre-filter forPAINTINGS Hepa and Ulpa filters. BOOTHS Features techniques3 Type: Compact filter - polyhedral rigid bag.PRODUCTS Frame: Polycarbonate. CONFOR Filter Component: Fibreglass paper. M5-F9 Separators: High temperature glue beads. Sealant: Polyurethane.4 Average Efficiency % (Em): 60% ≤ Em < 80%, 90% ≤ Em < 95% and 95% ≤ Em.EPA/HEPA Class EN 779: M6, F8 and F9 /ULPA Recommended Final Pressure Drop: 450 Pa. Temperature: 350 ºC continuous service.5 Certification HIGHTEMPERA- Advantages TURE - Temperature: 350 ° C continuous service.6 References EQUIP- Reference Model Dimensions Class Rated Initial Unit Vol. ME* Class. Cons. UxP S MENTS HxLxP EN779 flow PA (m3) % Energ. Energ. * * (m3/h)7 140 0.12 Kwh/ 0,09 year MOTORS 97 0,06 AND MVGVHT350242412F8 MVGVHT350 592x592x292 F8 3400 0,12 73 C 1830 1F MVGVHT350202412F8 MVGVHT350 492x592x292 M6 2800 0,09TURBINES MVGVHT350122412F8 MVGVHT350 287x592x292 1700 0,06 C 1F MVGVHT350242412F6 MVGVHT350 592x592x292 34008 MVGVHT350202412F6 MVGVHT350 492x592x292 2800 C 1F MVGVHT350122412F6 MVGVHT350 287x592x292 1700 ADSOR- 19 E 1426 1F TION AND DESODO- E 1F RIZATION E 1F9 UxP (*) Stock ME%: Minium Efficiency to EN779:2012 INTER- Units per box F: Manufacturer, S: Stock, SL: Limited Stock *Energy Consumption,KWh/year: Calculated according to NATONALNORMATI- Eurovent Guideline 4/21 Clasificación Energética: Calculated according to VE Eurovent 4/21. 130 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
High temperature 0Astroven HT 250ºC INFORMA- TIONHigh Temperature Filters 1For ultraclean processes at high temperatures. Dimensions PRE- FILTERSFeatures techniques G2-G4Type: High Temperature absolute filter.Frame: Galvanised Steel. 2Filtering Element: Glass microfibre paper.Separators: Corrugated Aluminium. PAINTINGSSealant: Silicone for high temperature. BOOTHSJoint: Silicone.MPPS Efficiency: 99.95% % 3Class EN 1822: H13Recommended Final Pressure Loss: 450 Pa. PRODUCTSTemperature: Up to 250ºC in continuous service. CONFORRATED FLOWS (M3/H.) AND EFFICIENCIES (CLASS EN 1822) M5-F9AT A TEMPERATURE OF 25ºC. 4References EPA/HEPA /ULPAReferences Model Dimensions Efficiency Class Filtering Rated Unit vol. Weight UxP Stock HxLxP (MPPS E EN1822 Area flow (m3) 5 (m2) (m3/h / (kg) * * %) H13 Pa) 0.02 HIGH H13 2,48 0.03 TEMPERA-AVGVHT250121206H13 AVHT250 305x305x150 99.95% H13 5,16 250/250 0.072 41 FAVGVHT250122406H13 AVHT250 610x305x150 99,95% H13 5,97 540/250 0.072 61 F TUREAVGVHT250181806H13 AVHT250 457x457x150 99,95% H13 11 600/250 0,1 7,3 1 FAVGVHT250242406H13 AVHT250 610x610x150 99,95% 13,7 1180/250 9,5 1 F 6AVGVHT250243006H13 AVHT250 762x610x150 99,95% 1500/250 10,6 1 F EQUIP-AVGVHT250121211H13 AVHT250 305x305x292 99,95% H13 5,1 410/250 0,03 5,1 1 F MENTSAVGVHT250122411H13 AVHT250 610x305x292 99,95% H13 9,3 1 FAVGVHT250181811H13 AVHT250 457x457x292 99,95% H13 11 1000/250 0.063 10,5 1 F 7AVGVHT250242411H13 AVHT250 610x610x292 99,95% H13 16,5 1 FAVGVHT250243011H13 AVHT250 762x610x292 99,95% H13 12,8 1030/250 0,13 21,5 1 F MOTORS AND 22,5 2000/250 0,13 TURBINES 28,2 2500/250 0,16 UxP (*) Stock 8Units per box F: Manufacturer, S: Stock, SL: Limited Stock ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 131 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 High temperatureINFORMA- Poliven HT 150ºC TION High Temperature Filters1 The HEPA absolute filters are used for filtration of incoming, PRE- outgoing and recirculation air in ventilation systems such as: FILTERS Incoming Air: Clean Rooms, Operating Theatres, Laboratories, etc. Industrial Processes: Microelectronics, food industry, optics, G2-G4 pharmaceutical industry, fine chemistry, etc. Treatment of Dangerous substances: Asbestos, Metal dust, Bacteria, Viruses,2 Radioactive Particles.PAINTINGS Features techniques Dimensions BOOTHS Type: Compact Polyhedral Absolute Filter with Very High3 Efficiency and Large Flow. Frame: Galvanised Steel with handlePRODUCTS Filtering Element: Glass microfibre paper. CONFOR Separators: Glue beads Higt Temperature. M5-F9 Sealant: Polyurethane. Joint: Bicomponent polyurethane liquid system. (Semi-circu-4 lar expanded polyurethane) MPPS efficiency: 85%, 99.95% and 99.995%EPA/HEPA Class EN 1822: E10, H13 and H14 /ULPA Recommended Final Pressure Loss: 600 Pa. Temperature: 120-145 ºC in continuous service.5 Advantages HIGHTEMPERA- - High rated flow for a low pressure loss. - Filters totally interchangeable with the minipleat aluminium TURE separator filters which have galvanised steel or wooden frames.6 References EQUIP- Reference Model Dimensions Efficiency Class Filtering Rated Unit Weight UxP Stock MENTS HxLxP (MPPS E EN1822 Area flow Vol. (m2) (m3/h / (m3) (kg) * *7 %) Pa) 16 0,05 MOTORS PVGVHT120122412.4H13 PVGVHT120 610x305x292 99,95% H13 32 1700/250 0,12 14 1 F AND PVGVHT120242412.8H13 PVGVHT120 610x610x292 99,95% H13 40 3400/250 0,12 21 1 F PVGVHT120242412.10H13 PVGVHT120 610x610x292 99,95% H13 16 4000/280 0,05 23 1 FTURBINES PVGVHT120122412.4H14 PVGVHT120 610x305x292 99,995% H14 40 1200/280 0,12 14 1 F PVGVHT120242412.10H14 PVGVHT120 610x610x292 99,995% H14 3000/280 23 1 F8 UxP (*) Stock ADSOR- Units per box F: Manufacturer, S: Stock, SL: Limited Stock TION AND DESODO- Venfilter RIZATION Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 132 INTER- NATONALNORMATI- VE
High temperature 0Graphic INFORMA- TIONHT-1000 1 Function of pressure drop vs. flow rateHT PRE- FILTERSVariven HT G2-G4 Function of pressure drop vs. flow rateVVHTP 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 133 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 High temperature Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comINFORMA- Variven HT Fax +34 937 862 493 TION Function of pressure drop vs. flow rate1 VVHT PRE- 134 FILTERS G2-G42PAINTINGS BOOTHS3PRODUCTS CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0Racks for INFORMA-pre-filters TIONFitting elements 1Modular frames for flat filters with a Medium and High PRE-Efficiency flange. FILTERSFeatures techniques G2-G4Type: Universal Frame for front fitting. 2Frame: Galvanised Steel and in Stainless Steel.Joint: Neoprene PAINTINGSFitting of filter: 4 spring clamps. BOOTHSAdvantages Dimensions 3- Structures adaptable to any installation. PRODUCTS- Filter assembly includes a polyurethane seal and four CONFORsprings to retain the filter and prevent leaks or particle mi- M5-F9gration.- Interconnection perforations for the securing or connection 4of racks. EPA/HEPA /ULPA 5References HIGH TEMPERA- TURE Reference Model Dimensions For Filters Unit Vol. Weight (Kg) UxP Stock Stock 6 LxHxP LxH (m3) * * *BTRM121203 BTRM EQUIP-BTRM121204 BTRM 305x305x75 287/290x287/290 25 o 25+25 0,007 0,53 14 F MENTSBTRM122403 BTRM 305x305x100 287/290x287/290 25+50 0,01 1,1 FBTRM122404 BTRM 305x610x75 287/290x592/595 0.014 8 SL 7BTRM122406 BTRM 305x610x100 287/290x592/595 25 o 25+25 0,019 1,45 9 SLBTRM202003 BTRM 305x610x140 287/290x592/595 25+50 0,022 7 F MOTORSBTRM202004 BTRM 508x508x75 490/495x490/495 0,02 2,1 6 F ANDBTRM202006 BTRM 508x508x100 490/495x490/495 25+100 0,03 FBTRM202404 BTRM 508x508x140 490/495x490/495 25 o 25+25 0,03 7 F TURBINESBTRM242403 BTRM 508x610x100 490/495x592/595 0,03 5 SLBTRM242404 BTRM 610x610x75 592/595x592/595 25+50 0,03 4 S 8BTRM242406 BTRM 610x610x100 592/595x592/595 25+100 0,04 SL 610x610x140 592/595x592/595 0.05 F ADSOR- 25+50 TION AND 25 o 25+25 DESODO- RIZATION 25+50 25+10 9 UxP (*) StockUnits per box F: Manufacturer, S: Stock, SL: Limited Stock Venfilter [email protected] 135 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 Equipments DimensionsINFORMA- Racks for Absolute TION filter1 Fitting elements PRE- Modular frames for High-efficiency filters and activated FILTERS carbon cells. G2-G4 Features techniques2 Type : Front-mounted Universal Frame. Frame: Galvanised steel.PAINTINGS Filter mounting : Fixed straps. BOOTHS Advantages3 - Structure adaptable to any installation.PRODUCTS - Filter assembly includes a one-piece, semi-circular polyu- CONFOR rethane seal and four non-movable angle pieces with tigh- M5-F9 tening screws and bolts for filter retention, in order to avoid leaks or particle migration.4 References Modelo Dimensiones Para Filtros V. Unitario StockEPA/HEPA LxHxP LxH (m3) * /ULPA Referencia BTRA BTRA 325x325x200 305x305x150 0,02 F5 BTRA121206 BTRA 325x325x330 305x305x292 0,04 F BTRA121212 BTRA 325x630x200 305x610x150 0,04 F HIGH BTRA122406 BTRA 325x630x330 305x610x292 0,07 STEMPERA- BTRA122412 BTRA 630x630x200 610x610x150 0,08 F BTRA242406 630x630x330 610x610x292 0,14 S TURE BTRA2424126 UxP (*) Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock EQUIP- MENTS Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com7 136 Fax +34 937 862 493 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0Metal Housing INFORMA-Filters of 66 and 78mm TIONFitting elements 1Terminal Diffuser for replaceable HEPA/ULPA filters, for PRE-air diffusion in Clean Rooms with turbulent and laminar FILTERSflow. G2-G4Features techniques 2Type: Diffuser Terminal unit for ceiling or wall installation for thefinal filtration of a Clean Room. PAINTINGSConstruction: Airtight welded electrogalvanised steel, white epoxy BOOTHSpaint (RAL 9010) and kiln dried.Air intake: At the top (HTMBS) or at the side (HTMBL), circular, 3with an attachment neck.Installation: Openings for attachment, which make for easy and PRODUCTSquick fitting. CONFORFilter attachment: In the lower part, against the smooth frame, one M5-F9single piece and held by attachment devices that exert a continuousand constant pressure. 4For filters: Filters of 69, 78 mm. in depth.We have a shallow model with upper air inlet (HTMBP) EPA/HEPA /ULPAAdvantages 5- Smmoth coating, facilitates cleaning the diffuser grid.- Internal centring devices for filters and fixed moutings for the positioning of the HIGH TEMPERA- filter inside the housing, preventing the filter from falling.- Easy filter assemble and replacement. TUREINSTALLATION:- Rigid construction design, allows quick and easy installation. 6- Installation in ceilings using side or upper entry.- Also equipped with four drilled brackets for suspended-type fitting. EQUIP- MENTS 7 MOTORS AND TURBINES 8Steel plenum Moutings for filter Probes for integrity Diffuser grids: Perforated ADSOR- retention testiong and differential or ratational, painted in TION AND pressure measurement white (RAL 9010) DESODO- RIZATION 9 Venfilter [email protected] 137 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 EquipmentsINFORMA- References TION HTMBL-Air intake at the side1 Dimensions (mm) For Filters Neck PRE- LxHxP (mm) inlet FILTERS Reference A A1 A2 B B1 B2 H (mm) UxP* Stock* G2-G4 HTMBL1212.2 367 264 319 367 264 319 290 305x305x66/78 150 1F HTMBL1224.2 672 569 624 367 264 319 290 305x610x66/78 150 1F2 HTMBL1818.2 519 416 471 519 416 471 340 457x457x66/78 200 1F HTMBL2121.2 597 494 549 597 494 549 340 535x535x66/78 200 1FPAINTINGS HTMBL2323.2 637 534 589 637 534 589 390 575x575x66/78 250 1F BOOTHS HTMBL2424.2 672 569 624 672 569 624 390 610x610x66/78 250 1F HTMBL2436.2 977 971 929 672 569 624 390 610X915x66/78 250 1F3 HTMBL2448.2 1282 1179 1234 672 569 624 390 1220x610x66/78 250 1FPRODUCTS HTMBS-Air intake at the top CONFOR M5-F9 Dimensions (mm) For Filters Neck LxHxP (mm) inlet4 Reference A A1 A2 B B1 B2 H (mm) UxP* Stock*EPA/HEPA HTMBS1212.2 367 264 319 367 264 319 340 305x305x66/78 150 1F /ULPA HTMBS1224.2 672 569 624 367 264 319 340 305x610x66/78 150 1F HTMBS1818.2 519 416 471 519 416 471 390 457x457x66/78 200 1F5 HTMBS2121.2 597 494 549 597 494 549 390 535x535x66/78 200 1F HTMBS2323.2 637 534 589 637 534 589 430 575x575x66/78 250 1F HIGH HTMBS2424.2 672 569 624 672 569 624 430 610x610x66/78 250 1FTEMPERA- HTMBS2436.2 977 874 929 672 569 624 430 610x915x66/78 250 1F HTMBL2448.2 1282 1179 1234 672 569 624 430 1220x610x66/78 250 1F TURE HTMBP-Shallow model with upper air inlet6 Reference Dimensions (mm) B B1 B2 H For Filters Neck UxP* Stock* EQUIP- A A1 A2 LxHxP (mm) inlet MENTS (mm) 1F HTMBP1212.2 367 264 319 367 264 319 280 305x305x66/78 1F7 HTMBP1224.2 672 569 624 367 264 319 280 305x610x66/78 150 1F HTMBP1818.2 519 416 471 519 416 471 280 457x457x66/78 150 1F MOTORS HTMBP2121.2 597 494 549 597 494 549 280 535x535x66/78 200 1F AND HTMBP2323.2 637 534 589 637 534 589 280 575x575x66/78 200 1F HTMBP2424.2 672 569 624 672 569 624 280 610x610x66/78 250 1FTURBINES HTMBP2436.2 977 874 929 672 569 624 280 610x915x66/78 250 1F HTMBL2448.2 1282 1179 1234 672 569 624 280 610x915x66/78 2508 250 ADSOR- UxP (*) Stock TION AND Units per box F: Manufacturer, S: Stock, SL: Limited Stock DESODO- RIZATION Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com9 138 Fax +34 937 862 493 INTER- NATONALNORMATI- VE
Equipments 0 Technical Documentation INFORMA- TION HTMBL-Air intake at the top 1 PRE- FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 139 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 Equipments Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comINFORMA- HTMBL-Air intake at the side Fax +34 937 862 493 TION 1401 PRE- FILTERS G2-G42PAINTINGS BOOTHS3PRODUCTS CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0 INFORMA- TION 1 PRE- FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TUREHTMBP-Shallow model with upper air inlet 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 141 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 Equipments Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comINFORMA- 142 Fax +34 937 862 493 TION1 PRE- FILTERS G2-G42PAINTINGS BOOTHS3PRODUCTS CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0Metal Housing INFORMA-90-110 TIONFitting elements 1Terminal Diffuser for replaceable HEPA/ULPA filters, for PRE-air diffusion in Clean Rooms with turbulent and laminar FILTERSflow. G2-G4 2Features techniques PAINTINGS BOOTHSType: Diffuser Terminal unit for ceiling or wall installation forthe final filtration of a Clean Room. 3Construction: Airtight welded electrogalvanised steel, whiteepoxy paint (RAL 9010) and kiln dried. PRODUCTSAir intake: At the top (HTMBS) or at the side (HTMBL), circu- CONFORlar, with an attachment neck. M5-F9Filter attachment: In the lower part, against the smoothframe, one single piece and held by attachment devices that 4exert a continuous and constant pressure.For filters: Filters of 90 and 110 mm. in depth. EPA/HEPA /ULPAAdvantages 5- Smooth coating, facilitates cleaning the diffuser grid.- Internal centring devices for filters and fixed moutings for the positionig of the filter inside the housing, HIGH TEMPERA- preventing the filter from falling.- Easy filter assemble and replacement. TUREINSTALLATION- Design of a rigid construction, allows an easy and fast assembly or installation. 6- Installation in roof side or superior entrance.- In addition it is equipped with four squares drilled for its suspension. EQUIP- MENTS 7 MOTORS AND TURBINESSteel plenum Moutings for filter Probes for integrity Diffuser grids: Perforated 8 retention testiong and differential or ratational, painted in pressure measurement white (RAL 9010) ADSOR- TION AND DESODO- RIZATION 9 Venfilter [email protected] 143 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE
0 EquipmentsINFORMA- References TION HTMBL-Air intake at the side1 Dimensions (mm) For Filters Neck PRE- LxHxP (mm) inlet FILTERS Reference A A1 A2 B B1 B2 H (mm) UxP* Stock* G2-G4 HTMBL1212.4 367 264 319 367 264 319 325 305x305x90/110 150 1F HTMBL1224.4 672 569 624 367 264 319 325 305x610x90/110 150 1F2 HTMBL1818.4 519 416 471 519 416 471 375 457x457x90/110 200 1F HTMBL2424.4 672 569 624 672 569 624 425 610x610x90/110 250 1FPAINTINGS HTMBL2436.4 977 971 929 672 569 624 425 610X915x90/110 250 1F BOOTHS HTMBL2448.4 1282 1179 1234 672 569 624 425 1220x610x90/110 250 1F3 HTMBL-Air intake at the topPRODUCTS Dimensions (mm) For Filters Neck CONFOR LxHxP (mm) inlet M5-F9 Reference A A1 A2 B B1 B2 H (mm) UxP* Stock*4 HTMBS1212.4 367 264 319 367 264 319 375 305x305x90/110 150 1F HTMBS1224.4 672 569 624 367 264 319 375 305x610x90/110 150 1FEPA/HEPA HTMBS1818.4 519 416 471 519 416 471 425 457x457x90/110 200 1F /ULPA HTMBS2424.4 672 569 624 672 569 624 465 610x610x90/110 250 1F HTMBS2436.4 977 874 929 672 569 624 465 610x915x90/110 250 1F5 HTMBS2448.4 1282 1179 1234 672 569 624 465 1220x610x90/110 250 1F HIGH UxP (*) StockTEMPERA- Unidades por caja F: Fabricar, S: Stock, SL: Stock Limitado TURE 144 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com6 Fax +34 937 862 493 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0 Technical Documentation INFORMA- TION HTMBL-Air intake at the top 1 PRE- FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 145 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 EquipmentsINFORMA- TION1 PRE- FILTERS G2-G42PAINTINGS BOOTHS3 HTMBL-Air intake at the side Venfilter [email protected] Tel +34 937 862 607 www.venfilter.comPRODUCTS 146 Fax +34 937 862 493 CONFOR M5-F94EPA/HEPA /ULPA5 HIGHTEMPERA- TURE6 EQUIP- MENTS7 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Equipments 0 INFORMA- TION 1 PRE- FILTERS G2-G4 2 PAINTINGS BOOTHS 3 PRODUCTS CONFOR M5-F9 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9Venfilter [email protected] 147 INTER-Tel +34 937 862 607 www.venfilter.com NATONALFax +34 937 862 493 NORMATI- VE
0 EquipmentsINFORMA- Plastic Housing TION Fitting Elements1 Terminal Diffuser for replaceable Laminarven type PRE- HEPA/ULPA filters for air diffusion in Clean Rooms with FILTERS turbulent and laminar flow. G2-G4 Features techniques2 Type: Diffuser Terminal unit for ceiling or wall installation for the final filtration of a Clean Room.PAINTINGS Construction: Manufactured in Self-Extinguishable Thermo- BOOTHS formed Polystyrene. The lower part is manufactured in extru- ded aluminium profile and painted in white epoxy (RAL 9010).3 Air intake: Lateral, circular, with an attachment neck Installation: Its lightweight design and rigid constructionPRODUCTS makes it easy and quick to fit. It also has four fastening squa- CONFOR res for its attachment. M5-F9 Filter attachment: In the lower part, against the smooth frame, in one single piece and held by attachment devices4 that can be slid and extracted by a guide, which exert a conti- nuous and constant pressure.EPA/HEPA For filters: Laminarven with a depth of 69 mm. /ULPA Optionally are manufactured with a system for regulating the flow from the room. (HTPBCR)5 Advantages HIGHTEMPERA- - Marked weight reduction with respect to pre-existing terminal boxes. - Smooth coating, facilitates easy cleaning of the diffuser grid. TURE Plastic plenum White-painted (RAL 9010) Sliding and extractable Probes for integrity testing6 148 extruded profile frame on moutings for filter positio- and differential pressure the lower part of the unit ning measurement EQUIP- MENTS Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com7 Fax +34 937 862 493 MOTORS ANDTURBINES8 ADSOR- TION AND DESODO- RIZATION9 INTER- NATONALNORMATI- VE
Search
Read the Text Version
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 76
- 77
- 78
- 79
- 80
- 81
- 82
- 83
- 84
- 85
- 86
- 87
- 88
- 89
- 90
- 91
- 92
- 93
- 94
- 95
- 96
- 97
- 98
- 99
- 100
- 101
- 102
- 103
- 104
- 105
- 106
- 107
- 108
- 109
- 110
- 111
- 112
- 113
- 114
- 115
- 116
- 117
- 118
- 119
- 120
- 121
- 122
- 123
- 124
- 125
- 126
- 127
- 128
- 129
- 130
- 131
- 132
- 133
- 134
- 135
- 136
- 137
- 138
- 139
- 140
- 141
- 142
- 143
- 144
- 145
- 146
- 147
- 148
- 149
- 150
- 151
- 152
- 153
- 154
- 155
- 156
- 157
- 158
- 159
- 160
- 161
- 162
- 163
- 164
- 165
- 166
- 167
- 168
- 169
- 170
- 171
- 172
- 173
- 174
- 175
- 176
- 177
- 178
- 179
- 180
- 181
- 182
- 183
- 184
- 185
- 186
- 187
- 188
- 189
- 190
- 191