Instruction Manual Purebeau Fibroblast Pen Art. No.: 10.trs DS2 10.elite 3.5 Document: GA_Fibroblast_Pen_rev01
Purebeau Fibroblast Instruction ManualContents Please note............................................................................. 2 Disclaimer ............................................................................. 2 Operating panel features ....................................................... 3 Information and part names .................................................. 4 Technical information ........................................................... 5 Operation............................................................................... 5 Safety instructions - Contraindications ................................. 6 Use ........................................................................................ 7 Cleaning and Maintenance.................................................... 8 Function testing Repairs Complaints .................................. 8 Hygiene instructions ............................................................. 9 Delivery contents .................................................................. 9 Guarantee policy ................................................................. 101 ga_fibroblast_pen_rev01_en
Purebeau Fibroblast Instruction ManualPlease noteThis instruction manual outlines the intended uses ofthe \"PUREBEAU Fibroblast\" device, and serves toreduce any risks associated with possiblemalfunction or damage to the device. Any personwishing to handle, use, clean, maintain or otherwisecontrol this device must carefully read and follow thisinstruction manual.DisclaimerThis device must only be operated by authorisedmedical professionals, cosmeticians, or other trainedpersonnel. Training by Purebeau New CosmeticsGmbH is mandatory for use.Please note the contraindications.No liability for the operation or misuse of this device,or any consequences thereof, in non-compliancewith the operation manual, will be assumed by themanufacturer.ga_fibroblast_pen_rev01_en 2
Purebeau Fibroblast Instruction ManualOperating panel features Figure 1: Powerbox3 ga_fibroblast_pen_rev01_en
Purebeau Fibroblast Instruction Manual Figure 2: Fibroblast PenInformation and part names 1. Power LED 2. Connector cable with DS-2 plug, or 3.5mm jack plug for connecting to a PMU device from Purebeau New Cosmetics GmbH. 3. Trigger button 4. Head attachment 5. Applicator needlega_fibroblast_pen_rev01_en 4
Purebeau Fibroblast Instruction ManualTechnical information 10trs DS2TypeVoltage supply 5-10VPower consumption 1,75 VAPen weight 100gPen dimensions L 150mm D 22mmCompatible devices PUREBEAU I / MAGIC LINER PUREBEAU LADYLINER PUREBEAU II TRS250 Circle ProOperationThe \"PUREBEAU Fibroblast\" device was manufacturedin accordance with VDE regulations and is delivered tothe customer in physically impeccable condition. It shouldonly be operated in conjunction with a PMU device fromPurebeau New Cosmetics GmbH. The PMU device is to beattached as quickly as possible to the output port of the5 ga_fibroblast_pen_rev01_en
Purebeau Fibroblast Instruction ManualFibroblast pen in order for it to be operated.Only the manufacturer or another authorised, technicallytrained person authorised by the manufacturer may open thedevice for maintenance and repairs.The device should only be operated indoors and should beused at an operating temperature of between 10°C and 35°Cin order to avoid impaired function.Safety instructions - ContraindicationsThe \"PUREBEAU Fibroblast\" device must not be used incase of any of the following, else there may bedetrimental health effects: fever heart complaints partial loss of sensation (a warning sign for pain) local inflammatory processes pregnancy neurological illnesses after consuming alcohol feeling unwell, or acute illness in any case of doubt, please consult your physician before commencing treatment in the case of implanted devices (e.g. pacemakers)Whenever the safe operation of the device can no longer beassured, the device must be made inoperative and measurestaken to ensure against accidental operation.It must be assumed that the device can no longer be usedsafely if: the device shows visible signs of damage the device no longer functionsga_fibroblast_pen_rev01_en 6
Purebeau Fibroblast Instruction Manual the device has been stored in poor conditions the device has been mishandled or exposed to stresses during transport. has been brought from a very cold, into a warm place. The condensation that forms on warming can potentially damage the device. Leave the device to warm up at room temperature before operating.Regularly check the physical integrity of the device, e.g.checking for damage to the outer casing. Repairs must only becarried out at specialised repair centres.UseThe PUREBEAU Fibroblast Pen is used for skin tightening. Toachieve this, a plasma is created by an electrical dischargewhich acts by subliming the tissue at the application site. Thisoccurs in a limited area due to the very short burst of heatinput. Almost no heat is transmitted to the bordering tissues.This selective subliming leads to an enhanced regeneration ofthe entire treatment area, with the treatment being non-aggressive due to its selectivity.The pen is made ready for use by inserting the applicator intothe head attachment. Please push the applicator as far aspossible into the head attachment until it stops, and thentighten the attachment cover by hand. Please do not useany tools when tightening or loosening the attachmentcover.To produce the electrical discharge, the pen must beconnected up to a Purebeau New Cosmetics PMU device. Thelist of compatible devices can be found under the technicalinformation heading. The PMU device should be set tomaximum on the relevant channel.Then, position the applicator around 1mmm above thetreatment area. Care must be taken when doing this to ensuregood stability and firm support in the treatment area.7 ga_fibroblast_pen_rev01_en
Purebeau Fibroblast Instruction ManualThen, press the trigger button (3). If the distance is correct, anarea of light appears and the treatment begins. Take care notto apply the treatment for too long in any given area.Replace the applicator after each use.Cleaning and MaintenanceBefore any cleaning or sterilising, the device must bedisconnected from the PMU device. Occasionally, the deviceshould be cleaned externally with a soft, lint-free cloth with aweak disinfectant, if needed (e.g. a 50% water - 50% 1-propanol solution).All anodised surfaces and components of the FIBROBLASTpen incl. accessories should be cleaned using a disinfectantas specified by the DGHM, such as LYSETOL MED. Careshould be taken when selecting a disinfectant to ensure that itis suitable for use on aluminium and that it meets hygieneregulations. -Follow the operator advice, and if necessary ask the supplier for more information-Function testing RepairsComplaintsErrors: The pen does not function / the LED (1) doesnot light up Please check the connection from the PowerboxSolution: to the PMU device. Please check whether the PMU device functions correctly at maximum speed with a PMU pen connected to the same output.Errors: The pen does not function / the LED (1) lightsup. Please check correct distance from theSolution:ga_fibroblast_pen_rev01_en 8
Purebeau Fibroblast Instruction Manual applicator has been observed, and whether the trigger button (3) has been operated correctly. Check that the head attachment is firmly fitted.If the handpiece still does not operate despite taking thesesteps, please inform Purebeau New Cosmetics GmbH.Hygiene instructionsThe applicators for the Fibroblast pen are single-use only. Assuch, it is vital that a new applicator is used for each customer.The applicators should be disposed of in a dedicated wastecontainer after use.Delivery contents Pen with Powerbox Instruction Manual 5 sample applicators9 ga_fibroblast_pen_rev01_en
Purebeau Fibroblast Instruction ManualGuarantee policyFor the device: Purebeau Fibroblast 10trs DS2Serial number From the date of purchase: Until:Stamp SignatureThe manufacturer offers a 24-month guarantee coveringthe entire device. Only guarantee claims based ondefects and malfunctions due to material faults andmanufacturing faults are covered. WarningThe guarantee is void if unqualified or unauthorisedpersonnel attempt to repair the device, or in cases ofimproper use.ga_fibroblast_pen_rev01_en 10
Purebeau Fibroblast Instruction ManualManufacturer: PUREBEAU NEW COSMETICS GmbH Mozartstraße 12 13158 Berlin Germany www.purebeau-pro.com11 ga_fibroblast_pen_rev01_en