Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore SolarEdge Commercial Catalogue

SolarEdge Commercial Catalogue

Published by ef_golan, 2015-07-14 12:55:24

Description: SolarEdge Commercial Catalogue_ROW_6.6.17_online

Search

Read the Text Version

IMPROVED BOTTOM LINE& PV ASSET MANAGEMENTSolarEdge Commercial Offering

1.63MW SolarEdge system, The Netherlands Installed by AliusEnergy2 SolarEdge Commercial Offering

Content04 SolarEdge Fact Sheet06 Moving Forward to DC Optimized Inverters08 PV Asset Management with Module-Level Monitoring14 Maximum Energy Yield in Commercial Installations16 Future Compatibility & Warranty18 A Higher Lifetime Value20 Commercial System Diagram22 200kWp System BoS Comparison24 200kWp Electrical Diagram Comparison26 1MWp System BoS Comparison28 1MWp System Comparison - Electrical Diagram30 1MWp Detailed SolarEdge Schematic32 Product Datasheets 34 SE15K-33.3K Three Phase Inverter Datasheet 36 SolarEdge Power Optimizer – P600-700 38 SolarEdge Control & Communication Gateway 40 Environmental Sensors42 Analog Sensor Connections44 SolarEdge Global Services www.solaredge.com 3

SolarEdge Fact SheetAbout UsIn 2006, SolarEdge invented an intelligent inverter solution that has changed the way poweris harvested and managed in PV systems. Since beginning shipments in 2010, SolarEdge hasshipped more than 1.4GW of its DC optimized inverter solution and its products have beeninstalled in PV systems in more than 70 countries. SolarEdge is traded on the NASDAQ underthe SEDG symbol.Vision Bankability> For every solar module to > Bankable in major European be individually managed and North American solar by DC-DC module-level financing institutions and banks electronics > Publicly traded on NASDAQ> To accelerate the as SEDG pace toward grid parity and make clean energy affordable and widespread Power Optimizers Shipped (Cumulative) Business 5 Figures Units Shipped (M) 4> Received nearly 30 > 5,600,000 power 3 awards, from prestigious optimizers and 2 organizations ranging over 245,000 inverters from Red Herring to Frost shipped worldwide & Sullivan > Monitoring system 1 continuously tracks over 100,000 PV installations 0 2012 2013 2014 Q1 20154 SolarEdge Commercial Offering

Global Outreach> Products sold in 38 countries> Sales via leading integrators and distributors> Follow the sun call centers> Local expert teams> Technical and sales training> Global manufacturing with tier 1 electronic manufacturersProduct Reliability 45 awarded patents and 130> Long product warranties: additional patent 25-year power optimizer warranty applications and 12-year inverter warranty, extendable to 20 or 25 years> Each SolarEdge product and component undergoes rigorous testing> Products and components have been evaluated in accelerated life chambers> Reliability strategy includes proprietary application specific ICs (ASIC) www.solaredge.com 5

1MW SolarEdge system, Hoffenheim, Germany Installed by Wircon6 SolarEdge Commercial Offering

Moving Forward to DCOptimized InvertersSignificance of Inverter SelectionInverter selection is key for the lifetime planning and performance of commercial PV systems.While inverters may only account for ~10% of the system cost, they:1. Influence ~30% of system cost (EBOS, inverter, labor)2. Manage 100% of system production3. Control O&M expenses by enabling PV Asset managementReduced BoS Costs Standard Inverter SolarEdge DC OptimizedUp to 15kW per string allows for more Invertermodules per string. This leads to fewerstrings per inverter and thereforeless wiring, combiner boxes, and fuses.This reduces BoS costs by up to 50%.Lifetime Revenue Standard inverter SolarEdge 200 kW DC 149.5 kW DC 34% addedMore Modules powerWith module-level power optimizationand maximum design flexibility, moremodules can be installed on the roof,enabling a shorter project payback period.More EnergyThe module-level MPPT eliminates losses to maximize power from each individual module, offering more energyproduction from the PV system. This technology future proofs the system against potential risks that could causedecreased lifetime energy production.System Lifetime O&M CostsFuture Compatibility & WarrantyLow-cost inverter replacement (~40% less than traditional inverters), long inverter warranty, free lifetimemonitoring, and the ability to install different power classes/brands in the same string, decrease future costs.Cost-Saving Maintenance & Higher System UptimeFree module-level performance monitoring & remote maintenance for system lifetime lead to more effective andefficient O&M by decreasing trips to sites, reducing the amount of time spent on site, and increasing system uptime.Enhanced SafetyThe DC disconnect is designed to automatically drop DC current, as well as voltage fromall DC cables, whenever inverter or grid power is shutdown. The voltage of each moduleis reduced to 1V. www.solaredge.com 7

1MW SolarEdge system, Florida, United States Developed and installed by Region Solar & Sol Integrators8 SolarEdge Commercial Offering

PV Asset Managementwith Module-Level MonitoringAs a strategic O&M tool for optimum plant operation and PV asset management, the SolarEdgecloud-based monitoring platform increases system uptime.As equipment prices drop and system sizes trend upward, PV projects are increasingly seen as secure long-terminvestment opportunities. Like any financial asset, PV systems must be monitored and managed to realize theirfull potential.Traditional inverters offer limited information, such as string-level or system-level monitoring that can indicateunderperformance of the array, but little else. It then becomes costly and time consuming to send skilledtechnicians to perform on site troubleshooting on invertersoperating under load and on DC lines at nearly 1000V.They must connect expensive equipment to thearrays in an effort to ‘sift through the tea leaves’of complex IV trace curves to detect issues. Cost Production MinimizationThe SolarEdge DC optimized inverter solution offers Transparency PV Asset Reducedadvanced PV monitoring and asset management Management Riskthrough its cloud-based monitoring platform.Power optimizers are permanent fixtures on the arraythat constantly track MPP and report high-resolutiondata on module performance.The SolarEdge monitoring platform transforms O&M Compliance Protectionfrom a manual, resource-intensive process to anautomated, at-a-glance service. The solution deliversmodule-level insights and ensures that a plant isperforming to the best of its ability at all times. www.solaredge.com 9

PV Asset Managementwith Module-Level Monitoring (cont.)SolarEdge's Monitoring Platform Features:1. Real-time remote monitoring at the module, string, and system levelsThe logical layout displays the electrical connectivity The hierarchy layout displays groupingbetween modules, strings and inverter of components per inverter2. Comprehensive analytics tracking and reports of energy yield, system uptime, performance ratio, and financial performanceDashboard - Energy production is displayed Performance Ratio - Analyze and track the system'son a weekly, monthly and yearly resolution performance ratio10 SolarEdge Commercial Offering

3. Pinpointed and automatic alerts for immediate fault detection, accurate maintenance, and rapid response. The alerts show the specific fault location, fault description, and fault status. Energy thresholds can be set alerts for underperforming modules. Custom settings available for time of day and offset from sunrise and sunset4. The time-of-use feature allows system owners to define peak and off-peak rates in order to track expected PV revenue. This may be used as an indication of the systems ROI. www.solaredge.com 11

PV Asset Managementwith Module-Level Monitoring (cont.)5. Accurate and remote troubleshooting for fast and efficient resolution with minimal and shortened onsite visits. Examples of identifying underperforming modules: Soiling Before cleaning After cleaning Potential Induced Degradation (PID) Looking at the modules within one string, it is possible No need to send technicians to the roof – to see the power degradation increasing towards the modules voltage is measured remotely negative pole.12 SolarEdge Commercial Offering

Bypass Diode Failure It is easy to identify the bypass diode failure with the module-level voltage graphs. The faulty module outputs at only 2/3 of the voltage.6. Consumption monitoring feature shows data on electricity consumption, PV production, and self-consumption. This feature is offered to system owners who install SolarEdge's Smart Energy Management feature set in their commercial system. www.solaredge.com 13

Maximum Energy Yieldin Commercial InstallationsUnavoidable in commercial installations, module-level mismatch occurs when modules in a stringhave different Maximum Power Points (MPPs). Arising from a variety of sources, the mismatchdecreases the energy yield of the entire string. Standard String Inverter SolarEdge DC Optimized Inverter Solution247W 250W 242W 248W 247W 250W 242W 248WImpp Impp Impp Impp Impp Impp Impp ImppVmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp> MPPT per entire string - all modules > MPPT per module - current & voltage operate at same current, regardless of their adjusted per module individual MPP > Maximum power produced and tracked> Weak modules reduce the performance of from each module individually all modules in the string or are bypassed > 2%-10% more energy from the> Power losses due to module mismatch PV systemThe SolarEdge DC optimized inverter solution mitigates power losses caused by mismatchbetween modules for maximum power generation from each module. With SolarEdge, strongmodules are not affected by the weaker ones.14 SolarEdge Commercial Offering

Examples of power mismatch in commercial installations:1. MANUFACTURING TOLERANCE MISMATCHFrom the manufacturing plant, the warranted Guaranteed poweroutput power range of modules may vary greatly. output from moduleA standard deviation of ±3% is sufficient to result manufacturersin ~2% energy loss. 0~+3%2. SOILING & SHADINGModule soiling, from dirt, bird droppings or snow, contributes to mismatch between modulesand strings. (Figure 1)While there may be no obstructions during site design, during a system’s lifetime, a tree may growor a structure may be erected that creates uneven shading. (Figure 2)Figure 1 - Soiling mismatch Figure 2 - Partial shading3. UNEVEN MODULE AGINGModule performance can degrade up to 20% over 20 years, however, each module agesat a different rate, which causes aging mismatch. Worst module Average Source: A. Skoczek et. al., “The results of performance measurements of field-aged c-Si Best module photovoltaic modules”, Prog. Photovolt: Res. Batch Appl. 2009; 17:227–240 www.solaredge.com 15

2.02MW SolarEdge system, Denmark16 SolarEdge Commercial Offering

Future Compatibility & WarrantyAs part of PV asset management planning, it is important to account for future costs that canimpact the return on investment of a PV system. The SolarEdge DC optimized inverter solutioneffectively minimizes these potential costs.Forward compatibility eliminates expensive stock of spare module inventory.> Replacement: SolarEdge allows modules of different power classes and brands in the same string.> Expansion: New power optimizers can be utilized in the same string with older models.SolarEdge offers 25-year power optimizer warranty, 12-year inverter warranty, and free monitoringfor 25 years. SolarEdge offers extended warranties at attractive prices.Power Optimizers Commercial Inverters Cloud-based 600W - 700W 15kVA - 33.3kVA Monitoring PlatformSolarEdge provides low-cost inverter replacement out of warranty> ~40% less than traditional inverters www.solaredge.com 17

1.3MW SolarEdge system, Arizona, USA18 SolarEdge Commercial Offering

A Higher Lifetime ValueThe SolarEdge DC optimized inverter solution offers a better LCOE for a system’s lifetime bymaximizing yield and reducing costs.The SolarEdge DC optimized inverter solution maximizes power generation at the individualmodule level, which leads to a higher lifetime revenue from PV systems. While the initial cost ofthe SolarEdge solution is generally slightly higher than the equivalent traditional inverter system,the total installation cost as well as the lifetime maintenance cost, is lower. This makes theSolarEdge solution more economically attractive. HIGHER LIFETIME VALUELIFETIME INVERTER BoS SYSTEM LIFETIME LIFETIMEREVENUE COST COST O&M COST VALUEStandard string inverter solution SolarEdge DC optimized inverter solution www.solaredge.com 19

Commercial System DiagramThe SolarEdge solution consists of inverters, power optimizers, and a cloud-based monitoringplatform. The technology provides superior power harvesting and module management byconnecting power optimizers at the module level. The ability to connect two modules to just oneoptimizer, combined with DC to AC conversion and grid interaction being centralized at a simplifiedPV inverter maintains a competitive cost structure. P600, P700 2-to-1 Power 15kVA - 33.3kVA Inverter Optimizer Configuration Lower cost compared to traditional inverters Module-level MPPT - no mismatch power losses Superior efficiency Strings of uneven lengths, modules on multiple Small, lightweight, easy to install azimuths & tilts Built-in communication hardware Compatible with SolarEdge inverters SE15K & larger Optional integrated DC Safety Unit SafeDC™ - automatic module-level safety shutdown Embedded feed-in limitation20 SolarEdge Commercial Offering

Cloud-based Monitoring Platform Full visibility of system performance Remote troubleshooting Access via browser or any Android, iOS smart phone or tablet Communication with the power optimizers over existing DC power lines (PLC)Control & CommunicationGatewayConnection of multiple sensors to analyze systemperformanceEnvironmental SensorsConnection of environmental sensors for advancedsite monitoring to calculate site performance ratioand environmental conditions www.solaredge.com 21

200kWp System BoS Comparison Comparison of a 200kWp SolarEdge system to a system with a traditional string inverter One system was designed with six SolarEdge 27.6kVA inverters and and 324 power optimizers in a 2:1 configuration and the other one was designed with six 27.6kVA standard string inverters. Electrical Diagram Comparison SolarEdge DC Optimized Inverter Solution Total of 18 strings SolarEdge Cabling Diagram Included DC cables Additional DC cables22 SolarEdge Commercial Offering

DC power (kW) SolarEdge DC Traditional String AC power (kW) Optimized Inverter Inverter Modules (310W, 72-cell) Inverters 200.88 200.88 No. of strings 165.6 165.6 Modules per string 648 648 DC Cable length (m) Cable Cost (%) 6 6 18 36Traditional String 36 18Inverter System 219 546Total of 36 strings 40% 100%Standard Inverter Cabling Diagram www.solaredge.com 23

200kWp Electrical Diagram Comparison SolarEdge DC Optimized Inverter Solution24 SolarEdge Commercial Offering

Traditional String Inverter System www.solaredge.com 25

1MWp System BoS Comparison Comparison of a 1MWp SolarEdge solution to an identical system with a traditional string inverter One system was designed with twenty-four SolarEdge 33.3kVA inverters and 1,680 power optimizers in a 2:1 configuration and the other one was designed with 24 standard string inverters. Electrical Diagram Comparison SolarEdge DC Optimized Inverter Solution Total of 72 strings SolarEdge Cabling Diagram Included DC cables Additional DC cables26 SolarEdge Commercial Offering

DC Power (kW) SolarEdge DC Traditional String AC Power (kW) Optimized Inverter Inverter Modules (310W, 72-cell) Inverters 1026.7 1026.7 No. of strings 799.2 800 Modules per string 3,312 3,312 DC Cable Length (m) 24 AC Cable Length (m) 24 144 Cost (%) 72 23 Total Copper Used (kg) 46 5364 Copper Ratio (%) 264 8,464 8,464 100Traditional String 79Inverter System 1696.4 1951.4 87 100Total of 144 stringsStandard Inverter Cabling Diagram www.solaredge.com 27

1MWp System Comparison - Electrical Diagram SolarEdge DC Optimized Inverter Solution28 SolarEdge Commercial Offering

Traditional String Inverter System www.solaredge.com 29

1MWp Detailed SolarEdge Schematic30 SolarEdge Commercial Offering

www.solaredge.com 31

1.22MW SolarEdge system, Denmark32 SolarEdge Commercial Offering

Product Datasheets www.solaredge.com 33

SE15K-33.3K Three PhaseInverter DatasheetSpecifically designed to workwith power optimizersSuperior efficiency (98%)Small, lightest in its class, and easy to installBuilt-in LAN internet connectionIP65 – Outdoor and indoor installationFixed voltage inverterOptional integrated DC Safety Unit- 2-pole Mechanical DC disconnect- DC surge protection (type II)- DC fuses SE15k SE16k SE17k SE25k SE27.6k SE33.3kOUTPUT 15000 16000 17000 25000 27600 33300 VARated AC Power Output 15000 16000 17000 25000 27600 33300* VAMaximum AC Power OutputAC Output Voltage - Line to Line 380 / 220 ; 400 / 230 480/277 VAC/ Line to Neutral (Nominal)AC Output Voltage - Line to Neutral Range 184 - 264.5 244-305 VACAC Frequency HzMaximum Continuous Output Current (per Phase) 50/60 ± 5Residual Current Detector 40 40 A/ Residual Current Step Detector 23 25.5 26 38Grids Supported - Three Phase 300 / 30 mAUtility Monitoring, Islanding Protection, Configurable 3 / N / PE ; 3 / N / PE VPower Factor, Country Configurable Thresholds 230 / 400 (WYE with Neutral) Yes34 SolarEdge Commercial Offering

SE15k SE16k SE17k SE25k SE27.6k SE33.3kINPUT 18750 20000 21250 33750 37250 44950 WRecommended Max. DC Power(1) 22 VDC(Module STC) 97.6 23 Yes 40 1000 VDCTransformer-less, Ungrounded 900 840 ADCMaximum Input Voltage (Voc) 98 750 98.5 40 %Nominal DC Input Voltage 97.7 23 37 98 %Maximum Input Current < 2.5 <4 98.3 WReverse-Polarity Protection YesGround-Fault Isolation Detection 1MΩ Sensitivity mmMaximum Inverter Efficiency mmEuropean Weighted Efficiency 97.7 98 mmNighttime Power Consumption kgADDITIONAL FEATURES RS485, RS232, Ethernet, RS485, Ethernet, ZigBee ˚C ZigBee (optional) (optional), Wi-Fi (optional)Supported Communication Interfaces IEC-62103 (EN50178), IEC-62103 (EN50178),STANDARD COMPLIANCE IEC-62109 IEC-62109, AS3100Safety VDE 0126-1-1, VDE-AR-N-4105, VDE-AR-N-4105, BDEW, AS-4777, RD-1663, DK 5940 BDEW, G59/3, CEI-016Grid Connection Standards AS-4777, EN 50438, VDE 0126-1-1,Emissions CEI-021, CEI-016(2)RoHS IEC61000-6-2, IEC61000-6-3 , IEC61000-6-2,INSTALLATION SPECIFICATIONS IEC61000-3-11, IEC61000-3-12, IEC61000-6-3, IEC61000-3-11,AC OutputDC Input FCC part15 class B IEC61000-3-12Dimensions (H x W x D)Weight YesOperating Temperature Range Cable Gland - diameter 15-21Cooling 2 MC4 pairs 3 MC4 pairsNoiseProtection Rating 540 x 315 x 260 Bracket Mounted (Bracket Provided) 33.2 45 -20 - +60 -20 - +60 (-40 version available) (M40 version -40 - +60) Fans (user replaceable)  <55 IP65 - Outdoor and Indoor(1) Limited to 135% of AC power.(2) For all standards refer to Certifications category in Downloads page* 33.3k requires separate 480V-MV transformer www.solaredge.com 35

SolarEdge Power Optimizer – P600-700The most cost-effective solution for module-leveloptimization in commercial installationsMore energySuperior efficiency (99.5%)Balance of System costs reduction; 50% less cables,fuses and combiner boxesFast installation with a single boltNext generation maintenance with module levelmonitoringModule-level voltage shutdownfor installer and firefighter safetyUse with two PV modules connected in seriesModule-level monitoring P600 P700 (for 2 x 60-cell PV modules) (for 2 x 72-cell PV modules)INPUTRated Input DC power (1) 600 700 W VDCAbsolute Maximum Input Voltage 96 125 VDC(Voc at lowest temperature) ADC %MPPT Operating Range 12.5 - 80 12.5 - 105 %Maximum Continuous Input Current (Isc) 10 ADC VDCMaximum Efficiency 99.5 VDCWeighted Efficiency 98.6Overvoltage Category IIOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER)Maximum Output Current 15Maximum Output Voltage 85OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)Safety Output Voltage per Power Optimizer 136 SolarEdge Commercial Offering

P600 P700 (for 2 x 60-cell PV modules) (for 2 x 72-cell PV modules)STANDARD COMPLIANCE FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3EMC IEC62109-1 (class II safety)Safety YesRoHSFire Safety VDE-AR-E 2100-712:2013-05INSTALLATION SPECIFICATIONSCompatible SolarEdge Inverters Three phase inverters Three phase inverters SE15K & larger SE16K & largerMaximum Allowed System Voltage 1000 Vdc mmDimensions (W x L x H) Pxxx-2 series 141 x 212 x 40.5 mm Pxxx-5 series gr 128 x 152 x 43 128 x 152 x 48 grWeight (including cables) Pxxx-2 series 1100 m Pxxx-5 series ˚C 930 %Input Connector MC4(2)Output Connector MC4Output Wire Length 1.2 (portrait orientation) or 1.2 (portrait orientation) or 1.8 (landscape orientation) 2.1 (landscape orientation)Operating Temperature Range(3) -40 - +85Protection Rating Pxxx-2 series IP65 Pxxx-5 series IP68Relative Humidity 0 - 100(1) Rated combined STC power of 2 modules connected in series. Module of up to +5% power tolerance allowed.(2) For other connector types please contact SolarEdge.(3) For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to “Power Optimizers Temperature De-Rating Application Note”for more details.PV SYSTEM DESIGN USING THREE PHASE THREE PHASE THREE PHASEA SOLAREDGE INVERTER(4)(5) SE15K & LARGER SE16K & LARGER SE33.3KCompatible Power Optimizer P600 P600 & P700Minimum String Power Optimizers 13Length PV Modules 26Maximum String Power Optimizers 30Length PV Modules 60Maximum Power per String 11250(6) 12750(7) WParallel Strings of Different Lengths or YesOrientations(4) P600 and P700 can be mixed in one string. It is not allowed to mix P600/P700 with P300/P350/P405/P500 in one string. 37(5) In a case of odd number of PV Modules in one string it is allowed to install one P600/P700 power optimizer connected to one PV Module.(6) For SE27.6K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 37,250W.(7) For SE33.3K: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 45,000W. www.solaredge.com

SolarEdge Control& Communication GatewayAll-in-one communicationgatewayEnvironmental sensors supportPower reduction interface & MV grid controlModbus meter readerEasy installation - DIN rail and wall mount SE1000-CCGPOWER Included, 100-240VAC, EU/UK/US/AU interchangeable, 2-pin plug VDCPower Supply - Wall Mount 9-14 WSupply VoltageConnector Type terminal blockPower Consumption <2ANALOG SENSOR INPUTNumber of Inputs Range 3 Resolution 0-30mV or 0-2V Accuracy 10 bitInput 1 0-2V or 0-10VInput 2 -20mA – 20mA +/- 1% f.sInput 338 SolarEdge Commercial Offering

COMMUNICATION INTERFACES SE1000-CCG °CEthernet InterfaceWireless Connections 10/100-BaseT mmPower Reduction Interface ZigBee module (*) kgRS232 Interface 4 control pins, 5V, GNDSUPPORTED RS485 DEVICES(a) For local connectionSolarEdge DevicesExport Inverter Data YesRevenue Meters YesExport Data to YesNon-SolarEdge Logger YesENVIRONMENTALOperating Temperatures -20 to 60Protection Rating IP20 IndoorMECHANICALMounting Type DIN Rail / Wall mountDimensions (L x W x H) 161.6 X 90 X 62Weight 0.5STANDARD COMPLIANCESafety UL60950-1, IEC-60950-1EMC FCC Part 15 class B, IEC61000-6-2, IEC61000-6-3(a) for supported protocols and devices, see link: www.solaredge.com/files/pdfs/se-gateway-supported-devices(*) sold separately - see individual product specs for supported locations www.solaredge.com 39

Environmental SensorsEnvironmental Monitoringof a SolarEdge SystemConnect environmental sensors to the SolarEdge inverterCalculate site performance ratioIrradiance, temperature, and wind measurements IRRADIANCE AMBIENT MODULE WIND TEMPERATURE TEMPERATURE VELOCITY SE1000-SEN-IRR-S1 SE1000-SEN-TAMB-S1 SE1000-SEN-TMOD-S1 SE1000-SEN-WIND-S1OUTPUT 0-1.4V 0-10V 4-20mA 4-20mAElectrical output range 0-1400 W/m2MEASUREMENT -50 to 50 ˚C -10 to 120 ˚C 0-50 m/sRange 1% of full scale 1% of full scale ±0.5 m/s or ±3%Accuracy ±5% of measuring value40 SolarEdge Commercial Offering

IRRADIANCE AMBIENT MODULE WIND SE1000-SEN-IRR-S1 TEMPERATURE TEMPERATURE VELOCITY SE1000-SEN-WIND-S1 SE1000-SEN-TAMB-S1 SE1000-SEN-TMOD-S1 Not neededINSTALLATION SPECIFICATIONS 165 x 105 x 10524V External Not needed Needed Needed 750Power Supply(SE1000-SEN-PSU-S1) Housing -Control & Communication Gateway (sold separately; SE1000-CCG) - Needed Aluminum (AlMgSi1)Dimensions 154 x 86 x 40 58 x 103 x 50 58 x 103 x 50 Cup star - mm grWeight 340 110 115 Synthetic, with fibre glass (PC-GF10) ˚CEnclosure type Powder-coated Polyamide Polyamide   aluminum Bottom - SyntheticOperating -20 to 70 -35 to 70 -35 to 70 (POM H2320)Temperature IP65 IP65 IP65Protection Rating 0 to 70 IP55The warranty and service for the sensors is provided directly by Ingenieurbüro Mencke & Tegtmeyer GmbH; for more details,please see www.imt-solar.com/products.html 24V EXTERNAL POWER SUPPLY FOR TEMPERATURE SENSORS (SE1000-SEN-PSU-S1)OUTPUTElectrical output 24V / 420mASTANDARD COMPLIANCESafety EN60950-1, UL508Immunity EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3,Emissions light industry level, criteria A EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3INSTALLATION SPECIFICATIONSMax. number of sensors 2powered by the power supplyDimensions 22.5 x 90 x 100 mm grWeight 170 ˚C  Operating Temperature -20 to 70Protection Rating IP20 IndoorThe warranty and service for the power supply is provided directly by Mean Well; for more details, please see www.meanwell.com/search/MDR-10/ www.solaredge.com 41

Analog Sensor Connections With the connection of sensors to the SolarEdge Control and Communication Gateway (CCG), PV system owners can monitor the site’s irradiance, temperature and wind velocity. This also enables the SolarEdge monitoring server to calculate and display the site performance ratio (PR), calculated based on the sensor readings.42 SolarEdge Commercial Offering

www.solaredge.com 43

984kW SolarEdge system, Germany44 SolarEdge Commercial Offering


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook