FACULTY OF ELECTRICAL ANDAUTOMATION TECHNOLOGYDIRECTORY OF MACHINERIESSENSOR TECHNOLOGY LABORATORY

MACHINE / Electro-mechanical Transducers kitINSTRUMEN o Variable Resistor o Variable Capacitor (Area)PRICE o Variable Capacitor (Distance)MODEL o Variable InductorYEAR OF o Variable Differential TransformerPURCHASE o Strain GaugeSERIAL NO.LOCATION TK2941E BRAND Feedback 2007 UNIT 4 UNITS TK2941E/ series TAGGING TATI/EI/SEN/HT 1-4 Sensor Technology Lab, FTKEA New Building1. INTRODUCTION This kit comprises six linear displacement transducers. It is the foundation kit for the TK2942 range and introduces some basic principles about transducers and associated instrumentation requirements.

2. SPECIFICATIONS • 10kΩ, 0.5W linear. • 2.5 – 20pF • 15-40Pf • 9Ω,23-81µH • Primary resistance: 6.3Ω, 140 turn. Secondary resistance: 2.5Ω, 140 turns • 2 off, 120Ω resistance3. FUNCTION Six linear displacement transducers are provided, each of which mounts onto the Test Rig. This is used to provide transducers displacement, the whole platform being moved to provide large displacements. The following linear transducers are provided;- • Linear Variable Resistor • Variable Area Capacitor • Variable Distance Capacitor • Variable Inductor – with sliding rod carrying a ferrite slug core. • Linear Variable Differential Transformer ( LVDT ) – This is uses a sliding core similar to the Variable Inductor and is used in conjunction with a phase-sensitive rectifier housed in the instrumentation module. • Strain Gauge - In addition to the linear displacement transducers, a Probe Assembly is provided for liquid depth measurement. This is intended to be used in salt water. Variations in depth or salt concentration vary the resistance between the probes. The resistive transducers are used either in a Wheatstone bridge or in the feedback loop of an operational amplifier. The capacitive and inductive transducers are used as frequency determining elements in an oscillator circuit. The inclusion of a discriminator and amplifier in the Instrumentation Module enables complex FM systems to be constructed.4. COURSES INVOLVE • Diploma in Industrial Automation Engineering (Mechatronics) • Diploma in Industrial Automation (Computer Integrated System) • Diploma in Industrial Automation Engineering (Electronics & Instrumentation) - Sensor Technology

5. SUPERVISOR / CO-ORDINATOR POSITION E-MAIL PHONE NO.BIL NAME Lecturer [email protected] 019 – 921 6058 1 Noraznafulsima binti Khamshah Instructor [email protected] 017 – 944 2711 2 Fatimah Rubaiah binti Che Jaafar6. REMARKS -7. SUPPLIER NAME / WEBSITE http://www.feedbackinc.com

MACHINE / Heat TransducersINSTRUMEN i. Thermal reed relay ii. Bi-metallic switchPRICE iii. ThermocoupleMODEL iv. ThermistorYEAR OF v. Platinum resistancePURCHASE vi. Heat BarSERIAL NO.LOCATION TK2941H BRAND Feedback 2007 UNIT 4 UNITS TK2941H/ series TAGGING TATI/EI/SEN/HT 1-4 Sensor Technology Lab, FTKEA New Building1. INTRODUCTION This tool provides a heat bar, three thermal transducers, a reed relay and a bimetal switch together with temperature measurement accessories.2. SPECIFICATIONS • Operating temperature 45oC. Hysteresis 3oC. Contact rating 10A. • Operating temperature 45oC. Differential 5oC. • Copper constantan junction approx. 50µV/oC. • Resistance at 20oC = 2kΩ • Resistance at 20oC = 100Ω

3. FUNCTION The test mount for the temperature transducers consists of a heat bar. This is equipped with a heater at one end and a multi-finned heat sink at the other. The temperature gradient produced along the bar is utilized to explore the characteristics of a number of transducers. These are attached to the bar in the desired position by a clip. Calibration is achieved by means of mercury in glass thermometer dipped into a water tank which may also be clipped to the bar. An auxiliary heater is provided which may be used in conjunction with the power amplifier to perform closed-loop temperature control experiments.4. COURSES INVOLVE • Diploma in Industrial Automation Engineering (Mechatronics) • Diploma in Industrial Automation (Computer Integrated System) • Diploma in Industrial Automation Engineering (Electronics & Instrumentation) - Sensor Technology5. SUPERVISOR / CO-ORDINATOR POSITION E-MAIL PHONE NO.BIL NAME Lecturer [email protected] 019 – 921 6058 1 Noraznafulsima binti Khamshah Instructor [email protected] 017 – 944 2711 2 Fatimah Rubaiah binti Che Jaafar6. REMARKS -7. SUPPLIER NAME / WEBSITE http://www.feedbackinc.com

MACHINE / Light TransducersINSTRUMEN i. Photo-transistor ii. Photo-diodePRICE iii. PhotoresistorMODEL iv. LampholderYEAR OF v. Optical FiltersPURCHASESERIAL NO. TK294 BRAND FeedbackLOCATION 2007 UNIT 4 UNITS TK2941L/ series TAGGING TATI/EI/SEN/LT 1-4 Sensor Technology Lab, FTKEA New Building1. INTRODUCTION An introductory assignment provides a comprehensive grounding in light theory and the operation of the light rig. A light source is provided by a lamp which attaches to the movable platform of the linear transducer test rig.2. SPECIFICATIONS • BP X 25 • RS component • RPY33 • MBC. 14.4v, 0.1A • 9 slide-mounted, 440, 470, 490, 520, 550, 580, 600, 690, 700nm. • 1 infra-red.

3. FUNCTION The mechanical arrangement permits each transducer to be rotated at right angles to the optical axis of the rig so that polar response curves can be obtained for each device. By adjusting the distance between the lamp and transducer, an output voltage / intersity characteristic may be plotted. A set of colour filters is provided. These clip over the window of the transducer box to enable the spectral responses of the various transducers to be measured.4. COURSES INVOLVE • Diploma in Industrial Automation Engineering (Mechatronics) • Diploma in Industrial Automation (Computer Integrated System) • Diploma in Industrial Automation Engineering (Electronics & Instrumentation) - Sensor Technology5. SUPERVISOR / CO-ORDINATOR POSITION E-MAIL PHONE NO.BIL NAME Lecturer [email protected] 019 – 921 6058 1 Noraznafulsima binti Khamshah Instructor [email protected] 017 – 944 2711 2 Fatimah Rubaiah binti Che Jaafar6. REMARKS -7. SUPPLIER NAME / WEBSITE http://www.feedbackinc.com

MACHINE / Measurements package : B. Power AmplifierINSTRUMEN A. Instrumentation Module C. Test RigPRICE o Wheatstone BridgeMODEL o Operational AmplifierYEAR OF o OscillatorPURCHASE o Frequency DiscriminatorSERIAL NO.LOCATION TK 294 , TK 2941A , TK 2941B BRAND Feedback 2007 UNIT 10 UNITS TK2941M TAGGING TATI/EI/SEN/IM 1-10 Sensor Technology Lab, Block A, Academic Building1. INTRODUCTION A. Instrumentation module: These contain four separate sections which may be configured to form sub-systems and systems using the patching leads provided. B. Power Amplifier: A unity gain power amplifier with an output capability of 4 watts. C. Test rig: Carries a moveable platform which supports a micrometer. This is used to provide the transducer displacement, the whole platform being moved to provide large displacements

2. SPECIFICATIONS • Wheatstone bridge with reference potentiometer and selectable value ratio arms. • Operational amplifier with selectable gain and differential input. • Centre frequency 465kHz.FM operation and on-board phase sensitive rectifier. • Unity voltage gain. Maximum output 4W. • Slide sale micrometer control with 25mm/full rotation micrometer. Sub-unit lock for Electro-Mechanical Transducer.3. FUNCTION Instrumentation module: • Wheatstone bridge – This is equipped with selectable ratio arms of 100Ω, 1kΩ, 10kΩ and 100kΩ, a reference potentiometer and a detector short circuit push-button switch. • Operational Amplifier – This module contains a differential amplifier with switches gains of 1, 10, 100 and 1000. The switched-gain amplifier is used as a general purpose amplifier; the differential input permitting its use with the Wheatstone bridge. • Oscillator – This is designed for use with the inductive and capacitive transducers as frequency determining elements. The centre frequency is 465kHz. • Discriminator – A FM discriminator used in conjunction with the oscillator module. Also included are the components for a phase-sensitive rectifier.4. COURSES INVOLVE • Diploma in Industrial Automation Engineering (Mechatronics) • Diploma in Industrial Automation (Computer Integrated System) • Diploma in Industrial Automation Engineering (Electronics & Instrumentation)5. SUPERVISOR / CO-ORDINATOR POSITION E-MAIL PHONE NO.BIL NAME Lecturer [email protected] 019 - 921 6058 1 Noraznafulsima binti Khamshah Instructor [email protected] 017 - 944 2711 2 Fatimah Rubaiah binti Che Jaafar6. REMARKS -7. SUPPLIER NAME / WEBSITE http://www.feedbackinc.com


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook