XRF Sample Preparation Catalogue 2018/19 Introducing the APEX™ Quick Release Die THE WORLD'S LEADING SPECTROSCOPIC ACCESSORY MANUFACTURER UK: 01689 892902 | www.specac.com | US: +1 866 726 1126



Contents Specac XRF Sample Preparation Specac caters to analysts using XRF in multiple industries including mining, cement, environment and geological sciences and many others. Our expertise has been gained over decades of experience in the field of analytical chemistry. Specac presses have been sold the world over, winning the seal of approval from customers everywhere. Contents page. 4 page. 5 AtlasTM Power Press page. 8 AtlasTM Autotouch Press page. 9 AtlasTM Manual Hydraulic Press page. 10 ApexTM Quick Release Die page. 12 Standard XRF Pellet Dies page. 15 XRF App Note page. 18 Fritsch XRF Milling page. 21 Sample Cups page. 23 Thin film Grinding & Fusion consumables Specac.com XRF Product Catalogue 2018/19 01

APEX™ Quick Release Die The First of its Kind, Automatic Pellet Extraction The first of its kind on the market, the new Apex™ Quick Release XRF die makes routine pellet preparation simpler and faster than ever before. The unique, patented sleeve design eliminates the effort-intensive pellet extraction step. THE WORLD'S LEADING SPECTROSCOPIC ACCESSORY MANUFACTURER UK: 01689 892902 | www.specac.com | US: +1 866 726 126

Power & Autotouch Atlas™ Series Presses Presses & Dies Page: 4 Specac's range of hydraulic presses are ideal for preparation of pellet samples for XRF analysis of cement, iron, and for other common samples. Benchtop sized presses have numerous effort saving features; they are ideal for manual and semi-automatic preparation of high-quality analytical samples. Manual Hydraulic Presses Page: 8 Pellet Dies & Accessories Page: 9 3rd Party Accessories Page: 13 onwards Specac.com XRF Product Catalogue 2018/19 03

Atlas™ Power Press Key Features: Compact benchtop Power Press Up to 25 Tonnes load Power-assisted hydraulic load application Single-phase AC power supply Simple, hassle free operation Multi-lingual LCD display PETG safety guards Low noise operation Fully CE Marked Load Options 8 Tonne 15 Tonne 25 Tonne Product Description: The Atlas™ Power Press is a benchtop power-assisted pellet pressing system that takes the stress out of routine XRF sample preparation in testing and quality control laboratories. The time and effort required to manually pump up to the required load is eliminated, and the repeatability and consistency of the pellet pressing process is improved by reducing operator error. Additionally, the Atlas™ Power Press features a large, easily accessible working area, intuitive button-press operation, and retractable safety guards that prevent application of a load unless closed in the safe position. Utilising ordinary single-phase power supplies, the Atlas™ Power Press can be installed in any laboratory and is ready for use without any additional set-up. Specac.com XRF Product Catalogue 2018/19 04

Atlas™ Autotouch Press Key Features: All Features of the Atlas Power Press plus: Programmable load cycle controlling ramp, dwell and release rates for maximum re-producibility Up to 40 tonnes load Maintain load feature ensures pressure is maintained indefinitely Auto-push feature to aid removal of the finished pellet Store up to 6 programs internally LED touchscreen operation Load Options 8 Tonne 15 Tonne 25 Tonne 40 Tonne Product Description: The Atlas™ Autotouch Press takes the advantages of the Atlas™ Power Press to the next level. Fully programmable load cycles of up to 10 steps per program ensure maximum consistency and repeatability of sample preparation for sensitive XRF measurements. This includes the ability to maintain a constant load over long periods with the maintain load feature. Retaining the same compact footprint and large working area of the Power Press frame, the Autotouch Press is enhanced with additional features such as the Auto-push (AP) feature that prompts the user to remove and invert the die for pellet extraction, and proceeds to apply the necessary load for pellet extraction upon re-closure of the safety guard when used with the Standard pellet dies family. For autonomous pellet production the ApexTM Quick Release Die must be used. Specac.com XRF Product Catalogue 2018/19 05

Atlas™ Power & Autotouch Press General Specifications: Ordering Information: Model Power & Autotouch Part Number Description Product Autotouch 40T Family 8T, 15T, 25T 8T: 1-8 Tonnes GS2583X Atlas AutoTouch 40T Hydraulic Press Autotouch Displayed Load GS2582X Atlas AutoTouch 25T Hydraulic Press GS2581X Atlas AutoTouch 15T Hydraulic Press 15T: 2-15 Tonnes 40T: 4-40 Tonnes GS2580X Atlas AutoTouch 8T Hydraulic Press Range 25T: 3-25 Tonnes GS2543X Atlas Power 15T Hydraulic Press PowerPress GS2542X Atlas Power 25T Hydraulic Press Footprint 425 x405mm 430 x405mm GS2540X Atlas Power 8T Hydraulic Press (W xD) Height Max. 640mm 660mm X is a power supply code. Use the following codes for each region. Working area 220 x155mm 240 x155mm 0-230V 50Hz (UK/EU) dimensions 1-110V 60Hz (USA) 2-100V 50/60Hz (JAPAN) (Dia. xH) 3-220V 50Hz (CHINA) 4-220V 60Hz (KOREA/KSA) Weight 95kg 130kg Working with the Atlas™ Autotouch The Atlas™ Autotouch press features an LED touchscreen that is used Press ready for operation to program a load cycle, to select previously entered programs from the program directory, to adjust the settings of the machine, and to provide status indications and warning messages to the user. The user can store up to six previously entered programs, or use a pre-programmed cycle referred to as the PZ program which has a basic routine built in already. The screen is clearly divided into three sections, one for the system Program in operation status (including current load, program selection, and information messages), one for the current program status, and a smaller section along the bottom containing the user controls (in green). The current program segment is highlighted when the press is running and indicated in the status area, while status messages appear in red text. Specac.com XRF Product Catalogue 2018/19 06

Atlas™ Power & Autotouch Press Programming Program Description segment Programming the press is easy. An empty program Pumps up to the target load. slot is selected, and individual segments are added, Pump edited, or deleted until the desired pressing cycle Hold Inserts a hold step with a has been built. Maintain predefined duration from 0.1 to 99.9 minutes, or until Safety Features Release commanded by the user. Stop The applied load is maintained by The Atlas™ Autotouch press has several safety the “Auto Top-up” feature that features. No load can be applied if the polycarbonate periodically tops up the pressure safety guard is open, and a message to close the in the system for a predefined guard will be displayed until it is closed. duration from 0.1 to 99.9 The progress of any program may be interrupted by minutes, or until commanded by pressing the stop key, which is a physical button on the user. the front panel of the press. Pressing the stop button Releases the applied load at one of will automatically advance the program to the load three pre-determined rates: fast, release step. medium, or slow. Ends the program. Auto-Push The Auto-Push (AP) feature, when selected, prompts the user to open the guard at the end of a program cycle in order to invert the die set and place the extractor cap ready for pellet removal. When the die set is returned to the press, closing the guard automatically initiates the application of a light load to push through the completed sample pellet. This feature makes the pressing easier when using the standard pellet die family. Programming screen \"Close guard\" safety message Specac.com XRF Product Catalogue 2018/19 07

Atlas™ Manual Hydraulic Press Part Number Key Features: GS25011 GS15011 Robust and reliable hydraulic press for low- volume sample preparation GS15100 GS15101 Manual load application using hand pump GS15051 Quick pressure release GS15052 GS15055 Analog pressure gauge Loads up to 25 Tons Polycarbonate safety shields Load Options 15 Tonne 25 Tonne Ordering Information Description Atlas Manual 25T Hydraulic Press Atlas Manual 15T Hydraulic Press Spares and Consumables Replacement seals and gaskets kit Hydraulic oil (1 litre) Low Tonnage Gauge Kits 0-1 tonne Gauge Conversion Kit 0-2 tonne Gauge Conversion Kit 0-5 tonne Gauge Conversion Kit Product Description: General Specifications: The Atlas™ Manual Hydraulic press is ideal Displayed Load Range 15T: 0-15 Tonnes for simple and low-cost laboratory sample 25T: 0-25 Tonnes preparation for XRF and can be used with Footprint 310mm x190mm our standard pellet dies. (W xD) Height Max. 610mm Load is applied by manually pumping the pressure system with a hand lever. The (at handle) press's simple and robust frame ensures reliable operation over many years, and is Working area dimensions 134mm x141mm readily convertible to other uses. (W xH) Weight 50kg Specac.com XRF Product Catalogue 2018/19 08

Apex™ Quick Release Die Key Features: Innovative Quick Release Die reduces operator involvement and frees the user to perform vital tasks Tedious removal, inversion and replacement of the die set for pellet extraction is completely eliminated No die assembly required Diameter Options 32 mm 40 mm Load Sample Clean & Reset Press Sample Sample Released Sleeve Engages Product Description: ApexTM Quick Release Die pellet pressing cycle diagram (right) Program the complete routine using the AtlasTM Autotouch Press Press Again The first of its kind on the market, the Apex™ Quick Release XRF die makes routine pellet preparation simpler and faster than ever before. The unique, patented sleeve design eliminates the effort-intensive pellet extraction step. Unlike traditional dies, which require the die set to be removed from the press, partly disassembled, and then returned to the press, the Apex™ Quick Release die presses and ejects the pellet automatically. The entire cycle can take as little as 2-3 minutes from loading the sample to retrieving the finished pellet when used in combination with the AtlasTM Autotouch Press Once the pellet is removed, the release mechanism is reset with the press of a button, and the die is immediately ready for the next sample. Specac.com XRF Product Catalogue 2018/19 09

Standard XRF Pellet Dies Key Features: Polished, precision-engineered pellet dies Compatible with all Specac presses and many others too (Optional) Tungsten carbide internal pellets (Optional) evacuation port Diameter Options 32 mm 40 mm Product Description: Standard XRF pellet dies for routine preparation of pellet samples. Simple and robust, they are perfect for the pressing of any sample. Polished internal pellets provide the highest quality analytical pellets. Tungsten carbide pellets are available to avoid Fe contamination and/or work with very abrasive samples. Specac.com XRF Product Catalogue 2018/19 10

General specifications for Atlas™ Series Dies Specifications Maximum Load Die Dimensions Weight 40 tonnes Ø65mm xH110mm 2.5kg Die 2.4kg 40mm Standard 2.5kg 2.5kg 32mm Standard 40 tonnes Ø65mm xH110mm 40mm Standard 40 tonnes Ø65mm xH110mm (with evacuation port) 32mm Standard 40 tonnes Ø65mm xH110mm (with evacuation port) Ordering information for the Atlas Standard Dies: Complete Die sets: Part Number Description With evacuation port: GS26101 32mm Atlas Standard Die GS26102 40mm Atlas Standard Die No evacuation port: GS26103 32mm Atlas Standard Die GS26104 40mm Atlas Standard Die Spares & Accessories: Part Number Description Die Body (with evacuation port): GS26111 GS26112 32mm Atlas Standard Die set 40mm Atlas Standard Die set GS26113 Die Body (no evacuation port): GS26114 32mm Atlas Standard Die set GS26121 40mm Atlas Standard Die set GS26122 Plunger for 32mm Standard die Plunger for 40mm Standard die GS26131 Internal pressing pellets (pair): GS26132 GS26133 32mm Stainless Steel GS26134 40mm Stainless Steel GS26141 32mm Tungsten Carbide GS26151 40mm Tungsten Carbide GS26152 Die base for 32mm and 40mm Standard dies O-ring kit for 32mm Standard die O-ring kit for 40mm Standard die GS26161 Extractor cap for 32mm and 40mm Standard dies Specac.com XRF Product Catalogue 2018/19 11

Analyzing cement using XRF Spectroscopy The annual demand for cement is almost 5bn Results: tons and is growing steadily. Specimens of Portland cement and a pre-mixed ‘Ready-to- A key building material and one of the ingredients of use’ cement were ground using the P6 ball mill at 300 rpm concrete, cement comprises limestone and clay, usually for 10 mins to ensure a fine powder (<60 microns). mined from nearby quarries close to manufacture plants. 6g of the fine powders from each sample were mixed with On site tests, including XRF analysis, are performed at the 1.5g of paraffin binder. quarry to ensure chemical composition of the rock meets requirements. The resulting mixtures were pressed into pellets using the Atlas® 25 Ton Manual Press and a 32mm die. The raw rock is then crushed and heated above 1000 °C in a kiln to become clinker. The clinker is also subjected to analysis by XRF. In the next stage, the clinker is ground into a fine powder This Table shows the complete list of elements detected and mixed with sulphate rich gypsum in varying amounts, to using XRF. produce different grades of cement, such as Portland cement for industrial construction or Ready-to-use cement for lighter jobs. A final XRF test is carried out. This note shows how XRF analysis can help to ensure your cement product quality is within specification and complies with standards like ASTM C114 or ISO/DIS 29581-2. The Specac Atlas® Presses and Dies are perfect for quick and easy XRF sample preparation. View the rest of our Applications notes on our website - www.specac.com Specac.com XRF Product Catalogue 2018/19 12

3rd Party Accessories Pelletizing Accessories Sampling Cups Thin Films Grinding & Fusion consumables Specac.com XRF Product Catalogue 2018/19 13

Sample milling for XRF Analysis X-ray fluorescence analysis is a standard technique for the quantitative determination of elements in solids. It is essential to control the particle size of the sample and the quality of the pellet which is used, for a proper and reproducible result. A typical mill to reduce the size of the solid and to produce a homogenous powder, which can be used in the pellet press, is a Planetary ball mill. The pulverisette-6 classic line is able to work with one 250ml bowl for 100ml of sample or with two 80ml bowls with 30ml of sample. As grinding media we recommend either zirconia or for harder materials tungsten carbide. The max feed size is 10mm. Recommended number of balls per grinding bowl: Grinding bowl 80ml 250ml Sample volume 10-30ml 30-125ml Ball diameter 20mm 5 15 30mm 6 The specification for the particle size is typically < 45µm. 80ml cement clinker is milled in a 250ml bowl. After 10 minutes we get this particle Size distribution: 125889 dQ3(x) 125889 Q3(x) Result Q3(x): 99.4% < 45µm Longer milling (dry) might not be possible. The sample starts to stick at the wall of the bowl and at the balls. Specac.com XRF Product Catalogue 2018/19 14

Pelletizing accessories & Consumables P6 Mill Planetary: High-speed planetary ball mill (up to 650rpm) Produces fine powders 40-200µm in size Grinding balls and bowls in a range of materials and capacities Maximum useful sample capacity of 450ml User friendly Safe-Lock System to prevent accidents Benchtop design makes it portable for in-field and lab work Easily grind hard, medium-hard, brittle and moist materials Sample support cups: Compressible cups that provide support to poorly binding samples that cannot form free-standing pellets Available in aluminium or plastic Lubricious plastic aids in pellet release Protective pellet films: Protect pressing surfaces from cross-sample contamination Applied to the surface in direct contact with the sample 32, 35 and 40mm diameters Product Description: The P6 Planetary Ball Mill is a high-performance benchtop grinding mill for XRF applications. Fitted with up to two grinding bowls, sample quantities up to 450ml may be quickly and efficiently reduced to tens of microns in size. Its user-friendly design makes the P6 is easy to operate both in the field and in the lab. Specac.com XRF Product Catalogue 2018/19 15

Ordering Information for Accessories & Consumables P6 Planetary Mill First select the material you want to work with, second select the number of balls per bowl you will need Selection of grinding bowls and grinding balls Material (bowl+balls) Main components of the material Density (g/cm3) Abrasion resistance Sample type Agate (99.9% SiO2) 2.65 Good Soft to medium-hard samples Zirconium oxide (96.2% ZrO2) Tungsten carbide (93% WC+6%Co) 5.7 Very good Fibrous, abrasive samples Silicon nitride (90% Si3N4) 14.9 Very good Hard, abrasive samples Hardened steel Abrasive samples, metal-free grind- 3.25 Extremely good ing Bowl: (11-12%Cr) Balls: (1.0-1.65%Cr) 7.9 Good Hard, brittle samples Number of balls per grinding bowl Ball diameter (mm) Grinding bowl volume (ml) 80 250 500 5 Number of balls 250 -300 1200 -1300 2000 -2500 10 Number of balls 15 Number of balls 25 -30 50 -150 100 -250 20 Number of balls 10 45 -50 70 -100 30 Number of balls 5 15 -20 25 -35 40 Number of balls - 05-06 - 10 - 4 Sample support cups Description PelletCups®Compressible Tapered Aluminium Briquetting Cup, 31.0mm Dia. x8.0mm Tall 1000/pk Part Number CX0505E PelletCups®Compressible Tapered Aluminium Briquetting Cup, 12.5mm Dia. x8.7mm Tall 250/pk CX0513E PelletCups®Compressible Tapered Aluminium Briquetting Cup, 34.6mm Dia. x9.3mm Tall 600/pk CX0535E PelletCups®Compressible Tapered Aluminium Briquetting Cup, 39.8mm Dia.x9.6mm Tall 600/pk CX0545E PelletCups®Compressible Tapered Aluminium Briquetting Cup, 44.9mm Dia. x9.6mm Tall 600/pk CX0547E CX0552E PlastiCup®Compressible Tapered Plastic Briquetting Cup, 31.0mm Dia. x6.4mm Tall 500/pk CX0553E PlastiCup®Compressible Tapered Plastic Briquetting Cup, 34.3mm Dia. x6.4mm Tall 500/pk CX0554E PlastiCup®Compressible Tapered Plastic Briquetting Cup, 39.7mm Dia. x6.4mm Tall 500/pk Protective pellet films Description SpectroPellet®Protective Die Pellet Film for 32mm dies; 500 per pkg Part Number SpectroPellet®Protective Die Pellet Film for 35mm dies; 500 per pkg CX7032E SpectroPellet®Protective Die Pellet Film for 40mm dies; 500 per pkg CX7035E CX7040E Specac.com XRF Product Catalogue 2018/19 16

Liquid & Solid Consumables for Liquid Sampling cups & Solid Sampling Page: 18 Specac offer a range of consumables for sampling of liquids and loose powders, including sample cups and thin-film sample support windows. Thin-film support windows A range of grinding and pelletizing additives may be purchased to aid Page: 21 pressing of certain samples. Borate fluxes for use with fusion ovens in preparation of fused sample beads are also available. Grinding, pelletizing & fusion consumables Page: 23 Specac.com XRF Product Catalogue 2018/19 17

XRF Sample Cup Guide Sample cups are disposable plastic containers used for sampling of liquids and powders, sealed with a thin film window that is transparent to the measuring X-Rays. There is a large variety of sample cups and film windows on offer, and the following serves as a rough guide to choosing the correct type. Choosing the right size Different spectrometers require different cup sizes. Consult the documentation for your spectrometer to determine the correct diameter and height of sample cup to fit the holder on the spectrometer. Single or double open-ended? A double open-ended cup is prepared by placing a film window over one end and then filling the cup from the opposite end so that the sample is supported directly by the film window. If the film window is very thin, or is prone to chemical attack by the sample, then it may not be desirable for the window to support the sample in this way for long periods. In these instances a single open-ended cup may be used that allows the sample to be supported by the cup itself during filling and storage, and only be supported by the window once inverted for measurement. Supporting thin film materials The supporting window must be transparent to all the signals produced by the analytes of interest, as well as chemically compatible with the sample. There is currently a large range of window materials available in various thicknesses to contain the sample, such as polypropylene, Kapton and Mylar®. Thicker films will be more durable, but will also attenuate the X-Ray signals more strongly. Chemical Mylar® Poly- ETNOM® Polypro- Kapton® Prolene® Ultra Zythene™ Acid, dilut. Acids, conc. ? ? Alcohols ? Aldehydes Alkalies, conc. Esters Ethers Aliphatic Hydro- Aromatic Hydro- Halogenated Ketones Oxidizing Agents N.B. — ASTM methods for analyzing sulfur in diesel stipulate the use of Kapton or Etnom windows only. Specac.com XRF Product Catalogue 2018/19 18

Sample Cups Single and double open-ended sampling cups in a variety of sizes to suit the majority of commercially available XRF Spectrometer systems. 1000 TrimLess® Sleeved Single and Double Open-Ended 1300 TrimLess® Sleeved Re-sealable double open-ended Completely envelops thin-film Re-sealable cap with integrated vent Eliminates thin-film trimming External Overflow reservoir integrated cap ThermoPlastic® seal venting \"Snap-On-Ring\" with bead-to-indent geometry 1400 Micro-sample Single Open-Ended 1500 Microporous Double Open-Ended Internal standard mounting option Top sample filling Dual ThermoPlastic® seal venting Film attachment provision \"Snap-On-Ring\" thin-flim attachment \"Snap-On-Ring\" thin-film attachment 1700 \"Snap-Post\" venting Single Open-Ended 1800 ThermoPlastic® seal venting Single Open-Ended External overflow reservoir External overflow reservoir \"Snap-On-Ring\" thin-film attachment \"Snap-On-Ring\" thin-film attachment 1900 \"Snap-On-Ring\" Double Open-Ended 2100 SpectroCup® Double Open-Ended Top sample loading TrimLess® sleeve envelops thin-film Top sample loading \"Snap-On-Ring\" thin-film attachment Internal overflow reservoir Specac.com XRF Product Catalogue 2018/19 19

Sample Cups Ordering information: TrimLess®Sleeved Sample Cups Spectrometer Codes: Part Number Series Dia. H. Vol. Spectrometer Code CX1060E S1, S2, X1, X2 CX1065E 1000 31.2mm 23.6mm 22 S1, S2, X1, X2 Spectro CX1070E S1, S2, X1, X2 Xepos CX1075E 1000 31.2mm 23.6mm 8 S1, S2, X1, X2 X-Lab 2000 S1 CX1083E H1 S2 CX1095E 1000 38.6mm 22.9mm 9 P1, R1, R2, R3 Xenemetrix CX1330E S1, S2, X1, X2 X-Calibur X1 1000 38.4mm 22.9mm 11 S1, S2, X1, X2 X2 CX1330-SE S1, S2, X1, X2 X-Cite CX1340E 1000 42.9mm 18.5mm 9 Rigaku R1 Spectrometer Code R2 Part Number 1000 43.4mm 39.9mm 7 S1, S2, X1, X2 Primus R3 CX1430E S1, S2, X1, X2 ZSX-100 1300 30.7mm 22.9mm 7 S1, S2, X1, X2 O1 CX1430-SE S1, S2, X1, X2 Rix CX1440E 1300 30.7mm 22.9mm 22 S1, S2, X1, X2 Oxford B1 CX1730E S1, S2, X1, X2 B2 1300 39.1mm 23.1mm 7 S1, S2, X1, X2 Lab-X B3 CX1730-SE S1, S2, X1, X2 Bruker B4 CX1740E Single Open-Ended Sample Cups S1, S2, X1, X2 CX1830E Manual S2 P1 Series Dia. H. Vol. Spectrometer Code Manual S4 P2 CX1830-SE S1, S2, X1, X2 P3 CX1840E 1400 31.0mm 22.4mm 8 S1, S2 Auto S2 P4 S1, S2, X1, X2 Auto S8 Part Number 1400 31.0mm 22.4mm 1 S1, S2, X1, X2 T1 CX1530E Panaltyical 1400 39.4mm 22.4mm 8 S1, S2, X1, X2, O1 Venus 200 H1 CX1530-SE O1 CX1930E 1700 30.7mm 23.1mm 15 Axios Epsilon 3 CX1930-SE 1700 30.7mm 23.1mm 19 MiniPal CX1935-OXE 1700 39.1mm 23.6mm 7 Thermo CX1940LE Advant'x 1800 31.0mm 22.1mm 7 Part Number Horiba CX2131E 1800 31.0mm 22.1mm 22 Sulfur Analyzers CX2132E CX2135E 1800 39.1mm 23.6mm 7 CX2140E CX2143E Double Open-Ended Sample Cups CX2144E CX2145E Series Dia. H. Vol. CX2146E CX2147E 1500 31.0mm 23.1mm 22 CX2148E CX2149E 1500 31.0mm 23.1mm 25 If your spectrometer is not listed CX2195E 1900 31.4mm 21.3mm 0.5 here, please contact Specac for 1900 31.4mm 21.3mm 13 advice on how to find the right 1900 31.2mm 38.4mm 13 sample cup. 1900 39.4mm 35.3mm 15 Double Open-Ended SpectroCup®Sample Cups Series Dia. H. Vol. Spectrometer Code 2100 30.9mm 29.2mm 12 S1, S2, X1, X2 2100 31.5mm 29.2mm 9 S1, S2, X1, X2 2100 34.3mm 29.7mm 9 P1, P2 2100 40.1mm 29.7mm 9 B1, B2, P1, R1, R2, R3 2100 40.1mm 29.7mm 19 B3, B4 2100 40.1mm 33.8mm 19 B3, B4 2100 44.7mm 29.5mm 25 P2, P3 2100 44.7mm 33.5mm 22 T1 2100 44.7mm 29.5mm 11 T2 2100 44.7mm 33.5mm 12 T3 2100 44.7mm 39.2mm 22 P4 2100 43.4mm 40.7mm 12 P1, R1, R2, R3 Specac.com XRF Product Catalogue 2018/19 20

Thin Film Windows Fabricated and stored under environmentally controlled conditions to avoid introducing trace levels of contaminants, they are available in a variety of formats including rolls (continuous and perforated), pre-cut sheets, or supported in a card frame for ease of application. Thin-Film Sample Support Windows Pre-cut circles available in Kapton®, Microporous, Mylar®, Polypropylene and Prolene® Roll available in Etnom, Microporous, Mylar®, Polypropylene, Prolene® and Ultra-Polyester® Perforated roll at 3\" lengths for a total of 1200 sheets available in Mylar®, Polypropylene and Prolene® All films available in different thicknesses from,1.5µm to 12µm SpectroMembrane® Thin film sample support in a frame for easy handling and to avoid contamination Automatically detaches from the carrier frame leaving a taut wrinkle- free sample support window Packaged in 100 units to match 100 sample cup sets Available in Etnom®, Kaptom®, Mylar®, Polypopylene, Prolene®, Ultra- Polyester® and Zythene® Available in pre-set thicknesses from 2µm to 12µm SpectroFilm® Safety Secondary Window Self-adhesive protective films Protects sensitive electronics from leakage such as, X-ray tube windows, X-ray detectors, windows and electronics Eliminates contamination issues Prevents costly clean-ups Available in Etnom®, Mylar® and Prolene® Available in 2 standard sizes 1.38\" (35mm) OD/ 0.78 (20mm) ID and 2.36\" (60mm) OD/ 1.65\" (42mm) ID Specac.com XRF Product Catalogue 2018/19 21

Ordering Information for Thin Film Windows Select from the available materials and sizes Material Thickness Precut Circles 500 or 1000 Roll 91.4m Roll -PrePerf 91.4m SpectroMembrane®100 pck SpectroFilm® 25 pck Kapton® pck Micropourous 7.5 μm - 63.5mm and 76.2mm - Mylar® 25µm 63.5mm - - - - 2.5µm 63.5mm 76.2mm 76.2mm - Polypropylene 3.5mm 76.2mm 63.5mm and 76.2mm 35mm OD/ 20mmID60mmOD/ Prolene® 3.6µm 42mm ID Etnom® 63.5mm and 89mm 76.2mm 76.2mm 35mm, 63.5mm and 76.2mm - 6.0µm - Ultra-Polyester® 6.0µm 63.5mm 76.2mm 76.2mm 63.5mm and 76.2mm - Zythene® 12.0µm 63.5mm 76.2mm 76.2mm 45mm, 63.5mm and 76.2mm 35mm OD/ 20mmID60mmOD/ 63.5mm 76.2mm 45mm, 63.5mm and 76.2mm 42mm ID 3.0µm - - 35mm, 63.5mm and 76.2mm - 4.0µm - -- - 1.5µm 35mm, 63.5mm and 76.2mm - 2.0µm 63.5mm 76.2mm 76.2mm - 35mm OD/ 20mmID60mmOD/ 2.5µm - - - 42mm ID - - - 35mm, 63.5mm and 76.2mm - 3.0µm - - 63.5mm and 76.2mm - 76.2mm 1.5µm 63.5mm and 76.2mm 6.0µm - -- 76.2mm - -- 63.5mm and 76.2mm - -- Specac.com XRF Product Catalogue 2018/19 22

Grinding & Fusion consumables Grinding and pelletizing additives X-Ray Mix® pre-weighted tablets (1/4g) (composition C: 48.7%; O: 42.6%; H: 8.1%; B: 0.6%) SpectroBlend® pre-weighted tablets (1/2g) (composition C: 81.0%; O: 2.9%; H: 13.5%; N: 2.6%) Boric Acid pre-weighted tablets (1/2g) (composition O: 77.6%; H: 4.9%; B: 17.5%) Liquid Binder® for difficult-to-bond samples Polymer ingredient (C6H9ON) in methylene chloride solvent X-Ray Mix® and SpectroBlend® also available in powder form FusionFlux® borate fluxing agent Lithium Tetraborate (Li2B4O7) based fluxes Blended with lithium bromide (LiBr) or lithium iodide (LiI) in blends from 0.5% to 1.5% Additional blends with 33% to 100% Lithium Metaborate (LiBO2) Formulations with non-wetting agents See ordering information for blends Other Accessories Sample powder compactors to flatten and level surface before pelletization Sample storage pods with 5 or 10 pods: catalog, store and gems, optical glasses and many other delicate items Specac.com XRF Product Catalogue 2018/19 23

Ordering Information Part Number Description CX600E X-Ray Mix®, Powder; 1lb per bottle CX625E X-Ray Mix®, 1/4gm Tablets; 500 tablets per bottle CX650E X-Ray Mix®, 1/2gm Tablets; 500 tablets per bottle CX660E SpectroBlend®, 44µm Powder; 1lb per bottle CX690E SpectroBlend®, 1/2gm Tablets; 500 tablets per bottle CX750E Boric Acid,1/2gm Tablets; 1000 tablets per bottle CX800E Liquid Binder®Additive; 1 Pint Pre-Fused FusionFlux®Formulation Lithium Tetraborate 100% (Li2B4O7); 1lb CX30-1000E Pre-Fused FusionFlux®Formulation with Non-wetting agent Lithium Tetraborate 99.5% (Li2B4O7) /Lithium Bromide 0.5%, LiBr; 1lb CX30-1100E CX30-1200E Pre-Fused FusionFlux®Formulation with Non-wetting agent Lithium Tetraborate 99.5% (Li2B4O7) /Lithium Iodide 0.5%, LiI; 1lb CX30-2000E Pre-Fused FusionFlux®Formulation Lithium Metaborate 100% (LiBO2); 1lb CX30-2100E Pre-Fused FusionFlux®Formulation with Non-wetting agent, Lithium Metaborate 99.5% (LiBO2)/ Lithium Bromide 0.5% (LiB); 1lb CX30-2150E Pre-Fused FusionFlux®Formulation with Non-wetting agent, Lithium Metaborate 98.5% (LiBO2)/ Lithium Bromide 1.5% (LiB); 1lb CX30-3000E Pre-Fused FusionFlux®Formulation Lithium Tetraborate 80% (Li2B4O7)/ Lithium Metaborate 20% (LiB02), 1 LB CX30-4000E Pre-Fused FusionFlux®Formulation Lithium Tetraborate 67% (Li2B4O7)/ Lithium Metaborate 33% (LiB02), 1 LB Pre-Fused FusionFlux®Formulation with Non-wetting agent Lithium Tetraborate 66.67% (Li2B4O7)/ Lithium Metaborate 32.83% CX30-4100E (LiB02)/ Lithium Bromide 0.5% (LiB), 1 LB Pre-Fused FusionFlux®Formulation with Non-wetting agent Lithium Tetraborate 66.67% (Li2B4O7)/ Lithium Metaborate 32.83% CX30-4200E (LiB02)/ Lithium Iodide 0.5% (LiI), 1 LB Pre-Fused FusionFlux®Formulation Lithium Tetraborate 50% (Li2B4O7)/ Lithium Metaborate 50% (LiBO2), 1 Lb CX30-5000E Pre-Fused FusionFlux®Formulation with Non-wetting agent, Lithium Tetraborate 49.75% (Li2B4O7)/ Lithium Metaborate 49.75% (LiBO2)/ Lithium Bromide 0.5% (LiB) 1 Lb CX30-5100E Pre-Fused FusionFlux®Formulation with Non-wetting agent, Lithium Tetraborate 49.75% (Li2B4O7)/ Lithium Metaborate 49.75% (LiBO2)/ Lithium Iodide 0.5% (LiI) 1 Lb CX30-5200E Pre-Fused FusionFlux®Formulation Lithium Tetraborate 35% (Li2B4O7)/ Lithium Metaborate 65% (LiBO2); 1lb Pre-Fused FusionFlux®Formulation Lithium Tetraborate 66% (Li2B4O7)/ Lithium Metaborate 34% (LiBO2); 1lb CX30-6000E Pre-Fused FusionFlux®Formulation with Non-wetting agent, Lithium Tetraborate 34.83% (Li2B4O7)/ Lithium Metaborate 64.67% CX30-6600E (LiBO2)/ Lithium Bromide 0.5% (LiB) 1 Lb PelletCups®Powdered Sample Compactors; 13mm Dia. CX30-6650E PelletCups®Powdered Sample Compactors; 32mm Dia. PelletCups®Powdered Sample Compactors; 35mm Dia. CX2513E PelletCups®Powdered Sample Compactors; 40mm Dia. CX2532E PelletCups®Powdered Sample Compactors; 45mm Dia. CX2535E Sample Storage Kit with 10 Sample Pods CX2540E Sample Pod Replacement (single pod) CX2545E Sample Storage Kit with 5 Sample Pods CX2030-10E CX2030-1E CX2030-5E Specac.com XRF Product Catalogue 2018/19 24



UK Specac Ltd, River House, 97 Cray Avenue, Orpington, Kent, BR5 4HE U.K. T: +44 76 8987 3134 F: +44 16 8987 8527 [email protected] USA Specac Inc, 414 Commerce Dr, Suite 175, Fort Washington, PA 19034 U.S.A T: +1 866 726 1126 F: +44 16 8987 8527 [email protected] www.specac.com THE WORLD'S LEADING SPECTROSCOPIC ACCESSORY MANUFACTURER