Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore Quantex Battery lead acid battery Catalogue

Quantex Battery lead acid battery Catalogue

Published by Quantex Battery, 2019-09-07 12:38:20

Description: Quantex Battery lead acid battery Catalogue
Quantex-Battery Global professional new energy technology manufacturer.
Quantex Battery provides a wide range of battery products and solutions for a variety of end-market applications
contact info:
Germany Office / Factory
Elsoffer Str. 5, Mengerskirchen, D-35794 Germany
Tel. +49 345 7789 9023

China Office / Factory
Office Address: NO594 Tianhe road, Guangzhou China
Telephone: +86 20 8709 6253
Whatsapp: +86 181 2782 0456

USA Office
Address: 8521 Leesburg Pike, Vienna, VA 2212
Telephone: +1 571 308 9197
WhatsApp: +1 571 234 1514
Email: [email protected]

Keywords: Deep Cycle Batteries,Gel battery,dry cell, agm, battery, batteries,ups backups,solar panel,PV battery

Search

Read the Text Version

I r--u··:�11�u··n-- GQuangtezxhoGuloXbuanl TGiraonupElectronic Technology Co.,Ltd Germany Office / Factory Elsoffer Str. 5, D-35794 Mengerskirchen, Germany Tel. +49 647 6418 5740 / +49 345 7789 9023 USA Office 8321 Old Courthouse Road, Vienna, VA 22182 USA Tel: +1 571 308 9197 China Office B,NO594 Tianhe road, Guangzhou China Tel: +86 20 87096253 / +86 186 2064 2285



@ompany Introduction �--��··--ru:,1un @roducts Valve Regulated Lead Acid Battery .�-u-.:..1,�1u..n... Brief Introduction Valve regulated l·ead acid batteries are designed with AGM (Absorbent Glass Mat) technology, high performance plates and Quantex Battrey LTD Subsidiary of Quantex Global Group a comprehensive Energy electrolyte to gain extra power output for common power Products company dedicated to excellence since 1984. Our superior products come backup system applicati-ons. Using high-intensity compact from our innovative research and development in our factories located in Germany battery assemble technology, to avoid the drop of active material, and China and the United-States. so the battery using life could be extended. Quantex Battery, specialized in Lead Acid battery & Gel battery research and manufacture. our Factory and develop term which located in Shaoguan City, Batterv Structure Guangdong Province. We have our own brands \"PUSTUN\". Gel battery using industry-leading Aerosol conducting medium, and pass the harsh temperature test, so the lifetime is up to 10 years. The good performance will prove the definitely reliability of battery. The integrity after-sales service ensures the good reputation of our group company. 1. Container/Cover: Made of UL94HB and LU 94V-O ABS Plastic 2. Nega1tive Plates: Use the special PbCa alloy grids, optimize the I•ftfldtiI.:.;I recombination efficiency and less gassing. �, 'JI' � 3. Separrator: Import high quality AGM separator. Our Will: � j • Build PUSTUN as the most popular brand name in battery industrial market 5',I 4. Positive Plates: PbCa grids minimize corrosion and prolong life. II� Our Strategy: E� • We survive by innovation; We build up brand by quality 5. Termiinal post: Cooper material with maximum conductivity, • We develop by brand; we see the future by development enhance the high current rapidly. Our Promise: • People oriented, you and we create the beautiful life together. l\\[1111111, 'ir,itlf11'\"' 6. Vent 'Valve: Allows the release of excess gas automatically for safety. Our Principle: I • Integrity oriented, service first. • Absolute professional, customer first, keep constantly pioneering ;.:_. L-�,��2 Lead acid battery is also named as .the following: Our Spirit: � ,�-�1I AGM battery Deep cycle battery • Innovation: It's a kind of thinking method. We dare to break through the ---- ----- -- .. 1 tradition, to explore and practice new ideas, new methods and new path. UPS bat1tery Solar battery • Profession: It's a kind of ability to work. We should focus on our work. Inverter battery Sealed lead acid battery •• Passion: It's kind of attitude. We should keep passion. • Practicality: It's a kind of working style. We should keep down-to-earth. SMF battery Rechargeable battery Storage battery Valve regulated lead acid battery

;:;;;s,iiiiValve Regulated Lead Acid Battery I A·GM Deep Cycle Battery I Battery Nominal Rated Approx.weight Dimension Model voltage capacity kg lbs Length Width Height Total Height Terminal (V) 0.66 ll.46 mm inch mm inch mm inch mm inch Type (Ah) 0.72 ll.59 20hrs/25°C 0.78 ll.72 70 2.76 1.28 2.82 70 2.76 PST4-6 4 1.65 3 L 64 70 2.76 48 1.89 101 3.98 106 4.18 Tl PST4..5-6 4.5 1.81 3 L 99 151 5.95 48 1.89 101 3.98 106 4.18 Tl PST5-6 5 17.00 37.48 151 5.95 48 1.89 101 3.98 106 4.18 Tl PST8-6 29.00 63.93 151 5.95 34 1.34 94 3.70 100 3.94 Tl PSTl0-6 10 30.50 67.24 195 7.68 50 1.97 94 3.70 100 3.94 Tl PST12-6 12 34.50 716.06 260 10.24 50 1.97 94 3.70 100 3.94 Tl PSTl00-6 100 1.33 2.93 322 12.69 170 6.70 207 8.16 210 8.27 T16 PST180-6 180 1.38 3 L 04 243 9.57 180 7.09 246 9.69 250 9.85 T19 PST200-6 200 1.70 3L75 90 3.55 178 7.01 227 8.94 230 9.06 T19 PST225-6 225 2.00 41.41 140 5.52 188 7.41 276 10.87 276 10.87 T19 PST4-12 12 4 2.20 41.85 151 5.95 70 2.76 101 3.98 106 4.18 Tl PST4.5-12 12 4.5 2.35 Si.18 151 5.95 48 1.89 102 4.02 104 4.10 Tl,T2 PST5-12 12 5 2.35 Si.18 151 5.95 51 2.01 94 3.70 100 3.94 Tl PST7-12 12 7 2.50 Si.51 151 5.95 65 2.56 94 3.70 100 3.94 T2 PST7.2-12 12 7.2 2.95 6i.50 151 5.95 65 2.56 94 3.70 100 3.94 T2 PST7.5-12 12 7.5 3.43 71.56 151 5.95 65 2.56 94 3.70 100 3.94 Tl PST8-12 12 8 3.65 8.05 151 5.95 65 2.56 94 3.70 100 3.94 Tl PST9-12 12 9 4.85 110.69 151 5.95 65 2.56 94 3.70 100 3.94 Tl PSTl0-12 12 10 5.00 11.02 151 5.95 65 2.56 111 4.37 116 4.57 T2 PST12-12 12 12 5.00 11.02 181 7.13 98 3.86 94 3.70 100 3.94 T2 PST14-12 12 14 5.50 1:2.13 181 7.13 98 3.86 94 3.70 100 3.94 T2 PST15-12 12 15 7.60 116.75 181 7.13 77 3.03 167 6.58 167 6.58 T3 PST17-12 12 17 7.80 17.20 181 7.13 77 3.03 167 6.58 167 6.58 T3 PST18-12 12 18 8.00 17.64 175 6.90 77 3.03 167 6.58 167 6.58 T3 PST20-12 12 20 10.00 2:2.05 175 6.90 77 3.03 167 6.58 167 6.58 T3 PST24-12 12 24 10.20 2:2.27 175 6.90 166 6.54 125 4.93 125 4.93 T4 PST26-12 12 26 12.00 216.46 196 7.72 166 6.54 125 4.93 125 4.93 T4 PST28-12 12 28 13.00 218.66 196 7.72 166 6.54 125 4.93 125 4.93 T4 PST33-12 12 33 13.80 31.08 197 7.76 131 5.16 155 6.11 180 7.09 T16 PST35-12 12 35 15.50 34.17 197 7.76 131 5.16 155 6.11 180 7.09 T16 PST38-12 12 38 15.50 34.17 197 7.76 166 6.54 174 6.86 181 7.13 T12 PST40-12 12 40 19.00 41.89 230 9.06 166 6.54 174 6.86 181 7.13 T12 PST45-12 12 45 19.50 4:2.99 230 9.06 166 6.54 171 6.74 171 6.74 T9 PST50-12 12 50 21.00 416.30 350 13.79 138 5.44 211 8.31 224 8.83 T12 PST55-12 12 55 25.00 5!5.11 350 13.79 138 5.44 211 8.31 229 9.02 T9/16 PST60-12 12 60 26.50 518.42 350 13.79 166 6.54 179 7.05 179 7.05 T9 PST65-12 12 65 27.50 610.63 260 10.24 166 6.54 179 7.05 179 7.05 T9 PST70-12 12 70 29.00 63.93 331 13.04 166 6.54 179 7.05 179 7.05 T9 PST80-12 12 80 29.00 63.93 331 13.04 169 6.66 211 8.31 215 8.47 T16 PST90-12 12 90 31.00 618.34 331 13.04 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 34.50 716.06 407 16.04 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 41.50 91.49 407 16.04 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 42.00 9:2.59 407 16.04 174 6.86 209 -8.23 233 9.18 T19 PSTl00-12 12 100 49.00 10)8.03 484 19.07 174 6.86 209 8.23 233 9.18 T19 PST120-12 12 120 55.00 121.25 484 19.07 174 6.86 209 8.23 233 9.18 T19 PST135-12 12 135 56.50 124.56 484 19.07 171 6.74 241 9.50 241 9.50 T19 PST150-12 12 150 60.00 132.28 522 20.57 171 6.74 241 9.50 241 9.50 T19 PST165-12 12 165 70.00 15i4.32 522 20.57 171 6.74 241 9.50 241 9.50 T19 PST180-12 12 180 522 20.57 240 9.46 216 8.51 240 9.46 T19 PST200-12 12 200 520 20.49 240 9.46 216 8.51 240 9.46 T19 PST200-12 12 200 240 9.46 216 8.51 240 9.46 T19 PST250-12 12 250 268 10.56 220 8.67 243 9.57 T19 Please note that all specifications are changed without notice.

Valve Regulated Lead Acid Battery I A·GM Deep Cycle Battery 2V Sol:ar Battery Super large capacity Using high-corrosion-resistant alloys _and unique electrolyte formula, greatly increase the battery capacity up to 3000ah. Minimal materials consumption Low resistance, using low inner resistance copper pole to ensure battery discharge safely with large current without heating. Battery Nominal Rated Approx.weight Dimension Model voltage capacity kg lbs Length Width Height Total Height Terminal (V) (Ah) mm inch mm inch mm inch Type 20hrs/25°C ,mm inch 160 6.30 PST50-2 50 2.90 6i.39 171 6.74 49 1.93 166 6.54 176 6.93 T12 171 6.74 PSTl00-2 100 5.60 1:2.35 172 6.78 71 2.80 207 8.16 227 8.94 T6 172 6.78 PSTl00-2 100 5.90 13.01 171 6.74 71 2.80 207 8.16 231 9.09 Tll 210 8.27 PST150-2 150 8.00 17.64 341 9.50 102 4.02 207 8.16 231 9.09 Tll 301 11.86 PST200-2 200 13.50 2!9.76 410 16.15 111 4.37 329 12.96 356 14.03 T20 475 18.72 PST300-2 300 18.80 41.45 475 18.72 151 5.95 330 13.00 366 14.42 T20 401 15.80 PST400-2 400 26.70 518.86 401 15.80 176 6.93 329 12.96 366 14.42 T20 491 19.35 PST500-2 500 31.00 618.34 710 27.97 172 6.78 331 13.04 366 14.42 T20 710 27.97 PST600-2 600 38.00 83.77 175 6.90 331 13.04 366 14.42 T20 PST800-2 800 53.00 11l6.84 175 6.90 330 13.00 365 14.38 T20 PSTl000--2 1000 63.00 138.89 175 6.90 330 13.00 356 14.03 T20 PST1200-2 1200 74.00 16i3.14 175 6.90 330 13.00 356 14.03 T20 PST1500-2 1500 101.00 222.66 351 13.83 342 13.47 369 14.54 T20 PST1800-2 1800 120.00 26i4.55 351 13:83 342 13.47 369 14.54 T20 PST2000-2 2000 132.00 29)1.01 351 13.83 343 13.51 369 14.54 T20 PST2500-2 2500 165.00 36i3.76 •352 13.87 342 13.47 369 14.54 T20 PST3000-2 3000 195.00 429.90 352 13.87 342 13.47 369 14.54 T20 Please note that all specifications are changed without notice.

GEL Battery ruS,iiii I Our gel battery is manufactured with special separator and colloidal or foamed silica. The batteries use silica gel to immobilize the electrolyte inside the battery. Excellent Performance A.High efficiency discharge: sealed reaction efficiency rate more than 99.99%. B.Low rate of liquid loss: Iiquid loss ratei is half lower than adsorbed type battery. Effectively alleviate the electrolyte early dry. C.Low self discharge: storage with power for two years among temperature 25°C is possible. Storage tt:ime is 4 times longer than adsorbed type battery. Deep cycle longer life A.Longer life: 12 years design life, saving expenses of replacement. B.The deep discharge cycles is increased by 50% as compared with the AGM battery. Strong adaptability & recover ca. pabill 1ity A.High adaptation to the environment: able to work in -40°C-60°C temperature range. B.Excellent recovery capability after over-discharge: over discharge to \"O\" V, battery still have a good recovery ability. Discharge under lCA for 21 days, battery recover capacity ability is up to 100% recovery. Battery Nominal Rated Approx.weight Dimension Model voltage capacity kg lbs Length Width Height Total Height Terminal (V) ,mm inch mm inch mm inch mm inch Type (Ah) 20hrs/25°C 175 6.90 196 7.72 PST24-12 12 24 7.60 116.75 197 7.76 166 6.54 125 4.93 125 4.93 T4 10.00 22.05 230 9.06 PST33-12 12 33 12.00 216.46 230 9.06 131 5.16 155 6.11 170 7.09 T9, 16 15.50 34.17 350 13.79 PST38-12 12 38 15.50 34.17 260 10.24 166 6.54 174 6.86 181 7.13 T12 19.50 42.99 260 10.24 PST50-12 12 50 21.00 416.30 331 13.04 138 5.44 211 8.31 229 9.02 T9, 16 25.00 5!5.11 331 13.04 PST55-12 12 55 26.50 518.42 331 13.04 138 5.44 211 8.31 229 9.02 T9, 16 27.50 60.63 407 16.04 PST65-12 12 65 29.00 63.93 407 16.04 166 6.54 179 7.05 179 7.05 T9 29.00 63.93 407 16.04 PST70-12 12 70 31.00 618.34 484 19.07 169 6.66 211 8.31 215 8.47 T16 34.50 716.06 522 20.57 PST80-12 12 80 42.00 9:2.59 520 20.49 169 6.66 211 8.31 215 8.47 T16 60.00 132.28 PST90-12 12 90 70.00 15i4.32 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 173 6.82 213 8.39 233 9.18 T19 PSTl00-12 12 100 174 6.86 209 8.23 233 9.18 T19 PSTl00-12 12 100 174 6.86 209 8.23 233 9.18 T19 PST120-12 12 120 174 6.86 209 8.23 233 9.18 T19 PST150-12 12 150 171 6.74 241 9.50 241 9.50 T19 PST200-12 12 200 240 9.46 216 8.51 240 9.46 T19 PST250-12 12 250 268 10.56 220 8.67 243 9.57 T19 Please note that all specifications are changed without notice.

Front Terminal Battery ruS,iiii I General Featu res: • Long Service Life • Nonspillable • Solid Copper Terminals • Sealed and Maintenance- free Operatirnn • Tank-formed Plates • High Quality and High Re liability • Computer-aided Design and Manufacturing • Exceptional Deep Dischar ge Recovery • Low Self-discharge Battery Nominal Rated Approx.weight Dimension Model voltage capacity Length Width Height Total Height Terminal (V) (Ah) mm inch mm inch mm inch Type kg lbs mm inch 20hrs/25°C 227 10.9 227 10.9 PST50-12 12 50 16.50 316.40 563 22.18 106 4.17 221 8.7 229 9.02 T17 17.50 318.59 563 22.18 PST55-12 12 55 25.00 5!5.10 562 22.13 106 4.17 221 8.7 229 9.02 T17 28.50 6:2.84 508 20.0 PST70-12 12 70 25.00 5!5.00 508 20.0 115 4.53 188 7.41 188 7.41 T17 31.00 618.30 560 22.0 PST75-12 12 75 32.50 71.60 395 15.6 115 4.53 188 7.41 188 7.41 T17 34.50 716.10 436 17.2 PST80-12 12 80 34.00 74.90 436 17.2 114 4.49 188 7.41 188 7.41 T17 39.50 87.10 551 21.7 PST90-12 12 90 41.00 87.10 548 21.6 110 4.33 223 8.78 238 9.37 T17 45.00 9!9.20 551 21.7 PSTl00-12 12 100 45.00 9!9.20 551 21.7 110 4.33 223 8.78 238 9.37 T17 45.00 9!9.20 546 21.5 PSTl00-12 12 100 46.00 9!9.30 546 21.5 125 4.92 228 8.98 228 8.98 T17 53.80 118.4 560 22.0 PST105-12 12 105 57.00 1:25.6 546 21.5 110 4.33 286 11.3 286 11.3 T17 57.00 1:25.6 PST120-12 12 120 60.00 135.0 108 4.25 317 12.5 317 12.5 T17 PST125-12 12 125 108 4.25 317 12.5 317 12.5 T17 PST150-12 12 150 110 4.33 287 11.3 287 11.3 T17 PST150-12 12 150 105 4.13 316 12.4 316 12.4 T17 PST150-12 12 150 105 4.13 287 11.3 287 11.3 T17 PST160-12 12 160 110 4.33 288 11.4 288 11.4 T17 PSTl75-12 12 175 125 4.92 317 12.5 325 12.8 T17 PST180-12 12 180 125 4.92 317 12.5 325 12.8 T17 PST180-12 12 180 125 4.92 317 12.5 317 12.5 T17 PST200-12 12 200 125 4.92 317 12.48 323 12.72 T17 Please note that all specifications are changed without notice. ••

Tubular Flooded Battery ruS,iiii I Tubular flooded b attery Opzs Series Valve Regulated Lead Acid batteries are designed with a combination of die-casting Tubular positive framework and superfluous electrolyte technologies to offer a very high lever of reli ability and a llong service life. Opzs batteries used special filter and proof design to en sure no acid 1fog runs over and burning proof, and also convenient examine and ma intenance. Characteristics 1.Floating design life time u p to 20 years.. 2.Designed cycle life more t han 600 times at 100% deep discharge at 20°C ambient temperature. 3.Tubular positive plate with prolonged cycle life. 4.Explosive-proof with speci al designed vrented plug. 5.Dry charged package and delivery ensuire longer shelf life. 6.Ensuring sufficient electro lyte for the b,attery discharge. Nominal Rated Approx.weight Dimension voltage capacity Battery kg lbs Length Width Height Total Height Terminal Model (V) (Ah) mm inch mm inch mm inch mm inch Type 20hrs/25°C 13.2 2!9.11 16.2 3!5.72 103 4.06 OPzS2-200 200 19.2 4:2.34 124 4.88 206 8.11 354 13.94 409 16.1 T20 19.4 4:2.76 145 5.71 OPzS2-250 250 23.4 !51. 124 4.88 206 8.11 354 13.94 409 16.1 T20 27.4 60.42 145 5.71 OPzS2-300 300 33.9 74.75 166 6.54 206 8.11 354 13.94 409 16.1 T20 45.3 9)9.9 145 5.71 OPzS2-350 350 55.5 1:22.4 191 7.52 206 8.11 470 18.5 525 20.67 T20 65.8 145.06 233 9.17 OPzS2-420 420 87 1!91.8 275 10.83 206 8.11 470 18.5 525 20.67 T20 123 271.2 275 10.83 OPzS2-500 500 142 313.1 399 15.71 206 8.11 470 18.5 525 20.67 T20 179 3!94.7 487 19.17 OPzS2-600 600 576 22.68 206 8.11 645 25.39 700 27.56 T20 OPzS2-800 800 210 8.27 645 25.39 700 27.56 T20 OPzS2-1000 1000 210 8.27 645 25.39 700 27.56 T20 OPzS2-1200 1200 210 8.27 645 25.39 700 27.56 T20 OPzS2-1500 1500 210 8.27 795 31.3 850 33.46 T20 OPzS2-2000 2000 214 8.43 771 30.35 826 32.52 T20 OPzS2-2500 2500 212 8.35 771 30.35 826 32.52 T20 OPzS2-3000 3000 212 8.35 771 30.35 826 32.52 T20 Please note that all specifications are changed without notice. •

Tubular GEL Battery ruS,iiii I Tubular GEL Battery · YENTPLUP TERMINAL Opzv Series Valve Regulated Lead Acid batte..-ies are designed with a proven combination of GEL and Tubular technologies to offer a very high level of reliability. Opzv batteries • CELL.COVER benefit from an optimized plate design wlhich gives capacities in excess of the DIN P05111YE·ELECTRODE standard values. In addition, this series offe..-s both a longest float life and a high cycle NEOArlVE·ELECTllODE life in widely industrial field. SEPARATOR Characteristics CELL-CONTAINER 1.Floating design life time up to 20 years, in the operation of normal float charging, capacity keeps stable, attenuation rate s1tays low. 2.Excellent recover ability of cycling and deep discharge, more than 800 times cycle life at 100% deep discharge, improve the system reliability effectively. 3.Gel electrolyte 4.Low self-discharge <50% of rated capacity in 2 years at 20°C ambient temperature. 5.No internal short circuits possible due to the gel structure. 6.Easy install using cable connectors with iinsulated terminal covers. Nominal Rated Approx.weight Dimension voltage capacity Battery kg lbs Length Width Height Total Height Terminal Model (V) (Ah) mm inch mm inch mm inch mm inch Type 20hrs/25°C 20 414.1 24 Si2.9 103 4.06 200 29 6i3.9 124 4.88 206 8.11 354 13.94 380 14.96 T20 31 6i8.4 145 5.71 250 36 719.4 124 4.88 206 8.11 354 13.94 380 14.96 T20 42 9l2.6 145 5.71 300 50 110.3 166 6.54 206 8.11 354 13.94 380 14.96 T20 59.5 131.2 145 5.71 350 68 149.9 225 8.86 206 8.11 470 18.5 496 19.53 T20 82 1180.8 191 7.52 420 97 213.9 233 9.17 206 8.11 470 18.5 496 19.53 T20 120 2164.8 275 10.83 500 160 3!52.8 275 10.83 206 8.11 470 18.5 496 19.53 T20 200 1441 399 15.71 600 240 5:29.2 487 19.17 206 8.11 645 25.39 671 26.42 T20 576 22.68 700 206 8.11 470 18.5 496 19.53 T20 800 210 8.27 645 25.39 671 26.42 T20 1000 210 8.27 645 25.39 671 26.42 T20 1200 210 8.27 645 25.39 671 26.42 T20 1500 210 8.27 795 31.3 821 32.32 T20 2000 212 8.35 772 30.39 797 31.38 T20 2500 212 8.35 772 30.39 797 31.38 T20 3000 212 8.35 772 30.39 797 31.38 T20 Please note that all specifications are changed without notice.

l�\"'U..:.J.I..U..f..f. Application -- UPS App,/ication Telecommunications/Communication system ,�-u--:..,..�1u··n-- UPS(Uninterruptible Power Supply): During the telecommunication and communication system, battery is an important part of it just as a backup DC power supply. It ensures to provide a safe, stable, reliable power for the system. It' s working theory is similar with UPS. An electronic device connected between the utility power and electric consumers, comprising generally of filters, rectifier, battery, DC/AC inverter, transfer switch and In the system, batteries work in parallel with the rectifier, and they act as two roles: associated circuits. The UPS is intended to provide clean undisturbed stabilized AC Functio1n A: when AC power failure, automatic load to the DC power supply to ensure uninterrupted power supply; voltage, within strict amplitude and frequency limits, to protect the consumer from Functio1n B: when normal AC power supply, it can be equivalent to a sufficiently large capacitor filtered each harmonic output of any utility power disturbances and irregularities, including outages for a limited time dictated by the capacity of the battery bank. The term UPS refers generally to AC the rectifier, keep DC purity. static systems, other types include DC and Rotary UPS. The larger· capacity of battery, the higher purity of DC. Therefore, the stability of battery and the actual capacity of battery during • Normal work By-pass switch dischargimg can be supplied to the load is very important. It influences on the safty operation of the device. 8 ....., ..Surge voltage 1-/1 Filter Rectifier Inverter Load ----+ Daily clheck when the batteries are using in the system Mains on load 1. Check the voltage ·of batteries 2. Check each connection if loose o.r corrosive Battery 3. Check·the battery case if leaky and transmutative 4. Check around the valve and column if acid or mist Electric supply failure or overload, battery discharging: spill.out 1. When the AC input voltage exceeds the UPS allowed tolerance range or electric power failure, the rectifier I charger automatically 5. Attention the environment temperature 6. Check the battery management parameters with stop working. Battery pack immediately take over and discharge without interruption, continue to supply power to the load through the inverter. switching power supply periodically. 2.UPS will keep running until the battery discharge time is terminated, or when the electricity back to normal operation mode. Recommend Battery series -- Valve regulated lead acid battery ••

�--��··-- Application -- Solar Street Lighting System Application -- S·olar h.ome system ,�-u--:.,.�1u··n-- l\"'U:JIUn Solar street lighting system is a set of independent distributed power supply .}solar panels Solar panels system composed of solar lights. No need of excavation for wiring construction, solar rack and the installation is very easy. No need of consume electricity and transmission Mounting system system. It saves energy and good to environment. Pustun batteries as part of the Lamp post system, widely be used in off grid road lights, outdoor billboards, and bus station Light platform applications. '-.. Solar street lighting system works description Foundation Solar bolt Connect passageway batteries Solar street light in the daytime under the control of the intelligent controller, solar panels after exposure to sunlight, absorb light and convert solar energy into electricity, solar modules during the day to charge the battery, the battery pack to provide power at night to LED powered light source to achieve the illumination function. Led light + Solair power is ideal for providing energy for home system. To make use of this free energy you can employ solar power solutions at home. This will not only cut down power bills but also help you contribute \\C to a green world. A solar power home system includes 1the use of solar cookers, solar heating system, solar lighting systems, solar dryers etc. Families have started employing solar energy as a power solution at 3· their hoimes. Families have started employing solar energy as a power solution at their homes. \\C Solar power home systems have many advantages apart from being cost-effective and environment- friendly.. They are low on maintenance thus saving your time and effort . Also, solar systems give you a Solar battery Solar modules return o,n investment very soon, thus making the systems free some time.

,�-u..:.,.1..u..n... Application -- Large solar power generation system Application -- Solar & Wind hybrid power generation system .�-u--:.,.�1u··n-- Conifiguration diagram of Solar and wind power generation system AC load Solar panels Wind generator Solar PV modules absorb light and convert solar energy into electricity DC power. Battery connect together become battery Ma1ny areas have abundant solar and wind resources. Meantime.there may have the problems with shortage of energy and pack, later the inverter convert AC to DC power, finally distribute power every applications. environmental pollution. Therefore.we can change the energy structure then help to improve the environment. Both of solar and wind energies are influenced by the seasons, the temperature and the environment strongly. They are two kinds of unstable energies, These design factors should be considered in the solar power generation system. but also a1re complementary. That's why they can improve energy efficiency and economic benefits. 1. Consider the place where solar photovoltaic power generation system using as well as the local solar radiation The system has three modes of operation based 011 the changes of wind and solar energy. 2. Consider the load power 3. Consider the output voltage of the system and the use of a DC or AC power Mode 1: Wind turbines supply power to the load alone 4. Consider how many hours that the system works per day Mode 2: solar panels supply power to the load alone 5. If there is no sunlight in rainy weather, how many days should the system continuously supply power Mode 3: wind turbines and solar panels supply power to the load together

,�-u..:.,.1..u..n... Application -- Customers ' Cases Application -- Customers ' Cases .�-u--:�11�u-·n. .

�--��··-- Producing Progress Producing Progress .-u:11un�1111��-IIAl/l l\"'U:JIUn acid filling glue sealing plate packing

l�\"'U..:.J.I..U..f..f. Appendix I -- Battery Performance Characteristics Appendix II -- Terminals .�-u--:�11�u-IJnAl/l Curves of charging characteristics Curves of dischar e characteristice Terminal Unit: mm l ! Charging characterisitic 2.30 1-+--+--+-+-++++++----+--+--++-<>----+-+-+-+-+++-1+---+-+-++-i-++-<-+----I ........ ..... TO Te_ rminal Tl Terminal 2.20 1--+----+-+--1++++++----4---+--++-lf---++-++l++-l+-----+-H+-l-++-l+-----l T4 Terminal i ru:11un f ! �-�-·-•• _• ••_••-\"'�P_•• _o._2a_-_•• --•• __<2_ts __l _� 120 �:;� �:=::�:�::=�=:��-� J:-;-;;:::::=��::::::�:�� ���DU§§;:ffl�:ff:S!!EtE'.:EBIITDCJ I) 1 .90 l=l=-+-\"1::--l++tt++--�--l<--++Pk---+\"-'k-++++N+--1-+l+++N+----l 1 .80 f-+-++-t--PH;Ht----l--\\l-\\-+t-11-'\\,---t-t\\-++l+t-lll::-:-:-=t:-Ht=!Msl�--l 1 .5o 1--+----+-+--+++++++I-\\\\--l,..,-'f-'�H!-- ++---+-+++++++1--1-H+++1-++-----1 1 .40 t1---++----++--++---t1+-++++++t+++f-'2=-'\"'_-.1, _-,1+=---++---+++H+>-------++--++-++-+++t+++++-1t-t----+1--tHt++-+t+-tHt-+i+-------1t 1 .30 0 1 2 4 6 8 1 0 20 40 60 2 4 6 8 1 0 20 50 1 00200 T2 Terminal T3 Terminal �min >-----tE------<h>--------i� Discharge time Curves of float voltage and temperature Curves of discharge capacity and temperature Float voltage 110Capacity (%) 1001----+--+--l--+--+--h•��:t:=:=i 15. 6 1---1---t----t>-----t---+----t--t- - - +----+--I T6 Terminal T9 Terminal TlO Terminal = � :,x 90t----t--T\"\"\"'c:-t--7\"\"��\"\"'P\"\"----t----t--.,..._---t 15. 0 t----<,��- -�---+--+---+----+-+----+-----+------< 80t---+-,t,'---,,1'�-+-7\"-t------a�--+-----ir---+--t 14. 41---+-��ls::::--+-+----l--+-+---+---l 70 .........._,...,.______----<.......-+---+---+-----t---+---t 60 ........--+----------.>----+---+---+-----t---+---t 13. 8 \"�r:::::- 50....-------...c.--1 _____---1,__-+---+----i _____________-:_��t-- 40 ,.___.__........__.__.__.___.___.____....__.___, -=13. 2 -20 -15 -10 -5 0 5 10 15 20 25 30 12. 6 1------+---+----t>-----+---+----+---+-----+---I Ambient temperature ('C) 12. 0 �--+---+----I>----+---+----+--�---+-� -30 -20 -10 10 20 30 40 50 t Ambient temperature Tll Terminal T12 Terminal T16 Terminal Curves of self-discharge and storage time Curves of c cle life �� ��JOO -- '\\0 -120 --\"�90 i:�...... --r--.. r--i---� 100 r-- I--,__ \"\"\" --� 80\\ '\\[',..,_........ -i--- T19 'JI'erminal T20 Termina:l T32 Terminal � \"\"\"\"'g-70 .\\ r-..... 5t � --------.., • \"(.) ........ JO'>IOOO \\ r---... -i-- 100%000 50%000 \"\"'- ln\"I \\\\ ........ I\\ \"' �60 \\ \\. ' \" �B\"5'C-50 ........ '\\.. \\ ...... ......I.'-... 20 45\"( 40 lO\"C ........ 0 200 400 600 800 1000 1200 1400 1600 20°( Number of cycles(timcs) 40 1 2 3 1 5 6 7 8 9 10 11 12 13 11 15 16 17 Storage time (months)

Appendix Ill -- Service Progress With Solar Battery Appendix IV-- Operation And Maintenance ,�-u--:.,.�1u··n-- Batteiy failure occured For maintenance free battery, it' s free maintenance in the operation. But we still need to use it in proper operation to keep ,the long life time of battery. Battery voltage measonng Ba1ttery Installation __I (1) !Lay the battery with up-down direction instead of put it inverted in any case. ' Replace battery (2) !Abnormal vibration or shock is not allowed. (3) IDo insulate when installation. Failure recovery (4) !Make the batteries ventilated and gapped. (5) IDo not mixed up different brand and different manufacturing date batteries. (6) Separate the batteries from organic solvent. Q The Ambient Temperature Amlbient temperature is an important factor for the battery operation. When the temperature is too high, battery plate corrrosion will be increased, meanwhile absorbing more moisture. When the temperature is too low, the battery will not be full charged. All these factors will affect the battery life. Therefore we suggest the working temperature is around 25°C. O The Charge and Discharge Current ................................................................................................................................................... Batttery charge and discharge current uses the concept C, the actual value of C is related to the capacity of the battery. For example, .a lOOAH battery: lC=lOOA. Charging current rate is around O.lC; not larger than 0.3C. Discharge current is bet,ween in the range of 0.05-3C. U, Ch,arging Voltage After the battery is full charged, the float voltage is around 13.7V. If the charging voltage is too high, the battery is oveircharged, otherwise the battery is not charged fully. Charging voltage is abnormal, it may be caused by the battery cornfiguration error, or controller failure. Do not choose the bad quality controller. O The Depth Of Discharge (DOD) DOID is also an important factor for the battery lifetime. Deeper of battery discharge, fewer cycle times of battery. So !battery should avoided from deep discharge. fD Regular Maintenance Batttery should be regular checked in every period after used. Such as check its outlook, measuring the average voltage of each battery, etc. Charge the battery to full at the first use or after long term storage.


Like this book? You can publish your book online for free in a few minutes!