CBBT 0.75 Sq.mm T3 Siechem WWirieress&&CCaabbleless Application Product Construction Technical Data ü Low-tension electric wire for automobiles. ü Conductor : Soft-annealed electrolytic bare ü Temperature Range : -400C to + 1250C ü Used in Motorcycles and other motor vehicles for Copper according to ISO 6722 ü Specification : MS 90034 & ISO 6722-1 starting, charging, lighting, signal and instrument ü Cable construction according to C - Temperature Class C panel circuits. ISO 6722 Class C(Thin wall) B - Asymmetrical B - Bare Copper ü Insulation : AX-125 (T3) T - Thin Wall ü Colour : As per customer order. ü Single core, Single layer insulation Features CBBT (T3) ISO ISO IATF OHSAS 9001 14001 16949 18001 ü Flame retardant ü Highly resistant against acids, lyes, Petrol and diesel. ü Heat resistance ü Halogen free Conductor Construction Insulation Cable Max. Current Wall Thickness Conductor Carrying Part Nominal No. of Diameter of Conductor Overall Weight Resistance Capacity Standard Number Cross- Strands Single wire Diameter Nom. Diameter Approx. Length* Section Max/Min. at 200C Amps Y80205XX * nos. max. Max. mm 12 mtrs Y80206XX mm2 12 mm 0.25 mm kg/km Ω/km 15 500 Y80208XX 0.35 16 mm 0.28 1.20/1.40 5 20 500 Y80210XX 0.5 24 0.21 0.9 0.30 1.40/1.60 7 54.4 24 500 Y80213XX 0.75 32 0.21 1.1 0.30 1.70/1.90 10 37.1 30 500 Y80214XX 30 0.21 1.3 0.30 1.90/2.10 11 24.7 37 500 Y80216XX 1 28 0.21 1.5 0.35 2.20/2.40 17 18.5 42 500 Y80217XX 1.5 50 0.26 1.8 0.35 2.50/2.80 23 12.7 49 500 Y80219XX 2 44 0.31 2.0 0.40 2.70/3.00 25 9.42 58 500 Y80221XX 2.5 56 0.26 2.2 0.40 3.10/3.40 35 7.60 66 500 Y80223XX 3 65 0.31 2.4 0.40 3.40/3.70 43 6.15 75 500 Y80225XX 4 84 0.31 2.8 0.40 3.90/4.20 54 4.71 92 500 Y80227XX 5 50 0.33 3.1 0.40 4.00/4.30 59 3.94 107 500 Y802A11XX 6 80 0.31 3.4 0.60 4.60/5.00 82 3.14 122 500 Y80228XX 8 96 0.46 4.3 0.60 5.30/6.00 2.38 142 500 Y80256XX 10 126 0.41 4.5 0.65 5.80/6.50 105 1.82 158 500 Y80230XX 12 152 0.41 5.4 0.65 6.40/7.20 135 1.52 184 500 16 196 0.41 5.8 0.65 7.00/7.80 167 1.16 500 20 0.41 6.9 7.90/8.70 208 0.995 Orange - 10 25 0.41 7.2 245 0.743 Pink - 21 Violet - 11 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 ü Current Carrying capacity given is for the maximum conductor operating temperature of 1250C and ambient air temperature of 400C. ü * Other length as per Customer order. Catalogue No Y802 Siechem Wires & Cables Meet EU RoHS Directive Lead Hg Cd Cr6+ PBB PBDE Free Free Free Free Free Free www.siechem.com 113 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Search
Read the Text Version
- 1 - 1
Pages: