Home Explore ECM601 digital panel meter brochure

ECM601 digital panel meter brochure

Published by Umair Siddiqui, 2021-04-08 08:53:21

Description: ECM601 digital panel meter brochure

Search

Read the Text Version

ECM600 Series Digital Panel Meters ECM625 ECM603/603H ECM601 Power Quality Building Automation Distribution Automation Energy Management System E-Power Technology Ltd. http://www.e-powertech.ca

ECM601 Single-phase Digital Panel Meter Description The ECM601 series single phase digital panel meters are suit for 220V (L-N)/ 380V (L-L) low voltage system. The device is designed for monitoring and displaying electric parameters include voltage, current, active power, reactive power, power factor, frequency, active energy. Feature Application • Sampling AC data in single phase system, transport • Control panels data via RS485 communication • Low voltage switchboard • Energy management system • High brightness LED panel for local operation • Power quality analysis • Optional single parameter measure or integrated measure • External CT programmable • RS485 communication/ MODBUS protocol Performance Index • Overload capability: 120% of rated current or voltage • Standard: DLT721-2000, IEC61000-4 • Communication: • Accuracy: RS485 port/ MODBUS protocol Voltage: 0.5% Baud rate: 4800/ 9600bps Current: 0.5% Address: 1~ 247 Power: 1.0% Active energy: class 1 • Analog output load resistance:400 • Power loss 2VA • Relay output: 250VAC/5A, 30VDC/5A • Power frequency withstand voltage: • Status input: external power supply AC2kV/ min. ~1mA Input--Output--Power • Electrical fast transient/burst immunity test: • Insulation resistance 50M IEC61000-4-4, Level 4 • Impulse withstand voltage: • Surge immunity test: 5kV (peak), 1.2/50uS IEC61000-4-5, Level-3 • Input range: • Electrostatic discharge immunity test: IEC61000-4-2, Level 3 Current: AC 0~5A Voltage: 0~220VAC • Operating temperature: -40~ 70 Frequency: 50/ 60Hz • Storage temperature: -50~85 • Humidity: 5~95%, non-condensing

Dimension and Installation Order Information ECM601-- -- (Users should provide the current input when place order.) : Module Structure U Voltage I Current F Frequency P Voltage + Current + Active Power W Voltage + Current + Active Energy Z Voltage + Current + Active Power + Reactive Power + Power Factor + Frequency + Active Energy : Auxiliary Function A One 4-20mA Analog Output S Two Status Inputs R One Relay Alarm Output C One RS485 Communication Note: Auxiliary function A-and R can’t be selected together.

Typical Connection 34 D 12 Primary Connection D Secondary Connection Secondary Connection C C Power Status Power Supply Input Supply Status B Input To Control Loop B A Current Current Relay Signal Signal Output Voltage Communication Voltage Signal CommunicationSignal A 34 Notes: 1. Operating power supply: 85~265Vac or 80~300Vdc. 2. Auxiliary power of status input: 220Vac±25% 220Vdc±25% 3. Terminals of relay output and analog output are coincident. 4. Those unmarked terminals are invalid. 12