NEW 4,6,8,16,24,30 APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro

Discover the evolution of two-stage rotary vane vacuum pumps. Built to last. Born to perform. And designed to simplify your work. Meet the robust vacuum pump series – CRVpro. COOL RUNNING INTERNAL SURFACE PROTECTION LARGE OIL CAPACITY Enhanced air flow allows the Inside surface of the oil case has a Chemical vapors that sublime pump to run 10°C cooler than PTFE coating and the outer surface from the foreline cold trap into standard rotary vane pumps. of the pumping module has a black oxide the pump oil are more diluted The lower temperature leads to coating. Both coatings act to slow metal due to the larger oil capacity. reduced chemical activity within corrosion and, when coupled with This minimizes the rates of oil the pump and slows down rates foreline traps, extend service interval. breakdown and reduce chemical of oil consumption. attacks within the pump. HIGHEST RELIABILITY LONG PRODUCT LIFESPAN LESS MAINTENANCE EXTENDS SERVICE INTERVAL

YOUR BENEFITS Extended oil change intervals for less maintenance costs Highest reliability for stable operation and long product lifespan Less oil consumption by cool running operation Reduced risk of chemical attacks and oil breakdown by diluting chemical vapors Extended usability of oil due to high with a larger oil chamber dilution effect by a larger oil chamber Slowing down corrosion by cool running operation Provides a measure of protection from sublimed chemical vapors with coating on pump module and oil case 1 34 7 25 6 1 LOW NOISE LEVEL 4 GAS BALLAST WITH 6 SIZED TO FIT YOUR APPLICATION Exceptionally quiet for INERT GAS OPTION Modern and compact design undisturbed work. Minimizes entrained to fit different applications and performance requirements. chemicals in pump oil. 7 DUAL VOLTAGE MOTOR 2 FORCED OIL LUBRICATION Protects pump from condensable liquids from Dual voltage motors meet IP54 Ensures moving parts are bathed in application such as water, standard. Motors of CRVpro 4,6,8 fresh oil. Equilibrates temperature, acetyl nitrile, etc. are switchable from 115V to minimizes oil breakdown, and 240V for global use excluding 100V and 200V pump versions. prolongs mechanical life. 5 cUL AND CE Each pump includes power cord suitable for country use. CERTIFICATION 3 ANTI-SUCK BACK VALVE Compliance with local Prevents oil from being sucked regulations and safety into application in the event of a directives for safety power failure. operation.

APPLICATIONS LSICNHELENK FDRREYEEZRE CVAOCNUCUEMNTRATOR HVAC VOAVCEUNUM GLOVE BOX SMPAESCSTROMETER IANPDPULISCTARITIAOLNS CRVpro 4/6 CRVpro 4/6/8 CRVpro 6 CRVpro 8 CRVpro 8 CRVpro CRVpro CRVpro 8/16/24/30 16/24/30 4/6/8/16/24/30 TECHNICAL DATA PARAMETER UNIT CRVpro 4 CRVpro 6 CRVpro 8 CRVpro 16 CRVpro 24 CRVpro 30 Free air displacement – @ 50 Hz m3/h (L/min) 4 (67) 6 (100) 8 (133) 18,3 (305) 26,2 (436) 33,1 (551) – @ 60 Hz CFM (L/min) 2,8 (78) 4,2 (118) 5,6 (158) 12,8 (363) 18,3 (519) 22,1 (627) Pumping speed – @ 50 Hz m3/h (L/min) 3,8 (63) 5,1 (85) 7,3 (122) 16,8 (280) 24 (400) 29 (483) – @ 60Hz CFM (L/min) 2,7 (77) 3,7 (105) 5,1 (143) 11,9 (336) 17 (480) 20,5 (580) Ultimate pressure – Without gas ballast partial mbar (Torr) 5x10-4 (4x10-4) 3x10-4 (2x10-4) – Without gas ballast total mbar (Torr) 3x10-3 (2x10-3) – With gas ballast total mbar (Torr) 2x10-3 (1.5x10-3) 6x10-3 (5x10-3) Connection flanges Ambient temperature DN 7x10-2 (5x10-2) 25 KF Noise level (50 Hz) °C Oil capacity dB (A) 16 KF 55 Motor speed ml 2200 Motor power rpm 50/60 Hz 10 – 40 1450/1750 Weight kW 50/60Hz 0,7/0,85 Dimensions, L x W x H kg 50 38,5 mm 569/206/289 1150 1000 2400 2100 39,5 1450/1740 0,37/0,4 21 22 22,5 37 463/157/230* * Without handle ORDERING INFORMATION DESCRIPTION CRVpro 4 CRVpro 6 CRVpro 8 CRVpro 16 CRVpro 24 CRVpro 30 220-240 V / 50 Hz; 230 V / 60 Hz, 1 phase motor 3042-00 3062-00 3082-00 3162-00 3242-00 3302-00 with line cord EU-plug (CEE 7/4), line cord UK-plug (BS1363), line cord US-plug (Nema-5) S3077-99 S3078-99 S3079-99 S3193-99 S3194-99 S3195-99 S3080-99 S3192-99 Service kit Seal kit Every pump is supplied complete with Directorr™ Premium vacuum pump oil, centering rings, clamping rings and motor overload protection. Ready for use after oil filling. Motor versions (e.g. explosion proof, 3-phase) upon request.

PERFORMANCE INTAKE PRESSURE (torr) 10-4 10-3 10-2 10-1 1 10 102 750 1000 100 10PUMPING SPEED (m3/h) PUMPING SPEED (l/min ) 100 1 10 0.1 1.7 10-4 10-3 10-2 10-1 1 10 102 103 Without gas ballast With gas ballast INTAKE PRESSURE (mbar) COMPLETE PACKAGES & ACCESSORIES PACKAGES (PUMP + ACCESSORIES) DESCRIPTION CRVpro 4 CRVpro 6 CRVpro 8 CRVpro basic package 330071 330072 330073 CRVpro with oil mist separator AKD 16, 2-way ball CRVpro measurement package valve, hose connector DN 16KF-10/8 mm, vacuum 330074 330075 – hose (1,5 m), oil change set CRVpro with digital vacuum gauge PIZA 111 cr-gold, oil mist separator AKD 16, 2-way ball valve, T-piece, hose connector DN16KF-10/8 mm, vacuum hose (2,5 m), oil change set ACCESSORIES DESCRIPTION ORDER NO. CRVpro 4,6,8 CRVpro 16,24,30 Vacuum Directorr™ premium vacuum oil, 1 liter 800995-01 pump oil On inlet Directorr™ premium vacuum oil, 5 liter 800995-05 On outlet Inlet condenser (AKS 16) 320016 (AKS 25) 320018 Vacuum hose Nitrogen (dry ice) cold trap DN10 1420H-14 – Oil change set Application Oil mist separator AKD with large glass jar for easy capture and (AKD 16) 320015 (AKD 25) 320017 and vacuum horizontal arrangement alongside the pump CRVpro 16 only control kit Economic oil mist filter OME with exchangeable cartridge (plastic) (10/16) 700010 (30/25) 700012 Standard exhaust filter with good capture of oil mist (metal) U1417P-8 U1417P-11 Professional exhaust filter with excellent capture of oil mist and U1417C U1417D pump noise reduction (metal) 330060 Hose adaptor kit with hose connector, red rubber vacuum hose 1,5 m and clamps (DN16) 710755 (DN25) 710756 Stainless steel vacuum hose, 1,5 m 340011 Oil drain valve, funnel (DN16) 330031 (DN25) 330032 Freeze dryer adapter kit, with oil mist separator AKD, 2-way ball (DN16) 330053 (DN25) 330054 valve, PVC vacuum hose (1,5 m) and hose connector DN 16KF / DN 25KF, hinge clamp ring and centering ring Vacuum control kit, digital vacuum gauge MRV 100 with PIZA 111 cr-gold, T-piece, solenoid valve, hinge clamp ring and centering ring

GLOBAL CONTACT Contact us EMEA AMERICA Gardner Denver Thomas GmbH Gardner Denver Thomas Inc. Am Vogelherd 20 1601 Feehanville Drive 98693 Ilmenau Suite 550 Germany Mt. Prospect, IL 60056 USA Phone: +49 3677 604 1000 Fax: +49 3677 604131 Phone: +1 847 676 8800 Email: [email protected] Fax: +1 847 6778606 Email: [email protected] ASIA PACIFIC Gardner Denver Welch GLOBAL HEADQUARTERS Room 2206, Qiangsheng Mansion Gardner Denver Thomas GmbH No. 145 Pujian Road Livry-Gargan-Str. 10 200127 Shanghai 82256 Fürstenfeldbruck China Germany Phone: +86 21 51860238 Phone: +49 8141 2280 1000 Fax: +86 21 50396221 Fax: +49 8141 8892136 Email: [email protected] Email: [email protected] www.welchvacuum.com www.welchvacuum.de APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! © Gardner Denver Thomas GmbH. All rights reserved. 07/2017. www.welchvacuum.com/crvpro

APPLIED VACUUM TECHNOLOGY Vacuum Pumps and Systems

General Information General information A Complete Solution Gardner Denver Thomas GmbH is a global business With Welch brand products we can offer a wide unit of Gardner Denver Inc., dedicated to providing range of vacuum pump technologies to provide the value-added Laboratory and Life Science products. specific requirements for your application. Selec- We proudly offer environmentally responsible Welch ting the correct technology and a suitable pump size vacuum products for use by the scientific communi- (flow rate) ensures cost effectiveness and minimal ty and for innovative vacuum system integration in maintenance. light industrial applications. We can provide a solution tailored to your needs, Welch products are manufactured in Ilmenau, Ger- with the combination of a pump, connection kit and many – the heart of a region renowned for techni- other accessories. Our connection kits have been cal innovation - and at our Niles site, just outside specially designed to include all required parts to of Chicago. We bring a passion for precision to the connect your pump to your application. manufacture of every Welch pump, system, and We stock a wide range of KF, ISO-K and CF flange component. With the latest in CAD design, CNC components including clamps, centring rings, adap- tooling stations, and advanced LEAN manufacturing ter flanges and flexible steel tubes. We can also sup- practices, Welch stands at the forefront of progressi- ply a range of vacuum valves with manual, electronic ve vacuum design and high quality vacuum product and pneumatic operation. manufacturing. Sales and Technical Support We look forward to working with you to make vacu- um a utility perfectly matched to your need. For lo- cal sales and technical, please contact our sales and support team at the appropriate global location on the back cover. Service Welch Service: comprehensive and customer-orien- ted We have service and support centers, as well as qua- lified sales, service and support agents worldwide to ensure the best possible customer service expe- rience. When you need after-sales support, service or repair please visit www.ilmvac.com for an appro- priate contact in your area. See page 43 for further details on service, repair and warranty returns. 2 | www.welchvacuum.com

Table of Contents Table of Contents 1 4 Application Overview 4 Laboratory Vacuum Systems (LVS) 27 • Selection chart for common lab applications • Model options • Rotary Evaporation • Highlight LVS 105 T - 10 ef • Filtration / SPE • Overview of Systems • Aspiration • Technical Data • Freeze Drying • Accessories & Configurations • Schlenkline / Highlight ChemStar Dry • Vacuum oven 5 • Glove Box • Gel Dryer Oil-Sealed Rotary Vane Pumps 33 • Desiccation • Vacuum Network • Fully accessorized Packages • Configurations netvac • Connection Kits • Chemvac 2 • RVP-Trolley • Technical Data OEM Products 17 • Intake Pressure / Pumping Speed - Diagrams • Accessories • Oil 3 6 Dry, oilfree Diaphragm Pumps 18 Additional Information 42 • Highlight NEW MPC 302 Z • Common Solvents • Technical Data • Repair/Warranty guideline • Index • C hemical Duty Diaphragm Pumps • Standard Duty Diaphragm Pumps • Alphabetical • Intake Pressure / Pumping Speed - Diagrams • by CAT.No. • Accessories • Worldwide Sales & Service Offices • Connection Kits www.welchvacuum.com I 3

1 Application Overview Selection chart for common lab applications Application Overview of system Flow rate/X Vacuum Model General vacuum work MPC 301 Z Dry running pump, compact 38 l/min MPC 090 E 412722 Vacuum/pressure filtration and portable 8 mbar WOB-L 2522 412021 Glass filtration assemblies 2522C-02 SPE Filtration pump with dial 15 l/min Degassing, gauge, regulator and sepa- 100 mbar 414722 Desiccation rator 18 l/min 114184 Rotary Evaporation 133 mbar Non-Volatiles Dry piston pump 412743 Boiling point 40 °C with vacuum/pressure 412543 Samples 0-5 litres gauge, regulator, silencer 322003 Rotary Evaporation 109030 Non-Volatiles and trap 2070C-02 Boiling point 40 °C 112037, Sample 0-1 litres Economic PTFE dry pump 43 l/min MPC 302 Z 112037-04 Vacuum oven with vacuum regulation < 5 mbar LVS 105 T - 10 ef 101240 Drying Degassing Vacuum system with 600053 20 l/min 600074 Vacuum Concentrator ecoflex speed control and 2 mbar built-in Freeze dryer Lyophilizing solvent library Vacuum manifold For aqueous, acidic or basic 75 l/min MPC 601 T Schlenkline samples 2 mbar MPC 201 T P 6 Z Aspiration Minimum maintenance 36 l/min Chemvac P 6 Z - 101 2 mbar ChemStar Dry SMuoblelicmualatiroDnistillation/ With cold trap 77 l/min Combination pump system 2x10-3 mbar Biovac 106 + Handvac, Biovac 106 4l Vacuum controller Completely mounted with PP-Bottle oil mist separator and sol- 97 l/min Vacuum gauge 2x10-3 mbar vent trap 4 I www.welchvacuum.com Compact, oil free vacuum 150 l/min 7x10-2 mbar pump No trapping required 15 l/min 100 mbar Aspiration and filtration system with autoclavable container and handheld pipettor set For high vacuum and UHV 50 l/s applications 2x10-7 mbar CDK 180 Measuring range 1050 - 1 mbar Multi range vacuum gauge Measuring range VCB 521 with chemical resistant 1050 - 10-3 mbar PIZA 111 cr-gold sensor

Rotary Evaporation Description ROdist professional package with LVS 105 T - 10 ef | 112033 Rotary evaporators are widely used in chemical la- boratories as a way of evaporating solvents from a Recommended Products sample. A rotary evaporator needs to be partnered with a source of vacuum, with the vapour pressure Welch produce a wide range of vacuum pumps and of the solvent and the water bath temperature de- vacuum pump systems for use with rotary evapo- termining the vacuum level required. rators. With ultimate vacuum levels from 75 mbar A range of flask sizes can be used with a rotary eva- to 1 mbar, flow rates up to 138 l/min and a variety porator and the size (flow rate) of the vacuum pump of vacuum regulation options there‘s a pump for all should be chosen based on the flask volume being applications. used. Pumps can be regulated for better control. Regula- tion is available as manual and digital controller op- Application note tions. Some products come with vacuum regulators as standard. Ensure the correct vacuum level and flow rate for - MPC chemical duty diaphragm pumps for an eco- your pump based on the solvents being and flask size nomical option. Available in a wide range of sizes being used. Use our model selector for guidance. and accessories available for vacuum regulation Use a vacuum regulator to stop your sample from - LVS systems, built on the MPC chemical duty dia- foaming and bumping. phragm pump but with added glassware and options for built in regulation - manual or digital controller. Model Selector I Rotary Evaporators - 8890 Gem gear pump system. Designed for use with very high boiling point solvents. Includes vacu- um regulator and oil mist eliminator as part part of the package. Boiling Point, 80°C 110°C 160°C 195°C Atmospheric Pressure Example Solvents Methylene chloride Trichloroethylene 1,1,2,2,-Tetrachloroethane DMSO Acetone n-Propyl alcohol DMF Polymers Chloroform Heptane Pentachloroethane Ethanol Water Toluene Acetic Acid RotoVap Flask Volume Pump System Pump System Pump Models System Models Pump System Models Models Models Models Models Models 1L MPC 101 Z LVS 101 Z MPC 105 T, LVS 105 T-10 ef 2L MPC 105 T iQ-P LVS 101 Z MPC 201 T LVS 210 T 1400 8890C-70 10 L MPC 110 E LVS 301 Z LVS 210 T ef 1402 1402 20 L MPC 301 Z, LVS 301 Z, MPC 601 T LVS 610 T MPC 302 Z LVS 310 Z LVS 610 T ef www.welchvacuum.com I 5

1 Application Overview Rotary Evaporation LVS 105 T - 10 ef | 114184 HBP 101 | 112036 MPC 095 Z | 412422-10, LVS 105 T - 10 ef MPC 105 T | 412443-10 The LVS 105 T - 10 ef is the perfect partner for your MPC 095 Z rotary evaporator. It has been optimised for rotary evaporator application with an ultimate vacuum of 2 MPC 095 Z rotary evaporator package is an econo- mbar and peak flow of 20 l/min, allowing non-vola- mical option to partner with your rotary evaporator. tiles such as DMF to be evaporated at 30⁰C. It com- The package includes the MPC 095 Z vacuum pump, bines a powerful built in chemical duty diaphragm DBR-P vacuum regulator with dial gauge and vacu- vacuum pump with Ecoflex control principals. Hea- um hose to connect the pump to your rotary eva- ting of the pump heads allows a consistent clean porator. vacuum without gas ballasting. The Ecoflex control Built from chemical duty components and with an continuously adjusts the pumping speed to match ultimate vacuum of 5 mbar the MPC 095 Z is suita- the vapour load of the process and allows the pump ble for evaporating most common solvents. The ad- to exhibit single point control which reduces bum- dition of a vacuum regulator allows the vacuum level ping and foaming whilst achieving increased evapo- to be manually adjusted to control the evaporation ration rates. rate and reduce bumping and foaming. The built in The built in digital vacuum controller allows easy ad- vacuum gauge allows the user to monitor the vacu- justment of the desired vacuum level as well as the um level of the evaporation process. option to select common solvents from the built in solvent library. An inlet trap protects the pump from ingesting li- quids and particles and an exhaust vapour conden- ser for optimal solvent recovery. MPC 105 T HBP 101 MPC 105 T rotary evaporator package is designed Hold Back Pumps create a fully-automatic distillati- to partner with your rotary evaporator when using on process without attention to fraction quantities, non-volatile solvents. The package includes the manual adjustment, or continuous regulation. The MPC 105 T vacuum pump, DBR-P vacuum regula- resultant distillation is considerably better and more tor with dial gauge and vacuum hose to connect the economically sound than using a diaphragm pump pump to your rotary evaporator. Built from chemical system with a solenoid valve. Based on the rugged duty components and with an ultimate vacuum of 2 chemical resistant Welch MPC 301 Z, the Hold Back mbar the MPC 105 T is suitable for evaporating high Pump utilises solvent flow to automatically regulate boiling point solvents, such as DMF. the diaphragm pump vacuum level. This means that The addition of a vacuum regulator allows the va- the Hold Back Pump can be used to distil a mixture cuum level to be manually adjusted to control the of solvents without knowledge of its composition. evaporation rate and reduce bumping and foaming. The built in vacuum gauge allows the user to moni- tor the vacuum level of the evaporation process. 6 I www.welchvacuum.com

Filtration / SPE MPC 090 E | 412021 + Filtration Flask Description Recommended Products Vacuum and pressure filtration is widely used for Diaphragm or WOB-L piston pumps are generally sample preparation in chemistry, life science, envi- used for filtration applications as excessive vacuum ronmental analysis and pharmaceutical QC. Filtrati- (e. g. from a rotary vane pump) causes boiling of the on rates are greatly enhanced by creating a differen- liquid being filtered, which is undesirable. For most tial pressure across the filter unit by applying either filtration applications a modest vacuum of 75 to 150 vacuum or pressure. The ultimate differential pressu- mbar absolute, or a positive pressure of 2 to 6 bar re requirements are generally low. When filtering at is required, with free air displacement of 10 to 60 l/ 100 mbar, 90% of atmospheric pressure is available min depending on the filter size, leak rate, condition to assist the filtration. Improving the vacuum level to of the filter cake and whether a filtration manifold 50 mbar (95% vacuum) has little appreciable effect is being used to operate multiple filters simultane- on the differential pressure. ously. For filtration of aqueous solutions a WOB-L Solid phase extraction (SPE) is a sample preparation piston pump or standard duty diaphragm pump can technique which is growing in popularity. SPE gives be used. For filtration of acidic and basic solutions better yields than traditional liquid to liquid methods or organic solvents use a chemical duty MPC dia- and the wide range of available stationary phase phragm pump. For SPE the requirement is similar to forms allow for rapid processing and automation. vacuum filtration, with a chemical duty diaphragm pump necessary. Pumps with regulator valves can be used when the filtration rate needs to be con- trolled or to stop evaoration of particularly volatile liquids. Model Selector I Filtration Filtration Solvent / Media Chemical Examples Vacuum Regulation Number of Filters Model Aqueous Vapors Yes 1-2 WOB-L 2522 Suspended solids samples Yes 1-4 WOB-L 2534 Mild Chemical Vapors Food slurry analysis Yes 1-6 WOB-L 2546 Yes WOB-L 2567 Weak acid /base solutions Yes 6 funnel manifold MPC 090 E 1 MPC 090 E with Field environmental Samples Yes 1 auto adapter 2019 C-20 Low-volume Organic Vapors Alcohol Solutions No 1 MPC 090 E Strong Chemical Vapors Solid Phase Extractions Yes 1-2 MPC 301 E Chlorinated solvents Yes 1-6 MPC 601 E Strong acid /base solutions Yes 6 funnel manifold MPC 602 E Ketones www.welchvacuum.com I 7

1 Application Overview Aspiration handvac | 112580 Description Recommended Products Aspirators are used for the aspiration and disposal The Welch range includes aspiration stations with of liquids in biochemistry, microbiology and cell cul- standard duty pumps for aqueous solutions inclu- ture applications. The pump creates a vacuum in ding buffers and with chemical duty pumps for aci- the collection receiver which allows liquids to be su- dic, basic and organic solutions. All models come cked into it due to the pressure differential. The li- with autoclavable collection receiver, automatic flow quid is collected in the receiver and can be disposed stop and in-line hydrophobic filter. of when full. Application note • biovac 106 for precise aspiration of chemical, bio- logical and medical liquids. Includes HandVac pi- The most common reason for vacuum pump failure pettor as standard. Available with 2 litre glass or in aspiration applications is the ingestion of liquid 4 litre PP collection receiver. into the pump mechanism. Welch Aspiration Sta- tions integrate features that protect your pump and • 2511 for economical aspiration of aqueous liquids. your application. Routinely empty the collection re- Compact and portable with a 1.2 litre PP collec- ceiver to ensure continuous aspiration. tion receiver. • 2515 for high flow aqueous applications such as cell culture aspiration or use of multiple pipettors. Compact and portable with a 1.2 litre PP collec- tion receiver. • fluivac 105 for aspirating large volumes of chemi- cal, biological and medical liquids. Includes a 5 litre glass collection receiver. Mounted on a trol- ley for portability. biovac 106 | 112037 8 I www.welchvacuum.com

Freeze Drying Description Recommended Products Freeze drying, or lyophilisation, is the process of For freeze drying (lyophilisation) applications a high freezing a material and then sublimating any frozen vacuum levels is required, typically between 10-1 and liquid from a solid directly to a gas. Freeze drying is 10-3 mbar. There are different pump types can be commonly used as a method of preservation in food employed; oil-sealed rotary vane pumps, Chemvac and pharmaceutical industries. It allows products to combination pumps, dry scroll pumps and specialist be easily stored and transported without having to pump systems. be constantly refrigerated. Application Note • Rotary vane pump for standard freeze drying applica- tions. Ensure that your vacuum pump is sized correctly for your freeze dryer. If the flow rate of the pump is too • Chemvac combination pumps for freeze drying with high then the vapour is pulled through the conden- high organic vapour or acidic vapour loads (e.g. TFA). ser too quickly which reduces the condensing effici- A chemical duty diaphragm pump is used to degas the ency. pump oil and keep the pump clean. Clean the freeze dryer’s condenser after each run to prevent sublimation of frozen chemicals into the va- • Scrollvac scroll pumps for an oil-free solution when va- cuum pump. cuum to 10-1 mbar is required. • ChemStar Dry for oil free chemical resistant solution with self cleaning programme. Peak flow rate in the range of 0.1 - 10 mbar. Model Selector I Pump Selection - Application Chart Application P4Z P6Z/ P8Z P 12 Z / S 10 S 15 ChemStar X P 6 Z-101 P 12 Z-301 Dry Freeze dryer up to 2 kg X Ice holding capacity up to 4.5 kg up to 6 kg X X up to 8 kg XX X up to 12 kg X up to 24 kg www.welchvacuum.com I 9

1 Application Overview Schlenkline / Highlight ChemStar Dry Description Recommended Products Schlenk lines, also know as vacuum manifolds, are a The traditional pump for Schlenk line applica- widely used piece of apparatus in many chemistry tions is an oil sealed rotary vane pump due to laboratories. They are commonly used for the final their deep vacuum performance. A cold trap drying stage of samples from rotary evaporators. should be used to trap solvents before they enter The vacuum pump is used to remove any solvents or the pump. A Chemvac combination pump can be acids which are remaining after the distillation pro- used to achieve longer oil service intervals. New cess. ChemStar Dry is a dry chemical resistant alternative. Application note • Rotary vane pump. Packages available with all required components. It is generally not necessary to have a pump with a high flow rate for Schlenk Line applications. The • Chemvac corrosion optimised combination system for flow rate of the application is restricted by the size extended oil service intervals. Enjoy the same benefits of the manifold and stopcock. Using a pump which as a rotary vane pump, but with longer life due to a is too large can cause vapours to flow through the chemical duty diaphragm pump distilling the pump oil. cold trap too quickly and not have time to condense. This contaminates the pump and will shorten pump • ChemStar Dry for oil free chemical resistant solution life. with self cleaning programme and no cold trap requi- red. Highlight - ChemStar Dry The revolutionary new Welch ChemStar Dry vacuum system integrates a proprietary vacuum blower with patented PTFE diaphragm technology. ChemStar Dry pulls a deep vacuum without the risk of oil va- pour contamination. The proprietary protective coatings mean that no trapping is required saving the cost, space and maintenance of a cold trap. A self cleaning programme purges the pump system on shut down to remove residues and therefore ex- tend the life of the pump. ChemStar Dry | 2070C-02 10 I www.welchvacuum.com

Vacuum oven Description Recommended Products Vacuum ovens are used for drying sensitive subs- For most vacuum oven applications a dry pump can tances, which may be damaged by excess heat, and be used and this could be either a WOB-L piston where extremely low residual moisture levels are de- pump for a diaphragm pump. When low volatility manded. Depending on the solvents used and the solvents are being removed at low temperatures temperature limitations of the samples and chamber, then an oil-sealed rotary vane pump is required. a medium to high ultimate vacuum is generally re- quired from the pump. The potentially large quan- • WOB-L piston pumps for fast drying of aqueous sam- tities of vapour generated from the chamber also ples. These oil free two stage pumps have a high flow mean that the pump should handle vapours well; rate, can create a deep vacuum below 10 mbar and these may be aqueous, basic or acidic. Piston and come with an inlet trap, vacuum regulator and dial va- diaphragm pumps are most suitable, with PTFE con- cuum gauge as standard. structed diaphragm pumps being employed where chemical resistance is most important. High flow ra- • MPC diaphragm pumps for chemical duty drying ap- tes may also be needed where vapour volumes are plications. With PTFE components these pumps are large. ideal when organic solvents are being removed from samples. • LVS diaphragm pump systems for extra protection for your MPC pump and air quality with inlet separator and exhaust condenser. If vacuum level control is required then and LVS system is ideal. • Rotary vane pumps for fast drying of low volatility sol- vents. One stage or two stage pumps depending on vacuum level requirement. Use AKS inlet separator to protect pump from ingestion of liquids or particles. Model Selector l Vacuum Ovens Oil-Free Vacuum Oil-Seal Deep Vacuum 2 to 10 mbar 0.1 mbar to 10-3 mbar Oven Aqueous Chemical Single stage Two stage Volume Vapours Vapours direct drive direct drive Up to 20 litres 2561C-50 MPC 301 Z P4E P4Z Up to 50 litres 2561C-50 MPC 302 Z P4E P4Z Up to 120 litres 2581C-50 MPC 602 T P6E P6Z Up to 250 litres 2581C-50 S 15 P8E P8Z www.welchvacuum.com I 11

1 Application Overview Glove Box Description Recommended Products Glove boxes are used to house a controlled environ- Standard glove boxes and transfer chambers are ment either for isolation of sensitive substances or not normally evacuated much below 20 mbar due to protect users from hazardous substances. They to plastic material limitations. Both acrylic and po- have built in gloves to allow users to manipulate the lycarbonate which are used in standard glove boxes substances inside of the glove box. A vacuum pump are not suited for deep vacuum. High end glove bo- is used to remove ambient air from the glove box xes capable of deeper vacuum normally are const- and then it can be backfilled with an inert gas, such ructed of stainless steel & heavy glass plates. These as Argon. This process can be repeated to achieve a can generally be evacuated below 1 mbar. lower oxygen concentration. Transfer chambers also need to be evacuated to ensure that the external at- • 2 stage oil free WOB-L piston pumps for vacuum down mosphere does not enter the glove box. to 7 mbar. Suitable for aqueous vapours only. • Scroll pumps for when a deeper oil free vacuum is re- quired. • 2 stage rotary vane pumps for when a deep vacuum is required. With a high pumping speed these pumps are suitable for larger glove boxes also. An anti suck back valve ensures that there is no back flow of oil into the glove box. Gel Dryer Recommended Products There are two options of vacuum pump technology when it comes to gel drying; LVS diaphragm pump system or Gelmaster™ system. Description • LVS 300 Z with a powerful chemical duty MPC 301 Z base diaphragm pump and inlet and exhaust separa- Vacuum drying of gels is a common preparation tors to trap liquids and particles. technique for gel electrophoresis applications. The gel is heated on a gel dryer and vacuum is applied • The revolutionary Gelmaster™ gel dryer vacuum sys- to improve the drying. A medium vacuum level is tems unique design uses a patented room temperature required for gel drying. vapour trap with a built-in dry vacuum pump. Con- densate is collected in liquid form and doesn‘t have an effect on performance, so the tenth drying run is as fast as the first. When the collector reaches capacity, simply drain the contents and begin again. 12 I www.welchvacuum.com

Desiccation Description MP 065 E | 411011 Vacuum desiccators are used frequently in labora- Recommended Products tories for the removal of moisture in a sample, main- tenance of a dust and moisture-free environment, A WOB-L piston pump or diaphragm pump is the vacuum testing, defoaming and storing samples un- best option for use with a vacuum desiccator. Both der various atmospheres. Some substances oxidise technologies are oil free so there is no chance of any when exposed to air. To reduce the reaction rate the oil contamination. Generally a single stage pump is substances can be kept under vacuum in a desicca- required for process applications and a two stage tor. pump is required for storage applications. The free air displacement of the pump should be matched to the size of the desiccator to ensure a satisfactory pump down time. • Use WOB-L piston pumps for standard duty aqueous applications, with a high pumping speed for quick eva- cuation of your desiccator. These pumps come with a vacuum regulator and dial vacuum gauge as standard for controlled evacuation and vacuum level monitoring. • Use chemical duty MPC diaphragm pumps when sol- vents are being used. These rugged diaphragm pumps use PTFE and other chemical duty materials for protec- tion against damage from solvents. Use the optional DRB regulator with dial gauge if vacuum regulation is required. Model selector | Dessication Desiccator Type Application Pumping speed Model CAT. No. Small benchtop Process Aqueous vapours Small cabinet (<25 litres) Storage & vacuum MP 065 E 411011 Chemical vapours Large cabinet (>25 litres) Process Small benchtop Storage 0,7 m³/h MP 055 Z 411422 Small cabinet (<25 litres) Process 100mbar Large cabinet (>25 litres) Storage 0,5 m³/h 2534C-02 2534C-02 Process <5 mbar Storage 2561C-50 2561C-50 Process 1,7 m³/h Storage 93 mbar 2561C-50 2561C-50 Process 3,0 m³/h 6,7 mbar 2561C-50 2561C-50 Storage 3,0 m³/h 6,7 mbar MPC 090 E 412021 3,0 m³/h 6,7 mbar MPC 095 Z 412422-02 1,0 m³/h MPC 301 E 412711 100 mbar 0,9 m³/h MPC 302 Z 414722 5 mbar MPC 601 E 412721 2,3 m³/h MPC 302 Z 414722 <75 mbar 2,6 m³/h MPC 302 Z 414722 <5 mbar 3,8 m³/h <75 mbar 2,6 m³/h <5 mbar 2,6 m³/h <5 mbar www.welchvacuum.com I 13

1 Application Overview Vacuum Network Description We provide a multi-user vacuum network that is: • Precisely controlled at your point of application Make precision vacuum readily available for all • Cabinet concealed with accessible controls users and applications in your lab – all from a single • Energy efficient and environmentally responsible Netvac installation. Using Welch vacuum pumps, • Oil-free, chemical resistant and low maintenance controllers, systems and components we can cus- tom design a robust laboratory vacuum network to provide the right performance to each of your applications. 5 Steps to your Personal Netvac 1. How many Netvac ports are required? 2. What ultimate pressure is required? (2 mbar or 8 mbar) 3. Will the Netvac ports be mounted on the bench or fume hood? 4. Will your Netvac ports be surface-mounted (R04) or integrated (R01) into lab furniture? • Surface mounted - • For integration into la- common solution boratory furniture. Va- for installation for cuum hose is hidden and existing laborato- out of the way. ry furniture or on walls. front back 5. Do you need manual regulated or controller regulated ports? • Manual Regulated • Controller Regulated Manual on/off, vacuum With digital vacuum regulator and dial gauge. + controller VCZ 521. Advantages • Operate up to 30 vacuum ports with a single system • Tailored system to your requirements • Ideal ecomonical solution for new lab contruction or • Chemical duty components for pumping solvent and lab renovations acidic vapours • Single pump system serves multiple vacuum applica- • Oil free system - no oil changes required or waste oil to tions dispose of • Modular construction enables incremental port and component addition 14 I www.welchvacuum.com

Vacuum Network Description Recommended Products Netvac area vacuum systems provide vacuum on Using Welch pumps, controllers, systems and com- demand for all the users and applications in your lab ponents, we can custom design your laboratory - all from a single system. vacuum utility to provide the right performance to each of your applications. Univac MPKC Systems The Univac systems are available with eith 4 or 6 Univac - MPKC 2403 T | 112223 MPC diaphragm pumps mounted on a trolley with a microprocessor control system. With ultimate vacu- um options of 75 mbar, 8 mbar and 2 mbar and with peak flow rates of up to 50 m3/h the Univac systems are designed to supply vacuum to your whole lab. The built in digital controller allows the vacuum le- vel to be controlled and only runs the quantity of pumps necessary to achieve the requirement of the users, saving energy as well as wear on the pumps. When the demand is not 100& the controller cycles the pump(s) being used to ensure even wear. LVS 210 T ef The LVS 210 T ef is an excellent solution for conti- LVS 210 T ef | 115234 nuous, chemical resistant and oil-free proceeding with corrosive and aggressive gases and vapours. Besides the intelligent ecoflex control system, the connected chemical duty diaphragm pump is very quiet in operation and can be reached easily for cleaning or maintenance purposes. With an ultimate vacuum of 2 mbar and a peak flow of 36 l/min the LVS 210 T ef has been optimised for applications in chemical, biological and pharmaceu- tical laboratories and is suitable for use in multi user network (Netvac) systems. The Ecoflex control con- tinuously adjusts the pumping speed to match the vapour load of the process. An inlet trap protects the pump from ingesting liquids and particles and an exhaust vapour condenser for optimal solvent re- covery. LVS 610 T ef The LVS 610 T ef is an excellent oil-free, chemical LVS 610 T ef | 115254 resistant solution for multi user network (Netvac) systems. With an ultimate vacuum of 2 mbar and a peak flow of 81 l/min the LVS 610 T ef has been op- timised for applications in chemical, biological and pharmaceutical laboratories and can pump corrosi- ve and aggressive gases and vapours. The high flow rate and deep vacuum allow it to supply vacuum to approximately 10 individual ports. It is designed for continuous duty and comes with the ecoflex control system which continuously ad- justs the pumping speed to match the vapour load of the process and allows the pump to operated un- attended. An inlet trap protects the pump from in- gesting liquids and particles and an exhaust vapour condenser for optimal solvent recovery. www.welchvacuum.com I 15

1 Application Overview Configurations netvac Description Selecting separate pump and controller options creates flexibility in your Netvac installation. Choose Netvac installations can be configured in a versatile from a wide range of PTFE vacuum pumps and add a manner either as a fully integrated (LVS) system or a precision controller - either table top or flush moun- separate vacuum pump and digital controller. Ener- ted. Selecting an integrated Laboratory Vacuum gy saving control options can be used with both System (LVS) provides additional standard features, configurations to make your Netvac system good such as integrated inlet trap before the pump and a for both the environment and your budget: liquid-cooled exhaust condenser after the pump to • Economic (en) control only runs the pump when there capture any residual vapours prior to discharge into the atmosphere. is a user demand • Ecoflex (ef) control varies the speed of the pump to maintain the desired vacuum Model Selector I Vacuum Network Netvac Pump Selection Chart This simple guide indicates the number of vacuum ports generally served by each available vacuum source. Contact your local representative to assess your own requirements. Vacuum Pump Model ultimate pressure 5 ports 10 ports 20 ports 30 ports LVS 301 Z / 310 Z / en / ef 8mbar x x LVS 601 T / 610 T / en / ef 2mbar x x Univac - MPKC 2403 T 2mbar x x x x Univac - MPKC 3603 Z 8mbar Customized Solution 2 or 8 mbar Netvac Port and Controller Selection Chart - Netvac Ports with Integral Check Valves This selection chart indicates the most common Netvac ports. If you do not see what you need, please con- tact your Welch representative. Bench-Top Controller Regulated Fume Hood Manual Regulated On/Off Manual Regulated Flush Mount (R01) CAT. No. 700532 700535 700538 700532 700541 700531 No Vac. Reg. Man. Vac. Man. Vac. Reg. Use With Use With Use with 700519 or 700546 Regulated 600053 600052-09 w/Dial Surface Mount (R04) CAT. No. 700532-03 700535-03 700538-03 600053 600052-05 700519 700546 No Vac. Reg. Man. Vac. Man. Vac. Reg. Table Top Cont- Flush Mnt Man. Vac. Man. Vac. Regulated Controller Regulated Reg. On/Off W/Dial roller 16 I www.welchvacuum.com

2 OEM Products OEM Products Expertise Individual Consultation At Welch we have the expertise to offer a custom Contact your local sales and technical support team solution for your OEM vacuum pump requirements. at the appropriate global location (see back cover Whether your requirement are similar to one of our for details) to discuss your specific requirements. standard catalogue pumps or if you require a com- We will discuss your specification requirements and pletely bespoke package we have a solution to offer. the different pump options which may be suitable. We have a range of pumps specifically designed to We have extensive application knowledge and expe- be built in to OEM equipment. These pumps come rience of working with OEMs. with 24V BLDC motors and mouting brackets for in- stallation inside equipment. They are available in 1, 2 MPC 105 T | 412443-04 and 3 stage configurations, offering a vacuum level suitable for your specification. We can offer modifications of standard pumps, such as different motor voltage, colour, inlet and exhaust connectors, removal of features (e.g. carrying hand- le) and addition of accessories (e.g. vacuum regula- tor). We can use our wide range of KF, ISO-F and CF vacuum fittings and valves to either supply a pump with additional fittings already connected ready for drop in assembly on your production line or as a pa- cakge of additional parts to be supplied along with the pump. We can fabricate custom flange components, spe- cial length flexible steel vacuum hoses and bespoke vacuum receipients in our production facilities. Our design, product development and production facilities have management systems certified accor- ding to ISO9001. MP 030 Z | 420301-12 www.welchvacuum.com I 17

3 Diaphragm Pumps Dry, oilfree Diaphragm Pumps Advantages • analytically pure, oil free vacuum • user friendly • light weight, rugged design • designed for permanent operation • maintenance-free drive system and proven long diaphragm life • minimal operation vibration • wide vacuum and flow range to match applica- tion • superior chemical resistance (MPC models) MPC 601 T | 412743 Scope of Delivery Range of Applications • ON/OFF switch and internal protective thermal • rotary evaporators switch for the motor, mains cable and plug • vacuum ovens • degassing / desiccation • carry handle • vacuum distillation • vibration isolating feet • vacuum filtration • MP models come with and exhaust silencer • solid phase extraction (SPE) • MPC models come with a gas ballast valve • gas sampling • vacuum drying • vacuum holding • pick and place • backing turbomolecular pumps Description standing diaphragm life and market leading cost of ownership. Use MP models for standard duty appli- Welch diaphragm pumps have been developed spe- cations and MPC models for chemical duty applica- cifically to meet the requirement for oil-free vacuum tions. The MPC models use PTFE and other fluorina- generation. Their low weight and excellent ergono- ted plastics for the wetted parts to allow aggressive mics, make Welch diaphragm pumps the first choice solvent and acid vapours to be pumped. For extra for most laboratory applications. With ultimate va- harsh chemical vapours use X2 versions. Ecoflex cuum from 75 to 1 mbar and peak flow rates up to versions with variable speed motors are also availa- 138 l/min there is a specific model configuration to ble. suit almost all applications. Our proven diaphragm technology offers a double benefit to the user – out- 18 | www.welchvacuum.com

Highlight NEW MPC 302 Z Advantages MPC 302 Z | 414722 • analytically pure, oil free vacuum • user friendly • light weight, rugged design • designed for permanent operation • maintenance-free drive system and proven long dia- phragm life • minimal operation vibration • significantly improve flow and vacuum performance in the application critical range • superior chemical resistance • stabilised process flow • enhanced repeatability Scope of Delivery • ON/OFF switch and internal protective thermal switch for the motor, mains cable and plug • carry handle • vibration isolating feet • gas ballast valve • KF 16 inlet flange / 8mm hose nozzle NEW MPC 302 Z to similar products of the previous generation. Be- sides the pumping speed, the ultimate vacuum is No matter if for research and development appli- improved as well to 5 mbar. These significant impro- cations or in the analysis field, the latest generati- vements directly influence the process flow and the on of Welch’s diaphragm pumps are suitable for repeatability. A more stable applied vacuum gives a a wide range of laboratory applications. The new more repeatable application and achieves more reli- MPC 302 Z uses a patented pump head design to able results. The effectiveness and quality of chemi- provide significantly improved performance, par- cal applications, especially distillation processes are ticularly in the application critical range. Opti- improved. mised construction of the pump heads allows the MPC 302 Z to reach a 17% higher pumping speed in the application critical vacuum range compared Accessories for MPC 302 Z CAT.No. Accessoires 600053 Digital Vacuum Control Box VCB 521 cv, 1100 - 1 mbar, 90-260V, 50/60Hz 700458 with Schuko, UK and US plug leads 828310-4 Vacuum Regulator with Dial Gauge for MP/MPC 301 Z, 601 E, 601 T, 901 Z, 1201 E Vacuum Hose, Rubber red, 18/8x5, meter www.welchvacuum.com I 19

3 Diaphragm Pumps Technical Data - Chemical Duty Diaphragm Pumps Premium selection Chemical Duty Diaphragm Pumps Parameter MPC 090 E MPC 110 E MPC 095 Z MPC 155 Z MPC 105 T MPC 105 T iQ Number of heads/stages Free Air Displacement, m³/h 1/1 2/1 2/2 4/2 4/3 4/3 Free Air Displacement, l/min 1,0 Ultimate pressure, mbar 16,7 1,0 0,9 1,4 1,2 1,2 100 Intake connection Hose nozzle 16,7 15 23 20 20 DN 6 Exhaust connection Hose nozzle 50 5 5 <2 <2 Sound level DN 6 Dimensions (B/T/H), mm <45 Hose nozzle Hose nozzle Hose nozzle Hose nozzle Hose nozzle Weight, kg 144/198(130) DN 8 DN 8 DN 8 DN 8 DN 8 Ordering Information /244 90...260VAC 2,7 Hose nozzle Hose nozzle Hose nozzle Hose nozzle Hose nozzle DN 8 DN 8 DN 8 DN 8 DN 8 412021 <45 <45 <45 <45 <45 235/140 235/140 235/145 235/145 235/145 /277 /277 /327 /327 /327 6,15 6,15 6,5 6,5 6,5 412421-02 412422-02 412642 412443-02 412443-17 One-Stage Direct-Driven Diaphragm Pumps, Ultimate pressure <75 mbar Parameter MPR 060 E-EC MPC 201 E MPC 301 E MPC 302 E MPC 601 E MPC 602 E MPC 1201 E MPC 2401 E 2/1 1/1 1/1 2/1 8/1 Number of heads/stages 2/1 1,8/2 2/1 4/1 2,3/2,5 2,9/3,5 3,8/4,2 4,2/5,0 15,5/17,0 Free Air Displacement, m³/h 0,6 30/33 38/41 48/58 63/70 70/83 8,3/9,1 258/283 < 75 < 75 < 40 < 30 Free Air Displacement, l/min 10 < 75 DN 16 KF 138/151 < 75 Hose nozzle Hose nozzle Hose nozzle with optional Ultimate pressure, mbar <60 DN 8 DN 8 DN 8 DN 16 KF with Hose nozzle < 75 DN 16 KF optional Hose DN 8 Intake connection Hose nozzle nozzle DN 8 DN 16 KF DN 6/8 Hose nozzle with optional DN 8 Hose nozzle <44 DN 8 233/260/171 Exhaust connection Hose nozzle Hose nozzle Hose sleeve A 10 – 8 Hose sleeve A 10 – 8 Hose nozzle Hose nozzle DN 16 KF DN 6/8 DN 8 or optional (enclosed) or optional (enclosed) DN 8 11,2 DN 8 Sound level Exhaust silencer A 10 Exhaust silencer A 10 Dimensions (B/T/H), mm 42 <44 - Weight, kg 115/165/145 195/225/147 <45 <45 <44 414721 <44 <44 Ordering Information 156/260/253 156/260/253 230/265/170 414721-01 230/380/170 540/300/240 90...260VAC 2,3 6,5 414721-02 230V 50/60Hz 8,9 8,9 11,2 18,3 32,8 115V 50/60Hz 412121 400V 50/60Hz - - - - - - - - 412521 412711 414711 412721 412741 412781 - 412521-01 412711-01 412721-01 412741-01 412781-01 - 412721-02 412741-02 412781-02 - - - 20 I www.welchvacuum.com

Technical Data - Chemical Duty Diaphragm Pumps Multi-Stage Direct-Driven Diaphragm Pumps Two-Stage Direct-Driven Diaphragm Pumps, Three-Stage Direct-Driven Diaphragm Pumps, Ultimate Pressure <8 mbar Ultimate Pressure <2 mbar Parameter MPR 030 Z-EC MPC 101 Z MPC 301 Z MPC 302 Z MPC 901 Z MPC 1801 Z MPC 201 T MPC 601 T MPC 1201 T 2/2 8/2 8/3 Number of heads/stages 2/2 1/1,1 2/2 2/2 4/2 4/3 4/3 12/13,3 2/2,2 8,3/9,1 Free Air Displacement, m³/h 0,35 16,7/18 2,3/2,5 2,6/3,1 6,8/7,5 201/221 33/36 4,5/4,9 135/151 <8 <2 Free Air Displacement, l/min 5,8 38/41 43/52 113/124 <8 75/81 <2 Hose nozzle Ultimate pressure, mbar <5 <8 <5 <8 DN 16 KF DN 8 <2 DN 16 KF Intake connection Hose nozzle DN Hose nozzle DN 16 KF with DN 16 KF with DN 16 KF with DN 16 KF Hose nozzle DN 16 KF with DN 16 KF 6/8 DN 8 optional Hose optional Hose optional Hose <44 DN 8 optional Hose <44 Exhaust connection nozzle DN 8 nozzle DN 8 nozzle DN 8 <45 nozzle DN 8 Sound level Hose nozzle DN Hose nozzle Hose nozzle Hose nozzle Hose nozzle 540/300 Hose nozzle 540/300/ Dimensions (B/T/H), mm 6/8 DN 8 /240 200/260 240 Weight, kg 38 DN 8 DN 8 DN 8 32,8 /150 DN 8 32,8 <44 <44 <44 <44 10,3 <44 115/165 230/265 233/260 230/380 230/380 /145 195/225 /170 /171 /170 /170 /147 11,2 11,2 18,3 18,3 2,3 6,5 Ordering Information 412122 - - - - - - - - - 412522 412722 414722 412742 412782 412543 412743 412783 90...260VAC - 412522-01 412722-01 414722-01 412742-01 412782-01 412543-01 412743-01 412783 230V 50/60Hz - 412722-02 414722-02 412742-02 412782-02 412743-02 412783-02 115V 50/60Hz - - 400V 50/60Hz High Chemical/Corrosion Duty Diaphragm Pumps Parameter MPC 301 E-X2 MPC 601 E-X2 MPC 1201 E-X2 MPC 2401 E-X2 MPC 301 Z-X2 MPC 901 Z-X2 MPC 1801 Z-X2 MPC 601 T-X2 MPC 1201 T-X2 Number of heads/stages 1/1 2/1 4/1 8/1 2/2 4/2 8/2 4/3 8/3 Free Air Displacement, m³/h 2,3/2,5 3,8/4,2 8,3/9,1 15,5/17,0 2,3/2,5 6,8/7,5 12/13,3 4,5/4,9 8,3/9,1 Free Air Displacement, l/min 38/41 63/70 138/151 258/283 38/41 113/124 201/221 75/81 135/151 Ultimate pressure, mbar < 75 < 75 < 75 < 75 <8 <8 <8 <2 <2 Intake connection DN 16 KF with DN 16 KF DN 16 KF with DN 16 KF with DN 16 KF DN 16 KF with DN 16 KF Hose nozzle DN 16 KF with optional Hose optional Hose optional Hose optional Hose Exhaust connection DN8 optional Hose nozzle DN 8 DN 16 KF nozzle DN 8 nozzle DN 8 DN 16 KF nozzle DN 8 DN 16 KF nozzle DN 8 Sound level Hose sleeve Hose nozzle <44 <44 Hose nozzle <44 Dimensions (B/T/H), mm A 10 – 8 or DN8 540/300 540/300 DN8 540/300 Weight, kg optional (enc- Hose nozzle Hose nozzle Hose nozzle losed) Exhaust DN8 <44 /240 DN8 DN8 /240 <44 /240 230/380 32,8 32,8 230/380 32,8 silencer A 10 /170 /170 <45 <44 18,3 <44 <44 18,3 156/260 230/265 230/265 230/380 /253 /170 /170 /170 8,9 11,2 11,2 18,3 Ordering Information 230V 50/60Hz 412711-03 412721-03 412741-03 412781-03 412722-17 412742-07 412782-03 412743-03 412783-03 www.welchvacuum.com I 21

3 Diaphragm Pumps Technical Data - Chemical Duty Diaphragm Pumps More Diaphragm Pumps ATEX Ecoflex Parameter MPC 301 Zp, ATEX MPC 601 Tp, MPC 301 Z ef MPC 601 T ef MPC 1201 T ef 4/3 8/3 Number of heads/stages Kat.2 ATEX Kat.2 2/2 4,9 8,3 Free Air Displacement, m³/h 2,6 75 138 Free Air Displacement, l/min 2/2 4/3 43 <2 <2 Ultimate pressure, mbar <8 2,3 4,5 DN 16 KF with optional DN 16 KF with optional DN 16 KF Intake connection Hose nozzle DN 8 Hose nozzle DN 8 38 75 Hose nozzle DN 8 Hose nozzle DN 8 DN 16 KF Exhaust connection <47 <47 <47 Sound level <8 <2 260/310/190 260/390/170 Dimensions (W/D/H), mm 15,5 22,6 540/262/390 Weight, kg Hose nozzle DN8 DN 16 KF 34,0 - Hose nozzle DN 8 DN 16 KF 412943 - 412943-01 412983 <44 <44 412983-03 - 240/300/260 240/425/272 - 22,9 29,7 Ordering Information - - - 90...260VAC - - 412922 230V 50/60Hz - - 412922-01 115V 50/60Hz 4000481-04 4000511-04 400V 50/60Hz - Technical Data - Standard Duty Diaphragm Pumps One-Stage Direct-Driven Diaphragm Pumps, Ultimate pressure <75 mbar Parameter MP 065 E MP 065 E + MP 105 E MP 201 E MP 301 E MP 601 E MP 1201 E MP 2401 E Inlinefilter-Kit 8/1 Number of heads/stages 2/1 2/1 2/1 1/1 2/1 4/1 Free Air Displacement, m³/h 0,7 2/1 0,9/1,0 1,8/2 2,3/2,5 3,8/4,2 8,3/9,1 15,5/17,0 Free Air Displacement, l/min 11,6 0,7 15/16,6 30/33 38/41 63/70 138/151 258/283 Ultimate pressure, mbar 100 < 75 < 75 11,6 < 60 <75 < 75 DN 16 KF with < 75 Hose nozzle DN 16 KF with optional Hose 100 Hose nozzle DN 8 Hose nozzle optional Hose nozzle DN 8 DN 16 KF DN 8 DN 8 nozzle DN 8 Intake connection Hose nozzle Hose nozzle Hose nozzle Hose nozzle DN 16 KF DN 6 DN 6 Hose nozzle DN 8 Hose nozzle Hose nozzle DN 8 DN 8 DN 8 DN 8 <44 Hose nozzle DN 6, Hose nozzle DN 6, <44 <44 540/300/240 Exhaust connection w/exhaust silencer w/exhaust silencer <45 195/225/147 <45 <44 230/380/170 (removable) (removable) 235/140/277 156/260/253 230/265/170 32,8 Sound level 6,5 18,3 Dimensions (B/T/H), mm <45 <45 6,25 8,9 11,2 Weight, kg - 144/127/196 144/127/196 - 411521 411421 411521-01 2,3 2,3 411421 - Ordering Information 411011 411011-01 - - - - - - - 411711 411721 411741 411781 90...260VAC - - 411711-01 411721-01 411741-01 411781-01 230V 50/60Hz - - 411721-02 411741-02 411781-02 115V 50/60Hz - 400V 50/60Hz 22 I www.welchvacuum.com

Technical Data - Standard Duty Diaphragm Pumps Two-Stage Direct-Driven Diaphragm Pumps, Ultimate Pressure <8 mbar Parameter MP 030 Z-EC MP 055 Z MP 101 Z MP 301 Z MP 901 Z MP 1801 Z 2/2 8/2 Number of heads/stages 2/2 2/2 2/2 4/2 Free Air Displacement, m³/h 0,35 0,5/0,55 1/1,1 12/13,3 Free Air Displacement, l/min 5,8 8/9,1 16,7/18 2,3/2,5 6,8/7,5 201/221 Ultimate pressure, mbar <5 <5 <8 38/41 113/124 <8 Intake connection Hose nozzle Hose nozzle Hose nozzle DN6/8 DN 8 DN 8 <8 <8 DN 16 KF Exhaust connection Hose nozzle Hose nozzle Hose nozzle DN 16 KF with DN 16 KF with DN 16 KF DN6/8 DN 8 DN 8 optional Hose optional Hose Sound level 38 <45 <44 nozzle DN 8 nozzle DN 8 <44 115/165 Hose nozzle Hose nozzle 540/300 Dimensions (B/T/H), mm /145 235/140 195/225 2,3 /277 /147 DN 8 DN 8 /240 Weight, kg 6,25 6,5 <44 <44 32,8 411122 230/265 230/410 Ordering Information - - /170 /170 - 90...260VAC - 411422 11,2 18,3 411782 230V 50/60Hz - 411422 411782-01 115V 50/60Hz - - - 411782-02 400V 50/60Hz - 411522 411722 411742 411522-01 411722-01 411742-01 411722-02 411742-02 - more Multi-Stage Direct-Driven Diaphragm Pumps Three-Stage Direct-Driven Diaphragm Pumps, Four-Stage Direct-Driven Diaphragm Pumps, Ultimate Pressure <2 mbar Ultimate Pressure <1 mbar Parameter MP 201 T MP 601 T MP 1201 T MP 101 V MP 301 V Number of heads/stages 4/3 4/3 8/3 4/4 4/4 Free Air Displacement, m³/h 2/2,2 Free Air Displacement, l/min 4,5/4,9 8,3/9,1 1,0 / 1,1 2,3/2,5 Ultimate pressure, mbar 33/36 75/81 135/151 16,7/18 38/41 <2 Intake connection <2 <2 <1 <1 Exhaust connection Hose nozzle DN 16 KF with optional DN 16 KF Hose nozzle DN 16 KF with optional Hose nozzle DN 8 DN 8 Hose nozzle DN 8 Sound level DN 8 Dimensions (B/T/H), mm Hose nozzle Hose nozzle DN 16 KF Hose nozzle Hose nozzle DN 8 DN 8 DN 8 DN 8 Weight, kg <44 Ordering Information <45 <44 540/300 <45 <44 90...260VAC 230V 50/60Hz 200/260 230/380 /240 200/260 230/380 115V 50/60Hz /150 /170 32,8 /150 /170 400V 50/60Hz 10,3 18,3 10,3 18,3 - - - - - 411543 411743 411783 411544 411744 411543-01 411743-01 411783-01 411544-01 411744-01 411743-02 411783-02 411744-02 - - www.welchvacuum.com I 23

3 Diaphragm Pumps Intake Pressure / Pumping Speed - Diagrams 24 I www.welchvacuum.com

Accessories Vacuum Regulators, Gauges and Glassware Vacuum regulators for mounting to the inlet of the MP/MPC pump to regulate the vacuum level by way of a bleed valve. There are different options depending on pump model and also glassware to protect pump from ingestion of liquids / particles and to condense and collect exhaust vapours. CAT. No. Accessories for 700458 Vacuum regulator with dial gauge MP/MPC 301 Z, 601 E, 601 T, 901 Z, 1201 E 700458-01 700458-02 Vacuum regulator with dial gauge and liquid trap MP/MPC 301 E 700459 700459-01 Vacuum regulator with dial gauge MP/MPC 095 Z, 110 E, MPC 105 T, MPC 155 Z 700459-02 Vacuum regulator with dial gauge MP/MPC 095 Z, 110 E, MPC 105 T, MPC 155 Z 700460 700461 Vacuum regulator with digital gauge and pressure re- MP/MPC 095 Z, 110 E, MPC 105 T, MPC 155 Z 700462 lease valve Digital vacuum gauge MPC 105 T iQ Inlet separator MP/MPC 095 Z, 110 E, MPC 105 T, MPC 155 Z Vacuum regulator with dial gauge and inlet separator MP/MPC 095 Z, 110 E, MPC 105 T, MPC 155 Exhaust condenser / solvent recovery unit MPC 095 Z, 110 E, 105 T, 155 Z 700458 700458-01, 700459 700459-01, 700460 700461 700458-02 700459-02 Vacuum Hose Vacuum hose for connection between your vacuum pump and laboratory equipment. Please indicated the required length in metres. CAT. No. Accessories Size 828310-3 Red rubber vacuum hose, 10mm ID, 5mm wall thickness 828310-4 Red rubber vacuum hose 8mm ID, 5mm wall thickness 828374 Silicone vacuum hose 6mm ID, 3mm wall thickness 828310-3, 828374 828310-4 www.welchvacuum.com I 25

3 Diaphragm Pumps Connection Kits Connection Kits Vacuum Oven Kit Advanced Vacuum Filtration and Vacuum Oven Kit Desiccation Kit • For easy connection of diaphragm pump to vacuum oven with either • For extra protection when connec- • Quick connection to vacuum filtra- DN 16 KF or DN 25 KF flange ting diaphragm pump to vacuum tion funnel / manifold or desiccator oven with either DN 16 KF or DN 25 • Vacuum oven kit includes 2.5m va- KF flange • Kit includes in-line hydrophobic cuum hose, hose connectors, hin- filter, 1.5 m silicone vacuum hose ged clamping rings and centering • Advanced vacuum oven kit inclu- (6mm ID) and 1.5m silicone vacuum rings des 2.5m vacuum hose, hose con- hose (8mm ID) nectors, hinged clamping rings, • CAT. No. 404005 centering rings and in-line particle • CAT. No. 404008 filter with spare element. • CAT. No. 404006 Vacuum Oven Kit | 404005 Advanced Vacuum Oven Kit Vacuum Filtration and Desiccation | 404006 Kit | 404008 Rotary Evaporator Kit Other Accessories Exhaust silencers • Quick and easy connection to rota- • CAT. No. 112555-04 - In-line hydro- CAT. No. for Type ry evaporators phobic filter 829901 MP 101 Z, MP 101 V, MP 201 T, • Kit includes 2m vacuum hose, coo- • CAT. No. 829923 - Y-piece hose MP 601 E, MP 601 T, MP 901 ling water hose and clamps connector 400942 Z, MP 1201 E 400596 • CAT. No. 112575 • CAT. No. 825261 - Auto adapter for MP 060 E, MP 055 Z, MP MP 065 E / MPC 090 E, 12 - 24 VDC 105 E for field use MP 301 Z, MP 301 V 400941 MP 301 E 112555-04 829923 829901 400592 Rotary Evaporator Kit 825261 | 112575 26 I www.welchvacuum.com

4 LVS Laboratory Vacuum Systems (LVS) Advantages • analytically pure, oil free vacuum • user friendly • designed for permanent operation • maintenance-free drive system and proven long dia- phragm life • wide vacuum and flow range to match application • fully chemically resistant • inlet separator to protect pump from liquid and particle ingestion • exhaust condenser for optimal solvent recovery • modular design to tailor the system to your application needs LVS 210 T ef | 115234 Scope of Delivery Range of Applications • Chemical duty diaphragm pump mounted on chassis • rotary evaporators • ON/OFF switch and internal protective thermal switch • vacuum ovens • multi-user networks (Netvac) for the motor, mains cable and plug • solvent concentration • vibration isolating feet • inlet separator • exhaust condenser (except for LVS 300 Z) • gas ballast valve (except for LVS 105 T - 10 ef) • 8mm inlet / exhaust hose nozzle Description LVS systems are specially designed for solvent dis- tillation / evaporation applications. They comprise an oil-free chemical duty diaphragm pump (MPC) with optional control packages, liquid containment and exhaust vapour condenser. All wetted parts are made from high quality chemically resistant materi- als with clear plastic coated glassware to allow sol- vent and acid vapours to be pumped. www.welchvacuum.com I 27

4 LVS Model options The LVS systems are available with a range of vacuum control options; unregulated, manually regulated and three different electronic control packages are available. Unregulated • When ultimate vacuum is required at all times. LVS 300 Z Manually regulated • A fine control valve is used to regulate the vacuum by acting as a bleed valve. Options available with one or two manual regulators. Standard digital control (cv) LVS 301 Z LVS 310 Z • The standard electronic control package uses a chemically resistant solenoid LVS 310 Z en valve to control the process vacuum while the pump runs continually. LVS 310 Z ef • The user defined vacuum and hysteresis levels are used to open and close the control valve thus maintaining vacuum at the process between the high and low control points. This is known as two point control. Economic digital control (en) • Economic control uses the same two point control system, but as cv replaces the control valve with a relay which turns the pump on and off to maintain the process vacuum between the user defined vacuum and hysteresis levels. This method greatly reduces power consumption and extends the lifetime of the pump. • Economic control is particularly useful for multi-user vacuum networks where the pump is located away from the user. Ecoflex digital control (ef) • Ecoflex control varies the speed of the pump constantly to maintain the user defined vacuum level regardless of changes in the process requirements. • The Ecoflex method exhibits genuine single point (hysteresis-free) control and therefore a stable vacuum level. • Single point control results in up to 40% increase in evaporation rates with mi- nimal bumping or foaming of precious samples. This is particularly important in ultimate rotary evaporation. 28 I www.welchvacuum.com

Highlight LVS 105 T - 10 ef Advantages LVS 105 T - 10 ef | 114184 • analytically pure, oil free vacuum • deep 2 mbar ultimate vacuum • Ecoflex vacuum control • built in solvent library • multi-lingual digital display • user friendly • heated pump heads to stop vapours condensing inside of the pump • designed for permanent operation • maintenance-free drive system and proven long dia- phragm life • fully chemically resistant • compact design • inlet separator to protect pump from liquid and particle ingestion • exhaust condenser for optimal solvent recovery Scope of delivery • Chemical duty diaphragm pump built inside casing • ON/OFF switch and internal protective thermal switch for the motor, mains cable and plug • Built in digital vacuum controller with ecoflex control software and solvent library • vibration isolating feet • inlet separator • exhaust condenser • pump head heating • 8mm inlet / exhaust hose nozzle Description ROdist professional package with LVS 105 T - 10 ef | 112033 The LVS 105 T - 10 ef is the perfect partner for your rotary evaporator, but can also be used for a range The Ecoflex control continuously adjusts the pum- of other applications such as vacuum ovens, solvent ping speed to match the vapour load of the process concentration and multi-user vacuum networks. Its and allows the pump to exhibit single point control deep 2 mbar ultimate vacuum and high free flow of which reduces bumping and foaming whilst achie- 20 l/min make it ideal for use with both high and low ving increased evaporation rates. The built in mul- boiling point solvents - even allowing non-volatiles ti-lingual digital vacuum controller allows easy ad- such as DMF to be evaporated at 30⁰C. It combines justment of the desired vacuum level as well as the a powerful built in chemical duty diaphragm vacuum option to select common solvents from the built in pump with Ecoflex control principals. Heating of the solvent library. An inlet trap protects the pump from pump heads allows a consistent clean vacuum wit- ingesting liquids and particles and an exhaust vapour hout gas ballasting. condenser is included for optimal solvent recovery. www.welchvacuum.com I 29

4 LVS Overview of Systems Flow rate / Free Connection Air Displacemant Types Ultimate Pressure Manual Ordering Vacuum Control Information Standard Two Point Vacuum Control Ecoflex Vacuum Control Economic Vacuum Control Number of Unregulated Connections Number of Manual Regulated Connections Number of Controller Regulated Connections With Dial Vacuum Gauge With Digital VCZ 521 Controller With LED VCZ 424 Controller m3/h mbar Welch Model 230V, Manual Regulated @50Hz 2 x LVS 105 T-10 ef 50/60Hz, 1 Ph Connections 1 x 114184 1.2 Controller Regulated 1.0 8 x LVS 101 Z w/ 1 x 115027 Connections gauge With Dial Vacuum x LVS 110 Z 1 x 115024 Gauge 2.0 2 x LVS 201 T 1 115037 With a Digital x Vacuum Controller LVS 201 T w/ 1 x 115037-10 gauge Simultaneous ope- ration of two inde- x LVS 210 T 1 x 115034 pendent vacuum processes 2.2 2 x LVS 210 T ef 1 x 115234 2.3 8 LVS 300 Z 1 115041 x LVS 301 Z 1 115047 x LVS 301 Z w/ 1 x 115047-10 gauge x LVS 302 Z 2 115043 x LVS 310 Z 1 x 115044 xx LVS 311 Z 11 x 115045 x LVS 320 Z 2 x 115046 2.6 8 x LVS 310 Z ef 1 x 115244 4.5 2 LVS 600 T 1 115051 x LVS 601 T 1 115057 x LVS 601 T w/ 1 x 115057-10 gauge x LVS 602 T 2 115053 x LVS 610 T 1 x 115054 xx LVS 611 T 11 x 115055 4.9 2 x LVS 620 T 2 x 115056 8.3 2 x LVS 610 T ef 1 x 115254 9.1 2 LVS 1210 T 1 x 115064 x LVS 1210 T ef 1 x 115264 x 2.3 8 Netvac LVS Systems LVS 310 Z en 1 x 115248-02 4.5 2 x LVS 610 T en 1 x 115258-02 x Every LVS system is supplied with a Chemical Duty Diaphragm Pump and a DN 8 hose connector. Some configurations also come with a vacuum control package and capture solvent recovery system depen- ding on your needs. Comes pre-assembled and ready to use. Comments Vacuum Control Ecoflex • Pump speed is automatically varied to control vacuum Manual • Vacuum is adjusted by user turning the regulator Economic • Pump automatically turns on/off based on demand for Standard Two Point Control • Vacuum is automatically controlled at set point using vacuum on/off solenoid valve 30 I www.welchvacuum.com

Technical Data Final pressure <8 mbar LVS 101 Z w/ LVS 110 Z LVS 300 Z LVS 301 Z LVS 301 Z w/ LVS 302 Z LVS 310 Z LVS 311 Z LVS 320 Z gauge gauge (424) Parameter Free Air Displacement, m³/h @ 50Hz 1,0 1,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 Free Air Displacement, 16,7 16,7 38 38 38 38 38 38 38 l/min <8 Ultimate pressure, <8 <8 <8 <8 <8 <8 <8 <8 Hose mbar nozzle DN8 Intake/Exhaust Hose nozzleHose nozzleHose nozzleHose nozzleHose nozzleHose nozzleHose nozzleHose nozzle connection DN8 DN8 DN8 DN8 DN8 DN8 DN8 DN8 Sound level < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 Dimensions (W/D/H), 360/310 360/310 360/310 360/310 360/310 360/310/ 360/310 360/310 360/310 mm /445 /445 /395 /445 /445 445 445 /445 /445 Weight, kg 11,60 11,70 16,1 16,30 16,30 16,3 17,8 18,1 18,4 Ordering Information 115027 115024 115041 115047 115047-10 115043 115044 115045 115046 230V 50/60Hz 115V 50/60Hz 115027-01 115024-01 115041-01 115047-01 115047-11 115043-01 115044-01 115045-01 115046-01 Final pressure <2 mbar LVS 201 T LVS 201 T LVS 210 T LVS 600 T LVS 601 T LVS 601 T LVS 602 T LVS 610 T LVS 611 T LVS 620 T LVS 1210 T w/gauge w/gauge (424) 1,8 4,5 4,5 4,5 Parameter 1,8 1,8 33 75 75 4,5 4,5 4,5 75 4,5 8,3 Free Air Displacement, 33 33 75 75 75 75 138 m³/h @ 50Hz Free Air Displacement, l/min Ultimate pressure, mbar < 2 < 2 < 2 < 2 < 2 < 2 < 2 < 2 < 2 < 2 < 2 Intake/Exhaust Hose Hose Hose Hose Hose Hose Hose Hose Hose Hose Hose connection nozzle nozzle nozzle nozzle nozzle nozzle nozzle nozzle nozzle nozzle nozzle DN8 DN8 DN8 DN8 DN8 DN8 DN8 DN8 DN8 DN8 DN8 Sound level < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 < 44 Dimensions (W/D/H), 360/310 360/310 360/310 360/310 360/310/ 360/310 360/310 360/310 360/310 360/310 540/310 mm /445 /445 /445 /395 445 /445 /445 /445 /445 /445 /445 Weight, kg 15,0 15,3 15,7 23,2 23,50 23,50 23,5 24,7 25,0 25,3 36,1 Ordering Information 115037 115037-10 115034 115051 115057 115057-10 115053 115054 115055 115056 115064 230V 50/60Hz 115V 50/60Hz 115037-01 115037-11 115034-01 115051-01 115057-01 115057-11 115053-01 115054-01 115055-01 115056-01 115064-01 Ecoflex LVS 310 Z ef LVS 105 T - 10 ef LVS 210 T ef LVS 610 T ef LVS 1210 T ef Parameter Free Air Displacement, m³/h @ 50Hz 2,6 1,2 2,2 4,9 9,1 Free Air Displacement, l/min Ultimate pressure, mbar 43 20 36 81 151 Intake/Exhaust connection Sound level <8 <2 <2 <2 <2 Dimensions (W/D/H), mm Weight, kg Hose nozzle DN8 Hose nozzle DN8 Hose nozzle DN8 Hose nozzle DN8 Hose nozzle DN8 < 44 < 44 < 44 < 44 < 44 360/310/445 250/260/435 360/310/445 360/310/445 540/310/445 19,9 9,5 19,0 26,8 37,1 Ordering Information - 114184 - - - 115244 - 115234 115254 115264 90...260VAC 115244-01 - 115234-01 115254-01 230V 50/60Hz - 115V 50/60Hz www.welchvacuum.com I 31

4 LVS Accessories & Configurations 700183-11 828857-18 828839 620637-01 Glassware Software Connection Kit CAT. No. Accessories for • For connection of PC to digital 700183-08 Exhaust condenser complete all LVS models controller in LVS systems 700183-11 Exhaust condenser complete LVS 105 T - 10 ef 828857-18 Drain all LVS condensor, with hose nozzle • Kit includes CD with software and DN 10, with KS 35 RS232 connection cable • CAT. No. 620637-01 828839 Receiving flask coated, 500ml 112575 828310-4 700300-02 Rotary Evaporator Kit Vacuum Hose Water Valve • Quick and easy connection to ro- • Red rubber vacuum hose, 8mm ID, • 2 way water flow valve for the tary evaporators 5mm wall thickness demand-responsive cooling water supply. • Kit includes 2m vacuum hose, coo- • CAT.No. 828310-4 ling water hose and clamps • Input: G 3/4 inch sleeve nut, • output: hose nozzle for hose inside • CAT. No. 112575 diameters 8 mm • CAT. No. 700300-02 32 I www.welchvacuum.com

5 Oil-Sealed Rotary Vane Pumps Oil-Sealed Rotary Vane Pumps P 4 Z | 322002 Advantages • high water vapour tolerance for chemical applications • compact, robust and functional construction • low noise emission • no oil contamination of the chamber by migration or suck-back • high pumping speed • free of non ferrous metals • low, ultimate pressures are reached quickly • long service intervals • low energy consumption • designed for permanent operation • rotary vanes made of a special plastic which are not affected by corrosion or damaged by dirt particles and have very good sliding properties Scope of Delivery Range of Applications • rotary vane vacuum pump ready-to-use with oil char- • vacuum drying ging • freeze drying • vacuum concentration • motor protection switch, main power switch, mains • Schlenk lines cable and plug • backing turbomolecular pumps • centering ring and clamping ring for inlet and exhaust • gas ballast valve • carrying handle • special oils available on request Fully reliable rotary vane pumps Due to their low weight, high pumping speed and compact housing construction for wipe cleaning The two-stage rotary vane pumps of the P - Z series these pumps are ideally suited for use in laboratories from Welch are characterized by their high water for applications within rough and fine vacuum ran- vapour tolerance and reliability. Welch Rotary Vane ges from 1 to 10-3 mbar. Pumps are designed to withstand large amounts of water vapour in the vacuum pump’s inlet vapour stream. This “water vapour tolerance” is the maxi- mum inlet pressure point at which the pump is able to operate with pure water / fluids and at the same time prevents them of condensing inside the pump. www.welchvacuum.com I 33

5 Oil-Sealed Rotary Vane Pumps Fully accessorized Packages Two Stage direct-driven rotary vane pump lab & freeze dryer packages P4Z • bench top with Dewar vessel, 77l/ min, 2x10-3 mbar, 230V, 50/60Hz, 1 Ph with Schuko, UK and US plug leads • CAT. No. 110009 P 4 Z SL package | 330041 P 6 Z FD package P 8 Z FD package P 12 Z FD package • with oil mist filter AKD, 2-way ball • with oil mist filter AKD, 2-way ball • with oil mist filter AKD, 2-way ball valve, hose adapter, PVC vacuum valve, hose adapter, PVC vacuum valve, hose adapter, PVC vacuum hose (1.5m), oil drain kit, 1 Liter spa- hose (1.5m), oil drain kit, 1 Liter spa- hose (1.5m), oil drain kit , 1 Liter re oil re oil spare oil • CAT. No. 330036 • CAT. No. 330037 • CAT. No. 330038 P 4 Z VC package P 6 Z SL package P 4 Z SL package • with oil mist filter AKD, inlet Sepa- • with PIZA 111 cr-gold, 2-way ball • with PIZA 111 cr-gold , 2-way ball rator, hose adapter, vacuum hose valve, oil mist filter OME 10/16, T- valve, oil mist filter OME 10/16, T- rubber red DN10 (3m), 1 Liter spare piece, hose adapter and rubber va- piece, hose adapter and rubber va- oil and oil drain kit cuum hose (3m), oil drain kit cuum hose (3m), oil drain kit • CAT. No. 330039 • CAT. No. 330040 • CAT. No. 330041 * FD - Freeze Dryer, VC- Vacuum Concentrator, SL - Schlenk Line 34 I www.welchvacuum.com

Connection Kits Kit 3, 4 Kit 7, 8 Kit 9, 10 Freeze Dryer Adapter Kits Vacuum Measurements Vacuum Control Packages Packages • All in one kit for connection to • Reliable and accurate measuring • A cost-effective package for cont- freeze dryer for a wide range of application rolling vacuum pressure up to 10-3 mbar (0.001 torr). Easy to adapt to • Adapter kits include 2-way ball val- • Vacuum measurement package in- two-stage rotary vane pumps. ve, hose connector, hinged clam- cludes PIZA 111 cr-gold handheld ping ring, centering ring, AKD oil gauge with stand, T-connection, • Vacuum control package includes mist seperator and 1.5m vacuum hinged clampong rings and cente- MRV 100 gauge with PIZA 111 cr- hose ring rings gold vacuum sensor, T-connection, solenoid valve, hinged clamping rings and centering rings Kit 3 | DN 16 | Cat. No. 330031 Kit 7 | DN 16 | Cat. No. 330051 Kit 9 | DN 16 | Cat. No. 330053 Kit 4 | DN 25 | Cat. No. 330032 Kit 8 | DN 25 | Cat. No. 330052 Kit 10 | DN 25 | Cat. No. 330054 Kit 11, 12 Kit 13, 14 Vacuum Pump Protection Chemical Trap Packages Package • Protect your rotary vane pump Pro- • Protect your rotary vane pump tect your rotary vane pump from from harmful vapours by trap- chemical vapours using acid neut- ping them in Dewar vessels ralisation trap • Vacuum pump protection packa- • Chemical trap package includes ge includes AKS inlet separator, acid neutralisation trap, elbow con- 2 Dewar vessels, connectors and nection, hinged clamping ring and flexible steel hose centering rings Kit 11 | DN 16 | Cat. No. 330055 Kit 13 | DN 16 | Cat. No. 330057 Kit 12 | DN 25 | Cat. No. 330056 Kit 14 | DN 25 | Cat. No. 330058 Kit 15 Kit 16 Vacuum Oven Kit Hose Kit with Hose Adapter • For easy connection of rotary vane • Hose kit for connection of rotary pump to vacuum oven vane pump to various apparatus • Vacuum oven kit includes 2.5m va- • Hose kit includes 8mm ID and cuum hose, hose connectors, hose 20mm ID vacuum hose (1.5m clamps, oil mist filter, 1 litre Labovac length each), hose connectors and 10 oil, hinged clamping rings and hose clamps centering rings Kit 16 | DN 16 | Cat. No. 330060 Kit 15 | DN 16 | Cat. No. 330059 www.welchvacuum.com I 35

5 Oil-Sealed Rotary Vane Pumps Chemvac 6 Z-101 | 109030 12 Z-301 | 109031 23 Z-301 | 109032 Chemvac Advantages The combination of a diaphragm pump with a rotary • corrosion optimised combination system vane pump was developed to take advantage of the • minimal oil contamination strong points of each type of pump. The two stage • extended oil life chemical duty diaphragm pump can withstand cor- • high chemical resistance rosive gasses and remove the resulting condensate • Labovac 14 oil for pumping solvent vapours prior to its absorption in the two stage rotary vane pump oil by constantly distilling the oil during ope- ration. The rotary vane pump provides a much lower ultimate vacuum and will have a long life with the pump oil being free of contaminates. Scope of Delivery: • rotary vane & diaphragm combination vacuum pump ready-to-use with oil charging • motor protection switch, main power switch, mains cable and plug • centering ring and clamping ring for inlet and exhaust • safety valve • oil mist separator • dial vacuum gauge for oil box • solvent trap Packages & Accesoires Accesoires CAT.No. Kit 5, Freeze Dryer & Vacuum Concentrator Adapter kit for Chemvac, DN 16 KF 330044 330045 Kit 6, Freeze Dryer & Vacuum Concentrator Adapter kit for Chemvac, DN 25 KF 800160 800135 Replacement Filter Element Labovac 10 oil, 1 litre (see page 37 for all vacuum pump oils) 36 I www.welchvacuum.com

RVP-Trolley RVP-Trolley Advantages The mobile laboratory rotary vane pump system has • trolley mounted for portability been specifically designed for use in chemistry labo- • Dewar vessels to protect pump from chemical vapours ratories. Its construction has intentionally been kept • AKD oil mist separator to capture any oil mist simple, compact and clearly arranged. Scope of Delivery: The upstream cold traps enable even larger quanti- ties of condensable vapours to be pumped without • rotary vane vacuum pump ready-to-use with oil char- any additional pump load. A PIZA 111 cr-gold Multi- ging and mounted on the trolley Range Vacuum Gauge for measuring the pressure can be easily attached to the to the stand rod. • motor protection switch, main power switch, mains cable and plug • gas ballast valve • oil mist separator • two Dewar vessels • PIZA 111 cr-gold handheld gauge (selected models) • connectors, flanges and flexible steel hose Types Description CAT.-No. P 4 Z - trolley with Dewar vessel, 77l/min, 2x10-3 mbar, 230V, 50/60Hz, 1 Ph with Schuko, UK and US 110008 plug leads P 4 Z - trolley system with Dewar vessel and vacuum gauge PIZA 111 cr-gold, 77l/min, 2x10-3 mbar, 230V, 110008-01 50/60Hz, 1 Ph with Schuko, UK and US plug leads Trolley system with Dewar vessel and vacuum gauge PIZA 111 cr-gold for various rotary vane pump sizes 110008-02 (use your own or choose one from our range) Trolley system with Dewar vessel for various rotary vane pump sizes (use your own or choose one from 110008-03 our range) *Trolley Systems are equipped with the new advanced chemical resistant vacuum gauge PIZA 111 cr-gold Rotary Vane Pump System, mobile www.welchvacuum.com I 37

5 Oil-Sealed Rotary Vane Pumps Technical Data Two-Stage Direct-Driven Rotary Vane Pumps Parameter UUnniitt PK 2DC P 4Z P 6Z P 8Z P 12Z P 17Z P 23Z P 40Z P 65Z 1,8 / 2,2 4,6 / 5,5 5,8 / 7,0 7,2 / 8,6 11,0 / 13,2 16,0 / 19,2 21,0 / 25,2 38 / 45,6 60 / 72 Pumping speed 50/60 Hz m3/h 30 / 36 77 / 92 97 / 116 120 / 144 183 / 220 267 / 320 350 / 420 633 / 760 1000/1200 to DIN 28426 part 1 (pneurop) l/min Ultimate pressure @ 50 Hz mbar 1 x 10-2 2 x 10-3 2 x 10-3 2 x 10-3 2 x 10-3 2 x 10-3 2 x 10-3 4 x 10-4 4 x 10-4 - without gas ballast total 0,5 1 x 10-2 1 x 10-2 1 x 10-2 3 x 10-3 3 x 10-3 3 x 10-3 1 x 10-2 1 x 10-2 - with gas ballast total mbar 33 Water vapour tolerance 60 60 60 35 35 35 33 50 IN connection - DN 16 KF DN 16 KF DN 16 KF DN 25 KF DN 25 KF DN 25 KF DN 25 KF DN 40 KF DN 40 KF EX connection dB (A) DN 16 KF DN 16 KF DN 16 KF DN 25 KF DN 25 KF DN 25 KF DN 25 KF DN 25 KF DN 40 KF Sound level Oil filling ml < 40 < 48 < 48 < 48 < 50 < 50 < 50 < 52 < 56 Frequency Hz 250 530 550 600 1000 800 820 1800 5500 Dimensions (W/D/H) mm 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 330 / 165 415 / 150 / 430 / 150 / 445 / 150 / 540 / 170 / 540 / 170 / 540 / 170 / 565 / 205 738 / 280 Weight kg / 170 235 235 235 260 260 260 / 296 / 423 Ordering information 17,5 19,5 21,5 100/115/230V 8,0 35,0 37,0 38,0 39,0 83,0 300/400V 230V - 322002 322003 322004 322005 322006 322007 - - 115V - - 322002-01 322003-01 322004-01 322005-01 322006-01 322007-01 322008 322009 322001 - - - -- - -- 322001-03 - - - -- - -- • Seal kit 302011 302081 302081 302081 302082 302082 302082 340006 340008 • Service kit - 302012-1 302075 302076 302077 302079 302080 302080 340007 340009 Accessories - - 320015 320015 320017 320017 320017 320017 - - • Separator AKD (pressure side) - 320016 320016 320018 320018 320018 320018 - - • Separator AKS (suction side) 700010 700010 700010 700011 700011 700011 700011 700013 700009 • Oil mist filter OME (pressure) 330044 330031 330031 330032 330032 330032 330032 - - • Freeze Dryer Adapter Kit Chemvac pumps Parameter P 6 Z - 101 P 12 Z - 301 P 23 Z - 301 Number of heads/stages 2/2 2/2 2/2 Free Air Displacement, m³/h 5,8 11 21 Free Air Displacement, l/min 97 183 350 Ultimate pressure, mbar Water vapor tolerance, mbar 2x10-3 2x10-3 2x10-3 Intake/Exhaust connection 70 80 45 Sound level, dB Dimensions (W/D/H), mm DN 16 KF DN 25 KF DN 25 KF Weight, kg 50 50 50 Ordering Information 500/330/340 590/345/420 590/345/420 230V 50/60Hz 25,5 42,5 46 109030 109031 109032 38 I www.welchvacuum.com

Intake Pressure / Pumping Speed - Diagrams P4Z P6Z P8Z www.welchvacuum.com I 39

5 Oil-Sealed Rotary Vane Pumps Accessories Description Size CAT. No. Oil Mist Separator AKD 16 DN 16 KF 320015 Oil Mist Separator AKD 25 DN 25 KF 320017 Description Size CAT. No. Inlet Condensor AKS 16 DN 16 KF 320016 Inlet Condensor AKS 25 DN 25 KF 320018 Description Size CAT. No. Oil Mist Filter OME 10/16 DN 16 KF 700010 Oil Mist Filter OME 10/25 DN 25 KF 700011 Description Size CAT. No. Condenser SS, water cooling SKS 40/25 700066 Condenser SS, water cooling SKS 40/16 700261 Description Size CAT. No. Hose Connector Adapter SS Hose Connector Adapter SS DN 16 KF - DN 12 701702 Hose Connector Adapter SS Hose Connector Adapter SS DN 25 KF - DN 20 701704 DN 25 KF - DN 12 710209 DN 16 KF - DN 20 701712-02 Description Size CAT. No. Fine Vacuum Adsorption Trap, SOF 16 Fine Vacuum Adsorption Trap, SOF 25, DN 16 KF 705179 DN 25 KF 705180 Description Size CAT. No. Exhaust Separator with Oil Return Kit DN 16 KF 705181 Exhaust Separator with Oil Return Kit DN 25 KF 705182 Description Size CAT. No. Male Hose Adapter Al DN 16 KF / 16mm 710052 Male Hose Adapter Al I.D. for PVC Hose DN 25 KF / 25mm 710053 I.D. for PVC Hose Description Size CAT. No. PVC Cord-Reinforced 16mm ID, 3.5mm 710058 Flexible Vacuum Hose, DN 16 wall thickness PVC Cord-Reinforced 25mm ID, 5mm 710059 Flexible Vacuum Hose, DN 25 wall thickness Description CAT. No. Replacement element for OME 10/16, OME 10/25, 800160 AKD 16 and AKD 25 Oil Drain/Change Starter Kit for One and Two-stage 340003 Rotary Vane Pumps (P*Z and P*E line) 40 I www.welchvacuum.com

Oil Labovac Use Welch pump oils to reduce oil change cycles and maximize performance. The warranty is only effective when using Welch qualified vacuum pump oils. Please note that for demanding applications not all types of Welch vacuum pump oil can be used. please contact your local Welch representative for further details. Labovac 10 - Mineral oil Labovac 11 - Synthetic oil Labovac 12S - Paraffin based mineral oil Standard oil for One and Two-Stage Welch Used for high operating temperatures > Rotary Vane Pumps and chemvac‘s . To 100°C, specially in One-Stage rough vacu- For pumping air, chemically inert perma- pump air, inert gas and noble gas. um rotary vane pumps. nent gases - water vapour, solvent vapors. Remarks: Remarks: Remarks: Oil service cycles can be extended by Do not pump any inorganic acids. Ultimate Oil service cycles can be extended by using an oil filter. pressure up to 0.5 mbar. using a chemical oil-filter. Pump should operated with a cold trap. Labovac 13 - PFPE oil Labovac 14 - Polyalphaolefin oil Vacuum Pump Oil (PAO) Condition Color For pumping strong oxidants like oxygen, ozone and reactive substances (halogens). For pumping of chemically inert perma- Vacuum Pump oil can become contami- Remarks: nent gases - water vapor and solvent va- nated with ingested fluids and vapors. Use Mixing with other types of oil must be ab- pors. Improved cold starting at low tem- recommended pump oil and change your solutely avoided. we recommend to order peratures. pump oil regularly. Cloudy and discolored the rotary vane pump directly with these oil will lead to premature pump failure. vacuuum oil to ensure best performance. Remarks: Make the clear choice and change your oil regularly. A oil-filter is strongly recommend. Ultima- te pressure up to 10-2 mbar. Good Bad (Possible Pump Damage) Ordering information 1 Liters (1.1qt) Labovac 10 Labovac 11 Labovac 12S Labovac 13 Labovac 14 2 Liters (2.1qt) Mineral oil Synthetic oil Paraffin based PFPE oil Polyalphaolefin 5 Liters (3.5qt) 10 Liters (10.6qt) 800122 800125 mineral oil 800131 (PAO) oil 20 Liters (21.2qt) - - 800132 200 Liters (1.2ba) - 800128 800133 800135 800120 - 800134 800136 800123 800126 - 800137 800124 800127 - 800138 800119 800129 - - 800130 - - - www.welchvacuum.com I 41

6 Additional Information Common Solvents Solvent Table Table indicates the required level of vacuum for evaporation at 40°C Solvent Formula Vacuum (mbar) at 40 °C acetone C3H6O 556 N-amylalcohol, C5H12O 11 n-pentanol C6H6 236 benzene C4H10 25 butanol C4H10O 130 tert. Butanol, CCI4 271 2-methyl-2-propanol C6H5CI 36 carbon tetrachloride CHCI3 474 chlorobenzene C6H12 235 chloroform C4H10O vacuum cyclohexane C2H4CI2 210 diethyl ether C2H2CI2 479 1,2-dichloro ethane C2H2CI2 751 1,2-dichloro ethylene (cis) C6H14O 375 1,2-dichloro ethylene (trans) C4H8O2 107 diisopropylether C3H7NO 11 dioxane C2H6O 175 DMF di methyl foramide C4H8O2 240 alcohol C7H16 120 ethyl acetate C6H14 335 heptane C3H8O 137 hexane C5H12O 14 isopropanol isoamyl alcohol, 243 337 3-methyl-1-butanol vacuum vacuum ethylmethylketone C4H8O 67 methanol CH4O 13 methylene chloride, dichlormethane CH2CI2 35 pentane C5H12 300 n-propyl alcohol C3H8O 53 pentachloro ethane C2HCI5 77 1,1,2,2, tetrachloroethane C2H2CI4 183 1,1,1, trichlorethylene C2H3CI3 72 tetrachloroethylene C2CI4 25 toluene C7H8 trichlorethylene C2HCI3 water H2O xylene C8H10 42 | www.welchvacuum.com

Repair/Warranty guideline All Returns – Warranty and Non-Warranty A Return Authorization (RA) number is re- For non-warranty returns and repairs the quired for all returns. Product returns wit- Customer pays for freight charges to and hout an RA will be refused at dock. from Welch; freight charges must be pre- paid. In addition to an RA number, all paid 1. repairs require a purchase order for the re- Go to www.ilmvac.com to obtain a Return pair work required. All paid repairs come Request (Damage Report) Form. Use this with a 90 day warranty. A nominal fee is as- form to list all chemicals that the equip- sessed for equipment that is inspected but ment could be contaminated with. This not repaired at the Customer’s discretion. information is required for the safety of For warranty returns and repairs freight repair personnel. A Return Authorization charges to Welch are prepaid by the cus- can not be issued until the risk of contami- tomer; Welch pays for return freight char- nation has been assessed by Welch. ges. Please explain observed performance issues on the Return Request form along 2. with purchase details. Your Welch product After reviewing your Return Request form, is warranted to be free from material and the Welch Repair Department will provide workmanship defects; warranty determina- you with the RA number and shipping in- tions are made at the time of inspection at structions. your Welch repair facility. 3. Decontaminate the equipment as indica- ted and package it in a suitable manner for transit. Damage caused by improper equipment packaging is the customer’s re- sponsibility. Insure the equipment against loss or damage. Prominently write the RA number on the outside of the packaging and again on the packing slip inside. Ple- ase also include a copy of the Return Re- quest form with the package. Ship the equipment to the address provided by the Repair Department. www.welchvacuum.com I 43

6 Additional Information Index - Alphabetical 6 Z-101 .................................................................................................................... 36 LVS 301 Z w/gauge ................................................................................... 30, 31 12 Z - 301 .................................................................................................................. 36 LVS 302 Z ...................................................................................................... 30, 31 23 Z - 301 ................................................................................................................. 36 LVS 310 Z ........................................................................................... 5, 28, 30, 31 Accessories .................................................................... 19, 25, 26, 32, 38, 40 LVS 310 Z ef .......................................................................................... 28, 30, 31 Advanced Vacuum Oven Kit ....................................................................... 26 LVS 310 Z en ................................................................................................ 28, 30 Aspiration .......................................................................................................... 4, 8 LVS 311 Z ......................................................................................................... 30, 31 biovac 106 ............................................................................................................... 8 LVS 320 Z ...................................................................................................... 30, 31 Chemical Duty Diaphragm Pumps ............................................. 20, 21, 22 LVS 600 T ...................................................................................................... 30, 31 Chemical Trap Packages ............................................................................... 35 LVS 601 T ................................................................................................ 18, 30, 31 ChemStar Dry ........................................................................................... 4, 9, 10 LVS 601 T / 610 T / en / ef ............................................................................ 16 Chemvac ................................................................................................... 9, 10, 36 LVS 601 T w/gauge ................................................................................... 30, 31 Condenser SS, water cooling ...................................................................... 40 LVS 602 T ...................................................................................................... 30, 31 Condensor ............................................................................................................ 40 LVS 610 T ............................................................................................ 5, 15, 30, 31 Configurations netvac ..................................................................................... 16 LVS 610 T ef ....................................................................................... 5, 15, 30, 31 Connection Kits ......................................................................................... 26, 35 LVS 610 T en ........................................................................................................ 30 Customized Solution ........................................................................................ 16 LVS 611 T ......................................................................................................... 30, 31 Diaphragm Pumps ..................................................................................... 18-21 LVS 620 T ...................................................................................................... 30, 31 Exhaust silencers .............................................................................................. 24 LVS 1210 T ...................................................................................................... 30, 31 Filtration / SPE ..................................................................................................... 7 LVS 1210 T ef ................................................................................................ 30, 31 Fine Vacuum Adsorption Trap ................................................................... 40 MP 030 Z ........................................................................................................ 17, 23 Freeze Dryer Adapter Kits ........................................................................... 35 MP 030 Z-EC ...................................................................................................... 23 Freeze Dryer & Vacuum Concentrator Adapter kit MP 055 Z ....................................................................................................... 23, 26 for Chemvac ....................................................................................................... 36 MP 065 ................................................................................................................... 26 Gauges ................................................................................................................... 25 MP 065 E ................................................................................................. 13, 22, 26 Gel Dryer ................................................................................................................ 12 MP 101 V .................................................................................................. 23, 24, 26 Glassware ...................................................................................................... 25, 32 MP 101 Z .................................................................................................. 23, 24, 26 Glove Box ............................................................................................................... 12 MP 105 E ......................................................................................................... 22, 26 handvac ................................................................................................................... 8 MP 201 E ................................................................................................................ 22 HBP ............................................................................................................................ 6 MP 201 T ................................................................................................. 23, 24, 26 HBP 101 ..................................................................................................................... 6 MP 301 E ......................................................................................................... 22, 26 Hose Connector Adapter .............................................................................. 40 MP 301 V ..................................................................................................23, 24, 26 Hose Kit with Hose Adapter ........................................................................ 35 MP 301 Z ................................................................................................. 23, 24, 26 LVS ................................................................................................................... 27–32 MP 601 E ................................................................................................. 22, 24, 26 Labovac 10 ................................................................................................... 35, 41 MP 601 T ................................................................................................. 23, 24, 26 Labovac 11 ............................................................................................................. 41 MP 901 Z ........................................................................................................ 23, 24 Labovac 12S ......................................................................................................... 41 MP 1201 E ............................................................................................... 22, 26, 24 Labovac 13 ............................................................................................................ 41 MP 1201 T ............................................................................................................... 23 Labovac 14 .................................................................................................... 36, 41 MP 1801 Z .............................................................................................................. 23 LVS 101 Z w/gauge .................................................................................... 30, 31 MP 2401 E ............................................................................................................. 22 LVS 105 T - 10 ef ................................................................ 4, 6, 29, 30, 31, 32 MPC 090 E .................................................................................. 4, 7, 20, 24, 26 LVS 110 Z ........................................................................................................ 30, 31 MPC 095 Z .................................................................................. 6, 11, 20, 24, 25 LVS 201 T ....................................................................................................... 30, 31 MPC 101 Z ............................................................................................. 5, 11, 21, 24 LVS 201 T w/gauge ................................................................................... 30, 31 MPC 105 T .............................................................................. 5, 6, 17, 20, 24, 25 LVS 210 T ...................................................................................... 5, 15, 27,30, 31 MPC 105 T iQ .......................................................................................... 5, 20, 25 LVS 210 T ef ............................................................................... 5, 15, 27, 30, 31 MPC 110 E ................................................................................................. 5, 20, 24 LVS 300 Z ............................................................................................. 28, 30, 31 MPC 155 Z .............................................................................................. 20, 24, 25 LVS 301 Z .................................................................................... 5, 16, 28, 30, 31 MPC 201 E ............................................................................................................ 20 LVS 301 Z / 310 Z / en / ef ............................................................................ 16 MPC 201 T ............................................................................................ 4, 5, 21, 24 44 I www.welchvacuum.com


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook