2015PRODUCTCATALOGPRODUCTS,INC. “TheCompanywithConnections®”LEARNING,ASSISTINGANDPROVIDINGPOSITIVESOLUTIONS

Table of ContentsProduct Specifications …………………………………………………………………………………………………..…….… 4Dimensional Data Sheet ……………………………………………………………………………………………….…….…. 5A-LOK Guarantee …....………………………………………………………………………………………………….……..... 9A-LOK Premium (ASTM C-923)………………………………………………………………………………………..…….…10A-LOK Premium (ASTM F-2510) …………………………………………………………………………………….…….…..12A-LOK STM …………………………………………………………………………………………………………….…….…..14X-CEL ………………………………………………………………………………………………………………….…….……16Inserta-LOK ……………………………………………………………………………………………………….………….…..18Magnetic Mandrel System …………………………………………………………………………………………………..….20A-LOK Field Sleeves …………………………………………………………………………………………………………....21A-LOK Field Sleeve Installation Instructions……………………………………………………………………….……….…22X-CEL / Z-LOK Pipe Installation Instructions …………………………………………………………………………………23GrandSlam Lube ………………………………………………………………………………………………………………...24Water-Stop ……………………………………………………………………………………………………………………….26A-LOK Water-Stop Gasket Installation Guide ………………………………………………………………………………..28Low Draft/Minimum Taper Hole Formers …………………………………………………………………………….………..29G3 Boot System ……………………………………………………………………………………………………….…………30Z-LOK Cast-In Boot Connector ………………………………………………………………………………………….……..32Maximum Parallel Pipe Layout for Z-LOK Mandrels………………………………………………………………….……...34Z-LOK STM ……………………………………………………………………………………………………………………...35Quik-LOK …………………………………………………………………………………………………………………………39Installing Quik-LOK on a Mandrel……………………………………………………………………………………….……...41Septic Tank Connectors ………………………………………………………………………………………………….……..42Raider Septi-Seal …………………………………………………………………………………………………………….….43Dura-Plate 100 Manhole Liner System ………………………………………………………………………………………. 45Water-LOK ………………………………………………………………………………………………………………………. 51Dura-Plate 100 Epoxy Mortar …………………………………………………………………………………………………. 53Butyl-LOK Sealant Systems …………………………………………………………………………………………………... 55A-LOK Primary Precast Invert System ………………………………………………………………………………………. 59Tru-Contour Secondary Precast Invert System …………………………………………………………………………….. 61

Key-LOK Lifting System ……………………………………………………………………………………………………...... 63Lift Insert Holders ……………………………………………………………………………………………………………..... 66Lift Insert Capacity ……………………………………………………………………………………………………………… 67Concrete Reinforcement Spacers ……………………………………………………………………………………………. 68Hoop Supports ………………………………………………………………………………………………………………….. 70Bolt Slot Anchors ……………………………………………………………………………………………………………….. 72Avanti Multigrout ………………………………………………………………………………………………………………... 74Flex-LOK Step Inserts …………………………………………………………………………………………………………. 82“Big boxes, big seals” article ………………………………………………………………………………………………….. 83“World’s Largest Flexible Pipe to Manhole Seal” article ………………………………………………………………...… 84“Flexible Storm Sewer Connector Introduced in Orlando” article ………………………………………………………… 86Save Money for Vermont Towns” article …………………………………………………………………………………….. 87“Civil Engineering” article ……………………………………………………………………………………………………... 89“Big Beaver Rd. sanitary relief sewers installed” article …………………………………………………………………… 93

PRODUCT SPECIFICATIONS – 2015Learning, Assisting and Providing Positive SolutionsCOMPRESSION FIT PIPE TO MANHOLE CONNECTORS APPLICATIONS •Flexible watertight connector for sanitary or storm.A•LOK PREMIUM SIZE/RANGE Omni-directional Deflection •Performance watertight connector for sanitary, storm and lightA•LOK X•CEL 8.50\"-102.00\" 10 Degrees 4.25\"-102.00\" 10 Degrees industrial demand. •Watertight connector for storm and light industrial demand.A•LOK STM 8.50\"-102.00\" 10 Degrees •Watertight connector for cored or cast openings in new or in situ-INSERTA•LOK 4.25\"-16.00\" 7 Degrees type construction.BOOT TYPE PIPE TO MANHOLE CONNECTORSZ•LOK 1.25\"-21.25\" 25 Degrees •Cast-in place watertight connector for sanitary, storm and lightG-3 3.50\"-13.50\" 15 Degrees industrial demand.Z•LOK STM/Smooth-Wall 14.00''-102.00'' 15 Degrees/MinimumZ•LOK STM/Corrugated 14.50''-41.50'' 15 Degrees/Minimum •Expanded-in-place watertight connector for watertight, storm andQUIK•LOK 4.00''-13.00'' 20 Degrees sanitary demands with attached take-down clamp. •Cast-in place watertight connector for storm or sanitary systems. using smooth wall or corrugated pipe. •Cast-in place watertight connector for sanitary, storm and light industrial demand with attached take-down clamp.SEPTIC TANK CONNECTORS – BOOT STYLE & COMPRESSIONA•LOK SEPTIC SEAL 1.5\"-4.50\" 7 Degrees •Compression watertight connector for septic structures.QUIK•LOK SEPTIC SEAL 4.00''-6.00'' 10 Degrees •Cast-in boot style watertight connector for septic structures with attached take-down clamp.GROUTED IN CONNECTIONSWATER•STOP 4.25\"-120.00\" •Designed for NEW or EXISTING stormwater structures to seal cold joint pipe penetrations, creating a watertight and soil-tight seal between pipe and connector. Provides a surface for concrete and grout to adhere. For all smooth-wall or HDPE corrugated pipe.CORROSION RESISTANT LINERSDURA-PLATE 100 SIZE/RANGE Minimum Thickness •Extra strong PVC interior protection for round concrete structures from 48.00\"-144.00\" 65 Mils hydrogen sulfide and other acidic conditions in wastewater, and light industrial structures.DURA-PLATE 100 EPOXY MORTAR •3 part epoxy resin provides concrete and masonry surfaces with increased chemical resistance.GRADE RING SEALS SIZE/RANGE Height Adjustment CapabilitiesWATER•LOK 24\" and 30\" .00\"-14'' •Telescoping, flexible, watertight grade•ring protective liner system for manholes.SPACERS & REINFORCEMENT ACCESSORIESNon-Corrosive plastic Pyramid•LOK spacers and metal spacers for round, arch and elliptical pipe, manholes, box sections, catch basins,septic tanks and cast-in place products. Hoop Supports to hold single wire reinforcement in place.KEY•LOK LIFT SYSTEMCertified manhole lifting system for wall thickness up to 6.00\" and weights up to 6,500 lbs.Includes: KEY•LOK Lift Inserts, Lift Insert Holders, Lift Pins and Lift Bars.INVERT CHANNELING EQUIPMENTA•LOK PRIMARY SYSTEM SIZE RANGE Increments •Mono-lithic pour casting equipment for wastewater and storm structures.TRU-CONTOUR 8\", 10\", 12\" 7 Degrees •Secondary pour casting equipment for wastewater and storm 4.00\"-48.00\" Available in SECONDARY SYSTEM 2 Degree increments structures.ADDITIONAL A•LOK PRODUCTSHOLE FORMERS - METAL & FIBERGLASS BUTYL•LOK SEALANTS MAGNETIC: STEP INSERT HOLDERS,MANDRELS GRANDSLAM LUBE MANDRELS, HOLE FORMERSVERTITE ELASTOMERIC SEALS FOR PIPES BOLT SLOT ANCHORS BONDUIT CONCRETE ADHESIVE CAST-IN-PLACE FIELD SLEEVES OR MANHOLES SQUARE & ROUND STEP INSERTSAVANTI GROUT REPAIR SEALANTS KELLY’S CONCRETE DISSOLVERVisit our website - www.a-lok.com Copyright 2015 © A•LOK Products, Inc.800-822-2565 • 215-547-3366 • FAX 215-547-5260P.O. Box 1647 • Tullytown, PA 19007 • [email protected]

DIMENSIONAL DATA SHEET A•LOK® X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT A•LOK® A•LOK® Mandrels Field Sleeves CONNECTOR NOMINAL CONNECTOR Round FlatCROSS / MANDREL PIPE OD / MANDREL Round Flat NOTES XXSECTION NUMBER +/- 0.25” I.D. XX XX *140 4.25” 3.25” X X XX XX *150 4.50” 3.50” X X XX *160 4.75” 3.75” X X XX XX *165 5.00” 4.00” X X XX XX *170 5.25” 4.25” X X XX XXxx92 185 5.75” 4.75” XX XX *200 6.25” 5.25” XX XX *210 6.50” 5.50” X X XX XX *225 6.875” 5.875” X X XX XX *235 7.25” 6.25” X X XX XX 240 7.50” 6.50” X X XX XX 255 7.82” 6.82” X X XX XX *285 8.50” 7.00” X X XX XX *300 9.00” 7.50” X X XX *310 9.25” 7.75” X X XX *320 9.50” 8.00” X X XX 325 9.75” 8.25” X X XX XX 330 10.00” 8.50” X X XX 340 10.25” 8.75” X X XX XX *350 10.50” 9.00” X X 355 10.75” 9.25” X X *370 11.25” 9.75” X X 380 11.50” 10.00” X X *385 11.75” 10.25” X X 390 12.00” 10.50” X X 400 12.25” 10.75” X Xxx93 *410 12.50” 11.00” XX 415 12.75” 11.25” XX *425 13.00” 11.50” X X 440 13.25” 11.75” X X 455 14.00” 12.50” X X 470 14.25” 12.75” X X 475 14.375” 12.825” X X 480 14.75” 13.25” X X 490 15.25” 13.75” X X 500 15.50” 14.00” X X 520 16.00” 14.50” X X 525 16.25” 14.75” X X 535 16.50” 15.00” X X 540 16.625” 15.125” X X 560 17.00” 15.50” X X 570 17.50” 16.00” X XIMPORTANT – THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING ANORDER FOR CONNECTORS AND EQUIPMENT TO INSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT TOMANUFACTURERS TOLERANCE.MANDREL AND FIELD SLEEVE LISTED WITH “X” ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURECONFIGURATIONS. ITEM WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.WEB: WWW.A-LOK.COM • E-MAIL: [email protected] • PHONE 1-800-822-2565November, 2011 – SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET A•LOK® X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT A•LOK® A•LOK® Mandrels Field Sleeves CONNECTOR NOMINAL CONNECTOR Round Flat CROSS / MANDREL PIPE OD / MANDREL Round Flat NOTESSECTION XX NUMBER +/- 0.25” I.D. X XX 580 18.00” 16.50” X X X 600 18.50” 17.00” X X X X 610 18.75” 17.25” X X X 620 19.125” 17.625” X XX XX 630 19.50” 18.00” X X XX X 635 19.75” 18.25” X X XX X 640 20.00” 18.50” X X XX XX 650 20.25” 18.75” X X XX XX 660 20.50” 19.00” X X XX 675 21.00” 19.50” X X X XX 690 21.375” 19.875” X X XX X 700 21.437” 19.937” X XX XX 710 22.00” 20.50” X X XX 720 22.50” 21.00” X X XX 740 23.00” 21.50” X X XX XXxx93 750 23.50” 22.00” X X X 770 24.00” 22.50” X X X XX 780 24.50” 23.00” X X X XX 800 24.75” 23.25” X X XX XX 805 25.00” 23.50” X X XX 815 25.50” 24.00” X X 820 25.75” 24.25” X X 840 26.00” 24.50” X 850 26.50” 25.00” X X 855 26.75” 25.25” X X 860 27.00” 25.50” X 870 27.50” 26.00” X X 890 28.00” 26.50” X X 900 28.25” 26.75” X 915 28.50” 27.00” X X 920 28.75” 27.25” X 930 29.00” 27.50” X 970 30.00” 28.00” X X 980 30.50” 28.50” X 1000 30.75” 28.75” X 1020 31.25” 29.25” X Xxx94 1030 31.50” 29.50” X X 1035 31.625” 29.625” X X 1040 32.00” 30.00” X X 1050 32.375” 30.375” X X 1070 32.875” 30.875” X X 1090 33.50” 31.50: X XIMPORTANT – THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING ANORDER FOR CONNECTORS AND EQUIPMENT TO INSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT TOMANUFACTURERS TOLERANCE.MANDREL AND FIELD SLEEVE LISTED WITH “X” ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURECONFIGURATIONS. ITEM WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.WEB: WWW.A-LOK.COM • E-MAIL: [email protected] • PHONE 1-800-822-2565November, 2011 – SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET A•LOK® X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT A•LOK® A•LOK® Mandrels Field Sleeves CONNECTOR NOMINAL CONNECTOR Round FlatCROSS / MANDREL PIPE OD / MANDREL Round Flat NOTES XSECTION NUMBER +/- 0.25” I.D. X 1100 33.80” 31.75” X X XX XX 1110 34.25” 32.25” X X XX XX 1130 35.00” 33.00” X X XX 1140 35.25” 33.25” X X X XX 1160 35.75” 33.75” X X X 1180 36.25” 34.25” X X X X 1200 37.00” 35.00” X X XX 1210 37.50” 35.50” X X X XX 1220 37.70” 35.70” X X XX XX 1230 38.00” 36.00” X X XX 1235 38.375” 36.375” X X XX XX 1240 38.50” 36.50” X X X X 1250 38.75” 36.75” X XX 1260 39.00” 37.00” X X X 1280 39.50” 37.50” X X XX 1310 40.50” 38.50” X X XX XX 1320 40.75” 38.75” X XX 1330 41.125” 39.125” X X XX 1350 42.00” 40.00” X X 1360 42.25” 40.25” X Xxx94 1370 42.50” 40.50” X X 1390 43.25” 41.25” 1420 44.00” 42.00” X X 1430 44.50” 42.50” X X 1470 45.50” 43.50” X X 1475 45.75” 43.75” X 1480 46.00” 44.00” X 1500 46.625” 44.625” X 1520 47.25” 45.25” X 1530 47.50” 45.50” X 1540 48.00” 46.00” X X 1560 48.375” 46.375” X X 1570 49.00” 47.00” X 1600 49.75” 47.75” 1610 50.00” 48.00” 1625 50.50” 48.50” X X 1630 50.75” 48.75” X X 1640 51.00” 49.00” X X 1650 51.50” 49.50” X 1670 52.00” 50.00” X 1690 52.50” 50.50” X X 1700 52.75” 50.75” XIMPORTANT – THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING ANORDER FOR CONNECTORS AND EQUIPMENT TO INSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT TOMANUFACTURERS TOLERANCE.MANDREL AND FIELD SLEEVE LISTED WITH “X” ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURECONFIGURATIONS. ITEM WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.WEB: WWW.A-LOK.COM • E-MAIL: [email protected] • PHONE 1-800-822-2565November, 2011 – SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.

DIMENSIONAL DATA SHEET A•LOK® X-CEL, PREMIUM & STM CONNECTOR / EQUIPMENT A•LOK® A•LOK® Mandrels Field Sleeves CONNECTOR NOMINAL CONNECTOR Round FlatCROSS / MANDREL PIPE OD / MANDREL Round Flat NOTES XSECTION NUMBER +/- 0.25” I.D. XX 1705 53.00” 51.00” X X 1710 54.00” 52.00” X X X XX 1745 54.50” 52.50” X X X 1790 56.00” 54.00” X XX 1820 56.875” 54.875” X X XX Xxx94 1830 57.00” 55.00” X X X X 1840 57.50” 55.50” X XX XX 1850 57.75” 55.75” X 1860 58.00” 56.00” X X X 1870 58.375” 56.375” X XX 1910 59.50” 57.50” X X X 1920 60.00” 57.50” X XX XX 1930 61.50” 59.00” X XX 1940 62.00” 59.50” X XX 1970 63.00” 60.50” X X X 2040 65.00” 62.50” X X X X 2050 65.50” 63.00” X X 2060 65.75” 63.25” 2070 66.00” 63.50” X 2080 66.50” 64.00” X X 2140 67.00” 64.50” X 2160 67.625” 65.125” X X 2170 68.00” 65.50” 2210 69.375” 66.875” X X 2300 72.00” 69.50” X X 2310 72.375” 69.875” Xxx95 2360 73.50” 71.00” X X 2430 75.50” 73.00” X X 2520 79.00” 76.50” X 2560 80.50” 78.00” X 2600 81.50” 79.00” 2740 86.00” 83.50” 2750 86.25” 83.75” 2800 87.50” 85.00” X X 2820 88.75” 86.25” 2840 89.25” 86.75”IMPORTANT – THE TYPE AND OUTSIDE DIAMETER (OD) OF THE PIPE WILL BE REQUIRED WHEN PLACING ANORDER FOR CONNECTORS AND EQUIPMENT TO INSURE PROPER SELECTION. ALL DIMENSIONS SUBJECT TOMANUFACTURERS TOLERANCE.MANDREL AND FIELD SLEEVE LISTED WITH “X” ARE CURRENTLY AVAILABLE FOR STANDARD STRUCTURECONFIGURATIONS. ITEM WITH BLANKS WILL REQUIRE REVIEW BEFORE ORDERING.WEB: WWW.A-LOK.COM • E-MAIL: [email protected] • PHONE 1-800-822-2565November, 2011 – SUPERCEDES ALL PREVIOUS INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE.



The Company With Connections® TMTHE NEXT LEVEL OF FLEXIBLE CONNECTORSA-LOK® PREMIUM™ ASTM C-923 APPLICATIONA•LOK® PREMIUM™ KEY ADVANTAGES (Continued)Designed to produce a Precast Concrete material will react by redistributing and equalizing the blended materialsguaranteed watertight Manhole to maintain its proper sealing compression.seal between pipe andconcrete, the A•LOK® Smooth Wall Close-up View A specific combination of fibers and congealing agents have beenPremium™ flexible pipe- Pipe Showing selected to prevent the escape or loss of material through absorption orto-manhole connector from minor punctures or tears that could occur during the initial couplingprovides maximum Connectors of the connector and during its service life.performance on the job Flexibilitysite. Its unique design Benefits and advantages include:not only saves valuableproject time, but also 1. Functioning on pure compression, the A•LOK® Premium™ allows forensures longevity and fast and easy field installation. After the pipe is beveled and theoffers unsurpassed connector and pipe are cleaned and lubricated, the pipe is simplyenvironmental benefits. centered in the connector and inserted. Backfilling can be done immediately, thus enhancing project safety and overcoming theA•LOK® Premium™ Cast in A-LOK® Premium™ Connector. typical problems of water, running sand and other unstable trench conditions.connectors prevent For all types of smooth wall pipe. 2. Efficient geometry of the profile lowers the coupling force required toinfiltration and insert the pipe into both radius and flat wall connector designs. Lower coupling force translates into quicker and easier installation.ex-filtration into wastewater or stormwater systems, and are installed 3. Increased nominal pipe diameter tolerance over conventionalin the precast structure in a way that does not require coring or compression connector designs while still maintaining up to 10 degrees of omnidirectional axial deflection.placement after the base component is cast. This eliminates residual 4. Dynamic self-sealing core material can compensate for changes inwaste from coring, disposal of the slugs or wasted raw material dimensions and physical eccentricity.utilization or energy. Once cast-in, the connector becomes an integral 5. Available in a range of sizes from 8” through 48” utilizing existing A•LOK® mandrels.component of the structure wall. 6. Backed by standard A-LOK Watertight Guarantee.A•LOK® Premium™ has demonstrated in tests that it will meet and 7. Like other A•LOK® connectors on larger-diameter pipe where sizeexceed 13 psi of hydrostatic water pressure. prohibits a gasket from being installed in a flat plane, the A•LOK® MATERIAL Premium can be configured for casting in a curve with the connector staying perpendicular to the center line of the pipe. DiscoveredExtruded from compounds formulated for wastewater applications through years of extensive research and development, thisand engineered to conform to the requirements of configuration causes no loss of compression or deflection.section 4.1.1 of ASTM C-923, the standard rubber connector isavailable in alternative compounds upon request. Contact an A•LOK® PRODUCT REFERENCESrepresentative regarding special applications, such as the presence ofhydrocarbons. A.) ASTM C-923 Resilient Connector Between Reinforced Concrete KEY ADVANTAGES Manholes Structures, Pipe and Laterals.The external appearance of the A•LOK® Premium™ connector appears to B.) ASTM C-1244be a standard connector, but under differential loading or pipe deflection Standard Test Method For Concrete Sewer Manholesit will instantaneously react and redistribute its visco-elastic dynamic by the Negative Air Pressure (Vacuum) Testcore material to maintain its circumferential sealing pressure. Thisvisco-elasticity behavior is made possible by introducing a blend of C.) ASTM C-478environmentally friendly fibers, binders, polymers and congealing agents Standard Specification for Precast Reinforced Concreteinto the connector core which provides a controllable and dynamic Manhole Sectionsviscose fluid within the connector. In most installations, this material willremain equally distributed throughout the core of the connector providedproper pipe bedding practices have taken place. In the event that short-term or long-term settlement of the pipe begins to occur, the core

PERFORMANCE STANDARD PRODUCT SPECIFICATIONSThe A•LOK® Premium™ connector is guaranteed to meet or exceed all A flexible pipe to manhole connector shall be used whenever a pipe penetratesmaterial and test requirements outlined in ASTM C-923 “Resilient into a precast concrete manhole or structure. The connector shall be The A•LOK®Connectors Between Reinforced Concrete Manhole Structures and Premium™ Connector as manufactured by A•LOK Products, Inc., Tullytown, PA orLaterals”. approved equal. The design of the connector shall provide a flexible, watertight seal between theExtruded from compounds formulated for wastewater applications, the pipe and concrete structure. The connector shall assure that a seal is maderubber connector is engineered to conform to the requirements of ASTM between:C-923. Alternative compounds are available upon special request. 1. The connector and the structure wall by casting the connector integrally with the structure wall during the manufacturing process in a manner that it will notRESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923 pull out during pipe coupling. The connector shall also be capable of being cast into a round structure by curving the connector in a manner that allows it toTEST RESULTS ASTM METHOD remain centrally located within the structure wall and perpendicular to the pipe.Chemical resistance at 22°C for 48h This configuration will result in no loss of seal or deflection of pipe entering a no weight loss concrete structure. 1 N Sulfuric acid no weight loss D 412 2. The seal between the connector and the pipe shall be made by the 1 N Hydrochloric compression of the connector between the outside circumference of the factory Acid 1200 psi or D 2240 installed smooth oversleeve of a corrugated pipe or the smooth surface of aTensile strength 8.5 MPa, min (Shore A traditional pipe and the interior hole opening of the structure. The connector shallElongation at break 350% min. durometer) be the only component to affect the seal between the pipe and structure.Hardness ±5 from mfg’s. D 573, The connector shall be made from materials that conform to the physical and specified hardness 70±1°C for Section 4, “Materials and Manufacture” of ASTM C-923 Standard SpecificationAccelerated 7 days for Resilient Connectors Between Reinforced Concrete Manhole Structures andoven-aging decr. of 15%, Laterals”, and the overall design will meet or exceed Section 7, “Test Methods and max. of original D 395, Method B, Requirements” of ASTM C-923. This connector shall be sized specifically for theCompression set tensile strength, at 70°C for 22h type of pipe being used and shall be installed in accordance with the decr. of 20% D 471, immerse recommendations of the manufacturer.Water absorption max. of elongation 0.75 by 2-in. or decr. of 25%, 19 by 25-mm IN THE FIELD PIPEOzone resistance max. of original Specimen in INSTALLATION INSTRUCTIONSLow-temp deflection distilled waterbrittle point increase of 10%, at 70°C for 48h STEP 1:Tear resistance max. of original D 1171 Confirm that the pipe surface is smooth, clean by weight D 746 and free of foreign materials, chips, gouges and D 624, Method B form seams due to manufacturing or handling. rating 0 Slightly bevel any sharp or blunt edges caused by no fracture at the cutting of the pipe. -40°C 200 lbf/in. STEP 2: or 34 kn/m Lubricate the connector and the entire section of the pipe that will be inserted into theCopyright ASTM INTERNATIONAL. Reprinted with permission connector. The chart below lists A-LOK’s minimum lubrication length “L”.DIMENSIONAL DATA PIPE SIZE MIN. LUBRICATION LENGTH “L” 8” - 15” 12” Maximum Pipe O.D. Based on Manhole 16” - 18” 18” Diameter and Pipe Angles Using 21” & Larger 24” A•LOK® Premium™ Connectors. STEP 3: Center the pipe and connector square to each other and insert the pipe into the connector using a bar or back hoe depending on the size. Once the pipe is coupled with the connector, deflect the structure or pipe to achieve the proper angle. MAX. PIPE SIZE OD’s WARNING To ensure the A-LOK® Premium™ Connector Manhole 135° - 225° 90° remains a flexible watertight connector, it is A- Diameter Pipe Angle Pipe Angle LOK Products, Inc. strong recommendation that no mortar be placed between the pipe and wall 42” 26.5” 22.0” of the concrete structure. The use of mortar in this 48” 31.5” 25.0” area would decrease the effectiveness of the 60” 42.0” 32.0” connector to compensate for shear caused by 72” 52.5” 38.0” settlement or ground movement. 84” 59.5” 44.0” 96” 73.5” 50.0” CAUTION: NOTE: 108” 76.0” 56.0” To find approximate subgrade, measure from the 120” 85.0” 62.0” When installing pipe stubs outside base of the structure to the junction of the for future pipeline installation, connector and flat spot. Then add the wall all stubs must be properly thickness of the pipe plus 1/4 inch. restrained to prevent anyMin. distance between pipes is movement by means otherapprox. 1/2 the smallest pipe OD than the A-LOK® Premium™Connector.© 2009 A-LOK Products, Inc. Supercedes all previous literature P.O. BOX 1647 • 697 MAIN STREET • TULLYTOWN, PA 19007• [email protected] BY ISSUED AND/OR PENDING PATENTS 800-822-2565 • 215-547-3366 • 215-547-5260 FAX • www.a-lok.com

The Company With Connections® TMTHE NEXT LEVEL OF FLEXIBLE CONNECTORSA-LOK® PREMIUM™ ASTM F-2510 APPLICATIONA•LOK® PREMIUM™ KEY ADVANTAGES (Continued)The A•LOK® Premium™ Precast Concrete remain equally distributed throughout the core of the connector providedis a flexible compression Manhole proper pipe bedding practices have taken place. In the event that short- term or long-term deflection of the pipe begins to occur, the core materialconnector designed to be Smooth will react by redistributing and equalizing the blended materials tointegrated into a Oversleeve maintain its proper sealing compression.watertight system based A specific combination of fibers and congealing agents have beenon ASTM F-2510. When selected to prevent the escape or loss of material through absorption orused with a corrugated from minor punctures or tears that could occur during the initial couplingpipe with a factory HDPE Close-up View of the connector and during its service life.installed smooth Corrugated Pipe Showingoversleeve or with a A•LOK® Premium™ has successfully been tested to ASTM F-2510 Installed in Connectors deflection requirements of 5% without loss of seal. Connector Flexibility Benefits and advantages include:smooth wall pipe, theA•LOK® Premium™ will 1. Functioning on pure compression, the A•LOK® Premium™ allows forprovide a guaranteed fast and easy field installation. After the pipe is beveled and thewatertight seal between connector and pipe are cleaned and lubricated, the pipe is simplythe pipe and the wall of a Smooth centered in the connector and inserted. Backfilling can be doneconcrete structure. Its Oversleeve immediately, thus enhancing project safety and overcoming theunique design not only typical problems of water, running sand and other unstable trenchprovides maximum A-LOK® Premium™ Connector making a conditions. watertight connection with HDPE 2. Efficient geometry of the profile lowers the coupling force required to Corrugated Pipe using a factory installed insert the pipe into both radius and flat wall connector designs.performance but saves smooth oversleeve. Lower coupling force translates into quicker and easier installation.valuable project time, extends the longevity of the structures and 3. Increased nominal pipe diameter tolerance over conventionalreduces the projects overall environmental impact. compression connector designs while still maintaining up to 10 degrees of omnidirectional axial deflection.A•LOK® Premium™ connectors prevent infiltration and ex-filtration aboutthe pipe interface in wastewater or stormwater systems. They are 4. Connector can meet the 5% deflection requirements of ASTM F-installed in the structure in a way that does not require coring or 2510 without loss of seal or compression. Dynamic self-sealingplacement as a secondary operation. This eliminates residual waste from core material can compensate for changes in dimensions andcoring, the disposal of the slugs, inefficient raw material utilization and physical eccentricity.excess energy use. Once cast-in, the connector becomes an integralcomponent of the structure’s wall. 5. Available in a range of sizes from 8” through 48” utilizing existing A•LOK® mandrels. MATERIAL 6. Backed by standard A-LOK Watertight Guarantee.The connectors are extruded from rubber compounds that are formulated 7. Like other A•LOK® connectors on larger-diameter pipe where sizefor wastewater applications and engineered to conform to the prohibits a gasket from being installed in a flat plane, the A•LOK®requirements of ASTM F-2510. The A•LOK® Premium™ connector is Premium can be configured for casting in a curve with the connectoralso available in alternative rubber compounds upon request. Please staying perpendicular to the center line of the pipe. Discoveredcontact an A•LOK® representative regarding additional benefits and through years of extensive research and development, thisspecial applications, such as the presence of hydrocarbons. configuration causes no loss of compression or deflection.DEFLECTION PERFORMANCE PRODUCT REFERENCESAxial Deflection of Pipe (Angular) - 10 degrees A.) ASTM F-2510 – Standard Specification for Resilient Connectors Between Reinforced Concrete ManholeOutside Diameter of Pipe Deflection from Loading: 5% in accordance to Structures and corrugated High Density Polyethylene Pipes.ASTM F-2510 B.) ASTM C-478 – Standard Specification for Precast KEY ADVANTAGES Reinforced Concrete Manhole Sections.The external appearance of the A•LOK® Premium™ connectors appear to C.) ASTM C-913 – Standard Specification for Precast Concretebe a standard connector, but under differential loading or pipe deflection Water and Wastewater Structures.it will instantaneously react and redistribute its visco-elastic dynamiccore material to maintain its circumferential sealing pressure. Thisvisco-elasticity behavior is made possible by introducing a blend ofenvironmentally friendly fibers, binders, polymers and congealing agentsinto the connector core which provides a controllable and dynamicviscose fluid within the connector. In most installations, this material will

PERFORMANCE STANDARD PRODUCT SPECIFICATIONSThe A•LOK® Premium™ connector is guaranteed to meet or exceeds all A flexible pipe to manhole connector shall be used whenever a pipe penetratesmaterial and test requirements outlined in ASTM F-2510 “Resilient into a precast concrete manhole or structure. The connector shall be The A•LOK®Connectors Between Reinforced Concrete Manhole Structures and Premium™ Connector as manufactured by A•LOK Products, Inc., Tullytown, PA orCorrugated High Density Polyethylene Drainage Pipes”. approved equal. The design of the connector shall provide a flexible, watertight seal between theExtruded from compounds formulated for wastewater applications, the pipe and concrete structure. The connector shall assure that a seal is maderubber connector is engineered to conform to the requirements of ASTM between:F-2510. Alternative compounds are available upon special request. 1. The connector and the structure wall by casting the connector integrally with the structure wall during the manufacturing process in a manner that it will notRESILIENT TEST REQUIREMENTS OF A.S.T.M. F-2510 pull out during pipe coupling. The connector shall also be capable of being cast into a round structure by curving the connector in a manner that allows it toTEST RESULTS remain centrally located within the structure wall and perpendicular to the pipe.Original Properties This configuration will result in no loss of seal or deflection of pipe entering aTensile strength, 1200 psi (8.3) concrete structure. 325 2. The seal between the connector and the pipe shall be made by the min, psi (MPa) 40 to 60 compression of the connector between the outside circumference of the factoryElongation 15 installed smooth oversleeve of a corrugated pipe or the smooth surface of a 25 traditional pipe and the interior hole opening of the structure. The connector shall min, % No cracks be the only component to affect the seal between the pipe and structure.Hardness No Fractures -40°F The connector shall be made from materials that conform to the physical and (-40°C) Section 4, “Materials and Manufacture” of ASTM F-2510 Standard Specification Type A durometer 200 (34) for Resilient Connectors Between Reinforced Concrete Manhole Structures andLow-temperature hardness, Corrugated High Density Polyethylene Drainage Pipes”, and the overall design will 15 meet or exceed Section 7, “Test Methods and Requirements” of ASTM F-2510. Type A durometer, max increase, points 20 This connector shall be sized specifically for the type of pipe being used and shallCompression set, max % 8 be installed in accordance with the recommendations of the manufacturer.Ozone resistanceLow Temperature Brittle Point 5 INSTALLATION INSTRUCTIONSTear Resistance STEP 1: lbf/in (kN/m), Die B Confirm that the pipe surface is smooth, clean and free of foreign materials, chips, gouges andAccelerated Aging (Air Oven Test): form seams due to manufacturing or handling.Decrease in tensile strength, Slightly bevel any sharp or blunt edges caused by the cutting of the pipe. max % of originalDecrease in elongation, STEP 2: Lubricate the connector and the entire section max % of original of the pipe that will be inserted into theHardness, Type A durometer, connector. The chart below lists A-LOK’s minimum lubrication length “L”. max increase, pointsAfter Water Immersion:Change in volume max %Copyright ASTM INTERNATIONAL. Reprinted with permissionDIMENSIONAL DATA PIPE SIZE MIN. LUBRICATION LENGTH “L” 8” - 15” 12” Maximum Pipe O.D. Based on Manhole 16” - 18” 18” Diameter and Pipe Angles Using 21” & Larger 24” A•LOK® Premium™ Connectors. STEP 3: Center the pipe and connector square to each other and insert the pipe into the connector using a bar or back hoe depending on the size. Once the pipe is coupled with the connector, deflect the structure or pipe to achieve the proper angle. MAX. PIPE SIZE OD’s WARNING To ensure the A-LOK® Premium™ Connector Manhole 135° - 225° 90° remains a flexible watertight connector, it is A- Diameter Pipe Angle Pipe Angle LOK Products, Inc. strong recommendation that no mortar be placed between the pipe and wall 42” 26.5” 22.0” of the concrete structure. The use of mortar in this 48” 31.5” 25.0” area would decrease the effectiveness of the 60” 42.0” 32.0” connector to compensate for shear caused by 72” 52.5” 38.0” settlement or ground movement. 84” 59.5” 44.0” 96” 73.5” 50.0” CAUTION: NOTE: 108” 76.0” 56.0” To find approximate subgrade, measure from the 120” 85.0” 62.0” When installing pipe stubs outside base of the structure to the junction of the for future pipeline installation, connector and flat spot. Then add the wall all stubs must be properly thickness of the pipe plus 1/4 inch. restrained to prevent anyMin. distance between pipes is movement by means otherapprox. 1/2 the smallest pipe OD than the A-LOK® Premium™Connector.© 2009 A-LOK Products, Inc. Supercedes all previous literature P.O. BOX 1647 • 697 MAIN STREET • TULLYTOWN, PA 19007• [email protected] BY ISSUED AND/OR PENDING PATENTS 800-822-2565 • 215-547-3366 • 215-547-5260 FAX • www.a-lok.com

The Company With Connections® TMPIPE TO STRUCTURE CONNECTOR FOR STORMWATER SYSTEMSA•LOK STM A•LOK STM PRODUCT REFERENCESThe A•LOK STM is a A.) ASTM C-1478flexible pipe-to-man- Standard Specification for Storm Drain Resilient Connectorshole connector Between Reinforced Concrete Storm Sewer Structures, Pipes,designed for the pre- and Laterals.vention of soil andwater infiltration into B.) ASTM C-1244stormwater sewer Standard Test Method For Concrete Sewer Manholessystems. It can be by the Negative Air Pressure (Vacuum) Testused with both roundand elliptical shaped C.) ASTM C-478pipes and curved and Standard Specification for Precast Reinforced Concreteflat wall structures. It Manhole Sectionsis available for 8\"diameter and larger PERFORMANCE STANDARDpipes. The A•LOK STM meets or exceeds all material and test requirements MATERIAL of ASTM C-1478: “Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm SewerThe standard connector is extruded from a polyisoprene compound Structures, Pipes, and Laterals”.engineered to conform with the requirements outlined in section4.1.1 of ASTM C-1478 “Standard Specification for Storm Drain See following chart:Resilient Connectors Between Reinforced Concrete Storm SewerStructures, Pipes, and Laterals”. Alternative compounds are avail- RESILIENT MATERIAL TEST OF ASTM C-1478able for unusual applications upon special order. TEST RESULTS ASTM METHOD KEY ADVANTAGES Chemical resistance D 543 no weight loss at 22°C for 48hThe A•LOK STM Connector functions on pure compression, making 1 N Sulfuric acid no weight lossfield installation quick and easy. Just clean and lubricate the connector 1 N Hydrochloric D 412and pipe, center the pipe in the connector, and insert. This rapid instal- Acid 1200 psi orlation permits immediate backfilling, enhancing project safety and over- Tensile strength 8.5 MPa, min D 2240comes the normal problems encountered with water, running sand and Elongation at break 350% min. (Shore Aother unstable trench conditions. This results in shorter job projections, Hardness ±5 from mfg’s. durometer)while mininizing traffic interruption and cost overruns. specified hardness D 573, Accelerated 70±1°C forThe A•LOK STM provides up to 10° of omnidirectional deflection while oven-aging decr. of 15%, 7 daysstill maintaining a watertight seal. This design allows the connector to max. of originalcompensate for shear due to settlement or ground movement preventing Compression set tensile strength, D 395, Method B,water and soil infiltration into the sewer system. This proper pipe-to- decr. of 20% at 70°C for 22hstructure connection minimizes the chance of pothole formation and Water absorption max. of elongation D 471, immersesediment build-up in the storm system, saving states and municipalities decr. of 25%, 0.75 by 2-in. ormoney over the life of the structure. max. of original 19 by 25-mm deflection Specimen inOn larger diameter pipe when size prohibits a gasket from being installed increase of 10%, distilled waterin a flat plane, an A•LOK STM Connector can be configured for casting max. of original at 70°C for 48hin a curve with the connector staying perpendicular to the center line of by weight D 1171the pipe. This design has resulted from years of extensive research and D 746development and causes no loss of compression or deflection. Ozone resistance rating 0 D 624, Method B Low-temp no fracture at brittle point -40°C Tear resistance 200 lbf/in. or 34 kn/m Copyright ASTM INTERNATIONAL. Reprinted with permission

PART 6 • DIMENSIONAL DATAA•LOK STM Cross Section / Pipe Size OD’s 93 Series 8.50\" - 29.00\" 94 Series MAX. PIPE SIZE OD’s MBAOXX. PSITPREUSCIZTUE ROEDS’s 30.00\" - 59.50\" Manhole 135° - 225° 90° Inside Wall Straight 90° 95 Series Diameter Pipe Angle Pipe Angle Dimension Through Pipe Angle 60.00\" - 87.50\" 19.50” 42” 26.5” 22.0” 2' 32.00” 17.50”Larger Sizes Available 48” 31.5” 25.0” 3' 44.00” 30.00”Upon Special Request 60” 42.0” 32.0” 4' 56.00” 42.00” 72” 52.5” 38.0” 5' 67.00” 54.00” 84” 59.5” 44.0” 6' 80.50” 65.00” 96” 73.5” 50.0” 7' 91.25” 78.50” 108” 76.0” 56.0” 8' 103.25” 89.25” 120” 85.0” 62.0” 9' 101.25”INSTALLATION INSTRUCTIONS PRODUCT SPECIFICATIONS STEP 1: A flexible pipe to manhole connector shall be used whenever a pipe Confirm that the pipe surface is smooth, clean penetrates into a precast concrete manhole or structure used in a stormwater and free of foreign materials, chips, gouges and drainage system. form seams due to manufacturing or handling. Slightly bevel any sharp or blunt edges caused by The connector shall be the A•LOK® STM CONNECTOR as manufactured by the cutting of the pipe. A•LOK PRODUCTS, INC., Tullytown, PA, or approved equal. STEP 2: The design of the connector shall provide a flexible, watertight seal between the pipe Lubricate the connector and the entire section and concrete structure. The connector shall assure that a seal is made between: of the pipe that will be inserted into the connec- tor. The chart below lists A-LOK’s minimum (1) The connector and the structure wall by casting the connector lubrication length “L”. integrally with the structure wall during the manufacturing process in a manner that it will not pull out during pipe coupling. The connector shall also be capable PIPE SIZE MIN. LUBRICATION LENGTH “L” of being cast into a round structure by curving the connector in a manner that 4” - 15” 12” allows it to remain centrally located within the structure wall and perpendicular 16” - 18” 18” to the pipe. This configuration will result in no loss of seal or deflection of pipe 21” & Larger 24” entering a concrete structure.CAUTION: STEP 3: (2) The seal between the connector and the pipe shall be made by the compres- Center the pipe and connector square to each other sion of the connector between the outside circumference of the pipe and the inte-When installing pipe and insert the pipe into the connector using a rior hole opening of the structure. The connector shall be the only component tostubs for future pipeline bar or back hoe depending on the size. Once affect the seal between the pipe and structure.installation, all stubs the pipe is coupled with the connector, deflect themust be properly structure or pipe to achieve the proper angle. The connector shall be made from materials that conform to the physical andrestrained to prevent any chemical requirements outlined in Section 4, “Materials and Manufacture” ofmovement by means WARNING ASTM C-1478 “Standard Specification for Storm Drain Resilient Connectorsother than the A-LOK To ensure the A-LOK STM Connector remains a Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals,” andSTM Connector. flexible watertight connector, it is A-LOK the overall design will meet or exceed Section 7, “Test Methods and Products, Inc. strong recommendation that no Requirements” of ASTM C-1478. mortar be placed between the pipe and wall of the concrete structure. The use of mortar in this The connector shall be sized specifically for the type of pipe being used and shall area would decrease the effectiveness of the con- be installed in accordance with the recommendations of the manufacturer. nector to compensate for shear caused by settle- ment or ground movement. ANY QUESTIONS REGARDING A•LOK STM CONNECTOR INSTALLATION, PLEASE CALL 1-800-822-2565 NOTE: To find approximate subgrade, measure from the outside base of the structure to the junction of the connector and flat spot. Then add the wall thick- ness of the pipe plus 1/4 inch.A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

The Company With Connections® TMINCOMPARABLE PIPE-TO-MANHOLE CONNECTORS FOR SANITARY SYSTEMSX-CEL A•LOK X-CEL KEY ADVANTAGES (continued)Designed to produce a On larger-diameter pipe, where size prohibits a gasket from beingguaranteed watertight installed in a flat plane, the X-CEL can be configured for casting in aseal between pipe and curve with the connector staying perpendicular to the center line of theconcrete, the A•LOK pipe. Discovered through years of extensive research and development,X-CEL flexible pipe-to- the configurations cause no loss of compression or deflection.manhole connectorprovides maximum Functioning on pure compression, the X-CEL allows for fast andperformance on the job easy field installation. After the connector and pipe are cleaned andsite. Its unique design lubricated, the pipe is simply centered in the connector and inserted.not only saves valuable Backfilling can be done immediately, thus enhancing project safety andproject time, but also overcoming the typical problems of water, running sand and otherensures longevity and unstable trench conditions.offers unsurpassedenvironmental benefits. For Specifiers, the X-CEL connector offers a guaranteed solution to the age-old containment system problem of the best way to connect pipesA•LOK X-CEL connectors prevent infiltration and ex-filtration into and concrete structures. Precasters using X-CEL connectors experiencewastewater or stormwater systems, and are installed in the precast increased satisfaction due to their ability to offer a complete watertight,structure in a way that does not require coring or placement after the guaranteed product, while municipalities that install X-CEL willbase component is cast. This eliminates residual waste from coring, ultimately spend less on road repair by avoiding the possibility of pot/sinkdisposal of the slugs or wasted raw material utilization or energy. holes that are often the result of leaking, non-connected, systems.Once cast-in, the connector becomes an integral component of thestructure wall. PRODUCT REFERENCESBased on the traditional A•LOK connector, the X-CEL's enhanced A.) ASTM C-923features improve performance. Take the patented “water pocket” for Resilient Connector Between Reinforced Concreteexample, which utilizes the untapped pressure of ground water to Manholes Structures, Pipe and Laterals.exert a clamping force around the connector and pipe, allowing theconnector to perform in deeper installations. B.) ASTM C-1244 Standard Test Method For Concrete Sewer ManholesDemonstrated in tests higher than 15 psi of hydrostatic water pres- by the Negative Air Pressure (Vacuum) Testsure, the X-CEL's unique design provides 45 percent more rubbercontact with the pipe, allowing for greater pipe deflection. C.) ASTM C-478 Standard Specification for Precast Reinforced Concrete MATERIAL Manhole SectionsMolded or extruded from compounds formulated for wastewater PERFORMANCE STANDARDapplications and engineered to conform to the requirements ofsection 4.1.1 of ASTM C-923, the standard rubber connector is available The A•LOK X-CEL guaranteed Connector meets or exceeds allin alternative compounds upon request. Contact an A•LOK representa- material and test requirements outlined in ASTM C-923: “Resilienttive regarding special applications, such as the presence of hydrocar- Connectors Between Reinforced Concrete Manhole Structures,bons. Pipes and Laterals.” KEY ADVANTAGES Molded or extruded from compounds formulated for wastewater applications, the standard rubber connector is engineered to confirmThe A•LOK X-CEL offers distinct advantages for engineers, specifiers, with the requirements of section 4.1.1 of ASTM C-923. Alternativeprecasters and municipalities. An enhanced profile gives the connector compounds are available upon special request.45% greater rubber contact with the pipe, thus allowing the pipe to bedeflected in excess of 10 degrees of omnidirectional deflection, all thewhile maintaining a watertight seal. These enhancements allow formore flexibility to compensate for pipe shear due to settlement orground movement.

PERFORMANCE STANDARD (continued) PRODUCT SPECIFICATIONSRESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923 A flexible pipe to manhole connector shall be used whenever a pipe penetrates into a precast concrete manhole or structure. The connector shall beTEST RESULTS ASTM METHOD the A•LOK X-CEL CONNECTOR as manufactured by A•LOK PRODUCTS, INC.,Chemical resistance at 22°C for 48h Tullytown, PA, or approved equal. no weight loss 1 N Sulfuric acid no weight loss D 412 The design of the connector shall provide a flexible, watertight seal between the pipe 1 N Hydrochloric and concrete structure. The connector shall assure that a seal is made between: Acid 1200 psi or D 2240Tensile strength 8.5 MPa, min (Shore A (1) The connector and the structure wall by casting the connectorElongation at break 350% min. durometer) integrally with the structure wall during the manufacturing process in a mannerHardness ±5 from mfg’s. D 573, that it will not pull out during pipe coupling. The connector shall also be capable specified hardness 70±1°C for of being cast into a round structure by curving the connector in a manner thatAccelerated 7 days allows it to remain centrally located within the structure wall and perpendicularoven-aging decr. of 15%, to the pipe. This configuration will result in no loss of seal or deflection of pipe max. of original D 395, Method B, entering a concrete structure.Compression set tensile strength, at 70°C for 22h decr. of 20% D 471, immerse (2) The seal between the connector and the pipe shall be made by the compres-Water absorption max. of elongation 0.75 by 2-in. or sion of the connector between the outside circumference of the pipe and the inte- decr. of 25%, 19 by 25-mm rior hole opening of the structure. The connector shall be the only component to max. of original Specimen in affect the seal between the pipe and structure. deflection distilled water increase of 10%, at 70°C for 48h The connector shall be made from materials that conform to the physical and max. of original D 1171 chemical requirements outlined in Section 4, “Materials and Manufacture” of by weight D 746 ASTM C-923 Standard Specification for Resilient Connectors between Reinforced D 624, Method B Concrete Manhole Structures, Pipes, and Laterals, and the overall design will meetOzone resistance rating 0 or exceed Section 7, “Test Methods and Requirements” of ASTM C-923.Low-temp no fracture atbrittle point -40°C The connector shall be sized specifically for the type of pipe being used and shallTear resistance 200 lbf/in. be installed in accordance with the recommendations of the manufacturer. or 34 kn/mCopyright ASTM INTERNATIONAL. Reprinted with permissionDIMENSIONAL DATA INSTALLATION INSTRUCTIONSA•LOK X-CEL Cross Sections / Pipe Size OD’s STEP 1: Confirm that the pipe surface is smooth, clean92 Molded Series and free of foreign materials, chips, gouges and 4.25” - 7.25” form seams due to manufacturing or handling. Slightly bevel any sharp or blunt edges caused by the cutting of the pipe. 94 Extruded Series STEP 2: 30.00” - 59.50” Lubricate the connector and the entire section of the pipe that will be inserted into the connec- 93 Molded Series tor. The chart below lists A-LOK’s minimum 8.50” - 13.00” lubrication length “L”.93 Extruded Series 95 Extruded Series PIPE SIZE MIN. LUBRICATION LENGTH “L” 13.25” - 29.00” 60.00” - 87.50” 4” - 15” 12” 16” - 18” 18” Larger Sizes Available 21” & Larger 24” Upon Special Request STEP 3: MAX. PIPE SIZE OD’s Center the pipe and connector square to each other and insert the pipe into the connector using a Manhole 135° - 225° 90° CAUTION: bar or back hoe depending on the size. Once Diameter Pipe Angle Pipe Angle the pipe is coupled with the connector, deflect the When installing pipe structure or pipe to achieve the proper angle. 42” 26.5” 22.0” stubs for future pipeline 48” 31.5” 25.0” installation, all stubs WARNING 60” 42.0” 32.0” must be properly To ensure the A-LOK X-CEL Connector remains 72” 52.5” 38.0” restrained to prevent any a flexible watertight connector, it is A-LOK 84” 59.5” 44.0” movement by means Products, Inc. strong recommendation that no 96” 73.5” 50.0” other than the A-LOK mortar be placed between the pipe and wall of 108” 76.0” 56.0” X-CEL Connector. the concrete structure. The use of mortar in this 120” 85.0” 62.0” area would decrease the effectiveness of the con- nector to compensate for shear caused by settle- ment or ground movement. NOTE: To find approximate subgrade, measure from the outside base of the structure to the junction of the connector and flat spot. Then add the wall thick- ness of the pipe plus 1/4 inch.A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

The Company With Connections®PIPE-TO-MANHOLE AND LATERAL CONNECTORSINSERTA•LOK™ A•LOK INSERTA•LOK™ PRODUCT REFERENCESThe INSERTA•LOK™ Pipe to A.) ASTM C-923Manhole Connector and Resilient Connector Between Reinforced ConcreteINSERTA•LOK MD Lateral Manholes Structures and Pipe.Connector are flexible connec-tors specifically engineered to B.) ASTM C-1244produce a positive watertight Standard Test Method For Concrete Sewer Manholesseal for pipes entering precast by the Negative Air Pressure (Vacuum) Testconcrete structures and thestructure itself. The C.) ASTM C-478CINSERTA•LOK Connectors are Standard Specification for Precast Reinforced Concretemanufactured to meet or exceed Manhole Sectionsthe requirements set forth inASTM C-923 titled “Resilient PERFORMANCE STANDARDConnector Between ReinforcedConcrete Structures and Pipe.” The INSERTA•LOK Connectors meets or exceeds all material and performance requirements of ASTM Standard C-923 titled “Resilient MATERIAL Connectors Between Reinforced Concrete Manhole Structures and Pipes.”The connector is extruded from a compound formulated for waste-water applications and engineered to conform with the Resilient PART 6 • DIMENSIONAL DATAMaterial Requirements of section 4.1.1. Alternative compounds areavailable for unusual applications upon special order. INSERTA•LOK™ FOR SANITARY MANHOLES ROUND AND FLATWALL KEY ADVANTAGES TYPE OF PIPE Nominal Inserta•LOK Inserta•LOK MDThe INSERTA•LOK Connectors function on pure compression making Pipe O.D. HOLE SIZE HOLE SIZEfield installation quick and easy. Clean and lubricate both connector 4” P VC SDR 35and pipe, center pipe in connector, and insert. 4” PVC SDR 40 4.25” — 5.00” 4” DUCTILE 4.50”The connector provides a tapered profile which enhances coupling 6” PVC SDR 35 4.75” — 5.25”characteristics by allowing final compression to be gradual, thereby 6” DUCTILE 6.25”reducing the overall coupling force. 8” PVC SDR 35 6.875” — 5.50” 8” DUCTILE 8.50”The INSERTA•LOK Connectors can be installed in a precision cast or 10” PVC SDR 35 9.00” — 7.00”cored opening as a mainline connector for new construction, a retro- 10” DUCTILE 10.50”fit or a tie in for new construction. 12” PVC SDR 35 11.25” — 7.625” 12” DUCTILE 12.50”The connector assures a positive watertight connection providing over 13.00” 10.00” 9.25”7 degrees of omnidirectional deflection to eliminate infiltration andshear due to settlement or ground movement. This flexibility permits 10.50” 9.75”immediate backfill enhancing project safety, and overcoming theproblems normally encountered with water, running sand and other 12.00” 11.50”unstable trench conditions. 12.50” 12.00” 14.00” 13.25” 14.50” 13.75” FOR LATERAL CONNECTORS YOU MUST USE MD INSERTA•LOK WITH 2 STAGE CORE BIT

PERFORMANCE STANDARD PRODUCT SPECIFICATIONSRESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923 A flexible pipe to manhole connector shall be used for sanitary and drain pipe penetrations into precast concrete manholes and struc-TEST RESULTS ASTM METHOD tures.Chemical resistance at 22°C for 48h The connector shall be the INSERTA•LOK™ CONNECTOR as man- no weight loss ufactured by A•LOK PRODUCTS, INC., Tullytown, PA, or approved 1 N Sulfuric acid no weight loss D 412 equal. 1 N Hydrochloric The design of the seal shall provide a flexible, positive watertight con- Acid 1200 psi or D 2240 nection between the pipe and concrete wastewater structures. TheTensile strength 8.5 MPa, min (Shore A connector shall assure that a seal is made between (1) the connec-Elongation at break 350% min. durometer) tor and the structure wall, and (2) between the connector and theHardness ±5 from mfg’s. D 573, pipe. The seal between the connector and the structure wall will be specified hardness 70±1°C for made by pure compression of the resilient material against the wallAccelerated 7 days of the structure. The seal between the connector and the pipe will beoven-aging decr. of 15%, made by pure compression of the resilient material against the out- max. of original D 395, Method B, side diameter of the pipe. The connector shall be the only componentCompression set tensile strength, at 70°C for 22h to affect the seal between the pipe and structure. decr. of 20% D 471, immerse The connector shall be extruded and vulcanized from materialsWater absorption max. of elongation 0.75 by 2-in. or whose physical/chemical properties meet or exceed the decr. of 25%, 19 by 25-mm physical/chemical resistant properties outlined in ASTM C-923.Ozone resistance max. of original Specimen in The connector shall be of size specifically designed for the pipe mate-Low-temperature deflection distilled water rial being used and shall be installed in accordance with the recom-brittle point increase of 10%, at 70°C for 48h mendations of the manufacturer.Tear resistance max. of original D 1171 by weight D 746 INSTALLATION OF PIPE INTO CONNECTOR D 624, Method B rating 0 no fracture at -40°C 200 lbf/in. or 34 kn/mINSTALLATION INSTRUCTIONSINSTALLATION OF CONNECTOR INTO WALL IMPORTANT: BEVEL AND LUBRICATE PIPE ALSO CENTER PIPE BEFORE PUSHING PIPE HOME LUBRICATE INSIDE OF INSERTA•LOK CONNECTORWARNING: To ensure the INSERTA•LOK™ Connector remains a flexible, watertight joint, it is A•LOK Products, Inc. strong recom-mendation that no mortar be placed between the pipe and wall of the precast concrete unit. The use of mortar in this area wouldeliminate the flexibility for which the connector was designed and cause problems of shear.NOTE: Approximate subgrade of trench at the structure can be determined by measuring from the bottom of the connector or flatspot if present, tot he bottom of the manhole and wall thickness of pipe.CAUTION: When installing pipe stubs for future pipeline, installation of all stubs should be properly restrained to prevent any move-ment by means other than, and in addition to, the resilient connector.ANY QUESTIONS REGARDING A•LOK INSERTA•LOK INSTALLATION, PLEASE CALL 1-800-822-2565 A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

The Company With Connections®SPECIALLY DESIGNED MANDREL AND MAGNETIC HOLDERMAGNETIC MANDREL SYSTEMA•LOK MAGNETIC MANDREL SYSTEM KEY ADVANTAGES • Faster set-up • No drilling or cutting of core • Special curved magnet face to maximize form contact • Magnet possesses great magnetic strength, high residual magnetism, strong coercive force and good stability • Mandrels offer excellent chemical and abrasion resistance • Available for inside or outside mount • Compatible with wet and dry applications WARNING • DO NOT SUBJECT MAGNETS TO BLUNT FORCE IMPACT. • PROLONGED TEMPERATURES ABOVE 160°F WILL CAUSE LOSS OF MAGNETIC ENERGY. • DO NOT WELD NEAR MAGNETS. • AVOID HIGH ELECTRICAL CURRENTS NEAR MAGNETS.A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX







Introducing A-LOK’s Newest Product Exclusively Distributed by P.O. Box 1647 Tullytown, PA 19007 800-822-2565 215-547-5260 (fax)GrandSlam™ Lubricant is a new material specifically formulated for pipe penetrationsinto all A-LOK connectors as well as joining all types of pipes in trenches and manholes.• Very Slippery! GrandSlam™ Lubricant reduces friction of the gasket against the bell and the pipe against the connector. It helps pipe slide in smoothly minimizing the possibility of the gasket to displace and cause bell damage or the beveled pipe to tear the connector.• Special Wax Technology! GrandSlam™ contains a special wax that fills in the microscopic pores in concrete. By filling in the pores, gaskets slide rather than catch on the concrete surface.• Clean and Neat to Use! GrandSlam™ Lubricant washes off hands, tools and clothing with soap and water. It has no bad smell and does not get soupy, so field crews are more willing to apply it properly ensuring good field performance.• Easy to Apply! GrandSlam™ Lubricant clings to everything! Gaskets, connectors, concrete, PVC, ductile iron, HDPE, clay, and steel surfaces. It’s unique formulation keeps the lubricant where it belongs whether applied by hand, swab or brush. A totally lubricated area minimizes the threat of damage during installations.• Compatible! GrandSlam™ Lubricant does not affect or swell rubber or plastic gaskets. It contains no hydrocarbon or silicone greases. It does not affect gaskets over time to cause eventual leakage or breakage.• Safe and Non Toxic! Harmless to people and the environment when used as directed. Can be safely used in the field. Suitable for potable water systems. Meets NSF/ANSI Standard 61.“By preventing even one damaged pipe per month, GrandSlam™ Lubricant can pay for itselfover and over again! “GrandSlam™ Summer Grade GrandSlam™ Winter Package Size Grade GSQ-128 1 gal. pail (4/cs) GWQ-128GSQ-448 GWQ-448 3.5 gal. pail (1 ea)GSQ-640 GWQ-640 5 gal. pail (1 ea)

Application & Installation1. GrandSlam™ Lubricant is ready to use in the pail. Do not dilute, thin, or otherwise alter its consistency. For best results lubricate surfaces right before making connections.2. Clean all surfaces before applying lube. Outside the pipe and all over the connector for pipe penetrations. Inside the bell outside the spigot for pipe to pipe.3. For pipe penetrations into a connector, bevel the pipe, lubricate the connector all around, then lubricate the pipe back ½ its diameter up to 21”.4. The lubricant can be brushed on, swabbed on, or wiped on by hand with a cloth glove. Be sure to get full lubricant coverage. Don’t leave any area “DRY.” GrandSlam™ Lubricant makes such applications easy by grabbing and clinging to all surfaces.5. Because GrandSlam ™ lubricant will adhere when applied under water, steps 1-6 can be done in the rain or in a wet trench just like an A-LOK pipe installation.6. After lubrication, a pipe can be centered and inserted into a connector or pipes can be aligned and joined by an approved coupling method.7. For pipe to pipe installations position the gasket in the groove and equalize its stretch by lifting it slightly with a screwdriver while completely circling the pipe. Apply lubrication on top of the newly inserted gasket using one of the methods in step 4.Specifications:Lubricant Description Gasket High- Coating Adhesion to Freezing Compatibility Temperature Properties Wet PointGrandSlam™ High solids Separation ConcreteSummer with wetting <1.0% Wt. Spreads 32°FGrade agents; water- Gain Retains smoothly and Spreads based paste <1 Duro Pts. thickness and evenly smoothly andGrandSlam™ appearances No washout evenlyWinter Grade High solids <1.0% Wt. at high No washout with wetting Gain temperatures Spreads agents; water- <1 Duro Pts. Retains smoothly and Spreads 10ºF based paste thickness and evenly smoothly and appearances No washout evenly at high No washout temperaturesCopyright 2003. American Polywater Corporation. All Rights ReservedImportant Notice: The statements here are made in good faith based on tests and observations we believe to be [email protected] (e-mail) P.O. Box 53reliable. However, the completeness and accuracy of the information is not guaranteed. Before using, the end- http://www.polywater.com(URL) Stillwater, MN 55082user should conduct whatever evaluations are necessary to determine that the product is suitable for the intendeduse. U.S.AAmerican Polywater expressly disclaims any implied warranties and conditions of merchantability and fitness for a 1-800-328-9384particular purpose. American Polywater's only obligation shall be to replace such quantity of the product proven to 1-651-430-2270be defective. Except for the replacement remedy, American Polywater shall not be liable for any loss, injury, or fax 1-651-430-363direct, indirect, or consequential damages resulting from product’s use, regardless of the legal theory asserted.LIT-GSQFLYER/11-09/INTERNAL

The Company With Connections® TMPIPE TO CONCRETE STRUCTURE COLD JOINT CONNECTORWATER-STOP For all Corrugated or Smooth Wall Pipes WATER-STOP CONNECTORS PERFORMANCE STANDARDWATER-STOP WATER-STOP passes ASTM C-1244 Vacuum Test and meets andConnectors easily exceeds all material and test requirements of ASTM 1478 and ASTMinstall to the outside C-923 Resilient Materials Test, Section 4: “Resilient Connectorsdiameter of corrugated Between Reinforced Concrete Manhole Structures, Pipes andor smooth wall pipe. Laterals”.Designed for use withnew or existing round See following chart:or flat wall structures RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923to seal cold joint pipepenetrations. TEST RESULTS ASTM METHOD Chemical resistance at 22°C for 48hMATERIAL (Fig. 1) Tightening down one piece spliced no weight loss WATER-STOP with torque wrench prior to 1 N Sulfuric acid no weight loss D 412 grouting. 1 N Hydrochloric Acid 1200 psi or D 2240WATER-STOP is extruded from an Polyisoprene/SBR blend Tensile strength 8.5 MPa, min (Shore Acompound engineered to conform with the requirements of Section Elongation at break 350% min. durometer)4.1.1 of ASTM C-923. Alternative compounds are available for Hardness ±5 from mfg’s. D 573,unusual applications upon special order. specified hardness 70±1°C forAll stainless steel hardware is in compliance with Section 4.2, Accelerated 7 days“Mechanical Devices” of ASTM C-923. oven-aging decr. of 15%, max. of original D 395, Method B, KEY ADVANTAGES Compression set tensile strength, at 70°C for 22h decr. of 20% D 471, immerseThe WATER-STOP profile provides a better surface than PVC or Water absorption max. of elongation 0.75 by 2-in. orcorrugated HDPE for grout to adhere as well as a watertight connection decr. of 25%, 19 by 25-mmbetween the connector and pipe. The “Special T” profile also helps Ozone resistance max. of original Specimen inprevent water and soil infiltration for all types of pipe. This connector is Low-temp deflection distilled watermade from a Polyisoprene SBR blend. The WATER-STOP Wedge Kit brittle point increase of 10%, at 70°C for 48h(see Fig. 2) can easily be installed around existing pipes during the Tear resistance max. of original D 1171rehabilitation process. by weight D 746The one piece spliced WATER-STOP (see Fig. 1) is normally installed D 624, Method Bover the end of new pipe installations such as field poured structures, rating 0mortared connections to precast structures, casting pipe hubs into no fracture atconcrete structures and doghouse field poured collars. -40°C 200 lbf/in. or 34 kn/m Copyright ASTM INTERNATIONAL. Reprinted with permission DIMENSIONAL DATAPRODUCT REFERENCES Plus or minus 1\" of the nominal pipe O.D. When ordering for corrugated pipe, it is important to specify the pipe manufacturer and the O.D. of theA.) ASTM C-923 crest of the corrugation, if possible, for proper fit.Resilient Connector Between Reinforced Concrete Up to 18\" corrugated uses single clamp as does all sizes of smooth wallManholes Structures, Pipe and Laterals. pipe. 24\" corrugated pipe and above uses double clamp connector design.B.) ASTM C-1244Standard Test Method For Concrete Sewer Manholesby the Negative Air Pressure (Vacuum) TestC.) ASTM 1478 Double clamp WATER-STOP profile Single clamp WATER-STOP profileResilient Connectors Between Reinforced Concrete for corrugated over 18\" diameter. for all smooth wall and less thanStorm Sewer Structures, Pipes and Laterals. 18\" diameter corrugated pipe.

WEDGE STYLE WATER-STOP KIT (Fig. 2) COMPONENTS: Connector to fit Pipe O.D. Tube of GlueINSTALLATION INSTRUCTIONS (Existing Pipe) 1 Rubber Wedge 2 Steel Alignment PinsSTEP 1 STEP 2 STEP 3Insert pins in wedge and apply glue to both Wrap WATER-STOP around pipe. Install pins Torque down take down clamp to 60\" pounds tosides of wedge. and wedge to WATER-STOP. squeeze wedge with glue together. Once glue is set grouting can begin.ONE PIECE SPLICED STYLE WATER-STOPINSTALLATION INSTRUCTIONS (New Pipe)CORRUGATED PIPE FOR SIZES 18\" AND ABOVE1. Cast or core an opening in the structure 5\" 12 larger than the O.D. of the pipe. 32. Center one piece Water-Stop CPP over the 3 crest of pipe corrugation. 4 443. Position the take down clamp(s) in grooves of Water-Stop CPP. Then torque clamp(s) to 60 in.- lbs. with Torque wrench.4. Align pipe and connector in center of structure opening and mortar completely around annular space with non-shrink grout.5. If pouring in place, vibrate properly to insure complete compaction around seal. NOTE: Up to 15\" use a single clamp connector design and 18\" and above use double clamp connector design. NOTE: The 60 in.-lb. Torque Wrench is available through A•LOK Products, Inc. ANY QUESTIONS REGARDING WATER-STOP CONNECTOR, PLEASE CALL 1-800-822-2565A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX 7/07





The Company With Connections®PIPE TO MANHOLE CONNECTOR FOR SANITARY OR STORMWATER SYSTEMSG3 BOOT SYSTEMA•LOK G3 BOOT SYSTEM KEY ADVANTAGESThe Revolutionary The G3 Boot System can withstand 15° of omnidirectional deflection and ½” of centerline offset while still maintaining aG3 Band makes watertight connection. This flexibility eliminates infiltration due to pipe shear caused by settlement or ground movement.installation into a The inner O-ring design of the G3 Connector eliminates rubberstructure simple wrinkling, compensates for pipe irregularity and wall thickness to insure a watertight seal.and fast. Just install G3 Component Packaging, featuring a tough loop lock fastenerthe connector that keeps installation instructions, take down clamp, boot and band secure together from factory to job site.perpendicular to the PRODUCT SPECIFICATIONShole and tighten the A flexible pipe to manhole connector shall be used whenever a pipestainless steel nut. As penetrates into a precast concrete manhole or structure.the nut is tightened, a The connector shall be the G3 Boot System featuring component packaging as manufactured by A•LOK PRODUCTS, INC.,compressive force is Tullytown, PA, or approved equal.applied to the G3 The design of the connector shall provide a flexible, watertight seal between the pipe and concrete structure. The connector shallband ends, causing assure that a seal is made between (1) the connector and the structure wall by placing the connector and expansion band intothem to slide past the center third of the concrete hole opening. The band is then expanded by tightening the expansion mechanism increasing theeach other into bands overall circumference and compressing the connector against the sides of the hole opening. (2) The seal between thestraight alignment. G3 BOOT SYSTEM connector and the pipe shall be made by compressing the connector against the outside circumference of the pipe by meansThis movement WITH of a stainless steel take-down band.increases the bands COMPONENT PACKAGINGoverall circumference AND TORQUE WRENCHESand compresses theconnector against theopening in the structure wall, creating a watertight seal. To insurethe best seal, place the bolt in the 12 o’clock position of the holeopening and tighten the nut to the specified torque value. MATERIAL PART 6 • DIMENSIONAL DATAThe connector shall be made from materials that conforms to the G3 BOOT SIZE LISTphysical and chemical requirements outlined in Section 4, “Materialsand Manufacture” of ASTM C-923 “Standard Specification for PIPE O.D.Resilient Connectors Between Reinforced Concrete ManholeStructures, Pipes, and Laterals”, and the overall design will meet orexceed Section 7, “Test Methods and Requirements” of ASTM C-923.The connector shall be sized specifically for the type of pipe beingused and shall be installed in accordance with the recommendationsof the manufacturer. ITEM RANGE HOLE Min.-Max. SIZE G3-0804 3.50”-4.50” 8” G3-1206 6.0”-6.875” 12” PRODUCT REFERENCES G3-1208 8.0”-9.5” 12”G3 Boot System meets or exceeds requirements of ASTM C-923 G3-1410 10.0”-11.25” 14” G3-1612 12.0”-13.5” 16”

PERFORMANCE STANDARD INSTALLATION INSTRUCTIONS ASTM C-923 Section 4.1 1) Position G3- RESILIENT MATERIALS TESTS 1208 Boot & Band in hole,TEST RESULTS ASTM METHOD then tighten toChemical resistance no weight loss D 543, 25 ft-lbs using no weight loss at 22°C for 48h torque wrench. 1 N Sulfuric acid 1 N Hydrochloric 2) Insert pipe into rolled in acid connector. For inside mount,Tensile strength 1200 psi, min. D 412 affix clampElongation at break 350% min. behind O-ring. Torque to 60HardnessB ±5 from mfg’s. D 2240 in-lbs and specified hardness (Shore A durometer) backfill.Accelerated decr. of 15%, D 573, 3) For outsideoven-aging max. of original 70±1°C for mount: pull pipeCompression set tensile strength, 7 days back, reposition decr. of 20% D 395, Method B, pipe within the max. of elongation at 70°C for 22h wall and affix decr. of 25%, clamp directly max. of original behind O-ring. deflection Torque to 60 in- lbs and backfill.Water absorption increase of 10%, D 471, immerse max. of original 0.75 by 2-in. or by weight 19 by 25-mm Specimen in distilled water at 70°C for 48hOzone resistance rating 0 D 1171Low-temperature no fracture at D 746brittle point -40°CTear resistance 200 lbf/in. D 624, Die BCopyright ASTM INTERNATIONAL. Reprinted with permissionWARNING: To ensure the G3 Boot System remains a flexible watertight connector, itis A•LOK Products, Inc. strong recommendation that no mortar be placed betweenthe pipe and wall of the concrete structure. The use of mortar in this area woulddecrease the effectiveness of the connector to compensate for shear caused bysettlement or ground movement.NOTE: A•LOK strongly suggests use of proper torque wrenches to secure the G3Boot in the structure as well as to secure the takedown clamp around theconnector and pipe. Both torque wrenches are available through A•LOK Products,Inc.CAUTION: When installing pipe stubs for future pipeline installation, all stubs mustbe properly restrained to prevent any movement by means other than the G3Connector.ANY QUESTIONS REGARDING G3 BOOT SYSTEM, PLEASE CALL 1-800-822-2565 A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

The Company With Connections® TMPIPE TO MANHOLE CONNECTOR FOR SANITARY SYSTEMSZ•LOK CAST IN BOOT CONNECTOR Z•LOK PIPE TO MANHOLE CONNECTOR PRODUCT REFERENCESThe Z•LOK Pipe to A.) ASTM C-923Manhole Connector is Resilient Connector Between Reinforced Concretea flexible connector Manholes Structures, Pipe and Laterals.specifically engineeredto produce a positive B.) ASTM C-1244watertight seal for Standard Test Method For Concrete Sewer Manholespipes entering precast by the Negative Air Pressure (Vacuum) Testconcrete structures andthe structure itself. C.) ASTM C-478Its heavier wall is Standard Specification for Precast Reinforced Concretedesigned to provide the Manhole Sectionshighest performance.The Z•LOK PERFORMANCE STANDARDCONNECTOR ismanufactured to meet The Z•LOK Connector meets or exceeds all material and testor exceed the requirements of ASTM C-923: “Resilient Connectors Betweenrequirements set forth Reinforced Concrete Manhole Structures, Pipes and Laterals”.in ASTM C-923 titled“Resilient Connectors See following chart:Between ReinforcedConcrete Manhole RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923Structures, Pipes, andLaterals”. TEST RESULTS ASTM METHOD Chemical resistance at 22°C for 48h MATERIAL no weight loss 1 N Sulfuric acid no weight loss D 412The Z•LOK CONNECTOR is molded from an EPDM compound 1 N Hydrochloricengineered to conform with the requirements of section 4.1.1 of Acid 1200 psi or D 2240ASTM C-923. Alternative compounds are available for unusual Tensile strength 8.5 MPa, min (Shore Aapplications upon special order. Elongation at break 350% min. durometer) Hardness ±5 from mfg’s. D 573,All stainless steel hardware is in compliance with section 4.2, specified hardness 70±1°C for“Mechanical Devices” of ASTM C-923. Accelerated 7 days oven-aging decr. of 15%, KEY ADVANTAGES max. of original D 395, Method B, Compression set tensile strength, at 70°C for 22hThe Z•LOK CONNECTOR assures a positive watertight connection and decr. of 20% D 471, immerseprovides up to 25° of omnidirectional deflection and 1.50\" of vertical or Water absorption max. of elongation 0.75 by 2-in. orhorizontal movement without loss of seal, providing greater flexibility in decr. of 25%, 19 by 25-mmthe design and installation of pipelines and structures. These design Ozone resistance max. of original Specimen infeatures of the Z•LOK CONNECTOR prevent infiltration due to shear Low-temp deflection distilled watercaused by settlement or ground movement. brittle point increase of 10%, at 70°C for 48h Tear resistance max. of original D 1171The inner rubber O-ring design eliminates rubber wrinkling, by weight D 746compensates for pipe irregularity and wall thickness insuring a D 624, Method Bwatertight seal. rating 0 no fracture atThe unique bi-directional design, permits the Z•LOK CONNECTOR -40°Ctake-down clamp to be fastened from either the inside or outside of the 200 lbf/in.structure. Once fastened, immediate backfilling is possible enhancing or 34 kn/mproject safety and overcomes the normal problems encountered withwater, running sand and other unstable trench conditions. Copyright ASTM INTERNATIONAL. Reprinted with permissionWhen casting the Z•LOK CONNECTOR into the structure, making it anintegral part of the wall, 50% of the opportunity for infiltration iseliminated.

PART 6 • DIMENSIONAL DATA PRODUCT SPECIFICATIONS Z-LOK PIPE O.D. INCHES CLAMP A flexible pipe to manhole connector shall be used whenever a pipeRING NO. MIN. MAX. NUMBER penetrates into a precast concrete manhole or structure. C107-1 1.25” 1.75” CL-040 The connector shall be the Z•LOK CONNECTOR as manufactured by A•LOK C107-2 2.00” 2.50” CL-040 PRODUCTS, INC., Tullytown, PA, or approved equal. C107-3 2.75” 3.75” CL-088 C107-4 4.25” 6.25” CL-088 The design of the connector shall provide a flexible, watertight seal between the pipe C107-6 6.25” 8.25” CL-128 and concrete structure. The connector shall assure that a seal is made between: F208-8 8.25” 9.10” CL-188 C107-8 8.25” 10.25” CL-188 (1) The connector and the structure wall by casting the connector C107-10 10.25” 12.25” CL-188 integrally with the structure wall during the manufacturing process in a manner C107-12 12.25” 14.25” CL-248 that it will not pull out during pipe coupling. C107-15 14.25” 16.00” CL-EV15-18-L C107-16 16.25” 18.00” CL-EV15-18-L (2) The seal between the connector and the pipe shall be made by compressing C107-18 18.25\" 21.25\" CL-EV15-18-L the connector against the outside circumference of the pipe by means of a stainless steel take-down band.NOTE:• F208-8 GASKET CAN BE USED ON C107-6 MANDREL The connector shall be made from materials that conform to the physical and• WHEN ORDERING CLAMPS, PIPE OD’S ARE REQUIRED chemical requirements outlined in Section 4, “Materials and Manufacture” of• C107-1 AND C107-2 USE THE SAME MANDREL ASTM C-923 “Standard Specification for Resilient Connectors Between• C107-16 AND C107-18 USE THE SAME MANDREL Reinforced Concrete Manhole Structures, Pipes, and Laterals”, and the overall• REDI-LOK CLAMP IS REQUIRED FOR C107-15 design will meet or exceed Section 7, “Test Methods and Requirements” of ASTM C-923. THROUGH C107-18 GASKETS The connector shall be sized specifically for the type of pipe being used and shall 60 IN. LBS. be installed in accordance with the recommendations of the manufacturer. TORQUE WRENCH INSTALLATION INSTRUCTIONSINSIDE Z-LOK CONNECTOR – INWARD POSITIONOF STEP 1:MANHOLE Bevel pipe.DO NOT Clean connector.MORTAR Clean pipe ofTOP HALF dirt & debris.OF PIPELINE OUTSIDE OF MANHOLE DO NOT MORTAR INSIDE Z-LOK CONNECTOR INSTALLATION STEP 2: Center pipe in connector and push through.WARNING: To ensure the Z-LOK Connector remains a flexible STEP 3:watertight connector, it is A•LOK Products, Inc. strong Attach proper size clamprecommendation that no mortar be placed between the pipe and beside o-ring then centerwall of the concrete structure. The use of mortar in this area would pipe in connector and VERYdecrease the effectiveness of the connector to compensate for IMPORTANT tighten clampshear caused by settlement or ground movement. with torque wrench to 60 inch pounds.NOTE: The 60 in.-lb. Torque Wrench is available through A•LOKProducts, Inc. OUTSIDE INSTALLATION STEP 4: When installing a Z-LOKCAUTION: When installing pipe stubs for future pipeline installation, connector in the outside theall stubs must be properly restrained to prevent any movement by manhole position pull pipemeans other than the Z-LOK Connector. back out after inserting so the connector flips outward, ANY QUESTIONS REGARDING Z-LOK CONNECTOR, then VERY IMPORTANT - PLEASE CALL 1-800-822-2565 center pipe in connector and tighten the take down clamp to 60 inch pounds with a torque wrench.A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX 8/06



The Company With Connections® TMA BOOT STYLE CONNECTOR FOR SANITARY OR STORMWATER SYSTEMSZ•LOK STM Z•LOK STM PRODUCT REFERENCESThe Z•LOK STM CONNECTOR was designed by A-LOK Products, A.) ASTM C-923Inc. to address the need for a boot style connector for large diameter Resilient Connector Between Reinforced Concretepipe. This makes it ideally suited for sanitary applications, using Manholes Structures, Pipe and Laterals.smooth wall pipe or corrugated pipe with a factory installed smoothover sleeve and stormwater applications, with corrugated or smooth B.) ASTM C-1478wall pipe. Available for 6\"-102\" pipes. Resilient Connectors Between Reinforced Concrete Storm Sewers Structures, Pipes and Laterals.The Z•LOK STM Pipe toManhole Connector is a C.) ASTM C-1244flexible connector Standard Test Method For Concrete Sewer Manholesspecifically engineered to by the Negative Air Pressure (Vacuum) Test.produce a positivewatertight seal for pipes PERFORMANCE STANDARDentering precast concretestructures and the The Z•LOK STM Connector meets or exceeds all material and teststructure itself. requirements of ASTM C-923-00: “Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes and Laterals”. Z•LOK STM Connector cast into storm structure. See following chart: MATERIAL RESILIENT TEST REQUIREMENTS OF A.S.T.M. C-923The Z•LOK STM CONNECTOR is molded from a polyisoprene TEST RESULTS ASTM METHODcompound engineered to conform with the requirements of section Chemical resistance at 22°C for 48h4.1.1 of ASTM C-923. Alternative compounds are available for no weight lossunusual applications upon special order. 1 N Sulfuric acid no weight loss D 412All stainless steel hardware is in compliance with section 4.2, 1 N Hydrochloric“Mechanical Devices” of ASTM C-923. Acid 1200 psi or D 2240 Tensile strength 8.5 MPa, min (Shore A KEY ADVANTAGES Elongation at break 350% min. durometer) Hardness ±5 from mfg’s. D 573,The Z•LOK STM CONNECTOR assures a positive watertight specified hardness 70±1°C forconnection and provides up to 15° of omnidirectional deflection and Accelerated 7 days1.50\" of vertical or horizontal movement without loss of seal, oven-aging decr. of 15%,providing greater flexibility in the design and installation of pipelines max. of original D 395, Method B,and structures. These design features of the Z•LOK STM Compression set tensile strength, at 70°C for 22hCONNECTOR prevent infiltration due to shear caused by settlement decr. of 20% D 471, immerseor ground movement. Water absorption max. of elongation 0.75 by 2-in. orOnce fastened, immediate backfilling is possible enhancing project decr. of 25%, 19 by 25-mmsafety and overcomes the normal problems encountered with water, Ozone resistance max. of original Specimen inrunning sand and other unstable trench conditions. Low-temp deflection distilled waterWhen casting the Z•LOK STM CONNECTOR into the structure, brittle point increase of 10%, at 70°C for 48hmaking it an integral part of the wall, 50% of the opportunity for Tear resistance max. of original D 1171infiltration is eliminated. by weight D 746 D 624, Method B rating 0 no fracture at -40°C 200 lbf/in. or 34 kn/m Copyright ASTM INTERNATIONAL. Reprinted with permission A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

PRODUCT SPECIFICATIONS PRECAST INSTALLATION INSTRUCTIONSA flexible pipe to manhole connector shall be used whenever a pipe ONE-PIECE WEDGE KNOCKOUTpenetrates into a precast concrete manhole or structure. For 6\" FlatwallThe connector shall be the Z•LOK STM CONNECTOR as manufactured byA•LOK PRODUCTS, INC., Tullytown, PA, or approved equal. Pull connector over one-The design of the connector shall provide a flexible, watertight seal between the pipe piece Wedge Knockoutand concrete structure. The connector shall assure that a seal is made between: Hole Former as shown.(1) The connector and the structure wall by casting the connectorintegrally with the structure wall during the manufacturing process in a manner TWO-PIECE MANDRELthat it will not pull out during pipe coupling. For 8\" Flatwall and above(2) The seal between the connector and the pipe shall be made by compressingthe connector against the outside circumference of the smooth wall pipe or 1. Stretch gasket over outside mandrel half, withagainst the inside walls of the valley of the corrugated pipe by means of a cut-outs positioned at 3 and 9 o’clock.stainless steel take-down clamp.The connector shall be made from materials that conform to the physical and 2. Force gasket down inside mandrel beforechemical requirements outlined in Section 4, “Materials and Manufacture” of installing in form.ASTM C-923 “Standard Specification for Resilient Connectors BetweenReinforced Concrete Manhole Structures, Pipes, and Laterals”, and the overall 3. Use coil nut to tighten gasket and mandrelsdesign will meet or exceed Section 7, “Test Methods and Requirements” of ASTM together.C-923, using smooth wall pipe or corrugated pipe with a factory installed smooth TWO-PIECE MANDRELover sleeve, and ASTM C-1478 with smooth wall pipe or corrugated pipe. For Round ManholesThe connector shall be sized specifically for the type of pipe being used and shallbe installed in accordance with the recommendations of the manufacturer. FIELD INSTALLATION INSTRUCTIONS FIELD INSTALLATION INSTRUCTIONS SMOOTH WALL PIPE CORRUGATED PIPE FIELD INSTALLATION STEP 1: FIELD INSTALLATION Z•LOK STM Connector cast into storm structure. STEP 1: Z•LOK STM Connector cast into storm STEP 2: structure. Pipe is inserted and centered within the connector to obtain proper mechanicalSTEP 2: seal.Pipe is centered through theconnector. The Stainless Steel Clamp STEP 3:is centered above the valley of pipe Stainless Steel Clamp is tightenedmaking sure the fastening points are equally about the take-up point to 60positioned in the two cutout areas of in./lbs, insuring a watertight connection.the rubber connector. This should be done prior to any pipeSTEP 3: deflection or backfilling.Stainless Steel Clamp is tightened SECTION VIEWequally about the take-up point to 60in./lbs. This action compresses the WITH PIPErubber against the side walls of the INSTALLEDpipe valley and a watertightconnection is formed.IMPORTANT: After groove of SECTION VIEWpipe is centered in gasket WITH PIPE INSTALLEDtighten stainless steel clampequally to 60 in. lbs. with anA•LOK Torque Wrench.

DIMENSIONAL DATA Z-LOK STM CONNECTORS SMOOTH WALL PIPE DATA ANY QUESTIONS REGARDING Z•LOK STM CONNECTOR INSTALLATION, PLEASE CALL 1-800-822-2565

DIMENSIONAL DATA Z-LOK STM CONNECTORS CORRUGATED PIPE DATA COMPONENT IDENTIFICATION Smooth Wall Pipe FOR Z-LOK STM CONNECTORS MANHOLE MAX.Z-LOK STM PROFILE COMPARISION DIA. O.D. PIPE 48\" DIA. 28 IN. 5\" WALL 30 IN. 60\" DIA. 37 IN. 6\" WALL 44 IN. 72\" DIA. 51 IN. 7\" WALL 84\" DIA. 8\" WALL 96\" DIA. 9\" WALL Corrugated Pipe MANHOLE MAX. DIA. O.D. PIPE 48\" DIA. 22 IN. 5\" WALL 30 IN. 60\" DIA. 37 IN. 6\" WALL 42 IN. 72\" DIA. 7\" WALL 84\" DIA. 8\" WALLZ-LOK STM for Flat Wall Z-LOK STM for Radius Wall

The Company With Connections® TMPIPE TO MANHOLE BOOT CONNECTOR FOR SANITARY SYSTEMS Patent PendingQUIK•LOK “The Boot with the Built-in Clamp”QUIK•LOKThe QUIK•LOK Pipe to QUIK-LOK boot as it will arrive QUIK-LOK boot cast into QUIK-LOK boot extended at jobManhole Boot Connector is a with clamp attached ready toflexible connector specifically structure in shipping position. site ready for pipe.engineered to produce a be placed in a mandrel.positive watertight seal forpipes entering precast concrete PERFORMANCE STANDARDstructures and the structureitself. The QUIK•LOKCONNECTOR is manufacturedto meet or exceed all materialand test requirements set forthin ASTM C-923 titled“Resilient ConnectorsBetween Reinforced ConcreteManhole Structures, Pipes,and Laterals”. MATERIALThe QUIK•LOK Connector is molded from an EPDM compound The QUIK•LOK CONNECTOR meets or exceeds all material and testengineered to conform with the requirements of section 4.1.1 of requirements of ASTM C-923 titled “Resilient Connectors BetweenASTM C-923. Alternative compounds are available for unusual Reinforced Concrete Manhole Structures, Pipes, and Laterals”.applications upon special order. See following chart:All stainless steel hardware is in compliance with section 4.2,“Mechanical Devices” of ASTM C-923. RESILIENT MATERIAL TEST OF ASTM C-923 KEY ADVANTAGES TEST RESULTS ASTM METHOD Chemical resistance D 543The QUIK•LOK CONNECTOR assures a positive watertight connection no weight loss at 22°C for 48hand provides up to 20° degrees omni-directional deflection and 1.00\" of 1 N Sulfuric acid no weight lossvertical or horizontal movement without loss of seal. This deflection 1 N Hydrochloric D 412permits pipe to structure settling without damage to the pipe or loss of Acid 1200 psi orthe watertight seal and will also allow for many angles of incoming pipe. Tensile strength 8.5 MPa, min D 2240 Elongation at break 350% min. (Shore AThe QUIK•LOK cast in Boot Connector is manufactured with the Hardness ±5 from mfg’s. durometer)stainless steel takedown clamp as an integral part of the rubber specified hardness D 573,connector. Accelerated 70±1°C for oven-aging decr. of 15%, 7 daysThe correct takedown clamp travels in the installation position from the max. of originaltime it leaves A-LOK, while it is cast in the structure and until it arrives Compression set tensile strength, D 395, Method B,at the job site. After pulling out the connector it’s in position ready to be decr. of 20% at 70°C for 22htightened down around the pipe on the outside of the structure. Water absorption max. of elongation D 471, immerse decr. of 25%, 0.75 by 2-in. orImmediate backfilling is then possible, enhancing project safety and max. of original 19 by 25-mmovercomes the problems encountered with water, running sand and deflection Specimen inother unstable trench conditions. increase of 10%, distilled water max. of original at 70°C for 48hThe QUIK•LOK Connector can be installed into concrete structures in by weight D 1171the plant or with a field sleeve for cast-in-place, at the job site. Once D 746installed in the concrete structure and ready to ship, the QUIK•LOK Ozone resistance rating 0 D 624, Method BConnector travels in the cast in position to prevent damage during Low-temp no fracture atshipping and handling. brittle point -40°C Tear resistance 200 lbf/in. or 34 kn/m Copyright ASTM INTERNATIONAL. Reprinted with permission

PRODUCT REFERENCES PRODUCT SPECIFICATIONSA.) ASTM C-923 A flexible pipe to manhole connector shall be used whenever a pipeResilient Connectors Between Reinforced Concrete Manhole penetrates into a precast concrete manhole or structure.Structures, Pipes, and Laterals. The connector shall be the QUIK•LOK CONNECTOR as manufactured by A•LOKB.) ASTM C-1244 PRODUCTS, INC., Tullytown, PA, or approved equal.Standard Test Method For Concrete Sewer Manholesby the Negative Air Pressure (Vacuum) Test The design of the connector shall provide a flexible, watertight seal between the pipe and concrete structure. The connector shall assure that a seal is made between:C.) ASTM C-478Standard Specification for Precast Reinforced Concrete (1) The connector and the structure wall by casting the connectorManhole Sections integrally with the structure wall during the manufacturing process in a manner that it will not pull out during pipe coupling.PART 6 • DIMENSIONAL DATA (2) The seal between the connector and the pipe shall be made by compressing QUIK•LOK PIPE OD PIPE OD the connector against the outside circumference of the pipe by means of a RING NO. MIN. MAX. stainless steel take-down band. 4\" 4.75\" QL-04 6\" 6.875\" The connector shall be made from materials that conform to the physical and QL-06 8\" 9.10\" chemical requirements outlined in Section 4, “Materials and Manufacture” of QL-08 10\" 11.25\" ASTM C-923 “Standard Specification for Resilient Connectors Between QL-10 12\" 13.00\" Reinforced Concrete Manhole Structures, Pipes, and Laterals,” and the overall QL-12 design will meet or exceed Section 7, “Test Methods and Requirements” of ASTM C-923. The connector shall be sized specifically for the type of pipe being used and shall be installed in accordance with the recommendations of the manufacturer.INSTALLATION INSTRUCTIONSSTEP 1 STEP 3 STEP 1: Remove all sharp edges STEP 3: Center pipe and insert. on pipe, bevel edge and clean penetrating pipe section.STEP 2 STEP 4 STEP 2: Pull out connector from STEP 4: After inserting pipe, the cast position and clean stainless steel band should off debris (stones, dirt, be tightened with the etc.) that could weaken torque wrench to 60 in.-lb., the sealing area. then deflect pipe to flow or angle installation requires.WARNING: To ensure the QUIK•LOK Connector remains a flexible watertight connector, it is A•LOK Products, Inc. strongrecommendation that no mortar be placed between the pipe and wall of the concrete structure. The use of mortar in this area woulddecrease the effectiveness of the connector to compensate for shear caused by settlement or ground movement.NOTE: The 60 in.-lb. Torque Wrench is available through A•LOK Products, Inc.CAUTION: When installing pipe stubs for future pipeline installation, all stubs must be properly restrained to prevent any movement bymeans other than the QUIK•LOK Connector. ANY QUESTIONS REGARDING QUIK•LOK CONNECTOR INSTALLATION, PLEASE CALL 1-800-822-2565©2006 A-LOK Products, Inc. Supersedes all previous literature. COVERED BY ISSUED AND/OR PENDING PATENTS A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX 8/06

SNUG DOWN IN PLACE UNTIL REMEMBER TO REMOVE BLACK MAGNET IN UPWHITE ALIGNMENT PEGS ARE THROUGH HOLES MAGNET PROTECTIVE COVER POSITION MAKES THIS8 9PLACE MANDREL WITH 10 WHITE HALF AGAINST CORE MANDREL READY AND MAGNET HANDLE AT FOR CORE MOUNT 12 O’CLOCK REMOVE MAGNET – STRIP OUT MANDREL BY USING READY TO SHIP – FOLDED INSIDE WALL THE COMPANY WITH CONNECTIONS® DEAD BLOW HAMMER TO HIT WHITE ALIGNMENT PEGS – CLAMP MECHANISM AT 12 O’CLOCK A•LOK PRODUCTS INCORPORATED P.O. Box 1647 • 697 Main Street Tul ytown, PA 19007 800-822-2565 • 215-547-3366 215-547-5260 FAX www.a-lok.com • email: [email protected]

How To Install A Quik-Lok Connector On A Quik-Lok Mandrel INSIDE (CORE) 1 2 3 MANDREL HALF ORIENT CLAMP TAKE DOWN QUIK-LOK CONNECTOR MECHANISM/WORM DRIVE TOWARDS TOP OF MANDREL CLAMP TAKE DOWNOUTSIDE (JACKET) MECHANISMMANDREL HALF MAGNET & HOLDER INSERT QUIK-LOK CONNECTOR QUIK-LOK INSERTED IN PUT OUTSIDE (BLACK) DOWN IN CORE/WHITE MANDREL HALF WHITE MANDREL HALF MANDREL HALF INSIDE THE PARTS QUIK-LOK CONNECTOR4 5 BRUSH FORM RELEASE ON 6 OUTSIDE OF BOTH 7 MANDREL HALVES

The Company With Connections®ON SITE WASTEWATER Z-LOK® C104-4 CONNECTORSEPTIC TANK CONNECTORS A•LOK SEPTIC TANK CONNECTORS X-CEL™ 9091 CONNECTORX-CEL™ ON MANDREL CAST IN ATTACHED TO FORM CONNECTOR CLAMPED DOWN ON PIPE TO CREATE WATERTIGHT CONNECTION KEY ADVANTAGES CONNECTOR ROLLED BACK ON MANDRELLet A•LOK® Products, the recognized leader in ATTACHED TO FORMthe manufacturer of watertight connectors, showyou profitable, cost-effective septic connectors PART 6 • DIMENSIONAL DATAthat work! PIPE 9091 X-CEL™ C104-4 Z•LOK®• Simple and easy to use• Cost-effective 1.5\" Schedule 40 X• Compatible with wet and dry applications• One-piece hole former 2.0\" Schedule 40 X PRODUCT REFERENCES 4.0\" Schedule 40 X XMEETS OR EXCEEDS REQUIREMENTS OF ASTM C-923 4.0\" SDR 35 X XA•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX





The Company With Connections® TMCORROSION PROTECTION FOR CONCRETE STRUCTURESDURA PLATE 100 LINER SYSTEM A•LOK DURA PLATE 100 LINER SYSTEM PERFORMANCE STANDARDThe Duraplate 100 Liner The Dura Plate 100 Liner meets or exceeds all material and testis a corrosion protection requirements as outlined by the manufacturer.system for concretestructures used in Chemical Resistant: Solutionwastewater, stormwater Chemical 20%and light industrial Sulfuric Acid (H2SO4) 5%applications. It is an Sodium Hydroxide (NaOH) 5%extremely durable as well Ammonium Hydroxide (NH3OH) 1%as resilient PVC polymer Nitric Acid (HNO3) 1%blend material that is Ferric Chloride (FeCl3)thermoformed into a Soap 0.10%sectional design. The Detergent 0.10%compression joints allowfor secure installation of Physical Properties of Liner Panel:the sections during thePrecast process and Test ASTM Minimumeliminate the need for welding. Value Method 6,100 psi MATERIAL 28.5 % Tensile D-638The liner and seals are all formed from materials selected for their 325,000 psichemical resistance properties. The main panel sections are formed Elongation D-638 9,200 psifrom a polymer blend, while the vertical panel joints are sealed withan EPDM rubber, and the horizontal structure joints with an approved Tensile Modulus D-638 340,000 psipreformed butyl sealant. 640 in-lbf Flexural Strength D-790 KEY ADVANTAGES Flexural Modulus D-790The Dura Plate 100 Liner System was designed on a three pointdesign philosophy. Tensile Impact D-18221) The system will provide corrosion protection to the concrete PRODUCT SPECIFICATIONS substrate, by shielding it with a protective barrier of inert material embedded to the inside wall of the structure. Each A protective liner shall be used whenever a precast concrete manhole or panel features a minimum ½”return on each edge to ensure structure is used in a sanitary or light industrial sewer system in which the proper sealing. potential for corrosive attack to the concrete substrate exists.2) The design will minimize the freight cost by using a sectional The liner shall be the Dura Plate 100 Liner as manufactured by A-LOK® design that will allow the pieces to be nested within each other Products, Inc., Tullytown, PA or approved equal. while being shipped to the precaster. The design of the liner shall provide a corrosion protective barrier permanently3) The design will provide easy installation without the need for embedded to the inside wall of the structure. The liner system shall assure welding sections together, but still providing complete corrosion that: protection to the structure. 1) The liner shall become an integrally part of the structure wall by casting the liner with the structure during the manufacturing process. The liner shall also be capable of being cast into a round structure by curving the liner in a manner that allows it to remain permanently attached to the inside structure wall. 2) Vertical joints between the liner sections shall be made by the mechanical compression of a EPDM rubber strip between the returns of the two panels with self tapping screws spaced every 3 inches apart. 3) Horizontal joints between structure sections shall be sealed with an approved butyl strip compressed between the sections in a manner as recommended by the manufacturer. 4) The liner system shall be composed from materials that are corrosion resistant by nature and conforms to the physical and chemical requirements as determined by the manufacturer. 5) The liner shall be sized specifically for the type of structure being used and shall be installed in accordance with the recommendations of the manufacturer.

PRECAST INSTALLATION INSTRUCTIONS 5 2 13 12 1. Inspect core for sharp or jagged edges that could damage the liner during the shipping process. 2. Place Dura Plate 100 Liner panels level around the core of the form. Form release agent is not necessary. 3. Install the vertical joints by placing the black rubber strip between the panel returns, making sure that the flap of the strip is fitted over one of the returns. 4. Place backing plate on the inside return of panel that the flap fits over. Hold together with spring loaded clamps evenly spaced about 12\" apart. 5. Secure the panels together with fasteners placed every 3 inches, making sure that each fastener is tightened to 5 in-lbs. Note: The fasteners must be installed from the side opposite the flap, straight thru the backing plate, parallel to the liner. 6. Repeat for all seams. Note: Caulk can be placed between the form core and liner returns to minimize concrete seepage during production. 7. Install reinforcement into form with any other necessary parts needed for the structure. 8. Pour concrete around the liner evenly to prevent shifting of the liner. 9. Vibrate and compact the concrete in a manner that will protect the liner and produce a dense, homogenous structure.10. Take precaution to protect the liner from sharp or jagged objects while stripping from the form.11. Visually inspect the liner after production for any cuts or tears. If repairs are needed, refer to Dura Plate 100 Liner repair bulletin for proper repair procedures.12. If steps or ladders are to be installed, drill all holes in liner larger than the diameter of the step. Install steps or ladder then caulk area around step and liner with FR500 caulking material (Lap Sealant).13. Protect all hole opening surfaces with a minimum 1/8 inch coverage of Sewer Guard that overlaps the liner at least a 1½ inches. JOB SITE INSTALLATION INSTRUCTIONS 1. When unloading the structure be careful. Take measures to protect the liner from being damaged by rocks or other debris. Lift carefully, do not drag. 2. Clean and install butyl strips around the joint design making sure that the butyl overlaps both the cement and liner return. 3. Carefully seat each section together making sure enough pressure is applied to seal the joint. 4. After structure is in place, plug all lift pin inserts and holes with suitable non-shrink grout. 5. If any damage to the liner occurs at the job site, use Dura Plate 100 Liner repair bulletin for proper repair procedures. WARRANTY A-LOK® Products, Inc. warrants that the product described in this bulletin meets or exceeds all material, quality, and workmanship standards suitable for its intended use. A-LOK® Products, Inc. liability is limited to replacement or repair of defective parts excluding cost of removal, installation or unauthorized repairs. A-LOK Products, Inc. will not be responsible for incidental or consequential damages or for products which have been altered or modified. No representative of the company, or any other person, has the authority to waive, alter or add to this guarantee or to assume for the company any obligation with the sale or installation of A-LOK Products, Inc. This warranty is in lieu of all other warranties, expressed or implied. ANY QUESTIONS REGARDING A•LOK DURA PLATE 100 LINER SYSTEM INSTALLATION, PLEASE CALL 1-800-822-2565A•LOK PRODUCTS INCORPORATED P.O. BOX 1647 • 697 Main Street • Tullytown, PA 19007 • www.a-lok.com • email: [email protected] 800-822-2565 • 215-547-3366 • 215-547-5260 FAX

DURA PLATE 100 LINER CORROSION RESISTANT SYSTEM moforming to the contour of the structure Chemical Resistant: and shall maintain a minimum wall thick- ness of .065 inches. Chemical Solution 2.3 Rubber Joint Composition - Sulfuric Acid (H2SO4) 20% The fabricated liner panels shall be joined together by a slotted strip of EPDM rub- Sodium Hydroxide (NaOH) 5% ber according to the manufacturer’s spec- ification as illustrated in Figure 1A. Ammonium Hydroxide (NH3OH) 5% Figure 1A - Panel Joint Detail Nitric Acid (HNO3) 1% 2.4 Butyl Joint Composition - Ferric Chloride (FeC13) 1% Sections of lined concrete structures shall be joined together by an approved butyl Soap 0.10% strip (A-LOK® Products, Inc. Tullytown, PA. MT-329) designed to produce suffi- Detergent 0.10% cient squeeze-out between PVC returns. Note: All EPDM and Butyl joint com- Physical Properties of Liner Panel: pound shall be formulated to meet the chemical resistant properties of Section ASTM Minimum 3.1.1. Test Method Value Part 3. Physical Properties Tensile D-638 6,100 psi 3.1 General - All materials shall Elongation D-638 28.5% meet the physical and chemical resistantPart 1. The Dura Plate 100 Liner properties specified in the following Tensile Modulus D-638 325,000 psi System appropriate section. Flexural Strength D-790 9,200 psiThe objective of this specification is to 3.1.1 Physical Properties - All semi-cover the supply and installation of a vac- rigid liner sheets, joint assembly compo- Flexural Modulus D-790 340,000 psiuum formed semi-rigid liner for use in nents, corner and weld strips shall havewastewater and light industrial concrete the following properties when tested at 77 Tensile Impact D-1822 640 in-lbstructures to effectively shield the interior degrees +/- 5 degrees Fahrenheit.of the structure from corrosion. 3.1.2 Antifungal and Antibacterial Properties - Dura Plate 100 Liner shall beThe design of the liner system shall insure made from Acrylic PVC Alloy sheets thatthat it will conform to the contour of the resist bacteriological and fungal develop-structure and form a permanent mechani- ment. Sheet shall not readily provide acal bond to the concrete through use of source of nutrients for bacteria and fungi.preformed horizontal ribs and dovetails. Plasticizers that allow a source of nutri-The liner will be formed in such a manner ents which support microbial growth forthat the joints between the structure sec- bacterial or fungal growth shall not betions will be afforded protection through permitted.the use of a continuous PVC return intothe joint for a minimum of .50 of an inch. Sheet shall be subjected to fun-Provisions will be made to allow the pipe gus resistance testing in accordance withpenetrations to be sealed by applying a ASTM G-21 and bacteria resistance test-cementitious corrosion resistant material ing in accordance with ASTM G-22,to the unlined exposed areas within the Procedure B.openings. Fungus Resistance Testing,Part 2. Material ASTM G-21: Eighteen day cultures of the following pure culture fungi were har- 2.1 Liner shall be Dura Plate 100 vested, washed and their spore countsas manufactured by A-LOK® Products, adjusted to 1,000.000 (±200,000 per ml).Incorporated, Tullytown, Pennsylvania. Organism ATCC Number 2.2 Liner Composition - The liner,channel joints, H-joints and corner joints Aspergillus niger 9642shall be manufactured from an AcrylicPVC Alloy. Penicillium pinophilum 11797 All sheet compound will result Gliocladium virans 9645in a semi-rigid material suitable for ther- Aureobasidum pullulans 15233 Chaetomium globosum 6205 The spore suspensions were combined and sprayed on the samples and controls which were placed on mineral salts agar and placed in the test chamber. –1–

The samples, along with controls were Part 4. Details and Dimensions of 5.3 The liner panels when assem-incubated for 28 days and examined Standard Liner bled shall form a circular cylinder that fitsweekly. snugly against the inner steel core of the 4.1 Liner panels shall have a min- form. A removable extruded rubber pro-Sample Observations imum thickness of .065 inches. A combi- file or suitable one-sided tape can be used nation of standing ribs and mechanical to seal the liner against the core to preventDesignation (Rating*) dovetails shall be used to secure the liner concrete fines from washing down panels to the wall of the structure and between the liner and steel core.Thermoplastic 7 14 21 28 shall be spaced a maximum of 6.0 inches apart. 5.4 Concrete poured around theSheet: Days Days Days Days liner shall be distributed evenly to prevent 4.2 Liner panels with a combina- shifting of the liner.#1 0 0 0 0 tion of standing ribs and dovetails in diameters of 48\" through 60\" shall be at 5.5 Concrete poured against the#2 0 0 0 0 least .50 inches high. Panels of 72\" diam- liner shall be vibrated, or compacted in a eter and above shall be at least .75 inches manner to protect the liner and produce a#3 0 0 0 0 high. dense homogenous concrete to securely anchor the assembly to the exposed sur-#4 0 0 0 0 4.3 Liner with locking extensions faces on the interior of the structure. shall be able to withstand a test pull of 100Controls: pounds per linear inch applied perpendi- 5.6 When extracting the steel core, cular to the concrete surface for a period care should be taken to protect the linerFilter Paper 4 4 4 4 of 60 seconds. No rupture of the locking from damage. Instruments with sharp or extensions or withdrawal from embed- jagged edges should not be used to releaseGlass Slides 0 0 0 0 ment shall be acceptable. This test shall be the forms from the liner. made at a temperature between 70 and 80*Rating: 0=no growth. 1=traces, degrees Fahrenheit inclusive. 5.7 Visual inspection of the liner shall be made after demolding and any2=light, 3=moderate, 4=heavy growth 4.4 Liner panels shall be formed to cuts or tears shall be repaired by follow- the correct radius to assure a true diameter ing the manufacturer’s repair recommen- Bacteria Resistance Testing, match between joined precast sections dations.ASTM G-22: Conclusion of Fungus when assembled.Resistance Testing: The sheet samples 5.8 The concrete producer shalldid not allow any fungus growth (rating 4.5 Liner panels shall be formed take all necessary measures to preventof 0). with a continuous return into the joint for damage due to casting, demolding, and a minimum of .50 of a inch which shall delivery of the lined concrete structure. A twenty-four hour culture of afford protection between the lined pre-Pseudomonas aeruginosa (ATCC 13388) cast sections. Part 6. Field Installation of Liningwas harvested and washed three times bycentrifugation using sterile distilled water. 4.6 All radius panels shall be vac- 6.1 General - Field installation ofThe bacterial suspension was added to uum tested for pinholes during the mold- all lined precast sections shall be done insterile, melted minerals salts agar, mixed ing process and shall withstand a mini- accordance with the recommendations ofand plates poured. A sample of the inocu- mum of 25 inches of mercury for a period the manufacturer.lated agar was taken and a plate count to of 60 seconds.determine the number of viable 6.2 The horizontal joints betweenpseudomonas present. 4.7 Panel sections shall be custom sections of lined concrete structures can formed to a specified height not to exceed be made by either butyl or a combinationSample Observations 6' in overall length. Lengths specified of butyl and rubber joint per the recom- shall include a tolerance ratio of +/- .0625 mendation of the concrete manufacturer.Designation (Rating*) per foot. (See Fig. 2)Thermoplastic 7 14 21 Part 5. Plant Installation of Liner Figure 2 - Butyl JointSheet: Days Days Days 5.1 General - Installation of all lin- ing shall be done in accordance with the#1 0 0 0 manufacturer’s recommendations.#2 0 0 0 5.2 Lining coverage shall not be less than the minimum shown on the#3 0 0 0 approved shop drawings or construction plans.#4 0 0 0 –2–Controls:Inoculated Agar 0 0 0Glass Slides 0 00Plate Count Agar 1 1 1*Rating: 0=no growth, 1=growth Conclusion of BacteriaResistance Testing: The sheet samplesdid not allow any bacterial growth (ratingof 0).

6.3 Joint surfaces must be clean to 6.7 The installing contractor shallensure proper adhesion of the butyl. An take all necessary measures to preventapplication of a butyl based primer will damage to the liner due to material han-produce the highest degree of adhesion to dling, installation, or equipment or mate-the joint surfaces. rial used in installing, or used in or taken through the structure. Figure 2A - Spigot Up Joint Detail Part 7. Testing and Inspection Figure 4A - Drilled Hole Detail for Steps or Ladders 6.4 Place specified butyl material 7.1 General - This section coversas indicated in Figures 2A and 3A. Butt the in-plant and field inspection and test- Figure 5ends of material together. Material should ing method of lined concrete sections. 8.2 Hole Linersnever be overlapped. Butyl material shall 8.2.1 Pipe penetrations through thebe an approved strip per Section 2.4. 7.2 The liner manufacturer shall lined wall shall be afforded protection by test each panel to withstand a constant applying .125 inch trowelable, chemical vacuum of 25 inches of mercury for a and corrosion resistant epoxy mortar to period of 60 seconds. Any sections failing the unlined exposed areas within the to meet this requirement shall be rejected. openings and shall overlap the liner wall a minimum of 1.50 inches as illustrated in 7.3 In-plant inspections of panels Figure 5A. cast into concrete sections shall be visual- ly inspected for cuts or tears and shall be Epoxy Liner repaired following the manufacturers rec- Protection Of ommendations. Hole Opening. Part 8. Liner Appurtenances 8.1 Steps or Ladders 8.1.1 Steps shall be attached by either casting a preformed polypropylene insert to accept a polypropylene drive in step (Fig. 4), or by casting or drilling a precise hole to accept a polypropylene press fit step (Fig. 4A), as per the recom- mendations of the step manufacturer. 8.1.2 After installation of either the steps or ladders, the junction point of the device and the liner shall be sealed by applying an approved butyl caulking material (A-LOK® Products, Inc., Tullytown, Pennsylvania, Lap Sealant). Figure 3A - Bell Up Joint Detail Figure 4 - Casting in Polypropylene Figure 5A - Hole Liner Detail Step Insert 6.5 Lined sections should be care- 8.3 Grade Work Protectionfully centered and lowered to complete –3–coupling process. Apply sufficient pres- 8.3.1 Corrosion protection betweensure to properly seat joint and achieve the lined concrete structure and the castsqueeze out. iron frame and cover shall be obtained through the use of a telescoping Liner 6.6 After structure is in place, care System (A-LOK® Products, Inc.,should be taken to properly plug all liftpin inserts or holes with a suitable non-shrink grout.


Like this book? You can publish your book online for free in a few minutes!