Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore Venfilter-EN-imprenta-2020 02 07 VERSION 20 digital

Venfilter-EN-imprenta-2020 02 07 VERSION 20 digital

Published by emfasi, 2021-02-23 07:18:35

Description: Venfilter-EN-imprenta-2020 02 07 VERSION 20 digital

Search

Read the Text Version

Comfort Products Dimensions 0 Certification Plastic Varipleat INFORMA- TION Air Treatment 1 Air Treatment Units (Self-contained Air Conditioning Units, Air Conditioning and Ventilation Units), Industrial PRE- Processes (Pharmaceutical Ind., Microelectronics, Optics, FILTERS Food Ind., Veterinary Medicine, Fine Chemistry, etc.) 2 Technical features PAINTINGS Type: High Efficiency Compact Filter. BOOTHS Frame: Plastic. Filtering Element: Fiberglass paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Average Efficiency: 40% ≤ Em < 60%, 60% ≤ Em < 80%, 80% PRODUCTS ≤ Em < 90%, 90% ≤ Em < 95% and 95% ≤ Em EN 779 Class: M6, F7, F8 and F9. 4 ISO 16890: ePM10 60%, ePM1 50%, ePM1 65% and ePM1 80%. Recommended Final Pressure Pressure Drop: 450 Pa. EPA/HEPA Temperature: 80ºC, in continuous service. /ULPA Advantages 5 - Rigid construction, facilitating the installation and subs- HIGH titution of GRAVIMETRICS FILTERS. TEMPERA- - These filters are fully interchangeable with pre-existing filters, without the need to modify CTA frames. TURE - A High-efficiency, lightweight, Ultra-compact filter used in narrow spaces (48 and 96 mm.). 6 - Filter area, 10 times larger than Quebraven filters. - Reduced operating costs. - Lower maintenance, its EQUIP- working life is twice that of a Quebraven G4. - All parts MENTS are anti-corrosion and Incinerable (they do not emit toxic gases when burns during the incineration process in 7 municipal waste facilities). -Suitable for food industry. MOTORS AND Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com TURBINES Fax +34 937 862 493 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- 99 NATONAL NORMATI- VE

0 Comfort Products INFORMA- References TION Reference Dimensions EN *ME ISO 16890 Filter Nominal Initial Chamber Weigth UxP* Stock* 1 BxHxP 779 % Surface flow Pa volum (kg) VPLPL232304F9 Class ePM1 80% PRE- VPLPL112304F9 592x592x96 78 ePM1 80% (m2) (m3/h) 150 0,4 5 5F FILTERS VPLPL242404F9 287x592x96 F9 ePM1 80% 11 3000 0,2 2,5 10 F VPLPL122404F9 610x610x96 ePM1 80% 5,6 1500 0,4 5 5F 2 VPLPL232302F9 305x610x96 F9 78 ePM1 80% 11,6 3200 0,2 2,5 10 F VPLPL112302F9 592x592x48 ePM1 80% 5,8 1600 4 10 F PAINTINGS VPLPL242402F9 287x592x48 F8 65 ePM1 80% 6 2000 145 0,02 2 20 F BOOTHS VPLPL122402F9 610x610x48 ePM1 80% 3 1000 0,01 4 10 F VPLPL232304F8 305x610x48 F8 65 ePM1 65% 6,3 2100 0,02 2 20 F 3 VPLPL112304F8 592x592x96 ePM1 65% 3,15 1050 0.01 5 5S VPLPL242404F8 287x592x96 F7 53 ePM1 65% 11 3000 2,5 10 F COMFORT VPLPL122404F8 610x610x96 ePM1 65% 5,6 1500 105 0,4 5 5S PRODUCTS VPLPL232302F8 305x610x96 F7 52 ePM1 65% 11,6 3200 0,2 2,5 10 F VPLPL112302F8 592x592x48 ePM1 65% 5,8 1600 0,4 4 10 F 4 VPLPL242402F8 287x592x48 M6 ePM1 65% 6 2000 0,2 2 20 F VPLPL122402F8 610x610x48 ePM1 65% 3 1000 4 10 F EPA/HEPA VPLPL232304F7 305x610x48 M6 ePM1 55% 6,3 2100 100 0,02 2 20 F /ULPA VPLPL112304F7 592x592x96 ePM1 55% 3,15 1050 0,01 5 5S VPLPL242404F7 287x592x96 ePM1 55% 11 3000 0,02 2,5 10 S 5 VPLPL122404F7 610x610x96 ePM1 55% 5,6 1500 0,01 5 5F VPLPL232302F7 305x610x96 ePM1 50% 11,6 3200 2,5 10 F HIGH VPLPL112302F7 592x592x48 ePM1 50% 5,8 1600 90 0,4 4 10 S TEMPERA- VPLPL242402F7 287x592x48 ePM1 50% 6 2000 0,2 2 20 S VPLPL122402F7 610x610x48 ePM1 50% 3 1000 0,4 4 10 S TURE VPLPL232304F6 305x610x48 ePM10 65% 6,3 2100 0,2 2 20 S VPLPL112304F6 592x592x96 ePM10 65% 3,15 1050 5 5S 6 VPLPL242404F6 287x592x96 ePM10 65% 11 3000 80 0,02 2,5 10 S VPLPL122404F6 610x610x96 ePM10 65% 5,6 1500 0,01 5 5S EQUIP- VPLPL232302F6 305x610x96 ePM10 60% 11,6 3200 0,02 2,5 10 F MENTS VPLPL112302F6 592x592x48 ePM10 60% 5,8 1600 0,01 4 10 S VPLPL242402F6 287x592x48 ePM10 60% 6 2000 2 20 S 7 VPLPL122402F6 610x610x48 ePM10 60% 3 1000 80 0,4 4 10 S 305x610x48 6,3 2100 0,2 2 20 S MOTORS 3,15 1050 0,4 AND 0,2 TURBINES 65 0,02 0,01 8 0,02 0,01 ADSOR- TION AND *UxP *Stock *ME%: Minium Efficiency to EN779:2012 DESODO- Units per box F: Manufacturer, S: Stock, SL: Limited Stock RIZATION Venfilter 9 100 Tel +34 937 862 607 [email protected] INTER- Fax +34 937 862 493 www.venfilter.com NATONAL NORMATI- VE

Comfort Products Dimensions 0 Certification Varipleat double INFORMA- metal grid TION Air Treatment 1 Prefilter or filter for air conditioners, air inlets, mini air PRE- treatment plants for power, industrial and commercial FILTERS installations. 2 Technical features PAINTINGS Type: High Efficiency Compact Filter. BOOTHS Frame: Galvanised steel. Protective grilles on both sides. Filtering Element: Fiberglass paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Average Efficiency: 60% ≤ Em < 80%, 80% ≤ Em < 90%, PRODUCTS 90% ≤ Em < 95% and 95% ≤ Em. EN 779 Class: M6, F7, F8 and F9. 4 ISO 16890: ePM10 60%, ePM1 50%, ePM1 65% and ePM1 80%. Recommended Final Pressure Pressure Drop: 450 Pa. EPA/HEPA Temperature: 80ºC, in continuous service. /ULPA Advantages 5 - Rigid construction, facilitating the installation and subs- HIGH titution of GRAVIMETRICS FILTERS. TEMPERA- - These filters are fully interchangeable with pre-existing filters, without the need to modify CTA frames. TURE - A High-efficiency, lightweight, Ultra-compact filter used in narrow spaces (48 and 96 mm). 6 - Filter area, 10 times larger than Quebraven filters. - Reduced operating costs. EQUIP- - Lower maintenance, its working life is twice that of a MENTS Quebraven G4. - All parts are anti-corrosion and Incinerable (they do not 7 emit toxic gases when burns during the incineration pro- cess in municipal waste facilities). MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 101 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Comfort Products INFORMA- References TION Reference Dimensions EN 779 *ME ISO 16890 Filter Nominal Initial Chamber Weigth UxP* Stock* 1 % Surface flow Pa BxHxP Class ePM1 80% 150 volum (Kg) F PRE- ePM1 80% (m2) (m3/h) 145 F FILTERS VPLDR232304F9 592x592x98 F9 78 ePM1 80% 11 3000 105 0,4 5 5 F VPLDR112304F9 287x592x98 F9 78 ePM1 80% 5,6 1500 0,2 2,5 10 F 2 VPLDR232302F9 592x592x48 F8 65 ePM1 80% 6 2000 100 0,02 4 10 F VPLDR112302F9 287x592x48 ePM1 65% 3 1000 90 0,01 2 20 F PAINTINGS VPLDR242402F9 610x610x48 F8 65 ePM1 65% 6,3 2100 80 0,02 4 10 F BOOTHS VPLDR232304F8 592x592x98 F7 53 ePM1 65% 11 3000 0,4 5 5 F VPLDR112304F8 287x592x98 F7 52 ePM1 65% 5,6 1500 80 0,2 2,5 10 F 3 VPLDR242404F8 610x610x98 ePM1 65% 11,6 3200 0,4 5 5 F VPLDR122404F8 305x610x98 M6 ePM1 65% 5,8 1600 65 0,2 2,5 10 F COMFORT VPLDR232302F8 592x592x48 ePM1 50% 6 2000 0,02 4 10 F PRODUCTS VPLDR112302F8 287x592x48 M6 ePM1 50% 3 1000 0,01 2 20 F VPLDR232304F7 592x592x98 ePM1 50% 11 3000 0,4 5 5 F 4 VPLDR112304F7 287x592x98 ePM1 50% 5,6 1500 0,2 2,5 10 F VPLDR232302F7 592x592x48 ePM1 50% 6 2000 0,02 4 10 F EPA/HEPA VPLDR112302F7 287x592x48 ePM1 50% 3 1000 0,01 2 20 F /ULPA VPLDR242402F7 610x610x48 ePM10 60% 6,3 2100 0,02 4 10 F VPLDR122402F7 305x610x48 ePM10 60% 3,15 1050 0,01 2 20 F 5 VPLDR232304F6 592x592x98 ePM10 60% 11 3000 0,4 5 5 F VPLDR112304F6 287x592x98 ePM10 60% 5,6 1500 0,2 2,5 10 F HIGH VPLDR242404F6 610x610x98 ePM10 60% 11,6 3200 0,4 5 5 F TEMPERA- VPLDR122404F6 305x610x98 ePM10 60% 5,8 1600 0,2 2,5 10 F VPLDR232302F6 592x592x48 ePM10 60% 6 2000 0,02 4 10 F TURE VPLDR112302F6 287x592x48 ePM10 60% 3 1000 0,01 2 20 F VPLDR242402F6 610x610x48 6,3 2100 0,02 4 10 6 VPLDR122402F6 305x610x48 3,15 1050 0,01 2 20 EQUIP- *UxP *Stock *ME%: Minium Efficiency to EN779:2012 MENTS Units per box F: Manufacturer, S: Stock, SL: Limited Stock 7 Venfilter MOTORS 102 Tel +34 937 862 607 [email protected] AND Fax +34 937 862 493 www.venfilter.com TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products Dimensions 0 Certification Varipleat Cardboard INFORMA- TION Air Treatment 1 Prefilter or filter for air conditioners, air inlets, mini air treatment plants for power, industrial and commercial PRE- installations. FILTERS Technical features 2 Type: High Efficiency Compact Filter. PAINTINGS Frame: Cardboard. BOOTHS Filtering Element: Fiberglass paper. Separators: Thermoplastic glue beads. 3 Sealant: Polyurethane. Average Efficiency: 60% ≤ Em < 80%, 80% ≤ Em < 90%, COMFORT 90% ≤ Em < 95% and 95% ≤ Em. PRODUCTS EN 779 Class: M6, F7, F8 and F9. ISO 16890: ePM10 60%, ePM1 50%, ePM1 65% and ePM1 80%. 4 Recommended Final Pressure Pressure Drop: 450 Pa. Temperature: 80ºC, en servicio continuo. EPA/HEPA /ULPA Advantages 5 - Rigid construction, facilitating the installation and subs- titution of GRAVIMETRICS FILTERS. HIGH - These filters are fully interchangeable with pre-existing TEMPERA- filters, without the need to modify CTA frames. - A High-efficiency, lightweight, Ultra-compact filter used TURE in narrow spaces (48 and 96 mm.). - Filter area, 10 times larger than Quebraven filters. 6 - Reduced operating costs. - Lower maintenance, its wor- king life is twice that of a Quebraven G4. - All parts are an- EQUIP- ti-corrosion and Incinerable (they do not emit toxic gases MENTS when burns during the incineration process in municipal waste facilities). 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 103 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Comfort Products INFORMA- References TION Reference Dimensions EN 779 *ME ISO 16890 Filter Nominal Initial Unit Weigth UxP* Stock* 1 BxHxP Class % Surface flow Pa Volume (kg) VPLC232304F9 150 PRE- VPLC112304F9 592x592x95 (m2) (m3/h) (m3) FILTERS VPLC242404F9 287x592x95 145 0,4 VPLC122404F9 610x610x95 F9 78 ePM1 80% 11 3000 0,2 5 5F 2 VPLC232302F9 305x610x95 105 0,4 2,5 10 F VPLC112302F9 592x592x45 ePM1 80% 5,6 1500 0,2 5 5F PAINTINGS VPLC242402F9 287x592x45 100 0,02 2,5 10 F BOOTHS VPLC122402F9 610x610x45 ePM1 80% 11,6 3200 0,01 4 10 F VPLC232304F8 305x610x45 90 0,02 2 20 F 3 VPLC112304F8 592x592x95 ePM1 80% 5,8 1600 0.01 4 10 F VPLC242404F8 287x592x95 80 0,4 2 20 F COMFORT VPLC122404F8 610x610x95 F9 78 ePM1 80% 6 2000 0,2 5 5F PRODUCTS VPLC232302F8 305x610x95 80 0,4 2,5 10 F VPLC112302F8 592x592x45 ePM1 80% 3 1000 0,2 5 5F 4 VPLC242402F8 287x592x45 65 0,02 2,5 10 F VPLC122402F8 610x610x45 ePM1 80% 6,3 2100 0,01 4 10 F EPA/HEPA VPLC232304F7 305x610x45 0,02 2 20 F /ULPA VPLC112304F7 592x592x95 ePM1 80% 3,15 1050 0,01 4 10 F VPLC242404F7 287x592x95 0,4 2 20 F 5 VPLC122404F7 610x610x95 F8 65 ePM1 65% 11 3000 0,2 5 5F VPLC232302F7 305x610x95 0,4 2,5 10 F HIGH VPLC112302F7 592x592x45 ePM1 65% 5,6 1500 0,2 5 5F TEMPERA- VPLC242402F7 287x592x45 0,02 2,5 10 F VPLC122402F7 610x610x45 ePM1 65% 11,6 3200 0,01 4 10 F TURE VPLC232304F6 305x610x45 0,02 2 20 F VPLC112304F6 592x592x95 ePM1 65% 5,8 1600 0,01 4 10 F 6 VPLC242404F6 287x592x95 0,4 2 20 F VPLC122404F6 610x610x95 F8 65 ePM1 65% 6 2000 0,2 5 5F EQUIP- VPLC232302F6 305x610x95 0,4 2,5 10 F MENTS VPLC112302F6 592x592x45 ePM1 65% 3 1000 0,2 5 5F VPLC242402F6 287x592x45 0,02 2,5 10 F 7 VPLC122402F6 610x610x45 ePM1 65% 6,3 2100 0,01 4 10 F 305x610x45 0,02 2 20 F MOTORS ePM1 65% 3,15 1050 0,01 4 10 F AND 2 20 F F7 53 ePM1 50% 11 3000 TURBINES ePM1 50% 5,6 1500 8 ePM1 50% 11,6 3200 ADSOR- TION AND ePM1 50% 5,8 1600 DESODO- RIZATION F7 52 ePM1 50% 6 2000 9 ePM1 50% 3 1000 INTER- ePM1 50% 6,3 2100 NATONAL NORMATI- ePM1 50% 3,15 1050 VE M6 ePM10 60% 11 3000 ePM10 60% 5,6 1500 ePM10 60% 11,6 3200 ePM10 60% 5,8 1600 M6 ePM10 60% 6 2000 ePM10 60% 3 1000 ePM10 60% 6,3 2100 ePM10 60% 3,15 1050 *UxP *Stock *ME%: Minium Efficiency to EN779:2012 Units per box F: Manufacturer, S: Stock, SL: Limited Stock Venfilter 104 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com

Comfort Products Dimensions 0 Certification Varipac INFORMA- TION Air Treatment 1 Panel Filters for Air Handling units (Autonomous Condi- tioners, Air Conditioning Units and Ventilation), Industrial PRE- Processes (Pharmaceutical Ind., Microelectronics, Optics, FILTERS Food, Veterinary, Fine Chemicals, etc.) 2 Technical features PAINTINGS Type: High Efficiency Dihedral Filter. BOOTHS Frame: Galvanized Steel. Filtering Element: Fiberglass paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Clamp or flange: Galvanized Steel. PRODUCTS Joint: liquid system of bi-component polyurethane. Average Efficiency % (Em): 60% ≤ Em < 80%, 80% ≤ Em < 4 90%, 90% ≤ Em < 95% and 95% ≤ Em. EN 779 Class: M6, F7, F8 and F9. EPA/HEPA ISO 16890: ePM2.5 50 %, ePM1 50%, ePM1 65% and ePM1 80%. /ULPA Recommended Final Pressure Pressure Drop: 450 Pa. Temperature: 80ºC, in continuous service. 5 Advantages HIGH TEMPERA- - This method of V-shaped pleating guarantees the optimum geometrical form of the pleats and a uniform distance be- TURE tween them. This allows to get the same filtering area as with the aluminum separators filters in order to obtain the same 6 airflows, similar pressure Pressure Dropes and the same fil- tration efficiency. EQUIP- - V-shaped pleat technology ensures that aluminum separa- MENTS tors may be replaced, thereby eliminating the risk of leaks due to perforations in the aluminum separators. 7 - The filter is light and it is used in narrow spaces. (135 mm.) - The uniform shape of the pleats ensures that the airflow MOTORS does not generate turbulence. AND - Ref. VPP have a flange or mark that adapts to pre-existing frames in the installations, without making any modifications TURBINES for new installations, the appropriate frames are the BRTM. - Plastic mark. 8 - Ref. VP have no flange and have a depth of 150 and 292 mm., For new installations, suitable racks are BTRA. ADSOR- - Galvanized steel mark. TION AND DESODO- Venfilter RIZATION Tel +34 937 862 607 Fax +34 937 862 493 9 [email protected] 105 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Comfort Products INFORMA- References TION Reference Dimensions EN *ME ISO 16890 Filter Nominal Initial Chamber Weight Energy Energy Energy Energy UxP Stock 1 BxHxP 779 % Surface flow Pa Volume Class (Kg) Class Class Cons. Cons. * * PRE- (m2) nominal (m3) FILTERS (m3/h) 779 16890 kWh/ kWh/ 12,4 2 9,7 3400 *** **** year year 6,2 2750 PAINTINGS 3,5 1700 779 16890 BOOTHS 12,4 850 9,7 3400 * ** 3 6,2 2750 VPP242405F9 592x592x130 F9 76 ePM1 80% 3,5 1700 175 C D 2300 2322 0.05 4,4 1 SL COMFORT VPP202405F9 492x592x130 F8 ePM1 80% 12,4 850 PRODUCTS VPP122405F9 292x592x130 F7 ePM1 80% 9,7 3400 CD 0,04 3,8 1 F VPP121205F9 292x292x130 M6 ePM1 80% 6,2 2750 4 VPP242405F8 592x592x130 3,5 1700 CD 0,03 2,4 1 F VPP202405F8 492x592x130 65 ePM1 65% 12,4 850 EPA/HEPA VPP122405F8 292x592x130 ePM1 65% 9,7 3400 CD 0,02 2,1 1 F /ULPA VPP121205F8 292x292x130 ePM1 65% 6,2 2750 VPP242405F7 592x592x130 ePM1 65% 3,5 1700 153 C E 1836 >2050 0,05 4,4 1 S VPP202405F7 492x592x130 850 VPP122405F7 292x592x130 52 ePM1 55% CE 0,04 3,8 1 SL VPP121205F7 292x292x130 ePM1 55% VPP242405F6 592x592x130 ePM1 55% CE 0,03 2,4 1 S VPP202405F6 492x592x130 ePM1 55% VPP122405F6 292x592x130 ePM10 60% CE 0,02 2,1 1 F VPP121205F6 292x292x130 ePM10 60% ePM10 60% 135 C D 1460 1869 0,05 4,4 1 F ePM10 60% CD 0,04 3,8 1 F CD 0,03 2,4 1 F CD 0,02 2,1 1 F 120 E E 1728 >1200 0,05 4,4 1 F EE 0,04 3,8 1 F EE 0,03 2,4 1 F EE 0,02 2,1 1 F 5 *UxP *Stock * ME%: Minimum Efficiency EN779: 2012 * Energy Consumption kWh / year: Calculated according to Eurovent 4 / 21-2017 guidelines. HIGH Units per box F: Manufacturer, S: Stock, SL: Limited Stock TEMPERA- ** Energy Consumption kWh / year: Calculated according to Eurovent guidelines. **** Energy class according to Eurovent. TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- 106 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products 0 Poliven INFORMA- TION Air Treatment 1 Filters panel galvanized steel frame for Air Handling units (Autonomous Conditioners, Air Conditioning and Ventila- PRE- tion Units), Industrial Processes (Pharmaceutical Indus- FILTERS try, Microelectronics, Optics, Food, Veterinary, Fine Che- micals, etc.) 2 Technical features Dimensions PAINTINGS BOOTHS Type: Compact multi-dihedral high efficiency filter large filter surface. 3 Frame: Galvanized steel. Filtering element: glass fiber paper. COMFORT Separators: Cords Thermoplastic tail. PRODUCTS Sealant: Polyurethane. Joint: Liquid two-component polyurethane system. 4 Average Efficiency % (Em): 60% ≤ Em <80%, 80% ≤ Em <90%, 90% ≤ Em <95%. EPA/HEPA EN 779 Class: M6, F7, F8 and F9. /ULPA ISO 16890: ePM10 70%, ePM1 55%, ePM1 70% and ePM1 80%. Lost Final Recommended Load: 450 Pa. 5 Temperature: 80ºC in continuous service. HIGH Advantages TEMPERA- - Large filter surface. TURE - Large flow-up to 6.000 m3/h. - ATEX version possible. 6 References EQUIP- MENTS Reference Dimensions Efficiency Class ISO 16890 Filter Nominal Initial Unit Weight UxP Stock BxHxP Surface flow Pa Volume (Kg) ** 7 (MPPS E %) EN 779 (m3/h) (m2) 2250 120 (m3) MOTORS PVGV122412.4F6 305x610x292 65% M6 ePM10 70% 14 4500 120 0.06 9 1F AND PVGV242412.8F6 610x610x292 65% M6 ePM10 70% 28 2250 130 0.11 18 1 F PVGV122412.4F7 305x610x292 85% F7 ePM1 55% 14 4500 130 0.06 9 1F TURBINES PVGV242412.8F7 610x610x292 85% F7 ePM1 55% 28 2250 140 0.11 18 1 F PVGV122412.4F8 305x610x292 95% F8 ePM1 70% 14 4500 140 0.06 9 1F 8 PVGV242412.8F8 610x610x292 95% F8 ePM1 70% 28 2250 160 0.11 18 1 F PVGV122412.4F9 305x610x292 98% F9 ePM1 80% 14 4500 160 0.06 9 1F ADSOR- PVGV242412.8F9 610x610x292 98% F9 ePM1 80% 28 3000 180 0.11 18 1 F TION AND PVGV122416.4F8 305x610x400 95% F8 ePM1 70% 20 6000 180 0.08 12 1 F DESODO- PVGV242416.8F8 610x610x400 95% F8 ePM1 70% 40 0.15 22 1 F RIZATION *UxP *Stock 9 Units per box F: Manufacturer, S: Stock, SL: Limited Stock INTER- Venfilter [email protected] 107 NATONAL Tel +34 937 862 607 www.venfilter.com NORMATI- Fax +34 937 862 493 VE

0 Comfort Products INFORMA- Dieven TION Air Treatment 1 Industrial Air Treatment Systems. PRE- FILTERS Technical features 2 Type: High Efficiency Dihedral Filter. Frame: Galvanized Steel. PAINTINGS Filtering Element: Fiberglass paper. BOOTHS Separators: Thermoplastic glue beads. Sealant: Polyurethane. 3 Average Efficiency % (Em): 95% < Em. EN 779 Class: F9. COMFORT Recommended Final Pressure Pressure Drop: 450 Pa. PRODUCTS Temperature: 80ºC, in continuous service. 4 Dimensions EPA/HEPA References /ULPA Reference Dimensions Average EN 779 Filter Nominal Initial Box Weight UxP* Stock* 5 BxHxP efficiency Class Surface flow Pa Volume (kg) % (Em) (m3/h) HIGH PBF040816F9 86,5x202x400 F9 (m2) 135 130 (m3) 1.25 12 F TEMPERA- PBF040824F9 86,5x202x600 95% F9 2,2 200 130 0.07 1,4 12 F PBF062416F9 152x610x400 95% F9 3,2 1500 200 0,1 3,2 1 F TURE PHF120424F9 300x86,5x600 95% F9 6,6 300 130 0,04 2,2 9 F PHF240308F9 600x65x202 95% F9 5 200 85 0,12 1,2 12 F 6 95% 3,2 0,1 EQUIP- *UxP *Stock MENTS Units per box F: Manufacturer, S: Stock, SL: Limited Stock 7 Venfilter MOTORS 108 Tel +34 937 862 607 [email protected] AND Fax +34 937 862 493 www.venfilter.com TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products 0 Graphic INFORMA- TION Bio Bag 60 1 Function of Initial Pressure Drop vs. flow rate PRE- EN 779 M6 ePM10 70% FILTERS BB6 2 PAINTINGS BOOTHS 3 COMFORT PRODUCTS 4250 4 Bio Bag 80 EPA/HEPA /ULPA 5 Function of Initial Pressure Drop vs. flow rate HIGH TEMPERA- TURE EN 779 F7 ePM2,5 70% 6 BB7 EQUIP- MENTS 7 MOTORS AND TURBINES 4250 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 109 INTER- www.venfilter.com NATONAL NORMATI- VE

0 Comfort Products INFORMA- Bio Bag 90 TION Function of Initial Pressure Drop vs. flow rate 1 EN 779 F8 ePM2,5 70% PRE- FILTERS BB8 2 4250 PAINTINGS Bag-glass 60 BOOTHS Function of Initial Pressure Drop vs. flow rate 3 EN 779 M6 ePM2,5 50% BG6 COMFORT PRODUCTS 4250 4 Venfilter EPA/HEPA 110 Tel +34 937 862 607 [email protected] /ULPA Fax +34 937 862 493 www.venfilter.com 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products 0 Bag-glass 80 INFORMA- TION Function of Initial Pressure Drop vs. flow rate 1 EN 779 F7 ePM1 70% BG7 BG8 PRE- 4250 FILTERS Bag-glass 90 2 Function of Initial Pressure Drop vs. flow rate PAINTINGS BOOTHS EN 779 F8 ePM1 85% 3 4250 COMFORT Venfilter [email protected] PRODUCTS Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- 111 NATONAL NORMATI- VE

0 Comfort Products INFORMA- Bag-glass 90 TION Function of Initial Pressure Drop vs. flow rate 1 EN 779 F9 ePM1 85% BG9 PRE- FILTERS 2 PAINTINGS BOOTHS 3 112 4250 [email protected] www.venfilter.com COMFORT Venfilter PRODUCTS Tel +34 937 862 607 Fax +34 937 862 493 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products 0 Multiven ES A+ (SAVE ENERGY) INFORMA- TION Function of Initial Pressure Drop vs. flow rate 1 F9 EN 779 F9 ePM80 % PRE- 4250 FILTERS Minimum efficiency test 2 F9 PAINTINGS Venfilter [email protected] BOOTHS Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- 113 NATONAL NORMATI- VE

0 Comfort Products INFORMA- Multiven ES A+ (SAVE ENERGY) TION Function of Initial Pressure Drop vs. flow rate 1 F8 EN 779 F8 ePM1 65% PRE- FILTERS 2 PAINTINGS BOOTHS 3 COMFORT PRODUCTS 4 Minimum efficiency test 4250 [email protected] F8 www.venfilter.com EPA/HEPA Venfilter /ULPA 114 Tel +34 937 862 607 Fax +34 937 862 493 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products 0 Multiven ES A+ (SAVE ENERGY) INFORMA- TION Function of Initial Pressure Drop vs. flow rate 1 F7 EN 779 F7 ePM1 50% PRE- 4250 FILTERS Minmum efficiency test 2 F7 PAINTINGS Venfilter [email protected] BOOTHS Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- 115 NATONAL NORMATI- VE

0 Comfort Products INFORMA- Multiven TION Function of Initial Pressure Drop vs. flow rate 1 EN 779 F9 ePM1 80% PRE- EN 779 F8 ePM1 70% FILTERS EN 779 F7 ePM1 50% EN 779 M6 ePM10 70% 2 PAINTINGS BOOTHS 3 COMFORT PRODUCTS 4 Multiven Standard EPA/HEPA Function of Initial Pressure Drop vs. flow rate /ULPA EN 779 F9 ePM1 80% 5 EN 779 F8 ePM1 65% EN 779 F7 ePM1 50% HIGH EN 779 M6 ePM10 70% TEMPERA- 4250 TURE Venfilter 6 116 Tel +34 937 862 607 [email protected] EQUIP- Fax +34 937 862 493 www.venfilter.com MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

Comfort Products EN 779 F9 ePM1 80% 0 EN 779 F8 ePM1 65% Plastic Varipleat EN 779 F7 ePM1 50%-55% INFORMA- EN 779 M6 ePM10 60% - 65% TION Function of Initial Pressure Drop vs. flow rate VPLPL-02 1 VPLPL-04 PRE- FILTERS 2 PAINTINGS BOOTHS 3 COMFORT PRODUCTS 44250 EPA/HEPA /ULPA 5 EN 779 F9 ePM1 80% HIGH EN 779 F8 ePM1 65% TEMPERA- EN 779 F7 ePM1 50%-55% EN 779 M6 ePM10 60% - 65% TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 84250 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] INTER- www.venfilter.com 117 NATONAL NORMATI- VE

0 Comfort Products INFORMA- Varipac TION Function of Initial Pressure Drop vs. flow rate 1 VPP - WITH CLAMP PRE- FILTERS 2 EN 779 F9 ePM1 80% EN 779 F8 ePM1 65% PAINTINGS EN 779 F7 ePM1 55% BOOTHS EN 779 M6 ePM10 60% 3 COMFORT PRODUCTS 4 VP - WITHOUT CLAMP 4250 EPA/HEPA 118 EN 779 F9 /ULPA EN 779 F7 EN 779 M6 5 4250 HIGH TEMPERA- Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com TURE Fax +34 937 862 493 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Multiven HEPA INFORMA- TION Absolute Filtration / Clean Rooms Class: E and H 1 Intake, Discharge and Recirculation in ventilation systems PRE- that require high security: In Air Conditioning equipment FILTERS (Air Conditioning Units, Ventilation Chambers, etc.), Air Conditioning Systems (Hospitals, Laboratories, Museums, 2 Airports, etc.), Industrial Processes (Pharmaceutical Ind., Food Ind., Optics, Microelectronics, Veterinary Medicine, PAINTINGS Chemical Ind. and surface treatments) and as a pre-filter BOOTHS for Hepa and Ulpa filters. 3 Technical features COMFORT Type: Compact Polyhedral Rigid Bag Filter. PRODUCTS Frame: Plastic (Polypropylene). Filtering Element: Fiberglass paper. 4 Separators: Thermoplastic glue beads. Sealant: Polyurethane. EPA/HEPA MPPS Efficiency E%: 85% and 99.95% /ULPA DOP Efficiency: 95% and 99.99% EN 1822 Class: E10 and H13. 5 Recommended Final Pressure Pressure Drop: 600 Pa. Temperature: 80ºC continuous service. HIGH TEMPERA- Advantages TURE Rigid construction facilitating installation and replacement of the filter; all the components are anticorrosive and inci- 6 nerable, (they do not give off toxic gas when burnt during the incineration process at municipal waste facilities). EQUIP- MENTS References 7 Reference Model Dimensions Average Class Filter Nominal Initial Unit Weight UxP Stock BxHxP efficiency EN Surface flow (m3/h) Pa Volume (Kg) * * MOTORS MVH122412H10 MVH (MPPS E %) 1822 AND MVH202412H10 MVH 592x292x292 E10 (m2) 1700 170 (m3) 3,5 1 SL MVH242412H10 MVH 592x492x292 85% E10 9 2800 170 0,05 5 1F TURBINES 592x592x292 85% E10 15 3400 170 0,09 6 1S 85% 19 0,11 8 MVH122412H13 MVH 592x292x292 99,95% H13 9 1250 250 0,05 3,5 1 F ADSOR- MVH202412H13 MVH 592x492x292 99,95% H13 15 2100 250 0,09 5 1F TION AND MVH242412H13 MVH 592x592x292 99,95% H13 19 2500 250 0,11 6 1F DESODO- RIZATION *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock 9 Venfilter [email protected] 119 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE

0 EPA/HEPA/ULPA Certification INFORMA- Dieven Hepa TION Absolute Filtration / Clean Rooms 1 Class: H PRE- Industrial Air Treatment Systems. FILTERS Technical features 2 Type: Very High Efficiency Dihedral Filter. PAINTINGS Frame: Galvanized Steel. BOOTHS Filtering Element: Fiberglass paper. Separators: Thermoplastic glue beads. 3 Sealant: Polyurethane. MPPS Efficiency: 85%, 99.95% COMFORT EN 1822 Class: E10 and H13. PRODUCTS Recommended Final Pressure Pressure Drop: 300-500 Pa Temperature: 80ºC in continuous service. 4 Dimensions EPA/HEPA /ULPA References 5 Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit UxP Stock BxHxP (MPPS E %) EN 1822 HIGH Surface flow Pa Volume * * TEMPERA- E11 H13 (m2) (m3/h) (m3) TURE E11 PBF040824H11 PB 86,5x202x600 85% H13 3,4 210 150 0.12 12 F 6 99,95% E1 PBF040824H13 PB 86,5x202x600 H13 3.4 225 250 0.12 12 F EQUIP- 85% MENTS PHF240308H11 PH 65x202x600 99,95% 3,4 200 100 0.12 12 F 7 PHF240308H13 PH 65x202x600 85% 3.4 240 200 0.12 12 F 99,95% MOTORS PHF120424H11 PH 86,5x303x600 4.75 315 150 0.12 8 F AND PHF120424H13 PH 86,5x303x600 4,75 330 250 0.12 8 F TURBINES *UxP *Stock 8 Units per box F: Manufacturer, S: Stock, SL: Limited Stock ADSOR- 120 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA 0 Microven (MDF) INFORMA- TION Absolute Filtration / Clean Rooms Class: E 1 The Hepa semi-absolute filters are used in ventilation sys- PRE- tems such as: Air Treatment units where semi-absolute FILTERS terminal filtration is required. As a pre-filter to the abso- lute filters in Clean Rooms, Operating Theatres and Labo- 2 ratories. Industrial Processes (Microelectronics Industry, Optics, Food Industry, Fine Chemistry, etc.) PAINTINGS BOOTHS Technical features Dimensions 3 Certification Type: Semi-absolute Compact Filter. COMFORT Frame: MDF (High density wood) PRODUCTS Filtering Element: Fiberglass paper. Separators: Thermoplastic glue beads. 4 Sealant: Polyurethane. Joint: Bicomponent polyurethane liquid system. EPA/HEPA (Semi-circular expanded polyurethane) /ULPA MPPS efficiency: 85% EN 1822 Class: E10. 5 Recommended Final Pressure Pressure Drop: 600 Pa. Temperature: 80ºC in continuous service. HIGH TEMPERA- Advantages TURE - This method of V-shaped pleating guarantees the optimum geometry of the pleats and a uniform distance be- tween them, resulting in a lower pressure Pressure Drop with a higher airflow. 6 - The technology of the V-shaped pleat allows us to replace the aluminum separators and thereby eliminate the risk of leaks due to the perforations of the aluminum separators. EQUIP- - The filter is light and easy to eliminate, thanks to the new manufacturing technology. MENTS - The filter with an MDF frame can be totally incineNominal . The filter does not have any metal parts. - The total use of the filtering area, in addition to the uniform dust deposition with the new pleat shape technology, 7 leads to longer duration. - Due to the increased filtering area, the speed of the air through the filter and the resistance to flow decrease, MOTORS thereby saving energy. AND - Thanks to the uniform shape of the pleats, the airflow does not generate turbulence. - The Microven models offer more protection and reliability with the larger filtration area provided by the new pleat TURBINES shape technology; filtration efficiency is increased and an excellent cost-efficiency ratio is achieved. - The filter media is self-extinguishing glass microfiber paper (class F-1) and resistant to humidity up to 100% 8 relative humidity. ADSOR- Venfilter [email protected] 121 TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit UxP Stock 1 BxHxP (MPPS E %) EN 1822 Surface flow Pa Volume ** (m3/h) PRE- MCDMP121206H10 MCDM 305x305x150 85% E10 (m2) 475 250 (m3) 4F FILTERS MCDMP122406H10 MCDM 305x610x150 85% E10 1,77 1000 250 0,02 2F MCDMP181806H10 MCDM 457x457x150 85% E10 3,71 1160 250 0,03 2F 2 MCDMP182406H10 MCDM 457x610x150 85% E10 4,29 1570 250 0,03 1F MCDMP232306H10 MCDM 595x595x150 85% E10 5,82 2035 250 0,05 1F PAINTINGS MCDMP242406H10 MCDM 610x610x150 85% E10 7,54 2145 250 0,06 1F BOOTHS MCDMP243006H10 MCDM 762x610x150 85% E10 7,95 2715 250 0,06 1F MCDMP243606H10 MCDM 915x610x150 85% E10 10,06 3290 250 0,07 1F 3 MCDMP244806H10 MCDM 1220x610x150 85% E10 12,19 4430 250 0,09 1F MCDMP121211H10 MCDM 305x305x292 85% E10 16,43 775 250 0,12 1F COMFORT MCDMP122411H10 MCDM 305x610x292 85% E10 2,95 1625 250 0,03 1F PRODUCTS MCDMP181811H10 MCDM 457x457x292 85% E10 6,19 1880 250 0,05 1F MCDMP182411H10 MCDM 457x610x292 85% E10 7,15 2550 250 0,06 1F 4 MCDMP232311H10 MCDM 595x595x292 85% E10 9,71 3300 250 0,08 1F MCDMP242411H10 MCDM 610x610x292 85% E10 12,58 3480 250 0,11 1F EPA/HEPA MCMDP243011H10 MCDM 762x610x292 85% E10 13,26 4405 250 0,12 1F /ULPA 16,78 0,14 5 *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock HIGH TEMPERA- Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com TURE 122 Fax +34 937 862 493 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA 0 Microven INFORMA- (Galvanized) TION Absolute Filtration / Clean Rooms 1 Class: E PRE- FILTERS The Hepa semi-absolute filters are used in ventilation sys- Dimensions 2 tems such as: Air Treatment units where semi-absolute Certification terminal filtration is required. As a pre-filter to the abso- PAINTINGS lute filters in Clean Rooms, Operating Theatres and Labo- BOOTHS ratories. Industrial Processes (Microelectronics Industry, Optics, Food Industry, Fine Chemistry, etc.) 3 Technical features COMFORT PRODUCTS Type: Semi-absolute Compact Filter. Frame: Galvanized Steel. 4 Filtering Element: Glass microfiber paper. Separators: Thermoplastic glue beads. EPA/HEPA Sealant: Polyurethane. /ULPA Joint: Bicomponent polyurethane liquid system (Semi-circu- lar expanded polyurethane). 5 MPPS efficiency: 85%. EN 1822 Class: E10. HIGH Recommended Final Pressure Pressure Drop: 600 Pa. TEMPERA- Temperature: 80ºC in continuous service. TURE Advantages 6 - This method of V-shaped pleating guarantees an optimum geometry of the pleats and a uniform distance be- tween them, resulting in a lower pressure Pressure Drop with a higher airflow. EQUIP- - The technology of the V-shaped pleat allows us to replace the aluminum separators and thereby eliminate the MENTS risk of leaks due to the perforations of the aluminum separators. - The filter is light and easy to eliminate, thanks to the new manufacturing technology. 7 - The total use of the filtering area, in addition to the uniform dust deposition achieved through the new pleat shape technology, leads to longer duration. MOTORS - Due to the increased filtering area, the speed of the air through the filter and the resistance to flow decrease, AND resulting in energy saving. - Thanks to the uniform shape of the pleats, the airflow does not generate turbulence. TURBINES - The Microven products provide more protection and reliability with the larger filtration area achieved by the new pleat shape technology; filtration efficiency is improved and the cost-efficiency ratio is excellent. 8 - The filter media is self-extinguishing glass microfiber paper (class F-1) and resistant to humidity up to 100% relative humidity. ADSOR- TION AND Venfilter [email protected] 123 DESODO- Tel +34 937 862 607 www.venfilter.com RIZATION Fax +34 937 862 493 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit UxP Stock 1 BxHxP (MPPS E %) EN 1822 Surface flow Pa (m3/h) Volume * * PRE- (m2) 590 250 FILTERS 2,15 1195 250 (m3) 4,34 1345 250 2 MCGVP121206H10 MCGV 305x305x150 85% E10 4,88 1800 250 0,02 1 F MCGVP122406H10 MCGV 305x610x150 85% E10 6,54 2290 250 PAINTINGS MCGVP181806H10 MCGV 457x457x150 85% E10 9,17 2410 250 0,03 1 F BOOTHS MCGVP182406H10 MCGV 457x610x150 85% E10 9,75 3015 250 MCGVP232306H10 MCGV 595x595x150 85% E10 10,95 3625 250 0,03 1 F 3 MCGVP242406H10 MCGV 610x610x150 85% E10 13,16 4880 250 MCGVP243006H10 MCGV 762x610x150 85% E10 17,72 925 250 0,05 1 F COMFORT MCGVP243606H10 MCGV 915x610x150 85% E10 3,59 1860 250 PRODUCTS MCGVP244806H10 MCGV 1220x610x150 85% E10 7,24 2090 250 0,06 1 F MCGVP121211H10 MCGV 305x305x292 85% E10 8,15 2800 250 4 MCGVP122411H10 MCGV 305x610x292 85% E10 10,73 3560 250 0,06 1 F MCGVP181811H10 MCGV 457x457x292 85% E10 13,89 3750 250 EPA/HEPA MCGVP182411H10 MCGV 457x610x292 85% E10 14,6 4690 250 0,07 1 F /ULPA MCGVP232311H10 MCGV 595x595x292 85% E10 18,27 MCGVP242411H10 MCGV 610x610x292 85% E10 0,09 1 F 5 MCGVP243011H10 MCGV 762x610x292 85% E10 0,12 1 F HIGH TEMPERA- 0,03 4 F TURE 0,05 2 F 6 0,06 1 F EQUIP- 0,08 1 F MENTS 0,11 1 F 7 0,12 1 F MOTORS AND 0,14 1 F TURBINES *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock 8 Venfilter ADSOR- TION AND Tel +34 937 862 607 [email protected] DESODO- Fax +34 937 862 493 www.venfilter.com RIZATION 124 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Astroven (MDF) INFORMA- TION Absolute Filtration / Clean Rooms Class: H 1 The HEPA absolute filters are used for filtration of inco- PRE- ming, outgoing and recirculation air in ventilation systems FILTERS such as: Incoming Air: Clean Rooms, Operating Theatres, Laboratories, etc... Industrial Processes: Microelectro- 2 nics, food industry, optics, pharmaceutical industry, fine chemistry, etc. Treatment of Dangerous substances: As- PAINTINGS bestos, Metal dust, Bacteria, Viruses, Radioactive Parti- BOOTHS cles. 3 Technical features COMFORT Type: Compact Absolute Filter PRODUCTS Frame: MDF (High density wood) Filtering Element: Glass microfiber paper. 4 Separators: Thermoplastic glue beads. Sealant: Polyurethane. EPA/HEPA Joint: Bicomponent polyurethane liquid system. /ULPA (Semi-circular expanded polyurethane) MPPS efficiency: 99.95% and 99.995% 5 EN 1822 Class: H13 - H14. Recommended Final Pressure Pressure Drop: 600 Pa. HIGH Temperature: 80ºC in continuous service. TEMPERA- Advantages TURE - This method of V-shaped pleating guarantees an optimum geometry of the pleats and a uniform distance be- 6 tween them, resulting in a lower pressure Pressure Drop with a higher airflow. - The technology of the V-shaped pleat allows us to replace the aluminum separators and thereby eliminate the EQUIP- risk of leaks due to the perforations of the aluminum separators. MENTS - The filter is light and easy to eliminate, thanks to the new manufacturing technology. - The filter with an MDF frame can be totally incineNominal . The filter does not have any metal parts. 7 - The total use of the filtering area, in addition to the uniform dust deposition achieved through the new pleat MOTORS shape technology, leads to longer duration. AND - Due to the increased filtering area, the speed of the air through the filter and the resistance to flow decrease, thereby saving energy. TURBINES - Thanks to the uniform shape of the pleats, the airflow does not generate turbulence. - The Astroven models offer more protection and reliability with the larger filtration area provided by the new 8 pleat shape technology; filtration efficiency is increased and an excellent cost-efficiency ratio is achieved. - The filter media is self-extinguishing glass microfiber paper (class F-1) and resistant to humidity up to 100% ADSOR- relative humidity. TION AND DESODO- Venfilter [email protected] 125 RIZATION Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit Weight UxP Stock 1 BxHxP (MPPS E %) EN 1822 Surface flow (m3/h) Pa Volume (Kg) * * PRE- H13 (m2) 270 FILTERS H13 2,3 560 (m3) H13 4,82 657 2 AVDMP121206H13 AVDMP 305x305x150 99,95% H13 5,57 1145 250 0,02 4F AVDMP122406H13 AVDMP 305x610x150 99,95% H13 9,79 1200 PAINTINGS AVDMP181806H13 AVDMP 457x457x150 99,95% H13 10,32 1840 250 0,03 2F BOOTHS AVDMP232306H13 AVDMP 595x595x150 99,95% H13 15,83 375 99,95% H13 3,39 780 250 0,03 2F 3 99,95% H13 7,1 900 99,95% H13 8,21 1590 250 0,06 1F COMFORT 99,95% H13 14,42 1675 PRODUCTS AVDMP242406H13 AVDMP 610x610x150 99,95% H13 15,2 2120 250 0,06 1F AVDMP243606H13 AVDMP 915x610x150 99,95% H13 19,24 330 4 AVDMP121211H13 AVDMP 305x305x292 99,95% H13 2,83 690 250 0,09 1F AVDMP122411H13 AVDMP 305x610x292 99,95% H13 5,92 795 EPA/HEPA 99,95% H13 6,85 1475 250 0,03 4F /ULPA 99,95% H13 12,68 2260 99,95% H13 19,45 525 250 0,05 7 2S 5 99,95% H13 5,09 1095 AVDMP181811H13 AVDMP 457x457x292 99,95% H13 10,66 1265 250 0,06 1F HIGH AVDMP232311H13 AVDMP 595x595x292 99,95% H13 12,33 1715 TEMPERA- AVDMP242411H13 AVDMP 610x610x292 99,95% H13 16,75 2225 250 0,11 1F AVDMP243011H13 AVDMP 762x610x292 99,95% H13 21,67 2345 TURE AVDMPP121206H13 AVDMPP 305x305x150 99,95% H13 22,85 2970 250 0,12 13 1 S 99,95% H14 28,92 6 99,95% H14 270 250 0,14 1 SL 99,95% H14 2,30 560 EQUIP- H14 4,82 650 250 0,02 4F MENTS 99,995% H14 5,57 1200 AVDMPP122406H13 AVDMPP 305x610x150 99,995% H14 10,32 375 250 0,03 6 2F 7 AVDMPP181806H13 AVDMPP 457x457x150 99,995% H14 3,39 780 AVDMPP242406H13 AVDMPP 610x610x150 99,995% H14 7,10 900 250 0,03 2F MOTORS AVDMPP243606H13 AVDMPP 915x610x150 99,995% H14 8,21 1675 AND 99,995% H14 15,20 2120 250 0,06 12 1 F 99,995% H14 19,24 330 TURBINES 99,995% H14 2,83 690 250 0,09 1F 99,995% H14 5,92 795 8 AVDMPP121211H13 AVDMPP 305x305x292 99,995% H14 6,85 1475 250 0,03 4F AVDMPP122411H13 AVDMPP 305x610x292 99,995% H14 12,68 525 ADSOR- AVDMPP181811H13 AVDMPP 457x457x292 99,995% H14 5,09 1095 250 0,05 7.5 2 SL TION AND AVDMPP182411H13 AVDMPP 457x610x292 99,995% H14 10,66 1265 DESODO- 99,995% H14 12,33 2345 250 0,06 1F RIZATION 99,995% 22,85 2970 99,995% 28,92 250 0,08 1F 9 99,995% AVDMPP232311H13 AVDMPP 595x595x292 99,995% 250 0,11 1F INTER- AVDMPP242411H13 AVDMPP 610x610x292 NATONAL AVDMPP243011H13 AVDMPP 762x610x292 250 0,12 14 1 SL NORMATI- 250 0,14 1F VE AVDMP121206H14 AVDMP 305x305x150 270 0,02 4F AVDMP122406H14 AVDMP 305x610x150 AVDMP181806H14 AVDMP 457x457x150 270 0,03 2F 270 0,03 1F AVDMP242406H14 AVDMP 610x610x150 270 0,06 1F AVDMP121211H14 AVDMP 305x305x292 AVDMP122411H14 AVDMP 305x610x292 270 0,03 4F AVDMP181811H14 AVDMP 457x457x292 270 0,05 2F 270 0,06 1F AVDMP242411H14 AVDMP 610x610x292 270 0,12 1F AVDMP243011H14 AVDMP 762x610x292 AVDMPP121206H14 AVDMPP 305x305x150 270 0,14 1F AVDMPP122406H14 AVDMPP 305x610x150 AVDMPP181806H14 AVDMPP 457x457x150 270 0,02 4F 270 0,03 2F 270 0,03 1F AVDMPP242406H14 AVDMPP 610x610x150 270 0,06 1F AVDMPP121211H14 AVDMPP 305x305x292 AVDMPP122411H14 AVDMPP 305x610x292 270 0,03 4F AVDMPP181811H14 AVDMPP 457x457x292 270 0,05 2F 270 0,06 1F AVDMPP242411H14 AVDMPP 610x610x292 270 0,12 1F AVDMPP243011H14 AVDMPP 762x610x292 270 0,14 1F *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock Venfilter Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 126

EPA/HEPA/ULPA Dimensions 0 Astroven (MDF) ATEX INFORMA- TION Absolute Filtration / Clean Rooms Class: H 1 The Astroven ATEX, is a Hepa filter suitable for filtering particles PRE- in the air such as viruses, germs, toxic dust or aerosols. For appli- FILTERS cations in special air conditioning and ventilation systems for food, chemical, pharmaceutical, etc. Which have to meet the deman- 2 ding requirements of explosive atmospheres. In areas with potentially explosive atmospheres (those that in at- PAINTINGS mospheric conditions are a mixture of air and hazardous substan- BOOTHS ces in the form of gases, vapors, mists or dusts and, in which after ignition occurs, combustion spreads to the whole of the unbur- 3 ned mixture) the filters are conductors of electricity, prepared by means of a connection cable for electrostatic discharge, comply COMFORT with the European ATEX directive for products used in explosive PRODUCTS atmospheres. Technical features Certification 4 Type: Very High Efficient Absolute Compact Filter. EPA/HEPA Frame: MDF (High density wood). /ULPA Filter Element: Fiberglass paper. Separators: Wavy Aluminum. 5 Sealant: Polyurethane. Seal: Neoprene flat profile seal. HIGH MPPS efficiency: 99.95% and 99.995%. TEMPERA- EN 1822 Class: H13 and H14. Recommended Final Pressure Drop: 600 Pa. TURE Temperature: 75ºC in continuous service. 6 References EQUIP- Reference Dimensions Efficiency EN Filtrant Nominal Initial Unit UxP Stock MENTS BxHxP Filtering 1822 Surface Flow AVDM122411H13ATEX Surface Class (m3/h) Pa Volume * * 7 AVDM242411H13ATEX (MPPS E %) (m2) AVDM122411H14ATEX (m3) MOTORS AVDM242411H14ATEX AND 305x610x292 99,95 H13 11 1250 250 0,05 1 F TURBINES 610x610x292 99,95 H13 22 2500 250 0,12 1 F 8 305x610x292 99,995 H14 11 1100 250 0,05 1 F ADSOR- 610x610x292 99,995 H14 22 2200 250 0,12 1 F TION AND DESODO- *UxP *Stock RIZATION Units per box F: Manufacturer, S: Stock, SL: Limited Stock 9 Venfilter [email protected] 127 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE

0 EPA/HEPA/ULPA Dimensions Certification INFORMA- Astroven (Galvanized) TION Absolute Filtration / Clean Rooms 1 Class: H PRE- The HEPA absolute filters are used for filtration of inco- FILTERS ming, outgoing and recirculation air in ventilation systems such as: Incoming Air: Clean Rooms, Operating Theatres, 2 Laboratories, etc. Industrial Processes: Microelectronics, food industry, optics, pharmaceutical industry, fine che- PAINTINGS mistry, etc. Treatment of Dangerous substances: Asbes- BOOTHS tos, Metal dust, Bacteria, Viruses, Radioactive Particles. 3 Technical features COMFORT Type: Compact Very High Efficiency Absolute Filter PRODUCTS Frame: Galvanized Steel. Filtering Element: Glass microfiber paper. 4 Separators: Thermoplastic glue beads. Sealant: Polyurethane. EPA/HEPA Joint: Bicomponent polyurethane liquid system. (Semi-circu- /ULPA lar expanded polyurethane) MPPS Efficiency: 99.95% and 99.995% 5 EN 1822 Class: H13 and H14. Recommended Final Pressure Pressure Drop: 600 Pa. HIGH Temperature: 80ºC in continuous service. TEMPERA- Advantages TURE - This method of V-shaped pleating guarantees an optimum geometry of the pleats and a uniform distance be- 6 tween them, resulting in a lower pressure Pressure Drop with a higher airflow. - The technology of the V-shaped pleat allows us to replace the aluminum separators and thereby eliminate the EQUIP- risk of leaks due to the perforations of the aluminum separators. MENTS - The filter is light and easy to eliminate, thanks to the new manufacturing technology. - The total use of the filtering area, in addition to the uniform dust deposition achieved through the new pleat 7 shape technology, leads to longer duration. - Due to the increased filtering area, the speed of the air through the filter and the resistance to flow decrease, MOTORS thereby saving energy. AND - Thanks to the uniform shape of the pleats, the airflow does not generate turbulence. - The Astroven models offer more protection and reliability with the larger filtration area provided by the new TURBINES pleat shape technology; filtration efficiency is increased and an excellent cost-efficiency ratio is achieved. - The filter media is self-extinguishing glass microfiber paper (class F-1) and resistant to humidity up to 100% 8 relative humidity. ADSOR- Venfilter TION AND DESODO- Tel +34 937 862 607 [email protected] RIZATION Fax +34 937 862 493 www.venfilter.com 128 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA 0 References INFORMA- TION Reference Dimensions Efficiency Class Filter Nominal Initial Pa Unit Weight UxP Stock BxHxP (MPPS E %) EN 1822 Surface flow Volume (Kg) * * 1 (m3/h) (m2) (m3) 4 F PRE- 2,8 2 F FILTERS AVGVP121206H13 305x305x150 99,95% H13 5,65 325 250 0,02 2 F AVGVP122406H13 305x610x150 99,95% H13 6,36 655 250 0,03 1 F 2 AVGVP181806H13 457x457x150 99,95% H13 8,52 1 F AVGVP182406H13 457x610x150 99,95% H13 10,85 740 250 0,03 1 SL PAINTINGS AVGVP232306H13 595x595x150 99,95% H13 11,4 990 250 0,05 1 F BOOTHS AVGVP242406H13 610x610x150 99,95% H13 17,15 1260 250 0,06 1 F AVGVP243606H13 915x610x150 99,95% H13 23,08 1320 250 0,06 9 F 3 AVGVP244806H13 1220x610x150 99,95% H13 1,5 1990 250 0,09 4 F AVGVPP080806H13 203x203x150 99,95% H13 3,44 2675 250 0,12 2 F COMFORT AVGVPP121206H13 305x305x150 99,95% H13 175 250 0,01 1 F PRODUCTS 6,93 400 250 0,02 1 F AVGVPP122406H13 305x610x150 99,95% H13 7,8 1 F 4 AVGVPP181806H13 457x457x150 99,95% H13 10,44 805 250 0,03 6 1 F AVGVPP182406H13 457x610x150 99,95% H13 13,97 910 1 F EPA/HEPA AVGVPP242406H13 610x610x150 99,95% H13 21 1215 250 0,03 /ULPA AVGVPP243606H13 915x610x150 99,95% H13 28,05 1625 4 F AVGVPP244806H13 1220x610x150 99,95% H13 2445 250 0,05 2 SL 5 4,12 3265 1 F AVGVP121211H13 305x305x292 99,95% H13 8,3 250 0,06 12 1 F HIGH AVGVP122411H13 305x610x292 99,95% H13 9,35 1 F TEMPERA- AVGVP181811H13 457x457x292 99,95% H13 12,52 250 0,09 1 S AVGVP182411H13 457x610x292 99,95% H13 15,93 1 F TURE AVGVP232311H13 595x595x292 99,95% H13 16,75 250 0,12 4 F AVGVP242411H13 610x610x292 99,95% H13 20,96 2 SL 6 AVGVP243011H13 762x610x292 99,95% H13 6,19 445 250 0,03 1 F AVGVPP121211H13 305x305x292 99,95% H13 12,48 895 250 0,05 1 F EQUIP- AVGVPP122411H13 305x610x292 99,95% H13 1 F MENTS 14,05 1005 250 0,06 7 1 SL AVGVPP181811H13 457x457x292 99,95% H13 18,81 1350 250 0,08 1 F 7 AVGVPP182411H13 457x610x292 99,95% H13 23,94 1715 250 0,11 4 F AVGVPP232311H13 595x595x292 99,95% H13 25,17 1805 250 0,12 2 F MOTORS AVGVPP242411H13 610x610x292 99,95% H13 31,5 2260 250 0,14 1 F AND AVGVPP243011H13 762x610x292 99,95% H13 660 250 0,03 1 F AVGVP121206H14 305x305x150 99,995% H14 2,8 1330 250 0,05 4 F TURBINES AVGVP122406H14 305x610x150 99,995% H14 5,65 2 F AVGVP181806H14 457x457x150 99,995% H14 6,36 1495 250 0,06 1 F 8 AVGVP242406H14 610x610x150 99,995% H14 11,4 2000 250 0,08 1 F AVGVPP121206H14 305x305x150 99,995% H14 3,44 2550 250 0,11 4 F ADSOR- AVGVPP122406H14 305x610x150 99,995% H14 6,93 2680 250 0,12 13 2 F TION AND AVGVPP181806H14 457x457x150 99,995% H14 7,8 3355 250 0,14 1 F DESODO- AVGVPP242406H14 610x610x150 99,995% H14 13,97 325 270 0,02 1 F RIZATION AVGVP121211H14 305x305x292 99,995% H14 4,12 655 270 0,03 1 F AVGVP122411H14 305x610x292 99,995% H14 8,3 4 F 9 AVGVP181811H14 457x457x292 99,995% H14 9,35 740 270 0,03 2 F AVGVP242411H14 610x610x292 99,995% H14 16,75 1 F INTER- AVGVP243011H14 762x610x292 99,995% H14 20,96 1320 270 0,06 1 F NATONAL AVGVPP121211H14 305x305x292 99,995% H14 6,19 400 270 0,02 1 F NORMATI- AVGVPP122411H14 305x610x292 99,995% H14 12,48 805 270 0,03 AVGVPP181811H14 457x457x292 99,995% H14 14,05 910 270 0,03 VE AVGVPP242411H14 610x610x292 99,995% H14 25,17 1625 270 0,06 AVGVPP243011H14 762x610x292 99,995% H14 31,5 445 270 0,03 895 270 0,05 1005 270 0,06 1805 270 0,12 2260 270 0,14 660 270 0,03 1330 270 0,05 1495 270 0,06 2680 270 0,12 3355/270 270 0,14 *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock Venfilter [email protected] 129 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493

0 EPA/HEPA/ULPA Dimensions INFORMA- Astroven TION (Galvanized) ATEX 1 Absolute Filtration / Clean Rooms Class: H PRE- FILTERS The Astroven ATEX, is a Hepa filter suitable for filtering particles in the air such as viruses, germs, toxic dust or aerosols. For appli- 2 cations in special air conditioning and ventilation systems for food, chemical, pharmaceutical, etc. Which have to meet the demanding PAINTINGS requirements of explosive atmospheres. BOOTHS In areas with potentially explosive atmospheres (those that in at- mospheric conditions are a mixture of air and hazardous subs- 3 tances in the form of gases, vapors, mists or dusts and in which after ignition occurs, combustion spreads to the whole of the un- COMFORT burned mixture) the filters are conductors of electricity, prepared PRODUCTS by means of a connection cable for electrostatic discharge, comply with the European ATEX directive for products used in explosive atmospheres. 4 Technical features Certification EPA/HEPA Type: Very High Efficient Absolute Compact Filter. /ULPA Frame: Galvanized Steel. Filter Element: Fiberglass paper. 5 Separators: wavy aluminum. Sealant: Polyurethane. HIGH Seal: Neoprene flat profile seal. TEMPERA- MPPS efficiency: 99.95% and 99.995%. EN 1822 Class : H13 and H14. TURE Recommended Final Pressure Drop: 600 Pa. Temperature: 75ºC in continuous service. 6 References Dimensions Efficiency EN Filtrant Nominal Initial Unit UxP Stock EQUIP- BxHxP Filtering 1822 Surface Flow MENTS Reference Surface Class (m3/h) Pa Volume * * (MPPS E %) (m2) 7 AVGV122411H13ATEX (m3) AVGV242411H13ATEX MOTORS AVGV122411H14ATEX 305x610x292 99,95 H13 11 1250 250 0,05 1 F AND AVGV242411H14ATEX 610x610x292 99,95 H13 22 2500 250 0,12 1 F TURBINES 130 305x610x292 99,995 H14 11 1100 250 0,05 1 F 8 610x610x292 99,995 H14 22 2200 250 0,12 1 F ADSOR- TION AND *UxP *Stock DESODO- Units per box RIZATION F: Manufacturer, S: Stock, SL: Limited Stock [email protected] 9 Venfilter www.venfilter.com Tel +34 937 862 607 INTER- Fax +34 937 862 493 NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Poliven (Galvanized) INFORMA- TION Absolute Filtration / Clean Rooms Class: H and U 1 The HEPA absolute filters are used for filtration of inco- PRE- ming, outgoing and recirculation air in ventilation systems FILTERS such as: Incoming Air: Clean Rooms, Operating Theatres, Laboratories, etc. Industrial Processes: Microelectronics, 2 food industry, optics, pharmaceutical industry, fine che- mistry, etc. Treatment of Dangerous substances: Asbes- PAINTINGS tos, Metal dust, Bacteria, Viruses, Radioactive Particles. BOOTHS Technical features Certification 3 Type: Compact Polyhedral Absolute Filter with Very High COMFORT Efficiency and Large Flow. PRODUCTS Frame: Galvanized Steel with handle Filtering Element: Glass microfiber paper. 4 Separators: Thermoplastic glue beads. Sealant: Polyurethane. EPA/HEPA Joint: Bicomponent polyurethane liquid system (Semi-circu- /ULPA lar expanded polyurethane). MPPS efficiency: 85%, 99.95% and 99.995% 5 EN 1822 Class: E10, H13 and H14. Recommended Final Pressure Pressure Drop: 600 Pa. HIGH Temperature: 80ºC in continuous service. TEMPERA- Advantages TURE - In new installations is required to be a lower number of filters to filter the same volume of air in the comparison 6 of the HEPA filters of the same dimensions. - High Nominal flow for a low-pressure Pressure Drop. EQUIP- - Drastic weight reduction with respect to the pre-existing filters. MENTS - Filters totally interchangeable with the minipleat aluminum separator filters which have Galvanized steel or wooden frames. 7 - ATEX version possible. MOTORS Venfilter [email protected] 131 AND Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit Weight UxP Stock 1 BxHxP (MPPS E %) EN 1822 Surface flow Pa Volume (kg) * * (m3/h) PRE- PVGV112312.4H10 PVGV-HP 290x595x292 85% E10 (m2) 1700 250 (m3) 14 1 F FILTERS PVGV122412.4H10 PVGV-HP 305x610x292 85% E10 14 2000 250 0,05 14 1 F PVGV242412.6H10 PVGV-HP 610x610x292 85% E10 16 4000 250 0,05 20 1 F 2 PVGV232312.10H10 PVGV-HP 595x595x292 85% E10 24 4200 250 0,12 23 1 F PVGV242412.10H10 PVGV-HP 610x610x292 85% E10 35 5000 250 0,11 23 1 F PAINTINGS PVGV243012.12H10 PVGV-HP 762x610x292 85% E10 38 6200 250 0,12 30 1 F BOOTHS PVGV112312.4H13 PVGV-HP 290x595x292 99,95% H13 45 1500 280 0,14 14 2 F PVGV122412.4H13 PVGV-HP 305x610x292 99,95% H13 15 1700 280 0,05 14 2 S 3 PVGV242412.8H13 PVGV-HP 610x610x292 99,95% H13 16 3400 280 0,05 21 1 F PVGV232312.10H13 PVGV-HP 595x595x292 99,95% H13 32 3800 280 0,12 23 1 S COMFORT PVGV242412.10H13 PVGV-HP 610x610x292 99,95% H13 38 4000 280 0,12 23 1 S PRODUCTS PVGV243012.12H13 PVGV-HP 762x610x292 99,95% H13 40 5000 280 0,12 30 1 F PVGV122412.4H14 PVGV-HP 305x610x292 99,995% H14 45 1200 280 0,14 14 2 F PVGV242412.10H14 PVGV-HP 610x610x292 99,995% H14 16 3200 280 0,05 23 1 S 40 0,12 4 *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- 132 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Poliven (Plastic) INFORMA- TION Absolute Filtration / Clean Rooms Class: E and H 1 The HEPA absolute filters are used for filtration of incoming, PRE- outgoing and recirculation air in ventilation systems such as: FILTERS Incoming Air: Clean Rooms, Operating Theatres, Laboratories, etc. Industrial Processes: Microelectronics, food industry, op- 2 tics, pharmaceutical industry, fine chemistry, etc. Treatment of Dangerous substances: Asbestos, Metal dust, Bacteria, Vi- PAINTINGS ruses, Radioactive Particles. BOOTHS Technical features 3 Type: Compact Polyhedral Absolute Filter with Very High COMFORT Efficiency and Large Flow. PRODUCTS Frame: Polyethylene with forming for extraction. Filtering Element: Glass microfiber paper. 4 Separators: Thermoplastic glue beads. Sealant: Polyurethane. EPA/HEPA Joint: Bicomponent polyurethane liquid system. /ULPA (Semi-circular expanded polyurethane) MPPS efficiency: 85%, 99.95% and 99.995% 5 EN 1822 Class: E10, H13 and H14. Recommended Final Pressure Pressure Drop: 600 Pa. HIGH Temperature: 80ºC in continuous service. TEMPERA- Advantages TURE - Rigid polyethylene construction facilitating installation and replacement of the filter; all the components are 6 Anticorrosive and incinerable, (they do not give off toxic gas when burnt during the incineration process at mu- nicipal waste facilities). EQUIP- - IN NEW INSTALLATIONS: fewer filters are required to filter the same volume of air, compared with HEPA fil- MENTS ters of the same size. - High Nominal flow for a low-pressure Pressure Drop. 7 - Lower energy consumption (increases savings on power us). - Filters totally interchangeable with the minipleat aluminum separator filters which have Galvanized steel or MOTORS wooden frames. AND - Suitable for food industry. TURBINES Venfilter [email protected] 133 Tel +34 937 862 607 www.venfilter.com 8 Fax +34 937 862 493 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References Model Dimensions Efficiency Class Filter Nominal Initial Unit UxP Stock TION BxHxP Surface Reference PV-HP (MPPS E %) EN 1822 flow Pa Volume * * 1 PV-HP 305x610x292 (m2) PV122412.4H10 PV-HP 610x610x292 16 (m3/h) (m3) PRE- PV242412.6H10 PV-HP 610x610x292 24 FILTERS PV242412.10H10 PV-HP 305x610x292 85% E10 38 2000 250 0,05 1 F PV122412.4H13 PV-HP 610x610x292 85% E10 16 2 PV242412.8H13 PV-HP 610x610x292 85% E10 32 4000 250 0,12 1 F PV242412.10H13 PV-HP 305x610x292 99,95% H13 40 PAINTINGS PV122412.4H14 610x610x292 99,95% H13 16 5000 250 0,12 1 F BOOTHS PV242412.10H14 99,95% H13 40 99,995% H14 1700 280 0,05 2 SL 3 99,995% H14 3400 280 0,12 1 F COMFORT PRODUCTS 4000 280 0,12 1 SL 1200 280 0,05 2 F 3200 280 0,12 1 F *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock 4 134 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com EPA/HEPA Fax +34 937 862 493 /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Laminarven 66 mm INFORMA- TION Absolute Filtration / Clean Rooms Class: E, H and U 1 Terminal or air return filtration in clean rooms and lami- PRE- nar flow cabins. FILTERS Technical features 2 Type: Laminar Flow HEPA/ULPA Panel. PAINTINGS Frame: Extruded and anodized aluminum profile. BOOTHS Filtering Element: Glass microfiber paper. Separators: Thermoplastic glue beads. 3 Sealant: Polyurethane. Protective grille: Steel grille painted on both sides with COMFORT white epoxy. PRODUCTS Joint: Bicomponent polyurethane liquid system. (Continuous semi-circular expanded polyurethane.) Certification 4 OPTIMAL PRESSURE FOR FILTER FIXING: 35KPa MPPS Efficiency: 85%, 99.95% and 99.995% Photo detail joint. EPA/HEPA EN 1822 Class: E10, H13 and H14. 135 /ULPA Recommended Final Pressure Drop: 600 Pa. Temperature: 80ºC in continuous service. 5 Advantages HIGH TEMPERA- -Protection on both GRID faces. - 100% scanned, in accordance with Regulation EN 1822-4. TURE - DOUBLE LABELLING-ATTACHED. - Our production quality control procedures priorities filter 6 levels and Initial Pas. EQUIP- - All out filters are subjected to an individual scanning test MENTS in order to guarantee optimum performance. 7 - The individual filter test on each and every one of our filters consists of monitoring nominal flow rates in order to deter- MOTORS mine pressure Pressure Drop and a scan made with a mono- AND disperse aerosol (DESH) in accordance with Regulation EN 1822 (Annexed 4) in order to verify the absence of localized TURBINES leaks and to determine the effective value of overall efficacy with respect to maximum penetration particle size (MPPS). 8 - Once these tests have been carried out, each filter is given a control label, which indicates its serial number, its per- ADSOR- formance and Pressure Drop, with respect to the flow test TION AND applied. DESODO- - All filters come with an individual test certificate. RIZATION - Suitable for food industry. - ATEX version possible. 9 Venfilter [email protected] INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Class Filter Nominal Initial Unit Weight UxP Stock 1 BxHxP EN 1822 Surface flow Pa Volume LV122466H10 LV66 (m3/h) (Kg) * * PRE- LV242466H10 LV66 (m2) 300 50 (m3) FILTERS LV243666H10 LV66 610x305x66 E10 5,2 600 50 0,01 2.5 1 F LV244866H10 LV66 610x610x66 E10 10,25 900 50 0,03 7 1F 2 LV080866H14 LV66 915x610x66 E10 15,46 1200 50 0,04 10 1 F LV121266H14 LV66 1220x610x66 E10 20,66 70 120 0,05 12 1 F PAINTINGS LV122466H14 LV66 203x203x66 H14 1,2 150 120 0,003 2 1F BOOTHS LV123066H14 LV66 305x305x66 H14 2,66 300 120 0,006 2,5 1 S LV123666H14 LV66 610x305x66 H14 5,2 380 120 0,01 4 1S 3 LV181866H14 LV66 762x305x66 H14 6,4 450 120 0,02 5 1 SL LV182466H14 LV66 915x305x66 H14 7,73 340 120 0,02 7,5 1 F COMFORT LV242466H14 LV66 457x457x66 H14 6 450 120 0,01 5 1S PRODUCTS LV243066H14 LV66 457x610x66 H14 7,73 600 120 0,02 6 1 SL LV243666H14 LV66 610x610x66 H14 10,25 750 120 0,03 7 1S 4 LV244866H14 LV66 762x610x66 H14 12,93 900 120 0,03 8,5 1 SL LV246066H14 LV66 915x610x66 H14 15,46 1200 120 0,04 10 1 S EPA/HEPA LV247266H14 LV66 1220x610x66 H14 20,66 1500 120 0,05 12 1 S /ULPA LV303066H14 LV66 1525x610x66 H14 26 1800 120 0,06 16 1 SL LV303666H14 LV66 1830x610x66 H14 30,66 940 120 0,08 19 1 SL 5 LV304866H14 LV66 762x762x66 H14 16 1130 120 0,04 5 1 SL LV306066H14 LV66 915x762x66 H14 19,2 1500 120 0,05 9 1F HIGH LV307266H14 LV66 1220x762x66 H14 25,8 1880 120 0,06 11 1 SL TEMPERA- LV363666H14 LV66 1525x762x66 H14 32 2260 120 0,08 16 1 SL LV364866H14 LV66 1830x762x66 H14 38,8 1350 120 0,10 19 1 SL TURE LV366066H14 LV66 915x915x66 H14 23,03 1800 120 0,06 14 1 SL LV367266H14 LV66 1220x915x66 H14 30,9 2250 120 0,08 19 1 SL 6 LV121266U15 LV66 1525x915x66 H14 38,4 2700 120 0,10 23 1 SL LV122466U15 LV66 1830x915x66 H14 46,3 150 140 0,12 28 1 F EQUIP- LV242466U15 LV66 305x305x66 U15 2,8 300 140 0,006 2,5 8 F MENTS LV243066U15 LV66 610x305x66 U15 5,5 600 140 0,01 4 4F LV243666U15 LV66 610x610x66 U15 11 750 140 0,03 7 2F 7 LV244866U15 LV66 762x610x66 U15 14 900 140 0,03 8,5 4 F 915x610x66 U15 17 1200 140 0,04 10 2 F MOTORS 1220x610x66 U15 22,5 0,05 12 1 F AND *UxP *Stock TURBINES Units per box F: Manufacturer, S: Stock, SL: Limited Stock 8 Venfilter ADSOR- Tel +34 937 862 607 [email protected] TION AND Fax +34 937 862 493 www.venfilter.com DESODO- 136 RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Laminarven 78 mm INFORMA- TION Absolute Filtration / Clean Rooms Class: E, H and U 1 Terminal or air return filtration in clean rooms and lami- PRE- nar flow cabins. FILTERS Technical features 2 Type: Laminar Flow HEPA Panel. PAINTINGS Frame: Extruded and anodized aluminum profile. BOOTHS Filtering Element: Glass microfiber paper. Separators: Thermoplastic glue beads. 3 Sealant: Polyurethane. Protective grille: Steel grille painted on both sides with COMFORT white epoxy. PRODUCTS Joint: Gasket with plane profile of neoprene. OPTIMAL PRESSURE FOR FILTER FIXING: 70KPa 4 MPPS Efficiency: 85%, 99.95% and 99.995% EN 1822 Class: E10, H13 and H14. EPA/HEPA Recommended Final Pressure Pressure Drop: 600 Pa. /ULPA Temperature: 80ºC in continuous service. 5 Advantages HIGH - Extruded anodized aluminum frame, avoids particle TEMPERA- detachment present in agglomeNominal frames or TURE similar constructions materials. - Gird protection at the air outlet and inlet to prevent 6 filter surfaces breakages. - This method of V-shaped pleating guarantees the opti- EQUIP- mal geometry characteristics for the folds and a MENTS uniform distance between them, resulting in a reduced 7 Pressure Drop with greater airflow. - 100% scanned in accordance with regulation EN 1822-4. MOTORS - DOUBLE LABELLING ATTACHED. AND - Suitable for food industry. - ATEX version possible. TURBINES 8 Photo detail joint: ADSOR- Plane of neoprene TION AND DESODO- Venfilter RIZATION Tel +34 937 862 607 Fax +34 937 862 493 9 [email protected] 137 INTER- www.venfilter.com NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency EN 1822 Filter Nominal Maximum Unit Weight UxP Stock 1 BxHxP (MPPS E%) Class Surface Flow Nominal Volume (kg) * * LV121278H13 LV78 0.45 PRE- LV122478H13 LV78 (m2) Flow (m3) 1.4 1 SL FILTERS LV181878H13 LV78 (m3/h)/Pa (m3/h)/Pa 2,75 1 F LV212178H13 LV78 305x305x78 99,95 H13 2,5 125/95 250/180 0,007 3.10 1 SL 2 LV222278H13 LV78 610x305x78 99,95 H13 5,5 300/95 540/180 0,01 4,8 1 F LV242478H13 LV78 457x457x78 99,95 H13 6 340/95 600/180 0,02 1 F PAINTINGS LV243678H13 LV78 535x535x78 99,95 H13 8,50 460/95 850/180 0,02 5 1 SL BOOTHS LV244878H13 LV78 575x575x78 99,95 H13 9,9 535/95 970/180 0,03 5.5 1 F LV121278H14 LV78 610x610x78 99,95 H13 11 600/95 1100/180 0,03 8,25 1 F 3 LV122478H14 LV78 915x610x78 99,95 H13 16,5 900/95 1400/180 0,04 11 1 F LV181878H14 LV78 1220x610x78 99,95 H13 22 1200/95 2200/180 0,06 1.4 1 F COMFORT LV212178H14 LV78 305x305x78 99,995 H14 2,5 125/120 250/230 0,007 2,75 1 SL PRODUCTS LV222278H14 LV78 610x305x78 99,995 H14 5,5 300/120 540/230 0,01 3.10 1 F LV242478H14 LV78 457x457x78 99,995 H14 6 340/120 600/230 0,02 4,8 1 F 4 LV243678H14 LV78 535x535x78 99,995 H14 8,50 460/120 850/230 0,02 5 1 SL LV244878H14 LV78 575x575x78 99,995 H14 9,9 535/120 970/230 0,03 5.5 1 F 610x610x78 99,995 H14 11 600/120 1100/230 0,03 8,25 1 F 915x610x78 99,995 H14 16,5 900/120 1400/230 0,04 11 1220x610x78 99,995 H14 22 2200/230 0,06 1200/120 EPA/HEPA *UxP *Stock /ULPA Units per box F: Manufacturer, S: Stock, SL: Limited Stock 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- 138 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Laminarven Plus INFORMA- 90/110 mm TION Absolute Filtration / Clean Rooms 1 Class: E, H and U PRE- Terminal or air return filtration in clean rooms and lami- FILTERS nar flow cabins. 2 Technical features PAINTINGS Type: Laminar Flow HEPA Panel. BOOTHS Frame: Extruded and anodized aluminum profile. Filtering Element: Glass microfiber paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Protective grille: Steel grille painted on both sides with PRODUCTS white epoxy. Joint: Bicomponent polyurethane liquid system. (Conti- 4 nuous semi-circular expanded polyurethane.) OPTIMAL PRESSURE FOR FILTER FIXING: 35KPa EPA/HEPA MPPS Efficiency: 85%, 99.95% and 99.995% /ULPA EN 1822 Class: E10, H13 and H14. Recommended Final Pressure Pressure Drop: 600 Pa. 5 Advantages HIGH TEMPERA- - This method of V-shaped pleationg guarantees optimal geome- try characteristics for the folds and a uniform distance between TURE them, resulting in a reduced Pressure Drop with greater airflow. - V-shaped pleated technology means that aluminum separator 6 con be replaced, therefore eliminating the risk of leaks due to perforations in the aluminum separators. EQUIP- - The total use of the filter surface, in addition to an even dust de- MENTS posit with the new pleat technology means longer-lasting equi- pement. 7 - Protection on both grid faces. - 100% sacneed, in accordance with regulation EN 1822-4. MOTORS - DOUBLE LABELLING ATTACHED. AND - Suitable for food industry. TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 139 INTER- www.venfilter.com NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency EN 1822 Filter Nominal Maximum Unit Weight UxP S 1 BxHxP (MPPS E%) Class Surface Flow LV122490H14 LV90 0.45 Nominal volume (Kg) ** PRE- LV242490H14 LV90 (m2) FILTERS LV243690H14 LV90 (m3/h)/Pa Flow (m3) LV244890H14 LV90 300/90 2 LV1224110H14 LV110 600/90 (m3/h)/Pa LV2424110H14 LV110 900/90 PAINTINGS LV2448110H14 LV90 610x305x90 99,995 H14 7,15 1200/90 800/250 0.01 3 1F BOOTHS LV122490U15 LV90 610x610x90 99,995 H14 14,3 300/85 LV242490U15 LV90 915x610x90 99,995 H14 21,45 600/85 1600/250 0.03 7 1F 3 LV244890U15 LV90 1220x610x90 99,995 H14 28,6 1200/85 1800/250 0,05 9 1F LV1224110U15 LV110 610x305x110 99,995 H14 9,50 300/120 COMFORT LV2424110U15 LV110 610x610x110 99,995 H14 19 600/120 3400/250 0,07 12 1F PRODUCTS LV2448110U15 LV110 1120x610x110 99,995 H14 38 610x305x90 99,9995 U15 7,15 1200/120 900/250 0,02 5 1F 4 610x610x90 99,9995 U15 14,3 300/100 1220x610x90 99,9995 U15 29 1800/250 0,04 10 1F EPA/HEPA 610x305x110 99,9995 U15 9,50 600/100 /ULPA 610x610x110 99,9995 U15 19 1200/100 3600/250 0,08 36 1F 1220x610x110 99,9995 U15 36 5 750/300 0,02 6 1F HIGH 1500/300 0,03 12 1F TEMPERA- 3000/300 0,07 25 1F TURE 900/300 0.02 9 1F 6 1800/300 0.04 18 1F EQUIP- 3600/300 0.08 36 1F MENTS *UxP *Stock 7 Units per box F: Manufacturer, S: Stock, SL: Limited Stock MOTORS Venfilter AND Tel +34 937 862 607 [email protected] TURBINES Fax +34 937 862 493 www.venfilter.com 140 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Laminarven Gel INFORMA- TION Absolute Filtration / Clean Rooms Class: H and U 1 Terminal filtration in clean rooms and laminar flow PRE- cabins. FILTERS Technical features 2 Type: Laminar flow HEPA panel. PAINTINGS Frame: Extruded and anodized aluminum profile. BOOTHS Material: Glass microfiber filter paper. Separators: Hot melt beads. 3 Sealant: Polyurethane. Protective grid: Steel grid painted on both sides in white COMFORT epoxy. PRODUCTS Joint: Gel MPPS Efficiency: 99,995% and 99,9995% 4 EN 1822 Class: H14 and U15. Recommended Final Pressure Pressure Drop: 600 Pa. EPA/HEPA Temperature: 80ºC in continuous service. /ULPA Advantages 5 - The new gek seal prevents those leaks that occur in neoprene HIGH or liquid filters, which lose elasticity over time and so copromi- TEMPERA- se the sealing capacity of terminal diffusers and filters. - Grid protection at the air inlet and outlet to avoid breakages on TURE the filter surface. - 100% scanned, in accordance with regulations EN 1822-4. 6 - DOUBLE LABELLING ATTACHED. - Suitable for food industry. EQUIP- MENTS 7 MOTORS AND TURBINES Gel Seal detail 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 141 INTER- www.venfilter.com NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency EN 1882 Filter Nominal Maximum Unit Weight UxP S 1 BxHxP (MPPS E%) Class Surface Flow 0.45 Nominal volume (Kg) ** PRE- (m2) FILTERS (m3/h)/Pa Flow (m3) 2 (m3/h)/Pa PAINTINGS LVG121280H14 LVGEL 305x305x80 99,995 H14 2,5 125/120 225/185 0.007 1,4 1F BOOTHS LVG122480H14 LVGEL 610x305x80 99,995 1F LVG181880H14 LVGEL 457x457x80 99,995 H14 5,5 300/120 500/185 0.01 2,75 1F 3 LVG242480H14 LVGEL 610x610x80 99,995 1F LVG243680H14 LVGEL 915x610x80 99,995 H14 6 340/120 450/185 0.02 3,10 1F COMFORT LVG244880H14 LVGEL 1220x610x80 99,995 1F PRODUCTS H14 11 600/120 900/185 0.03 5,5 4 H14 16,5 900/120 1500/185 0.04 8,25 EPA/HEPA H14 22 1200/120 2000/185 0.06 11 /ULPA LVG1224104H14 LVGEL 305x610x104 99,995 H14 71,5 300/90 750/240 0,02 6 1F 5 LVG2424104H14 LVGEL 610x610x104 99,995 H14 14,3 600/90 1500/240 0,04 12 1F LVG2448104H14 LVGEL 1220x610x104 99,995 H14 29 120/90 3000/240 0,08 25 1F HIGH TEMPERA- LVG121280U15 LVGEL 305x305x80 99,9995 U15 2,5 125/150 225/230 0,007 1,4 1F LVG122480U15 1F TURE LVG181880U15 LVGEL 610x305x80 99,9995 U15 5,5 300/150 450/230 0,01 2,75 1F LVG242480U15 1F 6 LVG243680U15 LVGEL 457x457x80 99,9995 U15 6 340/150 500/230 0,02 3,10 1F LVG244880U15 1F EQUIP- LVGEL 610x610x80 99,9995 U15 11 600/150 900/230 0,03 5,5 MENTS LVGEL 610x915x80 99,9995 U15 16,5 900/150 1500/230 0,04 8,25 7 LVGEL 1220x610x80 99,9995 U15 22 1200/150 2000/230 0,06 11 MOTORS AND LVG1224104U15 LVGEL 610x305x104 99,9995 U15 7,15 300/110 750/300 0,02 6 1F 12 1F TURBINES LVG2424104U15 LVGEL 610x610x104 99,9995 U15 14,3 600/110 1500/300 0,04 25 1F 8 LVG2448104U15 LVGEL 1220x610x104 99,9995 U15 29 1200/110 3000/300 0,08 ADSOR- *UxP *Stock TION AND Units per box F: Manufacturer, S: Stock, SL: Limited Stock DESODO- RIZATION Venfilter 9 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com INTER- 142 NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Laminarven GV INFORMA- TION Absolute Filtration / Clean Rooms Class: E, H and U 1 Terminal or air return filtration in clean rooms and lami- PRE- nar flow cabins. FILTERS Technical features 2 Type: Laminar Flow HEPA Panel. PAINTINGS Frame: Galvanized. BOOTHS Filtering Element: Glass microfiber paper. Separators: Thermoplastic glue beads. 3 Sealant: Polyurethane. Joint: Gasket with plane profile of neoprene. COMFORT OPTIMAL PRESSURE FOR FILTER FIXING: 70KPa PRODUCTS MPPS Efficiency: 85%, 99.95% and 99.995% EN 1822 Class: E10, H13 and H14. 4 Recommended Final Pressure Pressure Drop: 600 Pa. Temperature: 80ºC in continuous service. EPA/HEPA /ULPA Advantages 5 - 100% scanned in accordance with regulation EN 1822-4. - DOUBLE LABELLING ATTACHED. HIGH TEMPERA- References TURE Reference Model Dimensions Efficiency EN 1822 Filter Nominal Maximum Unit Weight UxP* Stock BxHxP (MPPS Class Surface Flow Nominal Volume (Kg) * 6 LVGV121278H13 LVGV78 E%) 0.45 LVGV122478H13 LVGV78 305x305x78 (m2) Flow (m3) EQUIP- LVGV181878H13 LVGV78 610x305x78 (m3/h)/Pa (m3/h)/Pa MENTS LVGV222278H13 LVGV78 457x457x78 99,95 H13 2,5 125/95 250/180 0,007 1.4 1F LVGV242478H13 LVGV78 575x575x78 99,95 H13 5,5 300/95 540/180 7 LVGV121278H14 LVGV78 610x610x78 99,95 H13 6 340/95 600/180 0,01 2,75 1 F LVGV122478H14 LVGV78 305x305x78 99,95 H13 9,9 535/95 970/180 MOTORS LVGV181878H14 LVGV78 610x305x78 99,95 H13 11 600/95 1100/180 0,02 3.10 1 F AND LVGV222278H14 LVGV78 457x457x78 99,995 H14 2,5 125/120 250/230 LVGV242478H14 LVGV78 575x575x78 99,995 H14 5,5 300/120 540/230 0,03 5 1F TURBINES 610x610x78 99,995 H14 6 340/120 600/230 99,995 H14 9,9 535/120 970/230 0,03 5.5 1F 8 99,995 H14 11 600/120 1100/230 0,007 1.4 1F ADSOR- TION AND 0,01 2,75 1 F DESODO- RIZATION 0,02 3.10 1 F 9 0,03 5 1F INTER- 0,03 5.5 1F NATONAL NORMATI- *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock VE Venfilter [email protected] 143 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493

0 EPA/HEPA/ULPA Dimensions Certification INFORMA- Laminarven DM TION Absolute Filtration / Clean Rooms 1 Class: E, H and U PRE- Terminal or air return filtration in clean rooms and lami- FILTERS nar flow cabins. 2 Technical features PAINTINGS Type: Laminar Flow HEPA Panel. BOOTHS Frame: DM Wood. Filtering Element: Glass microfiber paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Joint: Gasket with plane profile of neoprene. PRODUCTS OPTIMAL PRESSURE FOR FILTER FIXING: 70KPa MPPS Efficiency: 85%, 99.95% and 99.995% 4 EN 1822 Class: E10, H13 and H14. Recommended Final Pressure Pressure Drop: 600 Pa. EPA/HEPA Temperature: 80ºC in continuous service. /ULPA Advantages 5 - 100% scanned in ccordance with regulation EN 1822-4. HIGH - DOUBLE LABELLING ATTACHED. TEMPERA- References TURE Reference Model Dimensions Efficiency EN 1822 Filter Nominal Maximum Unit Weight UxP* Stock 6 BxHxP (MPPS E%) Class Surface Flow Nominal Volume (Kg) * 0.45 EQUIP- 305x305x78 (m2) Flow (m3) 1.4 1F MENTS 610x305x78 (m3/h)/Pa (m3/h)/Pa 2,75 1F LVDM121278H13 LVDM78 457x457x78 99,95 H13 2,5 125/95 250/180 0,007 3.10 1F 7 LVDM122478H13 LVDM78 575x575x78 99,95 H13 5,5 300/95 540/180 0,01 1F LVDM181878H13 LVDM78 610x610x78 99,95 H13 6 340/95 600/180 0,02 5 1F MOTORS LVDM222278H13 LVDM78 305x305x78 99,95 H13 9,9 535/95 970/180 0,03 5.5 1F AND LVDM242478H13 LVDM78 610x305x78 99,95 H13 11 600/95 1100/180 0,03 1.4 1F LVDM121278H14 LVDM78 457x457x78 99,995 H14 2,5 125/120 250/230 0,007 2,75 1F TURBINES LVDM122478H14 LVDM78 575x575x78 99,995 H14 5,5 300/120 540/230 0,01 3.10 1F LVDM181878H14 LVDM78 610x610x78 99,995 H14 6 340/120 600/230 0,02 5 1F 8 LVDM222278H14 LVDM78 99,995 H14 9,9 535/120 970/230 0,03 5.5 LVDM242478H14 LVDM78 99,995 H14 11 600/120 1100/230 0,03 ADSOR- TION AND *UxP *Stock DESODO- Units per box F: Manufacturer, S: Stock, SL: Limited Stock RIZATION Venfilter 9 Tel +34 937 862 607 [email protected] INTER- Fax +34 937 862 493 www.venfilter.com NATONAL 144 NORMATI- VE

EPA/HEPA/ULPA 0 Terminal block Dimensions INFORMA- without regulation Certification TION Absolute Filtration / Clean Rooms 1 Class: H and U PRE- Terminal Block without regulation for terminal filtration FILTERS or air return in clean rooms. 2 Technical features PAINTINGS Type: HEPA/ULPA laminar flow Diffuser-Filter H14. BOOTHS Frame: Extruded and anodized aluminum profile. Filtering Element: Glass microfiber paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Protective grille: Steel grille at the outlet, painted with white PRODUCTS epoxy. Joint: Self-adhesive Neoprene Seal. 4 Attachment: Ext. O-neck 200, 250 and 315 mm. (according to model). EPA/HEPA MPPS Efficiency: 99.995% % and 99,9995% /ULPA EN 1822 Class: H14 and U15. Recommended Final Pressure Pressure Drop: 600 Pa. 5 Temperature: 80ºC in continuous service. HIGH Advantages TEMPERA- - Low weight, reduced depth monoblock filtering. TURE - These filters are assembled and installed with a one-piece semi-circular polyurethane seal at the outlet in order to prevent particle migration or leakage between the filter and the racks or the frames of the installation 6 structure. EQUIP- Photo detail joint MENTS Venfilter [email protected] 145 7 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 MOTORS AND TURBINES 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency EN 1822 Nominal Initial Neck Unit Weight UxP Stock 1 BxHxP (MPPS E %) Class flow Pa Volume (Kg) * * BTSR122405/200H14 BTSR (m3/h) 200 PRE- BTSR242405/250H14 BTSR 610x305x125 99,995% H14 300 140 250 (m3) 3.5 1 F FILTERS BTSR243605/250H14 BTSR 610x610x125 99,995% H14 600 140 250 0,03 71 F BTSR244805/250H14 BTSR 915x610x125 99,995% H14 900 140 250 0,05 10 1 F 2 BTSR121206/200H14 BTSR 1220x610x125 99,995% H14 1200 140 200 0,07 13 1 F BTSR122406/250H14 BTSR 305x305x152 99,995% H14 150 140 200 0,10 21 F PAINTINGS BTSR181806/250H14 BTSR 610x305x152 99,995% H14 300 140 250 0,02 3.5 1 F BOOTHS BTSR242406/250H14 BTSR 457x457x152 99,995% H14 340 140 250 0,03 61 F BTSR243606/250H14 BTSR 610x610x152 99,995% H14 600 140 250 0,03 71 F 3 BTSR244806/250H14 BTSR 915x610x152 99,995% H14 900 140 250 0,06 10 1 F BTSR112306/200H14 BTSR 1220x610x152 99,995% H14 1200 140 200 0,09 13 1 F COMFORT BTSR232306/250H14 BTSR 600x300x152 99,995% H14 300 140 250 0,12 3.5 1 F PRODUCTS BTSR233506/250H14 BTSR 600x600x152 99,995% H14 600 140 250 0,03 71 F BTSR234706/250H14 BTSR 900x600x152 99,995% H14 900 140 250 0,06 10 1 F 4 1200x600x152 99,995% H14 1200 140 0,09 13 1 F 0,12 EPA/HEPA /ULPA BTSR242406/315H14 BTSR 610x610x152 99,995% H14 600 140 315 0,06 8 1F 5 BTSR243606/315H14 BTSR 915x610x152 99,995% H14 900 140 315 0,09 12 1 F HIGH BTSR244806/315H14 BTSR 1220x610x152 99,995% H14 1200 140 315 0,12 16 1 F TEMPERA- BTSR122406/200U15 BTSR 305x610x152 99,9995% U15 300 170 200 0,03 3,5 1 F TURE BTSR242406/250U15 BTSR 610x610x152 99,9995% U15 600 170 250 0,06 7 1F 6 BTSR244806/250U15 BTSR 1220x610x152 99,9995% U15 1200 170 250 0,12 13 1 F EQUIP- MENTS *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock 7 Venfilter MOTORS AND Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com TURBINES 146 8 ADSOR- TION AND DESODO- RIZATION 9 INTER- NATONAL NORMATI- VE

EPA/HEPA/ULPA Dimensions 0 Certification Terminal block INFORMA- with regulation TION Absolute Filtration / Clean Rooms 1 Class: H and U PRE- Terminal Block with regulation for terminal filtration or FILTERS air return in clean rooms. 2 Technical features PAINTINGS Type: HEPA/ULPA laminar flow Diffuser-Filter H14. BOOTHS Frame: Extruded and anodized aluminum profile. Filtering Element: Glass microfiber paper. 3 Separators: Thermoplastic glue beads. Sealant: Polyurethane. COMFORT Protective grille: Steel grille at the outlet painted with white PRODUCTS epoxy. Joint: Self-adhesive Neoprene Seal. 4 Attachment: Ext. O-neck 200, 250 and 315 mm. (according to model). EPA/HEPA MPPS Efficiency: 99.995% and 99.9995% /ULPA EN 1822 Class: H14 and U15. Recommended Final Pressure Pressure Drop: 600 Pa. 5 Temperature: 80ºC in continuous service. HIGH Advantages TEMPERA- - Low weight, reduced depth mono-block filtering. TURE - These filters are assembled and installed with a one-pie- ce semi-circular polyurethane seal at the outlet in order 6 prevent particle migration or leakage between the filter and the racks or the frames of the installation structure. EQUIP- - Flow-regulation with Pressure Drop and room conta- MENTS mination level testing. - A diffuser plate can be adjusted from the regulation 7 system in order to distribuite the air in the plenum envely over the filter surface. MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DESODO- RIZATION 9 [email protected] 147 INTER- www.venfilter.com NATONAL NORMATI- VE

0 EPA/HEPA/ULPA INFORMA- References TION Reference Model Dimensions Efficiency EN 1822 Nominal Initial Neck Unit Weight UxP Stock 1 BxHxP (MPPS Class flow Pa Inlet Volume (Kg) ** BTCR122405/200H14 BTCR E %) PRE- BTCR242405/250H14 BTCR 610x305x125 H14 (m3/h) 140 200 (m3) 4 1F FILTERS BTCR243605/250H14 BTCR 610x610x125 99,995% H14 300 140 250 0,03 8 1F BTCR244805/250H14 BTCR 915x610x125 99,995% H14 600 140 250 0,05 12 1F 2 BTCR122406/200H14 BTCR 1220x610x125 99,995% H14 900 140 250 0,07 16 1F BTCR181806/250H14 BTCR 610x305x152 99,995% H14 1200 140 200 0,10 4 1F PAINTINGS BTCR242406/250H14 BTCR 457x457x152 99,995% H14 300 140 250 0,03 7 1F BOOTHS BTCR243606/250H14 BTCR 610x610x152 99,995% H14 340 140 250 0,03 8 2F BTCR244806/250H14 BTCR 915x610x152 99,995% H14 600 140 250 0,06 12 1F 3 BTCR112306/200H14 BTCR 1220x610x152 99,995% H14 900 140 250 0,09 16 1F BTCR232306/250H14 BTCR 600x300x152 99,995% H14 1200 140 200 0,12 4 1F COMFORT BTCR233506/250H14 BTCR 600x600x152 99,995% H14 300 140 250 0,03 8 1F PRODUCTS BTCR234706/250H14 BTCR 900x600x152 99,995% H14 600 140 250 0,06 12 1F 1200x600x152 99,995% H14 900 140 250 0,09 16 1F 99,995% 1200 0,12 4 BTCR242406/315H14 BTCR 610x610x152 99,995% H14 600 140 315 0,06 8 1F BTCR243606/315H14 BTCR 915x610x152 99,995% H14 900 140 315 0,09 12 1F EPA/HEPA BTCR244806/315H14 BTCR 1220x610x152 99,995% H14 1200 140 315 0,12 16 1F /ULPA BTCR122406/200U15 BTCR 610x305x152 99,9995% U15 300 170 200 0,03 4 1F 5 BTCR242406/250U15 BTCR 610x610x152 99,9995% U15 600 170 250 0,06 8 1F BTCR244806/250U15 BTCR 1220x610x152 99,9995% U15 1200 170 250 0,12 16 1F HIGH TEMPERA- *UxP *Stock Units per box F: Manufacturer, S: Stock, SL: Limited Stock TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- 148 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DESODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL NORMATI- VE


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook