EPA/HEPA/ULPA 0 Replaceable terminal filter INFORMA- hood without regulation TION Absolute Filtration / Clean Rooms 1 Class: H and U PRE- FILTERS Terminal unit for HEPA / ULPA filters replaceable from Dimensions 2 the room. Certification PAINTING Technical features BOOTHS Type: Terminal Unit for HEPA / ULPA laminar flow filters. 3 Frame: Extruded and anodized aluminum profile. Installation: It is installed from the side of the clean room. The COMFORT replacement is repositioned and held by means of 4 support PRODUCTS springs. Filtering Element: LAMINARVEN gel seal filter. 4 Separators: Thermoplastic glue beads. Sealling: It is achieved automatically by penetration of the living edge EPA/HEPA of the box in its fluid seal. /ULPA Protective grid: Steel grid at the air outlet, white epoxy painted. MPPS Efficiency: 99,995%. 5 EN 1822 Class: H14 - U15. Recommended Final Pressure Drop: 600 Pa. HIGH Temperature: 80ºC in continuous service. TEMPERA- Advantages TURE - Very light weight and easy to install. 6 - Factory tested and certified filter. - Ease of filter change from the side of the clean room. - Terminal or collar air return filtration in clean rooms. - Air inlet neck available in various diameters. References EQUIP- MENTS Reference Model Dimensions For filters Filter Efficiency EN Filter Nominal Initial Unit Weight UxP Stock 7 BxHxP BxHxP model (MPPS 1822 surface flow Pa Volume (Kg) ** BTSRR1212/250H14 BTSRR E %) Class (m3/h) MOTORS BTSRR1212/250U15 BTSRR LVGRB 99,995 H14 (m2) (m3) 1F AND BTSRR1224/250H14 BTSRR LVGRB 99,995 U15 1F BTSRR1224/250U15 BTSRR 305x305x165 270x270x104 LVGRB 99,995 H14 2,7 150 120 0,03 5,5 1F TURBINES BTSRR2424/250H14 BTSRR 305x305x165 270x270x104 LVGRB 99,995 U15 1F BTSRR2424/250U15 BTSRR 610x305x165 575x270x104 LVGRB 99,995 H14 2,7 150 145 0,03 5,5 1F 8 BTSRR2436/250H14 BTSRR 610x305x165 575x270x104 LVGRB 99,995 U15 1F BTSRR2436/250U15 BTSRR 610x610x165 575x575x104 LVGRB 99,995 H14 5,8 300 120 0,06 8,0 1F ADSOR- BTSRR2448/250H14 BTSRR 610x610x165 575x575x104 LVGRB 99,995 U15 1F TION AND BTSRR2448/250U15 BTSRR 915x610x165 880x575x104 LVGRB 99,995 H14 5,8 300 145 0,06 8,0 1F DEODO- 915x610x165 880x575x104 LVGRB 99,995 U15 1F RIZATION 1220x610x165 1185x575x104 12,6 600 120 0,11 13,5 1220x610x165 1185x575x104 9 12,6 600 145 0,11 13,5 INTER- 19,2 900 120 0,16 19,5 NATONAL 19,2 900 145 0,16 19,5 REGU- LATION 25,9 1200 120 0,21 26,0 25,9 1200 145 0,21 26,0 *UxP *Stock Units per box F: Manufacture, S: Stock, SL: Limited Stock Venfilter [email protected] 149 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
0 EPA/HEPA/ULPA INFORMA- Graphics TION Replaceable terminal filter hood without regulation 1 BTSRR-H14 PRE- FILTERS Initial Pressure Drop(Pa) 190 171 2 152 90 180 270 360 450 540 630 720 810 133 PAINTING 114 Airflow rate (m3/h) BOOTHS 95 76 3 57 38 COMFORT 19 PRODUCTS 0 4 0 EPA/HEPA Venfilter [email protected] /ULPA Tel +34 937 862 607 www.venfilter.com 150 Fax +34 937 862 493 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 Microven (MDF) INFORMA- TION Function of Initial Pressure Drop vs. flow rate MCDMP-150 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4250 4 MCDMP-292 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 4250 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 151 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA INFORMA- Graphic TION Microven (Galvanized) 1 Function of Initial Pressure Drop vs. flow rate PRE- MCGVP-150 FILTERS 4250 2 MCGVP-292 PAINTING BOOTHS 4250 3 Venfilter COMFORT Tel +34 937 862 607 [email protected] PRODUCTS Fax +34 937 862 493 www.venfilter.com 152 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 Astroven (MDF) INFORMA- TION Function of Initial Pressure Drop vs. flow rate AVDMPH13-150 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4250 4 AVDMPH13-292 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 4250 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 153 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA INFORMA- AVDMPPH13-150 TION 4250 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 AVDMPPH13-292 4250 EPA/HEPA 154 Venfilter [email protected] /ULPA Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 AVDMPH14-150/292 INFORMA- TION AVDMPPH14-150/292 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 155 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA INFORMA- Astroven (Galvanized) TION Function of Initial Pressure Drop vs. flow rate 1 AVGVPH13-150 PRE- 4250 FILTERS AVGVPH13-292 2 4250 PAINTING BOOTHS Venfilter 3 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com COMFORT 156 PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 AVGVPPH13-150 INFORMA- TION 1 PRE- FILTERS 2 PAINTING BOOTHS 34250 COMFORT PRODUCTS AVGVPPH13-292 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 74250 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 157 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com INFORMA- AVGVPH14-150/292 Fax +34 937 862 493 TION AVGVPPH14-150/292 1 158 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 Poliven INFORMA- TION Function of Initial Pressure Drop vs. flow rate PVGV/PV-E10 1 Pressure Drop (Pa) PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4250 4 PVGV/PV-H13/H14 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE Pressure Drop (Pa) 6 EQUIP- MENTS 7 MOTORS AND TURBINES 4250 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 159 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA [email protected] www.venfilter.com INFORMA- Laminarven 66 mm TION Function of Initial Pressure Drop vs. flow rate 1 LV-66 PRE- LV66 FILTERS Laminarven Plus 90/110 mm 2 Function of Initial Pressure Drop vs. flow rate PAINTING LV-90/110-H14 BOOTHS Venfilter 3 Tel +34 937 862 607 160 Fax +34 937 862 493 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 Function of Initial Pressure Drop vs. flow rate INFORMA- LV-90/110-U15 TION 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 Laminarven 78 mm EPA/HEPA /ULPA Function of Initial Pressure Drop vs. flow rate LV-78 H13 5 LV-78 H13 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 161 INTER- www.venfilter.com NATONAL REGU- LATION
0 EPA/HEPA/ULPA [email protected] www.venfilter.com INFORMA- Laminarven Gel TION Function of Initial Pressure Drop vs. flow rate 1 LVG-H14 PRE- LVG-U15 FILTERS Venfilter 2 Tel +34 937 862 607 162 Fax +34 937 862 493 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
EPA/HEPA/ULPA 0 Laminarven DM INFORMA- TION Function of Initial Pressure Drop vs. flow rate LVDM-H13 1 LVDM78 H13 PRE- FILTERS Laminarven GV 2 Function of Initial Pressure Drop vs. flow rate LVGV-H13 PAINTING BOOTHS LVGV78 H13 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 163 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature Dimensions INFORMA- HT-1000 TION High Temperature Filters 1 Intake and exhaust in paint spray booths up to 300ºC. PRE- FILTERS Technical features 2 Type: Flat fiberglass panel filter for high temperatures. Frame: Galvanized Steel with protective fabric on both sides PAINTING (HT-CM) or expanded aluminum (HT). BOOTHS Media: Fiberglass with a high efficiency interfacing in the air outlet. 3 Average yield % (Em): 93% Average efficiency % (Am): 98% COMFORT EN 779 Class: G4 and M5. PRODUCTS Recommended Final Pressure Drop: 250 Pa. Temperature: G4 300ºC, M5 200ºC. 4 References EPA/HEPA /ULPA Reference Dimensions Average Efficiency EN 779 Nominal Initial Unit Weight UxP Stock BxHxP % (Am) Class flow Pa Volume (Kg) * * 5 HT202014 (m3/h) HT242414 480x480x14 93% G4 1000 70 (m3) 0.25 25 S HIGH HT-CM202018 610x610x14 93% G4 1600 70 0.11 0.4 25 F TEMPERA- HT-CM242418 490x490x18 93% G4 1000 70 0.13 0.35 25 S 610x610x18 93% G4 1600 70 0.11 0.5 25 F TURE 0.13 6 HT202014F5 480x480x14 98% M5 350 50 0.11 0.35 25 F HT-CM202018F5 490x490x18 98% M5 350 50 0.13 0.5 25 F EQUIP- MENTS *UxP *Stock Units per box F: Manufacture, S: Stock, SL: Limited Stock 7 Venfilter MOTORS AND 164 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
High temperature Dimensions 0 Certification Quebraven Galvanized INFORMA- High Temperature TION High Temperature Pre-filtration 1 Metallic prefilter (Galvanized) for the retention of coarser PRE- particles in industrial installations and processes with FILTERS large airflow and high temperatures in small spaces. Si- licone free. 2 Technical features PAINTING BOOTHS Type: Disposable filter with an uneven surface, zigzag plea- ted, fiber glass media and grid on one side. 3 Frame: Galvanized Steel. Grid: Galvanized grid on one side. COMFORT Media: Fiber glass. PRODUCTS EN 779 Class: G4. Recommended Final Pressure Drop: 250 Pa. 4 Temperature: 270ºC. References EPA/HEPA /ULPA 5 Reference Dimensions Average EN 779 *ME ISO 16890 Filter Nominal Initial Unit UxP Stock HIGH BxHxP Efficiency Class % surface flow Pa Volume * * TEMPERA- QMHT242404G4 % (Am) 35 Coarse 60% (m3/h) QMHT202404G4 QMHT 592x592x96 G4 Coarse 60% (m2) 110 (m3) 3.5 SL TURE QMHT202004G4 QMHT 592x492x96 G4 35 Coarse 60% 110 0.03 3.3 F QMHT122404G4 QMHT 492x492x96 G4 Coarse 60% 2.2 3400 110 0.028 3.2 F 6 QMHT242402G4 QMHT 592x287x96 G4 Coarse 60% 110 0.023 1.75 F QMHT202402G4 QMHT 592x592x48 G4 Coarse 60% 1.8 2800 100 0.015 2.3 SL QMHT202002G4 QMHT 592x492x48 G4 Coarse 60% 100 0.02 1.7 F QMHT122402G4 QMHT 492x492x48 G4 Coarse 60% 1.5 2500 100 0.014 1.6 F QMHT 592x287x48 G4 100 0.012 1.2 F 1.1 1700 0.01 EQUIP- MENTS 1.1 2000 0.90 1650 7 0.75 1375 MOTORS AND 0.60 1000 TURBINES *UxP *Stock Units per box F: Manufacture, S: Stock, SL: Limited Stock 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 165 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature INFORMA- Variven HT TION High Temperature Filters 1 Filtration in paint both and Paint Ovens. PRE- FILTERS 2 Technical features Dimensions PAINTING Type: Compact High Efficiency filter for high temperatures. VVHTP VVHT BOOTHS Frame: Galvanized Steel. Media: Fiberglass Paper. Certification 3 Separators: Corrugated aluminum or Fiberglass Strips Sealant: Fiberglass COMFORT Flange: Galvanized Steel. PRODUCTS Gasket: Fiberglass with an outer coating or ceramic. Average efficiency % (Am): 60 Em 80% and 90 Em 95%. 4 EN 779 Class: M6 and F8. ISO 16890: ePM10 65% and ePM1 65%. EPA/HEPA Recommended Final Pressure Pressure Drop: 450 Pa. /ULPA Temperature: Max. in service: 250ºC, Max. in peaks 350ºC. VVHTP: With flange. 5 VVHT: Without flange. HIGH Advantages TEMPERA- - Silicone Free. TURE References 6 Reference Model Dimensions EN *ME ISO 16890 Filter Nominal Initial Energy Energy Energy Unit Weight UxP S. EQUIP- BxHxP 779 % MENTS VVHTP242412F8 VVHTP Class ePM1 65% surface flow Pa Class Cons. Cons. Volume (Kg) * * VVHTP202412F8 VVHTP ePM1 65% 7 VVHTP122412F8 VVHTP (m2) (m3/h) 16890 kWh/ kWh/ (m3) VVHTP122406F8 VVHTP MOTORS VVHTP242412F6 VVHTP **** year year AND VVHTP202412F6 VVHTP VVHTP122412F6 VVHTP 779 16890 TURBINES VVHTP122406F6 VVHTP * ** 8 592x592x292 F8 65 12 3400 150 D 2550 1891 0.11 8.2 1 S ADSOR- 490x592x292 TION AND 9 2750 D 0.09 7.8 1 F DEODO- RIZATION 287x592x292 ePM1 65% 6 1700 D 0.05 4.2 1 F 287x592x150 9 592x592x292 ePM1 65% 3 850 D 0.03 2.8 1 F 490x592x292 INTER- 287x592x292 M6 ePM10 65% 12 3400 130 E 2000 >1200 0.11 8.2 1 F NATONAL 287x592x150 ePM10 65% 9 2750 E 0.09 7.8 1 F REGU- LATION ePM10 65% 6 1700 E 0.05 4.2 1 F ePM10 65% 3 850 E 0.03 2.8 1 F * ME%: Minimum Efficiency EN779: 2012 *UxP *Stock * Energy Consumption kWh / year: Calculated according to Eurovent 4 / 21-2017 guidelines. Units per box F: Manufacture, S: Stock, SL: Limited Stock ** Energy Consumption kWh / year: Calculated according to Eurovent guidelines. **** Energy class according to Eurovent. Venfilter 166 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com
High temperature 0 INFORMA- TION References 1 Reference Model Dimensions EN 779 *ME ISO 16890 Filter Nominal Initial Energy Energy Energy Unit Weight UxP Stock BxHxP Class % surface flow Pa Class Cons. Cons. Volume (m3/h) 16890 kWh/ kWh/ (Kg) * * (m2) **** year year (m3) PRE- 779 16890 FILTERS * ** 211 1 F VVHT242412F8 VVHT 610x610x292 F8 65 ePM1 65% 14 4250 160 n.a. n.a. n.a. 0.11 VVHT122412F8 VVHT 305x610x292 F8 ePM1 65% 7 2125 6 1F VVHT242478F8 VVHT 610x610x78 7.5 2000 0.05 VVHT243678F8 VVHT 915x610x78 F8 69 ePM1 60% 11.25 3000 4.4 1 F PAINTING VVHT183678F8 VVHT 915x457x78 M6 ePM1 60% 8.5 2250 100 n.a. n.a. n.a. 0.09 6.5 1 F BOOTHS VVHT191978F8 VVHT 480x480x78 M6 ePM1 60% 4.6 1240 4.9 1 F VVHT242455F8 VVHT 610x610x55 ePM1 60% 7.5 2000 0.06 VVHT242412F6 VVHT 610x610x292 ePM1 60% 14 4250 32.7 1 F VVHT122412F6 VVHT 305x610x292 7 2125 0.12 VVHT242478F6 VVHT 610x610x78 n.a. ePM10 65% 7.5 2500 3.9 1 F VVHT243678F6 VVHT 915x610x78 ePM10 65% 11.25 3750 0.06 VVHT183678F6 VVHT 915x457x78 8.5 2800 11 1 F VVHT191978F6 VVHT 480x480x78 n.a. ePM10 65% 4.6 1550 n.a. n.a. n.a. n.a. 0.06 VVHT242455F6 VVHT 610x610x55 ePM10 65% 7.5 2500 6 1 F COMFORT ePM10 65% n.a. n.a. n.a. n.a. 0.11 4.4 1 F PRODUCTS ePM10 65% 6.5 1 F ePM10 65% 0.05 4.9 1 F n.a. n.a. n.a. n.a. 0.09 42.7 1 F 0.06 3.9 1 F 0.12 0.06 0.06 *UxP *Stock *ME%: Minium Efficiency to EN779:2012 EPA/HEPA Units per box F: Manufacture, S: Stock, SL: Limited Stock /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 167 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature INFORMA- Micropac HT TION High Temperature Filters 1 PRE- FILTERSFiltFrailttiroantiionncianbpinasin&t bPoaoitnhtsinagnOdvPenaisn.t Ovens 2 Technical features Dimensions Certification PAINTING Type: Compact High Efficiency filter for high temperatures. BOOTHS Frame: Extruded and anodized aluminium. Media: Fiberglass Paper. 3 Separators: Fiberglass Strips. Gasket: Fiberglass with an outer coating. COMFORT EN 1822 Class: E10. PRODUCTS Protective grid: Perforated aluminium on both sides. Average efficiency % (Am): 85% 4 Recommended Final Pressure Drop: 450 Pa Temperature: 250ºC EPA/HEPA /ULPA Advantages 5 - Filtration in paint booths and Painting Ovens. - Silicone Free. HIGH References Model Dimensions Efficiency EN 1822 Filter Nominal Initial Weight UxP Stock TEMPERA- BxHxP (MPPS Class Surface flow Pa Reference E%) TURE 663x358x48 85 E10 (m2) (m3/h) 60 663x663x48 85 E10 3,5 360 60 (Kg) * * 6 625x320x38 85 E10 7 420 60 MPHT35866348H10 MPHT 625x625x38 85 E10 2,5 150 60 3,2 1 F EQUIP- MPHT66366348H10 MPHT 5 300 5,5 1 F MENTS MPHTP62532038H10 MPHT 3 1F MPHTP62562538H10 MPHT 5 1F 7 *UxP *Stock *ME%: Minium Efficiency to EN779:2012 MOTORS Units per box F: Manufacture, S: Stock, SL: Limited Stock AND TURBINES 8 ADSOR- 168 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
High temperature Dimensions 0 Certification Multiven HT 120º INFORMA- TION Air Treatment 1 Inlet, outlet and recirculation in ventilation systems re- quiring HIGH TEMPERATURE: air conditioning equipment PRE- (air conditioning units, ventilation chambers, etc.), air FILTERS conditioning systems (hospitals, laboratories, museums, airports, etc.), industrial processes (pharmaceutical, food, 2 optics, microelectronics, veterinary chemical and surface treat ment industries and as a pre-filter for Hepa and Ulpa PAINTING filters. BOOTHS Technical features 3 Type: Compact multihedral rigid bag filter. COMFORT Frame: Polycarbonate. PRODUCTS Media: Fiberglass paper. Separators: High temperature glue beads. 4 Sealant: Polyurethane. Average Efficiency % (Em): 60% ‹ Em ‹ 80%, 80% ‹ Em ‹ 90%, EPA/HEPA 90% ‹ Em ‹ 95% and 95% ‹ Em. /ULPA EN 779 Class: M6, F7, F8 and F9. ISO 16890: ePM10 65%, ePM1 50%, ePM1 65% and ePM1 80%. 5 Recommended Final Pressure Drop: 600 Pa. Temperature: 120-150ºC continuous service. HIGH TEMPERA- Advantages TURE - High Capacity of dust retention. - Temperature: 120° C continuous service. 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 169 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature INFORMA- References TION 1 Reference Model Dimensions EN ME ISO 16890 Nominal Nominal Unit Weight UxP Stock BxHxP 779 % flow flow PRE- Class Volume (Kg) * * FILTERS (m3/h)/Pa (m3/h)/Pa (m3) 4250/155 3400/115 MVHT120242412F9 MVHT120 592x592x292 F9 80 ePM1 80% 0.12 5 1 F MVHT120202412F9 MVHT120 592x492x292 ePM1 80% 3500/155 2800/115 0,09 4 1 F 2 MVHT120122412F9 MVHT120 592x292x292 ePM1 80% 2125/155 1750/115 0,06 3 1 F MVHT120242412F8 MVHT120 592x592x292 F8 65 ePM1 65% 4250/125 3400/92 0,12 5 1F MVHT120202412F8 MVHT120 592x492x292 ePM1 65% 3500/125 2800/92 0,09 4 1F PAINTING MVHT120122412F8 MVHT120 592x292x292 ePM1 65% 2125/125 1750/92 0,06 3 1F BOOTHS MVHT120242412F7 MVHT120 592x592x292 F7 54 ePM1 50% 4250/115 3400/78 0,12 5 1F MVHT120202412F7 MVHT120 592x492x292 ePM1 50% 3500/115 2800/78 0,09 4 1F 3 MVHT120122412F7 MVHT120 592x292x292 ePM1 50% 2125/115 1750/78 0,06 3 1F MVHT120242412F6 MVHT120 592x592x292 MVHT120202412F6 MVHT120 592x492x292 M6 ePM10 65% 4250/100 3400/65 0,12 5 1F ePM10 65% 3500/100 2800/65 0,09 4 1F COMFORT MVHT120122412F6 MVHT120 592x292x292 ePM10 65% 2125/100 1750/65 0,06 3 1F PRODUCTS * ME%: Minimum Efficiency EN779: 2012 4 * Energy Consumption kWh / year: Calculated according to Eurovent 4 / 21-2017 guidelines. *UxP *Stock ** Energy Consumption kWh / year: Calculated according to Eurovent guidelines. Units per box F: Manufacture, S: Stock, SL: Limited Stock **** Energy class according to Eurovent. EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- 170 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
High temperature 0 Multiven HT 350ºC Dimensions INFORMA- Certification TION Air Treatment 1 Inlet, outlet and recirculation in ventilation systems re- quiring HIGH TEMPERATURE: air conditioning equipment PRE- (air conditioning units, ventilation chambers, etc.), air FILTERS conditioning systems (hospitals, laboratories, museums, airports, etc.), industrial processes (pharmaceutical, food, 2 optics, microelectronics, veterinary chemical and surface treat ment industries and as a pre-filter for Hepa and Ulpa PAINTING filters. BOOTHS Technical features 3 Type: Compact multihedral rigid bag filter. COMFORT Frame: Polycarbonate. PRODUCTS Media: Fiberglass paper. Separators: High temperature glue beads. 4 Sealant: Polyurethane. Average Efficiency % (Em): 60% ≤ Em < 80% and 90% ≤ Em < 95%. EPA/HEPA EN 779 Class: M6 and F8. /ULPA ISO 16890: ePM10 60% and ePM1 60%. Recommended Final Pressure Drop: 450 Pa. 5 Temperature: 350ºC continuous service. Advantages - Temperature: 120°C continuous service. References HIGH TEMPERA- Reference Model Dimensions EN *ME ISO 16890 Nominal Initial Energy Energy Energy Unit UxP S BxHxP 779 % flow Pa Class Cons. Cons. Volume * * TURE Class (m3/h) 16890 kWh/ kWh/ **** year year (m3) F 6 779 16890 F MVGVHT350232312F8 MVGVHT350 592x592x292 F8 85 ePM1 60% 3400 140 D 0,12 1 F EQUIP- MVGVHT350202312F8 MVGVHT350 592x492x292 M6 ePM1 60% 2500 97 D * ** 0,09 1 F MENTS MVGVHT350112312F8 MVGVHT350 592x287x292 ePM1 60% 1700 D 1830 1900 0,06 1 F MVGVHT350232312F6 MVGVHT350 592x592x292 3400 E 0,12 1 F 7 MVGVHT350202312F6 MVGVHT350 592x492x292 65 ePM10 60% 2500 E 1426 >1200 0,09 1 F MVGVHT350112312F6 MVGVHT350 592x287x292 ePM10 60% 1700 E 0,06 1 MOTORS MVGVHT350242416F6 MVGVHT350 610x305x400 ePM10 60% 1700 - 0,09 1 AND ePM10 60% TURBINES * ME%: Minimum Efficiency EN779: 2012 8 * Energy Consumption kWh / year: Calculated according to Eurovent 4 / 21-2017 guidelines. ADSOR- *UxP *Stock ** Energy Consumption kWh / year: Calculated according to Eurovent guidelines. TION AND Units per box DEODO- F: Manufacture, S: Stock, SL: Limited Stock **** Energy class according to Eurovent. RIZATION Venfilter [email protected] 171 9 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 INTER- NATONAL REGU- LATION
0 High temperature Dimensions Certification INFORMA- Poliven HT 120ºC TION High Temperature Filters 1 The HEPA absolute filters are used for filtration of inlet, PRE- outlet and recirculation air in ventilation systems such FILTERS as: Clean Rooms, Operating Theatres, Laboratories, etc. , Industrial Processes: Microelectronics, food industry, op- 2 tics, pharmaceutical industry, fine chemistry, etc. Treat- ment of dangerous substances: Asbestos, Metal dust, PAINTING Bacteria, Viruses, Radioactive Particles. BOOTHS Technical features 3 Type: Compact multihedral Absolute Filter with Very High COMFORT Efficiency and Large Flow. PRODUCTS Frame: Galvanized Steel, with handle Filtering Element: Glass microfiber paper. 4 Separators: Glue beads Higt Temperature. Sealant: Polyurethane. EPA/HEPA Gasket: Bicomponent polyurethane liquid system. (Se- /ULPA mi-circular expanded polyurethane) MPPS efficiency: 85%, 99.95% and 99.995% 5 EN 1822 Class: E10, H13 and H14. Recommended Final Pressure Drop: 600 Pa. HIGH Temperature: 120-145ºC in continuous service. TEMPERA- Advantages TURE - High Nominal airflow for a low pressure drop. 6 - Filters totally interchangeable with the aluminium separator filters minipleat and with Galvanized steel or wooden frames. EQUIP- MENTS References 7 Reference Model Dimensions Efficiency Class Filter Nominal Initial Unit Weight UxP Stock BxHxP (MPPS E EN Surface flow Pa MOTORS PVGVHT120122412.4H13 1822 Volume (Kg) * * AND PVGVHT120242412.8H13 %) H13 (m2) (m3/h) 250 PVGVHT120242412.10H13 99,95% H13 16 1700 250 (m3) TURBINES PVGVHT120122412.4H14 99,95% H13 32 3400 280 PVGVHT120242412.10H14 PVGVHT120 305x610x292 99,95% H14 40 4000 280 0,05 14 1 F 8 PVGVHT120 610x610x292 99,995% H14 16 1200 280 PVGVHT120 610x610x292 99,995% 40 3000 0,12 21 1 F ADSOR- PVGVHT120 305x610x292 TION AND PVGVHT120 610x610x292 0,12 23 1 F DEODO- RIZATION 0,05 14 1 F 9 0,12 23 1 F INTER- *UxP *Stock NATONAL Units per box F: Manufacture, S: Stock, SL: Limited Stock REGU- Venfilter LATION 172 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com
High temperature 0 Poliven HT 250ºC Dimensions INFORMA- TION High Temperature Filters H 1 The absolute HEPA filters are used for filtration of air inlet, outlet PB and recirculation air in ventilation systems such as: Clean Rooms, PRE- Operating Rooms, Laboratories, etc. Industrial Processes: Certification FILTERS Microelectronics, food, optical, pharmaceutical, fine chemical, industries, etc. Treatment of Dangerous substances: Asbestos, 2 Metallurgical Powders, Bacteria, Viruses, Radioactive Particles. PAINTING Technical features BOOTHS Type: Absolute Multidihedral Compact Filter of Very High 3 Efficiency and High Flow. Frame: Galvanized or Stainless Steel. COMFORT Filter Element: Glass microfiber paper. PRODUCTS Separators: High Temperature glue beads. Sealant: Silicone. 4 Gasket: Silicone MPPS efficiency: 85%, 99.95% and 99.995%. EPA/HEPA EN 1822 Class: E10, H13 and H14. /ULPA Recommended Final Pressure Drop: 600 Pa. Temperature: 250ºC in continuous service. 5 HIGH TEMPERA- TURE Advantages 6 - High nominal flow for low Pressure Drop. EQUIP- - Filters fully interchangeable by aluminum separator filters, minipleat MENTS and with galvanized steel frames. 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 173 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature INFORMA- References Model Dimensions Efficiency EN Filtrant Nominal Initial Unit UxP Stock TION BxHxP (MPPS 1822 Surface Flow Pa Volume ** Reference PVGVHT250 E %) Class (m3/h) 1 PVGVHT250 287x595x292 99.95% H13 (m2) 1250 240 (m3) 1F PVGVHT250112312H13 PVGVHT250 305x610x292 99.95% H13 11 1250 240 0,05 1F PRE- PVGVHT250122412H13 PVGVHT250 490x595x292 99.95% H13 11 1900 240 0,05 1F FILTERS PVGVHT250202312H13 PVGVHT250 490x610x292 99.95% H13 17 1900 240 0,09 1F PVGVHT250202412H13 PVGVHT250 595x595x292 99.95% H13 17 2500 240 0,09 1F 2 PVGVHT250232312H13 PVGVHT250 610x610x292 99.95% H13 22 2500 240 0,12 1F PVGVHT250242412H13 PVGVHT250 287x595x292 99.995% H14 22 1250 260 0,12 1F PAINTING PVGVHT250112312H14 PVGVHT250 305x610x292 99.995% H14 11 1250 260 0,05 1F BOOTHS PVGVHT250122412H14 PVGVHT250 490x595x292 99.995% H14 11 1900 260 0,05 1F PVGVHT250202312H14 PVGVHT250 490x610x292 99.995% H14 17 1900 260 0,09 1F 3 PVGVHT250202412H14 PVGVHT250 595x595x292 99.995% H14 17 2500 260 0,09 1F PVGVHT250232312H14 610x610x292 99.995% H14 22 2500 260 0,12 1F COMFORT PVGVHT250242412H14 22 0,12 PRODUCTS PVINHT250112312H13 PVINHT250 287x595x292 99.95% H13 11 1250 240 0,05 1 F 4 PVINHT250122412H13 PVINHT250 305x610x292 99.95% H13 11 PVINHT250202312H13 PVINHT250 490x595x292 99.95% H13 17 1250 240 0,05 1 F EPA/HEPA PVINHT250202412H13 PVINHT250 490x610x292 99.95% H13 17 /ULPA PVINHT250232312H13 PVINHT250 595x595x292 99.95% H13 22 1900 240 0,09 1 F PVINHT250242412H13 PVINHT250 610x610x292 99.95% H13 22 5 PVINHT250112312H14 PVINHT250 287x595x292 99.995% H14 11 1900 240 0,09 1 F PVINHT250122412H14 PVINHT250 305x610x292 99.995% H14 11 HIGH PVINHT250202312H14 PVINHT250 490x595x292 99.995% H14 17 2500 240 0,12 1 F TEMPERA- PVINHT250202412H14 PVINHT250 490x610x292 99.995% H14 17 PVINHT250232312H14 PVINHT250 595x595x292 99.995% H14 22 2500 240 0,12 1 F TURE PVINHT250242412H14 PVINHT250 610x610x292 99.995% H14 22 1250 260 0,05 1 F 6 1250 260 0,05 1 F EQUIP- MENTS 1900 260 0,09 1 F 7 1900 260 0,09 1 F MOTORS 2500 260 0,12 1 F AND 2500 260 0,12 1 F TURBINES *UxP *Stock 8 Units per box F: Manufacture, S: Stock, SL: Limited Stock ADSOR- Venfilter TION AND DEODO- 174 Tel +34 937 862 607 [email protected] RIZATION Fax +34 937 862 493 www.venfilter.com 9 INTER- NATONAL REGU- LATION
High temperature 0 Graphic INFORMA- TION HT-1000 1 Function of Initial Pressure Drop vs. flow rate HT PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 Variven HT EPA/HEPA /ULPA Function of Initial Pressure Drop vs. flow rate VVHTP 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 4250 ADSOR- TION AND Venfilter DEODO- Tel +34 937 862 607 RIZATION Fax +34 937 862 493 9 [email protected] 175 INTER- www.venfilter.com NATONAL REGU- LATION
0 High temperature [email protected] www.venfilter.com INFORMA- Variven HT TION Function of Initial Pressure Drop vs. flow rate 1 VVHT PRE- 4250 FILTERS Venfilter 2 Tel +34 937 862 607 176 Fax +34 937 862 493 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 0 Purifier MIA AIR INFORMA- TION Purifiers: VEN AIR 1 Unit for air purification and immediate recirculation PRE- of indoor air. It complements the ventilation systems. FILTERS Designed for homes, offices, shops, schools, museums, medical and dental clinics, homes for the elderly, waiting 2 rooms, beauty parlours, and others. Technical features Dimensions PAINTING BOOTHS Type: MIA AIR air purifier for immediate recirculation of indoor air, turning H P polluted air into clean air in minutes, in a space up to 100m2. B 3 Construction: ABS Shock resistant. Voltage: 220-240 VAC, 50 Hz. COMFORT Power Consumption: 65W. PRODUCTS Dimensions: 52x33x21cm. Weight: 7/9 Kg. 4 Air Volume: 275 m3/h Renewals: For 25m2, the air will be renewed a minimum of 3 times an hour. EPA/HEPA Sound level:<65 dB. (A) /ULPA Control: Manual Touch Filter change indicator: LED on the device 5 Sensors: VOC, ePM1, ePM2.5, ePM10, CO2, Temperature and Moisture. Colours: White and Grease Space. HIGH TEMPERA- References TURE References Model Colour Dimensions UV Lamp Weight UxP Stock MIA-AIR/B-H13 MIA-AIR White 330x520x210mm No 18 1 SL 6 MIA-AIR/GS-H14 MIA-AIR Space Grey 330x520x210 mm No 18 1 SL EQUIP- *UxP Units per box MENTS *Stock F: Manufacture, S: Stock, SL: Limited Stock 7 Filtration MOTORS Type Dimensions mm. Efficency MPPS Class EN 1822 Treatment* AND H13 ANTIMIC HEPA FILTER 256x266x30 >99,99% TURBINES * ANITIMIC: Antimicrobial coating, viricide and fungicide. 8 Type Dimensions mm. Efficiency VOC CARBON FILTER 264x262x18 Benzene, Formaldehyde, Ozone, Toluene, Xylene, ETHYL ALCHOL, etc. Air dust Pollen Allergens Pet Chemical Smoking Microorganisms ADSOR- dandruff vapour odours TION AND DEODO- (Volatile Organic RIZATION Compounds) 9 Venfilter Tel +34 937 862 607 [email protected] 177 INTER- Fax +34 937 862 493 www.venfilter.com NATONAL REGU- LATION
0 Equipments INFORMA- TION The equipment is provided with filters on the sides, composed of: 1 - Carbon filter: Captures chemical pollutants (VOCs) suspended in the air, greatly reducing the risk of developing health problems caused by pollution. PRE- - Hepa Filter: Cleanroom filter that traps 99.99% of fine particles less than FILTERS 0.3 microns (including microbes, bacteria, viruses and nano viruses), thus preventing their spread in the air. 2 The filter is impregnated with an ANTIMIC solution that besides trapping the microorganisms, it kills them, so they cannot create colonies within the PAINTING equipment. BOOTHS The air enters through the sides where each of the filter packages are placed. As the air passes first through the charcoal filter and finally through the HEPA 3 filter, in a matter of seconds the room is totally free of particles and pollutants. Then, the powerful fan on the top starts to operate, which returns the clean and healthy air to the space, with circular distribution to ensure 360° coverage. COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 Manual Touch EQUIP- Our MIA AIR COMPACT operates with a touch screen on the top of the device. MENTS The screen has controls for ON/OFF, Increase, Reduce and Timer. It can work at 3 different levels that are changed by pressing the increase and 7 decrease buttons. The device emits a bleep when buttons are pushed excessively while adjusting levels. MOTORS The timer setting can be adjusted up to 60 minutes at 15-minute intervals. A light AND blinks while the timer is active. Effective filtration TURBINES 8 ADSOR- 178 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 0 Purifier MIA AIR PLUS INFORMA- TION Purifiers: VEN AIR 1 Unit for air purification and immediate recirculation of indoor air. It complements the ventilation systems. PRE- Designed for homes, offices, shops, schools, museums, FILTERS medical and dental clinics, homes for the elderly, waiting rooms, beauty parlours, and others. 2 Technical features Dimensions PAINTING BOOTHS Type: Air purifier MIA AIR for immediate recirculation of the interior air, H converting the polluted air into BP 3 clean in minutes, in a space of up to 100m2. Construction: ABS Shock resistant. COMFORT Voltage: 230 VAC, 50/60 Hz. PRODUCTS Power Consumption: 25-105W. Dimensions: 66x38x38 cm. 4 Weight: 16/18 Kg. Air Volume: 90 to 910 m3 / h with six speeds EPA/HEPA /ULPA 94 to 530 cfm with six speeds Renewals: For 50m2 it will renew the air a minimum of 6 times per hour. 5 For 100m2 it will renew the air a minimum of 3 times per hour. HIGH Sound level: <60 dB (Automatic mode) TEMPERA- Control: Remote by Mobile Application. (APP). Wi-Fi connection: With 802.11 b / g / n router in Wi-Fi network band of 2.4 Ghz. TURE Sensors: VOC, ePM1, ePM2.5, ePM10, CO2, Temperature and Moisture. Colours: White and Space Grey. 6 References EQUIP- MENTS References Model Colour Dimensions UV Lamp Weight UxP Stock White 380x660x380 mm No 18 1 SL 7 MIA-AIR-PLUS/BH14 MIA-AIR Space Grey 380x660x380 mm No 18 1 SL White 380x660x380 mm Yes 18 1 SL MOTORS MIA-AIR-PLUS/GSH14 MIA-AIR Space Grey 380x660x380 mm Yes 18 1 SL AND MIA-AIR-PLUS/BH14UV MIA-AIR TURBINES MIA-AIR-PLUS/GSH14UV MIA-AIR 8 *UxP Units per box ADSOR- *Stock F: Manufacture, S: Stock, SL: Limited Stock TION AND DEODO- Filtration RIZATION Type Dimensions mm. Efficency MPPS Class EN 1822 Treatment* 9 H14 ANTIMIC HEPA FILTER 260x495x60 >99,999% INTER- NATONAL * ANITIMIC: Antimicrobial coating, viricide and fungicide. ** Optional REGU- LATION Type Dimensions mm. Efficiency VOC CARBON FILTER 260x495x18 Benzene, Formaldehyde, Toluene, Xylene, ETHYL ALCHOL, etc. Venfilter [email protected] 179 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
0 Equipments INFORMA- TION The equipment is provided with filters on the sides, consisting of: 1 - Pre-filter: Filters out coarser particles. - Carbon filter: Captures chemical (VOC's) or atmospheric pollutants PRE- suspended in the air, reducing the risk of health problems FILTERS caused by pollution. - Hepa Filter: HEPA filter that traps and neutralizes particles of 0.01 microns or 2 bigger (including microbes, bacteria, viruses and nanoviruses) preventing them from spreading in PAINTING the air. BOOTHS The filter is impregnated with an ANTIMIC solution that, besides trapping the microorganisms, kills them, so they cannot create colonies within the equipment. 3 The air enters from the sides where the filter packs are placed. As the air passes first through the pre-filter, then through the carbon filter and COMFORT finally through the HEPA filter, in a matter of seconds, it is completely PRODUCTS free of particles and contaminants. Finally the powerful fan at the top returns clean and healthy air, distributing it in a circular way providing a 360º distribution. 4 APP EPA/HEPA The equipment is equipped with a router for Wi-Fi connection, which allows /ULPA connecting it to the local network and installing the APP. The practical mobile App allows having the control of the device and the conditions of its environment 5 at all times and from anywhere. Easy to install application, with only one screen, which provides instantaneous and real time information on air quality, life span of filters and gives access to all device related parameters. HIGH Different modes of operation of the device: TEMPERA- - Silent - Turbo TURE - Auto - Eco 6 - Manual EQUIP- Data provided: MENTS - Air Quality Index (AQI) - Particle counter ePM1, ePM2.5 and ePM10 7 - VOC particle counter - Temperature, Relative Humidity and CO2 level information MOTORS - Status and life span of the filter AND - Filter Status and Life Cycle TURBINES Air Quality Index Rating Table 8 ePM 2.5 VOC ADSOR- Good 0-30 Good 0-60 TION AND Moderate 30-100 Moderate 60-200 DEODO- RIZATION Poor 100-150 Poor 200-600 Unhealthy 150-200 Unhealthy 600-2000 9 Extremely Harmful 200-300 Extremely Harmful 2000-5300 INTER- Dangerous >300 Dangerous >5300 NATONAL Venfilter [email protected] REGU- Tel +34 937 862 607 www.venfilter.com LATION 180 Fax +34 937 862 493
Equipments 0 Purifier MIA AIR PLUS/20 INFORMA- TION Purifiers: VEN AIR 1 Unit for air purification, and an immediate recirculation of the interior air. It complements the ventilation PRE- systems. Designed for offices, shops, gyms, schools, FILTERS museums, medical and dental clinics, nursing homes, etc. 2 Technical features Dimensions PAINTING BOOTHS Type: Air purifier MIA AIR for immediate recirculation of the interior air, H converting the polluted air into 3 clean in minutes, in a space of up to 100m2. Construction: ABS Shock resistant. COMFORT Voltage: 220-240 VAC, 50 Hz. PRODUCTS Power Consumption: 600+16 (UV). Dimensions: 151x65x50cm. 4 Weight: 75kg. Air Volume: 2000 m3/h EPA/HEPA /ULPA Sound level: 35 -58 dbA Control: Remote by Mobile Application (APP) / Manual. 5 Sensors: VOC, PM1, PM2.5, PM10, CO2, Temperature and Humidity. Filter change indicator: LED on the device. HIGH Colours: Grease Space. TEMPERA- References BP TURE References Model Colour Dimensions UV Lamp Weight UxP Stock 6 Space Grey 1510x650x500 mm No 18 1 SL MIA-AIR-PLUS/20.U15 MIA-AIR Space Grey 1510x650x500 mm Yes 18 1 SL EQUIP- MIA-AIR-PLUS/20U15UV MIA-AIR MENTS *UxP Units per box 7 *Stock F: Manufacture, S: Stock, SL: Limited Stock MOTORS Filtration AND Type Dimensions mm. ISO16890 Class EN 779 TURBINES PREFILTER 592x400x96 Thick 65% G4 8 Type Dimensions mm. Efficency MPPS Class EN 1822 Treatment* U15 ANTIMIC ADSOR- ULPA FILTER 592x400x96 >99,9995% TION AND DEODO- * ANITIMIC: Antimicrobial coating, viricide and fungicide. RIZATION Type Dimensions mm. Efficency VOC 9 CARBON FILTER 592x400x221 Benzene, Formaldehyde, Ozone, Toluene, Xylene, ETHYL ALCHOL, etc. INTER- Air dust Pollen Allergens Pet Chemical Smoking Microorganisms NATONAL dandruff vapour odours 181 REGU- (Volatile Organic LATION Compounds) Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
0 Equipments INFORMA- TION The equipment is provided with filters on the sides, composed of: 1 - Pre-filter: Filters out the thicker particles. - Carbon filter: Captures chemical pollutants (VOCs) suspended in the air, greatly PRE- reducing the risk of developing health problems caused by pollution. FILTERS - ULPA Filter: Cleanroom Filter that traps 99.9995% of fine particles less than 0.3 microns (including microbes, bacteria, viruses, and nano viruses), thus preventing their spread in the air. 2 The filter is impregnated with an ANTIMIC solution that besides trapping the microorganisms, it kills them, so they cannot create colonies within the equipment. PAINTING The air enters through the sides where each of the filters is placed. As the air BOOTHS passes first through the charcoal filter, then the pre-filter and, finally, the ULPA filter, in a matter of seconds the room is totally free of particles and pollutants. 3 Then, the powerful fan on the top starts to operate, which returns the clean and healthy air to the space, with circular distribution to ensure 360° coverage. COMFORT PRODUCTS 4 APP EPA/HEPA No need for installation, all you need is a power outlet. Use the Mobile App to /ULPA operate the device and its surrounding conditions at all times, from anywhere. Easy to install app, with just one screen, providing instant, real-time information 5 on air quality, filter life and access to all device-related parameters. HIGH Different modes of operation of the device: TEMPERA- - Silent - Turbo TURE - Auto - Eco 6 - Manual EQUIP- Data provided: MENTS - Air Quality Indicator (AQI) - PM1, PM2.5, and PM10 particle counter 7 - VOC particles counter - Information on Temperature, Relative Humidity and CO2 levels. MOTORS - Status and Life Cycle of the filter. AND TURBINES 8 ADSOR- 182 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 0 UPA AIR Purifier INFORMA- TION Purifiers: VEN AIR 1 The main route of transmission of viruses, bacteria, dust particles and other polluting aerosols is the airway, therefore it must be controlled PRE- and reduced to the maximum in all types of buildings, especially those FILTERS where there is a high level of occupancy. The comfort and health levels of the users and workers of these spaces can be dramatically 2 improved thanks to the building facilities themselves. This includes HVAC systems and other elements such as air purifiers. PAINTING BOOTHS Dimensiones 3 Technical features COMFORT Type: UPA series filtration units. H PRODUCTS Construction: Smooth interior and exterior finishes, without screws, making them easy to clean and maintain. P 4 Rock wool insulation in 30mm thick panels. Access: Access for maintenance in all equipment sections. EPA/HEPA Filter attachment: BTRA frame and rails. /ULPA Installation: Supply air from the unit ducted to the outside. Suction of room where the unit is located. Vertical (purifier 5 with wheels) or horizontal configuration. HIGH Fan B TEMPERA- Plug&Play unit with EC fans and speed regulation 10-100% by means of potentiometer (optional RC to TURE keep the flow rate constant independently of the filter clogging status). Led indicator: - Filter dirty - Fan status - UV lamp (optional) ON/OFF switch: - For the unit - For the UV lamp (optional) Advantatges 6 Depending on the installation of the equipment, it can operate in three different modes of operation: EQUIP- MENTS 1. Unit to generate room depression that isolates the cabin: Extracts and expels clean air to prevent the spread of 7 viruses, bacteria and aerosols outdoor ( requires exhaust duct mouth in purifier drive). Installation mode: Air supply from the unit ducted to the outside. Suction from room where unit is located. MOTORS AND 2. Unit for recirculation and cleaning of room air: To avoid proliferation and spread of viruses, bacteria and aero- TURBINES sols without the need to connect to ducts. Installation mode: Air supply from the unit directly to the room (possi- bility of MIFV 1-4 way accessory for supply through simple defection grid on 1,2,3 or 4 sides). Room suction where the unit is located. 8 3. Unit for generating room overpressure: Clean air supply without the presence of viruses, bacteria or aerosols. Installation mode: Supply of air from the unit directly into the room (possibility of MIFV 1-4 way accessory for im- ADSOR- pulse through single deflection grid with 1,2,3 or 4 sides). Suction conducted from outside the premises. TION AND DEODO- RIZATION Venfilter 9 Tel +34 937 862 607 Fax +34 937 862 493 [email protected] 183 INTER- www.venfilter.com NATONAL REGU- LATION
0 Equipments Absolute filtration HEPA H13-H14 They have a 99.95% filtration efficiency under the INFORMA- Composition standard EN1822 with particle sizes between 0.15 and TION 0.3 μm. The transmission of viruses takes place as Drive plenums usual by means of two types of droplets: large (>10 1 For the vertical range there are μm) and small (>5 μm), resilient in the environment. modules that allow the drive through In this cubicle you would eliminate almost entiretly PRE- .by simple delection air grids the first particle transmission mechanism attached to FILTERS saliva droplets. The absolute filters with a large filtering surface 2 (292mm depth) have a much higher particle reten- tion capacity than low depth filters, reducing notably PAINTING their maintenance requirements and improving their BOOTHS amortization. 3 ePM1 Filtration 80%/F9 COMFORT ePM1 Filtration 70%/F8 PRODUCTS According to ISO 16890, these filters have a 80% filtra- tion efficiency against particles of 1 μm, significantly 4 reducing the transmission of viruses, bacteria and aerosols attached to the saliva droplets. EPA/HEPA /ULPA Active Carbon Filtration As a complement to air purification, the gas filters 5 with chemical absorbent are capable of eliminating odours by adsorption of gases such as hydrogen HIGH sulfide, dimethyl sulfide mercaptans, nitrogen TEMPERA- oxides, formaldehydes, VOCs, formaldehyde, ethylene, chlorine ammonia, mercury TURE Support Ultraviolet lamps 6 The vertical range incorporates UVC radiation inactivates and inhibits replication of wheels to facilitate moving the unit. the nucleic acids (DNA and RNA) of microorganisms EQUIP- At the horizontal range you can (viruses, bacteria, etc.). The absorption of a very MENTS choose from suspended or fixed high energy in a wave length of 253nm generates equipment irreversible damage in the structure of nucleic 7 acids and proteins at the molecular level (Ashrae Fundamentals, Ch62,) Ultraviolet and surface MOTORS treatement AND EC Fans EC technology in plugfan fans with built-in engine, TURBINES fully implanted in the HVAC European market represents a competitive advantage in terms of 8 efficiency, consumption, sound level and regulation, compared to any other type of system ADSOR- TION AND ePM pre-filter 10-50% DEODO- The installation of an ePM10-50% pre-filter allows the protection of RIZATION the equipment’s interior components, extending its life and improving the efficiency of UV lamps 9 Venfilter INTER- NATONAL Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com REGU- 184 LATION
Equipments 0 Codification V/H 6000 H13 CG INFORMA- TION UPA Range: Flow Efficiency Germicidal Model V: Vertical m3/h CA/F7 ePM1 50% chamber 1 H: Horizontal Configuration F8 ePM1 70% PRE- F9 ePM1 80% FILTERS H13/H14 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE Vertical configuration Horizontal configuration 6 References EQUIP- MENTS 1st Stage 1st Stage 2nd Stage 2nd Stage 3rd Stage 3rd Stage No. of filters No. of filters No. of Filters No. of Filters No. of Filters No. of Filters References Model AxBxC (mm) 287x592x48 592x592x48 287x592x292 592x592x292 305x610x292 610x610x292 Weight Kg UxP Stock 7 82 1 F UPA-H-1500 UPA-AIR 474x1714x704 1 1 1 1 UPA-H-3000 UPA-AIR 754x1714x704 1 UPA-H-4500 UPA-AIR 754x1714x1029 1 1 1 2 1 125 1 F MOTORS UPA-H-6000 UPA-AIR 754x1814x1334 2 1 2 2 165 1 F AND UPA-H-7500 UPA-AIR 754x2044x1659 2 2 2 1 11 225 1 F TURBINES UPA-V-3000 UPA-AIR 1714x754x704 2 1 UPA-V-4500 UPA-AIR 1714x754x1029 1 1 1 2 22 UPA-V-6000 UPA-AIR 1814x754x1334 2 1 2 2 UPA-V-7500 UPA-AIR 2044x754x1659 2 2 2 22 275 1 F 2 1 8125 1 F 11 165 1 F 22 225 1 F 22 275 1 F ADSOR- TION AND DEODO- *UxP Units per box RIZATION *Stock F: Manufacture, S: Stock, SL: Limited Stock Venfilter 9 Tel +34 937 862 607 Fax +34 937 862 493 [email protected] 185 INTER- www.venfilter.com NATONAL REGU- LATION
0 Equipments INFORMA- Accesories TION - UPA-MIFV: Frontal supply module with 1,2,3 or 4-way single deflection grid. 1 - UPA-MAFV: Suction module for overpressure operation. - UPA-MHS: System for equipment suspension (Horizontal Range) PRE- - UPA-RC: Flow regulator (to maintain constant flow) FILTERS - UPA-CG: Accessory for UVC germicidal lamps. 2 Suction/Supply Module (Optional for vertical range) PAINTING - MAFV: Suction BOOTHS 1V 2V 3 - MIFV: Supply COMFORT PRODUCTS 3V 4V 4 Dimensions EPA/HEPA References A B C /ULPA UPA-H-1500 474 704 274 5 UPA-H-3000 754 704 274 UPA-H-4500 754 1029 274 HIGH UPA-H-6000 754 1334 334 TEMPERA- UPA-H-7500 754 1659 334 TURE Technical data 6 Model Flow Nominal Maximum Supply Sound level Fan Effective (m3/h) pressure pressure voltage (V) dB(A) (kW) radiation EQUIP- UPA-H-1500 available (Pa) available (Pa) 49 power (W) MENTS UPA-H-3000 1500 230V 50/60Hz 1Ph 53 (1x) 0.75 UPA-H-4500 3000 200 500 230V 50/60Hz 1Ph 54 (1x) 1,27 102 7 UPA-H-6000 4500 200 300 400V 50/60Hz 3Ph 59 (1x) 1,72 153 UPA-H-7500 6000 200 400 400V 50/60Hz 3Ph 56 (1x) 2,95 207 MOTORS UPA-V-3000 7500 200 650 400 50/60Hz 3Ph 53 (1x) 2,7 264 AND UPA-V-4500 3000 200 400 230V 50/60Hz 1Ph 54 (1x) 1,27 352 UPA-V-6000 4500 200 300 400V 50/60Hz 3Ph 59 (1x) 1,72 153 TURBINES UPA-V-7500 6000 200 400 400V 50/60Hz 3Ph 56 (1x) 2,95 207 7500 200 650 400 50/60Hz 3Ph (1x) 2,7 264 8 200 400 352 ADSOR- Nominal and maximum available pressure with G4 + H13 filtration (c2 configuration). TION AND Sound levels calculated with G4 + H13 filtration (c2 configuration). DEODO- RIZATION Venfilter 9 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com INTER- 186 NATONAL REGU- LATION
Equipments 0 Bag in / Bag out INFORMA- TION Mounting parts 1 Hermetic filter unit for safe, contamination-free filter change, designed for applications with safety demands, in PRE- zones with contaminated air (particles, microorganisms, FILTERS molecules), environments that can adversely affect the operator’s safety. Suited for the pharmaceutical, 2 biotechnology, chemical industries, hospitals, biosafety laboratories, facilities for animals. PAINTING BOOTHS Technical features 3 Type: Hermetic modular filter unit for filter change without contamination, designed for applications with safety demands. COMFORT Construction: Hermetic welded steel, continuous welding, safety cover. PRODUCTS Finish: White epoxy paint (RAL 9010) and oven dried. Available in stainless steel. 4 Filters: HEPA/ULPA filters type Poliven or Astroven with a depth of 292 mm, Carbon filters Poly-carb with a depth of 292mm and Quebraven or EPA/HEPA Varipleat type filters of 98 mm depth. /ULPA Filter assembly: Fast filter securing through the lever system, equipped with a “double safety” on both the clampling frame and the door: 5 Impossible to fasten the filter if it is not placed correctly and impossible to close the door if the filter is not fastened to the frame. HIGH Connection: Pre-drilled rectangular flanges. TEMPERA- Options: Stainless steel, configuration for ATEX environments. Many options are available regarding installation configuration. Please ask TURE our experts. 6 Advantages EQUIP- - Secure filter change, no risk of contamination. MENTS - Configuration according to requirements. A wide range of containers with various options is offered. Individual or pos- 7 sibility of various stages of filtration in just one container. - Side or top/bottom air inlet/outlet plenums available. MOTORS - Filter replacement procedure manual. AND - ATEX version available. TURBINES Accessories 8 - Safe changing bag with sealed O-ring - Safety bags with O-ring and arm protection ADSOR- - Connection ducts 1-6 in parallel for high flow rates TION AND - Analog pressure gauge integrated in console DEODO- - Support table for filter change RIZATION - Inspection records - Filter scanning system 9 Venfilter [email protected] 187 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 REGU- LATION
0 Equipments Filter placement Support table INFORMA- Equipment with plenums Filter fastening Filter leak test TION Door opening Filter 1 Bag securing O-ring inspection Scanning record PRE- FILTERS 188 Pressure drop Aerosol control injection port 2 for scanning PAINTING Pressure gauge console BOOTHS Venfilter [email protected] 3 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 0 Module configuration system INFORMA- TION Model Filter size (mmxmm) 1 CCH1 610x610 PRE- FILTERS CCH2 305x610 2 * 610 is always the front measurement. PAINTING Model Pre-filter Filter BOOTHS Height: 98mm Height: 292mm F 3 PF+F 0 1 F+F 1 1 COMFORT PF+F+F 0 2 PRODUCTS 1 2 4 FILTER 292 FILTER 98 + FILTER 292 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS Accessories References 7 Reference Description MOTORS CCH/CHANGE Bag in/ Bag out kit + adjustment o-ring AND CCH/CHANGE-CB Bag in/ Bag out kit with arm guard + adjustment o-ringe TURBINES CCH/SCAN-POINTS System for scanning the filter by points CCH/LOCAL-SCAN Point filter scanning system 8 CCH/PRESSURE GAUGE Analog pressure gauge integrated in console CCH/SUPPORT Support table for maintenance changes CCH / REGISTER-DOOR Door inspection record ADSOR- TION AND CCH/REGISTER-FILTER Visual filter inspection register DEODO- RIZATION CCH / TEST-GASKETS Checking the seal on the filter gasket 9 Venfilter Tel +34 937 862 607 [email protected] 189 INTER- Fax +34 937 862 493 www.venfilter.com NATONAL REGU- LATION
0 Equipments INFORMA- Configuration with FILTER 610mm TION 3200 6400 9600 1 [email protected] PRE- www.venfilter.com FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 190 Venfilter Tel +34 937 862 607 EPA/HEPA Fax +34 937 862 493 /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 16000 19200 0 12800 INFORMA- TION 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 191 INTER- www.venfilter.com NATONAL REGU- LATION
0 Equipments INFORMA- Configuration with FILTER 305mm TION 1600 1 3200 4800 PRE- FILTERS 192 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com 2 Fax +34 937 862 493 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Equipments 8000 0 6400 INFORMA- TION 19600 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 193 INTER- www.venfilter.com NATONAL REGU- LATION
0 Equipments INFORMA- References TION Pre-filter 1 Reference Dimensions Classification Classification Filtering Nominal Initial (BxHxP) Surface Flow Pa PRE- QME61030598G4 EN779 ISO16890 (m3/h) FILTERS QME61061098G4 (m2) 2340 45 VPLPL122404F7 610x305x98 G4 ePM10 50% 0,51 5130 45 2 VPLPL242404F7 610x610x98 G4 ePM10 50% 1,05 1600 90 PVGV122412.4F9 305x610x98 F7 ePM1 55% 5,8 3200 90 PAINTING PVGV242412.8F9 610x610x98 F7 ePM1 55% 11,6 2250 160 BOOTHS 305x610x292 F9 ePM1 80% 14 4500 160 610x610x292 F9 ePM1 80% 28 3 Reference Dimensions Classification Filtering Nominal Initial COMFORT (BxHxP) EN1822 Surface Flow Pa PRODUCTS AVGVPP122411H14 (m3/h) AVGVPP242411H14 305x610x292 H14 (m2) 1330 280 4 610x610x292 H14 12,48 2680 280 PV122412.4H14 305x610x292 H14 25,17 1600 280 EPA/HEPA PV242412.10H14 610x610x292 H14 3200 280 /ULPA 20 40 5 Reference Dimensions Carbon ºC MAX % Weight HIGH CAF122412 (BxHxP) Volume Recommended (Kg) TEMPERA- CAF242412 45 relative humidity 305x610x292 10 45 18 TURE 194 610x610x292 20 30-70 30 30-70 6 Venfilter [email protected] EQUIP- Tel +34 937 862 607 www.venfilter.com MENTS Fax +34 937 862 493 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Equipments Dimensions 0 Filtration ceiling INFORMA- TION Mounting parts For 66 mm filters 1 Filtration ceilings with plenum for replaceable HEPA/ PRE- ULPA filters, type Laminarven, for a correct air diffusion FILTERS in operating theaters with laminar flow. 2 Technical features PAINTING Type: Diffuser terminal unit for ceiling installation, for final filtration in BOOTHS operating theaters. Construction: Tight welded electro-galvanised steel, white epoxy paint 3 (RAL 9010) and, oven dried. Air inlet: Side or top according to project requirements. The standard COMFORT version is manufactured with side entry. PRODUCTS Installation: Handles to fasten it allowing a fast and easy mounting. Filters: Laminarven type with depths of 66, 69 mm in the (standard 4 version). 80 mm in filters with gel seal. Control: Connection filted as a standard in the structure. EPA/HEPA Options: /ULPA - Plenum, structure and grid in stainless steel. - Tight receptacle to place the lamp; position as per project needs. 5 - Possibility to build the plenum for placement of filters with gel seal. - Protective grids in steal with oven-dried white epoxy point RAL9010. HIGH - Protective screen made of nylon fabric tensed over the frame. TEMPERA- Advantages TURE - Smooth coating, easy cleaning of the diffuser grid. 6 - Internal centring parts for the filters and fasteners to place the filter within the structure. EQUIP- - Replaceable Hepa or Ulpa Filter. MENTS - Removal of the filter without altering the tightness of the roof. DOP connections and Pressure Drop. 7 MOTORS AND TURBINES Filter fastener DOP measurement Integrity test probe 8 Side view Fixings Air outlet ADSOR- [email protected] TION AND Venfilter www.venfilter.com DEODO- Tel +34 937 862 607 RIZATION Fax +34 937 862 493 9 195 INTER- NATONAL REGU- LATION
0 Equipments INFORMA- TION 1 References PRE- Reference Model Dimensions Total Filter BxHxP Filter BxHxP Flow Flow Sections Suspension Panel for UxP Stock FILTERS BxHxP Surf. Qty. (mm) Qty. (mm) m3/h m3/h points surgery ** (m2) 2 at 0,30 at 0,25 18 lamp 1F 4 18 (*) 1F 4 m/s m/s 18 YES 1F 10 2 10 YES 1F 2 VENHOSP.TYPE1P VENHOSP 2552x400x1332 3,4 8 915x610 4 1220x305 2813 2344 2 12 YES 1F VENHOSP.TYPE2P VENHOSP 1963x400x1942 3,7 10 915x610 2 2 12 YES 1F VENHOSP.TYPE3P VENHOSP 2552x400x1963 5,01 14 1220x610 2 610x610 3214 2679 3 12 YES 1F 915x610 YES 1220x610 2 915x610 4420 3683 YES 1220x610 4 PAINTING VENHOSP.TYPE4P VENHOSP 2552x400x2594 6,62 1220x610 2 6028 5023 BOOTHS VENHOSP.TYPE5P VENHOSP 3225x400x2512 8,05 915x610 7635 6362 VENHOSP.TYPE6P VENHOSP 3200x400x3200 10 610x610 9644 8037 3 VENHOSP.TYPE7P VENHOSP 3225x400x3733 11,96 610x305 11654 9711 PERFORATED GRIDS COMFORT Reference Model Dimensions Total Filter BxHxP Filter BxHxP Flow Flow Sections Suspension Panel for UxP Stock PRODUCTS BxHxP surf Units (mm) Units (mm) m3/h m3/h points surgery ** (m2) 2 915x610 4 at 0,30 at 0,25 18 lamp 1F 4 915x610 2 18 (*) 1F 4 4 1220x610 2 m/s m/s 18 YES 1F 10 915x610 2 10 YES 1F VENHOSP.TYPE1S VENHOSP 2552x400x1332 3,4 8 1220x610 2 1220x305 2813 2344 2 12 YES 1F VENHOSP.TYPE2S VENHOSP 1963x400x1942 3,7 10 1220x610 4 2 12 YES 1F 14 1220x610 2 610x610 3214 2679 3 12 YES 1F YES EPA/HEPA VENHOSP.TYPE3S VENHOSP 2552x400x1963 5,01 915x610 4420 3683 YES /ULPA VENHOSP.TYPE4S VENHOSP 2552x400x2594 6,62 6028 5023 5 VENHOSP.TYPE5S VENHOSP 3225x400x2512 8,05 915x610 7635 6362 VENHOSP.TYPE6S VENHOSP 3200x400x3200 10 VENHOSP.TYPE7S VENHOSP 3225x400x3733 11,96 610x610 9644 8037 610x305 11654 9711 NYLON SCREENS HIGH TEMPERA- TURE 6 VENHOSP TYPE 6: The VENHOSP type 6 ceiling with an operational surface of around 10m2 is ideal for “heavy” surgical interventions (orthopaedic, cardiology, etc.) because it offers to the surgical team great relief EQUIP- (recommendation in the“ Guide to air treatment in hospitals” by INCLIMA) used at a speed of 0,25m/s to 0,30 MENTS m/s in a surgery of 45 m2. VENHOSP TYPES 3 and 4: The 3 and 4 TYPES with injection surfaces of 5 and 7 m2 respond to the needs in 7 “lighter” surgical interventions. VENHOSP TYPE 3: It guarantees the minimum index required by standard NF S90-351 in a surgery of 40 m2 MOTORS functioning at an average speed of 0,30m/s. AND VENHOSP TYPE 1: In ultra-sensitive services (third degree burns, patients with immune system disorders, etc.). It’s specifically designed to protect the bed. TURBINES *UxP *Stock 8 Units per box F: Manufacturer, S: Stock, SL: Limited Stock ADSOR- Venfilter TION AND DEODO- Tel +34 937 862 607 [email protected] RIZATION Fax +34 937 862 493 www.venfilter.com 196 9 INTER- NATONAL REGU- LATION
Equipments 0 Technical Documentation INFORMA- TION Filter layout and lamp panel position on request. 1 TYPE 1 PRE- FILTERS 1332 mm Filter measure: 610x610 mm 2 Filter measure: 915x610mm 2552 mm Filter measure: 1220x610 mm PAINTING Filter measure: 305x305 mm BOOTHS TYPE 2 Filter measure: 610x305 mm Filter measure: 915x305 mm 3 1942 mm Filter measure: 1220x305 mm Lamp panel: COMFORT 1963 mm On request, measures from 420x420 to PRODUCTS 595x595 mm. TYPE 3 In relation to filters according to scheme. 4 1963 mm 197 EPA/HEPA /ULPA 2552 mm 5 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com HIGH Fax +34 937 862 493 TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
0 2594 mmEquipments Filter measure: 610x610 mm INFORMA- 2512 mm TYPE 4 2552 mm Filter measure: 915x610mm TION TYPE 5 3225 mm TYPE 7 3225 mm Filter measure: 1220x610 mm 1 Filter measure: 305x305 mm 198 Filter measure: 610x305 mm PRE- Filter measure: 915x305 mm FILTERS Filter measure: 1220x305 mm 2 Lamp panel: On request, measures from 420x420 to PAINTING 595x595 mm. BOOTHS In relation to filters according to scheme. 3 3733 mm COMFORT Venfilter [email protected] PRODUCTS Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Search
Read the Text Version
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 76
- 77
- 78
- 79
- 80
- 81
- 82
- 83
- 84
- 85
- 86
- 87
- 88
- 89
- 90
- 91
- 92
- 93
- 94
- 95
- 96
- 97
- 98
- 99
- 100
- 101
- 102
- 103
- 104
- 105
- 106
- 107
- 108
- 109
- 110
- 111
- 112
- 113
- 114
- 115
- 116
- 117
- 118
- 119
- 120
- 121
- 122
- 123
- 124
- 125
- 126
- 127
- 128
- 129
- 130
- 131
- 132
- 133
- 134
- 135
- 136
- 137
- 138
- 139
- 140
- 141
- 142
- 143
- 144
- 145
- 146
- 147
- 148
- 149
- 150
- 151
- 152
- 153
- 154
- 155
- 156
- 157
- 158
- 159
- 160
- 161
- 162
- 163
- 164
- 165
- 166
- 167
- 168
- 169
- 170
- 171
- 172
- 173
- 174
- 175
- 176
- 177
- 178
- 179
- 180
- 181
- 182
- 183
- 184
- 185
- 186
- 187
- 188
- 189
- 190
- 191
- 192
- 193
- 194
- 195
- 196
- 197
- 198
- 199
- 200
- 201
- 202
- 203
- 204
- 205
- 206
- 207
- 208
- 209
- 210
- 211
- 212
- 213
- 214
- 215
- 216
- 217
- 218
- 219
- 220
- 221
- 222
- 223
- 224
- 225
- 226
- 227
- 228
- 229
- 230
- 231
- 232
- 233
- 234
- 235
- 236
- 237
- 238
- 239
- 240
- 241
- 242
- 243
- 244
- 245
- 246
- 247
- 248
- 249
- 250
- 251
- 252
- 253
- 254
- 255
- 256
- 257
- 258
- 259
- 260
- 261
- 262
- 263
- 264
- 265
- 266
- 267
- 268
- 269
- 270
- 271
- 272
- 273
- 274
- 275
- 276
- 277
- 278