Adsortion and desodorization 0 CARB ORGANIQUES INFORMA- TION Active Carbon Filters 1 It is a thermally activated anthracite carbon. In multi- bed systems, it acts as a refining filter to remove high PRE- molecular weight compounds. FILTERS Technical features 2 Toluene adsorption capacity at 10ppmv:> 14% by weight. PAINTING Benzene adsorption capacity at 100ppmv::> 12% by weight. BOOTHS Density: 480 ± 30 Kg / m3 Pellet diameter: 3 or 4mm 3 Hardness:> 97% Humidity: <4% COMFORT Gas removal process: Adsorption. PRODUCTS Contaminants: Hydrocarbons, chlorine, volatile organic compounds and siloxanes. 4 Relative humidity: 10-95% Efficiency: Up to 99% EPA/HEPA Temperature: -20ºC to 50ºC /ULPA Advantages 5 - Does not contain impregnation. HIGH - Large surface area TEMPERA- - Greater gas adsorption capacity. TURE Packaging 6 Available in: - 25Kg bags EQUIP- MENTS Quality Control 7 Subject to the following quality controls: - H2S capacity MOTORS - Moisture content AND Media handling TURBINES Installers are recommended to wear dust masks, goggles, and rubber gloves. 8 Waste generated by handling must be disposed of and recycled according to local, state and national regulations. Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 249 INTER- www.venfilter.com NATONAL REGU- LATION
0 Adsortion and desodorization INFORMA- CARB ORGANIQUES MAX TION Active Carbon Filters 1 Consists of an anthracite origin virgin Carbon with a grade PRE- of CTC 60, wich is thermally activated to obtain a large FILTERS surface area and a high gas removal capacity. Contains no impregnates. Is designed to eliminate hydrocarbons, 2 chlorine and volatile organic compounds (VOC's). In multiple-bed systems CARB OGANICOS acts as a PAINTING refining filter to eliminate VOC's with high molecular BOOTHS weight structure. 3 Technical features volatile organic COMFORT Surface area : 1050 m2/g PRODUCTS CTC: 60% in weight Density: 450 ± 30 Kg/m3 4 Pellet diameter: 3,4 mm Mechanical strength: >97% EPA/HEPA Humidity: 4% /ULPA Gas removal process: Adsorción Pollutants: Hydrocarbons, chlorine, 5 compounds and siloxanes Humidity: 10-95% HIGH Temperature: -20ºC till 50ºC TEMPERA- Efficiency: Up to 99,9% TURE Advantages 6 - High capacity - Low dust EQUIP- MENTS Packaging 7 Available in: - Bags of 25Kg. MOTORS AND Quality control TURBINES Subject to the following quality controls: - Titratable Phosphoric Acid 8 - Moisture Content - Apparent Density ADSOR- TION AND Media handling DEODO- RIZATION Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to 9 local, state and national regulations. INTER- Venfilter [email protected] NATONAL Tel +34 937 862 607 www.venfilter.com 250 Fax +34 937 862 493 REGU- LATION
Adsortion and desodorization 0 CARB FORMALDEHYDES INFORMA- TION Active Carbon Filters 1 It is a granulated product presented as cylindrical pellets based on natural clays which have been extruded together PRE- with potassium permangante (KMnO4) as active principle. FILTERS The KMnO4 in CARB FORMALDEHYDES is responsible for the removal of the target gases, principally ethylene and 2 formaldehyde, thanks to a chemical reaction on the active surface of the absorbent. PAINTING BOOTHS Technical features 3 Ethylene absorption capacity: Up to 4.5% (L/Kg media) Ethanol absorption capacity: Up to 20% (w/w) COMFORT HCHO absorption capacity: Up to 8% (w/w) PRODUCTS Density: 840 ± 20 Kg/m3 Pellet diameter : 3,4 mm 4 Radial crush strength: 3 KgF LOA (Loss On Attrition): <5% EPA/HEPA Humidity: 20% /ULPA Target pollutants: Ethylene, Formaldehyde and VOCs Humidity: 10-95% 5 Temperature: -20ºC till 50ºC Efficiency: Up to 99,9% HIGH TEMPERA- Application TURE - Extraordinary ethylene elimination and air cleaning in fresh produce transport and/or storage enclosures, thus extending the post-harvest life 6 of the products. - Effective removal of other light odorous volatile organic compounds EQUIP- (VOCs), such as short-chain alcohols or formaldehyde (HCHO). MENTS Packaging 7 Available in: MOTORS - Bags of 25Kg. AND Quality control TURBINES Subject to the following quality controls: 8 - Ethylene absorption capacity and efficiency - Moisture Content ADSOR- TION AND Media handling DEODO- RIZATION Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to 9 local, state and national regulations. Venfilter [email protected] 251 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 REGU- LATION
0 Adsortion and desodorization [email protected] www.venfilter.com INFORMA- CARB ACIDS TION Active Carbon Filters 1 It is an activated carbon of high purity and large surface PRE- area. A chemical impregnated neutralizes acidic FILTERS compounds with effectiveness. 2 Technical features PAINTING Specific surface: 1050 m2/g BOOTHS H2S Removal capacity: Up to 26% in weight 0.14 gr/cc Density: 540 ± 30 Kg/m3 3 Pellet diameter: 4mm Mechanical strength: 97% COMFORT Humidity: 15% PRODUCTS Ignition temperature: 280 ºC/ 536ºF Gas removal process: Chemisorption 4 Target pollutants: H2S, SO2, Mercaptanos, Ácidos CI2 Humidity(%): 10-95 EPA/HEPA Temperature: -20ºC till 50ºC /ULPA Efficiency(%): Up to 99,9 5 Advantages HIGH - Broad spectrum of pollutants removal. TEMPERA- - Higher loading capacity = longer life. - Resistance to high moisture content. TURE Application 6 It is suitable for a wide range of applications: waste water EQUIP- treatment plants, corrosion control, food processing, MENTS waste handling, museums, archives, datacenters and more. 7 Packaging MOTORS AND Available in: - Bags of 25Kg (55Ibs). TURBINES Quality control 8 Subject to the following quality controls: ADSOR- - H2S Capacity TION AND - Moisture Content DEODO- RIZATION Media handling 9 Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to INTER- local, state and national regulations. NATONAL Venfilter REGU- Tel +34 937 862 607 LATION 252 Fax +34 937 862 493
Adsortion and desodorization 0 CARB AMMONIA INFORMA- TION Active Carbon Filters 1 It is a bituminous active carbon impregnated with phosphoric acid. Typical applications include odor and PRE- irritants absorption derived from sewer system, fertilizers, FILTERS printers, cleaners, urine and fish processing. 2 Technical features PAINTING Specific area: 1050 m2/g BOOTHS NH3 Removal capacity: Up to 10% in weight Density: 580 ± 30 Kg/m3 3 Pellet diameter: 3 o 4 mm Mechanical strength: >98% COMFORT Humidity: 15% PRODUCTS Gas removal process: Chemisorption Contaminants: 4 - Ammonia, amines and volatile organic compounds. - Dimethylmine, isobuthylamine, t-butyl amine, di-n- EPA/HEPA propylamine, Isopropyl amine, Tetramethyl, n-butyl /ULPA amine, Ethylamine, Methylamine, Triethylamine, Cyclo exylamine, Ethylenediamine, Methylethylamine, 5 Trimethylamine, Diethylamine, n-Propylamine, toluidina, Hexamethylendiamine, Sec-butylamine y Phenylethylamine. HIGH Humidity: 10-95% TEMPERA- Temperature: -25ºC till 50ºC Efficiency: Up to 99,9% TURE Advantages 6 - Specific for basic gases. EQUIP- - Combined adsorption on different compounds. MENTS Packaging 7 Available in: MOTORS - Bags of 25Kg. AND Quality control TURBINES Subject to the following quality controls: 8 - Titratable Phosphoric Acid - Moisture Content ADSOR- TION AND Media handling DEODO- RIZATION Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to 9 local, state and national regulations. Venfilter [email protected] 253 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 REGU- LATION
0 Adsortion and desodorization INFORMA- CARB MIXED TION Active Carbon Filters 1 It is a high purity, large surface activated carbon. PRE- The impregnated chemical principle neutralizes acidic FILTERS compounds very effectively 2 Technical features PAINTING CARB MIXTO CARB ISORB CARB Units BOOTHS MAX ORGANIQUES m2/g Specific surface % in weight 3 16 1052 H2S Removal % in weight COMFORT Capacity 6 60 PRODUCTS % in weight SO2 Removal 2,5 430 ± 30 4 Capacity % in weight 8 3,4 EPA/HEPA NO Removal >97 % in weight /ULPA Capacity 4 4 % in weight 5 NO2 Removal 840 ±20 Adsorption Capacity g/l HIGH 2,3 o 4 10-95 mm TEMPERA- HCHO Removal 4 kg of strength -20ºC till 50ºC % Capacity % TURE 15 Up to 99,9 CCI4 Removal Chemisorption % 6 Capacity ºC Density 10-95 % EQUIP- -20ºC till 50ºC MENTS Pellet diameter Up to 99,9 7 Hardness MOTORS Humidity AND Gas removal TURBINES process Humidity 8 Temperature ADSOR- TION AND Efficiency DEODO- RIZATION Advantages 9 - Reduces the number of pellets needed - Changes color as it is worn INTER- NATONAL Application REGU- - Corrosion control LATION - Odor control Packaging Available in: - Bags of 25Kg. Quality control Subject to the following quality controls: - H2S Capacity - Moisture Content Media handling Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to local, state and national regulations. Venfilter 254 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com
Adsortion and desodorization 0 CARB ISOTOPES INFORMA- TION Active Carbon Filters 1 It is based on activated carbon of the highest purity and impregnated with 4% KI to provide excellent adsorption PRE- properties. FILTERS It is designed to remove mercury and iodine compounds. It is also effective in removing formaldehyde and organic 2 aldehydes, sulfur compounds, mercaptans, DMDS, SO2, and H2S. PAINTING BOOTHS Technical features 3 Surface area: 1050 m2 / g Methyl mercaptan adsorption capacity: Up to 17% by weight COMFORT Dimethyl sulfide adsorption capacity: Up to 23% by weight PRODUCTS SO2 adsorption capacity: Up to 13% by weight H2S adsorption capacity: Up to 19% by weight 4 Density: 580 ± 30 Kg / m3 Pellet diameter: 3 or 4 mm EPA/HEPA Hardness: 97% /ULPA Humidity: 15% Gas removal process: Chemisorption 5 Contaminants: - Mercury HIGH - Radioactive iodine and organic iodine compounds TEMPERA- - Formaldehyde and organic aldehydes - Sulfur compounds, mercaptans, DMDS, SO2 and H2S TURE Humidity (%): 10-95 Temperature: -20ºC to 50ºC 6 Performance: Up to 99.9 EQUIP- Advantages MENTS - Wide range of gas adsorption. 7 - High load capacity = long life. - Avoid side effects caused by the toxic properties of mercury. MOTORS AND Packaging TURBINES Available in: - 25Kg bags 8 Quality control ADSOR- TION AND Subject to the following quality controls: DEODO- - KI content RIZATION - Moisture content 9 Media handling Installers are recommended to wear dust masks, goggles, and rubber gloves. Waste generated by handling must be disposed of and recycled according to local, state and national regulations. Venfilter [email protected] 255 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 REGU- LATION
0 Adsortion and desodorization INFORMA- CARB FORMALDEHYDES TION (SPHERE) Active Carbon Filters 1 Spherical Alumina based media. Impregnated with PRE- Potassium Permanganate during manufacturing. FILTERS Uses the combined action of physical and chemical processes to control gas emissions. Oxidized gases are 2 converted into harmless products such as CO2, water and salts. PAINTING Is designed to efficiently eliminate pollutants such as acidic BOOTHS gases, Nitrogen and Sulphur containing compounds, and low molecular weight volatiles. 3 Technical features COMFORT H2S Removal capacity: 14% in weight PRODUCTS SO2 Removal capacity: 7% en peso NO Removal capacity: 5% en peso 4 NO2 Removal capacity: 21% en peso HCHO Removal capacity: 2,5 en peso EPA/HEPA Density: 760 ± 30 Kg/m3 /ULPA Pellet diameter: 3-5 mm Humidity: 25% (max.) 5 Attrition: 5% (max.) Crush strength: 2 KgF HIGH Humidity: 10-95% TEMPERA- Temperature: -20ºC till 50ºC Efficiency: 99.5% min TURE Advantages 6 - Wide spectrum of gas adsorption. - Best ''polishing'' method to comply with the stringiest outlet gas concentrations. - Higher loading capacity - Visual indicator when product is consumed Application EQUIP- It is recommended for a wide range of applications such as waste water MENTS tratment plants, pulp and paper plants, airports, chemical plants, refineries, exhaust gases and more. 7 Packaging MOTORS AND Available in: - Bags of 22.7Kg. TURBINES Quality control 8 All Batches are Inspected according to our ISO 2015 procedures, including ADSOR- active ingredients content, humidity, bulk density, mechanical strenght and TION AND abrasion. DEODO- RIZATION Media handling 9 Installers are recommended to wear dust masks, goggles and ruber gloves. Waste generated from handling must be disposed of and recycled according to local, state and national regulations. INTER- 256 Venfilter [email protected] NATONAL Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 REGU- LATION
Adsortion and desodorization 0 MIXED CARB SPHERE INFORMA- TION Active Carbon Filters 1 Es una mezcla de CARB FORMALDEHYDES/E y carbón activado CARB ORGANIQUES. Esta mezcla ofrece en (%): PRE- 70-30,50-50 o 30-70, con una densidad a granel 667,605 o FILTERS 543 Kg/m3. 2 Technical features PAINTING CARB MIXTO CARB FORMALDEHYDES CARB ORGANIQUES Units BOOTHS SPHERE 1052 m2/g % in weight 3 Specific surface 60 % in weight COMFORT H2S Removal 16 430 ± 30 PRODUCTS capacity 6 % in weight 2,5 3,4 4 SO2 Removal 8 >97 % in weight capacity 4 EPA/HEPA 4 % in weight /ULPA NO Removal 840 ±20 Adsorption capacity % in weight 5 2,3 o 4 10-95 NO2 Removal -20ºC till 50ºC g/l HIGH capacity mm TEMPERA- up to 99 % HCHO Removal % TURE capacity % 6 CCI4 Removal ºC capacity % EQUIP- Density MENTS Pellet Diameter 7 Hardness 4 kg of f/cm MOTORS AND Humidity 15 TURBINES Gas removal Chemisorption process 10-95 8 Humidity ADSOR- Temperature -20ºC till 50ºC TION AND DEODO- Efficiency up to 99 RIZATION Advantages 9 The main advantage is that both absorbers complement each other when treating different pollutants. INTER- NATONAL Application REGU- - Corrosion control LATION - Odor control Packaging Available in: - Bags of 25Kg. Quality control - H2S Capacity - Moisture content Media handling Installers are recommended to use dust masks, safety goggles and rubber gloves. Waste generated from handling must be disposed of and recycled according to local, state and national regulations. Venfilter [email protected] 257 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
0 Adsortion and desodorization INFORMA- CARB MAX TION Active Carbon Filters 1 Combines a mixture of physical and chemical processes to PRE- control gas emissions. Oxidized gases are converted into FILTERS harmless products such as CO2, water and salts. It is designed to eliminate efficiently pollutants such as acidic gases, N- and 2 S- containing compounds and low molecular weight compounds. Brings improved physical properties such as hardness and resisrance against fully saturated atmospheres. Its exhaustion is easily seen since the colour changes from violet to brownish. PAINTING Technical features BOOTHS H2S Absortption capacity: Up to 16% (w/w) 3 SO2 Absortption capacity: Up to 6% (w/w) NO Absortption capacity: Up to 2,5% (w/w) COMFORT NO2 Absortption capacity: Up to 8% (w/w) PRODUCTS HCHO Absortption capacity: Up to 8% (w/w) Density: 840 ± 20 Kg/m3 4 Pellet diameter: 3 o 4 mm Mechanical strength: 4 Kg de f/cm EPA/HEPA Humidity: 15% /ULPA Target pollutants: H2S, SO2, NO,NO2, Formaldehyde, Ethylene, HCN, Short-chain alcohols, Organic and inorganic 5 acids, Aldehydes, Light VOCs, Methyl and ethyl mercaptan Humidity: 10-95% HIGH Temperature: -20ºC till 50ºC TEMPERA- Efficiency: Up to 99 TURE Application 6 It is especially recommended for a wide range of applications: wastewater treatment plants, pulp and paper plants, airports, EQUIP- chemical plants, refineries, gas venting and more. MENTS Advantages 7 - Wide spectrum of gases absorption. MOTORS - Best polishing method to comply with the stringiest outlet gas concentrations. AND - Higher loading capacity. - Visual indicator when product is consumed. TURBINES - Spent media is landfill disposable. 8 Packaging ADSOR- Available in: TION AND - Bags of 25Kg. DEODO- RIZATION Quality control 9 - H2S absorption capacity ASTM D6646 - Moisture content INTER- NATONAL Media handling REGU- Use the PPE (Personal Protective Equipment) when handling solid chemicals: dust mask, safety goggles and LATION rubber gloves. Waste generated from handling must be disposed of and recycled according to local, state and national regulations. Venfilter 258 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com
Adsortion and desodorization 0 CARB SULFUR INFORMA- TION Active Carbon Filters 1 Combines a premium quality activated carbon with a proprietaty blend of catalytic inorganic phase and metal PRE- oxides, which results in an extraordinary hydrogen FILTERS sulfide (H2S) absorption capacity in oxygen-poor streams. Unlike other medias, H2S is not converted to sulfuric acid 2 (H2SO4), but to elemental sulfur (S), which is accumulated in the carbon micropores. PAINTING BOIN Carb ODR is also a good absorbent for other acidic BOOTHS gases, such as sulfur dioxide(SO2), methylmercaptan and volatile sulfur compounds (VSCs). 3 Technical features COMFORT PRODUCTS H2S Absorption capacity: Up to 50% (w/w) Mechanical strength: 2 KgF 4 Density: 450 ± 30 Kg/m3 LOA (Loss On Attrition): <10% EPA/HEPA Peller diameter: 3, 4 mm /ULPA Humidity: 15-20% Ignition temperature: 420ºC (799 ºF) 5 Target pollutants: H2S, SO2, Methylmercaptan and VSCs Humidity: 10-95% HIGH Temperature: -20ºC till 50ºC TEMPERA- Efficiency: 99.5%min Maximum bed height: 1,5m (optimum height up to 1m) TURE Application 6 Highly effective in the abatement of odour caused by sulfur compounds (in EQUIP- wastewater treatment plants, pump stations, sewage systems...) as long as MENTS the application guideline is respected 7 Packaging MOTORS Available in: AND - Bags of 20Kg. TURBINES Quality control 8 - H2S absorption capacity ASTM D6646 - Moisture content ADSOR- TION AND Media handling DEODO- RIZATION Use the PPE (Personal Protective Equipment) when handling solid chemicals: dust mask, safety goggles and rubber gloves. Waste generated from handling must be disposed of and 9 recycled according to local, state and national regulations. Venfilter [email protected] 259 INTER- Tel +34 937 862 607 www.venfilter.com NATONAL Fax +34 937 862 493 REGU- LATION
0 Adsortion and desodorization INFORMA- Quebraven Galvanized TION Impregnated carbon 1 Active Carbon Filters PRE- FILTERS 2 Panel filter with metal frame with filter media impregna- Dimensions ted with active carbon. For the prefiltration of central air PAINTING treatment, conditioning and ventilation systems for the BOOTHS elimination of gaseous pollutants. 3 Technical features COMFORT Type: Panel filter with metal frame with filter media impreg- PRODUCTS nated with active carbon. Frame: Galvanized steel. 4 Grid: Metallic galvanized on both sides. Filter element: Synthetic media impregnated with activated EPA/HEPA carbon. /ULPA Relative Humidity: 70%. Temperature limit: 55ºC. 5 Advantages HIGH TEMPERA- - Combined particles / molecules filtration. - Low Pressure Dropes. TURE - All dimensions. 6 References Model Dimensions Filtering Nominal Initial Unit UxP* Stock* BxHxP Surface flow (m3/h) Pa Volume EQUIP- Reference QMCA 1F MENTS QMCA 592x287x48 (m2) 1500 125 (m3) 1F QM122402CA QMCA 592x287x98 0.7 1700 195 0.008 1F 7 QM122404CA QMCA 592x592x48 1.1 3000 125 0.016 1F QM242402CA 592x592x98 1.3 3400 195 0.016 MOTORS QM242404CA 2.2 0.034 AND *UxP *Stock TURBINES Units per box F: Manufacture, S: Stock, SL: Limited Stock 8 Venfilter ADSOR- 260 Tel +34 937 862 607 [email protected] TION AND Fax +34 937 862 493 www.venfilter.com DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Adsortion and desodorization 0 Metal Frame activated H Dimensiones INFORMA- Carbon TION B P Active Carbon Filters 1 Filter built using a galvanized steel frame and protected PRE- with a perforated sheet. Designed for the deodorization FILTERS and purification of gaseous pollutants. Some application examples are: In air conditioning machinery, paint booths, 2 air with low concentration of organic solvents, etc. PAINTING Technical features BOOTHS Type: Panel filter with metal frame and activated carbon 3 in pellets. Frame: Galvanized steel or aluminum COMFORT Grille: Galvanized metal on both sides. PRODUCTS Filter element: Activated carbon. Charcoal with impreg- nation. 4 Relative Humidity: 70%. Working temperature: Maximum 55ºC. EPA/HEPA /ULPA Advantages 5 - Combined filtration of particles / molecules. - All dimensions. HIGH - Possibility of manufacturing with all the coals in our catalog. A solution for every problem. TEMPERA- - Non-woven membrane that protects from dust. TURE References 6 Code Model Dimensions Type of (Kg) Filtering UxP Stock Article BxHxP carbon Carbon surface ** EQUIP- CAMM122401GO CAMM CARB-ORGANIQUES 0.016 1F MENTS CAMM122402GO CAMM 287x592x25 CARB-ORGANIQUES 2 0.034 1F CAMM 592x287x50 CARB-ORGANIQUES 5 1F 7 CAMM242401GO CAMM 592x592x25 CARB-ORGANIQUES 7 0.28 1F CAMM242402GO CAMM 592x592x50 CARB-ORGANIQUES 7 0.30 1F MOTORS CAMM162902GO CAMM 390x730x55 CARB-ORGANIQUES 4 0.35 1F AND CAMM163002GO 405x755x51 8 0.35 TURBINES *UxP *Stock Units per box F: Manufacture, S: Stock, SL: Limited Stock 8 Installations Instructions ADSOR- TION AND Installers are recommended to wear a dust mask, goggles and rubber gloves. Waste generated by DEODO- handling must be disposed of and recycled according to local, state and national regulations. RIZATION Venfilter [email protected] 261 9 Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 INTER- NATONAL REGU- LATION
0 Adsortion and desodorization H BP INFORMA- Modules PP12 TION Active Carbon Filters 1 The PP12 Module was developped to provide a quick and PRE- clean granulate replenishment method in Ethylclean FILTERS machines for post harvest applications, and also in air purification systems in commercial and industrial 2 applications. It is V-shaped to reduce air resistance. The filter is 100% PAINTING recyclable. BOOTHS The module can contain any of the granules of the CARB range. 3 Technical features COMFORT PRODUCTS 4 Dimensions LxHxP: 298x296x296. Designed to be placed two, one next to the other, in a width of 60cm. EPA/HEPA Weight (empty): 1.60 Kg /ULPA Volume: 30 liters Material: 100% recyclable polystyrene 5 Packaging: Cardboard box with protective bag in a group of two units. Working temperature: Maximum 55ºC Relative humidity: 20-95%. Depending on the granulate used Color: black HIGH References TEMPERA- Model Coal type Dimensions Volume Weight Coal Total TURE )liters( (empty) weight 298x296x296 weight UxC Stock 6 298x296x296 Kg EQUIP- PP12 CARBACIDOU2 CARB-ACIDS 298x296x296 30 1,6 8,7 10,3 2 F MENTS 298x296x296 12,6 2 F PP12 CARBFORMALDEHYDE CARB- 298x296x296 30 1,6 11 7 PP12 CARBMAX FORMALDEHYDE/E 298x296x296 30 1,6 12,6 14,2 2 F MOTORS CARB-MAX 30 1,6 9,6 11,2 2 F AND 30 1,6 6,9 8,5 2 F PP12 CARBMIXTOU2 CARB MIXED 30 1,6 7,2 8,8 2 F TURBINES PP12 CARBSOUFRE CARB-SOUFRE 8 PP12 CARBORGANIQUES CARB-ORGANIQUES ADSOR- *UxP *Stock TION AND Units per box F: Manufacture, S: Stock, SL: Limited Stock DEODO- RIZATION 262 Venfilter [email protected] Tel +34 937 862 607 www.venfilter.com 9 Fax +34 937 862 493 INTER- NATONAL REGU- LATION
Adsortion and desodorization 0 Flow data INFORMA- TION Front speed Air Flow Flow per air Contact Pressure Drop (m/s) (m3/h) (m3/h) time (s) (Pa) 1 0.25 80 160 0,640 55 PRE- 0,50 160 320 0,320 83 FILTERS 0,66 213 425 0,241 110 0,75 240 480 0,213 128 2 1,00 320 639 0,160 200 1,25 400 799 0,128 275 PAINTING 1,50 480 959 0,107 370 BOOTHS 3 COMFORT PRODUCTS CaidParePssruerseióDnroepninMPPo1d2uPlaoMs oPdPu1le8s Pa 4 Δ P (Pa 70 EPA/HEPA /ULPA 60 5 50 HIGH 40 TEMPERA- 30 TURE 20 6 10 EQUIP- MENTS 0 0 100 200 300 400 500 600 700 800 900 1000 Flow per pair [m3/h[ 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 263 INTER- www.venfilter.com NATONAL REGU- LATION
0 Adsortion and desodorization INFORMA- Modules PP18 TION Active Carbon Filters 1 PRE- The PP18 Module was developped to provide a fast and clean H FILTERS granulate replenishment method in Ethylclean machines, as well as air purification systems in commercial and 2 industrial applications. It is V-shaped to reduce air resistance. The filter is 100% PAINTING recyclable. BOOTHS The module can contain any of the granules of the CARB range. 3 B P COMFORT Technical features PRODUCTS Dimensions LxHxP: 439x296x154. Designed to be placed two, one next to the other, in a 4 width of 60cm. Weight (empty): 1.60 Kg EPA/HEPA Volume: 15 liters /ULPA Material: 100% recyclable polystyrene Packaging: Cardboard box with protective bag in a group of two units. 5 Working temperature: Maximum 55ºC Relative humidity: 20-99%. Depending on the granulate used Color: black References HIGH Model Coal type Dimensions Volume Weight Coal Total UxC Stock TEMPERA- PP18 CARBACIDOU2 CARB-ACIDS 439x296x145 )liters( (empty) weight weight TURE Kg 3,915 6 15 1,6 5,515 2 F 6,73 2 F EQUIP- PP18 CARBFORMALDEHIDO CARB- 439x296x145 15 1,6 5,13 MENTS PP18 CARBMAX FORMALDEHIDSO/E 439x296x145 7,27 2 F 15 1,6 5,67 5,92 2 F 7 CARB-MAX 15 1,6 4,32 4,84 2 F 15 1,6 3,24 MOTORS PP18 CARBMIXTOU2 CARB MIXED 439x296x145 AND PP18 CARBORGANIQUES CARB-ORGANIQUES 439x296x145 TURBINES 8 *UxP *Stock Units per box F: Manufacture, S: Stock, SL: Limited Stock ADSOR- 264 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
Adsortion and desodorization 0 Flow data INFORMA- TION Front speed Air flow Flow per pair Contact Pressure (m/s) (m3/h) (m/3/h) time (s) drop (Pa) 1 0.25 83 0,577 0,50 42 167 0,289 4 PRE- 0,66 83 222 0,217 6 FILTERS 0,75 111 250 0,192 8 1,00 125 334 0,144 9 2 1,25 167 417 0,115 13 1,50 209 501 0,096 18 PAINTING 1,75 250 584 0,082 24 BOOTHS 2 292 668 30 2,25 334 751 0,72 37 3 2,5 376 834 0,064 45 2,66 417 888 0,058 53 COMFORT 444 0,054 58 PRODUCTS 4 CaidParePsrseusrieóDnreonp iMn PoPd1u2lPoas MPPod1u2lePsa EPA/HEPA /ULPA 400 350 5 300 Δ P (Pa 250 HIGH 200 TEMPERA- 150 100 TURE 50 6 0 0 EQUIP- MENTS 200 400 600 800 1000 1200 7 Flow per pair [m3/h[ MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 265 INTER- www.venfilter.com NATONAL REGU- LATION
0 Adsortion and desodorization Dimensions INFORMA- Frame for carbon TION replaceable cartridge 1 Active Carbon Filters PRE- Frame for fitting the active carbon cylinders. FILTERS Technical features 2 Type: Mounting for the cartridges. PAINTING Frame: Galvanized Steel, Stainless Steel or Plastic. BOOTHS Cartridge Fitting system: Fitting of cartridges on the quick bayonet mounting. 3 Advantages COMFORT PRODUCTS - Modular System. 4 References Model Dimensions No. of Unit Volume Weight (Kg) UxP Stock BxHxP Cartridges (m3) * * EPA/HEPA Reference BTC-GV 0.02 3 1 F /ULPA BTC-GV 305x610x75 8 0.03 5 1 F BTCGV1224 610x610x75 16 5 BTCGV2424 HIGH *UxP *Stock TEMPERA- Units per box F: Manufacture, S: Stock, SL: Limited Stock TURE Venfilter 6 266 Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com EQUIP- MENTS 7 MOTORS AND TURBINES 8 ADSOR- TION AND DEODO- RIZATION 9 INTER- NATONAL REGU- LATION
Adsortion and desodorization 0 Replaceable carbon INFORMA- cartridges TION Active Carbon Filters 1 Replaceable carbon cartridges for air entry and exit in PRE- ventilation systems that require imporved odor absorption, FILTERS VOCs and the elimination of gases with low toxicity levels. 2 Technical features Dimensions PAINTING Type: Active carbon cylindrical cartridge. BOOTHS Carbon: Impregnated Active Carbon. Gasket: Neoprene. 3 Temperature: Should not exceed 45ºC Relative Humidity: Maximum 70% COMFORT Contact time: According to the application it can vary from PRODUCTS 0.1 to 0.2 seconds. 4 CALCULATION OF CONTACT TIME: Ct (sec.) = volume of active carbon (m3) / flow to be treated m3/h seconds. EPA/HEPA /ULPA Example Frame BTCGV2424 is fitted with 16 cartridges. 5 Cartridge CACGV145/450 contains 4.3 kg. Volume of carbon = 16 x 4.3 = 68.8 liters or 0.0688 m3/h HIGH Flow to be treated in the installation 1,200 m3h TEMPERA- CALCULATION TURE Ct(sec.) = 0.0688 / 1200 x 3600 = 0.2 seconds 6 The contact time is 0.2 seconds, the flows would be as follows: EQUIP- CACGV145/250 - 50 m3/h per cartridge MENTS CACGV145/450 - 75 m3/h per cartridge CACGV145/600 - 100 m3/h per cartridge 7 Advantages MOTORS AND - Reloadable cartridges with granulated active carbon. - Moludar system for adaptation to any installation. TURBINES References 8 Reference Model Diameters (mm) Carbon Thickness Carbon Minimum Nominal Initial UxP Stock ADSOR- (Kg) contact flow Pa ** TION AND CACGV145/250 CAC-GV time (s) DEODO- CACGV145/450 CAC-GV 145x85x250 26 mm. 2,9 (m3/h) 80 1F RIZATION CACGV145/600 CAC-GV 145x85x450 26 mm. 4,3 0,1 100 80 1F 145x85x600 26 mm. 5,7 0,1 150 80 1F 9 0,1 200 INTER- *UxP *Stock NATONAL Units per box F: Manufacture, S: Stock, SL: Limited Stock REGU- Venfilter [email protected] 267 LATION Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493
0 Adsortion and desodorization INFORMA- Multicarb TION Active Carbon Filters 1 Multi-dihedral carbon filter with half fold and active PRE- carbon. FILTERS 2 Technical features Dimensions PAINTING Type: Compact Polyhedral Rigid Bag Filter for deodorisation BOOTHS associated with a High Efficiency filter. Frame: Polypropylene. 3 Filtering Element: Combines active carbon pellet with synthetic fibers and microfibers with an efficiency of 95%, COMFORT according to EN 779, F7 and 85%, according EN779, M5. PRODUCTS Sealant: Polyurethane. Average Efficiency % (Em): 85% 4 EN 779 Class: F7. Recommended Fine Initial EPA/HEPA Pa: 250 Pa. /ULPA Temperature: Should not exceed 45ºC Retention capacity: 5 Organic substance toluene 952 g. Organic substance n-Butane 117 g. HIGH Inorganic substance SO2 350 g. TEMPERA- Inorganic substance HO2 5000 mg. TURE The retention capacity of the filter is determined for intake concentrations, according to standard E DIN 71460/part 2 6 Accumulation Capacity: (AC Fine/450 Pa) 650 g. EQUIP- MENTS Advantages 7 - Double action: A filtration F-7 class (EN 779: 2002) and adsorption of gases and odors in a single filtering stage. - Contaminants of low concentrations. - They don't rust and are incinerable 100%. - Interchangeable filters with pre-existing filter bags or compact filters. OZONO PURIFICATION EFFICIENCY: CAFP: 90% CAF: 70% References MOTORS Reference Model Dimensions Average EN 779 Filtering Carbon Nominal flow Initial Unit Weight UxP Stock AND BxHxP Efficiency % Class Surface (kg) (m3/h) Pa Volume (Kg) * * CAFP122412F7 CAF TURBINES CAFP202412F7 CAF 592x287x292 (Em) F7 (m2) 2,1 1700 120 (m3) 5,3 1 S CAFP242412F7 CAF 592x490x292 85% F7 4,3 3,6 2800 120 0,05 8,3 1 S 8 CAF 592x592x292 85% F7 7,5 4,4 3400 120 0,09 9,2 1 S CAFP122412 CAF 592x287x292 85% 9 2,1 1600 100 0,11 5,3 1 F ADSOR- CAFP202412 CAF 592x490x292 4,3 3,6 2400 100 0,05 8,3 1 F TION AND CAFP242412 592x592x292 7,5 4,4 3200 100 0,09 9,2 1 F DEODO- 9 0,11 RIZATION *UxP *Stock 9 Units per box F: Manufacture, S: Stock, SL: Limited Stock INTER- 268 Venfilter [email protected] NATONAL Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 REGU- LATION
Adsortion and desodorization Dimensions 0 Multicarb G INFORMA- TION Active Carbon Filters 1 Activated carbon filter multi-dihedral. PRE- Technical features FILTERS Type: Compact activated carbon filter 2 Frame: Polypropylene. Filtering Element: Panels activated carbon grains. PAINTING Sealant: Polyurethane. BOOTHS Temperature: Should not exceed 45ºC. 3 Advantages COMFORT - Odor Absorption. PRODUCTS 4 References EPA/HEPA /ULPA Reference Model Dimensions Carbon (Kg) Nominal Initial Pa Unit Volume Weight UxP* Stock* BxHxP flow (m3) (Kg) 5 8 1F CAFG122412GO CAFG 592x287x292 12 (m3/h) 70 0,05 13 1F HIGH CAFG202412GO CAFG 592x490x292 16 1700 70 0,09 16 1F TEMPERA- CAFG242412GO CAFG 592x592x292 2800 70 0,11 21 3400 TURE *UxP *Stock 6 Units per box F: Manufacture, S: Stock, SL: Limited Stock EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 269 INTER- www.venfilter.com NATONAL REGU- LATION
0 Adsortion and desodorization INFORMA- Policarb TION Active Carbon Filters 1 PRE- Poly-dihedral active carbon filter with a Galvanized flat FILTERS box with panels of granulated active carbon. 2 Technical features PAINTING Type: Compact activated carbon filter. Dimensions BOOTHS Frame: Galvanized Steel. Filtering Element: Active carbon dihedral panels. 3 Construction: The frame is made of galvanized steel. Gra- nulated activated carbon panels mounted on the galvanized COMFORT V-shaped frame, forming a highly robust multi-dihedral PRODUCTS structure. To prevent leaks between the galvanized frame and the carbon, a sealing is carried out using polyurethane 4 resin. Sealant: Polyurethane. EPA/HEPA Temperature: Should not exceed 45ºC. /ULPA Advantages 5 - Odor absorption. - Special application: radioactive ions. - Possibility of manufacturing with all the coals in our catalog. References HIGH Reference Model Dimensions Carbon Nominal flow Initial Unit Weight UxP* Stock* TEMPERA- BxHxP (Kg) (m3/h) Pa Volume (Kg) CAF112312GO CAF 1F TURE CAF232312GO CAF 290x595x292 10 1700 60 (m3) 18 1F CAFISO232312 CAF-ISO 595x595x292 20 3400 60 0.05 30 1F 6 CAFISO112312 CAF-ISO 595x595x292 20 3400 80 0.11 30 1F 290x595x292 10 1700 80 0,11 18 EQUIP- 0,05 MENTS 7 *UxP *Stock - other sizes: pleased consult. Units per box F: Manufacture, S: Stock, SL: Limited Stock MOTORS AND TURBINES 8 ADSOR- 270 Venfilter [email protected] TION AND Tel +34 937 862 607 www.venfilter.com DEODO- Fax +34 937 862 493 RIZATION 9 INTER- NATONAL REGU- LATION
Adsortion and desodorization 0 INFORMA- TION 1 PRE- FILTERS 2 PAINTING BOOTHS 3 COMFORT PRODUCTS 4 EPA/HEPA /ULPA 5 HIGH TEMPERA- TURE 6 EQUIP- MENTS 7 MOTORS AND TURBINES 8 Venfilter ADSOR- Tel +34 937 862 607 TION AND Fax +34 937 862 493 DEODO- RIZATION 9 [email protected] 271 INTER- www.venfilter.com NATONAL REGU- LATION
0 International normative INFORMA- International TION normative 1 Historical Standards PRE- YEAR REFERENCE TYPE OF TEST CLASSIFICATION FILTERS 1968 ASHRAE GRAVI-OPA 1980 GRAVI-OPA EU1 - EU4 / EU5 - EU9 2 1982 EUROVENT 4/5 GRAVI-OPA 1993 AFNOR NF X 44.012 GRAVI-OPA G1 - G4 / F5 - F9 PAINTING 2003 G1 - G4 / F5 - F9 + Media descargada BOOTHS CE EN 779 Gravimetric particles G1 - G4 / M5 - F9 Minimum efficiency 2012 CEN EN779:2002 3 2016 Gravimetric particles ePM1, ePM2.5, ePM10 2017 CEN EN779:2012 Gravimetric particles ePM1, ePM2.5, ePM10 COMFORT ISO 16890-1:2016 Gravimetric particles PRODUCTS ISO 16890-3:2017 4 Recommended minimum filter classes, by filter selection, depending on the type of supply air and the outside air quality according to EN16798-3: 2017 EPA/HEPA /ULPA Exterior air Air supply class quality 5 SuP1 SuP2 SuP3 SuP4 SuP5 HIGH (más elevado) (más bajo) TEMPERA- ODA 1 M5 + F7 F7 F7 F7 - TURE ODA 2 F7 + F7 M5 + F7 F7 F7 G3, M5 ODA 3 F7 + F9 F7 + F7 M6 + F7 F7 6 F7 EQUIP- The new standard EN 16798-3: 2017 refers to the standard EN 779, does not provide any recommendation for MENTS the selection of filters classified according to EN ISO 16890-1. 7 Historic Hepa Standards MOTORS YEAR REFERENCE TYPE OF TEST CLASIFICATION AND 1970 FED STD 209E DOP M1 a M7 TURBINES 1990 EN 1822/IEST DOP H10, H11, H12, H13, H14, U15, U16 2010 ISO 14644-1 DOP 8 2011 DOP Class 1 a Class 9 ISO 29463 E10, E11, E12, H13, H14, U15, U16 ADSOR- TION AND Venfilter DEODO- RIZATION Tel +34 937 862 607 [email protected] Fax +34 937 862 493 www.venfilter.com 9 272 INTER- NATONAL REGU- LATION
International normative 0 INFORMA- TION EN 13053 If bag filters are used then the filtration zone must be Normative at least 10 m² per 1 m² of the equipment transversal 1 section. The joints used must be of a closed cell type, they must not absorb humidity and they must not form a nutritive substrate for micro-organisms. Permanent PRE- Air treatment ventilation. Filters installed in air treat- fixing for the sealing must be guaranteed (for example, FILTERS operation from the dirty air side). Filtration sections ment units. from an inside height of 1,6 m must be set up with an The first filtration stage must be placed on the air inlet inspection window (with a minimum interior diameter 2 side, as near as possible to the opening for the outdoor of 150 mm) and light inside. air inlet, so as to keep the air treatment elements as In the fan section, for the purposes of setting the Initial PAINTING clean as possible. Additional pre-filters G1 to G4 are Pa value in the filter on designing the air flow, this BOOTHS authorized. The second filtration stage is placed on the must be the average of the initial and final drops for outlet side at the start of the air supply duct to keep it clean and dust filled filters respectively. clean. Note 1: The volumetric flow variation of air due 3 When just one filtration stage is used for the supply to dust accumulation must be indicated in the COMFORT system, the minimum that must be installed is a class technical specifications. If the specific tole- PRODUCTS F7 filter. rances for an application are not mentioned, <>10% is acceptable based on the average Initial In the case of using a two filtration stages, the air su- Pa. pply fan must be placed between the first and second The pressure drop of in a filter section that 4 filtration stages. With the aim of preventing the deve- lopment of microbes in the second stage air filters or is filled with solid particles must not ex- in a superior stage, the relative humidity in the filter ceed the values given in table 9. Lower Initial EPA/HEPA zone must be limited to 90%; temperatures below the drop can also be specified when appropriate. /ULPA dew point temperature must always be avoided. The air The filters installed in air treatment units used for hu- 5 filters must not be placed immediately after refrige- man occupation must be tested and classified in accor- ration batteries with dehumidification or after humidi- fiers (exception –steam humidifiers). dance with the EN 779 Standard. HIGH TEMPERA- TURE Maximum final Initial Pressure Drop for filters. Class of filter Final Initial 6 Pa G1 - G4 EQUIP- 150 Pa MENTS M5 - F7 200 Pa 7 F8 - F9 300Pa MOTORS AND TURBINES Note2: The final pressure drop indicated in the table for energy saving reasons are typical maxi- 8 mum values for working air treatment units and lower than those used in the EN 779 Standard for clas- sification purposes, and the performances obtained in the trials in accordance with the EN 779 Stan- ADSOR- dard are not necessarily fulfilled with these lower pressure drop. The following data must be shown in TION AND a clearly visible way (with a label) in the filter section: class of filter, type of filtering media, final Initial DEODO- Pressure Drop. On changing the filter, the user must verify and update this information. RIZATION Venfilter 9 Tel +34 937 862 607 Fax +34 937 862 493 [email protected] 273 INTER- www.venfilter.com NATONAL REGU- LATION
0 International normative INFORMA- TION Equivalence of Standards for Controlled 1 Rooms PRE- FILTERS Equivalence of international classification standards 2 No. of particles US Fed. Std 209E 1992 EN ISO 14644-1 France AFNOR NF European Union No. of particles >0,5 µm/m³ 1996 X 44.101 1981 Pharmaceutical > 0,1 µm/m³ PAINTING (aprox.) Industry Guide (approx.) BOOTHS ISO 1 1 ISO 2 BPF 1989 10 3 4 ISO 3 35 10 M1 1 ISO 4 4 000 A and B 100 COMFORT 35 M 1.5 10 ISO 5 350 PRODUCTS 100 M2 100 ISO 6 1 000 353 M 2.5 1 000 3 500 4 1 000 M3 10 000 10 000 3 530 M 3.5 100 000 35 000 EPA/HEPA 10 000 M4 100 000 /ULPA 35 300 M 4.5 350 000 100 000 M5 1 000 000 5 353 000 M 5.5 1 000 000 M6 ISO 7 400 000 C HIGH 3 530 000 M 6.5 TEMPERA- 10 000 000 M7 ISO 8 4 000 000 D 35 000 000 TURE ISO 9 6 BPF 1989 - Pharmaceutical Industry EQUIP- GuideMENTS 7 CLEAN ROOMS Classification of the different air qualities required to manufacture sterile products: MOTORS Maximum Nº of particles per m3 of air, with a dimension equal or superior to Max. Nº of microor- AND ganisms per m3 of air TURBINES (in activity) <1 0.5 µm 5 µm 0.5 µm 5 µm 10 3500 0 100 8A In non-activity (b) In activity 200 3500 0 [email protected] www.venfilter.com ADSOR- B 3500 0 350000 2000 TION AND C 350000 2000 3500000 20000 DEODO- D 3500000 20000 not defined (c) not defined (c) RIZATION 9 Venfilter Tel +34 937 862 607 INTER- 274 Fax +34 937 862 493 NATONAL REGU- LATION
International normative 0 Clean rooms and controlled annexed INFORMA- premises (US.FED.STD.209E) TION 1 PRE- FILTERS Class name Class limits 2 0,1 μm 0,2 μm 0,3 μm 0,5 μm 0,5 μm PAINTING BOOTHS S1 English mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ mᵌ ftᵌ M1 1 350 9,91 75,5 21,4 30,9 0,875 10 0,288 3 M 1,5 10 1240 335 265 7,5 106 3 35,3 1 247 7 M2 100 3500 99,1 757 21,4 309 8,75 100 2,83 618 17,5 COMFORT M 2,5 12499 360 2650 75 1060 30 353 10 2470 70 PRODUCTS M3 35000 991 7570 214 3090 87,5 1000 28,3 6180 175 M 3,5 26500 750 10600 300 3530 100 24700 700 4 M4 75700 2140 30900 875 10000 283 61800 1750 M 4,5 35300 1000 EPA/HEPA M5 1000 100000 2830 /ULPA M 5,5 353000 100000 M6 10000 1000000 28300 5 M 6,5 3530000 100000 M7 100000 10000000 283000 HIGH TEMPERA- EN ISO 14644 Standard TURE Classes by type of air particle cleaning for clean rooms and protected zones. 6 Classification Maximum admissible concentration (particles per m3 of air) for particle dimensions equal or superior to: Number EQUIP- 0,1 0,2 0,3 0,5 1 5 MENTS ISO CD 14644.1 10 2 (1996) 100 24 10 4 8 29 7 1000 237 102 35 83 293 ISO 1 10000 2370 1020 352 832 2930 MOTORS ISO 2 100000 23700 10200 3520 8320 29300 AND ISO 3 1000000 237000 102000 35200 83200 293000 ISO 4 352000 832000 TURBINES ISO 5 3520000 8320000 ISO 6 35200000 8 ISO 7 ISO 8 ADSOR- ISO 9 TION AND DEODO- Venfilter [email protected] 275 RIZATION Tel +34 937 862 607 www.venfilter.com Fax +34 937 862 493 9 INTER- NATONAL REGU- LATION
Edition: June 2022
Search
Read the Text Version
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 76
- 77
- 78
- 79
- 80
- 81
- 82
- 83
- 84
- 85
- 86
- 87
- 88
- 89
- 90
- 91
- 92
- 93
- 94
- 95
- 96
- 97
- 98
- 99
- 100
- 101
- 102
- 103
- 104
- 105
- 106
- 107
- 108
- 109
- 110
- 111
- 112
- 113
- 114
- 115
- 116
- 117
- 118
- 119
- 120
- 121
- 122
- 123
- 124
- 125
- 126
- 127
- 128
- 129
- 130
- 131
- 132
- 133
- 134
- 135
- 136
- 137
- 138
- 139
- 140
- 141
- 142
- 143
- 144
- 145
- 146
- 147
- 148
- 149
- 150
- 151
- 152
- 153
- 154
- 155
- 156
- 157
- 158
- 159
- 160
- 161
- 162
- 163
- 164
- 165
- 166
- 167
- 168
- 169
- 170
- 171
- 172
- 173
- 174
- 175
- 176
- 177
- 178
- 179
- 180
- 181
- 182
- 183
- 184
- 185
- 186
- 187
- 188
- 189
- 190
- 191
- 192
- 193
- 194
- 195
- 196
- 197
- 198
- 199
- 200
- 201
- 202
- 203
- 204
- 205
- 206
- 207
- 208
- 209
- 210
- 211
- 212
- 213
- 214
- 215
- 216
- 217
- 218
- 219
- 220
- 221
- 222
- 223
- 224
- 225
- 226
- 227
- 228
- 229
- 230
- 231
- 232
- 233
- 234
- 235
- 236
- 237
- 238
- 239
- 240
- 241
- 242
- 243
- 244
- 245
- 246
- 247
- 248
- 249
- 250
- 251
- 252
- 253
- 254
- 255
- 256
- 257
- 258
- 259
- 260
- 261
- 262
- 263
- 264
- 265
- 266
- 267
- 268
- 269
- 270
- 271
- 272
- 273
- 274
- 275
- 276
- 277
- 278