Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore Product Catalogue 2016_6 - v2

Product Catalogue 2016_6 - v2

Published by Satron Instruments Inc, 2016-07-21 00:56:01

Description: Product Catalogue 2016_6 - v2

Search

Read the Text Version

Index 101Mounting couplings for Satron VG transmitter G150 10.2.2015Thread and clamp couplingsStandard coupling G1 Standard coupling G1 Hygienic coupling G1 with cleaningOrder codes: Order codes:- AISI316L M546197 Order codes: M1050020 - AISI316L M548101- Duplex M5461978 - AISI316L M10500208 - Duplex M5481018- Hastelloy C276 M5461973 - Duplex M10500203 - Hastelloy C276 M548102- Titanium M5461976 - Hastelloy C276 M10500206 - Titanium M548103 - TitaniumCoupling G1 / G½A Coupling G1 / ½ -NPT Coupling G1 / G¾AOrder code: M546190 Order code: M551566 Order code: T1050218- AISI316L - AISI316L - AISI316LCoupling G1 / G1A Coupling G1 / G1¼A Coupling G1 / G1½AOrder codes: Order code: Order code: - AISI316L - AISI316L- AISI316L M1050002 M1050014 T1050214- Hastelloy C276 M10500023 Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 102Mounting couplings for Satron VG transmitter G150 10.2.2015Coupling G1 / G2A Coupling G1 / 2-NPT Coupling G1 / M44 x 1,25 (PMC)Order code: Order code:- AISI316L M1050036 - AISI316L M1050028 Order codes: - AISI316L M1050004 - Hastelloy C276 M10500043Coupling G1 / Hygienic Coupling G1 / Hygienic Coupling G1 / Hygieniccoupling ISO2852 standard: coupling SMS standard: coupling DIN11851/11887 standards:Order codes (AISI316L):- Tri-Clamp 25/38 M1050206 Order codes (AISI316L):- Tri-Clamp 40/51 M1050222- Tri-Clamp 63,5 M1050224 - SMS 38 M1050265 Order codes (AISI316L):- Tri-Clamp 70 M1050225- Tri-Clamp 76,1 M1050226 - SMS 51 M1050267 - DN40 M1050312- Tri-Clamp 88,9 M1050227- Tri-Clamp 101,6 M1050228 - DN50 M1050313- Tri-Clamp 114,3 M1050229- Tri-Clamp 139,7 M1050230 - DN65 M1050314Coupling G1 / PMC 1,5\" Extended coupling G1 Extended coupling G1 with cleaningOrder codes: Order codes:- AISI316L M1050010 Order code: - AISI316L M1050292 - AISI316L- Hastelloy C276 M10500103 M1050293 - Hastelloy C276 M10502923

Index 103Mounting couplings for Satron VG transmitter G150 10.2.2015Coupling G1 / G½A + drain Coupling G1 for pipes Coupling G1 for pipesvalve DN15 - DN25 and clean DN15 - DN40 liquidsOrder code: Order codes (AISI316L):- AISI316L M860280 Order codes (AISI316L): - DN15 M105001615 - DN15 M1050295 - DN20 M105001620 - DN20 M1050296 - DN25 M105001625 - DN25 M1050297 - DN32 M105001632 - DN40 M105001640Coupling G1 / G½A (male) Coupling G1 / G½ (female) Coupling G1 / Ø52,5 L=38with mounting bracket with mounting bracket (SMS nut fixing, size 38, thread 60 x 1/6)Order code: Order code:- AISI316L M546195 - AISI316L M550393 Order code: - AISI316LCoupling G1 / ½ - NPT Coupling G1 / ½ - NPT M1050575(male) with mounting bracket (female) with mounting bracketOrder code:- AISI316L M1050017 Order code: - AISI316L M550393N

Index 104Mounting couplings for Satron VG transmitter G150 10.2.2015 ØD 19,5 Ø45Coupling G1 / SMS-SI G1Coupling G1 / Sandvik-clamp Thread sleeve G1- with extension - Extension length 54,5 mm (eg. for coupling M1050002)Order codes (AISI316L): Order codes: Order codes: - AISI316L- SMS-SI38 M1050012 - Duplex M1050037 - AISI316L M1050220 - Hastelloy C276 M10500378- SMS-SI51 M1050126 M10500373 - Hastelloy C276 M10502203Flange couplings COUPLING TYPE FLANGE TYPE G1 std. G1 std. HC G1 hyg. G1 hyg. HC G1 Exi G1 Exi HC DN25 PN40 ORDER CODE ORDER CODE ORDER CODE ORDER CODE ORDER CODE ORDER CODE DN40 PN40 DN50 PN40 M548832 M5488323 M548833 M5488333 M548834 M5488343 DN80 PN40 M551267 M5512673 M551268 M5512683 M552361 M5523613 DN100 PN40 M860282 M8602823 M548830 M5488303 M548831 M5488313 ANSI1\"150LBS M860281 M8602813 M548828 M5488283 M548829 M5488283 ANSI1\"300LBS M552364 M5523643 M55236403 ANSI2\"150LBS M552365 M5523653 M5523640 M5523641 M55236413 ANSI2\"300LBS M548861 M5488613 M5523650 M55236503 M5523651 M55236513 ANSI3\"150LBS M552367 M5523673 M548862 M5488623 M548863 M5488633 ANSI3\"300LBS M548864 M5488643 M5523670 M55236703 M55236713 ANSI4\"150LBS M551564 M5515643 M548865 M5488653 M5523671 M5488663 ANSI4\"300LBS M5488673 M5515640 M55156403 M548866 M548867 M5523713 M548868 M5515641 M55156413 M552371 M5523723 M5523710 M5488683 M548869 M5488693 M552372 M5523720 M55237103 M55237203 M5523711 M55237113 M5523721 M55237213 FOR GASKET CHANNEL : (DIN 2512N) M5488253 DN25 PN40 M548825 M5488223 M548826 M5488263 M548827 M5488273 M5488193 M548823 M5488233 M548824 M5488243 DN50 PN40 M548822 M548820 M5488203 M548821 M5488213 DN80 PN40 M548819Multidimensional flangecoupling COUPLING TYPE G1 std. G1 std. HC G1 hyg. G1 hyg. HC G1 Exi G1 Exi HC D ORDER CODE ORDER CODE ORDER CODE ORDER CODE ORDER CODE ORDER CODE 92 M1050030 M10500303 M1050031 M10500313 M1050032 M10500323 127 M1050033 M10500333 M1050034 M10500343 M1050035 M10500353

Index 105Mounting couplings for Satron VG transmitter G150 10.2.2015 ØD Pipe Dim. Dim. Dim. Dim. Order code Material size Ødu AB ØD DN15 80 96 DN20 80 83 101 20 +0.5 M1050303xx Should be mentioned in DN25 86 108 +0.2 M1050304xx the order 80 M1050305xx +0.2 Ø20.5 DN32 91 117 25 +0.5 M1050306xx Should be mentioned in +0.1 DN40 80 95 127 +0.2 M1050307xx the order Ødu DN50 103 141 M1050308xxG1 Ø25 80 32 +0.5 Should be mentioned in 100 +0.2 the order 100 40 +0.5 Should be mentioned in +0.2 the order 50 +0.5 Should be mentioned in +0.2 the order 63 +0.5 Should be mentioned in +0.2 the order A Plastic coupling G1 for plastic B pipes DN15 - DN50Coupling G1 / Varivent TN Hygienic Coupling G1 / Ø38 Seal plug assembly for Satron coupling G1Order code (AISI316L): Order code: M1050577 - AISI316L M1050577HC By seal plug the coupling can be- DN25 M1050090 - Hastelloy C closed tightly.- DN50/40 M1050091 Order code: - AISI316L- DN80/65 M1050092 - EHEDG M550405 M1050389Welding assistant for Satron Special adapter for Satron Seal for Satron couplings G1.coupling G1. couplings G1. Enables to seal the leaking metalIt is always recommendable to use By using this adapter it is possible to metal taper.the welding assistant while welding to install the sensor head ca. 3mmthe coupling to prevent any deep into the coupling. Order code: T546022distortions due to heat. - PTFE Order code:Order code: - EN 1.4462 (Duplex) M1050294- Brass M1050420

Index 106Mounting couplings for Satron VT Transmitters G160 01.01.2015 Process couplings with DIN 3852-X thread Order code: AISI316L Order code Thread A Du 0 Length L d4 a1 - 0.5 18,5 Ø27 2.5 23.5 Ø40 2.5 M1050369 G½ Ø30 32.5 Ø56 2.5d4 26.5 Ø56 2.5 G¼ M1050390 G1 Ø45 33 Ø69 3.0 M1050391 G1½ A Ø60 A M1050393 G1½ Ø60 Ø20M1050392 G2 Ø75 Du Du a1 G3/8L Ø28 G½Process couplings with NPT thread Ø28 Order code: AISI316L Order code Thread A Du Length L M1050368 ½-14 NPT Ø28 14 M1050500 ¾-14 NPT Ø35 16 M1050501 1 - 11½ NPT Ø44.5 20.5 M1050502 1¼ - 11½ NPT Ø57.5 20.5 M1050503 1½ - 11½ NPT Ø63.5 20.5 L M1050504 2 - 11½ NPT Ø76 20.5 30 30 20Process coupling DIN 16288 - G¼ Process coupling G½ Process coupling DIN 16288 - G½Order code: M1050366 Order code: M1050316 Order code: M1050367- AISI316L - AISI316L - AISI316LØ27 G½ Ø18,3 Ø30 Ø26,5 Ø33,5 2 23,5 25,5Process coupling DIN 3852 - X - Process coupling PMC 1\"G½, for transmitter with two o-ringOrder code: Order code: - AISI316L- AISI316L M1050515 M1050300 Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 107Mounting couplings for Satron VT Transmitters G160 01.01.2015 ØD out T-coupling DIN 3852-X-G½ Ø27 +0.4 G½B A Order codes: AISI316L 2.5 Pipe Dim. Dim. Dim. Dim. Dim. Dim. Order code Ød size øD out A B C Ød E C DN15 40 27.5 43.5 36 22 0 29.5 M1050395 DN20 40 30.5 26 M1050396 DN25 50 33.5 49 42 27.5 +0.3 29.5 M1050397 55.5 48 0 34 +0.5 +0.2 Other size, please contact Satron Instruments Inc. E Coupling flange DIN 3852-X-G½ - for the transmitter with two o-rings Tilauskoodit: AISI316L G½ ORDER CODE TYPE OF FLANGE M1050517-DN25 DN 25 PN 40 M1050517-DN40 DN 40 PN 40 M1050517-DN50 DN 50 PN 40 M1050517-DN80 DN 80 PN 40 M1050517-DN100 DN 100 PN 16 M1050517-1-150 ANSI 1\" 150 LBS M1050517-1-300 ANSI 1\" 300 LBS M1050517-2-150 ANSI 2\" 150 LBS M1050517-2-300 ANSI 2\" 300 LBS M1050517-3-150 ANSI 3\" 150 LBS M1050517-3-300 ANSI 3\" 300 LBS M1050517-4-150 ANSI 4\" 150 LBS M1050517-4-300 ANSI 4\" 300 LBS L Special flanges, please contact Satron Instruments Inc. A Welding assistant: Order codes A L Order code Thread A Dim. L Position, form and size M1050516 G½A 25 6-k, AV22 M1050375 G¾A 15 6-k, AV27 M1050371 G1A 20 6-k, AV36 M1050372 G1 ¼A 35 4-k, AV22 M1050373 G1 ½A 35 4-k, AV22 M1050374 G2A 35 4-k, AV22

Index 108

Index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

Index 110 ! , \" !# ! $ !% & ' ' \" #$ , !! \"# $$ \" %% & '(!! ) \"$ $% ! ! % $ *$! \" %% & '( * \"$% \" %% & '( *\" $ %& ' \" + $% \"* \" \" + $% ,!! * \" && ! $ $% + (' - \" & . & / !! + ' \" +\" ! & / !& ' (\" \"\" $ $ &$ / & !' \" '!+ ( $ &$ & $ $ !\" $ ' $/ \" 0$ $ !! $ \" 1 / $ !\" ' /! \" $ $/ &$ & $ ( !! $ ' & + \" !! $ )* % ' ' $+ $& * 23 3 - . 4565 7 ) & (- 8 9 23 8 -$ '&

Index 111 %& # $ $$ ' &( & & ! \"#$ % ( &' & & &' & & &' & & ## \"#) * + ( + + & \"#\" , (( & & ,+ -( -% & -' * - , . # )- . # \" /01) ## . # 2 /01) 3+ 4 +$ + +( 5 67 +) + +( 5 67 +\" !\" + +( 6 67 +2 4

Index BP415 112 2012-08-15 SATRON HPS Hydraulic Pressure SealThe Hydraulic Pressure Seal SATRON HPS isused in pressure measurement applications wherethe process medium is aggressive and it isnecessary to protect the wetted parts of measuringtransmitters. Processes' hygienic requirementsmay also necessitate the use of the pressure seal.In addition, the pressure seal has to be used whenthe process temperature exceeds the transmitter'sspecifications.Technical specificationsProcess connections Fill fluids Silicone oil DC705• DN25,DN50, DN80, DN100 Silicone oil DC200 • for high-temperature and vacuum • for process and food industry measurement applications (EN 1092-1,flange type 05, facing applications Gaskets (Sanitary Seal) type B), (DIN 2501, form D) Neobee M20 • EPDM, FPM (Viton®) and PTFE• ANSI2\" and 3\" (ANSI B16-5) • for food industry applications• JIS 50, 80, 100 (JIS B 2220) Inert oil (e.g. Fomblin Y04 or• Sandvik Clamp connector DN65 Halocarbon)• TRI-Clamp 1½\", 2\" and 2,5\" (38/51/ • for oxygen and chlorine applications 63,5 mm, ISO2852)• SMS38 and SMS51• DIN11851 DN25 ... DN50 Other options available on separate order.Process pressures Fill fluid properties• PN10/16, PN40, PN64 and PN100• 150 and 300 lbs Fill fluid Temperature Density Thermal expansion Viscosity (25°C)• 10K and 50K• Sandvik Clamp: PN64 range/°C g/cm3 coefficient/ 1/°C cSt(mm2/s)• TRI-Clamp: PN40• SMS and DIN11851 PN25 PN40 DC200 -40...200 0.934 0.00108 9.5 Silicone oilMeasurement ranges DC705 20...380 1.090 0.00080 175Above 25 mbar span, depending on the Silicone oil -45...175 1.850 0.000864 6.5measuring diaphragm's size and theprocess pressure. Inert oilMaterials NeobeeM20 -17...200 0.917 0.001008 9.8HPS body: EN 1.4401 (AISI 316)Process coupling: EN 1.4404 (AISI Fill fluid steam pressure curves (specified by manufacturers)316L)Capillary tube Temperature/°C 250• Capillary: EN 1.4401 (AISI 316) 200• Casing: EN 1.4401 (AISI 316) 150 DC200/10Length selectable between 2 and 20 m. 100 HalogarbonRecommendation: As short as possible. Neobee M20The capillary's minimum permissible 50bending radius is 50 mm. 0We recommend capillaries of equallength for differential pressure 0measurements in varying temperature 10conditions. 20 30Diaphragm materials 40EN 1.4435 (AISI 316L), CoNi-alloy, 50Duplex (EN 1.4462), Hastelloy C22 60(EN 2.4602) / C-276 (EN 2.4819), 70Inconel 600 (EN 2.4816), Monel 400 80(EN 2.4360), Nickel (EN 2.4066), 90Tantalum, Titan Ti-II (3.7035) and 100Zirkonium 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 350 450 550 650 750 850 950 Pressure/mbar abs. Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 113SATRON HPS Hydraulic Pressure Seal BP415 2012-08-15HPS types: construction SATRON HPS D SATRON HPS TRI-C - Mounted between - Mounted on Tri-Clamp two flanges (ISO2852) - Sanitary seals SATRON HPS F SATRON HPS SMS - Flange-mounted - Sanitary seals - Female Rd-thread pressure seal SATRON HPS E SATRON HPS DIN11851 - Flange-mounted - Sanitary seals - Female Rd-thread with extension SATRON HPS S SATRON HPS SMS-SI - Mounted on - Sanitary seals - Female Rd-thread Sandvik Clamp - Sanitary seals 2

Index 114 BP415SATRON HPS Hydraulic Pressure Seal 2012-08-15 Mounting dimensions d2 ød 4 ød b E b k D Type F Type E 120 Ød1 22 Type D FLANGE FLANGE FLANGE DIMENSIONS HOLES EXTENS. SIZE CODE b D Ød4 Ød1 Kpl d2 k Ød -0.2 ISO DN25 PN10/16 D1A 16 115 68 70 ISO DN25 PN40 4 14 85 - ISO DN25 PN64 ISO DN25 PN100 D1B 18 115 68 70 4 14 85 - ISO DN50 PN10/16 ISO DN50 PN40 D1C 24 140 68 70 4 18 100 - ISO DN50 PN64 ISO DN50 PN100 D1D 24 140 68 70 4 18 100 - ISO DN80 PN10/16 ISO DN80 PN40 D2A 18 165 102 105 4 18 125 51 ISO DN80 PN64 ISO DN80 PN100 D2B 20 165 102 105 4 18 125 51 ISO DN100 PN10/16 ISO DN100 PN40 D2C 26 180 102 105 4 22 135 51 ANSI 2\" 150 lbs D2D 28 195 102 105 4 26 145 51 ANSI 2\" 300 lbs ANSI 3\" 150 lbs D3A 20 200 138 140 8 18 160 73 ANSI 3\" 300 lbs ANSI 4\" 150 lbs D3B 24 200 138 140 8 18 160 73 ANSI 4\" 300 lbs JIS 10K-50 D3C 28 215 138 140 8 22 170 73 JIS 40K-50 JIS 10K-80 D3D 32 230 138 140 8 26 180 73 JIS 40K-80 JIS 10K-100 D4A 20 220 158 166 8 18 180 73 JIS 40K-100 D4B 24 235 162 166 8 22 190 73 4 20 120.6 51 A2A 23 152 92 99 8 20 127 51 A2B 25 165 92 105 4 20 152.4 73 A3A 26 191 127 130 A3B 31 210 127 8 23 168.3 73 143 8 20 190.5 73 A4A 26 229 157 168 A4B 34 254 157 8 23 200 73 J2A 16 155 96 175 4 19 120 51 96 8 19 130 51 +0.4 J2B 26 165 105 105 E - 0.4 J3A 18 185 126 126 8 19 150 73 CODE J3B 32 210 140 140 8 23 170 73 2 51 J4A 18 210 151 151 8 19 175 73 4 102 J4B 36 250 165 165 8 25 205 73 6 152 3

Index 115 BP415 SATRON HPS Hydraulic Pressure Seal 2012-08-15Selection table : Flanged Seal HPSProcess connection typeD PancakeF FlangedE Flanged with extensionProcess connection standadD DIN (Deutsches Institut für Normung)A ANSI/ASME B16.5 (American National Standards InstituteJ JIS (Japanese Industrial Standards)Process connection size ANSI JIS DIN - - 2\" 501 25 3\" 802 50 4\" 1003 804 100Pressure class of process connection (maximum working pressure)DIN ANSI JISA PN10/16 150lbs 10KB PN40 300lbs 40KC PN64 - -D PN100 - -Extension length (only codes D and F)0 No extension (only code E)2 Extension 51 mm (only code E)4 Extension 102 mm (only code E)6 Extension 152 mmFlange material / in type E also extension material2 EN 1.4404 (AISI316L)3 Hastelloy C-276 (EN 2.4819)8 Duplex (EN 1.4462)Diaphragm material 7 CoNi-alloy1 Nickel (EN 2.4066) (***) 8 Duplex (EN 1.4462)2 EN 1.4435 (AISI316L) H Hastelloy C22 (EN 2.4602)3 Hastelloy C-276 (EN 2.4819) M Monel 400 (EN 2.4360)4 Inconel 600 (EN 2.4816) Z Zirkonium (***)5 Tantalum6 Titan TI-II (EN 3.7035) (***)Diaphragm thickness P PTFE sinteredE 0.05 mm (*)F 0.10 mm (**)Diaphragm coating0 No coating9 Gold / RhodiumY DiamondFill fluidS Silicone oil DC200A Neobee M20, oil for food industryG Inert oilD Silicone oli DC705 (*) = Not Inconel, Monel, Nickel or Zirkonium (**) = Not Tantalum (***) = Not connection type E (with extension) 4

Index 116

Index 117SATRON HPS Hydraulic Pressure Seal BP415 2012-08-15Mounting dimensions type SMS Mounting dimensions type DIN11851 AA g ØD Ød6 Size Dimensions Thread Size Dimensions Thread 38 ØD A Rd 60 x 1/6 DN25 PN25 Ød6 g A Rd 52 x 1/6 51 54 21 Rd 70 x 1/6 DN32 PN25 Rd 58 x 1/6 64 23 DN40 PN25 44 10 49 Rd 65 x 1/6 DN50 PN25 Rd 78 x 1/6 50 10 49 56 10 49 68,5 11 50Mounting dimensions type SMS-SI SMS-SI couplings : L2 L1 AE ØD Ød ØD for pipe for vessel Size Dimensions Thread Size Dimensions 38 SI38 ØD A E Rd 60 x 1/6 51 L1 Ød L2 ØD Thread SI51 54 21 24 Rd 70 x 1/6 27 38,5 24 60 Rd 60 x 1/6 64 23 27 30 51 25 70 Rd 70 x 1/6 6

Index 118 BP415 SATRON HPS Hydraulic Pressure Seal 2012-08-15Hydraulic Pressure Seal ConnectionsCapillary connection120 120 Seal on Low or High pressure side of Same seal on both High and Low pressure sides Differential PressureTransmitter, code H or K of Differential Pressure Transmitter, code LSelection tableCapillary connection type 120H Seal on High pressure Seal on High pressure side of pressure side of Differential Transmitter transmitter, process connection G½A, code MK Seal on Low pressure 7 side of Differential TransmitterL Same seal on both High and Low pressure side of Differential TransmitterM Seal on High pressure side of Pressure Transmitter, process connection G½ACapillary length (m)2...20Mounting bracket for transmitter0 No mounting bracket1 Angle mounting bracket2 Mounting plateDocumentationIE EnglishIF FinnishMaterial certificate0 No material certificateMC1 SFS-EN 10204-2.1 (DIN50049-2.1)MC2 SFS-EN 10204-2.2 (DIN50049-2.2)MC3 SFS-EN 10204-3.1B (DIN50049-3.1B)

Index 119 BP415 SATRON HPS Hydraulic Pressure Seal 2012-08-15Hydraulic Pressure Seal ConnectionsDirect mounted connection Seal on High pressure side of Seal on High pressure side of Differential Pressure Transmitter, Differential Pressure Transmitter, angle model, code P straight model, code RSelection table Seal on High pressure side of Pressure Transmitter, processDirect mounted connection type connection G½A, straight model, code SP Seal on High pressure side of 8 Differential Transmitter, angle modelR Seal on High pressure side of Differential Transmitter, straight modelS Seal on High pressure side of Pressure Transmitter, process connection G½A, straight modelDocumentationIE EnglishIF FinnishMaterial certificate0 No material certificateMC1 SFS-EN 10204-2.1 (DIN50049-2.1)MC2 SFS-EN 10204-2.2 (DIN50049-2.2)MC3 SFS-EN 10204-3.1B (DIN50049-3.1B)

Index 120

Index 121 BP415 SATRON HPS Hydraulic Pressure Seal 2012-08-15Type SMS-SI Type DIN11851 O-ring Pressure seal Gasket Pressure seal CouplingTyyppi SMS CouplingCoupling Gasket Pressure sealSpecification example: SATRON HPS KA23E0S10-M52IE0- Process connection type, sanitary DN25 DIN11851- Material of body: EN 1.4404 (AISI316L)- Diaphragm material: Hastelloy C-276 (EN 2.4819)- Diaphragm thickness: 0.05mm- No diaphragm coating- Fill fluid: silicone oil- Material of process gasket: EPDM- No mounting parts- Capillary type connection: - Seal on high pressure side of Pressure Transmitter - Capillary length 5m - Mounting bracket for transmitter, type mounting plate - Documentation: English - No material certificationRecommended minimum process pressurefor vacuum applications Minimum pressure for different fill fluids (kPa, abs.)Tproc. DC200 Inert oil°C 100 cSt20 5 8 Hastelloy is the registered trademark of Haynes International.40 8 10 Teflon is the registered trademark of E.I. du Pont de Nemours & Co.80 10 28 Viton is the registered trademark of DuPont Dow Elastomers.120 15 53160 25 90 We reserve the right for technical modifications without prior notice.200 40 - 10

Index 122 115061002-EN SATRON HPS BA / BB Hydraulic Pressure Seal 30.06.2012 The Hydraulic Pressure Seal SATRON HPS is used in pressure measure- ment applications where the process medium is aggressive and it is neces- sary to protect the wetted parts of measuring transmitters. Processes' hygienic requirements may also ne- cessitate the use of the pressure seal. In addition, the pressure seal has to be used when the process tem- perature exceeds the transmitter's specifications. Technical specifications Process connections • Thread M45 x 2 Process pressures • PN200 Measurement ranges Fill fluid properties Above 25 mbar span, depending on the measuring diaphragm's size and the Fill fluid Temperature Density Thermal expansion Viscosity (25°C) process pressure. range/°C g/cm3 coefficient/ 1/°C cSt(mm2/s) Materials HPS body: EN 1.4404 (AISI 316L), EN DC200 -40...200 0.934 0.00108 9.5 1.4462 (Duplex) Silicone oil Capillary tube DC705 20...380 1.090 0.00080 175 • Capillary: AISI 316 Silicone oil • Casing: AISI 316 Length selectable between 2 and 20 m. Inert oil -45...175 1.850 0.000864 6.5 Recommendation: As short as possible. The capillary's minimum permissible Neobee M20 -17...200 0.917 0.001008 9.8 bending radius is 50 mm. We recommend capillaries of equal length for differential pressure measurements in varying temperature conditions. Diaphragm materials Recommended minimum process pressure AISI 316L (EN 1.4435), CoNi-alloy, Duplex for vacuum applications (EN 1.4462), Hastelloy® C22 / C-276 (EN 2.4819), Inconel 600 (EN 2.4816), Tantalum Minimum pressure for Fill fluids different fill fluids (kPa, abs.) Silicone oil DC200 • for process and food industry applica- T DC200 Inert oil tions proc. Neobee M20 • for food industry applications °C 100 cSt Inert oil (e.g. Fomblin Y04 or Halocarbon) • for oxygen and chlorine applications 20 5 8 Silicone oil DC705 40 8 10 • for high-temperature and vacuum me- 80 10 28 asurement applications 120 15 53 160 25 90 Gaskets 200 40 - • FPM (Viton®) Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 123 Hydraulic Pressure SealSATRON HPS BA / BB 115061002-EN 30.06.2012Selection table: M45 x 2 Seal HPSProcess connection typeBA M45 x 2 with o-ringBB M45 x 2 with o-ring + metal/metal taperBody material, wetted parts2 AISI316L (EN 1.4404) 8 Duplex (EN 1.4462), std.3 Hastelloy C-276 (EN 2.4819) Hastelloy C276 (EN 2.4819) TantaaliDiaphragm material 32 AISI316L (EN 1.4435) 54 Inconel 600 (EN 2.4816)8 Duplex (EN 1.4462)Diaphragm thickness F 0.10 mmE 0.05 mmDiaphragm coating P PTFE sintered0 No coating Y Diamond9 Gold / Rhodium GFill fluid D Inert oilS Silicone oil DC200 Silicone oil DC705A Neobee M20, oil for food industryMounting parts0 No mounting parts1 Coupling2 Pasve BA mounting valve, specify separately in the order 2

Index 124 115061002-EN Hydraulic Pressure Seal SATRON HPS BA / BB 30.06.2012 Mounting dimensions, type BA Mounting dimensions, type BB 3

Index 125 115061002-EN Hydraulic Pressure Seal SATRON HPS BA / BB 30.06.2012Hydraulic Pressure Seal ConnectionsCapillary connection Seal on Low or High pressure side of Diffe- Same seal on both High and Low pressure sides rential PressureTransmitter, code H or K of Differential Pressure Transmitter, code LSelection tableCapillary connection type Seal on High pressure side of pressure trans-H Seal on High pressure mitter, process connection G½A, code M side of Differential Transmitter 4K Seal on Low pressure side of Differential TransmitterL Same seal on both High and Low pressure side of Differential TransmitterM Seal on High pressure side of Pressure Transmitter, process connection G½ACapillary length (m)2...20Mounting bracket for transmitter0 No mounting bracket1 Angle mounting bracket2 Mounting plateDocumentationIE EnglishIF FinnishMaterial certificate0 No material certificateMC1 SFS-EN 10204-2.1 (DIN50049-2.1)MC2 SFS-EN 10204-2.2 (DIN50049-2.2)MC3 SFS-EN 10204-3.1B (DIN50049-3.1B)

Index 126 115061002-EN Hydraulic Pressure Seal SATRON HPS BA / BB 30.06.2012Hydraulic Pressure Seal ConnectionsDirect mounted connection Seal on High pressure side of Diffe- Seal on High pressure side of Diffe- rential Pressure Transmitter, angle rential Pressure Transmitter, straight model, code P model, code RSelection table Seal on High pressure side of Pressure Transmitter, processDirect mounted connection type connection G½A, straight model, code SP Seal on High pressure side of 5 Differential Transmitter, angle modelR Seal on High pressure side of Differential Transmitter, straight modelS Seal on High pressure side of Pressure Transmitter, process connection G½A, straight modelDocumentationIE EnglishIF FinnishMaterial certificate0 No material certificateMC1 SFS-EN 10204-2.1 (DIN50049-2.1)MC2 SFS-EN 10204-2.2 (DIN50049-2.2)MC3 SFS-EN 10204-3.1B (DIN50049-3.1B)

Index HPS BA / BB 127 115061002-EN Hydraulic Pressure Seal SATRON 30.06.2012Specification example: SATRON HPS BB88E0S0-M52IE0- Process connection type: Thread M45 x 2 with o-ring + metal/metal taper- Body material: EN 1.4462, Duplex- Diaphragm material: EN 1.4462, Duplex- Diaphragm thickness: 0.05mm- No diaphragm coating- Fill fluid: silicone oil- No mounting parts- Hydraulic Pressure Seal Connections: Capillary type connection - Seal on High pressure side of pressure transmitter, process connection G½A, - Capillary length 5m - Mounting bracket for transmitter, type mounting plate - Documentation: English - No material certificationWelding the coupling 52,5 Welding plug, brass M1050473 Ø60Welding sequence Hastelloy is the registered trademark of Haynes International. Teflon is the registered trademark of E.I. du Pont de Nemours & Co. Viton is the registered trademark of DuPont Dow Elastomers. We reserve the right for technical modifications without prior notice.

Index 128

Index 129Actuators and accessories 5/04 ACTUATORS April 30, 2010 - PISTOR 75 pneumatic power cylinder ................................................................................ Spec. EZ510 Satron Instruments Inc., P.O.Box 22, FIN-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 130 EZ510 pneumatic power cylinder PISTOR 75 Febr. 15, 1989The pneumatic PISTOR power cylindercan be used as an actuator in manualand automatic control of control valvesand louvers.Technical specification Type PISTOR 75/150 PISTOR 75/300Piston diameter: 75 mm 75 mmStroke S: 150 mm 300 mmEffective cross-sectionalarea of piston: 41 cm2 41 cm2Output force- for 3 bar supply pressure: 1200 N 1200 N- for 6 bar supply pressure: 2400 N 2400 NOutput work (moment of force)- for 3 bar supply pressure: 180 Nm 360 Nm- for 6 bar supply pressure: 360 Nm 720 NmTypical time for full stroke:Weight: 12 s 20 s 2.8 kg 3.4 kgSupply pressure: 3 to 6 bar. Sensitivity: 0.3 %.Control pressure range Load effect- with standard adjustment: - for a load change from 0 to 80 % of the max. force obtainable for the 0.2 to 1.0 bar supply pressure in use, the effect is- on separate order: 4 % of max.stroke per 1000 N. 0.4 to 0.9 bar spans. Materials We reserve the right to make technical - body: light alloy with epoxy powder changes without prior notice.Operating temperature: paint, bearing bush of bronze Performance is indicated in accordance with-10 to +80 °C - piston rod: ground and polished IEC546 and IEC770 recommendations. AISI 316 acid-resistant steelAir consumption - piston and 0-rings: silicone rubber- for 3 bar supply pressure: (max. 80°C). 15 litres/min (at STP) Connections- for 6 bar supply pressure: - 1/4-18NPSF female threads. 25 litres/min (at STP)Max. error of adjustment: ± 2 %. Satron Instruments Inc., P.O.Box 22, FIN-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 131 6/01Optical measurement 10.12.2013Satron VO optical analyzer for turbidity and solid content measurement ........................... BA200Satron VC Optical Consistency Transmitter ......................................................................BCs220Hygienic Satron VO is designed for process Satron VO is connected to process withindustry e.g. food and beverage for turbidity and hygienic couplingsolid content measurement.Large variety of process couplings e.g.hygienic, flushed, PASVE® ensure compatibilityfor a wide application range. The Satron VO issimple to use and easy to calibrate from thesmart user interface.VO is robust and reliable Satron quality.The analyzer communicates digitally using the Optical analyzer Satron VO is available also with remote display.Satron VC is an optical consistency transmitter.It is suitable for all pulps consisting of a singlegrade, in consistency range of 0 ... 7%:n Cslocated mainly within the mechanical pulpprocesses (SWG, TMP, PWG ja CTMP).Typical applications are measurements toscreens, outlet from latency removal chest,screen rejects and many others. Satron Instruments Inc., P.O.Box 22, FIN-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 132

Index 133 rBeAv.290.06SATRON VO Turbidity and solids content sensor 8.6.2016SATRON VO turbidity and solids content analyzer issuitable for the measurement of different liquids. Sa-vings can be obtained by using SATRON VO analyzerin process industries, e.g. the use of clean water can beminimized, the time used for the cleaning (CIP) will beshortened, the use of the end product (in dairy applica-tions: milk) and the use of cleaning materials needed inthe process can be optimized. The transmitter communi-cates digitally using the HART® protocol.TECHNICAL SPECIFICATIONSMeasuring range and span Viton® and NBR. Current output2See Selection Chart. Housing with PLUG DIN 43650 con- Internal power supply nector, code H0S: Current output 2 has same ground asZero and Span adjustment Housing: AISI303/316, Seals: Viton® binary IOZero elevation: Calibrated span is and NBR. Maximum load 400 Ωfreely selectable on the specified range PLUG connector: PA6-GF30 jacket, Range 3.5...23 mAdepending from the desired option. Silicone rubber seal, AISI316 Factory setting 4...20 mAThis can be made by using keyboard retaining screw. External power supply(display option) or HART®275/375 Current output 2 is galvanically isolatedcommunicator. Connection hose between sensing element and housing Maximum supply voltage 35 VDCDamping Codes L and R : Range 3.5...23 mA- Time constant is continuously PUR signal cable or hose protected Factory setting 4...20 mA with PTFE/AISI316 braiding Maximum load, See picture below adjustable 0.01 to 60 s. Maximum isolation voltage 100 VDC CalibrationRepeatability For customer-specified range with Process connections- 0.1% from maximum span. minimum damping. (If range is not - With G1 connecting thread specified, transmitter is calibrated for - Tri-Clamp 25/38 and 40/51Temperature limits maximum range.)Ambient: -30 to +80 °CProcess: 0 to +100 °C / +140 °C (VOF) Electrical connections Protection class: See Selection chart.-5 to +100 °C / +140 °C (VOM & VOD) Housing with PLUG connector, code WeightShipping and storage: -40 to +80 °C. H0S: Housing with PLUG DIN43650 Connector type DIN 43650 model AF; connector (H0T ): 0.9 kgOutput 3-wire (3W), 4-20 mA Pg9 gland for cable; wire cross-section Housing with M12 0.5 to 1.5 mm2. connector (H0S ): 0.9 kgSupply voltage Housing with M12 connector, code H0T: Housing with displayNominal 24 VDC, (21,6 - 27,6V) M12 plug connector (N0S & N0T): 1.3 kg Housing with display, code N0S: Remote Housing (L): 2.5 kgHumidity limits 0-100 % RH Connector type DIN 43650 model AF; Remote sensor (R): 2.5 kg Pg9 gland for cable; wire cross-sectionEMC directive 2004/108/EC 0.5 to 1.5 mm2.- EN 61326-1:2005 Housing with display, code N0T:CONSTRUCTION M12 plug connectorMaterials:Sensing element 1): AISI316L, Dup- I/O-connections 35 Vlex (EN. 1.4462), Hast. C276/C22, or bout1-3 50 mATitanium Gr2. Relay, grounding contact 10 µASurface quality: Polished Ra <0,8µm Maximum voltageLens: quartz glass, Safir glass or Maximum currentPC plastic Maximum leakage currentCoupling 1): AISI316L, Duplex (EN1.4462), Hast.C276 or Titanium Gr2 bin1-3 OFF Min. load using HART®-Other sensing element materials: NC (no connection) ON communication 250 RAISI316, SIS 2343. 0...2 V R max = Supply voltage -5 VPressure class: Minimum values for switch in use I max- PN40 Voltage 16 V- Test pressure -1 to 30 bar Current 4 mA I max = 20,5 mA Leakage current 1 mA I max = 22,5 mAHousing with display, (when the alarm current 22,5 mA iscodes N0S & N0T: Current output1 3.5...23 mA on)Housing: AISI303/316, Seals: Nitrile- Range 600 Ω Current output 2rubber and Viton®, Maximum load External power supplyNameplates: Polyester Factory setting 4...20 mA 1) Parts in contact with process mediumHousing with M12 connector, codeH0T: Housing: AISI303/316, Seals: Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index 134 rBeAv.290.06SATRON VO Turbidity and solids content sensor 8.6.2016Dimensions and Housing types VOM 20048 25 G1A H0T-Housing 240159 49.5 25 6.2 110 G1A PG9 N0S-Housing 120 200 48 25 G1A 95 90 L-Housing PG9 std. Standard = PVC 10 meter

Index VO Turbidity and solids 135 sensor rBeAv.290.06 content SATRON 8.6.2016 Tri-Clamp 25/38 ja 40/51 64 25VOM with Tri-Clamp process connections, codes TA and TB G1A 190 60 NR Housing Standard = 10meter PVC 132VOM with remote sensor, housing type code R

Index VO Turbidity and solids 136 analyzer rBeAv.290.06 content SATRON 8.6.2016Dimensions and housing type VOF H / B1-housing L / B1-Housing Standard = 15 meter VOF with valveDimensions and housing type VODFor easy installation the VOD is standard equipped with Tuchenhagen Type N but is is availablewith many different process connections. The process pipe is NOT included.Contact Satron for other possibilities, the picture above is a VOD equipped with G1\" process con-nection, and a pipe with 51 Tri-clamp.

Index VO Turbidity and solids 137 analyzer rBeAv.290.06 content SATRON 8.6.2016Instructions and spare parts that are according and within the 3-A applianceWelding the coupling 46 - 03These instructions apply to hygienic welded couplings; welding the G1 Welding Sequence Polished Ra <0,8standard coupling is described here as an example. Welding assistant M1050420• Place the coupling in the mounting hole as shown in Fig. 1‑4. Makesure the leakage detection port is down. Then weld with several runs soto prevent the coupling’s oval distortion and tightness problems.The inside welding must be cleaned, and polished with an end result ofRa <0,8• The analyzer must be out of the coupling while the coupling iswelded.You can use the shut‑off plug shown in Fig. 1‑5 to shut thecoupling. The plug protects the coupling’s sealing face and permits thestarting of the process without the transmitter.• It is always recommendable to use the welding assistant (M1050450)while welding the coupling to prevent any distortions due to heat.• Do not make weld grounding via any analyzer's body!Mounting the analyzer on the couplingProcedure• Make sure that the coupling’s sealing face is clean.• Remove the orange protective plug from the analyzer head.• Insert the analyzer in a straight line into the coupling, so that the guide groove on the transmitter aligns with the stop pinon the coupling. The analyzer settles into position when the groove and pin are aligned, and will be prevented from rotating inthe coupling.When inserting the analyzer, be careful not to damage the edge of the lens on the edges of the coupling or on theend of the stop pin!• Lock the transmitter in position by screwing the hex nut fully home. Finger tightness is sufficient to tighten the sealing faces.However, we recommend final tightening with a tool to eliminate the effect of vibration and other such factors. Apply 60±20Nm torque.Do not use sealing tape etc. on threaded connection!Spare partsNo. Part name Order code Note1 O-ring EPDM 80031720 3A 18-03 Class II (Do not exceed above 8% fat content). 3A 18-03 Class I1 O-ring FPM (Viton®) 80011720 3A 18-03 Class I1 O-ring FFPM(Kalrez®) 80041717 2 Sticker T13252153 Plug cover DIN43650 T13250034 Plug cover M12 T13250055 38/G1\" Welding adapter M1050577A5 45/G1\" Welding adapter M548101A6 Tuchenhagen / Varivent DN25 M1050090A6 Tuchenhagen / Varivent DN50 M1050091A6 Tuchenhagen / Varivent DN65,5 M1050092A7 Tri-clover 25/38 ISO2852 M1050206A7 Tri-clover 40/51 ISO2852 M1050222A7 Tri-clover 63.5 ISO2852 M1050224A

Index 138 rBeAv.290.06 Turbidity and solids content analyzer SATRON VO 8.6.2016Housing with display, code N Wiring Housing with M12-connector, code HTKeyboard :Esc = Press Esc move back towards the top of the main menu. = Use the UP arrow key to move up on the current menu level or to increase the selected parameter value. = Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value.Enter = Press ENTER to move to a lower level in a menu or to accept a command or parameter valueWiring WiringHousing with PLUG DIN43650-connector, code HS Housing with PLUG DIN43650- and M12-connector, test connector box, code HT & HS

Index VO Turbidity and solids 139 analyzer rBeAv.290.06 content SATRON 8.6.2016Wiring WiringHousing with display and PLUG DIN43650-connector, Housing with display and M12-connector, code NTcode NSWiringRemote electronics housing with display, code L

Index VO Turbidity and solids 140 analyzer rBeAv.290.06 content SATRON 8.6.2016Selection ChartAdjustability Span, min Span, max VOM 1000 FTU 5000 FTUVOF(*) 50 FTU 1500 FTUVOD 50 FTU 15 00 FTU Process temperature limits N Normal version -5...+100 °C (VOM & VOD), 0...+100 °C (VOF) H(**) High temperature -5...+140 °C (VOM & VOD), 0...+140°C (VOF)Output S 4-20mA DC/HART® for use with 230VAC 50Hz J 4-20mA DC/HART® for use with 110VAC 60Hz Material of Body Lens Seal 3A 18-03 wetted parts 2 AISI316L 2 Sapphire glass 1(***) EPDM Class II 3 Hast. C 276 4 Spinel 2 FPM (Viton®) Class I 6 Titanium Gr2 8 Duplex (EN 1.4462) 3 FFPM (Kalrez®) Class I 9 Peek Housing type N Housing with display and pushbuttons H Housing with, no display, (only one mA output) L Remote electronics housing with display Probe type 0 No remote probe R Remote measuring probe (not available with L housing), IP68 Connection type S DIN43650 with PG9, IP66 T M12, IP67 V PG9 (always with L housing), IP66 Cable Material 0 No VOD, L or R selected 1 PUR cable. 2(*) AISI316L braided PTFE hose. 3 Steel reinforced PUR hose. 4 PVC cable Cable length 0 No VOD or L, R option selected 1 5 M. 3 15 M. (PUR std.) 5 25 M. 2 10 M. (PVC std.) 4 20 M. ... Light source 2 365nm 4 540nm 6 640nm 8 950nm 3 460nm 5 580nm 7 880nm Process connections G1 Standard G1A thread + Oring TA Tri-Clamp 25/38 (ISO 2852) TB Tri-Clamp 40/51 (ISO 2852) TN Tuchenhagen \"N\" type DN50 HX (*) Fixed mounting tube, (specify length) B1 (*) G1A ball valve insertion. Extension 19cm diameter ø 24mm BX (*) G1A ball valve insertion. Extension by request diameter ø 24mmDocumentationCalibration certificate AE EnglishInstallation and operating instructions IE English IF Finnish FR FrenchMaterial certificates0 No material certificateMC1 Raw material certificate without appendices, in accordance with SFS-EN 10204-2.1 (DIN 50049-2.1) standardMC2 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-2.2 (DIN 50049-2.2) standardMC3 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-3.1 B (DIN 50049-3.1 B) standard* Not EHEDG certified & Not within the 3A approval** Only in combination with Quartz, Sapphire lens and Kalrez Seals. And only 880nm*** Do not exceed above 8% fat content. We reserve the right for technical modifications without prior notice. 46 - 03 HART is the registered trademark of HART Communication Foundation. Pasve is the registered trademark of Satron Instruments Inc. Hastelloy is the registered trademark of Haynes International. Viton is the registered trademark of DuPont Down Elastomer. 3-A is a registered mark owned and administered by 3-A SSI.

Index VC Optical Consistency 141 BCrse2v2. 06 Transmitter SATRON 13.06.2016SATRON VC is an optical consistency transmitter. It is suitable for all pulpsconsisting of a single grade, in consistency range of 0…7%Cs locatedmainly within the mechanical pulp processes (SWG, TMP, PWG andCTMP). Typical applications are measurements to screens, outlet from la-tency removal chest, screen rejects and many others. The Satron VC canprovide an accurate and reliable consistency measurement without needfor regular maintenance.TECHNICAL SPECIFICATIONSMeasuring range and span Device enclosure, code K: Range 3.5...23 mASee Selection Chart. EN 1.4301 (AISI304) Factory setting 4...20 mAZero and Span adjustment Maximum load, See picture belowZero elevation: Calibrated span is Calibration Maximum isolation voltage 100 VDCfreely selectable on the specified range For customer-specified range withdepending from the desired option. minimum damping. (If range is not Process connectionsThis can be made by using keyboard specified, transmitter is calibrated for - With G1 connecting thread(display option) or HART®275/375 maximum range.)communicator. Protection class: See Selection chart.Damping Electrical connections- Time constant is continuously Housing with PLUG connector, code Weight H0S: Housing with M12 adjustable 0.01 to 60 s. Connector type DIN 43650 model AF; connector (H0T ): 1.3 kgRepeatability Pg9 gland for cable; wire cross-section Housing with display- 0.01% Cs. 0.5 to 1.5 mm2. (N0S & N0T): 1.7 kgTemperature limits Remote Housing (L): 2.9 kgAmbient: -30 to +80 °C Housing with M12 connector, code H0T: Remote sensor (R): 2.9 kgProcess: 0 to + 140 °C M12 plug connector Device enclosure (K) 6,2 kgShipping and storage: -40 to +80 °C.Output 3-wire (3W), 4-20 mA Housing with display, code N0S:Supply voltage and permissible load Connector type DIN 43650 model AF;- 24 VDC, -10 %, + 15 %, 100 mA Pg9 gland for cable; wire cross-section- 115/230 VAC, -15% ... +10% (device 0.5 to 1.5 mm2. enclosure) Housing with display, code N0T:Humidity limits 0-100 % RH M12 plug connector Device enclosures (with display), code K: - PG13,5 inlet, 3 pcs - The sensor signal M12 plug connector.EMC directive 2004/108/EC I/O-connections 35 V- EN 61326-1:2005 bout1-3 50 mA Relay, grounding contact 10 µACONSTRUCTION Maximum voltageMaterials: Maximum currentSensing element 1): AISI316L (EN Maximum leakage current1.4404), Duplex (EN. 1.4462), Hast.C276 (EN 2.4819), or Titanium Gr2. bin1-3 OFFSafir glass NC (no connection) ONCoupling 1): AISI316L (EN 1.4404), 0...2 VDuplex (EN 1.4462), Hast.C276 (EN2.4819) or Titanium Gr2 Minimum values for switch in use Voltage 16 VPressure class: Current 4 mA- PN25 Leakage current 1 mAHousing with display, Current output1 3.5...23 mA Min. load using HART®-codes N0S & N0T: Range 600 Ω communication 250 WHousing: AISI303/316, Seals: Nitrile- Maximum load R max = Supply voltage -5 Vrubber and Viton®, Factory setting 4...20 mANameplates: Polyester I maxHousing with M12 connector, code Current output2H0T: Housing: AISI303/316, Seals: Internal power supply I max = 20,5 mAViton® and NBR. Current output 2 has same ground as I max = 22,5 mAConnection hose between sensing binary IO (when the alarm current 22,5 mA iselement and housing Maximum load 400 Ω on)Codes L and R : Range 3.5...23 mA Current output 2PUR signal cable or hose protected Factory setting 4...20 mA External power supplywith PTFE/AISI316 braiding External power supply Current output 2 is galvanically isolated 1) Parts in contact with process medium Maximum supply voltage 35 VDC Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index VC Optical Consistency 142 BCs220 Transmitter SATRON 13.06.2016Wiring WiringHousing with M12-connector, code HT Housing with M12-connector, test connector box, code HTWiringRemote electronic in the device enclosure. Powersupply 115/230 V 50/60 Hz, code K.Only housing type L and probe type R with display.WiringRemote electronics housing with display, code L

Index VC Optical Consistency 143 BCs220 Transmitter SATRON 13.06.2016 312Ø36 20Ø24 Dimensions Satron VCT 373 Ø36 Ø25 Dimensions Satron VCF 95 159 110 Ø6,2 PG9 std. 90 120Standard 15 m Satron VC with L-housing

Index VC Optical Consistency 144 BCs220 Transmitter SATRON 13.06.2016Selection ChartAdjustability Span, min Consistency RangeVCT 1% Cs 0...7% CsVCF 0,5% Cs 0...0,5 CsProcess temperature limits N Normal version 0 ...+140 °C30...+200 °COutput S 4-20mA DC/HART® Material of Body Lens Seal wetted parts 2 AISI316L (EN 1.4404) 2 Sapphire glass 1 EPDM 3 Hast. C 276 (EN 2.4819) 2 FPM (Viton®) 6 Titanium Gr2 (EN 3.7035) 3 FFPM (Kalrez®) 8 Duplex (EN 1.4462) Housing type N Housing with display and pushbuttons (only with remote probe \"R\") H Housing with, no display, (only one mA output) L Remote electronics housing with display Probe type 0 No remote probe R Remote measuring probe (not available with L housing), IP68 Connection type T M12, IP67 U M12 & USB (only with N housing), IP67 V PG9 (always with L housing), IP66 Cable Material 0 No, L or R selected 1 PUR cable. 2 AISI316L braided PTFE hose. 3 Steel reinforced PUR hose. 4 PVC cable 0 No L or R option selected Cable length 2 15 meter Light source 7 880nm Process connections B1 G1A ball valve insertion. Extension diameter ø 24mm Device enclosure K Remote electronic in the device enclosure. Power supply 115/230 V, IP66. Only housing type L and probe type R with display.Documentation IE English IF Finnish FR FrenchCalibration certificate AE EnglishInstallation and operating instructions Material certificates0 No material certificateMC1 Raw material certificate without appendices, in accordance with SFS-EN 10204-2.1 (DIN 50049-2.1) standardMC2 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-2.2 (DIN 50049-2.2) standardMC3 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-3.1 B (DIN 50049-3.1 B) standard We reserve the right for technical modifications without prior notice. HART is the registered trademark of HART Communication Foundation. Hastelloy is the registered trademark of Haynes International. Viton is the registered trademark of DuPont Down Elastomer.

Index VCA Optical Total 145 Transmitter + Ash BCs230 Consistency rev. 2 SATRON 13.06.2016The SATRON VCA is a multichannel optical transmitter. It is suitable fortotal & filler (ash %) consistency measurements in majority of the pulp &paper applications.TECHNICAL SPECIFICATIONSMeasuring range and span CalibrationSee Selection Chart. For customer-specified range withZero and Span adjustment minimum damping. (If range is notZero elevation: Calibrated span is specified, transmitter is calibrated forfreely selectable on the specified range maximum range.)depending from the desired option.This can be made by using keyboard Electrical connections Process connections(display option) or HART®275/375 Housing with PLUG connector, code - With G1 connecting threadcommunicator. H0S: Connector type DIN 43650 model AF; Protection class: See Selection chart.Damping Pg9 gland for cable; wire cross-section- Time constant is continuously 0.5 to 1.5 mm2. Weight 1.3 kg adjustable 0.01 to 60 s. Housing with M12 connector, code H0T: Housing with M12 1.7 kg M12 plug connector connector (H0T ): 2.9 kgRepeatability Housing with display 2.9 kg- 0.01% Cs. Housing with display, code N0S: (N0S & N0T): 6,2 kg Connector type DIN 43650 model AF; Remote Housing (L): Temperature limits Pg9 gland for cable; wire cross-section Remote sensor (R): Ambient: -30 to +80 °C 0.5 to 1.5 mm2. Device enclosure (K) Process: 0 to + 140 °CShipping and storage: -40 to +80 °C. Housing with display, code N0T: M12 plug connectorOutput2 current outputs for Cs: Device enclosures (with display), code3-wire (3W), 4-20 mA K:Supply voltage and permissible load - PG13,5 inlet, 3 pcs- 24 VDC, -10 %, + 15 %, 100 mA - The sensor signal M12 plug connector.- 115/230 VAC, -15% ... +10% (device I/O-connections 35 V enclosure) 50 mA bout1-3 10 µAHumidity limits 0-100 % RH Relay, grounding contact Maximum voltageEMC directive 2004/108/EC Maximum current- EN 61326-1:2005 Maximum leakage currentCONSTRUCTION bin1-3 OFFMaterials: NC (no connection) ONSensing element 1): AISI316L (EN 0...2 V1.4404), Duplex (EN. 1.4462), Hast.C276 (EN 2.4819), or Titanium Gr2. Minimum values for switch in useSafir glassCoupling 1): AISI316L (EN 1.4404), Voltage 16 VDuplex (EN 1.4462), Hast.C276 (EN2.4819) or Titanium Gr2 Current 4 mAPressure class: Leakage current 1 mA- PN25 Current output1 3.5...23 mA 600 Ω Range Maximum load 4...20 mA Factory settingHousing with display, Current output2codes N0S & N0T:Housing: AISI303/316, Seals: Nitrile- Internal power supplyrubber and Viton®,Nameplates: Polyester Current output 2 has same ground as Min. load using HART®- communication 250 WHousing with M12 connector, code binary IOH0T: Housing: AISI303/316, Seals: R max = Supply voltage -5 VViton® and NBR. Maximum load 400 Ω I maxConnection hose between sensing Range 3.5...23 mA I max = 20,5 mAelement and housing I max = 22,5 mACodes L and R : Factory setting 4...20 mA (when the alarm current 22,5 mA isPUR signal cable or hose protected on)with PTFE/AISI316 braiding External power supply Current output 2Device enclosure, code K: External power supplyEN 1.4301 (AISI304) Current output 2 is galvanically isolated 1) Parts in contact with process medium Maximum supply voltage 35 VDC Range 3.5...23 mA Factory setting 4...20 mA Maximum load, See picture below Maximum isolation voltage 100 VDC Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index VCA Optical Total 146 Transmitter + Ash BCs230 Consistency SATRON 13.06.2016Wiring WiringHousing with M12-connector, code HT Housing with M12-connector, test connector box, code HTWiringRemote electronic in the device enclosure. Powersupply 115/230 V 50/60 Hz, code K.Only housing type L and probe type R with display.WiringRemote electronics housing with display, code L

Index VCA Optical Total 147 Transmitter + Ash BCs230 Consistency SATRON 13.06.2016 312 20159 Dimensions Satron VCA 110 95 Ø36 Ø24 Ø6,2 PG9 std. 90 120 Satron VCA with L-housing

Index VCA Optical Total 148 Transmitter + Ash BCs230 Consistency SATRON 13.06.2016Selection ChartAdjustability Span, min Total Consistency Range Filler consistencyVCA 1% Cs 0...12% Cs 0 ... 10% CsProcess temperature limits N Normal version 0 ...+140 °C30...+200 °COutput S 4-20mA DC/HART® Material of Body Lens Seal wetted parts 2 AISI316L (EN 1.4404) 2 Sapphire glass 1 EPDM 3 Hast. C 276 (EN 2.4819) 2 FPM (Viton®) 6 Titanium Gr2 (EN 3.7035) 3 FFPM (Kalrez®) 8 Duplex (EN 1.4462) Housing type N Housing with display and pushbuttons (only with remote probe \"R\") H Housing with, no display, (only one mA output) L Remote electronics housing with display Probe type 0 No remote probe R Remote measuring probe (not available with L housing), IP68 Connection type T M12, IP67 U M12 & USB (only with N housing), IP67 V PG9 (always with L housing), IP66 Cable Material 0 No, L or R selected 1 PUR cable. 2 AISI316L braided PTFE hose. 3 Steel reinforced PUR hose. 4 PVC cable Cable length 0 No L or R option selected 2 15 meter Light source 4 880nm / 640 nm / 530 nm 7 880nm / 640 nm / 465 nm Process connections B1 G1A ball valve insertion. Extension diameter ø 24mm Device enclosure K Remote electronic in the device enclosure. Power supply 115/230 V, IP66. Only housing type L and probe type R with display.Documentation IE English IF Finnish FR FrenchCalibration certificate AE EnglishInstallation and operating instructions Material certificates0 No material certificateMC1 Raw material certificate without appendices, in accordance with SFS-EN 10204-2.1 (DIN 50049-2.1) standardMC2 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-2.2 (DIN 50049-2.2) standardMC3 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-3.1 B (DIN 50049-3.1 B) standard We reserve the right for technical modifications without prior notice. HART is the registered trademark of HART Communication Foundation. Hastelloy is the registered trademark of Haynes International. Viton is the registered trademark of DuPont Down Elastomer.

Index VCB Optical Brightness 149 BCrse2v5. 03 Transmitter SATRON 13.06.2016The SATRON VCB is a multichannel optical Brightness transmitter, suit-able for Brightness measurement in majority of the chemical and mechani-cal pulp, recycled and paper machine applications.TECHNICAL SPECIFICATIONSMeasuring range and span CalibrationSee Selection Chart. For customer-specified range with minimum damping. (If range is notZero and Span adjustment specified, transmitter is calibrated forZero elevation: Calibrated span is maximum range.)freely selectable on the specified rangedepending from the desired option. Electrical connections Process connectionsThis can be made by using keyboard Housing with PLUG connector, code - With G1 connecting thread(display option) or HART®275/375 H0S: Protection class: See Selection chart.communicator. Connector type DIN 43650 model AF; Weight Pg9 gland for cable; wire cross-section Housing with M12Damping 0.5 to 1.5 mm2. connector (H0T ): 1.3 kg- Time constant is continuously Housing with M12 connector, code H0T: Housing with display M12 plug connector (N0S & N0T): 1.7 kg adjustable 0.01 to 60 s. Housing with display, code N0S: Remote Housing (L): 2.9 kg Connector type DIN 43650 model AF; Remote sensor (R): 2.9 kgTemperature limits Pg9 gland for cable; wire cross-section Device enclosure (K) 6,2 kgAmbient: -30 to +80 °C 0.5 to 1.5 mm2.Process: 0 to + 140 °CShipping and storage: -40 to +80 °C. Housing with display, code N0T: M12 plug connectorOutput2 current outputs for Cs:3-wire (3W), 4-20 mASupply voltage and permissible load Device enclosures (with display), code- 24 VDC, -10 %, + 15 %, 100 mA K:- 115/230 VAC, -15% ... +10% (device - PG13,5 inlet, 3 pcs - The sensor signal M12 plug connector. enclosure)Humidity limits 0-100 % RH I/O-connections 35 V bout1-3 50 mAEMC directive 2004/108/EC Relay, grounding contact 10 µA- EN 61326-1:2005 Maximum voltage Maximum currentCONSTRUCTION Maximum leakage currentMaterials:Sensing element 1): AISI316L (EN bin1-3 OFF1.4404), Duplex (EN. 1.4462), Hast. NC (no connection) ONC276 (EN 2.4819), or Titanium Gr2. 0...2 VSafir glassCoupling 1): AISI316L (EN 1.4404), Minimum values for switch in useDuplex (EN 1.4462), Hast.C276 (EN Voltage 16 V2.4819) or Titanium Gr2 Current 4 mA Leakage current 1 mAPressure class:- PN25 Current output1 3.5...23 mA Range 600 ΩHousing with display, Maximum loadcodes N0S & N0T: Factory setting 4...20 mAHousing: AISI303/316, Seals: Nitrile-rubber and Viton®, Current output2Nameplates: Polyester Internal power supply Current output 2 has same ground asHousing with M12 connector, code binary IO Min. load using HART®-H0T: Housing: AISI303/316, Seals: Maximum load 400 Ω communication 250 WViton® and NBR. Range 3.5...23 mA R max = Supply voltage -5 V Factory setting 4...20 mAConnection hose between sensing External power supply I maxelement and housing Current output 2 is galvanically isolatedCodes L and R : Maximum supply voltage 35 VDC I max = 20,5 mAPUR signal cable or hose protected Range 3.5...23 mA I max = 22,5 mAwith PTFE/AISI316 braiding Factory setting 4...20 mA (when the alarm current 22,5 mA isDevice enclosure, code K: Maximum load, See picture below on)EN 1.4301 (AISI304) Maximum isolation voltage 100 VDC Current output 2 External power supply 1) Parts in contact with process medium Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Index VCB Optical Brightness 150 BCs250 Transmitter SATRON 13.06.2016Wiring WiringHousing with M12-connector, code HT Housing with M12-connector, test connector box, code HTWiringRemote electronic in the device enclosure. Powersupply 115/230 V 50/60 Hz, code K.Only housing type L and probe type R with display.WiringRemote electronics housing with display, code L


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook