DATA ACQUISITION & DISTRIBUTION ACCESSORIES Backplane for Power and CommunicationCode S401-L EASY SETUP SOFTWAREDescription Plug & Play set-up software for OLED brightness display: 2,7\" Interfaces: programmable devices 1 x RS485 Modbus Master + 1 x RS485 Modbus Slave + ++ Code Description Z-PC-DINAL2-17.5 Head + 2 SlotsCode DATA RECORDER SOFTWARE S117P-1 Z-PC-DIN2-17.5 2 Slots Z-PC-DIN8-17.5 8 Slots Data acquisition Programming kit for head mount temp. Z-PC-DINAL2-35 Head + 1 Slots visualisation & transmitters. Consists of: Serial Cables, USB to Z-PC-DIN1-35 1 Slot recording software. RS232/TTL, Config. software Z-PC-DIN4-35 4 SlotsCable AccessoriesCode Description Terminal Type RJ10/ DB9FPM001420 RS232 serial cable (Z-TWS, Z-RTU, Z107, Z-LINK) RJ10/ DB25MPM001430 Modem communication cable (Z-TWS) RJ10/ DB25MPM001440 Modem and HMI communication cable (ZTWS, Z-RTU) RJ45/ RJ45PM001450 Ethernet cable-right (Z-TWS - network device) RJ45/ RJ45PM001460 Crossing Ethernet cable ( Z-TWS-PC) RJ10/ DB9MPM001530 Modem serial cable (Z-TWS, Z-RTU) Jack/ DB9FPM001601 Programming serial cable (Z-4AI-D, Z-4TC-D, Z8AI, Z-8TC, Z-4RTD2, Z-SG, Z203) DB9M/ Bolt HeadsPM002350 RS485 serial cable for Radio modem Tp-wire/ Bolt headsPM002460 RS485 serial cable TP-WIRE (Z-TWS) RJ10/ RJ10PM002470 Serial cable (Z-TWS, Z-RTU, Z107) RJ10/ Bolt headsPM002480 RS485 Serial cable (Z-TWS) DB9M/ DB9FPM002490 RS232 Serial cable - programming (Z-RTU, M-RTU, Radio Modem) DB9M/ DB9FPM002500 RS232 modem for firmware updating (ZRTU, M-RTU, Radio Modem) DB9F/ PuntaliPM002510 Serial cable for Radio Modem DB9M/ DB9MPM002520 Serial cable DB9F/ DB9FPM002530 Serial cable TRANSMITTERS Signal Isolator Transmitter Code S4X-DT-* DC Input Range DC Output Range V2: 0-5V; V3: 1-5V; *Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC V4: 0-10V; A1: 0-1mA; V2: 0-5V; V3: 1-5V; INSTRUMENTS & TELEMETRY Multi-range Input / Output selectable by solder jumper wire on inside of unit. A3: 0-20mA; A4: 4 -20mA V4: 0-10V; A2: 0-10mA; (AC/DC Workshop will set Input/Output configuration if requested on ordering) A3: 0-20mA; A4: 4 -20mA Input - 3 Wire Potentiometer Transmitter Code S4X-DT-* Supply Voltage: AC 85 – 265V/DC 100 – 330V Total Resistance - 100Ω - 10kΩ RTD (PT100) Transmitter (Isolator) Code S4X-RR-P*-A4-* DC Output Multi Range (Selectable by Dip Switch) * Add °C to code: F (0 - 100°C), D (-50 - 200°C), G (0 - 200°C) V2: 0-5V; V3: 1-5V; V4: 0-10V; * Add Supply Voltage: A = 85 - 265VAC/100 to 330 VDC or B = 20 - 60VDC A1: 0-1mA; A2: 0-10mA; A3: 0-20mA; A4: 4 -20mA Speed (Frequency Transmitter) Specifications Code Description Code Description Accuracy: ± 0.1% RO. Isolation: Input/Output/Power S4X-RT-B-2-M-A 0-100Hz Input S4X-RT-F-2-M-A 0-2Hz Input Insulation Resistance: ≥ 100MV, DC 500V Impulse Withstand Test: IEC 1000-4-5, class 4 S4X-RT-E-2-M-A 0-1KHz Input S4X-RT-H-2-M-A 0-10KHz Input Supply Volts: 85-265VAC Output Programmable: 4-20mA, 0-10V DPM 258

GENSET CONTROLLERS All controllers are DSE702 DSE331 DSE4520 DSE6120 DSE7320 suitable for 12/24VDC systems. Manual Start / Stop ATS AMF AMF AMF Code N 4 4 4 4 Application 1 4 4 6 8 Config DC Output N Config Input Dedicated N Can be Configured Can be Configured Can be Configured Oil Pressure Dedicated Y Can be Configured Can be Configured Can be Configured Coolant Temp 4 Can be Configured Can be Configured Can be Configured Remote Start Y N Config Relay Output N N N N 2 Fuel & Crank Output Y N Y Y Y Pre Heat relay Output Y N N N N Analogue Input N N 3 4 4 E-stop Input Y N Y Y Y Current Input N N Y Y Y MPU Pick-Up N Y N Y Y CANbus N N Y Y Y USB Port N N Y Y Y RS232 Port N N N N Y RS485 Port N Y N N Y Event Logging N Full 50 Events 100 Events 250 Events PC Config N Y Y Y Front Config N 180 x 116 x 42 Full Partial Partial Dimensions (mm) 84 x 72 x 35 154 x 98 140 x 113 x 43 216 x 158 x 42 240 x 181 x 42 Panel Cut Out (mm) 80 x 68 8- 35VDC 118 x 92 182 x 137 220 x 160 Supply 8 - 35VDC 8 - 35VDC 8 - 35VDC 8 - 35VDC DSE890 Accessories Code Description DSE890 Gateway for remote monitoring & control connects to DSE data server by Ethernet, GPRS, RS232 or RS485. Includes GPS functionality. Suitable for use with controllers with USB Port. DSE-GSMANT GSM Antenna DSE-GPSANT GPS Antenna Automatic Manual Key Start Transfer Switch Controller Model EAOM-36 EAOM-7 EAOM-71 ATS-10 EAOM-3 ControlsINSTRUMENTS & TELEMETRY Automatic engine Start/Stop Y Y Y Controls Fuel and stop solenoid Automatic Shutdown on fault Generator remote start Starter motor condition Y Y Y Load transfer to mains Manual generator start/ stop Alternator voltage and fre- Mains and generator Preheat (Glow Plug) quency measurement Frequency Generator Voltage/ Generator Voltage/ contactor Monitors Measurement Power Measurement Power Measurement Monitors Engine running time Load current measurement 3 Phase mains voltage Error Indication Remote Start/Stop input N 3 Phase 3 x 1 Phase Alternator voltage Fail Monitoring 3 resistive sender units Y Y Y Program parameters Low oil pressure User configurable inputs N N Y High temperature User configurable outputs 2 3 3 Over speed failure Speed sensing off Alternator 1 2 2 Charging fail Speed sensing off magnetic Y Y Y Pickup 72 x 72 RS-232 Serial Comms N YY Remote use from PC Standard Modem Comms Y Y Y 72 x 72 Display Y Y Y N Y Y Size (mm) LED LED LED 72 x 72 96 x 96 96 x 96 259 DPM

ANTI-HARMONIC PFC Anti-Harmonic PFC Plug-In Systems Code Code with kVAr at Steps Step values @400V Dimensions Comms 400V 25kVAr 50VAr H x WxD VMPH-150 VMPHC-150 150 4 2 2 1600 x 800 x 600 VMPH-175 VMPHC-175 175 4 1 3 1600 x 800 x 600 VMPH-200 VMPHC-200 200 5 2 3 1850 x 800 x 600 VMPH-225 VMPHC-225 225 5 1 4 1850 x 800 x 600 VMPH-250 VMPHC-250 250 6 2 4 2050 x 800 x 600 VMPH-300 VMPHC-300 300 7 2 5 1600 x 1600 x 600 VMPH-350 VMPHC-350 350 8 2 6 1600 x 1600 x 600 VMPH-400 VMPHC-400 400 9 2 7 1600 x 1600 x 600 VMPH-450 VMPHC-450 450 10 2 8 1600 x 2400 x 600 VMPH-500 VMPHC-500 500 11 2 9 1600 x 2400 x 600 VMPH-600 VMPHC-600 600 12 0 12 1600 x 2400 x 600 Connect ready Automatic Power Factor Correction Systems where harmful harmonics exist as caused by UPS, VSDs and other similar devices. It is always recommended that a detailed site analysis be undertaken before ordering. • Robust design for systems subjected to VTHD <7% and ITHD <20%. VTHD<14% on application. • Top, bottom and side cable entry. • Plug-in full busbar system. • Thermostatically controlled forced cooling • Door interlocked isolator with surge protection and control fuse protection. • Data acquisition option with GSM comms and PC software. Sim card required. • Each plug-in step includes: - Heavy duty 440V harmonic filtration rated capacitors with discharge resistors - Fusegear and capacitor switching rated contactor T2 - Anti-Harmonic reactor ENERGY SAVING INSTALLATIONS - COMMERCIAL & DOMESTIC Passive Power Factor Correction Power Factor Correction (PFC) is a technique of counteracting the undesirable effects of electric loads that create a power factor less than one. This range of passive (PFC) units can save 10%-20% of energy consumption. Code Description Dimensions ES100 Single Phase (2000kWh pm) 125 x 85 x 60 ES100 ES300 Three-Phase (6200kWh pm) 190 x 140 x 70D ES300 ES3001 Three-Phase (10 000kWh pm) 240 x 190 x 90D ES3002 Three-Phase (15 000kWh pm) 240 x 190 x 90D Features Technical Info The three-phase energy saver can be wired either at the DB or the incoming • Prolongs life of appliances • Single-Phase voltage: 220-240VAC 50Hz Eskom box. • Stabilise electrical current • Three-Phase voltage: 380-420VAC Note: As long as the black is connected • Available in single and three-phase • Operating temperature: 60˚C (max.) to neutral, it does not matter which of • Suitable for home, shops, offices, the other wires connect to which phase.CAPACITORS & PFCs restaurants, etc. Combination Geyser / Power Factor Protection & Surge Protection Technical Info Combination units consist of both geyser controller and passive power factor • Single-Phase voltage: 220-240VAC 50Hz (energy saving). These are parallel connection types, for single and three • Three-Phase voltage: 380-420VAC phase units, some available fitted with surge protection. • Surge Protection: 65kA Code Description Dimensions ES100-GC 170 x 200 x 85mm Single phase power + Geyser controller ES100-GC-SS Single phase power + Geyser + Surge protection 170 x 200 x 85mm ES100-2GC-SS Single phase power + 2 x Geyser + Surge protection 170 x 200 x 85mm Red (or Brown) White (or Brown) wire to ES300-GC Wire to Red Phase Secondary side of Geyser ES300-GC-SS C/B (or Isolator) ES300-2GC-SS Three phase power + Geyser controller 210 x 215 x 100mm White (or green/ Yellow) Wire to Phase Red Wire to Geyser Three phase power + Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue wire to Ditto for other controllers Three phase power + 2 x Geyser + Surge protection (3ph+N) 210 x 215 x 100mm Blue phase Black Wire to Neutral265 T

THERMOSTATS Code Contact Rating Control Clima – Series 6-30˚C Surface mount CLIMA ML 16A Heating onlyMLI ML CLIMA MLI 10A Heating only + on/off switchMLW CLIMA MLW 10A Heating – Off – Cooling CLIMA FC 10A Heating – Off – Cooling, Speed 1/Speed 2CLIMA FC Rio – Series 6-30˚C Surface mount VN650800 15A Heating only Heating/Cooling + on/off switch VN652400 10A Heating/Cooling + on/off switch + on lamp VN653200 10A Room Thermostats 10-30°CBEL-B1 BEL4118-A2 A7700 A7700 16A Heating only 10 - 30˚C with on/off 20A isolator mounting into stan-BEL-B2 BEL4118-B1 BEL4118-E1 dard 4 x 2 box. Max switching 3600W 16A Heating only 10-30°C with on/off switch mounting into BEL4118-A2 75 x 75mm box 16A Heating only with on/off switch mounting into 75 x 75mm box c/w BEL4118-B1 remote sensor with 3m cable, adj between 10 - 50˚C. BEL4118-E1 16A LCD Electronic Thermostat. heating only 10-30˚C with 7 day timer programmable. 6 times, 6 temperature settings per day. Remote sensor with 3m cable BEL-B1 – 75 x 75 x 32(D)mm Flush Mount Wall Box BEL-B2 – 86 x 86 x 32(D)mm Surface Mount Box Thermostats for Air Conditioning Systems (Surface Mount) Temperature Control 10-30˚C BEL-3538/03A 5A 3 Speed Fan Switch with 10-30°C Temp. Control and on/off switch BEL-3538/03LA 5A As BEL-3538/03A with Digital Temp. DisplayBEL-3538/03A BEL-3538/03LA Digital Room Thermostats NEO-ML 7A Heating only for surface mounting. Temperature regulation 5 - 35˚C DECO-TERMO 8A Heating and cooling, control with two programmable temperature levels, mounts into 75 x 75mm box. Temperature range 0-40˚C TEMPERATURE CONTROLSDECO-TERMO NEO-ML Thermostats - c/w Timing Functions NEO ERA ERA 5A Heating and cooling with comfort and saving settings. Daily timing. DECO CRONO NEO 5A Temperature range 10 - 40˚C. DECO-CRONO 8A Heating and cooling with 2 temperature settings and anti-ice setting. Weekly timing with 8 programs . Surface mounting. Temperature range 0 - 50˚C Heating and cooling with 2 temperature settings and anti-ice setting. Weekly timing with 8 programs. Mounts into 75 x 75mm box. Temperature range 0 - 40˚C. TC 266

PID TEMPERATURE CONTROLLERS Universal 4 Digit Temperature Controller – Dual Indication (full PID controller) Control Relay & Alarm Relay TZN4S-14R TZ4ST-14R TZN4M-14R TZ4L-14R TZ4H-14R TZ4W-14R 4-20mA output & Alarm Relay TZN4S-14C TZ4ST-14C TZN4M-14C TZ4L-14C Control Relay + 2 Alarm Relays TZN4ST-24R TZN4M-24R – TZ4H-14C TZ4W-14C Size (H x W) - 48 x 48mm 48 x 48mm 72 x 72mm / 96 x 96mm – TZ4W-24R 96 x 48mm 48 x 96mm Features • S V2 input for oven door interlock Specifications • Indicating accuracy of ±0.3% ( F - S) • 2 x 7 digit LED displays: • D ual PID function selectable fast response • M ulti-volt Supply: 100 to 240VAC PV (Process Value) RED • C onsumption: 5VA SV1 (Set Point Value) GREEN PID action (PIDF) or slow response PID action (PIDS) • C ontrol Relay output: C/O 3A @ 250VAC • Control: ON/OFF, P, PI, PD, PIDF, PIDS control • S ampling time: 250ms • M easure range: multi-range and pre-scalable • Input types: T C (J, K, R, S, T,...) RTD (PT100...) 0-10V, 1-5V, 4-20mA Connection Diagram for TZN4S Connection Diagram for TZN4M Connection Diagram for TZ4H Control O/P ‘C’ TEMPERATURE INDICATORS Indicator Indicator 5 Sensor Input Indicator Indicator IndicatorTEMPERATURE CONTROLS Code: PT100 T3NI-400P T4YI-400P T4WM-400P MTR10-599P SG-781*P SG-681*P Code: J – T4YI-500J T4WM-500J MTR10-999J SG-781*J SG-681*J Code: K – T4YI-1200K T4WM-1200K MTR10-999K SG-781*K SG-681*K Size 36 x 72mm 48 x 96mm 72 x 72mm 96 x 96mm Supply Volts 24 x 48mm 100-240VAC 110-240VAC 34 x 76mm 12-24VDC 230VAC 110-230VAC Temperature Range – – *Add Temp Range to code: – – 100, 200, 400°C 267 TC

DIGITAL TEMPERATURE CONTROLLERSAccuracy ±0.25%Read Rate 3/secCode ESM4410-*-230 ESM4420-** ESM-4430-** ESM-7730-** ESM4435-** Voltage 230VAC 230VAC, 115VAC, 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC 100-240VAC / 24VAC/DC On/Off On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID Control Method On/Off, P, PI, PD, PID On/Off, P, PI, PD, PID Auto / Manual Auto / Manual PID Tuning ― 4 digit 10mm (red) 4 digit 10mm (red) Process Display 3 digit 10mm (red) Auto / Manual Auto / Manual 4 digit 8mm (Green) 4 digit 8mm (Green) Set Value Display Display during set-up Sensor Input * Select when ordering 4 digit 10mm (red) 4 digit 10mm (red) J, K, R, S, T,B,E,N, PT100 J, K, R, S, T,B,E,N, PT100 Process Inputs N/A 0-50mV/5V/10V, 0/4-20mA N/A 4 digit 8mm (Green) 4 digit 8mm (Green) 0-50mV/5V/10V, 0/4-20mA Process Supply ― 0-50mV/5V/10V, 0/4-20mA Heating/Cooling √ J, K, R, S, T, PT100 J, K, R, S, T,B,E,N, PT100 √ √ Programmable Alarms ― √ √ N/O Relay 7A@250VAC N/A N/A N/O Relay 5A@250VAC Output 1 ― N/O Relay 5A@250VAC N/O Relay 5A@250VAC ― ― 0-50mV/5V/10V, 0/4-20mA N/O Relay 5A@250VAC 0/4-20mA / 0/2-10V Output 2 48x48x116mm SSR (20mA@12VDC) 48x48x116mm Output 3 √√ 3 readings/sec 72x72x87.5mm 3 readings/sec Size √√ 3 readings/sec Read Rate N/O Relay 5A@250VAC N/O Relay 5A@250VAC N/O Relay 5A@250VAC N/O Relay 5A@250VAC SSR (20mA@12VDC) SSR (20mA@12VDC) 48x48x116mm 48x48x116mm 3 readings/sec 3 readings/sec* Add to code J = J-Type, K = K-Type, P = PT100, N = NTC** Add to code 230 (230VAC), 240 (100-240VAC), 115 (115VAC), 24 (24VAC/DC)Features• User friendly installation and operation. • Adjustable hysteresis for greater flexibility• Universal Input TC, RTD, mVDC, VDC,mADC (excl ESM4410) • Text based Function menu for ease of set-up• Automatic or manual PID tuning for greater control • Dual Display of process temperature and set value (excludes ESM4410)• Adjustable PID cycle time for greater control • Adjustable On and Off delay on alarms SCR HEATER ELEMENT REGULATORS Voltage Control for Heaters Single Phase (230V) Code Current KW Ultra fast Code Current KW Ultra fast Fuse Fuse SG-027 27A 6 30A SG-100 100A 22 100A SG-057 57A 12.5 60A SG-132 132A 29.3 160A SG-162 162A 36 160A Three Phase (400V) Code Load KW Ultra fast Code Load KW Ultra fast Current Fuse Current Fuse 16.5 SG-3100 100A 66 100A SG-325 25A 33 25A SG-3130 130A 86 160A TEMPERATURE CONTROLS SG-350 50A 49 50A SG-3160 160A 105 160A SG-375 75A 75ABenefits Specifications Output Voltage: 0-100% Input Signal: 4-20mA, 0-20mA, 1-5VDC. 0-5VDC Constant- Voltage Characteristics: Output accuracy 1%• Small size, saving space Control System: Phase control Ambient Temperature: -10/50°C Humidity 90% RH below• H igh accuracy and fast response Insulation Resistance: 500VDC (10g ohms) VR1: Min V output Ads.• Eliminates contactor noise VR2: Max V output Ads.• Extends heater life Connection Diagram• High efficiency, no maintenance­• M aintains stable process temperature­ TC 268

TEMPERATURE CONTROLLERS ON/OFF Analogue Setting Analog Setting Thumbwheel Setting Control Analogue Setting & Deviation & Full Scale Display & Digital Display Display Size 96 x 48 – – – – – KE-861* – Size 72 x 72 KE-714* KE-724* – KE-742* KE-771* – Size 96 x 96 KE-612* KE-622* KE-632* KE-642* KE-671* KE-861/A* – 72 xW7i2th/ 9a6laxrm96 – – – – KE-771/A*/KE-671/A* Range & Probe Digital *Add temperature 100, 200, 400 or 600°C and Probe type PT100., J or K e.g. KE-724 200K Higher Range ‘K’ – – 800 & 1200°C – Technical Specifications Connection Diagram Supply: 110/220VAC Output: Relay 1C/O Input: Thermocouple 5A@250V K, J and PT100 Hysteresis: 2,5% full scale Accuracy: 1% of full scale Alarm: 10% of full scale Control: On/Off action Digital 1 Set Point Digital 2 Set Point Thumbwheel 1 Set Point Analogue 1 Set Point ON/OFF Control Size 72 x 72mm 72 x 72mm 48 x 48mm 48 x 48mm 34 x 76mm Probe PT100 TR-48*P *100, 200, 400°C MTR11-150PTC* Probe J & K VM6251 -99° to 999°C VM6269 -99° to 999°C TP-48*P *100, 200, 400°C TR-48*J *100, 200, 400°C TR-48*K *100, 200, 400°C – VM6392 -99° to 999°C VM6400 -99° to 999°C TP-48*J *200, 400°C Reversed 8 pin P3G-08 – Technical Specifications TP-48*K *200, 400°C • Supply: 230VAC Supply: 24 or 230VAC • D irect/Reverse PWM & All supplied complete with * C/W Probe Input: Thermocouple K, J Neutral zone operation Range: 50-150°C & PT100 Y-50 mounting bracket Spare Probe: PTC150 Accuracy: 1% of full scale Specifications: Output: Relay C/O 8A@250V Connection Diagram Supply voltage 110-240VACTEMPERATURE CONTROLS • Min/Max Alarms Hysteresis 2,5% full scale • D ifferential or Hysteresis Relay output: 1 C/O @ 2A p­ rogrammable 250VAC Panel-mount or 8 pin plug-in. When using 2-wire PT100 Probe, short circuit terminals 4 and 5 Connection Diagram Transparent cover for 72 x 72 Adaptor for 72 x 72 to 96 x 96 VJ4482 VJ4458 Supply Volts269 IP54 TC For blind temperature controllers, see pages 6 & 24.

TEMPERATURE PROBES Thermocouples NOTE: Wire Colours - J: Red & Blue, K: Red & Green, PT100: 2 x White, 1 x Red PVC Cable Probe size 100mm x 5.0 Ø Cable: 1.5m Steel CableProbe size 100mm x 5.0 Ø Thread size 1/4” or 1/2” Steel Braided Cable PVC Coated Probe:Cable: 1.5m Cable: 1.5m 1/2” Thread 150mm x 5.0 ØProbe Thermo- Temp Cable Screw Temp Code Description Com­Type couple Range Type Type Range Head Large pression Type Code Type Head Clamp Code CodePT100 TC-P 100D 100°C PVC TC-P/S* 400°C TC-P2 CABLE 200°C PVC coated Grey KSE-P KEN-P 1/2” Brass TC-P4 CABLE 400°C Steel braided CC-02B Std 1/4” thread 200°C PVC KSE-J KEN-JPT100 TC-P 200D* 400°C Steel KSE-K KEN-K 1/4” BrassPT100 TC-P STEEL CC-04B 400°C Steel TC-J/S* 400°C TC-J CABLE 400°C Steel braided Std ¼” thread 400°C Steel TC-K/S* 400°C TC-K CABLE 400°C Steel braided 1/2” S/SteelType J TC-J* CC-02SType K TC-K* *Specify 1/4” or 1/2” 1/4” S/Steel*Specify 1/4” or 1/2” CC-04S Head Mount Temperature Transmitter - Programmable & Loop Powered Thermocouple Connectors Code T121 Description Programmable using Programming Kit S117P-1 (see page 258) Input: PT100, Ni100, PT500, PT1000, J, K, R, S, T, B, E, N thermocouples Power Supply: 7 - 30 VDC. Current Output: 4/20 or 20/4mA (2 wire) Female Male Resolution: 2μA (>13bit). Response Time: >1s Over range fault output: 102.5 - 105% full scale FPL-PT100 MPL-PT100 Connection by spring terminals: (wire size 0.2 - 0.25mm² ) FPL-J MPL-J Size: 20mm x 43.7mmØ FPL-K MPL-K Temperature Transmitter (2 wire) - Fits into Head Type KEN-P/J/K Code Temperature Range Specifications Output Signal: 4 - 20mA DC TRT-PT100* 50, 100,150, 200, 400°C Power Supply: 10 - 36VDC Accuracy: ±0.15% F.S. (PT100) TRT-J* 100,150, 200, 400, 600°C ±0.5% F.S. (J & K)v Installation TRT-K* 100,150, 200, 400, 600, 1000, 1200°C example *Add Temperature range to code TEMPERATURE SWITCHES Electronic Temperature Switch Mechanical Temperature High Performance Temperature Switch TEMPERATURE CONTROLS - with fixed Switching Point IP66 - with Power relay, with fixed Switching Point IP67 - with programmable LED Display IP65 • 12 - 24VDC, 48VAC • 24VDC • 12 - 30VDC • 4A Switch rating • 30A Switch rating • 100mA • M12 4-pin PlugProbe Size: Probe Size: Cable:Ø6 x 0.75mm (up to 40 Bar) Ø10mm (up to 100 Bar) 1.5m open leadsLength: 25mm Length: 28mm 1/2\" thread SL6410* S6410*Code Output Temp Code Output Temp Code Output Temp Range Range RangeTC5400-* 2 x PNP -50 to 125°C SL6410-*-** NO/NC + 40 to 200°C S6300-* NO - 20 to 120°CTC5410-* 1 x PNP & 1 x 4-20mA -50 to 200°C S6410-*-** NO/NC + 40 to 200°C - - -*Specify 1/4\" or 1/2\" thread **Add Temperature: 040, 060, 080, 100, 120, *Add Temperature: 040, 050, 060, 070, 080, 140, 160,180, 200°C 090, 100, 110°C e.g. SL6410-1/4-040 e.g. S6300-040 *Specify 1/4\" or 1/2\" thread TC 270

TEMPERATURE CONTROLLERS IP64 Size: 76 x 36mm Cutout: 71 x 29mm Display: 3 Digit + Sign Code KLT11BB-J (J Probe) KLT11D KLT11D2 KLT12D KLT22D KLT32 KLT11BB-K (K Probe) Range -50 to 150°C J = 0 to 700°C Supply K = 0 to 999°C 230VAC, 110VAC, 24VAC/DC or 12VAC/DC to be specified Probe (excluded) J or K Probe PTC or NTC PTC or NTC PTC20±2°C / PTC05±0.5°C Output relay Program Selectable Program Selectable Program Selectable N/O 16A Control, C/O 5A Function 1 Relay C/O 16A N/O 20A 16A N/O Control Defrost, N/O 8A Fan Alarm C/O 16A N/ O 8A C/O Defrost Communication Control Control for compressor, Card Output (KL-KEY) 2 Alarm set points Control C ontrol Control & fan & defrost Connection Diagram Defrost – Yes – – – – Yes Yes Yes Yes KLT11D KLT12D 16A KLT11D2 KLT22D 16A 8A Specifications • Cooling or heating • Cooling or heating • 1 or 2 Probe selectable • 1 or 2 Probe selectable • Inside alarm buzzer • High & low value set point • Designed for refrigeration • D esigned for refrigeration • Accuracy 1% • A ble to program 23 • A ble to program 52 ­different parameters, i.e. ­different parameters, i.e. hysteresis, defrost time hysteresis, defrost time Temperature Indicators Accessories (Probes c/w 1.5m cable) Code TKTZ DT-101S Code Description Range -50 to +99°CTEMPERATURE CONTROLS Supply 230VAC or 115VAC -40 to +70°C PTC20 PVC Cable. Accuracy ± 2°. Range -50°C / 105°C Probe PTC20 (included) Battery included PTC05 PVC Cable. Accuracy ± 0.5°. Range -50°C / 105°C Size 62(W)x29mm(H) 1.1m cable (included) NTC20 PVC Cable. Accuracy ± 1°. Range -50°C / 105°C 48(W)x28mm(H) KLRS485 KLGATEWAY Communication Accessories - for KLT Range Code Description KLRS485 Isolated RS485 Communication Module for KLT Range Controllers KLRTRL Interface Cable between Controller & KLRS485 KLUSB485 RS485 - USB Interface between PC and KLT Devices KLGATEWAY RS485 - Ethernet Interface between KLT Controller Installation and KLNetCenter through Lan or Internet KLUSB485271 TC

HUMIDITY & TEMPERATURE CONTROLS Humidity Sensors Combined Humidity & Temperature Sensors IP30 1.5m cable length 1.5m cable lengthCode VN8736 KLSH03 TH-102W TH-101D TH-103SSupply VoltageRange 9-30VDC / 12-24VAC 5VDC 12/24VDC 12/24VDC 12/24VDC 20-90% RH 10-90% RH 0-100°C / 0-100%RH 0-100°C / 0-100%RH 0-100°C / 0-100%RHOutput 4-20mA or 0.1-1V 1 to 3VDC 4-20mA (2-wire) 4-20mA (2-wire) 4-20mA (2-wire)HUMIDITY CONTROLLERS TEMPERATURE & HUMIDITY CONTROLLER IP65 Features Code KLTH43 • R ed display for temperature and greenCode DPM-RH-* KLH11RH Size 134 x 105mm ­display for humidity Cutout Size 130.5 x 100.5mm • T emperature control can 76 x 36 x 60D mm Supply 230VAC be ON/OFF, n­ eutral zoneSize 72 x 72 mm 110VAC or 230VAC Temp. Range -50°C to 150°C (0.5%) or refrigerationSupply 110VAC or 230VAC 0-1V, 1-3V KLSH03, Hum. Range 0-100% RH (5%) • Second temperatureInput* 4-20mA (VN8736) / 1-3V Temp 2 x PTC05 ±0.5% or PTC20 ±2% probe can be used for 0-100% RH Probes defrosting controlRange 0-100% RH • Humidity control can be Differential or Hysteresis (excluded) Humidity 1 x (0-1V) / (0-3V) 4-20mA probe ON/OFF or neutral zone.Settings Hysteresis Adj. Relay C/O 8A 4 SPDT Relays 8A @ 250VAC • H umidity probe (0-1V) /Output Relay C/O 8A Outputs (0-3V) / (4-20mA) select­ able by programme Display Red for temperature; Green for humidity • Resolution: Temp: 0.1°C Humidity: 1%Indicators Indoor In/Outdoor Wireless Weather Centre Thermometer Thermometer Code CTH-608 CTH-609 WS1170 Wall or Table mount (back stand built-in) • Display: in °C or °F • Temperature Ranges: Memory store and recall of max/min temp. and humidity Indoor: Clock: 12/24hr Format, Alarm, Calendar Function 0°C to 60°C (built in) Outdoor:CTH-608 Battery: 1 x AAA size (included) -40°C to 65°C (wireless x1)CTH-609 • H umidity Range: LCD Size 80 x 70mm 1%RH-99%RH • A ccuracy: ±1°C Temperature Display in \"C\" or \"F\" selectable Battery: 3 x 1.5V AA (excluded) Sensor: 2 x 1.5V AAA (excluded) WS1170 Range: -10ºC to 50ºC ±1ºC Indoor: -14ºF to 122ºF±1.8ºF Range: -50ºC to 70ºC ±1ºC Outdoor: -50ºC to 70ºC ±1ºC TEMPERATURE CONTROLS -58ºF to 158ºF±1.8ºF - -58ºF to 158ºF±1.8ºF Humidity: 10% to 99%RH±1% Frost Warning: -1 to 4ºC Humidity: 20% to 99%RH±1% Temperature & Humidity Temperature Only Indicator Glass Temperature Thermometer Indicator Indicator TH-920 TH-922 CS-120Size mm: 360H x 395W x 100D • 0-100°C Temp • 0-120°C/20-180°F • 0-100% Humidity • 1/2” BSP thread • Length: 150mm • Supply 85-265VAC • Sensor TH-101/2/3 • Size mm: 200H x 395W x 100D or VN8736 (see above) • 0-100°C Temp • Input: 4-20mA • Supply 85-265VAC • Digit size mm: 100H x 60W • Input: TC-P 100D TC 272

DIGITAL DEFROSTING & TEMPERATURE CONTROLS Temperature Controllers for Walk-in Freezers and Cooling Displays Size: 71 x 28 x 71mm Cut Out: 71 x 29mm Display: 3 Digit/Sign Code TC-900RI-CL TC-900RI-P TC-920RI TC-940RI-P Range -50 to +75˚C/ -58 to 167 F Supply -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F -50 to +75˚C/ -58 to 167 F Probe 115 or 230VAC ±10% 90-264VAC 115 or 230VAC ±10% 115 or 230VAC ±10% 2 x SB19 2 x SB19 3 x SB19 2 x SB19 Relay Output NTC Sensor (Inc.) NTC Sensor (Inc.) NTC Sensor (2 Inc.) NTC Sensor (Inc.) N/O 5A Refr N/O 16A Comp N/O 5A Refr Coms N/O 5A Fans N/O 5A Fans N/O 5A Fans N/O 16A Comp 3A N/O Alrm Function N/O 5A Defrost N/O 8A Defrost N/O 3A Defrost N/O 5A Defrost Connection diagram Yes No N/O 5A Fans Control/ Ref/ Defrost No Control/ Ref/ Defrost Yes Control/ Ref/ Defrost Control/ Ref/ Defrost Remote management software R/ deaayl t&imienteclroncakl,buapttetory8 defrost Code: SITRAD Refrigeration Frozen Size: 71 x 28 x 71mm Display: 2 Cut Out: 71 x 28mm Digit/Sign Display: 3 Digit/Sign Code MT-512RI MT-512RI-LOG TC-900RG2 Range -50 to +75˚C/ -58 to 167 F Supply 0 to 50˚C/ 32 to 122˚F -50 to +75˚C/ -58 to 167 F Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10% 1 x SB19 2 x SB19 Relay Output 1 x SB19 NTC Sensor (Inc) NTC Sensor (Inc) Coms NTC Sensor (Inc) N/O 16(8)A/ 250VAC 1HP N/O 16(8)A/ 250VAC 1HP Function N/O 16(8)A/ 250VAC 1HP Connection diagram N/C 8A/ 250VAC N/C 8A/ 250VAC N/C 8A/ 250VAC Yes No Remote manage- Yes ment software Refrigerate Control/ Comp/ Defrost/ FANS Code: SITRAD Refrigerate/Display coolers Temperature & Humidity Size: 71 x 28 x 71mm With a timer for cooling & defrost times Cut Out: 71 x 28mm Temperature Controls Display: 3 Digit/SignTEMPERATURE CONTROLS Code MT-516RVTI MT-518RI MT-530SUPER Range -50 to 105˚C Supply -50 to 105˚C -50 to 105˚C Probe 115 or 230VAC ±10% 115 or 230VAC ±10% 115 or 230VAC ±10% 1 x SB56 NTC Temperature and Relay Output 1 x SB19 1 x SB19 NTC Sensor (Inc) NTC Sensor (Inc) Humidity Sensor (Inc) Coms N/O 8A/ 250VAC 1HP N/O 8A/ 250VAC 1HP 3 x N/O 5A @ 250VAC Function N/O 8A/ 250VAC N/O 8A/ 250VAC Connection diagram Temp/Humidity/Aux Yes No Yes Remote manage- Temperature Controller with over/under voltage protection Temperature Controller/Cooling or Heating ment software Temperature/ Humidity Controller Code: SITRAD For milk cooling Includes For air conditioning For data centres & genl. aircon 273 Cyclic Timer 0-999min TC

POWER MONITORS TIMERS TEMPERATURE DISPLAYInstrument for Scheduler with real- The big therm is ameasuring and time clock that digital thermometer.monitoring the allows configuring The dimensions andmajor parameters up to four events design of thisregarding energy for each weekday, instrument allow thequality on three- through the defini- temperature forphase electrical tion of start and end long-distanceinstallations times for each one. visualization.Code PHASE LOG PLUS PROGS-1 TIC-17GSupplyControl Range 85 to 265VAC (50/60Hz) 85 to 265VAC (50/60Hz) 110 or 220VAC (50/60Hz)Current 90-500VAC 24hr, 365 days -55 - 90˚CDimensonsOperation Temp 5A/ 250VAC 1/8hp 10A (resistive load) NTC with cable 1,5mCommunication 71 x 28 x 71mm 70 x 28 x 60mm 90 x 44 x 27mmApplication 0-60˚C 0 - 50˚C 0-50˚C No NoFeatures yes, RS-485 Electrical panels Ovens, injection machine, defrost control Refrigerating equipment greenhouse, ovens, Other multi-phase equipment climatized rooms. Over/ Under voltage (Adjustable) Remote Management Software Phase Failure & Phase Sequence Code SITRAD-* Data Logger Per Phase More than just automation, sitrad innovates in the management of cooling, heating, air conditioning, and solar heating systems by means of its most distinguishing feature: connectivity. The user can continuously evaluate, configure and store data on temperature, humidity and pressure, among others • *Local: must be installed in the computer to which the instruments are connected via interface • *Remote: must be installed in the computer that will remotely manage the installation, via Internet • *Mobile: manages facilities via cell phone, communicating with the local module With mobile, the user has another option for remote management. Without using a computer, it provides even easier remote installation management. It is the connectivity allowing to take over the control, anytime, anywhere DIGITAL DEFROSTING & TEMPERATURE CONTROLS Differential Temperature Controllers for Pumped Solar Heating SystemsCode ANASOL MICROSOL RI *V6 MICROSOL II *PLUSFeatures Economy range of differential Differential thermostat for automation of Differential temperature controller forSupply temperature controller used to control pumped solar heating systems. automation of pumped solar heating the pump of solar water heating With Anti-Freeze and Overheating systems.With Anti-Freeze, Overheating applications. With Anti-Freeze function. functions. and solar back-up functions. Supplied with 2 colour coded sensors. Supplied with 2 colour coded sensors. Supplied with 3 colour coded sensors. 115-250VAC 115-250VAC or 115-250VAC or * Add \"L\" for 12-24VAC/DC * Add \"L\" for 12-24VAC/DCControl Range -50 to 105°CLoad Current 16A@ 250VAC 1HP -50 to 105°C -50 to 105°COperating Temp 16A@ 250VAC 1HP 16A@ 250VAC 1HP 0° to 50°CNo. of Sensors IP's 2 Colour Coded 0° to 50°C 0° to 50°CDimension 100 x 72.8 x 36.8mm 3 Colour Coded 3 Colour CodedConnection Diagram 71 x 28 x 71mm 71 x 28 x 71mm 115V 230V Sensor 1 Black Cable Sensor 2 Grey Cable Sensor 3 Black Cable COMMON NO NC Serial Communication RS-485 Sensor 1 Black Cable Sensor 2 Grey Cable Sensor 3 COMMON PUMP ACDC1 ACDC2 TEMPERATURE CONTROLS 115V 230V Load 230V 115V Power Sensor S1 - Black Silicone Pump Power Load Supply Panels or Solar Collector Supply Supply Load Supply To the terminal of distribution box Sensor S2 - Grey PVC Reservoir/Pool Power Supply 5-6 / 115V 5-7 / 230V TC 274

RADIO REMOTE CRANE & MACHINE CONTROL IP65 8 Button Hand Held Controllers 10 Button Hand Held Controllers With Display Code 946091-400 949190-400 946093-400 949192-400 947704-400 Functions 10 x 2 Stage Buttons 8 x 2 Stage Buttons 8 x 2 Stage Buttons 10 x 2 Stage Buttons 10 x 2 Stage Buttons Quick Stop Switch Markings Quick Stop Switch Display Quick Stop Switch Quick Stop Switch Quick Stop Switch Din Symbols Size Din Symbols LCD 02 x 64 Pixels Weight ― Symbols 1-8 Din Symbols Symbols 1-10 Features ―― ― 243 x 77 x 41mm 480grams • Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna • Battery: 3.7V / 1.8Ah • 13hr Operating Time 9 Button Hand Held Controllers Jupiter Joy-Stick Controllers With Display With Display With Display Code 947823-400 947824-400 949767-401 949768-401 949769-401 Functions 9 x 2 Stage Buttons 9 x 2 Stage Buttons 3 Directions 2 Speed 3 Directions 2 Speed 3 Directions 2 Speed Markings Display 1 x Rotary Switch (4 Pos) 1 x Rotary Switch 2 Extra controls 2 Extra controls 5 Extra controls Size Weight Quick Stop Switch Quick Stop Switch Features DIN Symbols DIN Symbols DIN Symbols DIN Symbols DIN Symbols ― LCD Display 102 x 64px ― LCD Display 102 x 64px LCD Display 102 x 64px 243 x 77 x 41mm 260 x 165 x 150mm 480grams 520grams • Output: 10mW @ 433-434MHz • Baud Rate: 9600 • Internal Antenna • Battery: 3.7V / 1.8Ah • 13hr Operating Time Jupiter Receiver - RX160 Accessories for Remotus - Hand HeldCRANE & VEHICLE CONTROLS Code 948470-800 Code 934158-000 935408-001 934157-001 No Of Outputs Code Belt Clip Vehicle Bracket Protective Bag 16: 4 C/O & 12 Open Contacts of No Of Inputs which 6 are safety relays Accessories for Jupiter 1 Analogue 0(4)-20mA or 0/2-10V Digital Inputs 1 Serial Input RS422/RS485 944204-000 947108-000 2 Opto Isolated for 24/48V AC/DC, Shoulder Strap Harness Radio Freq. 115VAC or 230VAC 50/60 Hz Mem Capacity 433-434 MHz Protection 500 Transmitters Casing IP67 Outputs For E/Stop Flame Retardent Plastic (UL 94 5VA) Antenna 2 Safety Relays: 2 C/O Contacts Size Internal Weight 277 x 217 x 115mm Supply Voltage 1.5kg Consumption 24-230VAC/24VDC Operating Temp MAX 12 VA -25 to +55°C279 For customised solutions contact ACDC Dynamics and Q refer to shortform catalogue for complete range.

AIR LINE FILTERS & REGULATORSType Filter Regulator Filter/ TC Series Treatment TC Series Treatment Triplet Regulator Oil Sprayer Dual Regulator & Air Filter/Regulator/Lubricator LubricatorCode 3/4” TF4000-06 TR4000-06 TW4000-06 TL4000-06 TC4010-06 TC4000-06 TW5000-10 TC5000-10Code 1” TF5000-10 TR5000-10 TL5000-10 TC5010-10 TADSpecifications Auto Drain Valve UW Series• Filtration: 5µm Code 3/8” TAD402-03• Applicable Pressure Range: 0-1.0MPa Code 1/2” TAD402-04• Applicable Temperature: 0-60°C• Gauge Port Size: G1/4• Material (Body): Aluminium Alloy Die-cast (Bowl): Polycarbonate (PC) SOLENOID VALVES US Series USSC USC US-10 US-25 UW-15 UW-25 UW-25 *Code US-10 * US-15 * US-20 * US-25 * UW-15 * UW-20 *Spare Coil CodeSpare Solenoid USC * UWC *c/w CoilMaterial of body USSC * UWSC *Operating methodPipe size BrassNominal diameter (mm)Applicable fluid P lunger Pilot Film Pilot LIMIT & PRESSURE SWITCHES & SENSORSPressure rangeApplicable temperature ZG3/8” ZG1/2” ZG3/4” ZG1” ZG1/2” ZG3/4” ZG1”Operating voltage rangeMinimum activating time 17 17 17 20 20 20 25 PS-02A Air, Water, Oil (50CST below) & Steam Air, Water, Oil (50CST below) 0.05 – 1.5Mpa 0 – 0.8Mpa -5 to 185°C -5 to 99°C ± 10% 0.05S *Add Voltage to Code: 12VDC, 24VDC, 24VAC, 110VAC, 230VAC Pressure Switches Pressure (Bar) Contact Rating Pipe Thread Code Min. Max. (NPT) PS-02B 1.4 2.8 2 Pole 20A N/C 1/4” PS-02A 2.8 2.1 3.5 2 Pole 20A N/C 1/4” PS-02A 3.5 2.8 4.3 2 Pole 20A N/C 1/4” PS-02A 4.3 3.5 5.6 2 Pole 20A N/C 1/4” PS-02B 5.6 4.9 7.2 2 Pole 20A N/C 1/4” PS-02B 7.2 CON 280

PROCESS GAUGES Type Stainless Steel Case Robust Liquid Filled Economic Code PBB- * - ** - *** - **** - ***** PBG- * - ** - *** - **** - ***** PBN- * - ** - *** - **** - ***** Connection This gauge is ideally suited to most For heavy duty services where vibration or For non-corrosive liquids and gases on light A-Bottom Connection industrial applications where high accuracy shock of medium would cause excessive wear duty service in more corrosive environments. D-Rear Connection and durability is required. Gauges are on a dry gauge or corrosive ambient Applications include coastal application for available with either brass/bronze internals, conditions prevail. Applications include valve positioner and regulators, swimming Case all stainless steel internals, or Manel hydraulic equipment, mining equipment and pool pumps and stationary irrigation systems. Internals Bourdan tube and socket with stainless irrigation. Range (Max) steel movement. Steel Black, Powder Coated Temperature 304 SS, Crimped Bezel Brass Accuracy Brush finish 304 SS, Bayonet Bezel Brass 6000 kPa Configuration Available with either Brass/Bronze, or SS 6000 kPa -25℃ to 60℃ -25℃ to 60℃ 1.6% @ FSD Thread 6000 kPa 1.6% @ FSD Code Fitting -25℃ to 60℃ 02 1/4 NPT 100Ø 1% @ FSD / 63Ø 1.6% @FSD 04 1/2 NPT 12 1/4 BSP Conn. A + D A+D Conn. A + D A+D Conn. A 14 1/2 BSP Add to code * Connection A (Bottom) & D (Rear) A (Bottom) & D (Rear) A (Bottom) only ** Add size (mm) 63 100 63 only 54 only *** System material BB&SS BB BB **** Thread size 02, 12 02, 04, 12, 14 02, 12 02, 12 ***** Add pressure 100kPA, 160kPA, 250KPA, 400kPA, 600kPA, 1000kPA, 1600kPA, 2500kPA, 4000kPA, 6000kPA. Other ranges available on request. Process Gauges Accessories Steam Line Piping Valve Dairy Seals Chemical Seals Flanged SealsLIMIT & PRESSURE SWITCHES & SENSORS NW40 NW50 Code U-TYPE Code VG ISOLATE Code NW40-* NW50-* XWD4-* NFD01-* Code PIGTAIL Isolation valves and Material Grade 316 SS 316 Stainless Steel Grade 316 SS gauge cocks to isolate Max Pressurer • Steam line piping should pressure from gauge. Gauge Port 40 MPA 150 Mpa 150 Mpa be installed on all live Application steam applications to Equipped with a facility 1/4\", NPT or BSP 1/4\" or 1/2\", NPT or BSP 1/4\" and 1/2\", NPT protect the gauge from to vent the gauge. Thread Size the high temperatures Suitable for use with Is used in health and Is used in applications Flanged seals, one for encountered. gases, liquids and dairy application, can be where the process fluid continuous use for safety • Available in either \"pigtail” vapours. used for pulp/paper. (medium) is corrosive or concerns. or “U-type” configurations viscous (could even Cleanout type for easy for installation on horizontal Material - Brass For non-corrosive liquids contain waste particles) cleaning with flushing or vertical line respectively and gases on light duty and could clog the connections available. Material - Steel. service in more corrosive instruments internals. environments. *Add Thread Type to Code: 02, 04 *Add Thread Type to Code: *Add Thread Type to Code: 02, 12 02, 04,12,14281 RHE

PRESSURE TRANSMITTERS Standard IP67 Mini Model IP67 Pressure Transmitter IP65DIN PlugTo be orderedseparatelyEDS-STCode SMP136-* SMP132-* PT1X*P**R01Pressure RangeOutput * Add to code 2, 5, 10, 20, 50 or 100 bar • Accuracy to better than 0.5%FSSupply Voltage (including linearity and repeatability)Media Temperature 4 - 20mA • Transducer rated at 50 million cyclesThread • Metalwork made of Type 316Overload Pressure 12 - 30VDC Stainless SteelAccuracy • Protected against reverse voltageConnector ˗25°C to 85°C and overvoltageSeal Material • Protected against noise on the supply lineHousing Material G1/4, SS316 • Wide supply range, 8 to 36VDC -Size (Ø x L)mm allows a wide range of load resistanceApplication 1.5 x Full scale • Transducer is temperature compensated by means of laser-trimmed resistors 0.5%F.S. • Operating temperature range from 0℃ to +85℃ DIN (4 PIN) Plug • Internal Trimpots for field calibration Fluoro Elastomer Aluminium Ø27mm x 97mm Ø48mm x 74mm Machine Tools Petroleum Industry Mechanical Engineering Environmental Chemical Industry Machine tools Dry Gases etc Sewage plants etc Hydraulics Hi-Temperature IP67 Flush Seal IP67 General Purpose IP68DIN Plug SMP135-* SMP134-* LLS2.5/5 LLS10/15 GENERAL SPECIFICATIONS To be ordered 3 bar 10 bar Output: 4 - 20mA separately * Add to code 2, 5, 10, 20, 50 or 100 bar 4 - 20mA Excitation: 8 - 36V DC 15 - 30VDC Accuracy (BFSL):< 0.5% FS EDS-ST 4 - 20mA 0°C - 70°C Compensated Temp. Range: 0º to 85º C LIMIT & PRESSURE SWITCHES & SENSORS 1/4\" Gas Temperature error zero: < -0,02% FS / KCode 12 - 30VDC 6 bar 20 bar Temperature error span: < -0,01% FS / KPressure Range 1.5%F.S. (0-70ºC)Output ˗60°C to 200°C ˗25°C to 85°C Ingress protection: IP65Supply Voltage Cable 5m Cable 15m Burst pressure: 2.5 x FS (except whenMedia Temperature M20X1,5 G1/2 (50 & 100Bar = G3/4) Ceramic indicated)Thread (SS316) SS314 Wetted Parts/Connection: 316 StainlessOverload Pressure 1.5 x Full scale steel, ceramic, Nitrile (Specify media whereAccuracy Ø30mm x 54mm Nitrile is not compatible)Connector 0.5%F.S. Pumps / Fluids WIRING CONNECTIONSSeal Material Compressors 1 Red: + UsHousing Material Gas 2 Black: - VsSize (Ø x L)mm 3 Yellow: GNDApplication * ** Code Transducer Range Code Fitting DIN (4 PIN) Plug 0010 1 Bar 02 1/4” NPT 0040 4 Bar 04 1/2” NPT SS316 Fluoro Elastomer 0060 6 Bar 12 1/4” BSP Aluminium 0100 10 Bar 14 1/2” BSP 0160 16 Bar 0250 25 Bar Other options available 0400 40 Bar Ø48mm x 219mm Ø27mm x 70mm 1000 100 Bar 4000 400 Bar Steam / Heated process Machine tools Thermal energy process Mechanical Engineering Other options available Process control Hydraulics/Pneumatics PRODUCT TRANS PRESSURE FITTING RANGE DUCER RANGE P ** R01 PT1X * CON 282

ELECTRONIC AIR PRESSURE SENSORS & SWITCHES Electronic Air Pressure Controllers Code Code Cut-out- Cut-in- Maximum Repeat pressure pressure pressure Accuracy Relay Output Supply 4-20mA Supply Supply at 25°C 0.2-2 bar 0-50% of 1C/O only Output 0.5-10 bar cut-out 1-16 bar pressure EDR-2 230VAC – – 3 bar +/-0.05 bar – – EDI-10 12-30VAC 25 bar +/-0.1 bar EDR-16 230VAC EDI-16 12-30VDC 25 bar +/-0.15 bar Note: 4mA = 0 bar. 20mA = measuring range highest value EDR & EDI • Accurate compressor and process control • User friendly menu programming • Electronic pressure switch with integrated ­pressure sensor • Relay output – (All models) 6A @ 250VAC • Push-on connector for air tube inlet (Festo PAN 6 x 16mm) • 0-10V Analogue output and digital LED display • Adjustable relay set point and hysteresis • Fail safe (EDRA only) • Din rail mounting Electronic Pressure Sensor Code NPN N/O PSA-01 PSA-1 Code PNP N/O PSA-01P PSA-1P Pressure Range 0-100.0kPa (0-1.000 Bar) 0-1000.0kPa (0-10.00 Bar) Specifications 12V to 24VDC ± 10%. 50mA • Hysteresis: 1 digit (2 digit/psi) fixed Max. 100mA 30VDC • R epeat Error: ± 0.2% F.S. ± 1 digit • Power Supply: 1V-5VDC ± 2% F.S. • Response Time: Selectable 2.5ms, 5ms, • O utput Current: kPa, kfg/cm2, bar, psi 100ms, 500ms • Analog Output: 30x30x38.5(D)mm • Short Circuit Protection: Built-in • Pressure Display: • Size: Accessories Code Description PS-01 Bracket for panel mount. Size of cutout 36X36mm PS-02 Clear protection cover 2-Wire Electronic Air Pressure Transducer IP65 • Accurate process control • Service friendly plug-in electrical connection • 2-Wire device installs directly on the machinery • Converts measured pressure to 4-20mA • Ceramic sensor technology Code Description Pipe Measuring Output Repeat Supply Thread Range Accuracy EDS-16 Transducer External G1/4\" 0-16 bar 4-20mA +/-1% 11-30VDC EDS-ST Connection plug DIN3852 Form E EDS-16 Pressure Switch Diagrams The co-ordinates of a cut out and cut in pressure must lie within the shaded area for the switch to be suitable for the application.LIMIT & PRESSURE SWITCHES & SENSORS EDS-ST283 CON

PRESSURE SWITCHES Direct Motor Switching Ui = 500V Cut-out Contacts Features Pipe Code Code with Pressure (Bar) AC3 Thread Auto-Off Min Max Diff Switch MDR1 F or use with air, water, mineral oils, sea/salt water, butane, acetylene, carbon dioxide etc. Medium temperature: Air -5 to +80°C. Water +70°C max. IP44 Contacts 2 N.C. Ith 20Amps, 2,2/4kW @ 240V. Bursting strength Pz >35 Bar.MDR1/11 2.5 6.0 Adj 1ph 4.0kW For Pumps only Factory set 1.5-3 Bar 1/4\" BSP MDR1/6/DIF – 2.5 11.0 2 Bar 1ph 2.2kW For Compressor only Factory set 6-8 Bar 1/4\" BSP MDR1/11 MDR1/11/EA MDR2 F or use with air, water. Medium temperature: Water +80°C max. IP44 Contacts 2 N.C. Ith 20Amps, AC3 2.2kW @ 240V. Bursting strength Pz >35 Bar. 1.5 7.0 Adj 1ph 2.2kW 1/4\" BSP MDR2/6 – 4.0 12.0 Adj 1ph 2.2kW 1/4\" BSP MDR2/11 MDR2/11/EAMDR1/11/EA MDR4 F or use with air, water. Medium temperature: Water +80°C max. IP44 Contacts 3 N.C. Ith 20Amps, AC3 5.5kW @ 400V. Bursting strength Pz >35 Bar. 1.5 6.0 Adj 3ph 5.5kW 1/2\" BSP MDR4/6 MDR4/6/EA4 4.0 11.0 Adj 3ph 5.5kW 1/2\" BSP MDR4/11 MDR4/11/EA4 6.0 16.0 Adj 3ph 5.5kW 1/2\" BSP MDR4/16 MDR4/16/EA4 MDR5 F or use with air, water, sea water, petrol, diesel, natural gas, butane, carbon dioxide etc. Medium temperature: Air -5 to +80°C. Water +80°C max. IP54 Contacts 3 N.C. Ith 25Amps, AC3 5.5kW @ 400V. Bursting strength Pz >40 Bar.MDR2/6 or /11 2.0 8.0 Adj 3ph 5.5kW 1/2\" BSP MDR5/8 2.5 16.0 Adj 3ph 5.5kW 1/2\" BSP MDR5/16 Fitted with Unloader Valve, Overload & Start/Stop Buttons MDR5/8 Range: 2 .4-4.2A 1/2\" BSP MDR5/16/4.2MDR2 or 4/EA or /16 4.0-7.0A 1/2\" BSP MDR5/16/7 6.1-10.3A 1/2\" BSP MDR5/16/10 9.0-14.0A 1/2\" BSP MDR5/16/14 11.0-18.0A 1/2\" BSP MDR5/16/18 With OverloadAccessories Spare Covers for MDR5 Description Code Unloader Valve Code plain H5-COVER EV1S For MDR1 EV1S with On/Off buttons H5K-COVER EV2 For MDR2 EV2 EV4 For MDR4/43 EV4 H5-COVER H5K-COVER EV5 For MDR5 EV05 Control Circuit Switching 10Amp 250VAC Ui = 400V IP65 MDR43 F or use with a wide range of mediums including air, water, oils and refrigerants. LIMIT & PRESSURE SWITCHES & SENSORS Medium temperature: Air -25 to +100°C. Water +100°C max. IP54MDR43 Cut-out Pressure (Bar) Contacts Bursting Pipe Thread Code Min Max Diff Strength 1 NO + 1 NC 1/4\" BSP MDR43/3 0.5 3.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4\" BSP MDR43/6 2.5 6.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4\" BSP MDR43/11 5.0 11.0 Adj 1 NO + 1 NC Pz >60 Bar 1/4\" BSP MDR43/16 8.0 16 Adj Pz >60 BarMDR-F MDR-F H igh pressure range – for use with air, water, sea water, petrol, diesel, natural gas butane, propane, nitrogen etc. Medium temperature: +70°C max. IP54 0.5 8.0 Adj 1 C/O 10A Pz >40 Bar 3/8\" BSP MDR-F8H-S 1.0 16.0 Adj 1 C/O 10A Pz >48 Bar 3/8\" BSP MDR-F16H-S 2.0 32.0 Adj 1 C/O 10A Pz >64 Bar 3/8\" BSP MDR-F32H-S 8.0 60.0 Adj 1 C/O 10A Pz >120 Bar 3/8\" BSP MDR-F60HH-SSee page 283 for pressure diagrams. CON 284

LIMIT SWITCHES Steel Type AH8 (28mm) IP65 • Contact: NC & NO 5A • Cable entry: Rubber Grommet Code AH8111 AH8112 AH8122 AH8104 AH8107 AH8108 AH8166 AH8101 AH8169 180° Tilt Wobble 180° Tilt Steel Type WL5 (40mm) IP65 180° Tilt Maintained Pull Switch • Contact: NC & NO 10A • Cable entry: 20mm Hole centres: Pushbutton Pushroller Rollerball 20-22mm Code WL5101 WL5102 WL5103 WL5104 WL5106 WL5107-2 WL5108-2 WL5105 AP5-T98 Compact Enclosed Type AH-7 IP65 Code AH-7100 AH-7110 AH-7310 AH-7311LIMIT & PRESSURE SWITCHES & SENSORS Code AH-7312 AH-7120 AH-7140 AH-7121 Mounting holes Code AH-7141 AH-7124 AH-7144 Specifications • Service life: Mechanically: 1 000 000 operations min Electrically: 100 000 operations min • Contact resistance: 25mΩ max (initial) • Current rating: 10A @ 250VAC C/O • Insulation resistance: 100MΩ min (at 500VDC) • Dielectric strength: 1 000VAC 50/60Hz for 1 min285 HIG

LIMIT SWITCHESPlastic Type AP1 – 30mm Width IP65• EN50047• Contact: NC & NO 10A@24VAC 3A@240VAC• Cable entry: M20x1.5Code AP5T11 AP5T13 AP5T31 AP5T41 AP5T51 AP5T52 AP5T71 AP5T91 AP5T92Plastic Type BP1 – 40mm Width IP65• EN50041• Contact: NC & NO 10A@24VAC 3A@240VAC• Cable entry: M20x1.5Code BP5H12 BP5H19 BP5H33 BP5H43 BP5H53 BP5H54 BP5H91 BP5H92 BP5H93Plastic Type DP1 – 50mm Width IP65• C ontact: 1N/O & 1NC 10A@24VAC 3A@240VAC• M20x1.5 Cable entry• 2 x cable entriesCode DP5T11 DP5T13 DP5T31 DP5T41 DP5T51 DP5T52 DP5T71 DP5T91 DP5T92 LIMIT & PRESSURE SWITCHES & SENSORSMetal Pre-Wired • Type EM1 30W x 50H (mm) IP67 • Type EM2 33W x 70H (mm) IP67• IEC 947-1• E N60947-1• Contact: 1N/O & 1N/C 5A@24VAC 1A@240VAC• Cable: 1mEM2 mounting holes EM1 mounting holes EM1G11Z EM1G12Z EM1G14Z EM1G21Z EM1G22Z EM1G24Z EM1G41Z EM1G42ZCode side cable EM2G11Z EM2G12Z EM2G14Z EM2G21Z EM2G22Z EM2G24Z EM2G41Z EM2G42ZCode bottom cable HIG 286

MICRO SWITCHES General purpose Z-type Code Z15G-1701 Z15G-1702 Z15G-1703 Z15G-1704 Code Z15G-1744 Z15G-1300 Z15G-1305 Z15G-1306 Code Z15G-1307 Z15G-1705 Z15G-1308 Z15G-1318 Mounting holes Specifications Terminal Cover for • Contact resistance: 15mΩ max (initial) Z-type Micro Switches • Insulation resistance: 100MΩ min (at 500VDC) • Dielectric strength: 1 000VAC 50/60Hz for 1 min Z15G-1307 • Service life: Mechanically: 1 000 000 operations p/min 50mm Electrically: 100 000 operations p/min • Current rating: 15A @ 250VAC C/O Type VS Micro switch (High mechanical life) 27mm Code VS15P01C VS15P02C VS15P03C VS15P04C Low torqueLIMIT & PRESSURE SWITCHES & SENSORS Code VS15P05C VS15P06C VS15P07C P-CS-71 Push Buttons Specifications Contact resistance: 15mΩ max (initial) Fits onto VS15P01C Micro Switch Hole Size 10mm Insulation resistance: 100MΩ min (at 500VDC) Dielectric strength: 1 000VAC 50/60Hz for 1 min Service life: Mechanically: 1 000 000 operations p/min Electrically: 100 000 operations p/min Current rating: VS: 1C/O 15A @ 250V P-CS: 1C/O 5A @ 250V Code VAQ-5-* VAQ-4-* AB6161-* AB5151-* Mounting holes HIG Hole Size 12mm *Add colour of button: ●R, ● Y, ● GN287

LIMIT & FOOT SWITCHES Heavy DutyCode 1NO + 1NC FS-1 FS-2 FS-3 FS-4 (SPDT) FS-4/DP (DPDT)Code 2NO + 2NC – – – 15A 250VACContacts 10A 250VAC (SPDT) 10A 250V (SPDT) 10A 250V (SPDT) AluminiumEnclosure material Steel cover Poly-carb Aluminium Not supplied (16mm entry)Cable/Entry PVC 0.75mm x 3 core PVC 0.75mm x 3 core PVC 0.75mm x 3 core IP54IP rating IP40 IP40 IP40 Z15G-1704Spare contact 1NO + 1NC – – –Footswitch - With locking device in neutral Steel Mounting Frames Safety Limit Switches IP67position (Pedal in the up position) Without foot switch 400mm WWCode 1NO+1NC FS-PS1211 (SPDT) Code Description WidthCode 2NO+2NC FS-PS1213 (DPDT)Contacts 10A 250VAC PD-1000 For 2 foot 350mm CodeEnclosure material Shock resistant ABS switches EDR-6-1-22 EDR-6-1-27 EDR-6-1-32 700mmIP rating IP65 For 4 foot 1NO + 1NC (3A 230VAC)Cable/Entry Cable Entry 20mmSpare contact for Not supplied (PG16 entry) Z11 PD-1002 switches Latching limit switch manual pull to reset1NO+1NCSafety Limit Switches Keys K101 LIMIT & PRESSURE SWITCHES & SENSORS 90˚ adjustable head 360˚ fully turnable head K100Code SP5K20 SP5K120 K101 K100KeyContact K101/K100 Key fits on front or top of the limit switchesEnclosureDimensions (mm) 1NO + 1NC 3A@240VAC Order key separately IP65 Plastic body 30 x 30 x 90 – M20 entry HIG 288

ROPE PULL SWITCHES Rope Mounting holes Contacts Rope Pull Switches Pull for PL-967 1NO + 1NC Latching Housing IP65 Code Description 3A/400VAC PL-967 4kg rope pull switch Latching on rope break Rope Accessories PL-967-7.5KG 7.5kg rope pull switch PL-967-15KG 15kg rope pull switch Features Safety Rope Break Switches • Complies to IEC-947-5-1 • 1NO + 1NC Positive Action With reset SM5K98X11 SBM5K99X11 • AC-15 = 3A at 230V. ui = 690V • For cable lengths up to 6 metres Without reset SM5K96X11 SBM5K97X11 MET Not latching Weight 4.7kg 6.7kg Dimensions 30 x 30 x 143 40 x 44 x 162 M20 entry M20 entry IP Rating IP65 IP66 Enclosure Die-cast Body Die-cast Body Code PWR SB209331/6 SB209332/6.5 SB209333/M8 SB209333/M10 SB209333/M12 SB209336/8 M8 Eye bolt Description Steel Wire. PVC sheathed Thimble Clamp M10 Eye bolt M12 Eye bolt Tensioner rope. 100m. Ø5mm Red. 6mm 6.5mm 8mm CONVEYORS SAFETY SWITCHES Safety Cable Pull Switches Belt Alignment Switch Speed Monitor IP67 IP67 IP65 Code SRS SRT ED400 Switching Capacity SPDT x 2 10A@250VAC SPDT x 2 10A@250VAC Action Force 49 ± 9.8n 3.4-5.4N.m Specifications (5±1kgf.m) (0.35-0.55kgf.m) Reset Manual Auto • Speed: 0~999rpm Ambient Temp -20-60˚C -20-60˚C • 7-seg LED display: 0~999 Enclosure Material Die-Cast Aluminium Die-Cast Aluminium • Alarm set point: 1~1999rpm Weight Approx. 2.9kg 2.9kg • Rotate direction: CW or CCW Certified for use in • Alarm: Underspeed, Standstill, Reverse, Power FailureLIMIT & PRESSURE SWITCHES & SENSORS Zone 21/22 Standard Slack Rope Ripped/Torn • Speed output: 4~20mA Conveyor Belt Conveyor Belt Conveyor Belt • Supply: 85~265VAC • Ambient Temperature: -20˚~70˚C Trip Switch Trip Switch Trip Switch • Housing: Die-cast Aluminium Conveyor Belt Alignment Switch CHW53201 Code CHW93053 CHW93058 Type 1NO/NC 2NO/2NC PT125CW5000 CHW53198 CHW53198A CHW53198B Switching Capacity 3A @ 230VAC 10A @ 230VAC CHW53197 - Protection rating IP65 Code Single End CHW53197A Cable Entries Code Double End 10A @ 230VAC HIG 1 x M20 Rated Continuous Current Protection rating IP66 Accessories for Conveyor Belt Trip Switches Cable Entries 3 x M20 Code Description 289 CHW53201 Padlock Attachment PT125CW5000 Pigtail M10 x 125mm

COMPACT RECTANGULAR/SQUARE INDUCTIVE SENSORS IP673 Wire DC Inductive Sensors 2 Wire DC InductiveNPN NO PS17-5DN PS17-8DN PFI25-8DN PSN25-5DN PSN30-10DN PSN30-15DN PSN40-20DN PS50-30DN NO OutputPNP NO PS17-5DP PS17-8DP PFI25-8DP PSN25-5DP PST17-5DONPN NC PS17-5DN2 PS17-8DN2 PFI25-8DN2 PSN25-5DN2 PSN30-10DP PSN30-15DP PSN40-20DP PS50-30DP NC OutputPNP NC – – PFI25-8DP2 PSN25-5DP2 PST17-5DC PSN30-10DN2 PSN30-15DN2 – PS50-30DN2 PSN30-10DP2 PSN30-15DP2 PSN40-20DP2 PS50-30DP2Switching distance 5mm ±10% 8mm ±10% 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10% 30mm ±10% 5mm ±10%Hysteresis Max. 10% of switching distance Standard detecting 18 x (1Ir8onx ) 25 x 25 x 1mm (Iron) 30 x 30 x 45 x 45 x 60 x 60 x 90 x 90 x 18 x 18 xtarget 1mm 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron) 1mm (Iron)Response frequency 700Hz 200Hz 300Hz 250Hz 200Hz 100Hz 50Hz Dimensions 17 x 17 x 31 26 x 10 x 49 25 x 25 x 39 30 x 30 x 53 40 x 40 x 53 53 x 53 x 35 17 x 17 x 31Protection circuit Surge protection circuit. Surge protection circuit. Reverse polarity protection. Surge Reverse polarity protection Overload & short-circuit protection Protection CircuitPower supply 12-24VDC (Operation voltage) (10-30VDC) Leakage current Max. 10mA Residual voltage Max. 1.5V Max. 4VAffection by Temp. -25 to +70°C Control output 200mA 2-100mAInsulation resistance Min. 50MΩ (at 500VDC) Operation indicator (Red LED) Indicator Ambient temperature -25 – +70°C (at non-freezing status) 2 Wire AC Inductive SensorsNO Output PSN25-5AO PSN30-10AO PSN30-15AO PSN40-20AONC Output PSN25-5AC PSN30-10AC PSN30-15AC PSN40-20ACSwitching distance 5mm ±10% 10mm ±10% 15mm ±10% 20mm ±10%Hysteresis Max. 10% of switching distance Standard detecting 25 x 25 x 1mm 30 x 30 x 1mm 45 x 45 x 1mm 60 x 60 x 1mm (Iron) (Iron) (Iron)target (Iron) Dimensions 25 x 25 x 39 30 x 30 x 53 30 x 30 x 53 40 x 40 x 53Power supply 100-240VAC(Operation voltage) (85-264VAC)Leakage current Max. 2.5mAResponse frequency 20HzResidual voltage Max. 10VAffection by Temp. ±10% Max. for detecting distance at +20°C within temperature range of -25 – +70°C LIMIT & PRESSURE SWITCHES & SENSORSControl output 5-200mAInsulation resistance Min. 50MΩ (at 500VDC)Indicator Operation indicator (Red LED)Ambient temperature -25 to +70°C (at non-freezing status)Protection Circuit Surge protection circuit AUTO DOOR SENSOR Code ADS-A Supply Voltage 24-240VAC Relay Output 0.1A @ 50VDC Mounting Height 2-2.7m (max. detecting distance: 3m) Output Delay Time 2/7/15 sec selectable by dip switch Detection Four angles for front detection area, 7.5°, 14.5°, 21.5°, 28.5° Right/Left detection area elimination functionAlso see page 316 SCA 290

MAGNETIC PROXIMITY SWITCHES IP67 Reed Contact Magnetic Switches (Cable length 2m) Nickel Plated Brass Housing SM19 SM02 SM21 SM22 Plastic Housing Nickel Plated Brass Housing Diameter/Length Code Amps Code Amps Code Amps Code Amps N/O 30VDC 250VAC N/O+N/C 30VDC 250VAC N/O 30VDC 250VAC N/O + N/C 30VDC 250VAC 0.1A 0.01A –– –– –– 8 30mm SM03 0.33A 0.04A – 0.33A 0.04A – –– – –– –– SM06 0.1A 0.01A – 1.6A 0.2A – –– 10 30mm SM05 –– SM08 –– SM09 3A 0.4A – 3A 0.4A –– – –– SM13 3A 0.4A SM14 2A 0.25A 12 40mm – – SM17 SM18 12 70mm – 18 70mm – Plastic Housing N/O N/O+N/C N/O Bistable N/O Diameter/Length 6 38mm – –– SM02 0.1A 0.01A – –– – – – 12 100mm SM19 1.6A 0.2A –– – SM21 0.4A Specifications 3A 0.4A SM22 3A Wiring Diagrams • Max Voltage: 230VAC • Switching Frequency: 200Hz • Delay on Activation: N/O + N/C • Repeatability: 2mS N/O • Temperature Limits: ± 0.3mm -20 to + 60 °C • Cable section (N/O): 2 x 0.50mm2 • Cable section (N/O N/C): 3 x 0.50mm2 Hall Effect Magnetic Proximity Switches 12-30VDC IP67 Type Code Bi-lateral Sensing Code Frontal Sensing • Voltage 12-30VDC Bi-lateral sensing • Fast 50µsec on/off Frontal sensing 12mm 18mm 12mm 18mm • LED yellow: output on • LED green: supply on Bi-lateral sensing PNP N/O - HS05B HS03F HS05F • Switching frequency 10kHz • Max output 200mA PNP N/C HS04B HS06B HS04F HS06F • Nickel Plated Brass housing • Cable length 2m Reed Contact Switch / Magnet Switching distances (mm) MG01 MG02 MG03 MG04 MG05 Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance Hysteresis Distance HysteresisLIMIT & PRESSURE SWITCHES & SENSORS Diameter 6 24 5 22 5 6 2.5 32 5 29 5 Diameter 8 24 5 22 5 6 2.5 32 5 29 5 Diameter 10 24 5 22 5 6 2.5 32 5 29 5 Diameter 12 (L=40mm) 24 5 22 5 6 2.5 22 9 20 9 Diameter 12 (L=70mm) 12 7 10 6 – – 22 9 20 9 Diameter 18 12 7 10 6 – – 22 9 20 9 Warning: The data specified in this table has an approximate value because it depends on the magnet position, the material on which it is applied ­(ferromagnetic or not) and because it is related to the magnet during the frontal approach. Reed contact sensors can also be activated laterally considering that switching distances are always influenced by the magnet position, orientation and the material on which it is applied (ferromagnetic or not). Magnets Dimensions (mm)291 DAT

SQUARE INDUCTIVE PROXIMITY SWITCHES IP67 Square 40x40mm AS80 Square 80x80mm• PBT (resin) or Nickel-plated 65 80 Brass Housing• Operating Distance 1.5 ... 15mm –• 40x40mm or 8x8mm dimension 50mm• Cable, M8/M12 Connector or 12-48VDC Terminal Block 200mA• 2 or 3 Wires• PNP, PNP/NPN, NO, NC, NO/NC – 100Hz Short Housing M12 Plug* CableAvailable Shielded Not Shielded Shielded Not Shielded –Switching Distance (Sn) 1.5mmOperating Voltage 15mm 30mm 15mm 30mm 10-30VDCMax Output Current 200mAOperation LED 10-30VDC 20-250 VAC/DC YellowSwitching Frequency 500HzConnection 200mA 200mA *M8 Plug, CableDimensions Yes Yes 100Hz 25Hz AC; 40Hz Dc Terminal M12 Plug*, Terminal Block Block 40 LED 30 46 60 PG 13.5 40 118 11 65 23 40 40 Ø22.4 15 20 34 M12x1OUTPUT: 40 26PNP NO –––– – IS-88-Q1-03* AS80-50DN3 –NPN NO + NC IS-40-W6-03 IS-40-Y6-03 – – – – –NPN NO + NC Short Housing M12 Plug* IS-40-X6-S2 – – – AS80-50P3 – –PNP NO + NC IS-40-W5-03 IS-40-Y5-03 – – – – –PNP NO + NC Short Housing M12 Plug* IS-40-X5-S2 – – – –2 Wires AC/DC NO – – IS-40-W7-03 IS-40-Y7-03 LIMIT & PRESSURE SWITCHES & SENSORS2 Wires AC/DC NC – – IS-40-W8-03 IS-40-Y8-03 *For M8 plug type replace 03 with S1 e.g. IS-88-Q1-S1 For sensor cable and accessories see pages 329-332 DC SENSOR TESTER For M12 Connector, Cable & Terminal DC Sensors Code Description ST-02 • PNP (sourcing) and NPN (sinking) Testing • M12-5-Pin Plug Input • Terminal Inputs • Two Output LED's • Battery Powered DAT 292

DC 2 WIRE 10-30VDC INDUCTIVE PROXIMITY SWITCHES IP67 DC DC DC Diameter Ø12 Ø18 Ø30 Shielded Non Shielded • Nominal Voltage: 10-30VDC • Max. Output Current: 100mA • Temperature Range: -25 to 70°C • Housing Material: Nickel Plated Brass • Cost Effective Switching Distance 2mm 4mm 5mm 8mm 10mm 15mm Operation LED Yellow Yellow Yellow Switching Frequency 1000Hz 1000Hz View of male 300Hz Cable Length 2m 2m connector 2m Wiring Diagrams M12 BROWN For sensor cable and accessories see pages 329-332 NO Configuration of Contacts BLUE N. contacts BLUE Available 1 2 3 4 NC NO + _ NC _ + BROWN OUTPUT: IS-12-A9-03 IS-12-C9-03 IS-18-A9-03 IS-18-C9-03 IS-30-A9-03 IS-30-C9-03 NO-NC programmable Cable IS-12-A9-S2 IS-12-C9-S2 IS-18-A9-S2 IS-18-C9-S2 IS-30-A9-S2 IS-30-C9-S2 NO-NC programmable (M12 connector) SPECIAL DC INDUCTIVE PROXIMITY SWITCHES IP67 Weld Field Immune Metal Face Diameter Ø12 Ø18 Ø12 Ø18 Shielded Non Shielded • Nominal Voltage: 10-30VDC • Max. Output Current: 200mA • Temp. Range: -25 to 70°C • Housing Material: Stainless Steel • Weld field immune is intrinsically safe and used in welding bays.LIMIT & PRESSURE SWITCHES & SENSORS Switching Distance 2mm 4mm 5mm 8mm 2mm 4mm 5mm 8mm Operation LED Present 1000Hz Present 500Hz Present 1000Hz Present 500Hz Switching Frequency 2000Hz 1000Hz 2000Hz 1000Hz Active Face Material ETFE ETFE Stainless Steel Stainless Steel Wiring Diagrams View of quadripole Configuration of Contacts For sensor cable and male connector accessories see M12 N. contacts pages 329-332 Available 1 2 3 4 NO + - no OUTPUT: IS-F12-S1-S2 IS-F12-T1-S2 IS-F18-S1-S2 IS-F18-T1-S2 IS-12-I1-S2 IS-12-L1-S2 IS-18-I1-S2 IS-18-L1-S2 PNP NO M12 Plug293 DAT

24-250VAC/VDC INDUCTIVE PROXIMITY SWITCHES NO OR NC IP67Diameter Ø 12 Ø 18 Ø 30 Shielded Non Shielded• Current output 200mA maxSwitching Distance 2mm 4mm 4mm 8mm 5mm 8mm 8mm 16mm 10mm 16mm 15mm 25mmNominal Voltage 20-250VAC/VDC 20-250VAC/VDCMax Output Current 20-250VAC/VDC 200mA 200mASwitching Frequency 25Hz AC/ 35Hz DC 25Hz AC/ 35Hz DCOperating Temperature 200mA -25°C to 75°C -25°C to 75°CSensing Face PBT PBTHousing 25Hz AC/ 35Hz DC Nickel Plated Brass Nickel Plated BrassConnection Cable 2m, M12 Plug Cable 2m, M12 PlugOperation LED -25°C to 75°C Present PresentWiring Diagram PBT Nickel Plated Brass Cable 2m, M12 Plug Present Dimensions M12x1 M12x1 M12x1 M12x1 M18x1 M18x1 M18x1 M18x1 M30x1,5 M30x1,5 M30x1,5 M30x1,5 60 52 8 26 55 5 43 12 55 40 15 15 15 42 34 60 8 79 LEDx4 64 15 79 26 15 15 68 38 79M12 Connector LED LED LED LED LED LED LEDx4 LEDx4 M12x1 LEDx4 M12x1 LEDx4 15 15 OUTPUT: M12x1 LEDx4 15 15 M12x1 M12x1 M12x1NO Output (Cable Type) IPS12-S2UO60*-A2P IPS12-N4UO60*-A2P IPS18-S5UO55**-A2P IPS18-N8UO55**-A2P IPS30-S10UO55**-A2P IPS30-N15UO55**-A2PDouble Sensing IPS12-S4UO60*-A2P IPS12-N8UO60*-A2P IPS18-S8UO55**-A2P IPS18-N16UO55**-A2P IPS30-S16UO55**-A2P IPS30-N25UO55**-A2PNC Output (Cable Type) IPS12-S2UC60*-A2P IPS12-N4UC60*-A2P IPS18-S5UC55**-A2P IPS18-N8UC55**-A2P IPS30-S10UC55**-A2P IPS30-N15UC55**-A2PDouble Sensing IPS12-S4UC60*-A2P IPS12-N8UC60*-A2P IPS18-S8UC55**-A2P IPS18-N16UC55**-A2P IPS30-S16UC55**-A2P IPS30-N25UC55**-A2P*For plug type replace 0-A2P with 8-A12 For sensor cable and accessories see pages 329-332**For plug type replace 55-A2P with 79-A12 ANALOG INDUCTIVE PROXIMITY SWITCHES 0-10V 4-20mA IP67Diameter Ø 12 Ø 18 Ø 30 Shielded Non Shielded 0.6-6mm 3.1-10mm 3.1-10mm 7.3-20mm 7.3-20mm 17.6-40mmMeasuring DistanceNominal Voltage 18-30VDC 18-30VDC 18-30VDCLoad ResistorOutput Following Frequency V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm V: > 2 kOhm, A: 400 Ohm LIMIT & PRESSURE SWITCHES & SENSORSOperating TemperatureSensing Face 100Hz 100Hz 100HzHousingConnection 0°C to 70°C 0°C to 70°C 0°C to 70°CWiring Diagram PBT PBT PBT Nickel Plated Brass Nickel Plated Brass Nickel Plated Brass Cable 2m Cable 2m Cable 2m Dimensions OUTPUT:Voltage 0-10V IA12-S6V010-2NP IA12-N10V010-2NP IA18-S10V010-2NP IA18-N20V010-2NP IA30-S20V010-2NP IA30-N40V010-2NP IA12-N10I420-2NP IA18-S10I420-2NP IA18-N20I420-2NP IA30-S20I420-2NP IA30-N40I420-2NPCurrent 4-20mA IA12-S6I420-2NP SCA 294

DC INDUCTIVE PROXIMITY SWITCHES STANDARD & SHORT » Diameter NPN or PNP Ø5 Ø6.5 DC Ø8 Shielded Non Shielded • Nominal Voltage 10-30VDC • 4 Wire programing type • 3 Wire plug and cable type • Standard & Short Housing versions For Sensor Cable & Acces- sories see pages 329-332 Nominal Switching Distance (Sn) 0.8mm 1.5mm 2mm 2mm 200mA Max. Output Current 100mA 200mA Present (Yellow) 1000Hz Operation LED Present Present -20 to 60°C 2m Switching Frequency 2000Hz 1000Hz Nickel plated brass Temperature Limits -25 to 60°C -25 to 70°C *For plug type M12 change 'S1' to 'S2' e.g. IS-08-G3-S2 Cable Length 2m 2m Housing Material Stainless Steel Nickel-plated brass View of male connector M12 Wiring Diagrams *For plug type M8 change '03' to 'S1' e.g. IS-65-A3-S1 4 13 Contacts Numbers OUTPUT: Available 1 3 4 3 wire sensors NPN/PNP BROWN BLUE BLACK M8 Plug Type + __ NO/NC NPN & PNP, (NO & NC) Cable type (4 Wire) – – – Cable Type – – NPN & PNP, (NO & NC) M12 connector (4 Wire) – IS-65-A1-03* IS-65-C1-03* IS-65-A2-03* IS-65-C2-03* PNP NO output (3 Wire) IS-05-A1-03* IS-65-A3-03* IS-65-C3-03* IS-08-G1-03 IS-08-G1-S1* IS-65-A4-03* IS-65-C4-03* IS-08-G2-03 IS-08-G2-S1* PNP NC output (3 Wire) – IS-08-G3-03 IS-08-G3-S1* IS-08-G4-03 IS-08-G4-S1* NPN NO output (3 Wire) IS-05-A3-03* NPN NC output (3 Wire) – NAMUR INDUCTIVE PROXIMITY SWITCHES IP67 Diameter DC DC DC DC Ø30 Ø8 Ø12 Ø18 Shielded Non ShieldedLIMIT & PRESSURE SWITCHES & SENSORS Switching Distance (± 20%) 1mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm Nominal Voltage (Load Resistance 1K) 7.7-9VDC 7.7-9VDC 7.7-9VDC 7.7-9VDC Supply Voltage 5-24VDC 5-24VDC 5-24VDC 5-24VDC Switching Frequency 2000Hz 2000Hz 1000Hz 500Hz Cable IS-08-A20-03 IS-08-C20-03 IS-12-A20-03 IS-12-C20-03 IS-18-A20-03 IS-18-C20-03 IS-30-A20-03 IS-30-C20-03 Plug-in (M12 Connector) IS-08-A20-S2 IS-08-C20-S2 IS-12-A20-S2 IS-12-C20-S2 IS-18-A20-S2 IS-18-C20-S2 IS-30-A20-S2 IS-30-C20-S2 NPN NO-NC - - - - - - - - PNP NO-NC - - - - - - - - Relay Output: 18 to 240VAC/DC - - - - - - - - Wiring Diagrams View of male connector M12 Configuration of Contacts N. contacts Available 1 2 3 4 NAMUR + _ For Sensor Cable & Accessories Note: Can only be used with AC/DC see pages 329-332 NAMUR Relay \"NSI\" or instruments with NAMUR inputs295 DAT

» HOUSING 3 WIRE OR 4 WIRE PROGRAMMABLE OUTPUT IP67DC Ø12 DC Ø18 DC Ø302mm 4mm 4mm 8mm 5mm 8mm 8mm 14mm 10mm 15mm 15mm 20mm200mA 200mA 200mAPresent (Yellow) Present (Yellow) Present (Yellow)1000Hz 1000Hz 300Hz-25 to 70°C -25 to 70°C -25 to 70°C2m 2m 2mNickel plated brass Nickel plated brass Nickel plated brass *For plug type M12 change '03' to 'S2' e.g. IS-12-A3-S2 Housing Lengths (mm) Standard Short Connector Cable Connector Cable SH NS SH NS SH NS SH NS M12 68 72 58 64 48 54 42 48 M18 73 82 70 78 56 65 47 56 4 wire sensors programmable output 3 wire sensors M30 74 85 70 82 56 68 49 56IS-12-A0-03 IS-12-E0-03 IS-12-C0-03 IS-12-F0-03 IS-18-A0-03 IS-18-E0-03 IS-18-C0-03 IS-18-F0-03 IS-30-A0-03 IS-30-E0-03 IS-30-C0-03 IS-30-F0-03IS-12-A0-S2 IS-12-E0-S2 IS-12-C0-S2 IS-12-F0-S2 IS-18-A0-S2 IS-18-E0-S2 IS-18-C0-S2 IS-18-F0-S2 IS-30-A0-S2 IS-30-E0-S2 IS-30-C0-S2 IS-30-F0-S2IS-12-A1-03* IS-12-G1-03* IS-12-C1-03* IS-12-H1-03* IS-18-A1-03* IS-18-G1-03* IS-18-C1-03* IS-18-H1-03* IS-30-A1-03* IS-30-G1-03* IS-30-C1-03* IS-30-H1-03* IS-12-A2-03* IS-12-G2-03* IS-12-C2-03* IS-12-H2-03* IS-18-A2-03* IS-18-G2-03* IS-18-C2-03*IS-18-H2-03* IS-30-A2-03* IS-30-G2-03* IS-30-C2-03* IS-30-H2-03*IS-12-A3-03* IS-12-G3-03* IS-12-C3-03* IS-12-H3-03* IS-18-A3-03* IS-18-G3-03* IS-18-C3-03* IS-18-H3-03* IS-30-A3-03* IS-30-G3-03* IS-30-C3-03* IS-30-H3-03*IS-12-A4-03* IS-12-G4-03* IS-12-C4-03* IS-12-H4-03* IS-18-A4-03* IS-18-G4-03* IS-18-C4-03* IS-18-H4-03* IS-30-A4-03* IS-30-G4-03* IS-30-C4-03* IS-30-H4-03*CAPACITIVE SENSORS 12-30VDC NPN OR PNP 18-240VAC/DC RELAY OUTPUT IP67DC DC AC AC Ø18 Ø30 Ø30 Ø18/*Ø30 Available1-5mm 1-10mm 1-20mm 1-25mm 1-20mm 2-30mm 2-8mm *2-20mm 2-15mm *2-30mm LIMIT & PRESSURE SWITCHES & SENSORS- -12-30VDC (-15/+10%) 12-30VDC (-15/+10%) --10Hz 10Hz- - - - 18-230VAC/DC (-15/+10%) 50Hz 20-250VAC/DC (-15/+10%) 50Hz- - - -CS-07 CS-13 CS-09 CS-15 10Hz 25Hz (Ø18) 25Hz (Ø18)CS-08 CS-14 CS-10 CS-16- - - - - - N/O CCM1-1808A-A3L2 CCM2-1815A-A3L2 - - N/C CCM1-1808A-B3L2 CCM2-1815A-B3L2Ex Class II - - *2-20mm(Ø30) *2-30mm(Ø30) - - N/O CCM1-3020A-A3L2 CCM2-3020A-A3L2 CS-31 *CS-31TE CS-32 *CS-32TE N/C CCM1-3020A-B3L2 CCM2-3020A-B3L2 *with 1s-5m time activating delay. Relay Output DAT 296

M12 DC PHOTOELECTRIC SENSOR PLASTIC AND METAL PNP/NPN IP67 Type DC M12 Ø12 Diffuse Proximity Retro-Reflective Through Beam M12 SERIES Non-Polarized Polarized • Nominal Voltage 10-30VDC • Output: NPN or PNP • Output Current: 150mA • Housing Material: PBT (plastic v) Nickel Plated Brass ( metal v) • Temperature Range: -25 to 70°C Sensing Distance 200mm 2m 1m 5.2m DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30Vdc Emission Infrared LED 880nm Infrared LED 880nm Red light 660nm Infrared LED 880nm Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer Switching Frequency 1kHz 1kHz 1kHz 25Hz Operation Mode Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Light-ON / Dark-ON selectable^ Wiring Diagrams PNP Output Type Emitter of Thru-beam Mode NPN Output Type ^Light/Dark changeover by the A. load or B. load ^Light/Dark changeover by the A. load or B. load OUTPUT: Metal Housing Version Plug Type NPN Cable Version M12P*-D0200N-CX9C4U2** M12P*-L2000N-CX9C4U2** M12P*-L1000N-CX6C4U2**-PF M12P*-T5200N-CX9C4U2** PNP Cable Version Emitter Cable Version M12P*-D0200P-CX9C4U2** M12P*-L2000P-CX9C4U2** M12P*-L1000P-CX6C4U2**-PF M12P*-T5200P-CX9C4U2** Emitter M12 Plug Version - - - M12P*-T5200D-EX9C3L2 - - - M12P*-T5200D-EX9Q4LE *For metal type replace P with B e.g. M12B-D0200N-CX9C4U2 **For plug type replace C4U2 with Q4UE e.g. M12P-D002N-CX9Q4UE For Sensor Cables and accessories see pages 329-332 MINI BEAM PHOTOELECTRIC SENSOR PNP AND NPN CONFIGURABLE IP67 Type DC Diffuse Proximity Retro-Reflective Through Beam MP SERIES Medium Distance Fixed Focus Non-Polarized Polarized • Nominal Voltage 10-30VDC • Output: NPN or PNP Configurable • Output Current: 150mA • Housing Material: Reinforced Thermoplastic Polyester • Temperature Range: -25 to 70°CLIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 380mm 16mm 0.1-5m 2m 0-3m DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDC Emission Infrared LED 880nm Infrared LED 880nm Red light 650nm Red light 650nm Infrared LED 880nm Setting sensitivity trimmer sensitivity trimmer sensitivity trimmer sensitivity trimmer Switching Frequency** 1kHz 1kHz 1kHz 1kHz 25Hz Operation Mode Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON Light-ON / Dark-ON select switch select switch select switch select switch select switch Pico Style Pigtail Plug Type Wiring Diagrams OUTPUT: NPN/PNP Emitter of Thru-beam Mode NPN & PNP Cable Version NPN & PNP M8 Pigtail Pico** MP-D0380D-CX9C4U2 MP-C0016D-CX9C4U2 MP-L5000D-CX6C4U2 MP-L2000D-CX6C4U2-PF MP-T3000*D-CX9C4U2 Emitter Cable Version Emitter M8 Pigtail Pico** MP-D0380D-CX9P4UP MP-C0016D-CX9P4UP MP-L5000D-CX6P4UP MP-L2000D-CX6P4UP-PF MP-T3000*D-CX9P4UP 297 - - - - MP-T3000*D-EX9C3L2 - - - - MP-T3000*D-EX9P4LP *For units with 30m sensing distance change 3000 to 030M e.g. MP-T030MD-CX9C4U2 For sensor cable and accesssories see pages 329-332. **High Speed Type available on request SCA

AC PHOTOELECTRIC SENSORS 3 WIRE DARK/LIGHT MODE IP67Type AC M18 Ø18 Fixed Focus Short Distance Medium Distance Retro-Reflective Through Beam Through Beam Proximity Diffuse Proximity Diffuse Proximity Receiver EmitterS5 SERIES• Nominal Voltage 15-264VAC• Output: SCR + Bidge Rectifier• Max. Output Current: 100mA• Temperature Range: -25 to 55°C• Housing Material: ABS• Switching Frequency: 25HzSensing Distance 15mm 80mm 300mm 0.1-4m (R2 Reflector*) 8m 8mAC Supply Voltage 15-264VACEmission 15-264VAC 15-264VAC 15-264VAC 15-264VAC 15-264VAC Infrared LED 880nmSetting –Output LED Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm RedDimensions – – Sensitivity trimmer Sensitivity trimmer Sensitivity trimmerOUTPUT:Dark Mode. Cable Version Red Red Red Red RedLight Mode. Cable Version AC AXIAL VERSIONWiring Diagrams 23.5 Models S5For sensor cable and Output LED With trimmer Without Trimmeraccessories see pages 329-332 Power on LED 22 3.2 X1 52 42 L 75 65 LIMIT & PRESSURE SWITCHES & SENSORS S5-1-D15-10 S5-1-C8-10 S5-1-C30-10 S5-1-A2-10 S5-1-F8-10 S5-1-G8-00 S5-1-D15-20 S5-1-C8-20 S5-1-C30-20 S5-1-A2-20 S5-1-F8-20 Light = NO. Dark = NC Receiver For Radial Optics 90° Sensing use DEV90 Accessory Emitter S5 SERIES AXIAL 10-30VDC 4 WIRE CONFIGURABLE DARK/LIGHT MODE IP67Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through BeamS5 SERIES Short Medium Long Fixed Focus Non- Polarized Receiver Emitter• Nominal Voltage 10-30VDC Distance• Output: NPN or PNP Configurable Distance Distance Polarized• Max. Output Current: ≤150mA• Temp. Range: -25 to 55°C• Housing Material: ABSSensing Distance 100mm 350mm 600mm 15mm 4m(R2 Reflector)* 3m(R2 Reflector)* 12m 12mSupply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDCEmission Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Red LED 880nmSetting Sensitivity – – Sensitivity Sensitivity – – Sensitivity trimmer trimmer trimmer trimmerOutput LED Red OUTPUT Red OUTPUT Red OUTPUT Red OUTPUT Red Power Green STABILITY Green STABILITY Green STABILITY Green STABILITYSwitching Frequency 500Hz 500Hz 500Hz 250HzDimensionsFor sensor cable andaccessories see pages 329-332.For Radial Optics 90° Sensing useDEV90 AccessoryOUTPUT:NPN & PNP Dark/Light.Cable Version S5-5-C10-30 S5-5-C35-30 S5-5-C60-30 S5-5-D15-30 S5-5-A4-30 S5-5-B3-30 S5-5-F12-30 S5-5-G12-00 S5-5-C60-32 S5-5-D15-32 S5-5-A4-32 S5-5-B3-32 S5-5-F12-32 S5-5-G12-02NPN & PNP Dark/Light. M12 plug* S5-5-C10-32 S5-5-C35-32Plug Type Wiring Diagrams DAT 298

DC PHOTOELECTRIC SENSORS SHORT HOUSING PLASTIC » Type DC M18 Ø18 Diffuse Proximity Medium Distance Long Distance Fixed Focus Short Distance S15 SERIES • Nominal Voltage 12-30VDC • Output: NPN or PNP • Output Current: ≤100mA • Temperature Range: -25 to 55°C • New stainless steel models • IP67+IP69K on all models • Johnson Diversey certification for detergents • Atex II 3dg certification Sensing Distance 1-10cm 1-35cm 1-100cm 1-5cm DC Supply Voltage 12-30VDC 12-30VDC Emission 12-30VDC 12-30VDC Infrared LED 880nm Red LED 660nm Setting Sensitivity Trimmer* - Output LED Infrared LED 880nm Infrared LED 880nm Yellow Output LED Yellow Output LED Switching Frequency 500 Hz 1Khz Operation Mode – Sensitivity Trimmer* Light/Dark Selectable^ Light/Dark Selectable^ S15-PA-2/3 Yellow Output LED Yellow Output LED S15-PA/NA-5 500 Hz 500 Hz Light/Dark Selectable^ Light/Dark Selectable^ Dimensions S15-PA-2/3-D50 A01/B01/C31/ M01 T01/F01/G01 OUTPUT: L 48.8 53.3 NPN Cable PNP Cable L1 32.85 37.55 NPN M12 Plug PNP M12 Plug S15-PA-2-C00-NK S15-PA-2-C10-NK - S15-PA-2-D50-NK NPN M12 Plug Stainless Steel PNP M12 Plug Stainless Steel S15-PA-2-C00-PK S15-PA-2-C10-PK - S15-PA-2-D50-PK – S15-PA-5-C11-NK S15-PA-5-C31-NK - – S15-PA-5-C11-PK S15-PA-5-C31-PK - – S15-NA-5-C11-NK S15-NA-5-C31-NK - – S15-NA-5-C11-PK S15-NA-5-C31-PK - *Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332 DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67 Type DC M18 Ø18 Diffuse Proximity S50 SERIES Short Distance Medium Distance Long Distance Fixed Focus • Nominal Voltage 10-30VDC 400mm • Output: NPN or PNP 10-30VDC • Contacts: NO and NC Infrared LED 880nm • Output Current: ≤100mA – • Housing Material: PBT - Lens PMMA Sensitivity trimmer • Temperature Range: -25 to 55°C Yellow/Green (stability) ''One For All\" 1kHz • Flat plastic or cylindrical metal housing Dark on NO / light on NC • Versions with Trimmers • Cable or M12 Connection • EN standard NPN or PNP NO-NC configuration Sensing Distance 100mm 700mm 100mm 10-30VDC 10-30VDC DC Supply Voltage 10-30VDC Infrared LED 880nm Red LED 630nm – –LIMIT & PRESSURE SWITCHES & SENSORS Emission Red 630nm Sensitivity trimmer – Yellow/Green (stability) Yellow Minimum Detectable Object – 1kHz 1kHz Dark on NO / Light on NC Dark on NO / light on NC Setting – M12 Connector Output LED Yellow Switching Frequency 1kHz Operation Mode Dark on NO / Light on NC Metal Housing Version Wiring Diagrams Plug Type OUTPUT: NPN NO-NC Cable S50-P**A-2*-C10-NN S50-P**A-2*-C21-NN S50-P**A-2*-C01-NN S50-P**A-2*-D00-NN PNP NO-NC Cable S50-P**A-2*-C10-PP S50-P**A-2*-C21-PP S50-P**A-2*-C01-PP S50-P**A-2*-D00-PP Emitter Cable – – –– *For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN For sensor cable and accessories see pages 329-332 **For metal type replace P with M e.g. S50-MA-5-C10-PK For Radial Optics 90° Sensing use DEV90 Accessory299 DAT

»AND STAINLESS STEEL PNP/NPN IP67 & IP69K ATEX II 3dgRetro-Reflective Polarized Transparents Through Beam EmitterNon-Polarized Background Suppression Receiver0.1-5m (R2 Reflector) 0.1-4m (R2 Reflector) 0.1-8m (R2 Reflector) 40-120mm 0-20m 0-20m12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDC 12-30VDCInfrared LED 880nm Red LED 660nm Red LED 660nm Red LED 660nm - Infrared LED 880nmSensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* Sensitivity Trimmer* -Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED Yellow Output LED500 Hz 500 Hz 500 Hz 500 Hz 250 Hz -Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^ Light/Dark Selectable^Wiring Diagrams M12 Connector ^With Light/Dark input not connectedCable S15...A01/B01/C11/C31/T01/F01/M01 S15...G01 the Proximity models function in theS15...A00/B00/C00/C10/F00/D50 S15...G00 light mode, the retroreflex and through beam models in the Dark mode. The Light mode can be selected connecting the Light/Dark input to +Vdc and the Dark mode connecting it to the 0Vdc.S15-PA-2-A00-NK S15-PA-2-B00-NK - - S15-PA-2-F00-NK S15-PA-2-G00-XGS15-PA-2-A00-PK S15-PA-2-B00-PK - - S15-PA-2-F00-PKS15-PA-5-A01-NK S15-PA-5-B01-NK S15-PA-5-T01-NK S15-PA-5-M01-NK S15-PA-5-F01-NK S15-PA-5-G01-XGS15-PA-5-A01-PK S15-PA-5-B01-PK S15-PA-5-T01-PK S15-PA-5-M01-PK S15-PA-5-F01-PKS15-NA-5-A01-NK S15-NA-5-B01-NK S15-NA-5-T01-NK - S15-NA-5-F01-NK S15-NA-5-G01-XGS15-NA-5-A01-PK S15-NA-5-B01-PK S15-NA-5-T01-PK - S15-NA-5-F01-PK*Sensitivity trimmer on M12 Plug Units Only For sensor cable and accessories see pages 329-332DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN NO-NC IP67Retro-Reflective Contrast Sensor Through BeamNon-Polarized Retroreflex for Transparents Polarized0.1-5m (R2,R5 reflector*) 4m (R2,R5 reflector*) 0.7-1.7m (R2,R5 reflector*) 10mm 0-20m LIMIT & PRESSURE SWITCHES & SENSORS10-30VDC 10-30VDC 10-30VDC 10-30VDC 10-30VDCInfrared LED 880nm Red 660nm Red LED 660nm White LED 400-700nm Infrared LED 880nm– – – 0.5mm –– Sensitivity trimmer Sensitivity trimmer Teach-in push-button Sensitivity trimmerYellow Yellow/Green (stability) Yellow Yellow/Green/Red Error Yellow/Green (stability)1kHz 1kHz 1kHz 5kHz 250kHzDark on NO / light on NC Dark on NO / light on NC Dark on NO / light on NC Dark with EASYtouch™ Dark on NO / light on NCS50-P**A-2*-A00-NN S50-P**A-2*-B01-NN S50-P**A-2*-T01-NN S50-P**A-2*-W03-NN S50-P**A-2*-F01-NN S50-P**A-2*-T01-PP S50-P**A-2*-W03-PP S50-P**A-2*-F01-PPS50-P**A-2*-A00-PP S50-P**A-2*-B01-PP – – S50-P**A-2*-G00-XG–– DAT 300Laser models available on request

DC PHOTOELECTRIC SENSORS PLASTIC AND METAL AXIAL PNP/NPN IP67 Type DC M18 Ø18 Diffuse Proximity Retro-Reflective Through Beam Non-Polarized Polarized S51 SERIES Short Distance Long Distance Receiver Emitter • Nominal Voltage 10-30VDC • Output: NO, NPN or PNP • Output Current: ≤100mA • Housing Material: PBT (plastic v) Nickel Plated Brass (metal v) • Temperature Range: -25 to 55°C • Flat plastic or cylindrical metal housing • Cable or M12 connection NPN or PNP output •Standard 3 wire connection configuration Sensing Distance 100mm 400mm 0.1-4m (R5 Reflector) 0.1-3m (R5 Reflector) 20m DC Supply Voltage Emission 10-30VDC 10-30VDC 10-30VDC Setting Output LED Infrared LED 880nm Infrared LED 880nm Red LED 650nm Infrared LED 880nm Switching Frequency Operation Mode – Sensitivity trimmer – Sensitivity trimmer – –– – Yellow Output LED 500Hz 500Hz 120Hz – Dark/Light selectable^ Dark/Light selectable^ Dark/Light selectable^ ^With Light/Dark input not connected the Proximity models function in the light mode, the retroreflex and through beam models in the Dark mode. The Light mode can be selected connecting the Light/Dark input to +Vdc and the Dark mode connecting it to the 0Vdc Metal Housing Version Wiring Diagrams M12 Connector OUTPUT: Plug Type NPN Cable PNP Cable S51-P**A-2*-C10-NK S51-P**A-2*-C01-NK S51-P**A-2*-A00-NK S51-P**A-2*-B01-NK S51-P**A-2*-F00-NK S51-P**A-2*-G00-XG S51-P**A-2*-C10-PK S51-P**A-2*-C01-PK S51-P**A-2*-A00-PK S51-P**A-2*-B01-PK S51-P**A-2*-F00-PK *For plug type replace 2 with 5 e.g. S51-PA-5-B01-PK For sensor cable and accessories see pages 329-332 **For metal type replace P with M e.g. S51-MA-5-B01-PK For Radical Optics, replace A with R. E.g. S51-PR-5-B01-PK MINIATURE PHOTOELECTRIC SENSOR BASIC LINE NPN or PNP NO-NC IP66 Type DC Diffuse Proximity Retro-Reflective Through Beam Through Beam S41 SERIES Emitter Receiver Polarized Transparents • Nominal Voltage 10-30VDC • Output: NPN or PNP NO-NC • Output Current: 100mA max. • Housing Material: PMMA Plastic • Temperature Range: -25 to 55°C • Models with trimmer setting • NPN or PNP output •Double NO-NC Sensing Distance 0.2-350mm 0.1-2.5m (R2 Reflector) 0.1-0.7m (R2 Reflector) 0.1-6m 0.1-6m Supply Voltage 10-30VDC 10-30VDCLIMIT & PRESSURE SWITCHES & SENSORS Emission Infrared LED 880nm 10-30VDC 10-30VDC 10-30VDC Infrared LED 880nm Setting Sensitivity trimmer – Output LED Red/Green Red LED 660nm Red LED 660nm Infrared LED 880nm Red/Green Switching Frequency 500Hz 500Hz Operation Mode Dark or Light Sensitivity trimmer Sensitivity trimmer – Dark or Light Wiring Diagrams 32H x 12W x 20D Yellow/Green Red/Green Red/Green 500Hz 500Hz 500Hz Dark or Light Dark or Light Dark or Light Plug Type M8 CONNECTOR M8 CONNECTOR M8 CONNECTOR OUTPUT: S41-2*-C-P S41-2*-B-P S41-2*-T-P S41-2*-G S41-2*-F-P PNP NO-NC Cable NPN NO-NC Cable S41-2*-C-N S41-2*-B-N S41-2-*T-N S41-2*-G S41-2*-F-N 301 *For plug type replace 2 with 5 e.g. S41-5-C-P For sensor cable and accessories see pages 329-332 *For plug and cable use part number CS-B1-02-G-05/03 DAT

PHOTOELECTRIC SENSORS MICROPROCESSOR-BASED TEACH-IN NPN/PNP IP67Type DC Diffuse Polarized Retro-Reflective Background Proximity Transparents SuppressionS40 SERIES• Nominal Voltage 10-30VDC• Output: NPN or PNP• Output Current: 100mA max.• Housing Material: ABS• Temperature Range: -20 to 60°C• EASYtouch™ microprocessor teach in and Remote setting• Cable or M8 connection• NPN or PNPSensing Distance 0.5-300mm 0.1-2.5m (R2 Reflector) 0.1-7m (R2 Reflector) 15-100mmDC Supply Voltage 10-30VDC 10-30VDC 10-30VDCEmission Red LED 660nm Red LED 660nm Red LED 660nmSetting Teach-in button Teach-in push-button Teach-in buttonOutput LED Yellow/Green Yellow/Green Yellow/GreenSwitching Frequency 4kHz 1kHz 1kHzOperation Mode Dark/light prog. Dark/light programmable Dark/light prog.M8 Connector Wiring Diagrams NPN output PNP output S40-x-G Plug TypeOUTPUT: S40-PR-2*-C03-PH S40-PR-2*-B03-PH S40-PR-2*-T03-PH S40-PR-2*-M03-PHPNP CableNPN Cable S40-PR-2*-C03-NH S40-PR-2*-B03-NH S40-PR-2*-T03-NH S40-PR-2*-M03-NH *For plug type replace 2 with 5 e.g. S40-PR-5-A03-PH For sensor cable and accessories see pages 329-332 *For plug and cable use part number CS-B1-02-G-05/03 Laser models available on requestDC MINIATURE PHOTOELECTRIC SENSORS NPN/PNP DARK/LIGHT MODE IP67Type DC Diffuse Proximity Polarized Narrow Beam Proximity Through Beam Set Retro-ReflectiveS3Z SERIES Ø 1mm• Nominal Voltage 10-30VDC• Output: NPN or PNP• Output Current: ≤100mA• Housing Material: PC/PBT• Temperature Range: -25 to 55°CSensing Distance 0-700mm 0.05-4m (R5 Reflector)* 150mm 15m LIMIT & PRESSURE SWITCHES & SENSORSDC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDCEmission Infrared LED 870nm Red LED 665nm Red LED 665nm Infrared LED 870nmSetting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmerOutput LED Yellow/Green (stability) Yellow/Green (stability) Yellow/Green (stability) –Switching Frequency 500Hz 500Hz 500Hz 500HzOperation Mode Dark or light Dark or light Dark or light Dark or light Wiring Diagrams M8 ConnectorOUTPUT: S3Z-PR-2*-C11-PL S3Z-PR-2*-B01-PL S3Z-PR-2*-C01-PL S3Z-PR-2*-FG01-PLPNP Light. Cable VersionPNP Dark. Cable Version S3Z-PR-2*-C11-PD S3Z-PR-2*-B01-PD S3Z-PR-2*-C01-PD S3Z-PR-2*-FG01-PDNPN Light. Cable VersionNPN Dark. Cable Version S3Z-PR-2*-C11-NL S3Z-PR-2*-B01-NL S3Z-PR-2*-C01-NL S3Z-PR-2*-FG01-NLLight = NO. Dark = N.C S3Z-PR-2*-C11-ND S3Z-PR-2*-B01-ND S3Z-PR-2*-C01-ND S3Z-PR-2*-FG01-ND *For plug type replace 2 with 5 e.g. S3Z-PR-5-C01-PL For sensor cable and accessories see pages 329-332 *For plug and cable use part number CS-B1-02-G-05/03 Laser models available on request DAT 302

ECONOMY DC MINIATURE SENSOR PNP/NPN IP67 Type DC Diffuse Proximity Long Distance Fixed Focus S100 SERIES Medium Distance • Nominal Voltage: 10-30VDC • Output: NPN or PNP • Output Current: 100mA • Temperature Range: -25 to 55°C • Housing Material: ABS (housing) / PMMA (indicators cover) • Cost Effective Sensing Distance 300mm 500mm 70mm DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC Emission Red LED 632nm Red LED 632nm Red LED 632nm Switching Frequency 500 Hz 500 Hz 500 Hz Operation Mode Dark/Light input Dark/Light input Dark/Light input Plug Type Dimensions Anti tampering sensor Two threaded front mounting holes OUTPUT: Two slotted rear mounting holes PNP Cable S100-PR-2*-C00-PK S100-PR-2*-C10-PK S100-PR-2*-D00-PK NPN Cable S100-PR-2*-C00-NK S100-PR-2*-C10-NK S100-PR-2*-D00-NK Type DC *For plug type replace 2 with 5 e.g. S50-PA-5-B01-NN Through Beam S100 SERIES For sensor cable and accessories see pages 329-332 • Nominal Voltage: 10-30VDC Retro-Reflective Background • Output: NPN or PNP Suppression • Output Current: 100mA Non-Polarized Polarized • Temperature Range: -25 to 55°C • Housing Material: ABS (housing) / PMMA (indicators cover) • Cost AffectiveLIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 8m 6m 30-100mm 12m DC Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC Emission Infrared LED 860nm Red LED 632nm Red LED 632nm Infrared LED 860nm Switching Frequency 500 Hz 500 Hz 500 Hz 250Hz Operation Mode Dark/Light input Dark/Light input External Teach-In Dark/Light input Wiring Diagrams For plug and cable, use code CS-BI-02-G-05/3 PNP Cable S100-PR-2*-A00-PK S100-PR-2*-B10-PK S100-PR-2*-M00-PH S100-PR-2*-FG00-PK S100-PR-2*-B10-NK S100-PR-2*-M00-NH S100-PR-2*-FG00-NK NPN Cable S100-PR-2*-A00-NK DAT303

DC ADVANCED PHOTOELECTRIC SENSORS NPN/PNP IP67 ATEXType DC Diffuse Proximity Retro-Reflective Through BeamS8 SERIES Polarized Transparents• Nominal Voltage 12-30VDC 500mm 5m (R2 Reflector) 50-800mm** 25m• Output: NPN or PNP NO 12-30VDC• Output Current: ≤100mA max. Red LED 660nm 12-30VDC 12-30VDC• Housing Material: ABS Mono turn sensitivity adj. trimmer• Temperature Range: -10 to 55°C Yellow/Green Red LED 660nm Red LED 660nm• Excellent performances within 500us small dimensions (14x42x25mm) 1kHz Mono turn sensitivity adj. trimmer Set push button (T53) Mono turn sensitivity adj. trimmer• Compact Dimensions Dark/Light selectable• Very High Resolution Yellow/Green Yellow/Green• High performance for most M8 Connector challenging applications 500us 250us 500usSensing Distance 1kHz 2kHz 1kHzDC Supply Voltage Dark/Light selectable Dark/Light selectableEmission M8 Connector - B01/T51 Version - T53 Version M8 Connector - F01 VersionSettingOutput LEDResponse TimeSwitching FrequencyOperation ModeWiring Diagrams - G00 VersionOUTPUT: S8-PR-5-C01-PP S8-PR-5-B01-PP S8-PR-5-T51**-PP S8-PR-5-F01-PPPNP M8 Plug*NPN M8 Plug* S8-PR-5-C01-NN S8-PR-5-B01-NN S8-PR-5-T51**-NN S8-PR-5-F01-NNThrough Beam Emitter - - - S8-PR-5-G00-XG *For M8 plug and cable see pages 329-332. Stainless Steel models available on request **For retro-reflective for transparent units with 2000mm sensing distance replace 1 with 3 e.g. S8-PR-5-T53-PP *For plug and cable use part number CS-B1-02-G-05/03Type DC Clear and Shiny Detection Background Suppression ContrastS8 SERIES• Nominal Voltage 12-30VDC• Excellent performances within small dimensions• Compact Dimensions• Very High ResolutionSensing Distance 100-300mm 50-150mm 50-300mm 20-200mm 9mmDC Supply Voltage 12-30VDCEmission 12-30VDC 12-30VDC Blue, Green, RedSetting Teach-in push-buttonOutput LED Red LED 660nm Red Laser Red LED 660nm Red Laser Yellow/Green LIMIT & PRESSURE SWITCHES & SENSORSResponse Time 50usSwitching Frequency 8-turn distance adj. trimmer, Teach 8-turn distance adj. trimmer 10kHzOperation Mode Dark/Light selectableWiring Diagrams Yellow/Green Yellow/GreenOUTPUT: 1ms 1ms 100usPNP M8 Plug*NPN M8 Plug* 500Hz 500Hz 5kHz Remote Dark/Light selectable Dark/Light selectable M8 Connector M8 Connector - PR Version S8-PR-5-M53-PP S8-PH-5-M53-PP S8-PR-5-M01-PP M8 Connector - - - S8-PR-5-M01-NN PH Version *For M8 plug and cable see pages 329-332 S8-PH-5-M01-PP S8-PR-5-W03-PP S8-PH-5-M01-NN S8-PR-5-W03-NN All the safety electrical and mechanical regulations and laws have to be respected during sensor functioning. The sensor has to be protected against mechanical damages. Place the given labels in a visible position close to the laser emission. • Do not look directly into the laser beam! • Do not point the laser beam towards people! • These sensors are not to be used for safety applications! DAT 304

THE MOST COMPLETE UNIVERSAL SENSOR IN A COMPACT 50X50MM HOUSING IP67 Type DC Diffuse Proximity Retro-Reflective Through Beam S62 SERIES C01 C11 Non-Polarised Polarised Receiver Emitter • New better modern look 50x50 housing • Better performance • Retroreflective up to 13m • VDC and VAC Models Sensing Distance 0-900mm 0-200cm 0.1-13m (R2,R5 reflector) 0.1-8m (R2,R5 reflector) 0-25m 0-25m Supply Voltage Emission 10-30VDC / 24-240VAC/24-60VDC** Setting Output LED RED 640nm Red 640nm Output Mono-turn sensitivity adjustment trimmer. Mono-turn light/dark trimmer (S62-RX/PN) Output Current Saturation Voltage OUTPUT LED (yellow) / STABILITY LED (green) POWER ON LED (green) Response Time Switching Frequency NPN/PNP (S62-PN)dc vers. NPN or PNP NO/NC Test + Test - Mechanical Protection (S62-PP/NN)dc vers. Relay SPDT 250VAC/30VDC (S62-RX) Housing Material Operating Temperature S62-PA-2/5, S62-M version: ≤100mA (overload and overvoltage protection), S62-PA-1-RX version: 2A Max (resist load) Dimensions ≤2v S62-PA-2/5 VDC vers 500us max, 25ms (Relay version) 500us max, 25ms (Relay version) 1ms, 25ms (Relay version) 1kHz, 20Hz (Relay version) 2kHz, 20Hz (Relay version) 50kHz, 20Hz IP67 IP67 IP67 ABS ABS ABS -10 to 55C° -10 to 55C° -10 to 55C° OUTPUT: S62-PA-2*-C01-NN S62-PA-2*-C11-NN - S62-PA-5-B01-NN S62-PA-2*-F01-NN NPN NO-NC Cable PNP NO-NC Cable S62-PA-2*-C01-PP S62-PA-2*-C11-PP - S62-PA-2*-B01-PP S62-PA-2*-F01-PP S62-PA-2*-G00-XG NPN/PNP Cable Relay Cable** S62-PA-2*-C01-PN S62-PA-2*-C11-PN S62-PA-2*-A01-PN S62-PA-2*-B01-PN S62-PA-2*-F01-PN S62-PA-1-C01-RX S62-PA-1-C11-RX S62-PA-1-A01-RX S62-PA-1-B01-RX S62-PA-1-F01-RX S62-PA-1-G00-XX Wiring DiagramsLIMIT & PRESSURE SWITCHES & SENSORS *For plug type replace 2 wih 5 e.g. S62-PA-5-C01-NN Laser models available on request For sensor cable and accessories see pages 329-332 DC Models AC Models** S62-PA-2/5-PN S62-PA-1-A/B/C/F S62-PA-1-G S62-PA-2/5-PP/NN S62-PA-2/5-G S62-PA-5...PP/NN (M12 connector)305 DAT

BACKGROUND SUPPRESSION 50X50 COMPACT PNP/NPN IP67Type DC Background SuppressionS62 SERIES• Nominal Voltage 10-30VDC• Units with time adjustment trimmer• Background suppression from 3cm-2mSensing Distance 30-300mm 60-600mm 60-1200mm 200-2000mmDC Supply VoltageEmission 10-30VDC 10-30VDC 10-30VDC 10-30VDCSettingOutput LED RED 660nm Infrared (880nm)OutputOutput Current Muliti Turn distance adjustment trimmer / Timer adjustment trimmer (S62-M05/M15/M25/M35). Dark/light selection mono turn trimmer (S62-M01/M11-PN)Saturation VoltageResponse Time OUTPUT LED (yellow) / STABILITY LED (green) (S62-M0/M1) POWER ON LED (green) (S62-M2/M3)Switching FrequencyMechanical Protection NPN or PNP NO/NC (S62-PP/NN)Housing MaterialOperating Temperature 100mA (overload and voltage protection)Dimensions ≤2v ≤2v ≤2v ≤2v 500us (S62-M0/M1), 1ms (S62-M2) 1,5ms(S62-M3) 1kHz (S62-M0/M1), 500Hz (S62-M2), 330Hz (S62-M3) IP67 IP67 IP67 IP67 ABS ABS ABS ABS -10 to 55C° -10 to 55C° -10 to 55C° -10 to 55C°OUTPUT: S62-PA-2-M01-PP S62-PA-2-M11-PP S62-PA-2-M21-PP S62-PA-2-M31-PPPNP NO-NC CableNPN NO-NC M12 Plug S62-PA-5-M01*-NN S62-PA-5-M11*-NN S62-PA-5-M21*-NN S62-PA-5-M31*-NNPNP NO-NC M12 Plug S62-PA-5-M01*-PP S62-PA-5-M11*-PP S62-PA-5-M21*-PP S62-PA-5-M31*-PPWiring Diagrams * For units with timer adjustment trimmer change 1 to 5 e.g. S62-PA-5-M01-NN to S62-PA-5-M05-NN For sensor cable and accessories see pages 329-332 Laser models available on request S62-PA-2/5...PN S62-PA-2...PP/PN S62-PA-5...PP/PN (M12 connector)Detection Diagrams LIMIT & PRESSURE SWITCHES & SENSORS DAT 306

MAXI SENSOR FOR CRITICAL APPLICATIONS VAC/VDC IP67 Type AC/DC Diffuse Proximity Polarized Background Through Beam S300-PR SERIES Retro-Reflective Suppresion Receiver Emitter • Excellent Optical Performances • Heavy duty industrial plastic housing • Distance trimmer clutch for mechanical background suppression models • Units with defogging functions Sensing Distance 5m 22m 2.5m 60m Supply Voltage Emission 24-240VAC / 12-240VDC Setting Infrared LED 940nm Infrared LED 880nm Infrared LED 880nm Infrared LED 880nm Output LED Mono-turn Mono-turn Multi-turn Mono-turn Sensitivity Trimmer Output Sensitivity Trimmer Sensitivity Trimmer Adjustment Screw Output current Saturation Voltage Output LED (Yellow) Stability LED (GREEN) Output Yellow/ Power On LED Green Response Time Stability Green Switching Frequency Mechanical Protection NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30VDC* Housing Material 100mA (Resistive Load). 3A (Resistive Load)* Connections <2.4V Max NPN & PNP only Operating Temperature 20ms (AC), 1ms (S300-C, S300-B, S300-F/G) (DC) 2ms (S300-M) (DC) 25Hz (AC), 500Hz (S300-B, S300-C, S300-F/G) (DC), 250Hz (S300-M) (DC) IP67 PBT (30% Fibre-reinforced Glass) Terminal Block (Recommended Cable Diameter 8mm – 10mm) (AC), 4-Pin M12 Plug (DC) -40º to 55ºC Dimensions M12 Connector Version OUTPUT: Relay NO/NC ADJ, No Timer S300-PR-1-C01-RX S300-PR-1-B01-RX S300-PR-1-M01-RX S300-PR-1-F01-RX S300-PR-1-G00-EX***† Relay NO/NC ADJ, Timer S300-PR-1-C06-RX*** S300-PR-1-B06-RX*** S300-PR-1-M06-RX*** S300-PR-1-F06-RX*** NPN & PNP M12 Plug ADJ, No Timer S300-PR-5-C01-OC S300-PR-5-B01-OC S300-PR-5-M01-OC S300-PR-5-F01-OC NPN & PNP M12 Plug ADJ, Timer S300-PR-5-C06-OC S300-PR-5-B06-OC S300-PR-5-G00-EX***† S300-PR-5-M06-OC S300-PR-5-F06-OC *24-240VAC/12-240VDC AC voltage untis only. ***For defogging functions, add -M to part number. †No ADJ, No Timer, No Outputs For sensor cable and accessories see pages 329-332LIMIT & PRESSURE SWITCHES & SENSORS Wiring Diagrams M12 Connector (only DC models) Connections G Connections B, C, M , F M12 Connector (only DC models) Timing Functions Indicators Four selectable timing functions: one shot, ON DAT delay, OFF delay, ON/OFF delay and normal mode. Trimmer adjustment of the functions is available. The timing functions can be particularly useful in applications where the output signal pulse has to be modified. 307

ADVANCED COST EFFECTIVE MAXI SENSORS VAC/VDC IP67Type AC/DC Diffuse Proximity Retro-Reflective Background Through BeamS300-PA SERIES Non-Polarized Polarized Suppresion Receiver Emitter• Excellent cost/performance ratio• Terminal block for both VDC and VAC/VDC free voltage versions• Sturdy industrial plastic housing IP67Sensing Distance 5-200cm 01.-15m 0.1-10m 20-200cm 0-50mSupply VoltageEmission 12-30VDC or 24-240VAC / 12-60VDC Infrared LED 880nmSetting Infrared LED 940nm Infrared LED 880nm Red LED 660nm Infrared LED 880nmOutput LED 7-Turns adjustment screw. Mono-turn Sensitivity TrimmerOutputOutput Current Mono-turn Sensitivity Trimmer. Dark/Light Dip Switch mode On Dark/Light Dip Switch. Dip Dark/Light Dip Switch.Saturation Voltage delay/Off delay/Single pulse (One-Shot)(S300-X06 version only)Response Time Switch mode On delay/Off Dip Switch mode OnSwitching Frequency delay/Off delay/On-OffMechanical Protection delay/On-Off delay/Single delay/Single pulseHousing Material pulse (One-Shot (One-Shot)(S300-X06ConnectionsOperating Temperature (S300-X06 version only) version only)Dimensions OUTPUT LED (Yellow) / STABILITY LED (Green) / POWER ON LED (Green)(S300-G version) NPN & PNP open collector. Relay SPDT electromagnetic relay 250VAC, 30 VDC* 100mA (resistive load). 3A (resistive load)* <2.4V Max NPN & PNP only 1ms (DC) 25ms (AC) 2ms (S300-G version) 500Hz (DC) 20Hz (AC) 250Hz (S300-G version) IP67 PBT 30% fibre-reinforced glass Terminal Block (recommended cable diameter 8-10mm) -20 to 55°C 100,4 96OUTPUT: 27 40 50 5589.7S300-PA-1-B01-RX S300-PA-1-M01-RX S300-PA-1-F01-RX S300-PA-1-G00-EX**Relay NO/NC ADJ, No Timer 67.5 S300-PA-1-B06-RX S300-PA-1-M06-RX S300-PA-1-F06-RXRelay NO/NC ADJ, Timer S300-PA-1-C01-RX S300-PA-1-A01-RXNPN & PNP ADJ, No Timer S300-PA-1-C06-RX S300-PA-1-A06-RX LIMIT & PRESSURE SWITCHES & SENSORSNPN & PNP ADJ, Timer S300-PA-2-C01-OC S300-PA-2-A01-OC S300-PA-2-B01-OC S300-PA-2-M01-OC S300-PA-2-F01-OCWiring Diagrams S300-PA-2-C06-OC S300-PA-2-A06-OC S300-PA-2-B06-OC S300-PA-2-M06-OC S300-PA-2-F06-OC S300-PA-2-G00-EX** *24-240VAC/24-60VDC AC voltage untis only. **No ADJ, No Timer, No Outputs. Connections G Connections A, B, C, M, F Timing Functions AC Modles DC Modles AC Modles DC Modles Five selectable timing functions: one shot, ON delay, OFF delay, ON/OFF delay and normal mode. Trimmer adjustment of the functions is available.The timing functions can be particularly useful in applications where the output signal pulse has to be modified. DAT 308

COMPLETE RANGE OF CONTRAST, REGISTRATION MARK,» Type DC TLU Series TL46 Series Trimmer Basic • Nominal Voltage 10-30VDC • World leading mark sensors • Red/green or white LED emission • Rotatable connector Sensing Distance 6-12mm 6-12mm 6-12mm DC Supply Voltage Setting 10-30VDC 10-30VDC 10-30VDC Output LED Teach-in with 2 Pushbuttons / Remote Multi Turn Digital Trimmer for an easy and Automatic Emission Spot quick adjustment of the switching threshold Spot Dimension Output Red Output / Green Ready Yellow Output / Green Ready / Orange Yellow Output / Green Ready Analogue Output Indicator Arrows Output Current Saturation Voltage Red / Green LED White 400-700nm RGB LED Response Time Switching Frequency Vertical Horizontal Vertical Vertical Horizontal Operation Mode Mechanical Protection 1.5 x 5mm 1.5 X 5mm 1.5 X 5mm Housing Material Operating Temperature NPN and PNP NPN and PNP Programmable NPN or PNP Programmable Connections Dimensions Yes 0-5VDC 0.5-5.5VDC on white target 0.5-5.5VDC on white target 200mA Max <100mA Max <100mA Max 1V max (NPN Version) 2V Max (PNP Version) < 2V < 2V 50us 25us 33us 10KHz 20KHz 15KHz Automatic Dark/Light Selection Dark/Light with switch Dark/Light selectable IP67 IP67 IP67 ZAMA Aluminium Aluminium -10o to 55oC -10o to 55oC -10o to 55oC 3m 6.1mm Shielded Cable *M12 4-Pole connector *M12 5-Pole Connector *M12 5-Pole Connector M5 M5 OUTPUT: NPN & PNP (Programmable) - - - TL46-W-815 TL46-W-815L - - NPN Cable TLU-011** TLU-011**L TL46-A-425 - - - -LIMIT & PRESSURE SWITCHES & SENSORS PNP Cable TLU-111** TLU-111**L TL46-A-415 - - NPN-NO RS485 - - - PNP-NO RS485 - - - **For plug type replace 1 with 5 e.g. TLU-115 For sensor cable and accessories see pages 329-332 Wiring Diagrams Trimmer Verion309 Basic Standard and Enhanced Versions ** For plug and cable use part number CS-A1-03-G-03 DAT

TL46 Series »COLOUR AND LUMINESCENCE SENSORS IP67Standard Luminescence LD46 Series Colour S65-V Series Enhanced RGB6-12mm 6-12mm 10-20mm 5-45mm10-30VDC 10-30VDC 15-30VDC 10-30VDCAutomatic / Manual / Remote Automatic / Manual / Remote / Dynamic Manual using +, - and SET push buttons SET & SEL push buttonsYellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ Yellow Output / Green Ready / Orange Delay/ 4 Digit Display Green active Outputs, yellowOrange Keylock / 5 Segment Bargraph Orange Keylock / 4 Digit Display Orange Keylock / 5 Segment Bargraph or function outputRGB LED RGB LED LED UV, 375nm White LED 400-700nmVertical Horizontal Vertical Horizontal1.5 X 5mm 1.5 X 5mm 2 x 8mm at 10mm 4mm at 20mmNPN or PNP Programmable NPN or PNP Programmable 1 x NPN 1 x PNP 3 x PNP or NPNYes 0-5VDC Yes 0-5VDC<100mA Max <100mA Max <100mA Max <100mA Max< 2V < 2V < 2V < 2V25us 17us 250us 335us20KHz 30KHz 2KHz 1.5KHzDark/Light Selectable Dark/Light Selectable Light C or C+I Independant for each channelIP67 IP67 IP67 IP67Aluminium Aluminium Aluminium ABS-10o to 55oC -10o to 55oC -10o to 55oC -10o to 55oC*M12 5-Pole Connector *M12 5-Pole Connector *M12 - 5 Pole Connector *M12 - 8 Pole Connector M5 M5TL46-WL-815 TL46-WL-815L TL46-WFL-815 TL46-WFL-815L LD46-UL-715 -- - -- - -- - -- - S65-PA-5-V09-NNNZ- - -- - S65-PA-5-V09-PPPZ LIMIT & PRESSURE SWITCHES & SENSORS -- - M12 Connector -- -For sensor cable and accessories see pages 329-332 ** For plug and cable use part *Available only for version with RS485 number CS-A1-03-G-03 serial connection (S65-PA-5-V09-xxxZ) ** For plug and cable use part DAT number CS-A1-06-B-03 310

Type DC M18 DC LASER PNP/NPN NO-NC IP67 Laser Emitter S50 SERIES Laser Diffuse Proximity Laser Retro-Reflective Laser Receiver 0-60m 10-30VDC • Output: NPN or PNP NO-NC Red Laser 650nm² • Output Current: ≤100mA max. Sensitivity trimmer • Response Time 333µs Green/Yellow • Housing Material: PBT 1.5kHz • Temperature Range: -10 to 50°C Sensing Distance 0-350mm 0-16m 0-60m Supply Voltage 10-30VDC 10-30VDC 10-30VDC Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm² Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Output LED Green/Yellow Green/Yellow Green/Yellow Switching Frequency 1.5kHz 1.5kHz 1.5kHz Dimensions OUTPUT: S50-PL-5-C01-PP S50-PL-5-B01-PP S50-PL-5-F01-PP – PNP NO-NC M12 S50-PL-5-C01-NN S50-PL-5-B01-NN S50-PL-5-F01-NN – NPN NO-NC M12 – – – S50-PL-5-G00-XG Emmitter Wiring Diagrams Laser Emitter For Sensor Cables and accessories see page 329-332 Type DC DC LASER PNP/NPN NO-NC IP67 S60 SERIES Laser diffuse proximity Laser Retro-Reflective Laser Receiver • Output: NPN or PNP NO-NC • Output Current: ≤100mA max. • Response Time 250µs • Housing Material: ABS • Temperature Range: -10 to 50°CLIMIT & PRESSURE SWITCHES & SENSORS Sensing Distance 0-600mm 0.1-20m 0-60m 0-60m Supply Voltage 10-30VDC 10-30VDC 10-30VDC 10-30VDC Emission Red Laser 650nm² Red Laser 650nm² Red Laser 650nm² Red Laser 650nm² Setting Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Output LED Green/Yellow Green/Yellow Green/Yellow Green/Yellow Switching Frequency 2kHz 2kHz 1.5kHz 1.5kHz Dimensions OUTPUT: S60-PL-5-C01-PP S60-PL-5-B01-PP S60-PL-5-F01-PP – S60-PL-5-C01-NN S60-PL-5-B01-NN S60-PL-5-F01-NN – PNP NO-NC M12 – – – S60-PL-5-G00-XG NPN NO-NC M12 Emitter DAT Wiring Diagrams For Sensor Cables and accessories see pages 329-332 311

ECONOMY U-SHAPE SENSORS 2mm SLOT SENSORS IP65 SR31 Series 30mm SR22 Series 1mm Slot Width 2mm 2mm SR21 Series Fork Slot • High 25kHz switching frequency• Output Current: 200mA max. • Detection of semi-transparent• Switching Frequency 10kHz labels • Detection of register marks on transparents • NPN and PNP output • Output: NPN & PNP • Output Current: 100mA Sci Protection • Housing Material: ZAMA • Temperature Range: -20 to 60°CDC Supply Voltage 10-30VDC 24VDC DC Supply Voltage 10-30VDC 10-30VDCSettingOutput LED Multi-turn Sensitivity Trimmer Trimmer Emission Infrared LED 880nm Green LED 535nmOutputOperation Mode Red Output Red Output Setting Auto Set push-button Auto Set push-buttonHousing MaterialWiring Diagrams NPN or PNP NPN & PNP Resolution 0.5mm 0.5mm Dark/Light Configurable Dark and Light Output LED Yellow Yellow ZAMA Aluminium Operating Mode Light/Dark Light/Dark Wiring DiagramsLight Mode Dark ModeOUTPUT: For plug and cable use part number CS-B1-02-G-05/03 For sensor cable and accessories see pages 329-332NPN & PNP (programmable) SR31 – SR22-5-IR-ODDark Mode – SR22-5-IR-OL OUTPUT: PNP & NPN M8Light Mode – SR21-IR SR21-RGULTIMATE PRECISION FORK TYPE PHOTOELECTRIC SENSOR PNP/NPN MODEFork Width IP65 30mm 50mm 80mm 120mmSRF SERIES 10-30VDC 10-30VDC 10-30VDC 10-30VDC Red LED 640nm² Red LED 640nm² Red LED 640nm² Red LED 640nm²• Nominal Voltage 10-30VDC Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer Sensitivity trimmer• Output: NPN or PNP 0.3mm 0.5mm 0.5mm 0.8mm• Output Current: 200mA Sci Protection Red LED Red LED Red LED Red LED• Switching Frequency: 1.5kHz 333µs 333µs 333µs 333µs• Housing Material: Anodised Aluminium Light/Dark Light/Dark Light/Dark Light/Dark• Temperature Range: -10 to 60°C• High resolution with visible red LED M8 Connector emission• Sensitivity adjustment trimmer• Sturdy industrial metal housing with glass lensesDC Supply VoltageEmission LIMIT & PRESSURE SWITCHES & SENSORSSettingResolutionOutput LEDResponse TimeOperation ModeWiring DiagramsOUTPUT: SRF-30-5-P SRF-50-5-P SRF-80-5-P SRF-120-5-PPNP NO-NC Selectable M8NPN NO-NC Selectable M8 SRF-30-5-N SRF-50-5-N SRF-80-5-N SRF-120-5-N For plug and cable use part no. CS-B1-01-G-05 (axial) For sensor cable and accessories see pages 329-332 Lazer models available on request DAT 312

SLOT SENSORS IP65 ULTRASONIC FORK SENSOR IP54 Slot Sensor SR23 Series 5mm Slot Sensor SRX3 Series 3mm SR23 SERIES SRX3 SERIES For Transparent Label Detection • Setting: Auto Set Push-Button • Output: NPN & PNP For Sensor Cables and 12 kHz 12 kHz Switching Speed 500Hz accessories see pages 10-30VDC 10-30VDC DC Supply Voltage 10-30VDC 329-332 Infrared LED 850nm Infrared LED 850nm Emission Ultrasonic 0.5mm 0.5mm Max tape Speed 300m/min Switching Speed Yellow. Green (Ready) Yellow. Green (Ready) Settings Dynamic/Static Teach-in DC Supply voltage 100mA 100mA Output LED Emission 2v 2v Output Current Yellow Resolution 40us 40us Output 250mA Output LED class 2 class 2 Response Time PNP/NPN Output current Zinc Alloy Zinc Alloy Housing Material 1ms Saturation voltage -25° to 55°C -25° to 55°C Ingress Protection Aluminium Response Time 2m Cable M8 4-pole Connections IP54 Electrical Protection M12 5-Pole Connector M8 4-Pole Connector Housing Material Cable M8 Connector Wiring Diagrams Operating temperature M12 Connector - 5 Pin M8 Connector - 8 Pin Connection Wiring Diagrams OUTPUT: SR23-2-IR-NH SR23-5-IR-NH OUTPUT: SRX3-5-US-M12-PNH SRX3-6-US-M8-PH NPN SR23-2-IR-PH SR23-5-IR-PH PNP/NPN Dynamic SRX3-5-US-3-M12-PNH SRX3-6-US-3-M8-PH PNP PNP/NPN Static ULTRASONIC SENSORS FOR MEASUREMENT AND INSPECTION IP67 Type DC M18 M30 M50 US SERIES • Nominal Voltage: 10-30VDC • Output: NPN & PNP / 0-10VDC / 4-20mA • Output Current: 100mA max. • Complete Range Sensing Distance 30-300mm 100-1000mm 200-2000mm 0.2-8m Setting Teach-in Or Remote Input Teach-in Push button / Remotely / Analogue Push Button Output LED Yellow-Green Output / Red Power Yellow Output / Green Power ON / Green Power On / Red Signal / Red Signal Yellow, Red OutputLIMIT & PRESSURE SWITCHES & SENSORS Housing Material Polyester PBT ABS Polycarbonate Operating Temperature -25° to 55°C -40° to 70°C -20° to 70°C Connections M12 5-pole Connector M12 4-pole Connector M12 5-pole Connector Wiring Diagrams M12 4-POLE CONNECTOR M12 5-POLE CONNECTOR Analogue Analogue NPN Output PNP Output Digital Digital OUTPUT: NPN & PNP US18-PA*-5-N03-OH US30-PR-5-N13-OH US30-PR-5-N23-OH US50-PR-5-N43-OH Analogue Output 0 - 10 VDC US18-PA*-5-N03-VH US30-PR-5-N13-VH US30-PR-5-N23-VH US50-PR-5-N43-IVH Analogue Output 4 - 20 mA US18-PA*-5-N03-IH US30-PR-5-N13-IH US30-PR-5-N23-IH (0-10V / 4-20mA Configurable Output) * For radial type replace A with R e.g. US18-PR-5-N03-OH For sensor cable and accessories see pages 329-332313 DAT

TIME OF FLIGHT LASER MEASUREMENT DISTANCE SENSORSType DC Analogue Distance Analogue Distance Analogue Distance Analogue Distance Analogue DistanceS80 SERIES S80 Series S80 Series S80 Series S80 Series S81 Series Cost EffectiveDistance 0.3-4m 0.3-7m 0.3-20.3m (on R80 reflector) 0.3-100.3m (on R80 reflector) 0.3-4mDC Supply VoltageDigital Resolution 15-30VDC 15-30VDC 15-30VDC 15-30VDC 24VDC +/-20%LinearitySwitching Frequency 0.9mm 0.4mm 0.6mm 6mmLight EmissionResponse Time 0.3% 0.3% 0.25% 0.15% <1%Serial InterfaceSettings 100Hz(normal)/500Hz(fast) 100Hz 100Hz(normal)/500Hz(fast) 100Hz(normal)/500Hz(fast) 80HzOutput Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser cl.2 Red Laser 665nm, cl.2ContactConnection 5ms(normal)/1ms(fast) 5ms 5ms(normal)/1ms(fast) 5ms(normal)/1ms(fast) 5msElectrical ProtectionHousing Material RS485 RS485 RS485 RS485 -Ingress ProtectionOperating Temperature Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-button Teach-in push-buttonDimensions 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2 x PNP 4-20mA analogue 2PNP or NPN outputs 1PNP or NPN alarm output (only S81...M) 1analogue 0-10V output (S81...Y) NO NO NO NO - M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 8-pole connector M12 5-pole connector Class 2 Class 2 Class 2 Class 2 Class 2 Aluminium Aluminium Aluminium Aluminium ABS IP67 IP67 IP67 IP67 IP67 -10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C -10° to 50°C S80 S81OUTPUT:2 x PNP 4 - 20mA S80-MH-5-Y09-PP*IZ S80-MH-5-YL09-PP*IZ S80-MH-5-Y19-PP*IZ S80-MH-5-Y29-PP*IZ - - - S81-PL-5-M03-PP*C2 x PNP 1 x PNP Alarm B- ackground suppression - - - S81-PL-5-Y03-PP*V - - S81-PL-5-Y03-PPVK2 x PNP 0-10V Analogue - - LIMIT & PRESSURE SWITCHES & SENSORS S80L-Y S81-M S81-Y2 x PNP Scalable 0-10V Analogue - -Wiring Diagrams *For NPN replace PP with NN E.g. S80-NG-5-Y09-NNDetection Diagrams For plug and cable use part no. S81 Series CS-A1-06-B-03.Use only R80 reflector S80 Series DAT 314

DC FIBRE OPTIC AMPLIFIERS AND CABLES IP65 DIN RAIL Type DC Through Beam + Proximity Through Beam + Proximity Through Beam + Proximity S7 SERIES • 10 bit resolution models with 500µs response for high operating distances • 12 bit resolution models with 50µs response and 4 digit display for high speed • Cost-effective models with multiturn trimmer adjustment • EASYtouch™ push-button setting with remote control, keylock and output delay • Ultra-thin housing with CLEARLOCK™ patented fibre fixing system Switching Frequency 1KHz 5KHz 10KHz Sensing Distance 100mm Prox. 300mm Through Beam 50mm Prox. 300mm Through Beam 25mm Prox. 75mm Through Beam DC Supply Voltage 12-24VDC ±10% 12-24VDC ±10% 12-24VDC ±10% Emission Red LED 670nm Red LED 670nm White LED 460-630nm Setting Teach-in push-button Teach-in push-button Teach-in push-button Output LED Yellow/Green/Red error Yellow/Green/Red error Yellow/Green/Red error Output PNP or NPN PNP or NPN PNP or NPN Contact NO NO NO Output current ≤100ma ≤100ma ≤100ma Saturation Voltage ≤2V ≤2V ≤2V Response Time 500µS 100µs 500µs Timing Function 20ms minimum out ON 20ms minimum out ON 20ms minimum out ON Operation Mode light with EASYtouch™ light with EASYtouch™ light with EASYtouch™ Plug Type Wiring Diagrams OUTPUT: NPN output PNP output PNP NO M8 Plug S7-6-E-P – – – – NPN NO M8 Plug S7-6-E-N S7-5-E-P – S7-5-E-N – PNP NO M8 Plug Dispaly – S7-2-E-P S7-1-E-P S7-2-E-N S7-1-E-N NPN NO M8 Plug Display – PNP NO Cable Display – NPN NO Cable Display – For plug and cable use part number CS-B1-02-G-05/03 Fibre Optic Cables Stainless Steel Protective Metal Sheath 2m Optic Function Terminal/Tips Fibre Type Length Part Number Part Number Suitable Fibres Coaxial Proximity M6 x 1mm Standard 1mm 2m OF-36-ST-20 AF-7 M6 x 0.75mm fibres OF-42-xx OF-18-ST-10 Proximity M6 x 1mm Standard 1mm 1m OF-22-ST-20 AF-9 M4 x 0.7mm fibres OF-43-xx** OF-26-TN-10LIMIT & PRESSURE SWITCHES & SENSORS Proximity M6 x 1mm* Standard 1mm 2m OF-42-ST-20 OF-42-HP-20 Proximity M3 x 0.5mm Thin 0.5mm 1m OF-19-ST-10 OF-23-ST-20 Proximity M6 x 0.75mm Standard 1mm 1m OF-25-TN-10 OF-43-ST-20 Proximity M6 x 0.75mm High Efficiency 1.5mm 2m OF-43-HP-20 Through Beam M4 x 0.7mm Standard 1mm 1m Through Beam M4 x 0.7mm* Standard 1mm 2m Through Beam M2 x 0.4mm Thin 0.5mm 1m Through Beam M4 x 0.7mm Standard 1mm 1m AF-7 Dimensions Through Beam M4 x 0.7mm High Efficiency 1.5mm 2m AF-9 Dimensions Application Fibre Optics ** 2 Sheaths have to be ordered for both the emitter-receiver fibres Optic Function Terminal/Emission Fibre Length Part Number Through Beam Axial, 16 Beam Array 2m OFA-1-AE-20 Through Beam Radial, 16 Beam Array 2m OFA-1-AS-20 Proximity Axial, 32 Beam Array 2m OFA-2-AE-20 Proximity Radial, 32 Beam Array 2m OFA-2-AS-20 * A bendable stainless steel extension 90mm long protrudes from the threaded optic head315 DAT

PHOTOELECTRIC SENSORSLong Range Photoelectric Sensors IP54Type Through Beam Kits Through Beam Kit for Note: Each kit includes emitter and receiver. Automatic Doors Receiver Emitter Receiver Emitter Receiver Emitter Receiver Emitter Battery operated 9V Ideal for P41 – surface mount P40 – flush mount emitter-150 days minimum automatic gates Solar cell power supply on request Note: Each kit includes 1 pair of projectors. 10MSwitching Distance 15M 35M 55M 15M One Beam SelectionAvailable Receiver & Emitter Receiver & Emitter Receiver & Emitter Receiver & Emitter Infrared (875hm)Emission Infrared (875nm) Infrared (875nm) Infrared (875nm) Relay: 8A @ 250VAC 70mAOutput 2 Relay SPDT Relay: 1A @ 24VDC 2 Relay Output and activated thru beam indicatorConsumption 40mA 40mA 70mA Supply indicator PresentYellow LED Output Indicator Output indicator Output Indicator 5Hz 200mSGreen LED Supply Indicator Supply indicator Supply Indicator ≤ 300mS -20° to 60°CSensitivity Adjustment – – – > 5000 LuxSwitching Frequency 50Hz - 60Hz 5Hz 1Hz Amplifiers IP54. Projectors IP65 Amplifiers ABS. Projectors Body – Lenses: methacrylateResponse Time – – 500mS 350 gStart Up Delay ≤ 300mS ≤ 300mS ≤ 300mS 12VAC/DC BP10-120Ambient -20° to 60°C -20° to 60°C -20° to 60°C 24VAC/DC BP10-240Light Immunity 230VAC/DC BP10-220 > 5000 Lux > 5000 Lux > 5000 Lux(1) Wiring DiagramProtection Degree IP54 IP54 IP54 8AHousing Material PMMA Housing: glass-filled nylon – Filter: methacrylateWeight (Approx) 160 g 315 g 340 g12-24VAC/DC P63 P 41 P40 P449V alkaline battery P44 230VAC/DC – – – –Wiring Diagram Wiring Diagram for Wiring Diagram for P44 EMITTER P63, P40 & P41 EMITTER RECEIVER RECEIVER 12VAC/DC or 24VAC/DCAccessories for P41 8A ▼ C41080 105 Anti-Vandalism Projector Dimensions ▼ Box (grey) 500 LIMIT & PRESSURE SWITCHES & SENSORSCharacteristic Curve BP10 ▼ 88 S410 ▼ 75 316 15 ▼ ▼ ▼ 85 77 4.5 Metal Box ▼ 42 wall mounting (grey) 28 SI41 30 Metal Post (grey) 65Accessories for P40 85 Solar Accessory for P44 C340 Box for wall SCP44 75 mounting Battery operated 9V emitter-150 (grey) 530 days minimum. Solar cell power supply on request. 75 ▼ S340 Metal Post (grey) ▼ 60 DAT