Model 25FD Flush Panel Swing Door EXIT DEVICE LOCATIONS1-3/8” [35.74mm] 39-13/16” TO FINISHED FLOOR 42” TO FINISHED FLOOR 45-15/16” TO FINISHED FLOOR YKK AP  DOR-O-MATIC® 1790 VON DUPRIN® 33SMART PUSH/PULL 39-11/16” TO FINISHED FLOOR 39-13/16” TO FINISHED FLOOR VON DUPRIN® 99 VON DUPRIN® 99 (Single) (Pair)Effective Date: September 15, 2016 | 01-1005-02 Page-7



35H/50H



35H/50H Impact Resistant and Blast Mitigating Entrance TABLE OF CONTENTS35H/50H PRODUCT DATA ......................................................................... Page 235H FRAMING MEMBERS ......................................................................... Pages 3 to 1435H THRESHOLD OPTIONS­...................................................................... Page 1550H FRAMING MEMBERS ......................................................................... Pages 16 to 2750H THRESHOLD OPTIONS­...................................................................... Page 28*The latest installation instructions for this product are available at www.ykkap.com. Page-1Effective Date: May 18, 2015 | 01-1001-08

> Model 35H/50H Impact Resistant and Blast Mitigating Entrance SystemProtection You Can Count OnThe industry’s most durable entrance system is nowavailable in medium and wide stile versions. In additionto a comprehensive array of locking and hinging options,this product is available with monolithic or 1” insulatinglaminated glass for medium and wide stile applications.Mid-Rail and bottom rail options provide additional designflexibility for the specifier.YKK AP has also addressed ongoing maintenance inabusive environments, such as schools and military bases.To reduce maintenance costs choose either rim panicexit devices combined with an impact rated aluminumremovable mullion, or single point locks paired with flushbolts on the inactive panel. These institutional gradeentrance systems provide maximum security under themost demanding conditions without the need for steelreinforcing. They also integrate with YHS storefront andYHC curtain wall framing systems.Model 35H and 50H entrances are Large and Small MissileImpact resistant tested, as well as Blast MitigationTested. With the expansion of hardware and performanceoptions, they are your single source for hurricane resistant,government, and DoD applications.Product Benefits n Large & Small Missile Impact – To 90 PSF n Florida Product Approval – HVHZ n Blast Mitigation Testing – ASTM F 1642 – Minimal Hazard n YKK AP VersaJamb® Door Frame n Water Performance – ASTM E 331 – 10.5 PSFEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors

35H Impact Resistant and Blast Mitigating Entrance 35H GLASS RAIL AND STILE OPTIONS STANDARD STANDARD PANIC MID RAIL PANIC PUSH/PULL 1 1A Mid Rail Panic Standard Device Panic 5,5A Device Standard 3,3A 4 Push/Pull 2 For hardware location, see pages 4 through 6 of Entrance Hardware section. 4-11/16” [119.1mm] 7-1/4” [184.2mm] E9-0220 E9-0221 2-3/8” SECTION 1A [60.32mm] 2-3/8” SECTION 1 [60.32mm] 4-13/16” [122.2mm] E9-0238 4” [101.6mm] E9-0226 E9-0235 E9-0225 E9-02227-1/4” [184.2mm] 10” [254.0mm] E9-0233 12” [304.8mm] 8” [203.2mm] 4-11/16” E9-0221 7-3/16” [182.6mm] [119.1mm] SECTION 5 OFFSET HUNG SECTION 2 SECTION 3 SECTION 3A SECTION 4 E9-0226 E9-02367-1/4” BOTTOM RAIL 8” BOTTOM RAIL OPTIONAL 10” OPTIONAL 12” E9-0225 BOTTOM RAIL* STACKED BOTTOM RAIL 4-11/16” [119.1mm] SECTION 5A CONTINUOUS HINGEEffective Date: May 18, 2015 | 01-1001-08 Page-3

35H Impact Resistant and Blast Mitigating Entrance 35H GLASS MID-RAIL OPTIONS MID RAIL PANIC MID RAILS Mid Rail 3,3A Panic Device 1 29-1/8” [231.7mm] E9-0237 9-1/8” [231.7mm] E9-0235 5-7/8” [146.8mm] E9-0220 E9-0217 E9-0217 E9-0217 SECTION 3 SECTION 1 SECTION 2 5-3/4”MID RAIL9-1/8” MID RAIL PANIC DEVICE W/ WET GLAZE OPTION* 9-1/8” MID RAIL* E9-0220 E9-02175-7/8” [146.8mm]Page-4 SECTION 3A 5-3/4”MID RAIL W/ DRY GLAZE OPTION* 01-1001-08 | Effective Date: May 18, 2015

35H Impact Resistant and Blast Mitigating Entrance 35H AND YHS 50 FRAMING2,3 4,6 5,7 (Use with Air Only Threshold) 1,1ASECTION 1 SECTION 1A SECTION 2 SECTION 3 SECTION 5 SECTION 4 SECTION 7 SECTION 6 Page-5Effective Date: May 18, 2015 | 01-1001-08

35H Impact Resistant and Blast Mitigating Entrance 35H AND YHS 50 FRAMING AS-0504 AS-0504 AS-05041,1A 2 4 SECTION 1B 3 SECTION 2 SECTION 2A SECTION 3 SECTION 4 SECTION 4A* Offset Hung Refers to Location of the Door in the Frame and not Hinging HardwarePage-6 01-1001-08 | Effective Date: May 18, 2015

35H Impact Resistant and Blast Mitigating Entrance 35H AND YHC 300 FRAMING2,4 3,5 1,1ASECTION 1 SECTION 1ASECTION 2 SECTION 3 SECTION 4 SECTION 5Effective Date: May 18, 2015 | 01-1001-08 Page-7

35H Impact Resistant and Blast Mitigating Entrance 35H AND YHC 300 FRAMING 1,2 SECTION 1 SECTION 1 SECTION 2Page-8 01-1001-08 | Effective Date: May 18, 2015

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS RAIL AND STILE OPTIONS 1 3A 1A3 2B2 2A For hardware location, see pages 4 through 6 of Entrance Hardware section. SECTION 1ASECTION 1 E9-02555” [127.0mm] 4-3/16” [106.4mm] SECTION 3 E9-0245 12-3/16” [309.6mm] E9-0235 8” [203.2mm] 7-3/16” [182.6mm] SECTION 3A SECTION 2 SECTION 2A SECTION 2B* Nominal Dimension. OPTIONAL 12” STACKED BOTTOM RAILEffective Date: May 18, 2015 | 01-1001-08 Page-9

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS M­­ ID-RAIL OPTIONS 2,3 1,1A 4 11-1/2” [292.1mm]SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 1A 01-1001-08 | Effective Date: May 18, 2015Page-10

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS AND YHS 50 TU FRAMING2,3 4,6 1,1ASECTION 1 SECTION 1A * Offset Hung Refers to Location of the Door in the Frame and not Hinging Hardware SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6Effective Date: May 18, 2015 | 01-1001-08 Page-11

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS AND YHS 50 FRAMING 213,4 5 SECTION 1 AS-0504 SECTION 2AS-0501 SECTION 3 SECTION 4 SECTION 5Page-12 1” DOOR GLAZING 1” DOOR GLAZING 1-5/16” TRANSOM GLAZING 01-1001-08 | Effective Date: May 18, 2015

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS WITH YHC 300 FRAMING2,4 3,5 (Use with Air Only Threshold) 1,1ASECTION 1 SECTION 1ASECTION 2 AS-3178 SECTION 3 SECTION 4 AS-3178Effective Date: May 18, 2015 | 01-1001-08 SECTION 5 Page-13

35H Impact Resistant and Blast Mitigating Entrance 35H FOR INSULATING GLASS WITH YHC 300 FRAMING 1,2 SECTION 1 SECTION 2 OFFSET HUNG* OFFSET HUNG* (OHCC)Page-14 01-1001-08 | Effective Date: May 18, 2015

35H Impact Resistant and Blast Mitigating Entrance 35H THRESHOLD OPTIONS 1A-D1/2\" 1/2\" SECTION 1A SECTION 1B ADA COMPLIANT ADA COMPLIANTAIR ONLY THRESHOLD AIR ONLY THRESHOLD w/ 35H w/ 35H for Insulating GlassSealant Sealant SECTION 1C WATER RESISTANT THRESHOLD w/ ADA EXTERIOR RAMP Sealant SECTION 1D WATER RESISTANT THRESHOLD w/ ADA EXTERIOR/INTERIOR RAMPEffective Date: May 18, 2015 | 01-1001-08 Page-15

50H Impact Resistant and Blast Mitigating Entrance 50H GLASS RAIL AND STILE OPTIONS STANDARD STANDARD PANIC MID RAIL PANIC PUSH/PULL 1 Standard Mid Rail Panic Panic 5,5A Device Device Standard 3,3A 4 Push/Pull 2 For hardware location, see pages E9-0226 4 through 6 of Entrance Hardware section. E9-02255-13/16” [147.7mm] E9-0239 E9-0234 2-3/8” 5-13/16” [60.32mm] [147.7mm] SECTION 1 SECTION 5 OFFSET HUNG E9-0226 E9-0242 E9-0225 5-13/16” [147.7mm] SECTION 5A CONTINUOUS HINGE 4-13/16” [122.0mm] E9-0238 4” [101.6mm]7-1/4” [185.7mm] 8” [203.2mm] 10” [254.04mm] E9-0233 12” [304.8mm] 8” [203.2mm] 7-3/16” [182.60] E9-0221 E9-0235 E9-0235 SECTION 2 SECTION 3 SECTION 4 7-1/4” BOTTOM RAIL 8” BOTTOM RAIL OPTIONAL 12” STACKED BOTTOM RAILPage-16 01-1001-08 | Effective Date: May 18, 2015

50H Impact Resistant and Blast Mitigating Entrance 50H GLASS MID-RAIL OPTIONSMID RAIL PANIC MID RAILSMid Rail 3,3A PanicDevice 1 2E9-02379.123” [321.7mm] E9-0235 9.123” [321.7mm] 6-5/8” [168.3mm] 5.780” [146.8mm] E9-0239 E9-0220 E9-0220 E9-0220 SECTION 1 SECTION 2 SECTION 3 SECTION 3AMID RAIL PANIC DEVICE 9-1/8” MID RAIL* 6-5/8” MID RAIL 5-3/4”MID RAIL W/ DRY GLAZE OPTION* W/ DRY GLAZE OPTION*Effective Date: May 18, 2015 | 01-1001-08 Page-17



































35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - WET GLAZING2,3 4 5 1 E1-1138 E9-0310 E9-0332 E9-0202 E9-0330 E9-0201 8-13/16” [223.8mm] SECTION 1 MEETING STILESE9-0606 AS-0551 AS-0551 E9-0202 E9-0202 E9-0201 E9-0308 E9-0201 E9-0308 SECTION 2 SECTION 3 OFFSET HUNG OFFSET HUNG 9/16” GLAZING SIDELITE 1-5/16” GLAZING SIDELITEE9-0606 AS-0551 AS-0551 E9-1068 E9-0202 E9-0202 E9-0308 E9-0201 E9-0201 E9-0308 SECTION 4 SECTION 5 OFFSET HUNG OFFSET HUNGw/ OPTIONAL STEEL REINFORCEMENTEffective Date: December 8, 2016 | 01-1009-00 Page-5

35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - WET GLAZING 2,2A AS-0551 AS-05511,1A E9-0554 E9-0555 4,4A SECTION 1A 3 SECTION 2 SECTION 2A AS-0552 AS-0552 AS-0553 E9-0306 E9-0306 E9-0306 E9-0201 E9-0202 E9-0201 E9-0202 E9-0201 E9-0202 SECTION 3 SECTION 4 SECTION 4A OFFSET HUNG OFFSET HUNG OFFSET HUNG 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” TRANSOM GLAZING 1-5/16” TRANSOM GLAZINGPage-6 01-1009-00 | Effective Date: December 8, 2016

35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - WET GLAZING2,3 2,3 4 1 E1-1138 E9-0310 E9-0332 E9-0204 E9-0330 E9-0203 8-13/16” [223.8mm] SECTION 1 MEETING STILES AS-0551 E9-0204 E9-0308 E9-0203 SECTION 2 OFFSET HUNG 1-5/16” GLAZING SIDELITEE9-0656 AS-0551 AS-0551 E9-1068 E9-0204 E9-0204 E9-0308 E9-0203 E9-0203 E9-0308 SECTION 3 SECTION 4 OFFSET HUNG OFFSET HUNGw/ OPTIONAL STEEL REINFORCEMENTEffective Date: December 8, 2016 | 01-1009-00 Page-7

35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - DRY GLAZING2,3 4 5 1 E1-1138 E9-0310 E9-0332 E9-0203 E9-0330 E9-0203 8-13/16” [223.8mm] SECTION 1 MEETING STILES E9-0606 AS-0551 AS-0551 E9-0201 E9-0201 E9-0308 E9-0201 E9-0308 E9-0201 SECTION 2 SECTION 3 OFFSET HUNG OFFSET HUNG 9/16” GLAZING SIDELITE 1-5/16” GLAZING SIDELITE E9-0606 AS-0551 AS-0551 E9-1068 E9-0201 E9-0201 E9-0308 E9-0201 E9-0201 E9-0308 SECTION 4 SECTION 5 OFFSET HUNG OFFSET HUNG w/ OPTIONAL STEEL REINFORCEMENTPage-8 01-1009-00 | Effective Date: December 8, 2016

35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - DRY GLAZING 2,2A AS-0551 AS-05511,1A E9-0554 E9-0555 4,4A E9-0506 E9-0506 SECTION 1A3 SECTION 2 SECTION 2A AS-0552 AS-0552 AS-0553 E9-0306 E9-0306 E9-0306E9-0201 E9-0201 E9-0201 E9-0201 E9-0201 E9-0201 SECTION 3 SECTION 4 SECTION 4A OFFSET HUNG OFFSET HUNG OFFSET HUNG 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” TRANSOM GLAZING 1-5/16” TRANSOM GLAZINGEffective Date: December 8, 2016 | 01-1009-00 Page-9

35HL/50HL Impact Resistant Entrance 35HL AND YHS50 FRAMING - DRY GLAZING2,3 2,3 4 1 E1-1138 E9-0310 E9-0332 E9-0203 E9-0330 E9-0203 8-13/16” [223.8mm] SECTION 1 MEETING STILES AS-0551 E9-0203 E9-0308 E9-0203 SECTION 2 OFFSET HUNG 1-5/16” GLAZING SIDELITE E9-0656 AS-0551 AS-0551 E9-1068 E9-0203 E9-0203 E9-0308 E9-0203 E9-0203 E9-0308 SECTION 3 SECTION 4 OFFSET HUNG OFFSET HUNG w/ OPTIONAL STEEL REINFORCEMENTPage-10 01-1009-00 | Effective Date: December 8, 2016

35HL/50HL Impact Resistant Entrance50HL GLASS RAIL AND STILE OPTIONS - WET GLAZING STANDARD STANDARD PANIC PUSH/PULL4,4A 1,1A Standard Panic Standard Device Push/Pull E9-0202 2,2A, E9-0311 E9-0201 3,3A E9-0204 5-13/16” [147.6mm] SECTION 4 OFFSET HUNG 9/16” WET GLAZING5-13/16 ” [147.6mm] E9-0334 E9-0311 E9-0334 5-13/16” [147.6mm] E9-0203E9-0201 E9-0203 SECTION 4A E9-0202 E9-0204 1-3/4” 1-3/4” OFFSET HUNG [44.5mm] [44.5mm] 1” WET GLAZING SECTION 1 SECTION 1A E9-0201 E9-02029/16” WET GLAZING 1” WET GLAZING E9-0203 E9-0204E9-0201 E9-0202 E9-0203 E9-02048-3/4” [22.3.6mm] E9-0317 8-3/4” [22.3.6mm] E9-0317 10-13/16” [274.6mm] E9-0323 10-13/16” [274.6mm] E9-0323 SECTION 2 SECTION 2A SECTION 3 SECTION 3A 8” BOTTOM RAIL 8” BOTTOM RAIL 10” BOTTOM RAIL 10” BOTTOM RAIL9/16” WET GLAZING 1” WET GLAZING 9/16” WET GLAZING 1” WET GLAZINGEffective Date: December 8, 2016 | 01-1009-00 Page-11

35HL/50HL Impact Resistant Entrance50HL GLASS RAIL AND STILE OPTIONS - DRY GLAZING STANDARD STANDARD PANIC PUSH/PULL4,4A 1,1A Standard Panic Standard Device Push/Pull E9-0201 2,2A, E9-0311 E9-0201 3,3A 5-13/16” [147.6mm] SECTION 4 OFFSET HUNG 9/16” DRY GLAZING5-13/16” [147.6mm] 5-13/16” [147.6mm] E9-0203 E9-0334 E9-0334 E9-0311 5-13/16” [147.6mm] E9-0203E9-0201 E9-0203 SECTION 4A E9-0201 E9-0203 1-3/4” 1-3/4” OFFSET HUNG [44.5mm] [44.5mm] 1” DRY GLAZING SECTION 1 SECTION 1A E9-0201 E9-02019/16” DRY GLAZING 1” DRY GLAZING E9-0203 E9-0203E9-0201 E9-0201 E9-0203 E9-02038-3/4” [22.3.6mm] E9-0317 8-3/4” [22.3.6mm] E9-0317 10-13/16” [274.6mm] E9-0323 10-13/16” [274.6mm] E9-0323 SECTION 2 SECTION 2A SECTION 3 SECTION 3 8” BOTTOM RAIL 8” BOTTOM RAIL 10” BOTTOM RAIL 10” BOTTOM RAIL 9/16” DRY GLAZING 1” DRY GLAZING 9/16” DRY GLAZING 1” DRY GLAZINGPage-12 01-1009-00 | Effective Date: December 8, 2016

35HL/50HL Impact Resistant Entrance 50HL AND YHS50 FRAMING - WET GLAZING2,3 4 5 1 E1-1138 E9-0313 E9-0332 E9-0202 E9-0331 E9-0201 11-13/16” [300.0mm] SECTION 1 MEETING STILESE9-0606 AS-0551 AS-0551 E9-0311 E9-0202 E9-0311 E9-0202 E9-0201 E9-0201 SECTION 2 SECTION 3 OFFSET HUNG OFFSET HUNG 9/16” GLAZING SIDELITE 1-5/16” GLAZING SIDELITEE9-0606 AS-0551 AS-0551 E9-0202 E9-0202 E9-1068 E9-0201 E9-0311 E9-0201 E9-0311 SECTION 4 SECTION 5 OFFSET HUNG OFFSET HUNGw/ OPTIONAL STEEL REINFORCEMENTEffective Date: December 8, 2016 | 01-1009-00 Page-13

35HL/50HL Impact Resistant Entrance 50HL AND YHS50 FRAMING - WET GLAZING 2,2A AS-0551 AS-05511,1A E9-0554 E9-0555 4,4A SECTION 1A3 SECTION 2 SECTION 2A AS-0552 AS-0552 AS-0553 E9-0334 AS-0334 AS-0334 E9-0201 E9-0202 E9-0201 E9-0202 E9-0201 E9-0202 SECTION 3 SECTION 4 SECTION 4A OFFSET HUNG OFFSET HUNG OFFSET HUNG 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” DOOR GLAZING 9/16” TRANSOM GLAZING 1-5/16” TRANSOM GLAZINGPage-14 01-1009-00 | Effective Date: December 8, 2016

35HL/50HL Impact Resistant Entrance 50HL AND YHS50 FRAMING - WET GLAZING2,3 2,3 4 1 E1-1138 E9-0332 E9-0204 E9-0313 E9-0331 E9-0203 11-13/16” [300.0mm] SECTION 1 MEETING STILES AS-0551 E9-0311 E9-0204 E9-0203 SECTION 2 OFFSET HUNG 1-5/16” GLAZING SIDELITEE9-0656 AS-0551 AS-0551 E9-0204 E9-0204 E9-1068 E9-0311 E9-0203 E9-0203 E9-0311 SECTION 3 SECTION 4 OFFSET HUNG OFFSET HUNGw/ OPTIONAL STEEL REINFORCEMENTEffective Date: December 8, 2016 | 01-1009-00 Page-15

35HL/50HL Impact Resistant Entrance 50HL AND YHS50 FRAMING - DRY GLAZING2,3 4 5 1 E1-1138 E9-0313 E9-0332 E9-0201 E9-0331 E9-0201 11-13/16” [300.0mm] SECTION 1 MEETING STILES E9-0606 AS-0551 AS-0551 E9-0311 E9-0201 E9-0311 E9-0201 E9-0201 E9-0201 SECTION 2 SECTION 3 OFFSET HUNG OFFSET HUNG 9/16” GLAZING SIDELITE 1-5/16” GLAZING SIDELITE E9-0606 AS-0551 AS-0551 E9-0201 E9-0201 E9-1068 E9-0201 E9-0311 E9-0201 E9-0311 SECTION 4 SECTION 5 OFFSET HUNG OFFSET HUNG w/ OPTIONAL STEEL REINFORCEMENTPage-16 01-1009-00 | Effective Date: December 8, 2016