Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore YKK-AP-VOL1

YKK-AP-VOL1

Published by jwoodward.imagemarkonline, 2017-08-31 13:39:42

Description: YKK-AP-VOL1

Search

Read the Text Version

35HL/50HL Impact Resistant Entrance 50HL AND YHS50 FRAMING - DRY GLAZING2,3 2,3 4 1 E1-1138 E9-0332 E9-0203 E9-0313 E9-0331 E9-0203 11-13/16” [300.0mm] SECTION 1 MEETING STILES AS-0551 E9-0311 E9-0203 E9-0203 SECTION 2 OFFSET HUNG 1-5/16” GLAZING SIDELITEE9-0656 AS-0551 AS-0551 E9-0203 E9-0203 E9-1068 E9-0311 E9-0203 E9-0203 E9-0311 SECTION 3 SECTION 4 OFFSET HUNG OFFSET HUNGw/ OPTIONAL STEEL REINFORCEMENTEffective Date: December 8, 2016 | 01-1009-00 Page-17

35HL/50HL Impact Resistant Entrance 35HL/50HL Threshold Options 1,2 E1-1138 E9-0347 E9-0348 SECTION 1 E2-0067 W/ THRESHOLD STOP SECTION 2Page-18 W/ DOOR SWEEP 01-1009-00 | Effective Date: December 8, 2016

35XT/50XT



MegaTherm® XT Entrances TABLE OF CONTENTS MegaTherm® XT ENTRANCES MODEL 35XT / 50XTPRODUCT DATA........................................................................................ Page 235XT / 50XT DOOR FRAMING MEMBERS (1/4 SIZE)............................ Pages 335XT FRAMING MEMBERS (1/4 SIZE).................................................... Pages 4 to 550XT FRAMING MEMBERS (1/4 SIZE).................................................... Pages 6 to 735XT / 50XT SUBFRAMING (1/4 SIZE).................................................... Page 8*The latest installation instructions for this product are available at www.ykkap.com.Effective Date: September 15, 2016 | 01-1004-04 Page-1

> Megatherm® XT Energy Saving Model 35XT and 50XT Swing DoorsBest in Class Thermal PerformanceArchitects seeking LEED certification can enhancea project’s energy conservation by specifying YKK AP’s newhigh-performance MegaTherm® XT thermal entrances. AModel 35XT Entrance has a U-factor of 0.52 (UCOG = 0.29).Testing has also been conducted with advanced glazing toachieve a U-factor of 0.44, exceptional performance for anarchitectural aluminum entrance.To save energy, all aspects of the doors, includingthe frames and thresholds, are thermally broken by YKK AP’sMegaTherm® polymer, which separates the interior andexterior extrusions by more than 0.270 inches to reduceenergy flow. Thermal entrances feature foam polymerinserts and dual perimeter air seals for superior performanceover standard entrances.Thermal entrances are available in mediumstile, Model 35XT and wide stile, Model 50XTconfigurations. A wide selection of hardwareoptions for hinges, locks, closers, mid-rails, and bottom railsare available. Framing solutions integrate into most YKK APsystems utilizing MegaTherm® or ThermaBond Plus® thermalbreaks. Door corners are mechanically joined/welded andcarry a lifetime warranty.MegaTherm® XT entrances accept standard 1\" insulatingglazing units as well as advanced glazing, including 1-3/8”suspended film glazing. enerGfacadeEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors

MegaTherm® XT Entrances For hardware location, see pages 4 through 6 of Entrance Hardware section.* Nominal Dimensions. Page-3Effective Date: September 15, 2016 | 01-1004-04

MegaTherm® XT Entrances MODEL 35XT FRAMING MEMBERSPage-4 01-1004-04 | Effective Date: September 15, 2016

MegaTherm® XT EntrancesMODEL 35XT FRAMING MEMBERSEffective Date: September 15, 2016 | 01-1004-04 Page-5

MegaTherm® XT Entrances MODEL 50XT FRAMING MEMBERSPage-6 01-1004-04 | Effective Date: September 15, 2016

MegaTherm® XT EntrancesMODEL 50XT FRAMING MEMBERSEffective Date: September 15, 2016 | 01-1004-04 Page-7

MegaTherm® XT Entrances SUBFRAME OPTIONSPage-8 01-1004-04 | Effective Date: September 15, 2016













































YES 40 FS/FI



YES 40 FS/FI Storefront System TABLE OF CONTENTSPRODUCT DATA.......................................................................................... Page 2PICTORIAL VIEWS....................................................................................... Page 3 to 4 YES 40 FS STOREFRONT SYSTEM FOR 1/4\" GLAZING 1-3/4\" x 4\"FRAMING MEMBERS (1/4 SIZE)................................................................ Page 5 to 6WIND LOAD & DEAD LOAD CHARTS...................................................... Page 7 to 8 YES 40 FI STOREFRONT SYSTEM FOR 1\" GLAZING 2\" x 4\"FRAMING MEMBERS (1/4 SIZE)................................................................ Page 9 to 10WIND LOAD / DEAD LOAD CHARTS........................................................ Page 11 to 12*The latest installation instructions for this product are available at www.ykkap.com.Effective Date: September 15, 2016 | 02-1001-02 Page-1

> YES 40 FS/FI Outside Glazed Storefront SystemsSYSTEM DESCRIPTION:YES 40 FS (1-3/4” x 4”) is a center set, flush glazedframing systems designed primarily for 1/4” glass orinfill panels 1/4” to 3/8” thick. YES 40 FI (2” x 4”) is acenter set, flush glazed framing system developed for1” insulating glass and other types of infill panels ofvarying thicknesses. Both systems will accommodateYKK AP’s hinged mullion, as well as our flexiblemullion; these mullions allow more creative freedomwhere curves and angles become a functional part ofthe design.OPTIONS & FEATURES: n Outside Glazed n Screw Spline or Shear Block Assembly n Gasket With Stretch-Resistant Cord n Integral Entrance Door Frames n Enhanced Water Infiltration ResistanceEntrances | Storefronts | Curtain Walls | Sun Controls | Windows | Balcony Doors

YES 40 FS/FI Storefront SystemThe Screw Spline Assembly method uses Page-3a two piece vertical mullion. This allows the frameto be constructed in units using screws driven throughthe back of the vertical mullions into the screw splinesof the horizontal members. The units are then snappedtogether at the vertical to complete the fabrication.Effective Date: September 15, 2016 | 02-1001-02

YES 40 FS/FI Storefront SystemThe Shear Block Assembly method uses shear blocks 02-1001-02 | Effective Date: September 15, 2016to attach horizontal members to tubular vertical mullions.This allows for a stronger joint connection.Page-4

YES 40 FS/FI Storefront System YES 40 FS FRAMING MEMBERS 1 2 8 10 4 56 9 3 7 111-3/4” E9-1033 E9-1310 [44.5mm] E9-1303 E9-1303 E9-1303 E9-1301 E9-1009 4” [101.6mm] SECTION 1A SECTION 1 HEAD RECEPTOR HEAD E9-1305 E9-1305 SECTION 5 SECTION 4 VERTICAL E9-1306 E9-1304 JAMB E9-1009 SECTION 2 SECTION 2A E9-1301 HORIZONTAL TWO PIECE HORIZONTAL E1-0157 E9-1325 E9-1326 E9-1305 E9-1304 E9-1030 E9-1002 SECTION 3 SECTION 5A SECTION 5B SILL VERTICAL W/ EXPANSION STEEL REINFORCING MULLION SCALE: 1/4 SIZE Page-5 036Effective Date: September 15, 2016 | 02-1001-02

YES 40 FS/FI Storefront System YES 40 FS FRAMING MEMBERSPage-6 02-1001-02 | Effective Date: September 15, 2016

YES 40 FS/FI Storefront System YES 40 FS WIND LOAD CHARTSDEFLECTION CRITERIA: AAMA TIR-A11 - L/175 or L/240 + 1/4\" (6.4mm) - FOR SPANS GREATER THAN 13'-6\" (4.1m) BUT LESS THAN 40'-0\" (12.2m) CODES AND SPECIFICATIONS MAY VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4\" (19.1mm)ALLOWABLE WIND LOAD STRESS YKK AP tested standard. Contact YKK AP for more information.These charts include unbraced length analysis and are based off at least one horizontal being placed at the midpoint of the span. For otherapplications, please contact YKK AP engineers at 1-866-955-2732. E9-1301 / E9-1009 E9-1303 / E9-1009 14 14V VE 13 E 13R RT 12 T 12I 11 I 11C CA 10 A 10L L 9 A Ixx=2.114 in4 Ixx=2.223 in4 H 9 AH B (87.99 cm4) (92.53 cm4) E 8 BE8I7 C I7 CG D G DH6 H6 T A=15 PSF (720 Pa) T 5 5(FT) (FT) 2345 6 7 B=20 PSF (960 Pa) 23 45 6 7 VERTICAL SPACING (FT) C=30 PSF (1440 Pa) VERTICAL SPACING (FT) D=40 PSF (1920 Pa) E9-1301 / E9-1002 / E1-0157 17VE 16RT 15I 14CA 13L 12 Ixx=4.707 in4 (195.92 cm4)HE 11 AI 10 BGH9 C T D 8(FT) 2 3 45 6 7 VERTICAL SPACING (FT)Effective Date: September 15, 2016 | 02-1001-02 Page-7

YES 40 FS/FI Storefront System YES 40 FDSEADDEALDOALODACDHACRHTART 12 E9-1306 O P 11 A E 10 B N9 I N8 G7 H6 E5 I4 G H3 T2 (FT) 1 34 56 7 OPENING WIDTH (FT) A = Setting Blocks at 1/8 Point Locations B = Setting Blocks at 1/4 Point Locations Note: Dead load requirements are based upon a maximum deflection of 1/8\" (3.2mm) at the center of the horizontal.Page-8 02-1001-02 | Effective Date: September 15, 2016

YES 40 FS/FI Storefront SystemYES 40 FI FRAMING MEMBERSEffective Date: September 15, 2016 | 02-1001-02 Page-9

YES 40 FS/FI Storefront System YES 40 FI FRAMING MEMBERSPage-10 02-1001-02 | Effective Date: September 15, 2016

YES 40 FS/FI Storefront System YES 40 FI WIND LOAD CHARTSDEFLECTION CRITERIA: AAMA TIR-A11 - L/175 or L/240 + 1/4\" (6.4mm) - FOR SPANS GREATER THAN 13'-6\" (4.1m) BUT LESS THAN 40'-0\" (12.2m) CODES AND SPECIFICATIONS MAY VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4\" (19.1mm)ALLOWABLE WIND LOAD STRESS YKK AP tested standard. Contact YKK AP for more information.These charts include unbraced length analysis and are based off at least one horizontal being placed at the midpoint of the span. For otherapplications, please contact YKK AP engineers at 1-866-955-2732. 14 E9-1313 / E9-1012 E9-1313 / E9-1012 / E1-0166 V A 18 E 13 B Ixx=2.584 in4 V R C (107.55 cm4) E 17 T 12 D R 16 I T 11 I 15 C C A 10 A 14 L L 13 9 Ixx=5.385 in4 H 12 A H (224.16 cm4) 11 B E8 E 10 C I7 I D G G H6 H9 T T 5 8(FT) (FT) 23 45 6 7 A=15 PSF (720 Pa) 234 567VERTICAL SPACING (FT) B=20 PSF (960 Pa) VERTICAL SPACING (FT) C=30 PSF (1440 Pa) D=40 PSF (1920 Pa)Effective Date: September 15, 2016 | 02-1001-02 Page-11

YES 40 FS/FI Storefront System YES 4D0EFAIDDLEOAADDLOCHAADRCTHART 12 E9-1316 O P 11 A E 10 B N9 I N8 G7 H6 E5 I4 G H3 T2 (FT) 1 34 56 7 OPENING WIDTH (FT) A = Setting Blocks at 1/8 Point Locations B = Setting Blocks at 1/4 Point Locations Note: Dead load requirements are based upon a maximum deflection of 1/8\" (3.2mm) at the center of the horizontal.Page-12 02-1001-02 | Effective Date: September 15, 2016

YES 45 FS/FI


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook