Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore r_00001_ElKitap_TRready

r_00001_ElKitap_TRready

Published by Perihan Tekeli, 2023-07-10 12:21:21

Description: r_00001_ElKitap_TRready

Search

Read the Text Version

["\u015eekil 29. Tam boy rayl\u0131 profil konstr\u00fcksiyonda panellerin montaj\u0131 d) Kiremit \u00c7at\u0131 \u00dczerine Montaj Sistemleri Kiremit \u00e7at\u0131 sistemlerinde profiller ah\u015fap \u00e7at\u0131 profillere monte edilmektedir (\u015eekil 30). Ah\u015faba montaj i\u00e7in geli\u015ftirilmi\u015f \u00f6zel profiller ve ba\u011flant\u0131 elemanlar\u0131 kullan\u0131lmas\u0131 gerekmektedir. Montaj elemanlar\u0131n\u0131n kati suretle kiremitlere y\u00fck bindirmemesi gerekmektedir. \u015eekil 30. Kiremit \u00e7at\u0131 konstr\u00fcksiyon montaj\u0131 \u00f6rne\u011fi MOD\u00dcL 4 - 21","Montaja ba\u015flanmadan \u00f6nce daha \u00f6nceki b\u00f6l\u00fcmlerde belirtilen g\u00fcvenlik talimatlar\u0131na uyulmas\u0131, i\u015f g\u00fcvenli\u011fi i\u00e7in KKD (Ki\u015fisel koruyucu donan\u0131m) kullan\u0131m\u0131na dikkat edilmesi gerekmektedir. Montajda kullan\u0131lacak ba\u015fl\u0131ca sistem bile\u015fenleri Tablo 2\u2019de verilmektedir. Tablo 2. Kiremit \u00e7at\u0131 \u00fczerine montajda kullan\u0131lacak sistem bile\u015fenleri Montaj Raylar\u0131 Farkl\u0131 y\u00fckseklik se\u00e7ene\u011fi ile farkl\u0131 b\u00f6lgelere g\u00f6re uygulama yap\u0131labilir. Hammadde: Al\u00fcminyum EN-AW 6063 T66 Montaj Vidalar\u0131 Kiremit alt\u0131 OSB veya a\u015f\u0131\u011fa uygun boyda olmal\u0131d\u0131r. Hammadde: C4 korozyon dayan\u0131ml\u0131 \/ Bimetal Montaj Kancas\u0131 Kiremite zarar vermemelidir. Hammadde: Paslanmaz olmal\u0131d\u0131r. Orta ve Kenar Kelep\u00e7e Somun ve yayl\u0131 set halinde \u00f6n montaj\u0131 yap\u0131lm\u0131\u015f sevk edilir. Ara Ba\u011flant\u0131 Par\u00e7as\u0131 Uzun dizilerde raylar aras\u0131 ba\u011flant\u0131 par\u00e7as\u0131d\u0131r. Ak\u0131ll\u0131 vida ile montaj yap\u0131l\u0131r. Hammadde: Al\u00fcminyum EN-AW 6063 T66 MOD\u00dcL 4 - 22","\u015eekil 31\u2019de Kiremit \u00e7at\u0131 \u00fczerine montaj \u00f6rne\u011fi g\u00f6sterilmektedir. Montaj detay\u0131 \u015eekil 32\u2019de g\u00f6r\u00fclmektedir. K\u0131saca montaj a\u015famalar\u0131: 1 A\u015f\u0131klar\u0131n yerleri ve panel yerle\u015fimi kontrol edildikten sonra kancan\u0131n (1) yerle\u015ftirilece\u011fi yerler belirlenir. 2 Kancan\u0131n (1) yerle\u015ftirilece\u011fi k\u0131s\u0131mdaki kiremit kald\u0131r\u0131l\u0131r. 3 Kanca a\u015f\u0131k\/OSB \u00fczerine yerle\u015ftirilir ve 3 adet Ah\u015fap\/Trapez vidas\u0131 (2) ile a\u015f\u0131k\/OSB\u2019ye montaj\u0131 yap\u0131l\u0131r. 4 Y\u00fckselti farkl\u0131l\u0131\u011f\u0131 olu\u015fmamas\u0131 i\u00e7in; kald\u0131r\u0131lan kiremitin alt k\u0131sm\u0131 kancaya (1) uygun olacak \u015fekilde t\u0131ra\u015flan\u0131r ve kiremit yerine yerle\u015ftirilir. 5 Kancalar\u0131n (1) montaj\u0131 tamamland\u0131ktan sonra, Raylar (3), kancalar\u0131n (1) \u00fczerine yerle\u015ftirilir ve sivri u\u00e7lu inbus c\u0131vatalar ile sabitlenir. 6 Raylar (3) ara ba\u011flant\u0131 par\u00e7as\u0131 ile ba\u011flan\u0131r. Ara ba\u011flant\u0131 par\u00e7alar\u0131 iki ray\u0131n i\u00e7ine girecek \u015fekilde yerle\u015ftirilip 4 adet ak\u0131ll\u0131 vida ile sabitlenir. 7 Panel tutucular (4), \u00fcst s\u0131ra raylara (3) yerle\u015ftirilir. 8 Paneller raylara (3) oturtulduktan sonra panel tutucularda (4) bulunan inbus c\u0131vata 14-17 Nm tork ile s\u0131k\u0131larak panel montaj\u0131 tamamlan\u0131r. \u015eekil 31. Kiremit \u00e7at\u0131 \u00fczerine konstr\u00fcksiyon montaj\u0131 ve sistem bile\u015fenleri \u015eekil 32. Kiremit \u00e7at\u0131 \u00fczerine montaj detaylar\u0131 MOD\u00dcL 4 - 23","Ray ara ba\u011flant\u0131s\u0131 \u015eekil 33\u2019de g\u00f6sterildi\u011fi gibi yap\u0131l\u0131r. Uzun dize tasar\u0131mlar\u0131nda genle\u015fme kaynakl\u0131 tek tarafl\u0131 ba\u011flant\u0131 sa\u011flan\u0131r. \u015eekil 33. Ray ara ba\u011flant\u0131s\u0131 e) S\u0131k\u0131\u015ft\u0131rmal\u0131 Tip Uygulamalar (Kenet \u00c7at\u0131 Sistemleri) Tek kat ve \u00e7ift kat ray olara, kenete dik veya kenete yatay y\u00f6nde uygulanabilir. Di\u011fer e\u011fimli \u00e7at\u0131 montajlar\u0131ndan farkl\u0131 olarak \u00f6zel tasarlanm\u0131\u015f BAP\/BUP aparatlar\u0131 sayesinde kolay ve \u00f6m\u00fcrl\u00fck kurulum ger\u00e7ekle\u015ftirilir. Di\u011fer montaj tiplerinden farkl\u0131 olarak kullan\u0131lan aparatlara ili\u015fkin detaylar Tablo 3\u2019te verilmi\u015ftir. Tablo 3. S\u0131k\u0131\u015ft\u0131rmal\u0131 (Kenet) tip montajda kullan\u0131lan sistem bile\u015fenleri Montaj Aparat\u0131(ISOKEN) Yatay ve dikey y\u00f6nde kullan\u0131labilir T\u00fcm ba\u011flant\u0131 elemanlar\u0131 paslanmaz olmal\u0131d\u0131r. BAP\/BUP Aparat\u0131. Kenet aparat\u0131 ve ISOBEAM raylar\u0131n aras\u0131nda kullan\u0131l\u0131r. \u0130lave olarak ayar imkan\u0131 sunar. Ba\u011flant\u0131lar \u015eekil 34 ve \u015eekil 35\u2019de g\u00f6sterildi\u011fi bi\u00e7imde yap\u0131l\u0131r. S\u0131kma tork de\u011ferleri i\u00e7in montaj k\u0131lavuzuna bak\u0131lmal\u0131d\u0131r. MOD\u00dcL 4 - 24","\u015eekil 34. S\u0131k\u0131\u015ft\u0131rmal\u0131 (Kenet) tip montajda kullan\u0131lan sistem bile\u015fenlerinin uygulama detay\u0131 \u015eekil 35. Kenet \u00e7at\u0131 ray ve kenet tutucu profil montaj\u0131 MOD\u00dcL 4 - 25","f) Shingle Kapl\u0131 \u00c7at\u0131larda Montaj Shingle kapl\u0131 \u00e7at\u0131larda kenet \u00e7at\u0131lara benzer \u015fekilde BUP aparatlar\u0131 kullan\u0131larak ba\u011flant\u0131 yap\u0131lmaktad\u0131r. Shingle \u00e7at\u0131 ray \u00e7at\u0131 aras\u0131 ba\u011flant\u0131 eleman\u0131 \u015eekil 36\u2019da g\u00f6sterilmektedir. \u015eekil 36. Shingle \u00e7at\u0131 ray \u00e7at\u0131 aras\u0131 ba\u011flant\u0131 eleman\u0131 Shingle \u00fczerine yerle\u015ftirilen plakalar \u00fczerine BUP aparatlar\u0131 \u015eekil 37\u2019de g\u00f6sterildi\u011fi gibi yerle\u015ftirilir. \u015eekil 37. Shingle \u00e7at\u0131 ray \u00e7at\u0131 aras\u0131 ba\u011flant\u0131 eleman\u0131 montaj\u0131 Shingle kapl\u0131 \u00e7at\u0131lar \u00fczerine montaj\u0131n nihai sistem g\u00f6r\u00fcn\u00fcm\u00fc \u015eekil 38\u2019deki gibidir. MOD\u00dcL 4 - 26","\u015eekil 38. Shingle \u00e7at\u0131 konstr\u00fcksiyon montaj\u0131 g) Onduline \u00c7at\u0131 Montaj Sistemi Shingle ve kenet \u00e7at\u0131lara benzer \u015fekilde BUP aparatlar\u0131 kullan\u0131larak ba\u011flant\u0131 yap\u0131lmaktad\u0131r. Onduline \u00fczerine yerle\u015ftirilen plakalar \u00fczerine BUP aparatlar\u0131 yerle\u015ftirilir. Di\u011fer montaj tiplerinden farkl\u0131 olarak kullan\u0131lan aparatlara ili\u015fkin \u00f6zellikler Tablo 4\u2019te, montaj detaylar\u0131 da \u015eekil 39\u2019da g\u00f6sterilmektedir. Tablo 4. Onduline \u00e7at\u0131 montaj sistemi temel bile\u015feni Di\u015fli Contal\u0131 A\u015f\u0131k Saplamas\u0131 Contas\u0131 ile birlikte sevk edilir Prefabrik, \u00c7elik ve Ah\u015fap a\u015f\u0131k saplamalar\u0131 mevcuttur. Hammadde: Paslanmaz A2\/70 \u015eekil 39. Onduline konstr\u00fcksiyon montaj\u0131 ve ray \u00e7at\u0131 aras\u0131 ba\u011flant\u0131 eleman\u0131 MOD\u00dcL 4 - 27","1.4. KONSTR\u00dcKS\u0130YON MONTAJ \u00d6RNEKLER\u0130 VE A\u015eAMALARI 1.4.1. \u00c7ift Kolon Yer Sistemi Konstr\u00fcksiyon Montaj\u0131 ve A\u015famalar\u0131 Yer sistemlerinde kullan\u0131lan konstr\u00fcksiyon yap\u0131s\u0131n\u0131n bile\u015fenleri genel anlamda \u015eekil 40\u2019daki gibidir. P1: \u00d6n Ayak \/ \u00d6n Kolon P2: Arka Ayak \/Arka Kolon P3: Kiri\u015f P4: A\u015f\u0131k P6: A\u015f\u0131k Ba\u011flant\u0131s\u0131 P7: R\u00fczgarl\u0131k P8: Payanda \u015eekil 40. Yer sistemlerinde kullan\u0131lan konstr\u00fcksiyon yap\u0131s\u0131n\u0131n bile\u015fenleri a) Malzemelerin Haz\u0131rlanmas\u0131 \u2022 Malzemelerin bo\u015falt\u0131lmas\u0131 s\u0131ras\u0131nda elemanlar ve bunlar\u0131n say\u0131s\u0131 kontrol edilmelidir. Herhangi bir hata tespit edilirse, malzemenin sahaya ula\u015fmas\u0131ndan hemen sonra \u00fcreticiye yaz\u0131l\u0131 bildirimde bulunulmal\u0131d\u0131r. \u2022 Elemanlar EN-ISO 1461'e g\u00f6re s\u0131cak dald\u0131rma galvanizlidir. Galvanizli elemanlar kesinlikle kaynakland\u0131r\u0131lmamal\u0131, kesilmemeli ve delinmemelidir. \u2022 \u00c7arpma s\u0131ras\u0131nda hasar g\u00f6ren elemanlar\u0131n onar\u0131m\u0131 EN-ISO 1461\u2019e g\u00f6re \u00e7inko boya ile yap\u0131lmal\u0131d\u0131r. \u2022 C\u0131vatalar tork anahtarlar\u0131 ile tak\u0131lmal\u0131d\u0131r. b) Sahan\u0131n Haz\u0131rlanmas\u0131 Solar panellerin ve dolay\u0131s\u0131yla kiri\u015f ve a\u015f\u0131klar\u0131n seviyelerinin e\u015f de\u011ferde olmas\u0131 kolonlar\u0131n \u00fcst noktalar\u0131n\u0131n ayn\u0131 seviyede olmas\u0131na ba\u011fl\u0131d\u0131r. \u2022 Kolonlar\u0131n \u00e7ak\u0131m\u0131ndan \u00f6nce in\u015faata uygun olmayan zemin (nebati toprak vb.) s\u0131yr\u0131lmal\u0131 ve zemin tesviye edilmelidir. \u2022 Zeminin e\u011fimi ile ilgili s\u0131n\u0131rlar ve toleranslar a\u015fa\u011f\u0131da verilmi\u015ftir. \u2022 G\u00f6mme derinli\u011fi tolerans\u0131 genellikle \u00b1 50 mm olarak belirlenmektedir (\u015eekil 41). Kolonlar\u0131n \u00fcst noktalar\u0131n\u0131n hizada olmas\u0131 durumunda zeminin bu de\u011ferlerden fazla de\u011fi\u015fim g\u00f6stermesi zeminin yeterince iyi tesviye edilmedi\u011fi anlam\u0131na gelmektedir. \u00c7ak\u0131m i\u015flemine ba\u015flamadan \u00f6nce zemin tesviye edilmeli ve zemin d\u00fczetilmeden \u00e7ak\u0131m i\u015flemine ba\u015flanmamal\u0131d\u0131r. MOD\u00dcL 4 - 28","\u015eekil 41. Yer Sistemlerinde kolonlar\u0131n araziye \u00e7ak\u0131m mesafesi c) G\u00fcvenlik Talimatlar\u0131 Kurulum s\u0131ras\u0131nda personel t\u00fcm b\u00f6lgesel g\u00fcvenlik gerekliliklerini takip etmelidir. T\u00fcm \u015fantiyelerde oldu\u011fu gibi i\u015fyeri g\u00fcvenli\u011fi de \u00f6nceliklidir. \u015eekil 42\u2019de g\u00f6sterilen PPE (Ki\u015fisel Koruyucu Ekipman) \u00f6\u011felerini giymek ve tan\u0131tmak tavsiye edilir. Tablo 5\u2019te ise montajda kullan\u0131lmas\u0131 gerekli el aletleri \u00f6zetlenmi\u015ftir. \u015eekil 42. Montajda kullan\u0131lmas\u0131 gerekli i\u015f g\u00fcvenli\u011fi ekipmanlar\u0131 MOD\u00dcL 4 - 29","KOD Tablo 5. Montajda kullan\u0131lmas\u0131 gerekli el aletleri A\u00c7IKLAMA JIG4 \u015eEK\u0130L JIG5 A\u015f\u0131klardan \u00e7\u0131k\u0131nt\u0131 aparat\u0131 T1 T2 A\u015f\u0131k mesafesi ayarlay\u0131c\u0131 T3 T4 Rotasyon lazeri T5 \u015eerit metre T6 Su terazisi \u0130p A\u00e7\u0131\u00f6l\u00e7er Torkmetre Kumpas MOD\u00dcL 4 - 30","d) \u0130lk ve Son Ayaklar\u0131n \u00c7ak\u0131lmas\u0131 ve G\u00f6nyeye Al\u0131nmas\u0131 \u00d8 Harita M\u00fchendisinin i\u015faretledi\u011fi birinci sehpan\u0131n P1 ve P2 ayak\/kolon yerlerine demir \u00e7ubuk \u00e7ak\u0131l\u0131r (\u015eekil 43). \u00d6n ve arka ayak yerlerine \u00e7akt\u0131\u011f\u0131 \u00e7ubuklar\u0131n 20cm d\u0131\u015f\u0131na demir \u00e7ubuk \u00e7ak\u0131l\u0131r. \u015eekil 43. \u0130lk ve son kolon yerlerinin belirlenmesi ve \u00e7ak\u0131m\u0131 \u00d8 Yerden 50 cm y\u00fckseklikten ip \u00e7ekilir. \u00d6n ve arka ayak ara mesafeleri (Statik ve Mekanik projede belirtilen de\u011ferlerde) ip \u00fczerinde i\u015faretlenir (\u015eekil 44). \u015eekil 44. Ara ayak yerlerinin belirlenmesi ve \u00e7ak\u0131m\u0131 \u00d8 \u015eekil 45\u2019de verildi\u011fi gibi \u00f6n ayaklar\u0131n \u00fcsten markalama \u00f6l\u00e7\u00fcs\u00fc Denklem (1)\u2019de verildi\u011fi gibi hesaplan\u0131r. \u00d6n ayaklar\u0131n markalama = Zemin \u00fcst\u00fc - \u0130p y\u00fcksekli\u011fi (50 (1) \u00f6l\u00e7\u00fcs\u00fc \u00f6l\u00e7\u00fcs\u00fc (cm) cm) \u00d8 Hattaki b\u00fct\u00fcn \u00f6n ayaklar bu \u00f6l\u00e7\u00fcye g\u00f6re i\u015faretlenir ve i\u015faretli yere kadar \u00e7ak\u0131l\u0131r (\u015eekil 45). \u015eekil 45. Arka ayak \u00e7ak\u0131m mesafesi MOD\u00dcL 4 - 31","\u00d8 Rotasyon lazeri ile \u00f6n ayaklar i\u00e7in \u00e7ekilen ipe arka ayaklar i\u00e7in \u00e7ekilen ip ayn\u0131 d\u00fczleme getirilir (\u015eekil 46). \u015eekil 46. \u00d6n ve arka ayak ayarlama i\u015flemi \u00d8 \u00d6n ve arka ayak yerleri belirlendikten sonra \u00e7ak\u0131m i\u015flemine ge\u00e7ilir (\u015eekil 47). \u015eekil 47. Sehpa \u00e7ak\u0131mlar\u0131n\u0131n yap\u0131lmas\u0131 \u00d8 Ayaklar \u00e7ak\u0131l\u0131rken; y\u00f6n e\u011fiklikleri su terazisi ile \u015eekil 48\u2019de g\u00f6sterilen tan\u0131mlanm\u0131\u015f toleranslara uygun \u015fekilde kontrol edilir. Uygunsuz durumda tekrar ayarlama yap\u0131larak uygun hale getirilir. \u015eekil 48. Ayak e\u011fiklikleri tan\u0131mlanm\u0131\u015f toleranslar\u0131 MOD\u00dcL 4 - 32","\u00d8 \u00d6n ve arka ayak \u00e7ak\u0131ld\u0131ktan sonra JIG2 aparat\u0131 ile ayaklar\u0131n birbirine g\u00f6re ayn\u0131 eksende oldu\u011fu kontrol edilir (\u015eekil 49). Eksen fark\u0131 2,5 cm\u2019den az olmal\u0131d\u0131r. Uygun de\u011fil ise \u00f6n ayak \u00e7akma makinesi ile d\u00f6nd\u00fcr\u00fclerek kabul edilebilir de\u011ferlere getirilir. Uygunsuz durumda ayaklar d\u00f6nd\u00fcr\u00fclerek ayaklar \u00e7\u0131kar\u0131l\u0131r. \u015eekil 49. Eksen kontrol\u00fc e) Kiri\u015f Montaj\u0131 \u00d8 \u015eekil 50\u2019de montaj detay\u0131 verilen ilk ve son ayaklara kiri\u015fler \u015eekil 51\u2019de belirtilen de\u011ferlere uygun olarak monte edilir. De\u011ferler proje \u00f6zelliklerine g\u00f6re de\u011fi\u015febilir. \u015eekil 50. Kiri\u015f montaj\u0131 detay\u0131 MOD\u00dcL 4 - 33","\u015eekil 51. Kiri\u015f montaj\u0131 \u00d8 A-A noktalar\u0131 aras\u0131na ip \u00e7ekerek JIG3 yard\u0131m\u0131 ile iple kiri\u015f aras\u0131 90\u00b0 olmas\u0131 sa\u011flan\u0131r B-B noktalar\u0131 aras\u0131na da ip \u00e7ekilir (\u015eekil 52). \u015eekil 52. \u0130lk ve son kiri\u015f montaj\u0131 simetri ayarlamas\u0131 \u00d8 Orta kiri\u015fler \u015eekil 53\u2019de g\u00f6r\u00fcld\u00fc\u011f\u00fc gibi ip1 ve ip2 aras\u0131na hizalanarak montaj\u0131 yap\u0131l\u0131r. MOD\u00dcL 4 - 34","\u015eekil 53. Orta kiri\u015flerin montaj\u0131 f) A\u015f\u0131k Montaj\u0131 \u015eekil 54\u2019te detay\u0131 verilen a\u015f\u0131k montaj\u0131nda kiri\u015fin a\u015f\u0131ktan \u00e7\u0131k\u0131nt\u0131s\u0131 JIG4 aparat\u0131 ile ayarlanarak ilk s\u0131radaki a\u015f\u0131klar\u0131n montaj\u0131 \u015eekil 55\u2019de g\u00f6r\u00fcld\u00fc\u011f\u00fc gibi yap\u0131l\u0131r. \u015eekil 54. A\u015f\u0131k montaj\u0131 detay\u0131 MOD\u00dcL 4 - 35","\u015eekil 55. A\u015f\u0131k \u00e7\u0131k\u0131nt\u0131s\u0131 detay\u0131 \u00d8 Son s\u0131radaki a\u015f\u0131klar\u0131n \u00f6n montaj\u0131 yap\u0131larak diyagonal \u00f6l\u00e7\u00fcmleri kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r. g) Diyagonal Kontrol A\u015f\u0131klar\u0131n panel ba\u011flant\u0131 deliklerinden metre ile diyagonal \u00f6l\u00e7\u00fcm yap\u0131l\u0131r. Diyagonal kontrolde al\u0131nan \u00f6l\u00e7\u00fcmler \u015eekil 56\u2019da gergi aparat\u0131 kullan\u0131m\u0131 ise \u015eekil 57\u2019de g\u00f6sterilmektedir. \u015eekil 56. Diyagonal Kontrol MOD\u00dcL 4 - 36","\u015eekil 57. Diyagonal kontrolde gergi aparat\u0131 kullan\u0131m\u0131 E\u011fer A> B ise \u015eekil 57\u2019de g\u00f6r\u00fcld\u00fc\u011f\u00fc gibi gergi aparat\u0131 ba\u011flan\u0131r. Tel (A-B) \/ 2 kadar geri \u00e7ekilir ve ba\u011flant\u0131 c\u0131vatalar\u0131 s\u0131k\u0131larak montaj tamamlan\u0131r. \u0130lk a\u015f\u0131k montaj\u0131ndan sonra JIG5 yard\u0131m\u0131yla di\u011fer a\u015f\u0131klar\u0131n paralelli\u011fi sa\u011flan\u0131r (\u015eekil 58). \u015eekil 58. Diyagonal kontrolle ayar yap\u0131lmas\u0131 h) Panellerin Konstr\u00fcksiyona Montaj\u0131 Panellerin konstr\u00fcksiyona ba\u011flant\u0131 detaylar\u0131 \u015eekil 59 ve \u015eekil 60\u2019da g\u00f6sterilmektedir. MOD\u00dcL 4 - 37","\u015eekil 59. Panel konstr\u00fcksiyon ba\u011flant\u0131lar\u0131 \u00d8 G\u00fcne\u015f panelleri \u00f6nce ilk s\u0131ra dikey olarak ip yard\u0131m\u0131 ile hizalan\u0131r ve sehpan\u0131n en son alt paneli ba\u011flanarak ip \u00e7ekilerek hizalan\u0131r. \u00d8 En alt s\u0131ra \u00e7ekilen iplere hizalanarak dizilir ve \u00fcst s\u0131ralara do\u011fru bu hiza takip edilerek dizilir. \u00d8 G\u00fcne\u015f panelleri klempler ile a\u015f\u0131klara ba\u011flan\u0131r. \u00d8 G\u00fcne\u015f panel ara ba\u011flant\u0131lar\u0131nda H klemp, kenar ba\u011flant\u0131lar\u0131nda Z klemp kullan\u0131l\u0131r. \u00d8 Klempler monte edilmeden \u00f6nce a\u015f\u0131klar aras\u0131ndaki mesafe kontrol edilmelidir. A\u015f\u0131klar aras\u0131nda yer alan mesafenin toleranslar\u0131n d\u0131\u015f\u0131nda kalmas\u0131 durumunda panellerin klempler aras\u0131na yerle\u015fmesi zorla\u015facakt\u0131r. A\u015f\u0131klar aras\u0131nda yer alan mesafe a\u015f\u0131k-kiri\u015f ba\u011flant\u0131s\u0131 aras\u0131nda yer alan slotlar taraf\u0131ndan ayarlanabilir. \u00d8 Paneller aras\u0131nda yer alan mesafe teknik resimlerde belirtildi\u011fi kadar olmal\u0131d\u0131r. \u00d8 Paneller aras\u0131 mesafenin belirtilen de\u011ferlerin d\u0131\u015f\u0131na \u00e7\u0131kmas\u0131, panellerin a\u015f\u0131k \u00fczerine yerle\u015fememesine veya klemplerin uygun mesafelerden panelleri sabitleyememesine neden olur \u00d8 Orta klempler (H) iki FV panel aras\u0131na yerle\u015ftirilmelidir. \u00d8 Son klemp (Z), art\u0131k kom\u015fu FV panelin olmad\u0131\u011f\u0131 FV panellerin ucuna yerle\u015ftirilmelidir. \u00d8 Klemplerin her iki tipi i\u00e7in de sabitleme i\u00e7in genellikle M8 c\u0131vata setleri kullan\u0131lmal\u0131d\u0131r. \u00dcr\u00fcn \u00e7e\u015fidine ba\u011fl\u0131 olarak de\u011fi\u015fkenlik g\u00f6sterebilir. \u00d8 Konstr\u00fcksiyon tipine g\u00f6re ba\u011flant\u0131 elemanlar\u0131 de\u011fi\u015fkenlik g\u00f6sterebilir. Ba\u015fl\u0131ca ba\u011flant\u0131 elemanlar\u0131 Tablo 6\u2019da \u00f6zetlenmi\u015ftir. MOD\u00dcL 4 - 38","\u015eekil 60. H ve Z klempler ile panellerin konstr\u00fcksiyona montaj\u0131 Tablo 6. Montaj ba\u011flant\u0131 elemanlar\u0131 BA\u011eLANTI T\u0130P\u0130 \u00d6L\u00c7\u00dcLER STANDART SIKILAMA ELEMANI TORK DE\u011eER\u0130 C\u0130VATA M12x30mm DIN 933 40 Nm M16x40mm C\u0130VATA M8x40mm DIN 912 8 Nm SOMUN M8 M12 DIN 934 M16 PUL M8 M12 M16 DIN 125 RONDELA M8 M12 M16 DIN 127 Montaj elemanlar\u0131n\u0131n izin verilen montaj toleranslar\u0131 Tablo 7\u2019de listelenmi\u015ftir. MOD\u00dcL 4 - 39","Tablo 7. Montaj elemanlar\u0131n\u0131n montaj toleranslar\u0131 No \u00d6l\u00e7\u00fcm\/ \u00d6l\u00e7\u00fcm Noktas\u0131 Tolerans Referans Kod \u00d6l\u00e7\u00fc Aleti P1 (+)100 2.1 T1 \u015eerit Metre Yerden y\u00fckseklik (-)50 1 kontrol\u00fc (ilk ve son (+)100 (-)150 ayak) P2 2 A\u00e7\u0131 kontrol\u00fc do\u011fu- P1 2.1 T2 Su terazisi bat\u0131 P2 \u00b12\u00b0 T2 Su terazisi P1 toprak s\u0131n\u0131f\u0131 2.1 JIG2 Ayak hizalama (soil class) 4 2.1.1 JIG3 Diklik kontrol\u00fc 3 A\u00e7\u0131 kontrol\u00fc kuzey- \u00b10,8\u00b0 T3 \u0130p toprak s\u0131n\u0131f\u0131 g\u00fcney P2 (soil class) 5 \u00b11,3\u00b0 4 Eksen kontrol\u00fc P1 5 Diklik kontrol\u00fc P2 max 25,88 mm P3 P3 2.2 \u00b10\u00b0 6 A\u00e7\u0131 kontrol\u00fc P3 \u00b10\u00b0 2.2 T4 A\u00e7\u0131\u00f6l\u00e7er 7 A\u015f\u0131klardan \u00e7\u0131k\u0131nt\u0131 P3- P4 \u00b18 mm 2.4.1 JIG4 A\u015f\u0131klardan kontrol\u00fc 2.5 \u00e7\u0131k\u0131nt\u0131 Panel 8 Diyagonal kontrol ba\u011flant\u0131 \u00b110 mm T1 \u015eerit Metre delikleri JIG5 A\u015f\u0131k mesafesi 9 A\u015f\u0131klar ara kontrol\u00fc P4 \u00b18 mm 2.5 JIG5 A\u015f\u0131k mesafesi 1.4.2. D\u00fcz \u00c7at\u0131larda Konstr\u00fcksiyon Montaj\u0131 ve A\u015famalar\u0131 a) G\u00fcvenlik Talimatlar\u0131 \u2022 Ulusal ve sahaya \u00f6zel bina y\u00f6netmelikleri, standartlar\u0131 ve \u00e7evre koruma y\u00f6netmeliklerine uyulmal\u0131d\u0131r. \u2022 \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile kaza \u00f6nleme y\u00f6netmelikleri, ilgili standartlar ve i\u015fveren mali mesuliyet sigortas\u0131 birli\u011finin y\u00f6netmelikleri dikkate al\u0131nmal\u0131d\u0131r. \u00d6zellikle \u015funlara dikkat edilmelidir: o G\u00fcvenlik k\u0131yafeti \u00f6zellikle koruyucu baret, i\u015f ayakkab\u0131s\u0131 ve eldiven giyilmelidir (\u015eekil 61). o Bir kaza durumunda h\u0131zl\u0131 yard\u0131m sa\u011flayabilmek i\u00e7in t\u00fcm montaj s\u00fcreci i\u00e7in iki ki\u015finin varl\u0131\u011f\u0131 esast\u0131r. MOD\u00dcL 4 - 40","\u2022 Mod\u00fcl \u00fcreticisinin montaj talimatlar\u0131na uyulmal\u0131d\u0131r. \u2022 Sistemin m\u00fcnferit par\u00e7alar\u0131 aras\u0131ndaki e\u015f potansiyel ba\u011flant\u0131, ilgili \u00fclkeye \u00f6zg\u00fc d\u00fczenlemelere g\u00f6re yap\u0131lmal\u0131d\u0131r. \u2022 T\u00fcm montaj s\u00fcresi boyunca, \u015fantiyede montaj talimatlar\u0131 uygulama \u00e7iziminin en az bir kopyas\u0131n\u0131n bulunmas\u0131 sa\u011flanmal\u0131d\u0131r. \u2022 Paslanmaz \u00e7elikten yap\u0131lm\u0131\u015f bile\u015fenler, farkl\u0131 korozyon direnci s\u0131n\u0131flar\u0131nda mevcuttur. \u2022 Her durumda, ilgili bina veya bile\u015fen i\u00e7in hangi korozyon y\u00fck\u00fcn\u00fcn beklendi\u011fi kontrol edilmelidir. Z600 kapl\u0131 \u00e7elik profiller belli bir s\u00fcre sonra stati\u011fi etkilemeyen k\u0131rm\u0131z\u0131 korozyon lekeleri g\u00f6sterebilir. \u2022 \u00c7at\u0131 kaplamas\u0131na zarar vermeden uygulanmal\u0131d\u0131r. \u015eekil 61. Montajda kullan\u0131lacak i\u015f g\u00fcvenli\u011fi ekipmanlar\u0131 MOD\u00dcL 4 - 41","b) Malzemelerin haz\u0131rlanmas\u0131 D\u00fcz \u00e7at\u0131 konstr\u00fcksiyonlar\u0131nda kullan\u0131lan ba\u015fl\u0131ca sistem bile\u015fenleri ve temel \u00f6zellikleri Tablo 8\u2019de \u00f6zetlenmi\u015ftir. Tablo 8. D\u00fcz \u00e7at\u0131 konstr\u00fcksiyonlar\u0131nda kullan\u0131lan ba\u015fl\u0131ca sistem bile\u015fenleri FBS FBS Ayak ile zemin ray\u0131 birbirine ge\u00e7meli yap\u0131da olacak \u015fekilde sabitlenir SBR Yap\u0131\u015fkanl\u0131 zemin koruyucu ile birlikte kullan\u0131l\u0131r. Hammadde: Al\u00fcminyum ENW 6063 T66 Y\u00fczey koruma SBR \u00c7at\u0131 kaplamas\u0131na daha iyi tutum sa\u011flamak ve \u00e7at\u0131 kaplamas\u0131na zarar vermemek i\u00e7in kullan\u0131l\u0131r. Membran \u00e7at\u0131lar i\u00e7in al\u00fcminyum alt taban\u0131 yap\u0131\u015fkanl\u0131d\u0131r. T\u00fcm membran tipleri ile kimyasal olarak uyumludur. Alev geciktirici (zor yanan)- DIN EN EN501-5'e g\u00f6re BROof (t1) s\u0131n\u0131\ufb02and\u0131rmas\u0131, DIN V ENV 1187 testine g\u00f6re tedarik edilebilir. Zemin Ray\u0131 (TFX) M8 paslanmaz \u00e7elik T ba\u015fl\u0131 c\u0131vatalar ile uyumludur Hammadde: Al\u00fcminyum ENW 6063 T66 \u00d6n Ayak (ISOFLAT FS.2) Vidas\u0131z birle\u015fim ile ray\u0131n \u00fczerine sabitlenir Hammadde: Al\u00fcminyum ENW 6063 T66 Arka Ayak (ISOFLAT BS.2) Herhangi bir vida olmadan TFX raya sabitlenir Hammadde: Al\u00fcminyum ENW 6063 T66 Arka R\u00fczgarl\u0131k (ISOFLAT RUA.2) 5.5x25 sivri u\u00e7lu vida ile kullan\u0131l\u0131r Hammadde ve Kaplama: Pregalvaniz Sac MOD\u00dcL 4 - 42","Tablo 8- Devam\u0131. D\u00fcz \u00e7at\u0131 konstr\u00fcksiyonlar\u0131nda kullan\u0131lan ba\u015fl\u0131ca sistem bile\u015fenleri Sonland\u0131rma Klempi (Z\/End Klemp) \u00d6zel patentli al\u00fcminyum somun ve yayl\u0131 set halinde \u00f6n montaj\u0131 yap\u0131lm\u0131\u015f sevk edilir. Universal kelep\u00e7eler 35- 45 mm y\u00fcksekli\u011findeki t\u00fcm \u00e7er\u00e7eveli FV mod\u00fclleriyle sorunsuz bir \u015fekilde monte edilebilir. Ray Ba\u011flant\u0131 Par\u00e7as\u0131 TFX raylar\u0131n\u0131n ba\u011flant\u0131s\u0131 i\u00e7in kullan\u0131l\u0131r M8 paslanmaz \u00e7elik c\u0131vata ve kare somun ile sabitlenir. Hammadde: Al\u00fcminyum ENW 6063 T66. Alyan Ba\u015fl\u0131 C\u0131vata & Kare Somun Boyut: M8x40 Kalite: Paslanmaz A2-70 XCLAMP Isobeam TFX1200 ray\u0131n\u0131n ana ray ile sabitlenmesi i\u00e7in kullan\u0131l\u0131r M8x20 T ba\u015fl\u0131 c\u0131vata ve M8 flan\u015fl\u0131 somun ile sabitlenir Hammadde: Al\u00fcminyum ENW 6063 T66 T Ba\u015fl\u0131 C\u0131vata & Flan\u015fl\u0131 Somun Boyut: M8 Kalite: Paslanmaz A2-70 Kapak TFX ray ile uyumlu kapakt\u0131r Tablo 9\u2019da panel destek par\u00e7alar\u0131, ba\u011flant\u0131 elemanlar\u0131, ba\u011flant\u0131 ara\u00e7lar\u0131 ve denge elemanlar\u0131 verilmi\u015ftir. MOD\u00dcL 4 - 43","Tablo 9. Montaj elemanlar\u0131 c) Montaj\u0131n Yap\u0131lmas\u0131 Montaj ba\u011flant\u0131 detaylar\u0131 \u015eekil 62\u2019de A-B-C-D olarak isimlendirilerek verilmi\u015ftir. \u015eekil 62. D\u00fcz \u00e7at\u0131 montaj\u0131 ba\u011flant\u0131 detaylar\u0131 \u015eekil 62\u2019de A olarak adland\u0131r\u0131lan \u00f6n ayak (Detay E) montaj\u0131n\u0131n ba\u011flant\u0131 detay\u0131 \u015eekil 63\u2019de g\u00f6sterilmektedir. \u015eekil 63. Detay A ve \u00f6n ayak montaj\u0131 MOD\u00dcL 4 - 44","\u015eekil 62\u2019de B olarak adland\u0131r\u0131lan arka ayak montaj\u0131n\u0131n ba\u011flant\u0131 detay\u0131 \u015eekil 64\u2019de g\u00f6sterilmektedir. \u015eekil 64. Detay B ve arka ayak montaj\u0131 \u015eekil 62\u2019de C olarak adland\u0131r\u0131lan arka ayak montaj\u0131n\u0131n ba\u011flant\u0131 detay\u0131 \u015eekil 65\u2019de g\u00f6sterilmektedir. \u015eekil 65. Detay C ve arka ayak montaj detay\u0131 \u015eekil 62\u2019de D olarak adland\u0131r\u0131lan klemp montaj\u0131n\u0131n ba\u011flant\u0131 detay\u0131 \u015eekil 66\u2019da g\u00f6sterilmektedir. MOD\u00dcL 4 - 45","\u015eekil 66. Klemp montaj detay\u0131 d) Mod\u00fcl Destek Par\u00e7alar\u0131 Montaj\u0131 \u00d8 FS2 \u00f6n ayak aparatlar\u0131n\u0131 (4.) kurulum \u00f6l\u00e7\u00fc tablosunda verilen \u00f6l\u00e7\u00fclere uygun olarak (50 mm) TFX ray\u0131n (3.) \u00fczerine g\u00fcne\u015f paneli e\u011fiminin do\u011frultusu ile \u00f6n ayak aparat\u0131n\u0131n e\u011fiminin do\u011frultusu ayn\u0131 olacak \u015fekilde ge\u00e7iriniz. \u00d8 BS2 arka ayak aparatlar\u0131n\u0131 (5.) g\u00fcne\u015f panelinin k\u0131sa kenar uzunlu\u011funa uygun olarak TFX ray\u0131n (3.) \u00fczerine g\u00fcne\u015f paneli e\u011fiminin do\u011frultusu ile arka ayak aparat\u0131n\u0131n e\u011fiminin do\u011frultusu ayn\u0131 olacak \u015fekilde ge\u00e7iriniz. \u00d8 FBS ayak aparatlar\u0131n\u0131 (1.) TFX ray\u0131n (3.) alt\u0131nda ki kanala ge\u00e7irerek \u00f6n ve arka ayak aparatlar\u0131 ile ayn\u0131 konum getirecek \u015fekilde monte ediniz. Her bir \u00f6n (4.) ve arka ayak (5.) aparat\u0131 i\u00e7in birer FBS ayak aparat\u0131 kullan\u0131lacakt\u0131r. \u00d8 Y\u00fczey koruma SBR (2.) par\u00e7as\u0131n\u0131 her bir FBS (1.) ayak aparat\u0131n\u0131n alt\u0131na gelecek \u015fekilde yerle\u015ftiriniz. Kurulum \u00f6l\u00e7\u00fcm tablosu ve montaj plan\u0131 \u015eekil 67\u2019de verilmi\u015ftir. \u015eekil 67. Kurulum \u00f6l\u00e7\u00fcm tablosu ve montaj plan\u0131 MOD\u00dcL 4 - 46","e) Ba\u011flant\u0131 Bile\u015fenlerinin Montaj\u0131 Ba\u011flant\u0131 bile\u015fenlerinin montaj detay\u0131 \u015eekil 68\u2019de g\u00f6sterilmektedir. \u015eekil 68. Ba\u011flant\u0131 bile\u015fenlerinin g\u00f6sterimi \u00d8 Alyan ba\u015fl\u0131 c\u0131vata ve kare somunu (9.) TFX konekt\u00f6r (8.) aparat\u0131na monte edip, TFX raylar\u0131 (3.) konekt\u00f6r\u00fcn sa\u011f ve solundan TFX konekt\u00f6r (8.) i\u00e7ine ge\u00e7iriniz ve alyan ba\u015fl\u0131 c\u0131vata (M8x40) ve kare somunu (M8) s\u0131karak montaj\u0131 tamamlay\u0131n\u0131z. \u00d8 Xclamp aparat\u0131n\u0131 (7.) TFX balast destek ray\u0131n\u0131n (3.) uygun kenar\u0131na g\u00f6rselde g\u00f6r\u00fcld\u00fc\u011f\u00fc gibi ge\u00e7iriniz ve T ba\u015fl\u0131 c\u0131vata ve flan\u015fl\u0131 somun (M8) (11.) ile s\u0131karak balast destek ray\u0131 montajlar\u0131n\u0131 tamamlay\u0131n\u0131z. Balast destek ray\u0131n\u0131n arka deste\u011fe yaslanmad\u0131\u011f\u0131 durumlarda ray\u0131n \u00e7ift taraf\u0131ndan Xclamp aparat\u0131 (10.) ile sabitleme yap\u0131n\u0131z. \u00d8 Easy Clamp panel tutucular\u0131 (7.) FS2 (4.) ve BS2 (5.) \u00f6n ve arka ayaklar\u0131 \u00fczerine tak\u0131l\u0131r. Paneller F S2 (4.) ve BS2 (5.) \u00fczerine yerle\u015ftirildikten sonra Easy Clamp kelep\u00e7elerde (7.) bulunan imbus c\u0131vata ile 14-17 Nm tork ile s\u0131k\u0131larak panel montaj\u0131 tamamlan\u0131r. f) Sabitleme Se\u00e7enekleri Hesaplamalar sonucunda panel ba\u015f\u0131na gereken a\u011f\u0131rl\u0131klar\u0131n miktar\u0131na g\u00f6re balast sabitleme sistemi de\u011fi\u015fiklik g\u00f6sterebilir. \u00d8 Panel ba\u015f\u0131 50 kg\u2019a kadar A opsiyonu kullan\u0131l\u0131r (\u015eekil 69). A opsiyonunda balastlar raylar\u0131n \u00fczerine yerle\u015ftirilir. \u00d8 Panel ba\u015f\u0131 gereken a\u011f\u0131rl\u0131k miktar\u0131n\u0131n 50 kg\u2019dan fazla oldu\u011fu durumlarda B opsiyonu kullan\u0131l\u0131r (\u015eekil 70). B opsiyonu montaj\u0131 Xclamp (10.) ile sabitlenmi\u015f TFX raylar\u0131n (3.) \u00fczerine yerle\u015ftirilerek yap\u0131l\u0131r. MOD\u00dcL 4 - 47","\u015eekil 69. Balast ile sabitleme A se\u00e7ene\u011fi \u015eekil 70. Balast ile sabitleme B se\u00e7ene\u011fi \u00d8 R\u00fczgarl\u0131k bile\u015feni (6.) arka destek aparat\u0131 BS2 (5.) \u00fczerine yerle\u015ftirilir ve \u00d85.5x25 vida kullan\u0131larak sabitlenir (\u015eekil 71). \u015eekil 71. R\u00fczgarl\u0131k montaj\u0131 MOD\u00dcL 4 - 48","KONU 2 FOTOVOLTA\u0130K PANELLER\u0130N MEKAN\u0130K MONTAJI 2.1. MONTAJ \u00d6NCES\u0130 GENEL B\u0130LG\u0130LER VE UYARILAR \u2022 Mod\u00fcller, g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131na veya di\u011fer \u0131\u015f\u0131k kaynaklar\u0131na maruz kald\u0131klar\u0131nda DC elektrik enerjisi \u00fcretir. Ba\u011flant\u0131 kutusu gibi mod\u00fcl\u00fcn canl\u0131 par\u00e7alar\u0131yla yanl\u0131\u015f temas yan\u0131klara, k\u0131v\u0131lc\u0131mlara ve \u00f6l\u00fcmc\u00fcl \u015foka neden olabilir. \u2022 Mod\u00fcl korumas\u0131 i\u00e7in \u00f6n cam kullan\u0131lmaktad\u0131r. K\u0131r\u0131k cam elektrik g\u00fcvenli\u011fi tehlikesine neden olabilir (elektrik \u00e7arpmas\u0131na veya yang\u0131na neden olabilir). Bu mod\u00fcller tamir edilemez ve derhal \u00e7\u0131kar\u0131l\u0131p de\u011fi\u015ftirilmelidir. \u2022 Arka cam\u0131n k\u0131r\u0131lmas\u0131 (iki y\u00fczeyli FV mod\u00fcllerinde) elektrik g\u00fcvenli\u011fi sorununa da yol a\u00e7abilir. Monofacial mod\u00fcllerde oldu\u011fu gibi, bu durum tamir edilemez ve mod\u00fcllerin ba\u011flant\u0131s\u0131 kesilip hemen de\u011fi\u015ftirilmelidir. \u2022 Mod\u00fcller i\u00e7in spesifikasyon tablosu, standart test ko\u015fullar\u0131 alt\u0131nda olu\u015fturulmu\u015ftur (I\u015f\u0131n\u0131m 1000W\/m2, mod\u00fcl h\u00fccre s\u0131cakl\u0131\u011f\u0131 25oC, hava k\u00fctlesi=1,5). Farkl\u0131 ortamlardaki mod\u00fcller taraf\u0131ndan \u00fcretilen ak\u0131m ve gerilim, \u00f6zellik tablosunda listelenenlerden farkl\u0131d\u0131r. Bu nedenle, anma gerilimi, kablo kapasitesi, sigorta kapasitesi, kontrol\u00f6r kapasitesi ve di\u011fer \u00e7\u0131k\u0131\u015f g\u00fcc\u00fc ile ilgili \u00f6zelliklerin \u00f6zelliklerini belirlerken, mod\u00fcl \u00fczerinde i\u015faretlenen k\u0131sa devre ak\u0131m\u0131 ve a\u00e7\u0131k devre geriliminin 1,25 kat\u0131 de\u011ferlerini referans olarak al\u0131n ve sistem konfig\u00fcrasyon tasar\u0131m\u0131 i\u00e7in evirici\/denetleyici tedarik\u00e7inize dan\u0131\u015f\u0131n. \u2022 T\u00fcm teslimatlar s\u0131ras\u0131nda, mod\u00fcllerin nakliye s\u0131ras\u0131nda d\u00fczene\u011fe zarar verebilecek veya mod\u00fcl h\u00fccrelerinde \u00e7atlaklara neden olabilecek b\u00fcy\u00fck darbelere maruz kalmamas\u0131na dikkat edilmelidir. \u2022 Elektrik y\u00fck\u00fc varken, izinsiz bile\u015fenlerin ba\u011flant\u0131s\u0131n\u0131 kesmeyin; Konekt\u00f6r ba\u011flant\u0131s\u0131n\u0131n kesilmesi gerekiyorsa, \u00f6nce DC ve AC eviriciler kapat\u0131lmal\u0131 veya eviricinin ana \u015falteri kesilmelidir. \u2022 Ak\u00fc depolama sistemi FV sistemine ba\u011fland\u0131\u011f\u0131nda, sistemin \u00e7al\u0131\u015fmas\u0131n\u0131 korumak ve kullan\u0131c\u0131 g\u00fcvenli\u011fini sa\u011flamak i\u00e7in ak\u00fc do\u011fru \u015fekilde tak\u0131lmal\u0131d\u0131r; Kurulum, \u00e7al\u0131\u015ft\u0131rma ve bak\u0131m i\u00e7in ak\u00fc \u00fcreticisinin talimatlar\u0131na uyun. \u2022 Mod\u00fcl\u00fcn y\u00fczeyine a\u015f\u0131r\u0131 g\u00fc\u00e7 veya nesne uygulamay\u0131n, darbe uygulamay\u0131n ve mod\u00fcl\u00fcn \u00e7er\u00e7evesini b\u00fckmeyin, aksi takdirde h\u00fccreler zarar g\u00f6rebilir veya h\u00fccrelerin \u00e7atlamas\u0131na neden olabilir. \u2022 Mod\u00fcl\u00fc binalar\u0131n \u00e7at\u0131lar\u0131n\u0131 ve duvarlar\u0131n\u0131 de\u011fi\u015ftirmek veya k\u0131smen de\u011fi\u015ftirmek i\u00e7in kullanmay\u0131n. \u2022 \u00dcretici taraf\u0131ndan imal edilmi\u015f herhangi bir par\u00e7ay\u0131 \u00e7\u0131karmay\u0131n veya mod\u00fcl\u00fc demonte etmeyin. \u2022 Mod\u00fcl kablolar\u0131 veya ba\u011flant\u0131 kutusunu kullanarak mod\u00fclleri kald\u0131rmay\u0131n. \u2022 Mod\u00fcller (cam, ba\u011flant\u0131 kutular\u0131, konekt\u00f6rler vb.), \u00fcr\u00fcn i\u00e7in korozyon riski olu\u015fturabilecek k\u00fck\u00fcrt, asit, alkali vb. i\u00e7eren ortamlara ve mod\u00fcl arka kaplamas\u0131n\u0131 yok edebilecek organik \u00e7\u00f6z\u00fcc\u00fclere uzun s\u00fcre maruz kalmaktan korunacakt\u0131r. \u2022 Ba\u011flant\u0131 kutusu IP68 (IEC60529) gereksinimlerini kar\u015f\u0131lamal\u0131d\u0131r, ancak do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan ve suya dald\u0131rmadan korunmal\u0131d\u0131r. Di\u015fi-erkek konekt\u00f6rlerin ara ba\u011flant\u0131s\u0131, IP68 (IEC60529) gereksinimlerini kar\u015f\u0131lamal\u0131d\u0131r. Ancak konekt\u00f6r\u00fcn su alt\u0131nda uzun s\u00fcre kullan\u0131lmas\u0131 \u00f6nerilmez. \u2022 Ba\u011flant\u0131 kutusu konekt\u00f6r\u00fc, konekt\u00f6re zarar vermemek i\u00e7in ya\u011fl\u0131 maddeler, organik \u00e7\u00f6z\u00fcc\u00fcler ve alkol, benzin, ya\u011flay\u0131c\u0131lar, pas \u00f6nleyiciler, herbisitler gibi di\u011fer a\u015f\u0131nd\u0131r\u0131c\u0131 maddelerle temas halinde olmamal\u0131d\u0131r. Konekt\u00f6r kirlenmi\u015fse, yenisiyle de\u011fi\u015ftirilmesi gerekir. \u2022 \u015eekil 72\u2019de g\u00f6sterildi\u011fi gibi panelin \u00fczerine \u00e7\u0131kmay\u0131n veya basmay\u0131n. Bu yasakt\u0131r ve mod\u00fcle zarar verme ve kullan\u0131c\u0131n\u0131n yaralanma riski vard\u0131r. MOD\u00dcL 4 - 49","\u015eekil 72. Panel montaj\u0131nda yanl\u0131\u015f uygulamalar \u2022 Canl\u0131 terminallere \u00e7\u0131plak elle dokunmay\u0131n. Elektrik ba\u011flant\u0131lar\u0131 i\u00e7in yal\u0131t\u0131ml\u0131 aletler kullan\u0131n (\u015eekil 73). \u015eekil 73. Panel montaj\u0131 \u00f6ncesi i\u015f g\u00fcvenli\u011fi \u2022 Yapay olarak yo\u011funla\u015ft\u0131r\u0131lm\u0131\u015f g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131 mod\u00fcle y\u00f6nlendirilmemelidir. Monofacial mod\u00fcl\u00fcn arkas\u0131n\u0131 do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131na maruz b\u0131rakmay\u0131n. \u2022 FV mod\u00fcller ilgili mekanik y\u00fck ihtiyac\u0131na g\u00f6re uygun \u015fekilde kurulmal\u0131d\u0131r. \u2022 Mod\u00fcl kurulumunun maksimum y\u00fcksekli\u011fi 2000m'dir. \u2022 Deniz k\u0131y\u0131s\u0131na minimum mesafe 50 m'dir. \u2022 Yans\u0131ma \u00f6nleyici (AR) kaplama teknolojisine sahip FV mod\u00fcllerine bak\u0131ld\u0131\u011f\u0131nda, baz\u0131 h\u00fccrelerin farkl\u0131 a\u00e7\u0131larda hafif renk fark\u0131yla g\u00f6r\u00fclmesi normal olacakt\u0131r. \u2022 Mod\u00fcllerin montaj\u0131ndan \u00f6nce, ya\u011fmur ve g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131na do\u011frudan maruz kalmamalar\u0131 i\u00e7in mod\u00fcllerin ya\u011fmur ge\u00e7irmez bir ortamda muhafaza edilmesi tavsiye edilir. 2.2. MONTAJ \u00d6NCES\u0130 \u0130\u015e G\u00dcVENL\u0130\u011e\u0130 \u2022 Kurulum s\u0131ras\u0131nda her zaman baret, yal\u0131t\u0131ml\u0131 eldivenler ve yal\u0131t\u0131ml\u0131 i\u015f ayakkab\u0131lar\u0131 giyin ve di\u011fer koruyucu \u00f6nlemleri al\u0131n. \u2022 FV sistemini kurarken elektrik \u00e7arpmas\u0131 tehlikesine yol a\u00e7mamak ve mod\u00fcllere zarar vermemek i\u00e7in l\u00fctfen metal y\u00fcz\u00fckler, saatler ve di\u011fer metal \u00fcr\u00fcnleri takmay\u0131n. \u2022 Kuruluma kadar mod\u00fcl\u00fc paketinden \u00e7\u0131kar\u0131n. Mod\u00fcller paletten \u00e7\u0131kar\u0131ld\u0131ktan sonra kurulmal\u0131 ve eviriciye ba\u011flanmal\u0131d\u0131r. Derhal monte edilmeyeceklerse ba\u011flant\u0131 noktalar\u0131na koruyucu \u00f6nlemler (kau\u00e7uk derz kapa\u011f\u0131 eklenmesi vb.) al\u0131nmal\u0131d\u0131r. \u2022 Kurulum s\u0131ras\u0131nda gerekli olmad\u0131k\u00e7a FV mod\u00fcl\u00fcne \u00e7\u0131plak elle dokunmay\u0131n. Cam y\u00fczey ve \u00e7er\u00e7eve s\u0131cak olabilir. Yanma ve elektrik \u00e7arpmas\u0131 riski vard\u0131r. Mod\u00fclleri kurarken standart g\u00fcvenlik ara\u00e7lar\u0131n\u0131 ve ekipmanlar\u0131n\u0131 kullan\u0131n. \u2022 Ya\u011fmur, kar veya r\u00fczgarl\u0131 havalarda \u00e7al\u0131\u015fmay\u0131n\u0131z. \u2022 Elektrik \u00e7arpmas\u0131 riski nedeniyle mod\u00fcl\u00fcn kablolar\u0131 \u0131slakken herhangi bir i\u015flem yapmay\u0131n. MOD\u00dcL 4 - 50","\u2022 Yal\u0131t\u0131lm\u0131\u015f aletler kullan\u0131n ve \u0131slak aletler kullanmay\u0131n. \u2022 Erkek ve di\u015fi konekt\u00f6rleri do\u011fru \u015fekilde ba\u011flay\u0131n, kablolama durumunu kontrol edin, t\u00fcm kablolar mod\u00fcllerden ayr\u0131lmamal\u0131d\u0131r ve kablolar\u0131n mod\u00fcllerin arka tabakas\u0131n\u0131 \u00e7izmemesi veya s\u0131k\u0131\u015ft\u0131rmamas\u0131 i\u00e7in kablo ba\u011flar\u0131 ile sabitleyin. \u2022 Mod\u00fcl sisteme ba\u011fl\u0131 veya sistemden ayr\u0131lm\u0131\u015f olsun, kurulum s\u0131ras\u0131nda veya g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131 alt\u0131nda ba\u011flant\u0131 kutusuna veya konekt\u00f6rlere \u00e7\u0131plak elle dokunmay\u0131n. \u2022 \u00c7er\u00e7evede korozyona veya mod\u00fclde di\u011fer olumsuz etkilere neden olabilecek delikler a\u00e7may\u0131n. \u2022 Mod\u00fcllerde termal genle\u015fme ve so\u011fuk b\u00fcz\u00fclme etkisi olu\u015fur. Kurulum s\u0131ras\u0131nda, iki biti\u015fik mod\u00fcl aras\u0131ndaki aral\u0131\u011f\u0131n \u2265 10 mm olmas\u0131 \u00f6nerilir. \u0130ki biti\u015fik \u00e7ift caml\u0131 mod\u00fcl aras\u0131ndaki minimum bo\u015fluk \u2265 20 mm \u00f6nerilir; \u00d6zel gereksinimler varsa, l\u00fctfen kurulumdan \u00f6nce \u00fcretici g\u00f6r\u00fc\u015f\u00fcn\u00fcz. \u2022 \u00c7at\u0131 \u00fcst\u00fc kurulumlar i\u00e7in, mod\u00fcller ve \u00e7at\u0131 aras\u0131nda \u00f6nerilen minimum mesafe 10 cm'dir. \u2022 Kurulum s\u0131ras\u0131nda, mod\u00fcl\u00fcn s\u00f6k\u00fclmesi, bak\u0131m\u0131 ve ilgili di\u011fer i\u015flemlerde oldu\u011fu gibi, kablo ile konekt\u00f6r ve kablo ile ba\u011flant\u0131 kutusu aras\u0131nda uygulanan kuvvetin 60N'den fazla olmamas\u0131 \u00f6nerilir. \u2022 \u00c7at\u0131ya kurulum i\u00e7in, temizlik, onar\u0131m ve bak\u0131m kolayl\u0131\u011f\u0131 i\u00e7in y\u00fcr\u00fcme yollar\u0131n\u0131n ayr\u0131lmas\u0131 \u00f6nerilir. \u2022 Mod\u00fcllerin kurulumu i\u00e7in \u00f6nerilen hava ko\u015fullar\u0131 \u015funlard\u0131r: Nem: <%85 Ba\u011f\u0131l Nem, ortam hava s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131: -40\u00b0C ila + 40\u00b0C, s\u0131n\u0131r \u00e7al\u0131\u015fma ortam s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131: -40\u00b0C ila + 70\u00b0C \u2022 FV mod\u00fcl\u00fcn\u00fc a\u00e7\u0131k alev veya yan\u0131c\u0131 malzemelerin yak\u0131n\u0131na kurmay\u0131n. \u2022 FV mod\u00fcl\u00fcn\u00fc suya dald\u0131r\u0131laca\u011f\u0131 veya s\u00fcrekli olarak f\u0131skiye veya f\u0131skiye vb. sulara maruz kalaca\u011f\u0131 bir yere kurmay\u0131n. \u2022 FV mod\u00fclleri deniz k\u0131y\u0131s\u0131ndan en az 50 m uza\u011fa kurulabilir. Mod\u00fcllerin deniz k\u0131y\u0131s\u0131ndan 50m ila 500m uzakl\u0131\u011fa monte edilmesi durumunda konekt\u00f6rler korunmal\u0131d\u0131r, yani toz tapalar\u0131 eklenmelidir. Toz tapalar\u0131n\u0131 \u00e7\u0131kard\u0131ktan sonra konekt\u00f6rleri hemen ba\u011flay\u0131n ve paslanmay\u0131 \u00f6nlemek i\u00e7in paslanmaya kar\u015f\u0131 di\u011fer \u00f6nlemleri al\u0131n. 2.3. TA\u015eIMA G\u00dcVENL\u0130\u011e\u0130 \u2022 FV mod\u00fcl\u00fc, mod\u00fcl\u00fcn ba\u011flant\u0131 kutusunu veya elektrik u\u00e7lar\u0131n\u0131 kavrayarak kald\u0131r\u0131lmamal\u0131d\u0131r. \u2022 FV mod\u00fcllerin \u00fczerine \u00e7\u0131k\u0131lmamal\u0131 veya \u00fczerine bas\u0131lmamal\u0131 veya \u00fczerine a\u011f\u0131r nesneler konulmamal\u0131d\u0131r. \u2022 FV mod\u00fcl\u00fc d\u00fc\u015f\u00fcr\u00fclmemeli veya nesnelerin FV mod\u00fcl \u00fczerine d\u00fc\u015fmesine izin verilmemelidir. \u2022 FV mod\u00fclleri ta\u015f\u0131rken ve kurarken dikkatli olunmal\u0131d\u0131r. \u2022 FV mod\u00fcl\u00fcn \u00fcst y\u00fczeyine boya veya yap\u0131\u015ft\u0131r\u0131c\u0131 uygulanmamal\u0131d\u0131r. \u2022 \u00c7er\u00e7eveye delik a\u00e7\u0131lmamal\u0131d\u0131r. Delik a\u00e7\u0131lmas\u0131 halinde \u00e7er\u00e7evenin mekanik mukavemeti azalabilir ve titre\u015fim nedeniyle h\u00fccrelerde mikro \u00e7atla\u011fa neden olabilir. \u2022 \u00c7er\u00e7evenin eloksal kaplamas\u0131n\u0131 k\u0131r\u0131lmamal\u0131\/s\u0131y\u0131r\u0131lmamal\u0131 (topraklama ba\u011flant\u0131s\u0131 hari\u00e7), bu durum \u00e7er\u00e7evede korozyon\/paslanmas\u0131na neden olabilir. \u2022 Elektrik \u00e7arpmas\u0131 tehlikesi olan k\u0131r\u0131k caml\u0131 veya arka y\u00fcz\u00fc y\u0131rt\u0131lm\u0131\u015f FV mod\u00fcller kullan\u0131lmamal\u0131d\u0131r. \u2022 Uygun korumaya sahip olmad\u0131\u011f\u0131 s\u00fcrece FV mod\u00fclleri \u0131slak durumda tutulmamal\u0131d\u0131r. \u2022 Gereksiz degredasyonu \u00f6nlemek i\u00e7in kuruluma kadar FV mod\u00fcl\u00fc g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131na maruz b\u0131rak\u0131lmamal\u0131d\u0131r. \u2022 Nakliye s\u00fcreci boyunca FV mod\u00fclde \u015fiddetli titre\u015fim olmad\u0131\u011f\u0131ndan emin olunmal\u0131d\u0131r. Bu titre\u015fimler h\u00fccrede mikro \u00e7atlaklar\u0131na sebep olabilir veya mod\u00fcle zarar verebilir. 2.4. MONTAJIN YAPILMASI Mod\u00fcller genellikle c\u0131vatalar ve klempler kullan\u0131larak monte edilebilir: Kurulumdan \u00f6nce a\u015fa\u011f\u0131daki hususlar ele al\u0131nacakt\u0131r: a) Mod\u00fclde herhangi bir hasar olup olmad\u0131\u011f\u0131n\u0131 g\u00f6rsel olarak kontrol edin. Kir veya kal\u0131nt\u0131 kal\u0131rsa mod\u00fcl\u00fc temizleyin; b) Mod\u00fcl seri numaras\u0131 etiketlerinin e\u015fle\u015fip e\u015fle\u015fmedi\u011fini kontrol edin. MOD\u00dcL 4 - 51","Farkl\u0131 tipteki mod\u00fcllerin \u00f6n tarafta ve arka tarafta dayanabilece\u011fi maksimum y\u00fckler, a\u015fa\u011f\u0131da belirtilen kurulum y\u00f6ntemlerine ba\u011fl\u0131d\u0131r. Mod\u00fcl kurulum sahas\u0131nda yo\u011fun kar ve kuvvetli r\u00fczgar varsa, ger\u00e7ek gereksinimleri kar\u015f\u0131lamak i\u00e7in \u00f6zel koruma al\u0131n. 2.4.1. C\u0131vatalarla Montaj\u0131n Yap\u0131lmas\u0131 Mod\u00fcl\u00fcn uygun \u015fekilde sabitlenmesini sa\u011flamak i\u00e7in paslanmaz c\u0131vatalar, elastik rondelalar ve d\u00fcz rondelalar kullanarak mod\u00fcl\u00fc konstr\u00fcksiyona kurun (\u015eekil 74). S\u0131kma torkunun referans de\u011feri M8 c\u0131vatas\u0131 i\u00e7in 22-30 Nm ve M6 c\u0131vatas\u0131 i\u00e7in 9-12 Nm'dir. \u00d6zel montaj sistemi veya \u00f6zel kurulum y\u00f6ntemi gerekiyorsa, l\u00fctfen konstr\u00fcksiyon sistemi tedarik\u00e7isi ile tork de\u011ferini yeniden teyit edin. \u015eekil 74. C\u0131vatalarla panel montaj\u0131 C\u0131vata montaj\u0131 i\u00e7in kar\u015f\u0131l\u0131k gelen montaj konumlar\u0131na sahip mod\u00fcl modelleri i\u00e7in \u015eekil 75'i inceleyiniz (4 i\u00e7 delik kullan\u0131larak). Tablo 10\u2019da farkl\u0131 montaj delikleri i\u00e7in farkl\u0131 boyutlarda c\u0131vatalar verilmi\u015ftir. Tablo 10. Montaj deliklerine g\u00f6re c\u0131vata boyutlar\u0131 Montaj Deli\u011fi (mm) C\u0131vata Boyutu 14 x 9 M8 10 x 7 M6 \u015eekil 75. C\u0131vata ile montaj\uff08D\u00f6rt farkl\u0131 i\u00e7 C\u0131vata deli\u011finin g\u00f6sterimi\uff09 MOD\u00dcL 4 - 52","2.4.2. Klemplerle Montaj\u0131n Yap\u0131lmas\u0131 Montaj i\u00e7in kullan\u0131lan klempler \u00f6n cama temas etmemeli ve \u00e7er\u00e7eveyi deforme etmemelidir. Klemplerin mod\u00fcller \u00fczerinde g\u00f6lge olu\u015fturmad\u0131\u011f\u0131ndan emin olun. Mod\u00fcl \u00e7er\u00e7evesi hi\u00e7bir ko\u015fulda de\u011fi\u015ftirilmemelidir. Klemp montaj\u0131 i\u00e7in bu kurulum y\u00f6ntemini se\u00e7erken, l\u00fctfen her mod\u00fclde en az d\u00f6rt klemp kulland\u0131\u011f\u0131n\u0131zdan emin olun. Klemplerin farkl\u0131 konumlar\u0131, mod\u00fcllerin ta\u015f\u0131yabilece\u011fi maksimum y\u00fck direncini belirler. \u015eekil 76 klemplerin farkl\u0131 montaj konumlar\u0131na sahip farkl\u0131 montaj y\u00f6ntemlerini g\u00f6stermektedir. \u015eekil 76. Farkl\u0131 montaj yerlerine panel montaj\u0131 Yerel r\u00fczgar ve kar y\u00fcklerine ba\u011fl\u0131 olarak, a\u015f\u0131r\u0131 bas\u0131n\u00e7 y\u00fck\u00fc bekleniyorsa, mod\u00fcl\u00fcn y\u00fck\u00fc ta\u015f\u0131yabilmesi i\u00e7in ek klempler veya destek gerekebilir. Uygulanan tork de\u011feri, mod\u00fclleri g\u00fcvenli bir \u015fekilde sabitlemek i\u00e7in yeterince b\u00fcy\u00fck olmal\u0131d\u0131r. \u015eekil 77\u2019de g\u00f6sterildi\u011fi gibi, mod\u00fcl\u00fcn uzunlu\u011fu ve geni\u015fli\u011fi a ve b ile, uzun kenar\u0131n montaj konumu ile kenar aras\u0131ndaki mesafe c ile temsil edilmektedir. a'n\u0131n minimum uzunlu\u011fu 50 mm ve klemp ile \u00e7er\u00e7eve aras\u0131ndaki temas geni\u015fli\u011fi olan d'nin minimum geni\u015fli\u011fi 8 mm'dir. K\u0131sa kenar klempinin montaj konumu ile kenar aras\u0131ndaki mesafe, \u015eekil 76'da S ile temsil edilir. MOD\u00dcL 4 - 53","\u015eekil 77. Klemp teknik resmi Klemplerle panel montaj\u0131 yap\u0131l\u0131rken \u015eekil 78\u2019deki farkl\u0131 montaj y\u00f6ntemleri kullan\u0131labilir. \u015eekil 78. Kenar klemp ve orta klemp montaj\u0131 MOD\u00dcL 4 - 54","KONU 3 FOTOVOLTA\u0130K PANELLER\u0130N KABLO MONTAJI 3.1. G\u0130R\u0130\u015e G\u00fcne\u015f paneli \u0131\u015f\u0131\u011fa maruz kald\u0131\u011f\u0131nda elektrik \u00fcretir. Ge\u00e7erli t\u00fcm elektriksel g\u00fcvenlik \u00f6nlemlerine uyulmal\u0131d\u0131r. Kablolama bile\u015fenleri, FV mod\u00fclleri ile uyumlu olmal\u0131d\u0131r. Seri ba\u011flanan FV mod\u00fcller benzer ak\u0131ma sahip olacakt\u0131r. Bir FV dizisinin Voc de\u011feri, maksimum sistem voltaj\u0131ndan y\u00fcksek olmamal\u0131d\u0131r (Etikette i\u015faretlenen maksimum sistem voltaj\u0131 de\u011ferini referans al\u0131nmal\u0131d\u0131r.). FV dizinin Voc de\u011feri hesaplan\u0131rken, Voc s\u0131cakl\u0131k katsay\u0131s\u0131 \u00f6zelli\u011fi ve kurulum yerinin a\u015f\u0131r\u0131 d\u00fc\u015f\u00fck s\u0131cakl\u0131\u011f\u0131 dikkate al\u0131nmal\u0131d\u0131r. Paralel ba\u011flanan FV mod\u00fcller benzer Voltaja sahip olacakt\u0131r. FV dizisinin Isc de\u011ferini hesaplarken, Isc s\u0131cakl\u0131k katsay\u0131s\u0131 \u00f6zelli\u011fi ve kurulum yerinin a\u015f\u0131r\u0131 y\u00fcksek s\u0131cakl\u0131\u011f\u0131 dikkate al\u0131nmal\u0131d\u0131r. Kesit alan\u0131 ve kablo konekt\u00f6r kapasitesi, FV sisteminin maksimum k\u0131sa devresini kar\u015f\u0131lamal\u0131d\u0131r. Tek bir bile\u015fen i\u00e7in, kablolar\u0131n kesit alan\u0131n\u0131n 4 mm2 olmas\u0131 ve konekt\u00f6rlerin ak\u0131m\u0131n\u0131n 15A'dan fazla olmas\u0131 \u00f6nerilmektedir, aksi takdirde kablolar ve konekt\u00f6rler y\u00fcksek ak\u0131mdan dolay\u0131 a\u015f\u0131r\u0131 \u0131s\u0131nabilir. Kablolar\u0131n s\u0131cakl\u0131k s\u0131n\u0131r\u0131 genellikle 85 \u00b0C ve konekt\u00f6r\u00fcn s\u0131cakl\u0131k s\u0131n\u0131r\u0131 105 \u00b0C'dir. Bu duruma dikkat edilmelidir. Kurulumdan \u00f6nce, konekt\u00f6r\u00fcn iyi korundu\u011fundan ve konekt\u00f6rde toprak, kum, \u00e7ak\u0131l gibi yabanc\u0131 maddeler bulunmad\u0131\u011f\u0131ndan emin olunmal\u0131d\u0131r. B\u00f6yle bir durum varsa kurulumdan \u00f6nce temizlenmelidir. Konekt\u00f6r zarar g\u00f6rm\u00fc\u015f ve deforme olmu\u015fsa kullanmadan \u00f6nce konekt\u00f6r de\u011fi\u015ftirilmelidir. Arazi sistemlerinde kablolar sark\u0131k halde b\u0131rak\u0131lmamal\u0131 do\u011fru reglaj uygulamas\u0131 yap\u0131lmal\u0131d\u0131r (\u015eekil 79). \u015eekil 79. Do\u011fru ve yanl\u0131\u015f reglaj uygulamas\u0131 3.2. TOPRAKLAMA KABLOSU MONTAJI Listelenen bir topraklama \/ ba\u011flama cihaz\u0131n\u0131 ba\u011flamak i\u00e7in ortak topraklama donan\u0131m\u0131n\u0131n (somunlar, c\u0131vatalar, y\u0131ld\u0131z pullar, d\u00f6k\u00fclm\u00fc\u015f halka kilit pullar\u0131, d\u00fcz pullar ve benzerleri) kullan\u0131ld\u0131\u011f\u0131 yerlerde, ek, topraklama cihaz\u0131 \u00fcreticisinin talimatlar\u0131na uygun olarak yap\u0131lmal\u0131d\u0131r. Topraklama gerekiyorsa, topraklama kablosu i\u00e7in \u00f6nerilen bir konekt\u00f6r tipi veya e\u015fde\u011feri kullan\u0131lmal\u0131d\u0131r. Topraklama gerekliyse, yeterli elektrik ba\u011flant\u0131s\u0131n\u0131 sa\u011flamak i\u00e7in topraklama kablosu mod\u00fcl \u00e7er\u00e7evesine uygun \u015fekilde ba\u011flanmal\u0131d\u0131r. Topraklama deli\u011fi \u015eekil 80\u2019de g\u00f6sterilmi\u015ftir. MOD\u00dcL 4 - 55","Sistem y\u00fcksek nem ve y\u00fcksek s\u0131cakl\u0131k ko\u015fullar\u0131nda \u00e7al\u0131\u015ft\u0131\u011f\u0131nda, daha y\u00fcksek g\u00fc\u00e7 d\u00fc\u015f\u00fc\u015f oran\u0131n\u0131 riskini azaltmak i\u00e7in sistemin negatif topraklamas\u0131na izin veren trafo tabanl\u0131 evirici (inverter) tavsiye edilir. \u015eekil 80. Topraklama kablosu montaj\u0131 MOD\u00dcL 4 - 56","KONU 4 EV\u0130R\u0130C\u0130LER\u0130N MEKAN\u0130K MONTAJI 4.1. MERKEZ\u0130 EV\u0130R\u0130C\u0130LER Merkezi eviriciler (\u015eekil 81) enerji ak\u0131\u015f\u0131n\u0131n tek bir yerden merkezden yap\u0131ld\u0131\u011f\u0131 evirici \u00e7e\u015fididir. \u015eekil 82\u2019 de merkezi eviricili bir sistemin \u00e7al\u0131\u015fma \u015femas\u0131 g\u00f6sterilmektedir. G\u00fcne\u015f panellerinin olu\u015fturdu\u011fu diziler birle\u015ferek bir do\u011fru ak\u0131m toplama panosuna getirilir. DC toplama panolar\u0131nda birle\u015ftirilen DC g\u00fc\u00e7 DC kablolarla merkezi eviricilere ta\u015f\u0131n\u0131r. \u00d6zellikle MW boyutunda b\u00fcy\u00fck g\u00fc\u00e7l\u00fc santrallerde tercih edilir. Tek bir noktadan enerji iletimi sa\u011fland\u0131\u011f\u0131ndan kablo ve i\u015f\u00e7ilik maliyetleri dize eviricilere oranla \u00e7ok daha azd\u0131r. Merkezi eviriciler kendi i\u00e7in birka\u00e7 g\u00fc\u00e7 blo\u011funa ayr\u0131l\u0131r. Bu bloklar bir barada birle\u015ferek enerjiyi trafoya iletir. G\u00fc\u00e7 bloklar\u0131n\u0131n g\u00fc\u00e7 miktarlar\u0131 b\u00fcy\u00fck oldu\u011fundan bir ar\u0131za durumunda dize eviricilere g\u00f6re daha fazla \u00fcretim kayb\u0131 riski ta\u015f\u0131rlar. \u0130\u015fletme ve bak\u0131mda evirici \u00fcreticisinin servis kalitesi b\u00fcy\u00fck \u00f6nem ta\u015f\u0131maktad\u0131r. \u015eekil 81. 5 MW g\u00fcc\u00fcnde bir merkezi evirici \u015eekil 82. Merkezi eviricili sistem \u00e7al\u0131\u015fma \u015femas\u0131 MOD\u00dcL 4 - 57","4.1.1. Merkezi Eviricilerin Montaj\u0131 Merkezi eviricilerin tasar\u0131mlar\u0131 markadan markaya de\u011fi\u015fmekle birlikte hava so\u011futmal\u0131 veya ya\u011f so\u011futmal\u0131 tipleri mevcuttur. Merkezi eviricilerin montaj\u0131 \u00fcreticiye ait uzman teknik personeller taraf\u0131ndan yap\u0131lmaktad\u0131r. Piyasada kullan\u0131lan 5 MW g\u00fcc\u00fcndeki bir merkezi eviriciye ait montaj prosed\u00fcr\u00fc genel kapsamda k\u0131saca bahsedilecektir. Eviricinin \u00e7al\u0131\u015fma \u015femas\u0131 \u015eekil 83\u2019de verilmi\u015ftir. \u015eekil 83. Merkezi evirici \u00e7al\u0131\u015fma \u015femas\u0131 MOD\u00dcL 4 - 58","a) Merkezi Eviricinin Saklanmas\u0131 ve Kald\u0131r\u0131lmas\u0131 \u2022 Eviriciyi daima dik konumda saklay\u0131n. \u2022 Evirici istasyonunun i\u00e7inde yo\u011fu\u015fmay\u0131 \u00f6nlemek i\u00e7in, kuru (\u0131s\u0131t\u0131lm\u0131\u015f) bir depoda i\u00e7 mekanda saklay\u0131n. Bu m\u00fcmk\u00fcn de\u011filse, i\u00e7 s\u0131cakl\u0131\u011f\u0131n d\u0131\u015f s\u0131cakl\u0131ktan daha fazla oldu\u011fundan emin olmak i\u00e7in eviricilerin i\u00e7 \u0131s\u0131t\u0131c\u0131lar\u0131n\u0131 besleyin ve a\u00e7\u0131n. \u2022 Evirici istasyonunun i\u00e7ini (\u015eekil 84) ya\u011fmur suyu ve tozdan koruyun. Hava \u00e7\u0131k\u0131\u015flar\u0131 \u00fczerinde kapaklar kullan\u0131n. Depolama s\u0131ras\u0131nda kap\u0131lar\u0131 gereksiz yere a\u00e7may\u0131n veya nakliye plakalar\u0131n\u0131 \u00e7\u0131karmay\u0131n. \u2022 Evirici istasyonunu koruyucu ambalaj\u0131ndan \u00e7\u0131kar\u0131rsan\u0131z ve depolama alan\u0131nda yo\u011fu\u015fma olabilir: \u2022 \u00dcnitenin i\u00e7 s\u0131cakl\u0131\u011f\u0131n\u0131 d\u0131\u015f s\u0131cakl\u0131\u011f\u0131n \u00fczerinde tutmak i\u00e7in dahili \u0131s\u0131t\u0131c\u0131lara g\u00fc\u00e7 sa\u011flay\u0131n. \u2022 Elektrik yoksa, evirici istasyonunun i\u00e7ine nem kurutucu torbalar ekleyin. \u015eekil 84. Merkezi evirici i\u00e7 g\u00f6r\u00fcn\u00fcm\u00fc \u2022 Evirici istasyonunun alt\u0131ndaki zeminin sa\u011flam, d\u00fcz, kuru ve bitki \u00f6rt\u00fcs\u00fc i\u00e7ermedi\u011finden emin olun. Zeminin evirici istasyonuna a\u015fa\u011f\u0131dan e\u015fit \u015fekilde destek verdi\u011finden emin olun. B\u00fck\u00fclme veya stres olmamal\u0131d\u0131r. Evirici istasyonunu \u00e7\u0131plak zemine koymay\u0131n \u00e7\u00fcnk\u00fc bu, boya hasar\u0131na ve korozyona neden olabilir. \u2022 Evirici istasyonunu ah\u015fap destek kiri\u015fleri \u00fczerinde tutun. Bunlar\u0131 d\u00f6rt d\u0131\u015f k\u00f6\u015fenin alt\u0131na ve evirici istasyonunun ortas\u0131na e\u015fit olarak en az iki nokta koyun. \u2022 Evirici istasyonunun k\u00f6\u015felerini darbeye kar\u015f\u0131 koruyun. \u2022 Megavat istasyonunu, HQ 40 'tip A i\u00e7in ISO 3874'e g\u00f6re \u00fcst k\u00f6\u015felerdeki veya alt k\u00f6\u015felerdeki d\u00f6rt kald\u0131rma g\u00f6z\u00fcnden kald\u0131r\u0131n. \u2022 Kald\u0131rma s\u0131ras\u0131nda evirici istasyonunun e\u011filmemesi i\u00e7in kald\u0131rma sapanlar\u0131n\u0131n uzunluklar\u0131n\u0131 ayarlay\u0131n (\u015eekil 85). \u2022 Kald\u0131rma ask\u0131lar\u0131n\u0131n duvarlar\u0131 veya \u00e7at\u0131y\u0131 \u00e7izmesine izin vermeyin. Hasarl\u0131 boya korozyona neden olabilir. \u2022 D\u00f6nmeyi \u00f6nlemek i\u00e7in megavat istasyonunun alt k\u00f6\u015fesine ba\u011fl\u0131 bir k\u0131lavuz tel kullan\u0131n. \u2022 Yaln\u0131zca yetkili kald\u0131rma ekipman\u0131 ve personeli kullan\u0131n. \u2022 Y\u00fck\u00fcn alt\u0131na kimsenin girmesini \u00f6nleyin. \u2022 Kald\u0131rma sapanlar\u0131n\u0131 ba\u011flarken veya kald\u0131r\u0131rken \u00e7at\u0131da durmay\u0131n. \u2022 \u00c7at\u0131ya ask\u0131 veya kanca atmay\u0131n. MOD\u00dcL 4 - 59","\u015eekil 85. Merkezi eviricinin kald\u0131r\u0131lmas\u0131 b) Mekanik Montaj Evirici istasyonunu hareket ettirmek, temele sabitlemek ve s\u0131kmak i\u00e7in gerekli ara\u00e7lar: \u2022 Vin\u00e7, forklift veya transpalet (yeterli y\u00fck kapasitesine sahip) \u2022 K\u0131sa ve uzun ba\u015fl\u0131 veya u\u00e7lu Pozidriv ve Torx (2,5 ila 6 mm) tornavidalar \u2022 Tork anahtar\u0131 \u2022 Anahtar ve lokma tak\u0131m\u0131 \u2022 Korozyon riskini \u00f6nlemek i\u00e7in, evirici istasyonu \u00e7evresinde y\u00fczey suyunun birikmesini \u00f6nlemek i\u00e7in evirici istasyonunu \u00e7evresinden daha y\u00fckse\u011fe kurun. \u2022 \u00c7evredeki zeminin y\u00fczeyini metre ba\u015f\u0131na en az 50 mm e\u011fin (40 in\u00e7 ba\u015f\u0131na 2 in\u00e7). Bu, y\u00fczey suyunun evirici istasyonundan akmas\u0131n\u0131 sa\u011flar. \u2022 Temeli planlarken, toprak tipi, donmaya kar\u015f\u0131 koruma, ya\u011fmur miktarlar\u0131 vb. gibi yerel ko\u015fullar\u0131 dikkate al\u0131n. Uygun olmayan bir temel, evirici istasyonunun oturmas\u0131na veya kap\u0131n\u0131n a\u00e7\u0131lmas\u0131nda g\u00fc\u00e7l\u00fcklere neden olabilir. \u2022 Gerekli kablo b\u00fck\u00fclme yar\u0131\u00e7ap\u0131n\u0131 ve montaj odas\u0131n\u0131 dikkate al\u0131n. \u2022 Genellikle, evirici istasyonunun etraf\u0131ndaki servis platformunun en az bir metre geni\u015fli\u011finde olmas\u0131 \u00f6nerilir. \u2022 Yerel zemin ko\u015fullar\u0131na, zeminin y\u00fck ta\u015f\u0131ma kapasitesine ve in\u015faat alan\u0131n\u0131n potansiyel yerel \u00f6zel gereksinimlerine (deprem veya tayfun ankraj\u0131 ihtiyac\u0131 gibi) uygun temelleri se\u00e7in. Temel i\u00e7in yeterince derin bir delik a\u00e7arak ba\u015flay\u0131n. Daima donmaya kar\u015f\u0131 dayan\u0131kl\u0131 bir derinli\u011fe kadar kaz\u0131n ve deli\u011fi bo\u015falt\u0131n. Gerekirse, temel deli\u011fini genel drenaj a\u011f\u0131na ba\u011flay\u0131n veya drenaj borular\u0131n\u0131 suyun zarar vermeyece\u011fi iyi drene edilmi\u015f bir araziye y\u00f6nlendirin. \u015eekil 86\u2019da merkezi evirici yerle\u015fim alan\u0131n\u0131n haz\u0131rlanmas\u0131 g\u00f6sterilmektedir. Zeminin\/Temelin haz\u0131rlanmas\u0131ndaki a\u015famalar \u00f6zetle: 1 Temel ve kablolama i\u00e7in bir delik a\u00e7\u0131n. 2 Kurulum \u00e7ak\u0131l\u0131n\u0131n \u00e7evredeki toprakla kar\u0131\u015fmas\u0131n\u0131 \u00f6nlemek i\u00e7in jeotekstil kullan\u0131n. 3 Deli\u011fin dibine iri \u00e7ak\u0131l ve \u00fcst\u00fcne ince \u00e7ak\u0131l koyun. 4 Temelin alt\u0131ndaki \u00e7ak\u0131l ve topra\u011f\u0131 s\u0131k\u0131\u015ft\u0131r\u0131n MOD\u00dcL 4 - 60","\u015eekil 86. Merkezi evirici yerle\u015fim alan\u0131n\u0131n haz\u0131rlanmas\u0131 \u2022 Evirici \u0130stasyonunun temellere yerle\u015ftirilmesi 1. Temelin seviyesini ve \u00e7evredeki zeminin temel etraf\u0131ndaki e\u011fimini \u00f6l\u00e7\u00fcn. 2. Temelin d\u00fcz oldu\u011fundan emin olun. Temelin evirici istasyonunun alt\u0131ndaki izin verilen maksimum e\u011fimi 0,1 derecedir. 3. Evirici istasyonunu temelin \u00fczerine kald\u0131r\u0131n. Evirici istasyonunu kald\u0131rma talimatlar\u0131na uyun. Kald\u0131rma s\u0131ras\u0131nda kolon temellerinin hareket etmedi\u011finden ve dikey kald\u0131klar\u0131ndan emin olun. Evirici istasyonu sabit olmal\u0131 ve t\u00fcm temel kolonlar\u0131yla do\u011frudan temas halinde olmal\u0131d\u0131r. 4. Evirici istasyonu temel \u00fczerindeyken, evirici istasyonunun y\u00fcksekli\u011fini ve e\u011fimini \u00f6l\u00e7\u00fcn ve evirici istasyonunun etraf\u0131ndaki \u00e7evreleyen zeminin y\u00fczeyinin e\u011fimini inceleyin. \u2022 \u00c7ukurun doldurulmas\u0131 ve \u00e7evrenin sonland\u0131r\u0131lmas\u0131 1. Yerel don ko\u015fullar\u0131 i\u00e7in gerekirse kolon temellerinin etraf\u0131na yal\u0131t\u0131m ekleyin. 2. Deli\u011fi 5 cm\/m e\u011fim a\u00e7\u0131s\u0131yla ince \u00e7ak\u0131lla doldurun. Evirici istasyonunun alt\u0131nda 15 cm hava bo\u015flu\u011fu b\u0131rak\u0131n (\u015eekil 87). 3. \u00c7im b\u00fcy\u00fcmesini en aza indirmek i\u00e7in istasyonun \u00e7evresinde jeotekstil kullan\u0131n. Jeotekstil istasyonun 20 cm alt\u0131na ve evirici istasyonunun \u00e7evresine yakla\u015f\u0131k 80 cm yerle\u015ftirin. 4. Temel, evirici istasyonundan daha b\u00fcy\u00fck de\u011filse ve bir servis platformu olarak kullan\u0131lam\u0131yorsa, evirici istasyonunun d\u00f6rt taraf\u0131n\u0131n etraf\u0131na iki s\u0131ra 500 x 500 mm beton karo d\u00f6\u015feyin. Fayanslar servis personeli i\u00e7in kuru bir yer sa\u011flar ve \u00e7ak\u0131l\u0131n \u00e7\u0131kar\u0131lmas\u0131n\u0131 engeller. MOD\u00dcL 4 - 61","\u015eekil 87. Merkezi eviricinin yere montaj\u0131 \u2022 Hava ko\u015fullar\u0131na kar\u015f\u0131 koruma ba\u015fl\u0131klar\u0131 ekleme 1. Ge\u00e7ici koruyucular\u0131 (1) \u00e7\u0131kar\u0131n (\u015eekil 88). 2. Hava ko\u015fullar\u0131na kar\u015f\u0131 koruma ba\u015fl\u0131klar\u0131n\u0131 (2) ekleyin. \u015eekil 88. Merkezi eviricinin koruma kapaklar\u0131n\u0131n \u00e7\u0131kar\u0131lmas\u0131 c) Son Montaj Kontrollerinin Yap\u0131lmas\u0131 \u2022 Montaj tamamland\u0131ktan sonra a\u015fa\u011f\u0131daki ad\u0131mlar\u0131 takip ederek son kontrolleri tamamlay\u0131n\u0131z. \u2022 \u00c7al\u0131\u015ft\u0131\u011f\u0131ndan emin olmak i\u00e7in t\u00fcm mekanik \u00e7al\u0131\u015ft\u0131rma i\u015flevlerini iki kez \u00e7al\u0131\u015ft\u0131r\u0131n. \u2022 Boya y\u00fczeyini hasar a\u00e7\u0131s\u0131ndan inceleyin. Talimatlara g\u00f6re hasarl\u0131 alanlar\u0131 onar\u0131n. \u2022 Kablo giri\u015flerinin g\u00fcvenli bir \u015fekilde tak\u0131ld\u0131\u011f\u0131ndan emin olun. Kullan\u0131lmayan kablo a\u00e7\u0131kl\u0131klar\u0131n\u0131n koruyucu kapaklar\u0131 oldu\u011fundan emin olun. \u2022 Hava ko\u015fullar\u0131na kar\u015f\u0131 koruma davlumbazlar\u0131n\u0131n tak\u0131l\u0131 oldu\u011fundan ve hava giri\u015f ve \u00e7\u0131k\u0131\u015flar\u0131ndan hava ak\u0131\u015f\u0131n\u0131 hi\u00e7bir \u015feyin s\u0131n\u0131rlamad\u0131\u011f\u0131ndan emin olun. MOD\u00dcL 4 - 62","\u2022 Gev\u015fek ba\u011flant\u0131lar ve aletler gibi t\u00fcm yabanc\u0131 nesneleri Eviriciden \u00e7\u0131kar\u0131n. K\u0131sa devre ar\u0131zalar\u0131na veya ba\u015fka hasarlara neden olabilirler. \u2022 Evirici istasyonunun temiz oldu\u011fundan emin olun. Kirlenmi\u015f y\u00fczeyler korozyon riskini art\u0131racakt\u0131r. \u2022 Evirici istasyonuna gerekli uyar\u0131 etiketlerinin yap\u0131\u015ft\u0131r\u0131ld\u0131\u011f\u0131ndan emin olun. \u2022 Cihaza \u00f6zel k\u0131lavuzlarda ayr\u0131nt\u0131l\u0131 olarak a\u00e7\u0131klanan kurulum kontrollerini yap\u0131n. \u0130\u00e7 \u00f6n kapa\u011fa bak\u0131n. 4.2. D\u0130ZE (STR\u0130NG) EV\u0130R\u0130C\u0130LER G\u00fcne\u015f panellerinin olu\u015fturdu\u011fu diziler birle\u015ferek direkt olarak dize eviriciye ba\u011flan\u0131r. Dize eviricilerde \u00fcretilen enerji bir AC toplama panosunda birle\u015ftirilerek trafoya iletilir. Dize eviricilerde \u00e7ok say\u0131da Maksimum G\u00fc\u00e7 Takip noktas\u0131 (MPPT) bulunur. Bu sayede dize eviriciler farkl\u0131 y\u00f6nde yerle\u015fim gerektiren uygulamalarda (\u00d6rn. \u00e7at\u0131, cephe, e\u011fimli arazi) y\u00fcksek verim sa\u011flad\u0131\u011f\u0131ndan tercih edilmektedir. \u00c7ok say\u0131da noktadan enerji iletimi sa\u011fland\u0131\u011f\u0131ndan kablo ve i\u015f\u00e7ilik maliyetleri merkezi eviricilere oranla biraz daha fazlad\u0131r. Ancak bak\u0131m kolayl\u0131\u011f\u0131 ve ba\u011f\u0131ms\u0131z yap\u0131lar\u0131 nedeniyle merkezi eviriciye g\u00f6re daha g\u00fcvenli bir i\u015fletme sa\u011flar. Evirici de\u011fi\u015fiminde evirici servisi gerektirmez. \u015eekil 89\u2019da Dize eviricili bir sistemin \u00e7al\u0131\u015fma \u015femas\u0131 g\u00f6sterilmektedir. Dize evirici belli say\u0131da FV dizisinden girdi al\u0131r. Bu girdiler evirici i\u00e7indeki MPPT devresine gruplanarak FV dizilerin maksimum g\u00fc\u00e7 noktas\u0131 izlenir. Sonra DC g\u00fc\u00e7 bir evirici devresi yoluyla \u00fc\u00e7 fazl\u0131 AC g\u00fcce d\u00f6n\u00fc\u015ft\u00fcr\u00fcl\u00fcr. A\u015f\u0131r\u0131 gerilim korumas\u0131 hem DC hem de AC tarafta desteklenir. \u015eekil 89. Dize eviricili sistem \u00e7al\u0131\u015fma \u015femas\u0131 Evirici Bekleme (standby), \u00e7al\u0131\u015ft\u0131rma veya kapatma modunda \u00e7al\u0131\u015fabilir (\u015eekil 90). Dize evirici \u00e7al\u0131\u015fma modlar\u0131n\u0131n tan\u0131mlar\u0131 Tablo 11\u2019de a\u00e7\u0131klanmaktad\u0131r. MOD\u00dcL 4 - 63","\u015eekil 90. Dize evirici \u00e7al\u0131\u015fma modlar\u0131 Tablo 11. Dize evirici \u00e7al\u0131\u015fma modlar\u0131n\u0131n tan\u0131mlar\u0131 MOD\u00dcL 4 - 64","4.2.1. Dize Eviricinin Montaj\u0131 a) Dize Eviricinin Saklanmas\u0131 Evirici do\u011frudan kullan\u0131ma al\u0131nmayacaksa a\u015fa\u011f\u0131daki gereklilikler yerine getirilmelidir: \u2022 Ambalaj malzemelerini \u00e7\u0131karmay\u0131n ve ambalaj malzemelerini d\u00fczenli olarak kontrol edin (her \u00fc\u00e7 ayda bir kontrol \u00f6nerilir). Kemirgen izleri bulunursa ambalaj malzemelerini derhal de\u011fi\u015ftirin. Evirici ambalaj\u0131ndan \u00e7\u0131kar\u0131lm\u0131\u015f, ancak hemen kullan\u0131ma al\u0131nmam\u0131\u015fsa, cihaz\u0131 nem giderici paketi ile birlikte tekrar orijinal ambalaj\u0131n\u0131n i\u00e7ine koyun ve ambalaj\u0131 bantlayarak kapat\u0131n. \u2022 Ortam s\u0131cakl\u0131\u011f\u0131 ve ortamdaki nem, depolama i\u00e7in uygun olmal\u0131d\u0131r (\u015eekil 91). Havada a\u015f\u0131nd\u0131r\u0131c\u0131 veya yan\u0131c\u0131 gazlar bulunmamal\u0131d\u0131r. \u015eekil 91. Dize evirici \u00e7al\u0131\u015fma \u015fartlar\u0131 \u2022 Evirici temiz ve kuru bir yerde depolanmal\u0131 ve toz, su, buhar ve korozyondan korunmal\u0131d\u0131r. Evirici ya\u011fmurdan ve sudan korunmal\u0131d\u0131r. \u2022 Ambalaj\u0131 e\u011fmeyin veya ba\u015f a\u015fa\u011f\u0131 yerle\u015ftirmeyin. \u2022 Ki\u015fisel yaralanmalar\u0131 veya cihaz hasarlar\u0131n\u0131 \u00f6nlemek ad\u0131na, eviricilerin devrilmelerini \u00f6nlemek i\u00e7in eviricileri dikkatlice istifleyin. \u2022 \u0130zin verilen maksimum istifleme katman\u0131 say\u0131s\u0131 i\u00e7in evirici k\u0131lavuzunu kontrol ediniz. \u00d6rnek \u015eekil 92\u2019de verilmi\u015ftir. \u015eekil 92. Dize eviricinin istiflenme \u015fartlar\u0131 \u2022 Evirici iki y\u0131ldan uzun bir s\u00fcre depolanm\u0131\u015fsa, kullan\u0131ma al\u0131nmadan \u00f6nce uzmanlar taraf\u0131ndan kontrol ve test edilmelidir. b) Mekanik Kurulum \u2022 Eviriciyi ambalaj\u0131ndan \u00e7\u0131karmadan \u00f6nce, d\u0131\u015f ambalaj materyallerini delikler ve \u00e7atlaklar gibi hasarlara kar\u015f\u0131 kontrol edin ve evirici modelini inceleyin. Herhangi bir hasar bulunursa veya evirici modeli sizin talep etti\u011finiz model de\u011filse, cihaz\u0131 ambalaj\u0131ndan \u00e7\u0131karmay\u0131n ve en k\u0131sa s\u00fcrede tedarik\u00e7iniz ile ileti\u015fim kurun. \u2022 Eviriciyi ambalaj\u0131ndan \u00e7\u0131kard\u0131ktan sonra, i\u00e7eriklerin el de\u011fmemi\u015f ve eksiksiz oldu\u011funu kontrol edin. Herhangi bir hasar veya eksik bile\u015fen bulundu\u011fu takdirde, tedarik\u00e7iniz ile ileti\u015fime ge\u00e7in. MOD\u00dcL 4 - 65","Kurulum \u00f6ncesi Tablo 12\u2019de belirtilen alet setlerinin bulunmas\u0131 gerekmektedir. Tablo 12. Dize evirici kurulumu i\u00e7in gerekli alet setleri. MOD\u00dcL 4 - 66","Kurulum Ortam\u0131 Gereklilikleri \u2022 Eviriciyi \u00e7al\u0131\u015fma ya da ya\u015fam alanlar\u0131na kurmay\u0131n. \u2022 Cihaz \u00e7al\u0131\u015fma ya da ya\u015fam alanlar\u0131 d\u0131\u015f\u0131ndaki kamuya a\u00e7\u0131k alanlarda (park alanlar\u0131, istasyonlar ve fabrikalar gibi) kurulduysa cihaz\u0131 izole etmek ve yetkisiz personelin eviriciye yakla\u015fmas\u0131n\u0131 \u00f6nlemek i\u00e7in cihaz\u0131n etraf\u0131na koruyucu bir a\u011f yerle\u015ftirin ve g\u00fcvenlik uyar\u0131 i\u015fareti koyun. Bu, cihaz\u0131n \u00e7al\u0131\u015fmas\u0131 s\u0131ras\u0131nda yanl\u0131\u015fl\u0131kla dokunma ya da di\u011fer sebeplerden kaynakl\u0131 ki\u015fisel yaralanma ya da mal kay\u0131plar\u0131ndan ka\u00e7\u0131nmak i\u00e7indir. \u2022 Eviriciyi yan\u0131c\u0131 maddelerin bulundu\u011fu alanlara kurmay\u0131n. \u2022 Eviriciyi patlay\u0131c\u0131 maddelerin bulundu\u011fu alanlara kurmay\u0131n. \u2022 Eviriciyi a\u015f\u0131nd\u0131r\u0131c\u0131 maddelerin bulundu\u011fu alanlara kurmay\u0131n. \u2022 Eviriciyi, kasas\u0131n\u0131n ve \u0131s\u0131 havuzlar\u0131n\u0131n kolayca eri\u015filebildi\u011fi yerlere monte etmeyin, \u00e7\u00fcnk\u00fc gerilim y\u00fcksektir ve bu k\u0131s\u0131mlar \u00e7al\u0131\u015fma s\u0131ras\u0131nda \u0131s\u0131n\u0131r. \u2022 Evirici \u0131s\u0131 yayaca\u011f\u0131ndan iyi havaland\u0131r\u0131lan bir ortama kurun \u2022 Evirici hava ge\u00e7irmez bir ortama kurulmu\u015fsa, i\u00e7 ortam s\u0131cakl\u0131\u011f\u0131n\u0131n \u00e7al\u0131\u015fma s\u0131ras\u0131nda d\u0131\u015f ortam s\u0131cakl\u0131\u011f\u0131ndan y\u00fcksek olmamas\u0131n\u0131 sa\u011flamak i\u00e7in bir \u0131s\u0131 da\u011f\u0131t\u0131m cihaz\u0131 veya havaland\u0131rma cihaz\u0131 kurulmal\u0131d\u0131r. \u2022 Eviriciyi korunakl\u0131 veya \u00fczerinde tente bulunan bir yere kurman\u0131z \u00f6nerilir. \u2022 Evirici tuzlu alanlarda korozyona u\u011frayacakt\u0131r. Eviriciyi tuzlu alanlara kurmadan \u00f6nce evirici \u00fcreticisine dan\u0131\u015f\u0131n. Tuzlu alan, sahilden 500 metre mesafedeki bir b\u00f6lgeyi veya deniz esintisine e\u011filimli olan b\u00f6lgeyi ifade eder. Deniz esintisine e\u011filimli olan b\u00f6lgeler, hava ko\u015fullar\u0131na (tayfun ve muson gibi) veya araziye (baraj ve tepe gibi) ba\u011fl\u0131 olarak de\u011fi\u015fir. Montaj Yap\u0131s\u0131 Gereklilikleri \u2022 Eviricinin kuruldu\u011fu montaj yap\u0131s\u0131 yang\u0131na dayan\u0131kl\u0131 olmal\u0131d\u0131r (\u015eekil 93). Eviriciyi yan\u0131c\u0131 yap\u0131 malzemelerinin \u00fczerine monte etmeyin. \u2022 Kurulum y\u00fczeyinin a\u011f\u0131r y\u00fck ta\u015f\u0131yacak kadar sa\u011flam olmas\u0131na dikkat edin. \u2022 Yerle\u015fim b\u00f6lgelerinde evirici, yetersiz ses yal\u0131t\u0131m performans\u0131na sahip al\u00e7\u0131 panel veya benzer materyallerden yap\u0131lm\u0131\u015f duvarlara, eviricinin \u00fcretti\u011fi g\u00fcr\u00fclt\u00fc fark edilebilece\u011finden monte edilmemelidir. \u015eekil 93. Dize eviricinin monte edilece\u011fi yerin \u015fartlar\u0131 Kurulum A\u00e7\u0131s\u0131 Gereklilikleri Evirici, destek monteli veya duvara monteli olabilir. Kurulum a\u00e7\u0131s\u0131 gereksinimleri a\u015fa\u011f\u0131daki gibidir: \u2022 Is\u0131 yay\u0131l\u0131m\u0131n\u0131 kolayla\u015ft\u0131rmak i\u00e7in, eviriciyi dikey olarak veya kullan\u0131m k\u0131lavuzunda belirtilen maksimum arkaya e\u011fim a\u00e7\u0131s\u0131 ile monte edin (\u015eekil 94). \u2022 Eviriciyi \u00f6ne e\u011fimle, a\u015f\u0131r\u0131 arkaya e\u011fimle, yan e\u011fimle, yatay \u015fekilde veya ba\u015f a\u015fa\u011f\u0131 \u015fekillerde kurmay\u0131n. MOD\u00dcL 4 - 67","\u015eekil 94. Dize eviricinin montaj \u015fekli \u2022 Kurulum ve \u0131s\u0131 da\u011f\u0131t\u0131m\u0131 i\u00e7in eviricinin \u00e7evresinde yeterli alan b\u0131rak\u0131n. \u00dcr\u00fcn \u00e7e\u015fidine g\u00f6re de\u011fi\u015fkenlik g\u00f6sterebilmekte olup \u00f6rnek minimum bo\u015fluk \u00f6l\u00e7\u00fcleri \u015eekil 95\u2019de verilmi\u015ftir. \u015eekil 95. Dize eviricinin montaj alan\u0131 i\u00e7in minimum bo\u015fluk \u00f6l\u00e7\u00fcleri Birden \u00e7ok say\u0131da eviricinin kurulumunu ger\u00e7ekle\u015ftirirken, yeterli alan varsa yatay modda (\u015eekil 96) ve yeterli alan bulunmuyorsa kademeli modda (\u015eekil 97) monte edin. Y\u0131\u011f\u0131lm\u0131\u015f kurulum (\u015eekil 98) tavsiye edilmez. MOD\u00dcL 4 - 68","\u015eekil 96. Yatay kurulum \u015fartlar\u0131 \u015eekil 97. Kademeli kurulum \u015fartlar\u0131 \u015eekil 98. Y\u0131\u011f\u0131lm\u0131\u015f kurulum \u015fartlar\u0131 MOD\u00dcL 4 - 69","c) Montaj Braketinin Kurulumu Montaj braketini monte etmeden \u00f6nce, g\u00fcvenlik torku anahtar\u0131n\u0131 \u00e7\u0131kar\u0131n ve daha sonra kullanmak \u00fczere saklay\u0131n. Bir tork anahtar\u0131n\u0131n ba\u011flanmas\u0131 i\u00e7in pozisyon \u015eekil 99\u2019daki gibidir. \u015eekil 99. Tork anahtar\u0131n\u0131n ba\u011flanmas\u0131 i\u00e7in uygun pozisyon Dize evirici montaj braketi evirici markas\u0131na g\u00f6re de\u011fi\u015fmekle birlikte genellikle her bir grupta d\u00f6rt deli\u011fin bulundu\u011fu d\u00f6rt vida deli\u011fi grubuna sahiptir. Saha gerekliliklerine g\u00f6re her grupta herhangi say\u0131da bir deli\u011fi ve toplamda d\u00f6rt deli\u011fi i\u015faretleyin. \u0130ki yuvarlak delik tavsiye edilir. Delik boyutlar\u0131 evirici g\u00fcc\u00fc ve markadan markaya de\u011fi\u015fkenlik g\u00f6sterebilir. \u015eekil 100. Montaj braketi boyutlar\u0131 ve delik \u00e7aplar\u0131 Destek Monteli Kurulum \u2022 Matkap deliklerinin pozisyonlar\u0131n\u0131 montaj braketini kullanarak belirleyin. Bir kabarc\u0131k veya dijital seviye kullanarak montaj deliklerinin konumlar\u0131n\u0131 d\u00fczle\u015ftirin ve konumlar\u0131 bir i\u015faretleyici ile i\u015faretleyin (\u015eekil 101). \u2022 Darbeli matkapla delikleri delin. Delik pozisyonlar\u0131nda koruma i\u00e7in paslanmay\u0131 \u00f6nleyici bir boya kullanman\u0131z \u00f6nerilir. \u2022 Montaj braketini sabitleyin. MOD\u00dcL 4 - 70"]


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook