Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore r_00001_ElKitap_TRready

r_00001_ElKitap_TRready

Published by Perihan Tekeli, 2023-07-10 12:21:21

Description: r_00001_ElKitap_TRready

Search

Read the Text Version

["Uygulama 3: KABLO SAB\u0130TLEME A\u015fa\u011f\u0131daki \u015eekilde g\u00f6r\u00fcld\u00fc\u011f\u00fc gibi 1 metre uzunlu\u011funda ve 15 cm geni\u015fli\u011findeki kablo kanal\u0131na (tavas\u0131na) en az 3 adet solar kabloyu d\u00f6\u015feyerek sabitleyiniz. MOD\u00dcL 5 - 121","Uygulama 4: EV\u0130R\u0130C\u0130 MONTAJI G\u00fcne\u015f paneli sistemi g\u00fc\u00e7 panosu i\u00e7erisine evirici montaj\u0131 yap\u0131p kablo ba\u011flant\u0131lar\u0131n\u0131 yap\u0131n\u0131z. \u0130\u015flem Basamaklar\u0131 \u00d6neriler \u00d8 Panoya monte edilecek uygun \u00d8 \u0130\u015f ile ilgili g\u00fcvenlik tedbirlerini al\u0131p i\u015fe Eviriciyi se\u00e7iniz. ba\u015flamadan \u00f6nce i\u015f elbisesi, i\u015f eldiveni ve i\u015f ayakkab\u0131s\u0131 giyiniz. \u00d8 \u00c7al\u0131\u015fma ortam\u0131n\u0131 haz\u0131rlay\u0131p \u00e7al\u0131\u015fma ortam\u0131 i\u00e7in gerekli olan ara\u00e7 ve gere\u00e7leri temin ediniz. \u00d8 Yap\u0131lacak uygulama i\u00e7in gerekli i\u015f g\u00fcvenli\u011fine dikkat ediniz. \u00d8 Eviriciler hakk\u0131nda katalog ve CD\u2019lerden bilgi edininiz. MOD\u00dcL 5 - 122","\u00d8 Eviriciyi monte etmek i\u00e7in \u00d8 Eviriciyi sadece metal ya da beton gibi panoyu markalay\u0131p uygun yang\u0131na dayan\u0131kl\u0131 malzemelere monte delikleri a\u00e7\u0131n\u0131z. ediniz. Yanabilir malzemeye monte edilmesi yang\u0131na neden olabilir. \u00d8 Montaj i\u00e7in kullan\u0131lacak vida, c\u0131vata ve somunlar\u0131 temin ediniz. \u00d8 Montaj yerinin eviricinin a\u011f\u0131rl\u0131\u011f\u0131na dayanaca\u011f\u0131ndan emin olunuz. \u00d8 Eviriciyi sadece izin verilen montaj pozisyonunda \u00d8 Montaj deliklerini delerken tala\u015f ya da tak\u0131n\u0131z. yabanc\u0131 maddelerin eviricinin i\u00e7ine girmesine izin vermeyiniz. \u00d8 Eviriciyi panoya monte ediniz. \u00d8 \u00c7al\u0131\u015ft\u0131\u011f\u0131n\u0131z yeri her zaman temiz ve d\u00fczenli tutunuz. Statik elektrikten kaynaklanabilecek hasarlar\u0131 \u00f6nlemek i\u00e7in eviriciye dokunmadan \u00f6nce yak\u0131nlardaki bir metal cisme dokunarak v\u00fccudunuzdaki statik elektri\u011fi bo\u015falt\u0131n\u0131z. \u00d8 Montaj esnas\u0131nda sab\u0131rl\u0131 ve dikkatli olunuz. \u00d8 Vidalama esnas\u0131nda viday\u0131 elimizle s\u0131k\u0131 tutmal\u0131 ve tornaviday\u0131 dikkatli kullanmal\u0131s\u0131n\u0131z yoksa elinize zarar verebilirsiniz. \u00d8 Vida ba\u015flar\u0131n\u0131 k\u0131sa devrelere kar\u015f\u0131 yal\u0131t\u0131n\u0131z. \u00d8 Panoya monte edilmi\u015f \u00d8 T\u00fcm kablolar\u0131n do\u011fru konekt\u00f6rlere Eviricinin kablo ba\u011flant\u0131lar\u0131n\u0131 yap\u0131n\u0131z. ba\u011flanm\u0131\u015f oldu\u011fundan emin olunuz. Aksi \u00d8 \u00c7al\u0131\u015fma sonlar\u0131nda \u00e7al\u0131\u015fma takdirde hasarlar ortaya \u00e7\u0131kabilir. ortam\u0131n\u0131z\u0131n tertip d\u00fczen ve \u00d8 T\u00fcm ba\u011flant\u0131larda polaritenin do\u011fru temizli\u011fini sa\u011flay\u0131n\u0131z. olmas\u0131n\u0131 sa\u011flay\u0131n\u0131z. Aksi takdirde hasarlar ortaya \u00e7\u0131kabilir. \u00d8 Kulland\u0131\u011f\u0131n\u0131z gere\u00e7lerin gerekli bak\u0131mlar\u0131n\u0131 yap\u0131p yerlerine koyunuz. Uygulama 5: TOPRAKLAMA (\u00c7ATI) Bir evin \u00e7at\u0131s\u0131 \u00fczerinde bulunan g\u00fcne\u015f paneli sistemine topraklama iletkeni ba\u011flant\u0131s\u0131 yap\u0131n\u0131z. \u0130\u015flem s\u0131ras\u0131nda i\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi tedbirlerini al\u0131n\u0131z. MOD\u00dcL 5 - 123","\u0130\u015flem Basamaklar\u0131 \u00d6neriler \u00d8 G\u00fcne\u015f panel sisteminin topraklamas\u0131 \u00d8 \u0130\u015f ile ilgili g\u00fcvenlik tedbirlerini al\u0131p i\u00e7in kullan\u0131lacak topraklama i\u015fe ba\u015flamadan \u00f6nce i\u015f elbisesi, i\u015f iletkenini temin ediniz. eldiveni ve i\u015f ayakkab\u0131s\u0131 giymelisiniz. \u00d8 Montaj i\u00e7in kullan\u0131lacak vida, c\u0131vata ve somunlar\u0131 temin ediniz. \u00d8 \u00c7al\u0131\u015fma ortam\u0131n\u0131 haz\u0131rlay\u0131p \u00e7al\u0131\u015fma ortam\u0131 i\u00e7in gerekli olan \u00d8 Topraklama kablosunun iyi bir ara\u00e7 ve gere\u00e7leri temin elektriksel temas sa\u011flayabilmesi i\u00e7in etmelisiniz. g\u00fcne\u015f panel sistemi montaj raylar\u0131na uygun aparatlarla kusursuz olarak \u00d8 Yap\u0131lacak uygulama i\u00e7in sabitleyiniz. gerekli i\u015f g\u00fcvenli\u011fine dikkat etmelisiniz. \u00d8 \u00c7al\u0131\u015ft\u0131\u011f\u0131n\u0131z yeri her zaman temiz ve d\u00fczenli tutmal\u0131s\u0131n\u0131z. \u00d8 Topraklama iletkenini g\u00fcne\u015f paneli ray\u0131na monte ediniz. \u00d8 Montaj esnas\u0131nda sab\u0131rl\u0131 ve dikkatli olmal\u0131s\u0131n\u0131z. \u00d8 Vidalama esnas\u0131nda viday\u0131 elinizle s\u0131k\u0131 tutmal\u0131 ve tornaviday\u0131 dikkatli kullanmal\u0131s\u0131n\u0131z yoksa elinize zarar verebilirsiniz. \u00d8 \u00c7al\u0131\u015fma sonlar\u0131nda \u00e7al\u0131\u015fma \u00d8 Kulland\u0131\u011f\u0131n\u0131z gere\u00e7lerin ortam\u0131n\u0131z\u0131n tertip d\u00fczen ve gerekli bak\u0131mlar\u0131n\u0131 yap\u0131p temizli\u011fini sa\u011flay\u0131n\u0131z. yerlerine koymal\u0131s\u0131n\u0131z. MOD\u00dcL 5 - 124","Uygulama 6: TOPRAKLAMA (ARAZ\u0130) A\u00e7\u0131k alanda bulunan g\u00fcne\u015f paneli sehpasna topraklama \u00e7ubu\u011fu ve ba\u011flant\u0131 elemanlar\u0131n\u0131 kullanarak topraklama iletkenini \u00e7ekiniz. \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi a\u00e7\u0131s\u0131ndan gerekli tedbirleri al\u0131n\u0131z. \u0130\u015flem Basamaklar\u0131 \u00d6neriler \u00d8 Projeyi okuyunuz. \u00d8 \u00c7al\u0131\u015fma ortam\u0131n\u0131 haz\u0131rlamal\u0131s\u0131n\u0131z. \u00d8 Uygun topraklama \u00d8 \u0130\u015f g\u00fcvenli\u011fi tedbirlerini almal\u0131s\u0131n\u0131z. \u00d8 Ba\u015flamadan \u00f6nce i\u015f elbisesi, i\u015f eldiveni iletkenini se\u00e7iniz. \u00d8 Montaj i\u00e7in kullan\u0131lacak ve i\u015f ayakkab\u0131s\u0131 giymelisiniz. \u00d8 Temiz ve d\u00fczenli olmal\u0131s\u0131n\u0131z. ba\u011flant\u0131 elemanlar\u0131n\u0131 temin \u00d8 Teodpirnaikzl.ama iletkeninin iyi bir \u00d8 El ve g\u00fc\u00e7 aletlerini (pense, tornavida, yan keski, \u00e7ak\u0131 veya k\u00fc\u00e7\u00fck boy elektriksel temas sa\u011flayabilmesi fal\u00e7ata, kontrol kalemi) kendi ama\u00e7lar\u0131 i\u00e7in g\u00fcne\u015f panel sistemi montaj do\u011frultusunda kullanmal\u0131s\u0131n\u0131z. raylar\u0131na ve panel \u00e7er\u00e7evesine uygun aparatlarla kusursuz \u00d8 Titiz olunuz ve yapt\u0131\u011f\u0131n\u0131z her i\u015flemi olarak sabitleyiniz. kontrol etmelisiniz. \u00d8 Toprak iletkenini topra\u011fa do\u011fru \u00e7ekiniz. \u00d8 Yapt\u0131\u011f\u0131n\u0131z her montaj i\u015flemini g\u00f6zden ge\u00e7irerek standartlara uygun olup \u00d8 Toprak elektroduna olmad\u0131\u011f\u0131n\u0131 kontrol etmelisiniz. iletkeni ba\u011flay\u0131n\u0131z. \u00d8 Dikkatli olmal\u0131s\u0131n\u0131z. \u00d8 Toprak elektrodunu g\u00f6m\u00fcn\u00fcz. \u00d8 \u0130\u015f bitince \u00f6\u011fretmenizi \u00d8 \u00c7al\u0131\u015fma sonunda \u00e7al\u0131\u015fma ortam\u0131n\u0131z\u0131n \u00e7a\u011f\u0131r\u0131p beraberce kontrol ediniz. tertip d\u00fczen ve temizli\u011fini sa\u011flamal\u0131s\u0131n\u0131z. \u00d8 Kulland\u0131\u011f\u0131n\u0131z gere\u00e7lerin gerekli bak\u0131mlar\u0131n\u0131 yapmay\u0131 unutmamal\u0131s\u0131n\u0131z. UUygulama 7: TOPRAKLAMA GE\u00c7\u0130\u015e D\u0130RENC\u0130 \u00d6L\u00c7\u00dcM\u00dc A\u015fa\u011f\u0131daki \u015fekilde \u00f6l\u00e7me sistemini kurarak topraklama direncini \u00f6l\u00e7\u00fcn\u00fcz. MOD\u00dcL 5 - 125","MOD\u00dcL 5 - 126","KONU 4 \u00d6L\u00c7ME VE DE\u011eERLEND\u0130RME Her bir mod\u00fcldeki \u00f6l\u00e7me-de\u011ferlendirme k\u0131sm\u0131nda; \u00f6ncelikle Fotovoltaik G\u00fc\u00e7 Sistemleri Personeli (Seviye 5) Ulusal Yeterlili\u011fi Teorik S\u0131nav ba\u015fl\u0131\u011f\u0131 alt\u0131nda belirlenmi\u015f \u201cBilgi (BG)\u201d kontrol listesine g\u00f6re test sorular\u0131n\u0131n haz\u0131rlanmas\u0131 gerekti\u011fi dikkate al\u0131nmal\u0131d\u0131r. E\u011fer Ulusal Yeterlilik dosyas\u0131nda mevcut Mod\u00fcl i\u00e7eri\u011fine direkt hitap eden bir teorik s\u0131nav uygulamas\u0131 yoksa (\u00f6rne\u011fin Mod\u00fcl 1 ve Mod\u00fcl 3 i\u00e7in), bu durumdaki test sorular\u0131n\u0131n sadece mevcut mod\u00fcl i\u00e7in listelenmi\u015f \u00f6\u011frenme kazan\u0131mlar\u0131n\u0131 \u00f6l\u00e7ecek \u015fekilde geli\u015ftirilmesi \u00f6nerilmektedir. MOD\u00dcL 5 \u0130\u00c7\u0130N \u00d6RNEK TEST SINAVI SORULARI 4.1. ALT \u00d6\u011eRENME KAZANIMI-2.1 KAPSAMINDAKI TEST SORULARI BG1. Fotovoltaik g\u00fc\u00e7 sistemlerinin elektrik devre bile\u015fenlerini a\u00e7\u0131klar. Soru 1. Fotovoltaik g\u00fc\u00e7 sistemlerinde DC gerilimi AC gerilime \u00e7eviren bile\u015fen a\u015fa\u011f\u0131dakilerden hangisidir? a) Fotovoltaik panel b) Ka\u00e7ak ak\u0131m r\u00f6lesi c) Evirici d) Batarya Soru 2. Fotovoltaik g\u00fc\u00e7 sistemlerinde ters ak\u0131m sonucu panellerin zarar g\u00f6rmesini engelleyen devre eleman\u0131 a\u015fa\u011f\u0131dakilerden hangisidir? a) Evirici b) Bloklama diyotu c) \u015earj reg\u00fclat\u00f6r\u00fc d) Konekt\u00f6r Soru 3. A\u015fa\u011f\u0131dakilerden hangisi Fotovoltaik g\u00fc\u00e7 sistemlerinde kullan\u0131lan elektriksel devre bile\u015fenlerinden de\u011fildir? a) Vida b) Ak\u00fc c) Konekt\u00f6r d) Panel BG2. Fotovoltaik g\u00fc\u00e7 sistemi elektrik devre \u015femas\u0131n\u0131n i\u015flevini a\u00e7\u0131klar. Soru 4. Bir fotovoltaik g\u00fc\u00e7 sisteminde bulunan bile\u015fenlerin basit sembolleri kullan\u0131larak haz\u0131rlanarak grafiksel g\u00f6sterime ne ad verilir? a) Tek hat \u015femas\u0131 b) Kablo kesit analizi c) Ak\u0131m-gerilim e\u011frisi d) Montaj \u015femas\u0131 MOD\u00dcL 5 - 127","Soru 5. A\u015fa\u011f\u0131dakilerden hangisi tek hat \u015femas\u0131ndan yararlan\u0131larak bulunamaz? a) Montaj i\u00e7in kablo t\u00fcr\u00fc ve boyutlar\u0131 b) Sigorta, kesici, anahtar ve \u015falterler c) Evirici boyutlar\u0131 d) Fotovoltaik panel s\u0131cakl\u0131k katsay\u0131s\u0131 Soru 6. A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik g\u00fc\u00e7 sistemi montaj plan\u0131nda yer almaz? a) Ta\u015f\u0131y\u0131c\u0131 Sistem mekanik kurulum \u015femas\u0131 b) Panellerin ta\u015f\u0131y\u0131c\u0131 sistem \u00fczerine kurulum \u015femas\u0131 c) Fotovoltaik G\u00fc\u00e7 Bile\u015fenlerinin istif edilme y\u00f6ntemleri d) Kablo yerle\u015fim g\u00fczergahlar\u0131n\u0131n g\u00f6sterimi BG3. Elektrik devre \u015femas\u0131na g\u00f6re montaj yap\u0131lacak yerlerin montaja uygunlu\u011funu kontrol s\u00fcrecini a\u00e7\u0131klar. Soru 7. Elektriksel bile\u015fenlerin montaj\u0131nda montaj yeriyle ilgili a\u015fa\u011f\u0131da verilen ifadelerden hangisi do\u011frudur? a) \u00c7at\u0131 tipi sistemlerde kablolar mutlaka boru i\u00e7erisine al\u0131nmal\u0131d\u0131r. b) Toprak kablo kanallar\u0131nda kablolar aras\u0131 mesafe en fazla 3 cm olmal\u0131d\u0131r. c) \u00c7ift s\u0131ra AC faz kablolar\u0131n\u0131n kablo kanal\u0131ndaki yerle\u015fimi rastgele yap\u0131labilir. d) Birden fazla katl\u0131 AC kablo yerle\u015fimlerinde katlar aras\u0131 en az 20 cm mesafe olmal\u0131d\u0131r. Soru 8. \u00c7at\u0131 tipi fotovoltaik g\u00fc\u00e7 sistemlerinde DC kablolar\u0131n montaj yerleri ile ilgili a\u015fa\u011f\u0131da verilenlerden hangisi yanl\u0131\u015ft\u0131r? a) \u00c7at\u0131 tipi sistemlerde g\u00fcne\u015f g\u00f6ren DC kablolar\u0131n g\u00fcne\u015ften koruma ad\u0131na \u00f6nlemler al\u0131nmal\u0131d\u0131r. b) Panel kablolar\u0131 panelin arka k\u0131sm\u0131na yap\u0131\u015ft\u0131r\u0131lmal\u0131d\u0131r. c) DC Kablolar\u0131n kablo kanallar\u0131nda \/ tavalar\u0131nda zarar g\u00f6rmemesi i\u00e7in izolasyon koruyucu y\u00f6ntemler yap\u0131lmal\u0131d\u0131r. d) DC kablolar\u0131n kablo tavalar\u0131ndan ta\u015f\u0131nmas\u0131nda kullan\u0131lan kablo tava kapaklar\u0131 kapal\u0131 tutulmal\u0131d\u0131r. Soru 9. Yer tipi fotovoltaik g\u00fc\u00e7 sistemlerinde kablolar\u0131n montaj yerleri ile ilgili a\u015fa\u011f\u0131da verilenlerden hangisi yanl\u0131\u015ft\u0131r? a) Yer tipi sistemlerde g\u00fcne\u015f g\u00f6ren dc kablolar\u0131n g\u00fcne\u015ften koruma ad\u0131na \u00f6nlemler al\u0131nmal\u0131d\u0131r. b) Panel kablolar\u0131 ba\u011flant\u0131s\u0131nda kablolar tamamen gerdirilerek, sarkma pay\u0131 b\u0131rak\u0131lmayarak ba\u011flanmal\u0131d\u0131r. c) DC Kablolar\u0131n kablo kanallar\u0131nda \/ tavalar\u0131nda zarar g\u00f6rmemesi i\u00e7in izolasyon koruyucu y\u00f6ntemler yap\u0131lmal\u0131d\u0131r. d) DC kablolar\u0131n kablo tavalar\u0131ndan ta\u015f\u0131nmas\u0131nda kullan\u0131lan kablo tava kapaklar\u0131 kapal\u0131 tutulmal\u0131d\u0131r. BG4. \u00c7al\u0131\u015fma sahas\u0131n\u0131n durumuna g\u00f6re elektriksel bile\u015fen montaj\u0131nda ekipmanlar\u0131 istif etme y\u00f6ntemlerini a\u00e7\u0131klar. Soru 10. Fotovoltaik panellerin istif edilmesi ve ta\u015f\u0131nmas\u0131 a\u015famalar\u0131nda yap\u0131lan uygulamalardan hangisi yanl\u0131\u015ft\u0131r? a) Panellerin ta\u015f\u0131nmas\u0131 esnas\u0131nda kablolar\u0131ndan ve ba\u011flant\u0131 kutular\u0131ndan tutulmamal\u0131d\u0131r. b) Panellerin istif edilmesi esnas\u0131nda cam y\u00fczeylerine bas\u0131lmamal\u0131d\u0131r. c) Panellerin ta\u015f\u0131nmas\u0131nda yal\u0131tkan eldiven kullan\u0131lmal\u0131d\u0131r. d) Panellerin istif edilmesi sonras\u0131 g\u00fcne\u015ften korumak i\u00e7in \u00fcst k\u0131s\u0131mdaki panelin cam y\u00fczeyi koruyucu boya ile boyanmal\u0131d\u0131r. MOD\u00dcL 5 - 128","Soru 11. Fotovoltaik panellerin istif edilmesi ve ta\u015f\u0131nmas\u0131 a\u015famalar\u0131nda yap\u0131lan uygulamalardan hangisi do\u011frudur? a) Panellerin istif edilmesi durumlar\u0131nda direkt olarak g\u00fcne\u015fe maruz b\u0131rak\u0131lmamal\u0131d\u0131r. b) Panellerin istif edilmesi durumlar\u0131nda birbiri aras\u0131nda 20 panele kadar seri olarak ba\u011flanmal\u0131d\u0131r. c) Panellerin ta\u015f\u0131nmas\u0131 durumlar\u0131nda panel kablolar\u0131 yerinden s\u00f6k\u00fclmelidir. d) Panellerin ta\u015f\u0131nmas\u0131 durumlar\u0131nda ba\u011flant\u0131 kutular\u0131 s\u00f6k\u00fclmelidir. Soru 12. Fotovoltaik panellerin ta\u015f\u0131nmas\u0131 a\u015famalar\u0131nda yap\u0131lan uygulamalardan hangisi do\u011frudur? a) Panellerin ta\u015f\u0131nmas\u0131nda paneller kablolar\u0131n tutarak cam y\u00fczeye dokunmadan ta\u015f\u0131nmas\u0131 esast\u0131r. b) Panellerin ta\u015f\u0131yanlar\u0131n metal e\u015fyalar kullanmamas\u0131 \u00f6nemlidir. c) Panellerin ta\u015f\u0131nmas\u0131 sadece i\u015f makinalar\u0131 ile yap\u0131lmal\u0131d\u0131r. d) Panellerin ta\u015f\u0131nmas\u0131 sadece gece yap\u0131lmal\u0131d\u0131r. BG5. Fotovoltaik sistemlerde kullan\u0131lan kablo \u00e7e\u015fitlerini s\u0131ralar. Soru 13. A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik sistemlerde kullan\u0131lan kablo t\u00fcrlerinden birisi de\u011fildir? a) NYY \u2013 YVV b) NAYY \u2013 YAVV c) N2XH d) L2TTYY Soru 14. Fotovoltaik sistemlerde yayg\u0131n kullan\u0131lan NYY \u2013 YVV kabloda hangi iletken bulunmaktad\u0131r? a) \u00c7inko b) Demir c) Bak\u0131r d) Al\u00fcminyum Soru 15. Panellerin ba\u011flant\u0131lar\u0131nda kullan\u0131lan kablolar hangi \u00f6zellikte olmal\u0131d\u0131r? a) D\u0131\u015f k\u0131l\u0131flar\u0131 UV korumal\u0131 olmal\u0131d\u0131r. b) Sadece Al\u00fcminyum \u00f6zellikte olmal\u0131d\u0131r. c) 100 metreden daha k\u0131sa hatlarda tek damarl\u0131 kablo, daha uzun hatlarda \u00e7ok damarl\u0131 kablo kullan\u0131lmal\u0131d\u0131r. d) Kablolar k\u0131rm\u0131z\u0131 renkte kullan\u0131lmal\u0131d\u0131r. E\u011fer ba\u015fka bir renk ise k\u0131rm\u0131z\u0131 renge boyanmal\u0131d\u0131r. BG6. Fotovoltaik sistemlerde kullan\u0131lan kablolar\u0131n elektriksel de\u011ferlerini a\u00e7\u0131klar. Soru 16. A\u015fa\u011f\u0131dakilerden hangisi kablo se\u00e7imi yap\u0131l\u0131rken g\u00f6z \u00f6n\u00fcne al\u0131nmas\u0131 gereken fakt\u00f6rlerden de\u011fildir? a) Toprakta ak\u0131m ta\u015f\u0131ma kapasitesi b) Havada ak\u0131m ta\u015f\u0131ma kapasitesi c) Kablo rengi d) \u0130letken DC direnci Soru 17. Fotovoltaik sistemlerde evirici \u00f6ncesi yayg\u0131n kullan\u0131lan NYY \u2013 YVV kabloda hangi iletken bulunmaktad\u0131r? a) \u00c7inko b) Demir c) Bak\u0131r d) Al\u00fcminyum Soru 18. Panellerin ba\u011flant\u0131lar\u0131nda kullan\u0131lan kablolar\u0131n kesiti a\u015fa\u011f\u0131dakilerden hangisi de\u011fildir. a) 4 mm2 b) 95 mm2 c) 180 mm2 d) 400 mm2 MOD\u00dcL 5 - 129","BG7. Elektrik devresi etiketlerini a\u00e7\u0131klar. Soru 19. A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik g\u00fc\u00e7 sistemleri elektrik devresinde kullan\u0131lan uyar\u0131 i\u015faret ve etiketlerinden de\u011fildir. a) Dikkat \u00d6l\u00fcm Tehlikesi b) Dikkat \u00c7ift Y\u00f6nl\u00fc Besleme c) Dikkat 1500 V Gerilim d) Dikkat Kaygan Zemin Soru 20. A\u015fa\u011f\u0131dakilerden hangisi evirici giri\u015fine ba\u011flanan dizi kablolar\u0131nda olmas\u0131 gereken etikettir? a) Dizi 1 (+) b) Evirici Faz 1 c) Evirici Faz A d) Dizi Faz C Soru 21. A\u015fa\u011f\u0131dakilerden hangisi evirici g\u00f6rebilece\u011fimiz uyar\u0131 i\u015faretlerinden de\u011fildir? a) Dikkat \u00c7ift Y\u00f6nl\u00fc Besleme b) Dikkat 1000V DC Gerilim c) Dikkat 1500 V DC Gerilim d) Sadece g\u00fcn \u0131\u015f\u0131\u011f\u0131nda m\u00fcdahale ediniz 4.2. ALT \u00d6\u011eRENME KAZANIMI-2.2 KAPSAMINDAKI TEST SORULARI BG8. Konekt\u00f6r ba\u011flant\u0131s\u0131n\u0131n do\u011fru yap\u0131lmamas\u0131 durumunda kar\u015f\u0131la\u015f\u0131lan problemleri \u00e7\u00f6z\u00fcm yollar\u0131yla a\u00e7\u0131klar. Soru 22. Konekt\u00f6r ba\u011flant\u0131s\u0131nda gev\u015feklik olmas\u0131 durumunda a\u015fa\u011f\u0131dakilerden hangisinin meydana gelmesi beklenmez? a) Daha verimli \u00fcretim sa\u011flan\u0131r b) \u0130zolasyon Ar\u0131zas\u0131 c) Is\u0131nma Ya\u015fan\u0131r d) Yanma tehlikesi ta\u015f\u0131r. Soru 23. Konekt\u00f6r ba\u011flant\u0131lar\u0131n\u0131n yap\u0131lmas\u0131 esnas\u0131nda pinlerin deformasyona (e\u011filme b\u00fck\u00fclme vb.) u\u011framas\u0131 durumunda a\u015fa\u011f\u0131dakilerden hangisi yap\u0131lmal\u0131d\u0131r? a) Yeni pinler kullan\u0131lmal\u0131d\u0131r. b) Pinler oldu\u011fu \u015fekliyle kullan\u0131lmal\u0131d\u0131r. c) Pinlere \u00e7inko banyosu yapt\u0131r\u0131lmal\u0131d\u0131r. d) Pinlerin hasar alan noktas\u0131 kesilip at\u0131lmal\u0131 ve geri kalan\u0131 kullan\u0131lmal\u0131d\u0131r. Soru 24. DC kablo ba\u011flant\u0131s\u0131 ile ilgili a\u015fa\u011f\u0131dakilerden hangisi do\u011frudur? a) Konekt\u00f6r hasar\u0131 durumunda ilgili ek noktas\u0131 bant ile yap\u0131\u015ft\u0131r\u0131lmal\u0131d\u0131r. b) Farkl\u0131 marka\/model di\u015fi ve erkek konekt\u00f6rler birlikte kullan\u0131lmamal\u0131d\u0131r. c) Konekt\u00f6rler suya ve g\u00fcne\u015fe olduk\u00e7a dayan\u0131kl\u0131d\u0131r ve sorun ya\u015famazlar. d) Konekt\u00f6rler \u00e7\u0131plak elle tutulabilir, elektriksel yal\u0131t\u0131m\u0131 olduk\u00e7a y\u00fcksektir. BG9. Elektrik devre \u015femas\u0131na ve montaj alan\u0131n\u0131n \u00f6zelli\u011fine g\u00f6re (\u00e7at\u0131, cephe ve benzeri uygulamalarda) izolasyon uygulamalar\u0131n\u0131 a\u00e7\u0131klar. Soru 25. Panel ve\/veya dizi kablolar\u0131n\u0131n tava giri\u015flerinde kullan\u0131lan izolasyon y\u00f6ntemlerini s\u0131ralay\u0131n\u0131z. Kablo ge\u00e7i\u015f rakoru, Spiral boru Soru 26. Tava i\u00e7erisinde tavan\u0131n keskin kenarlar\u0131na gelebilecek yerlerde kullan\u0131lan izolasyon malzemelerini s\u0131ralay\u0131n\u0131z. EPDM bant, kau\u00e7uk, fitil uygulamalar\u0131 MOD\u00dcL 5 - 130","Soru 27. Kablolarda d\u0131\u015f izolasyon k\u0131l\u0131f\u0131na uygulanan antitermit kaplaman\u0131n amac\u0131 nedir? a) Kemirgen hasar\u0131n\u0131 \u00f6nleme b) Topraklama direncini azaltma c) Y\u0131ld\u0131r\u0131m koruma d) Gerilim d\u00fc\u015f\u00fcm\u00fcn\u00fc \u00f6nleme 4.3. ALT \u00d6\u011eRENME KAZANIMI-2.3 KAPSAMINDAKI TEST SORULARI BG10. Panel dizilerinin gerilim seviyesini a\u00e7\u0131klar. Soru 28. Seri ba\u011fl\u0131 birden fazla panelden olu\u015fan bir panel dizisi ile ilgili a\u015fa\u011f\u0131dakilerden hangisi do\u011frudur? a) Dizi gerilimi tek bir panelin geriliminden azd\u0131r. b) Dizi ak\u0131m\u0131 her bir panelden ge\u00e7en ak\u0131mlar\u0131n toplam\u0131na e\u015fittir. c) Dizi gerilimi her bir panelin \u00fczerindeki gerilimlerin toplam\u0131na e\u015fittir. d) Dizi ak\u0131m\u0131 dizi geriliminden ba\u011f\u0131ms\u0131zd\u0131r. BG11. Panel dizilerinin gerilim seviyesi \u00f6l\u00e7\u00fcm sonucuna g\u00f6re uygulayaca\u011f\u0131 ad\u0131mlar\u0131 a\u00e7\u0131klar . Soru 29. A\u015fa\u011f\u0131dakilerden hangisi panel dizilerinin gerilim seviyesi \u00f6l\u00e7\u00fcm\u00fc sonucu beklenen de\u011ferin alt\u0131nda kal\u0131rsa yap\u0131lmas\u0131 gereken kontrollerden birisi de\u011fildir? a) Konekt\u00f6r ba\u011flant\u0131lar\u0131n\u0131 kontrol etmek b) \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n ayarlar\u0131n\u0131 oldu\u011funu kontrol etmek c) Panellerin \u00fczerinde g\u00f6lgelenme olup olmad\u0131\u011f\u0131n\u0131 kontrol etmek d) \u015eebeke frekans\u0131n\u0131 kontrol etmek BG12. Panel dizileri polaritesini tespit etme y\u00f6ntemini a\u00e7\u0131klar. Soru 30. DC kablolar\u0131n\u0131n polaritesi ile ilgili a\u015fa\u011f\u0131dakilerden hangisi yanl\u0131\u015ft\u0131r? a) Polaritede gerilim \u00f6l\u00e7\u00fcm\u00fc yap\u0131l\u0131r ve sonu\u00e7 \u201c+\u201d de\u011ferde ise \u00f6l\u00e7\u00fc aletinin + referans\u0131na u\u00e7 kablonun \u201c- \u201cucudur. b) Polaritede gerilim \u00f6l\u00e7\u00fcm\u00fc yap\u0131l\u0131r ve sonu\u00e7 \u201c+\u201d de\u011ferde ise \u00f6l\u00e7\u00fc aletinin + referans\u0131na u\u00e7 kablonun \u201cn\u00f6tr \u201cucudur. c) Polaritede gerilim \u00f6l\u00e7\u00fcm\u00fc yap\u0131l\u0131r ve sonu\u00e7 \u201c+\u201d de\u011ferde ise \u00f6l\u00e7\u00fc aletinin + referans\u0131na u\u00e7 kablonun \u201c+ \u201cucudur. d) Polaritede gerilim \u00f6l\u00e7\u00fcm\u00fc yap\u0131l\u0131r ve sonu\u00e7 \u201c+\u201d de\u011ferde ise \u00f6l\u00e7\u00fc aletinin + referans\u0131na u\u00e7 kablonun \u201cfaz 2\u201cucudur. BG13. Polaritenin yanl\u0131\u015f i\u015faretlenmesinin do\u011furaca\u011f\u0131 sonu\u00e7lar\u0131 a\u00e7\u0131klar. Soru 31. DC kablolar\u0131n\u0131n polaritesinin yanl\u0131\u015f belirlenmesi ile ilgili ortaya \u00e7\u0131kacak sonu\u00e7lardan hangisi a\u015fa\u011f\u0131da do\u011fru verilmi\u015ftir? a) Eviriciye yanl\u0131\u015f polarite ile ba\u011flanan dizi y\u00fcksek verimde \u00e7al\u0131\u015facakt\u0131r. b) Polaritesi yanl\u0131\u015f belirlenen dizi gerilimi eviriciye ba\u011flan\u0131rsa, ilgili dizi gerilimi 220 V \u2018a d\u00fc\u015fer. c) Polaritenin yanl\u0131\u015f belirlenmesi ile eviriciye ba\u011flanan diziler gece \u00e7al\u0131\u015f\u0131r, g\u00fcnd\u00fcz \u00e7al\u0131\u015fmaz. d) Polaritesi yanl\u0131\u015f olan diziler, eviricilere ba\u011flan\u0131rsa, eviricilere zarar verebilir. BG14. Konekt\u00f6r ba\u011flant\u0131lar\u0131n\u0131n a\u00e7\u0131k devre u\u00e7lar\u0131nda kopukluk olmas\u0131 durumunda kar\u015f\u0131la\u015f\u0131lacak problemleri ve \u00e7\u00f6z\u00fcm yollar\u0131n\u0131 a\u00e7\u0131klar. Soru 32. Dizi kablo hatt\u0131nda kopukluk olmas\u0131 durumunda a\u015fa\u011f\u0131dakilerden hangisi yap\u0131lmal\u0131d\u0131r? a) Dizi kablosunun evirici giri\u015finde kablolar ters polarite ile ba\u011flan\u0131r. b) A\u00e7\u0131k devre gerilimi \u00f6l\u00e7\u00fcl\u00fcr ve eksik gerilim de\u011feri kadar masaya panel eklenir. c) Dizi hatt\u0131ndaki kopuklu\u011fun panel ba\u011flant\u0131lar\u0131 aras\u0131nda olup olmad\u0131\u011f\u0131na dair kontroller yap\u0131l\u0131r. MOD\u00dcL 5 - 131","d) Dizi kablosundaki kopukluk bulunur ve izole bant ile onar\u0131l\u0131p \u00e7al\u0131\u015fmas\u0131 sa\u011flan\u0131r. 4.4. ALT \u00d6\u011eRENME KAZANIMI-2.4 KAPSAMINDAKI TEST SORULARI BG15. Eviriciyi tan\u0131mlayarak \u00e7al\u0131\u015fma prensibini a\u00e7\u0131klar. Soru 33. Fotovoltaik panel taraf\u0131ndan \u00fcretilen do\u011fru ak\u0131m gerilimi alternatif ak\u0131m gerilime \u00e7eviren cihaz a\u015fa\u011f\u0131dakilerden hangisidir? a) \u015earj reg\u00fclat\u00f6r\u00fc b) Evirici c) Parafudr d) Ka\u00e7ak ak\u0131m r\u00f6lesi Soru 34. \u015eebekeden ba\u011f\u0131ms\u0131z evsel bir fotovoltaik sistemde evirici g\u00fcc\u00fc ayn\u0131 anda \u00e7al\u0131\u015faca\u011f\u0131 d\u00fc\u015f\u00fcn\u00fclen cihazlar\u0131n anl\u0131k toplam g\u00fcc\u00fcnden _______ olmal\u0131d\u0131r. a) E\u015fit, b) D\u00fc\u015f\u00fck c) Y\u00fcksek d) \u00d6nemli de\u011fildir Soru 35. Eviriciler \u00e7\u0131k\u0131\u015f dalga \u015fekilleri bak\u0131m\u0131ndan ikiye ayr\u0131l\u0131r: _________ eviriciler ve __________________ eviriciler. a) Tam sin\u00fcs b) Senkron c) Modifiye sin\u00fcs d) Asenkron BG16. Topraklama hatt\u0131 montaj\u0131n\u0131 a\u00e7\u0131klar. Soru 36. Koruma topraklama direncinin 10 ohm\u2019dan _______ olmas\u0131 gerekir. Yanl\u0131\u015f. Koruma topraklama direncinin 10 ohm\u2019dan k\u00fc\u00e7\u00fck olmas\u0131 gerekir. Soru 37. Birden fazla topraklama \u00e7ubu\u011funun \u00e7ak\u0131ld\u0131\u011f\u0131 durumlarda iki \u00e7ubuk aras\u0131ndaki mesafe \u00e7ubuk boyunun en az ka\u00e7 kat\u0131 olmal\u0131d\u0131r? a) 10 b) 0.5 c) 2 d) 4 Soru 38. Topraklama \u00e7ubuklar\u0131 ini\u015f iletkenleri ile toprak y\u00fczeyinin en az _______ alt\u0131nda birbirine ba\u011flanmal\u0131d\u0131r a) 10-15 cm b) 100-150 cm c) 5-10 cm d) 50-75 cm Soru 39. G\u00fcne\u015f panelleri, montaj yeri \u00f6zelli\u011fine g\u00f6re hangi t\u00fcr iletkenler ile topraklan\u0131r? a) G\u00fcm\u00fc\u015f b) Aluminyum c) \u00c7elik d) Bak\u0131r MOD\u00dcL 5 - 132","BG17. Topraklama y\u00f6ntemlerini a\u00e7\u0131klar. Soru 40. \u0130nsanlar\u0131 tehlikeli dokunma gerilimlerine kar\u015f\u0131 korumak i\u00e7in i\u015fletme ara\u00e7lar\u0131n\u0131n aktif olmayan k\u0131s\u0131mlar\u0131n\u0131n topraklanmas\u0131na ______ topraklamas\u0131 denir. a) Fonksiyonel b) Y\u0131ld\u0131r\u0131m c) Koruma d) \u0130\u015fletme Soru 41. Tesisin normal i\u015fletilmesi i\u00e7in i\u015fletme ak\u0131m devresinin topraklanmas\u0131na______ topraklamas\u0131 denir. a) Fonksiyonel b) Y\u0131ld\u0131r\u0131m c) Koruma d) \u0130\u015fletme Soru 42. Bir ileti\u015fim tesisinin veya bir i\u015fletme eleman\u0131n\u0131n istenen fonksiyonu yerine getirmesi amac\u0131yla yap\u0131lan topraklamaya ______ topraklamas\u0131 denir. a) Fonksiyonel b) Y\u0131ld\u0131r\u0131m c) Koruma d) \u0130\u015fletme Soru 43. Y\u0131ld\u0131r\u0131m d\u00fc\u015fmesi durumunda i\u015fletme gere\u011fi gerilim alt\u0131nda bulunan iletkenlere atlamalar\u0131 geni\u015f \u00f6l\u00e7\u00fcde \u00f6nlemek ve y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131 topra\u011fa iletmek i\u00e7in i\u015fletme ak\u0131m devresine ili\u015fkin olmayan iletken b\u00f6l\u00fcmlerin topraklanmas\u0131na ______ topraklamas\u0131 denir. a) Fonksiyonel b) Y\u0131ld\u0131r\u0131m c) Koruma d) \u0130\u015fletme BG18. Topraklaman\u0131n \u00f6nemini a\u00e7\u0131klar. Soru 44. Topraklama sistemleri ile ilgili a\u015fa\u011f\u0131daki ifadelerden hangisi yanl\u0131\u015ft\u0131r? a) Topraklaman\u0131n amac\u0131, elektrikli al\u0131c\u0131lar\u0131 kullananlar\u0131n can g\u00fcvenli\u011fini sa\u011flamak ve cihazlar\u0131n zarar g\u00f6rmesini \u00f6nlemektir. b) B\u00fct\u00fcn elektrik makinelerinin g\u00f6vdeleri, borular\u0131n madeni k\u0131s\u0131mlar\u0131, tablo ve benzerlerinin metal k\u0131s\u0131mlar\u0131 topraklanmal\u0131d\u0131r. c) Y\u0131ld\u0131r\u0131m korumas\u0131 olan tesislerde topraklama gerekli de\u011fildir. d) Beton temeline g\u00f6m\u00fclen \u00e7elik ve \u00e7elik kaz\u0131klar veya di\u011fer topraklay\u0131c\u0131lar topraklama tesisinin bir k\u0131sm\u0131 olarak kullan\u0131labilir. BG19. Y\u0131ld\u0131r\u0131m koruma elemanlar\u0131n\u0131 a\u00e7\u0131klar. Soru 45. Yakalama ucu, indirme iletkeni ve topraklama sistemlerinden olu\u015fan sisteme \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.. denir. Soru 46. D\u0131\u015f YKS\u2019nin, y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131 yakalama ucu sisteminden, topraklama sistemine ge\u00e7irmek \u00fczere kullan\u0131lan b\u00f6l\u00fcm\u00fcne \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.. denir. Soru 47. Korunan hacmin i\u00e7inde, y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131n elektromanyetik etkilerini azaltmak \u00fczere d\u0131\u015f YKS i\u00e7in verilenlere ek olarak al\u0131nacak t\u00fcm \u00f6nlemlere \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.. denir. MOD\u00dcL 5 - 133","BG20. Y\u0131ld\u0131r\u0131m koruma elemanlar\u0131n\u0131n montaj s\u00fcre\u00e7lerini a\u00e7\u0131klar. Soru 48. Kafes y\u00f6nteminde yakalama ucu iletkenleri olabilecek en k\u0131sa ve d\u00fcz yollar\u0131 izlemelidir. (Do\u011fru \/ Yanl\u0131\u015f ) Soru 49. Yuvarlanan k\u00fcre y\u00f6ntemi karma\u015f\u0131k geometrili yap\u0131lar i\u00e7in daha uygundur. (Do\u011fru \/ Yanl\u0131\u015f ) Soru 50. Kafes y\u00f6ntemi genel ama\u00e7lar i\u00e7in olup \u00f6zellikle d\u00fcz y\u00fczeylerin korunmas\u0131 i\u00e7in uygundur. (Do\u011fru \/ Yanl\u0131\u015f ) BG21. Y\u0131ld\u0131r\u0131m koruma sisteminin gereklili\u011fini a\u00e7\u0131klar. Soru 51. Y\u0131ld\u0131r\u0131m etkisi ile panellerde \u015fok etkisinin yard\u0131m\u0131yla verim artar (Do\u011fru \/ Yanl\u0131\u015f ) Soru 52. Y\u0131ld\u0131r\u0131m etkisi ile eviricilerde \u015fok etkisinin yard\u0131m\u0131yla verim artar (Do\u011fru \/ Yanl\u0131\u015f ) Soru 53. Y\u0131ld\u0131r\u0131m etkisi ile data hatlar\u0131nda herhangi bir olumsuz durum ya\u015fanmaz (Do\u011fru\/Yanl\u0131\u015f) BG22. Eviricilerin montaj ad\u0131mlar\u0131n\u0131 a\u00e7\u0131klar. BG23. Evirici ile fotovoltaik dizi aras\u0131ndaki kablo ba\u011flant\u0131s\u0131n\u0131n kontrol s\u00fcrecini a\u00e7\u0131klar. Soru 54. A\u015fa\u011f\u0131dakilerden hangisi dizi kablolar\u0131n\u0131n evirici k\u0131sm\u0131nda ba\u011flant\u0131lar\u0131 \u00f6ncesi yap\u0131lmas\u0131 gereken testlerden de\u011fildir? a) Dizi A\u00e7\u0131k Devre Gerilim \u00d6l\u00e7\u00fcm\u00fc b) Dizi \u0130zolasyon Testi c) Dizi Polarite \u00d6l\u00e7\u00fcm\u00fc d) Dizi Verimlilik \u00d6l\u00e7\u00fcm\u00fc BG24. G\u00fcne\u015f enerjisi santrali (GES) panosunu bile\u015fenleriyle a\u00e7\u0131klar. Soru 55. A\u015fa\u011f\u0131dakilerden hangisi GES panosu bile\u015fenlerinden de\u011fildir. a) Termik Manyetik \u015ealter b) Ka\u00e7ak Ak\u0131m Koruma R\u00f6lesi c) Ak\u0131m Trafosu d) Dizi Sigorta Kutusu BG25. G\u00fcne\u015f enerjisi santrali (GES) panosunun \u00e7al\u0131\u015fma prensibini a\u00e7\u0131klar. Soru 56. A\u015fa\u011f\u0131daki ifadelerden hangisi GES panosu \u00e7al\u0131\u015fmas\u0131n\u0131 yap\u0131s\u0131n\u0131 a\u00e7\u0131klar. a) Eviricilerden gelen AC ak\u0131m ve Gerilimin koruma elemanlar\u0131ndan ge\u00e7erek transformat\u00f6r k\u0131sm\u0131na aktar\u0131lmas\u0131nda kullan\u0131lan bir birimdir. b) Dizilerden gelen DC ak\u0131m ve Gerilimin Eviricilere aktar\u0131m\u0131nda kullan\u0131lan bir birimdir. c) Panellerden gelen AC ak\u0131m ve gerilimin eviricilere aktar\u0131lmas\u0131n\u0131 sa\u011flayan bir birimdir. d) Eviricilerden panellere giden AC ak\u0131m ve gerilimin aktar\u0131lmas\u0131n\u0131 sa\u011flayan bir birimdir. BG26. G\u00fcne\u015f enerjisi santrali (GES) panosu ve bile\u015fenlerinin kontrol s\u00fcrecini a\u00e7\u0131klar. Soru 57. A\u015fa\u011f\u0131dakilerden hangisi GES panosunda yap\u0131lmas\u0131 gerekli kontrollerden de\u011fildir? a) Elektrol\u00fcminesans testi b) Termal Is\u0131 Testi c) Havaland\u0131rma Sirkulasyon Kontrol\u00fc d) Ba\u011flant\u0131 Tork Kontrol\u00fc MOD\u00dcL 5 - 134","BG27. Enerji depolama sisteminin ekipmanlar\u0131n\u0131 listeler. Soru 58. A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik g\u00fc\u00e7 sistemlerinden olu\u015fan enerji depolamal\u0131 sistemlerde bulunan ekipmanlardan biri de\u011fildir? a) Batarya Grubu b) Evirici c) Solar Panel d) T\u00fcrbin BG28. Enerji depolama sisteminin montaj i\u015flem basamaklar\u0131n\u0131 s\u0131ralar. Soru 59. Fotovoltaik g\u00fc\u00e7 sistemlerinden olu\u015fan enerji depolamal\u0131 sistemlerde bulunan ak\u00fc gruplar\u0131n\u0131n kapasitelerinin artt\u0131r\u0131lmas\u0131 i\u00e7in yap\u0131lan ba\u011flant\u0131ya \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026. denir. 4.5. ALT \u00d6\u011eRENME KAZANIMI-2.5 KAPSAMINDAKI TEST SORULARI BG29. Topraklama direncini a\u00e7\u0131klar. Soru 60) \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026 topra\u011f\u0131n elektrik ak\u0131m\u0131n\u0131 ge\u00e7irebilmesi s\u0131ras\u0131nda g\u00f6sterdi\u011fi tepkidir. BG30. Topraklama direnci \u00e7e\u015fitlerini a\u00e7\u0131klar. Soru 61.. \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026.. insanlar\u0131 tehlikeli dokunma gerilimlerine kar\u015f\u0131 korumak i\u00e7in i\u015fletme ara\u00e7lar\u0131n\u0131n aktif olmayan k\u0131s\u0131mlar\u0131n\u0131n topraklanmas\u0131d\u0131r. BG31. Topraklama direnci \u00f6l\u00e7\u00fcm s\u00fcrecini kullan\u0131lan ekipmanlarla a\u00e7\u0131klar. Soru 62. Topraklama \u00f6l\u00e7\u00fcm\u00fcn\u00fcn temel prensibinin anlat\u0131ld\u0131\u011f\u0131 a\u015fa\u011f\u0131daki ifadede bo\u015fluklara hangileri gelmelidir. E: Toprak elektrodu C: Ak\u0131m elektrodu P: Potansiyel elektrodu Kullan\u0131c\u0131lar, \u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026\u2026 ve \u2026\u2026\u2026\u2026\u2026\u2026\u2026. elektrotlar\u0131na sabit ak\u0131m uygulayarak \u2026\u2026\u2026\u2026\u2026\u2026. ile \u2026\u2026\u2026\u2026\u2026\u2026. aras\u0131ndaki potansiyel fark\u0131 elde etmektedir. Cihaz, V\/I hesab\u0131n\u0131n yap\u0131lmas\u0131 ile toprak direnci olan R\u2019yi vermektedir. BG32. Topraklama direncinin belirtilen de\u011ferin \u00fcst\u00fcnde olmas\u0131 durumunda kar\u015f\u0131la\u015f\u0131lacak problemleri \u00e7\u00f6z\u00fcm yollar\u0131yla a\u00e7\u0131klar. Soru 63. Topraklama direncinin belirtilen de\u011ferin \u00fcst\u00fcnde olmas\u0131 durumunda a\u015fa\u011f\u0131dakilerden hangisi yap\u0131lmal\u0131d\u0131r? a) Topraklama sistemi g\u00fc\u00e7lendirilmelidir. b) Topraklama sistemi de\u011fi\u015ftirilmelidir. c) Topraklama elektrotlar\u0131 y\u00fczeye yak\u0131n yerlere konumland\u0131r\u0131lmal\u0131d\u0131r. d) Topraklama sisteminin oldu\u011fu alanda en az 1 d\u00f6n\u00fcm alana humuslu toprak d\u00f6k\u00fclmelidir. 4.6. ALT \u00d6\u011eRENME KAZANIMI-2.6 KAPSAMINDAKI TEST SORULARI BG33. Faz\/polarite ili\u015fkisi ve toprak empedans\u0131 kontrol sonucunun uygun olmamas\u0131 durumunda kar\u015f\u0131la\u015f\u0131lacak problemleri \u00e7\u00f6z\u00fcm yollar\u0131yla a\u00e7\u0131klar. MOD\u00dcL 5 - 135","Soru 64. Polaritesi yanl\u0131\u015f belirlenen ve eviriciye yanl\u0131\u015f ba\u011flant\u0131 yap\u0131lan dizi kablolar\u0131 sebebiyle a\u015fa\u011f\u0131daki durumlardan hangisinin ya\u015fanmas\u0131 beklenir. a) Evirici ters polarite hatas\u0131 verebilir, ilgili dizi \u00e7al\u0131\u015fmayacakt\u0131r. b) Evirici herhangi bir hata vermez ve ilgili dizi \u00e7al\u0131\u015f\u0131r. c) Evirici herhangi bir hata vermez ve ilgili dizi 2 kat verimli \u00e7al\u0131\u015f\u0131r. d) \u0130lgili dizinin verimi yar\u0131 yar\u0131ya d\u00fc\u015fer ancak evirici \u00e7al\u0131\u015f\u0131r. BG34. Eviriciye ba\u011flanacak kablolarda toprak ka\u00e7a\u011f\u0131 olmas\u0131 durumunda kar\u015f\u0131la\u015f\u0131lacak problemleri \u00e7\u00f6z\u00fcm yollar\u0131yla a\u00e7\u0131klar. Soru 65. DC Toprak ka\u00e7a\u011f\u0131 uyar\u0131s\u0131 veren bir eviricide yap\u0131lmas\u0131 gereken \u00f6l\u00e7\u00fcm ve eviricinin devreye girmesi i\u00e7in yap\u0131lmas\u0131 gereken ge\u00e7ici \u00e7\u00f6z\u00fcm metodu nedir? a) DC Kablolarda izolasyon \u00f6l\u00e7\u00fcm\u00fc \/ ilgili sorunlu dizinin eviriciye ba\u011flanmamas\u0131 b) AC Kablolarda Faz s\u0131ras\u0131 \u00f6l\u00e7\u00fcm\u00fc \/ \u0130lgili faz s\u0131ras\u0131n\u0131n do\u011fru girilmesi c) DC Kablolarda IV E\u011frisi (IV-curve) \u00f6l\u00e7\u00fcm\u00fc \/ Verimi d\u00fc\u015f\u00fck dizinin eviriciye ba\u011flanmamas\u0131 d) AC Kablolarda \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc \/ \u0130lgili izolasyon ar\u0131zas\u0131na sahip faz kablosunun eviriciye ba\u011flanmamas\u0131 4.7 ALT \u00d6\u011eRENME KAZANIMI-2.7 KAPSAMINDAKI TEST SORULARI BG35. Elektriksel bile\u015fenlerin montaj\u0131n\u0131n kontrol s\u00fcrecini a\u00e7\u0131klar. Soru 66. Solar panellerin seri \/ paralel ba\u011flant\u0131s\u0131n\u0131n ard\u0131ndan olu\u015fturan dizilerin eviricilere ba\u011flanmadan \u00f6nce yap\u0131lmas\u0131 gereken g\u00fcvenlik testlerinden hangileri a\u015fa\u011f\u0131da do\u011fru verilmi\u015ftir. a) Polarite \u00d6l\u00e7\u00fcm\u00fc \/ \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc \/ Voc-Isc \u00d6l\u00e7\u00fcm\u00fc b) Polarite \u00d6l\u00e7\u00fcm\u00fc \/ Verimlilik \u00d6l\u00e7\u00fcm\u00fc \/ Termal \u00d6l\u00e7\u00fcm c) Faz S\u0131ras\u0131 \u00d6l\u00e7\u00fcm\u00fc \/ EL Testi \/ \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc d) \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc \/ Voc-Isc \u00d6l\u00e7\u00fcm\u00fc \/ Termal \u00d6l\u00e7\u00fcm BG36. Uyar\u0131 levhalar\u0131n\u0131n yerle\u015ftirilece\u011fi yerleri a\u00e7\u0131klar. Soru 67. Uyar\u0131 i\u015faretlerinin yerle\u015ftirilmesi gereken yerleri listeleyiniz Soru 68. A\u015fa\u011f\u0131dakilerden hangisi evirici \u00fczerinden bulunmas\u0131 gereken uyar\u0131 i\u015faret ve levhalar\u0131ndan de\u011fildir? a) Dikkat \u00c7ift Y\u00f6nl\u00fc Besleme b) Dikkat \u00d6l\u00fcm Tehlikesi c) Dikkat DC Gerilim d) Dikkat Kaygan Zemin MOD\u00dcL 5 - 136","MOD\u00dcL 5 - CEVAP ANAHTARI 1) C 2) B 3) A 4) A 5) D 6) C 7) D 8) B 9) B 10) D 11) A 12) A 13) D 14) C 15) A 16) C 17) C 18) D 19) D 20) A 21) D 22) A 23) A 24) B 25) Kablo ge\u00e7i\u015f rakoru, Spiral boru 26) EPDM bant, kau\u00e7uk, fitil uygulamalar\u0131 27) A 28) C 29) D 30) C 31) D 32) C 33) B 34) C 35) A ve C 36) K\u00fc\u00e7\u00fck 37) C 38) A 39) D 40) C 41) D 42) A 43) B 44) C 45) D\u0131\u015f Y\u0131ld\u0131r\u0131ml\u0131k Korunma Sistemi 46) \u0130ndirme \u0130letkeni 47) \u0130\u00e7 Y\u0131ld\u0131r\u0131ml\u0131k Korunma Sistemi 48) Do\u011fru 49) Do\u011fru 50) Do\u011fru MOD\u00dcL 5 - 137","51) Yanl\u0131\u015f 52) Yanl\u0131\u015f 53) Yanl\u0131\u015f 54) D 55) D 56) A 57) A 58) D 59) Paralel ba\u011flant\u0131 60) Topraklama direnci 61) Koruma Topraklamas\u0131 62) E ve C, E ile P 63) A 64) A 65) A 66) A 67) GES tesis giri\u015fi, evirici, panolar, kablo kanal ve ta\u015f\u0131ma g\u00fczergahlar\u0131, kablo tavalar\u0131, batarya odas\u0131 68) D MOD\u00dcL 5 - 138","KONU 5 YETERL\u0130L\u0130K KONTROL L\u0130STES\u0130 Her bir mod\u00fcldeki yeterlilik kontrol k\u0131sm\u0131; Fotovoltaik G\u00fc\u00e7 Sistemleri Personeli (Seviye 5) Ulusal Standart Dosyas\u0131nda Listelenen Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri dikkate al\u0131narak haz\u0131rlanm\u0131\u015ft\u0131r. E\u011fitmenlerin ve \u00d6\u011frencilerin bu k\u0131s\u0131mda belirtilen kontrol listesine g\u00f6re e\u011fitim ve \u00f6\u011frenme yeterlili\u011fini de\u011ferlendirmeleri \u00f6nerilmektedir. 5.1. Yeterlilik Kontrol Listesi-1 (Fotovoltaik g\u00fc\u00e7 sistemleri elektrik montaj\u0131 i\u00e7in haz\u0131rl\u0131k yapmak) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.1.1 Fotovoltaik g\u00fc\u00e7 sistemleri elektrik devre \u015femas\u0131n\u0131 1. Ak\u00fcl\u00fc sistemler bile\u015fenlerinin inceler. montaj\u0131 D.1.2 Elektrik devre \u015femas\u0131na g\u00f6re montaj yap\u0131lacak 2. Alan t\u00fcr\u00fcne g\u00f6re istif yapma yerlerin montaja uygunlu\u011funu kontrol eder. 3. A\u015f\u0131r\u0131 ak\u0131m ve a\u015f\u0131r\u0131 gerilim D.1.3 Elektrik devre \u015femas\u0131 kapsam\u0131nda kullan\u0131lmas\u0131 ve 4. Denetleyici ve kesici montaj\u0131 montaj\u0131n\u0131n yap\u0131lmas\u0131 geren ekipmanlar\u0131n, makine 5. Ekip y\u00f6netimi 6. El aletleri kullanma ve cihazlar\u0131n uygunlu\u011funu, fiziksel sa\u011flaml\u0131\u011f\u0131n\u0131, 7. Elektrik say\u0131s\u0131n\u0131 ve \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 kontrol eder. D.1.4 Kontrol\u00fcn\u00fc ger\u00e7ekle\u015ftirdi\u011fi makine ve ekipmanlar\u0131n 8. Elektrik devre \u015femas\u0131 okuma 9. Elektrik pano montaj\u0131 da\u011f\u0131t\u0131m\u0131n\u0131 yapar. D.1.5 Malzemelerin ve par\u00e7alar\u0131n hasar g\u00f6rmemesi i\u00e7in 10. Elektriksel bile\u015fen montaj kontrol\u00fc talimatta belirtilen \u00f6nlemlerin al\u0131nmas\u0131n\u0131 sa\u011flar. 11. Elektriksel de\u011fer \u00f6l\u00e7me D.1.6 Malzemelerin ve par\u00e7alar\u0131n istifini \u00e7al\u0131\u015fma 12. Etiketleme sahas\u0131n\u0131n durumunu (arazi, \u00e7at\u0131, cephe ve benzeri) 13. Evirici montaj\u0131 D.1.7 g\u00f6zeterek yap\u0131lmas\u0131n\u0131 sa\u011flar. 14. Faz\/polarite ili\u015fkileri ve kontrol\u00fc D.1.8 15. Fotovoltaik sistemlerin Yapt\u0131\u011f\u0131 kontrol sonu\u00e7lar\u0131na g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 elektriksel bile\u015fen montaj\u0131n\u0131 yapma uygunsuzluklar\u0131n d\u00fczeltilmesini sa\u011flar. Elektrik devre \u015femas\u0131na uygun olarak kablolar\u0131 ve montaj\u0131n\u0131 yapaca\u011f\u0131 sistem bile\u015fenlerinin (evirici, ak\u00fc ve benzeri) etiketlenmesini sa\u011flar. 5.2. Yeterlilik Kontrol Listesi-2 (Evirici montaj\u0131 \u00f6ncesi elektriksel bile\u015fenlerin montaj\u0131n\u0131n yap\u0131lmas\u0131n\u0131 sa\u011flamak) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.2.1 Paneller aras\u0131nda konekt\u00f6r ba\u011flant\u0131s\u0131n\u0131n montaj 16. G\u00fcne\u015f enerjisinden elektrik D.2.2 plan\u0131na g\u00f6re yap\u0131lmas\u0131n\u0131 sa\u011flar. \u00fcretimi Konekt\u00f6r ba\u011flant\u0131s\u0131n\u0131n sarkan k\u0131s\u0131mlar\u0131n\u0131n uygun 17. \u0130\u015f formlar\u0131 doldurma ve kay\u0131t malzeme (klemens, kelep\u00e7e ve benzeri) ile toplanmas\u0131n\u0131 sa\u011flar. tutma 18. \u0130\u015faretleme yapma 19. \u0130zolasyon \u00e7e\u015fitleri ve D.2.3 Elektrik devre \u015femas\u0131nda belirtilen izolasyon uygulamas\u0131 20. Kablo \u00e7ekimi yapma uygulamalar\u0131n\u0131n (\u00e7at\u0131, cephe ve benzeri 21. Kablo \u00e7e\u015fitleri uygulamalarda) talimata g\u00f6re yap\u0131lmas\u0131n\u0131 sa\u011flar. 22. Konekt\u00f6r ba\u011flant\u0131s\u0131 yapma D.2.4 Kablo \u00e7ekimi i\u00e7in talimatta belirtilen gerekli \u00f6n 23. Koruma cihazlar\u0131n\u0131n montaj\u0131 D.2.5 haz\u0131rl\u0131klar\u0131n (k\u0131lavuz, makara ve benzeri) yap\u0131lmas\u0131n\u0131 sa\u011flar. 24. Malzeme \u00e7e\u015fitleri ve \u00f6zellikleri Elektrik kablo tavalar\u0131n\u0131n veya kanallar\u0131n\u0131n kablolara zarar vermemesi i\u00e7in montaj plan\u0131nda belirtilen 25. Malzeme koruma uygulamalar\u0131n yap\u0131lmas\u0131n\u0131 sa\u011flar. 26. Malzeme ve ekipman kontrol\u00fc 27. Genel matematik MOD\u00dcL 5 - 139","D.2.6 Kablolar\u0131n tip ve elektriksel de\u011ferlerine dikkat 28. Mesleki terim D.2.7 ederek, montaj plan\u0131nda belirtilen kablo 29. Montaj alan\u0131 kontrol\u00fc g\u00fczergahlar\u0131na g\u00f6re kablolar\u0131 talimata ve etiketlemeye uygun olarak yerle\u015ftirilmesini sa\u011flar. Kablo u\u00e7lar\u0131na konekt\u00f6rlerin talimata uygun olarak tak\u0131lmas\u0131n\u0131 sa\u011flar. 5.3. Yeterlilik Kontrol Listesi-3 (Panel dizilerinin elektriksel de\u011ferlerini \u00f6l\u00e7mek) Mesleki Bilgiler ve Uygulama Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Becerileri D.3.1 Panel dizilerinin gerilim seviyelerini \u00f6l\u00e7er. D.3.2 D.3.3 Konekt\u00f6r ba\u011flant\u0131lar\u0131n\u0131n a\u00e7\u0131k devre u\u00e7lar\u0131nda D.3.4 kopukluk olup olmad\u0131\u011f\u0131n\u0131 \u00f6l\u00e7erek kontrol eder. \u00d6l\u00e7\u00fcm sonucuna g\u00f6re uygunsuzluk durumunda uygunsuzlu\u011fun d\u00fczeltilmesini sa\u011flar. G\u00fcne\u015f panellerinden olu\u015fturulan dizilerin kablolar\u0131n\u0131 etiketlemeye uygun olarak ba\u011flanmas\u0131n\u0131 sa\u011flar. 5.4. Yeterlilik Kontrol Listesi-4 (Evirici ve di\u011fer elektriksel bile\u015fenlerin montaj\u0131n\u0131n yap\u0131lmas\u0131n\u0131 sa\u011flamak) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.4.1 Kablo tavalar\u0131n\u0131n veya kanallar\u0131n\u0131n kapaklar\u0131n\u0131n 30. S\u00f6zl\u00fc ve yaz\u0131l\u0131 ileti\u015fim D.4.2 kapat\u0131lmas\u0131n\u0131 sa\u011flar. 31. Talimat takibi D.4.3 32. Temel in\u015faat teknikleri D.4.4 Talimata g\u00f6re panel ve eviricilerin topraklama 33. Temel mekanik hatlar\u0131n\u0131n \u00e7ekilmesini sa\u011flar. 34. Topraklama direnci \u00f6l\u00e7me 35. Topraklama yapma Talimata uygun olarak y\u0131ld\u0131r\u0131m koruma 36. Y\u00fcksekte \u00e7al\u0131\u015fma elemanlar\u0131n\u0131n montaj\u0131n\u0131n yap\u0131lmas\u0131n\u0131 sa\u011flar. Eviricilerin talimata uygun olarak monte edilmesini sa\u011flar. D.4.5 Evirici ile fotovoltaik dizi aras\u0131ndaki kablo ba\u011flant\u0131s\u0131n\u0131n etiketlemeye uygun olarak yap\u0131lmas\u0131n\u0131 sa\u011flar. D.4.6 Denetleyici ve kesici montaj\u0131n\u0131n talimata uygun olarak yap\u0131lmas\u0131n\u0131 sa\u011flar. D.4.7 A\u015f\u0131r\u0131 ak\u0131m ve a\u015f\u0131r\u0131 gerilim koruma cihazlar\u0131n\u0131n D.4.8 montaj\u0131n\u0131n talimata uygun olarak yap\u0131lmas\u0131n\u0131 sa\u011flar. Enerji depolamal\u0131 sistemlerde, enerji depolama ekipman\u0131n\u0131n, \u015farj kontrol cihaz\u0131n\u0131n ve di\u011fer ilgili ekipmanlar\u0131n talimata uygun olarak monte edilmesini sa\u011flar. D.4.9 Evirici ve pano aras\u0131 kablolar\u0131n etiketlemeye uygun olarak \u00e7ekilmesini sa\u011flar. D.4.10 Elektrik devre \u015femas\u0131na g\u00f6re evirici elektrik panolar\u0131n\u0131n montaj\u0131n\u0131n yap\u0131lmas\u0131n\u0131 sa\u011flar. D.4.11 Di\u011fer elektriksel ekipman\u0131n (ak\u00fc, \u015farj kontrol cihaz\u0131 ve benzeri) kablolar\u0131n\u0131n etiketlemeye uygun olarak \u00e7ekilmesini sa\u011flar. MOD\u00dcL 5 - 140","5.5. Yeterlilik Kontrol Listesi-5 (Topraklama direncini \u00f6l\u00e7mek) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.5.1 Topraklama devresinin fiziksel kontrol\u00fcn\u00fc (ek yerlerinin sa\u011flaml\u0131\u011f\u0131, k\u00f6\u015fe d\u00f6n\u00fc\u015flerinin kontrol\u00fc ve D.5.2 benzeri) yapar. D.5.3 Topraklama cihaz\u0131n\u0131 \u00f6l\u00e7\u00fcm talimat\u0131na g\u00f6re haz\u0131r hale D.5.4 getirir. D.5.5 Topraklama devresinin direncini topraklama \u00f6l\u00e7\u00fcm cihaz\u0131yla \u00f6l\u00e7er. \u00d6l\u00e7\u00fcm sonucunun belirtilen de\u011ferde veya de\u011ferin alt\u0131nda olup olmad\u0131\u011f\u0131n\u0131 kontrol eder. \u00d6l\u00e7\u00fcm ve kontrol sonucuna g\u00f6re uygunsuzluk durumunda uygunsuzlu\u011fun d\u00fczeltilmesini sa\u011flar. 5.6. Yeterlilik Kontrol Listesi-6 (Elektrik panolar\u0131n\u0131n ve eviricinin elektrik kablo ba\u011flant\u0131lar\u0131n\u0131 yapmak) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.6.1 Faz\/polarite ili\u015fkilerini ve toprak empedans\u0131n\u0131 kontrol eder. D.6.2 Eviriciye ba\u011flanacak kablolarda toprak ka\u00e7a\u011f\u0131 \u00f6l\u00e7\u00fcm\u00fcn\u00fc yapar. D.6.3 Kontrol ve \u00f6l\u00e7\u00fcm sonucuna g\u00f6re uygunsuzluk durumunda uygunsuzlu\u011fu d\u00fczeltir. Kablolar\u0131 projede belirtilen s\u0131rada ve kesitte D.6.4 evirici giri\u015flerine devre \u015femas\u0131na uygun olarak ba\u011flar. 5.7. Yeterlilik Kontrol Listesi-7 (Elektriksel bile\u015fenlerin montaj\u0131n\u0131 kontrol etmek) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.7.1 Yap\u0131lan elektriksel bile\u015fenlerin montaj\u0131n\u0131n, D.7.2 elektrik devre \u015femas\u0131na uygunlu\u011funu montaj s\u00fcrecinin her ad\u0131m\u0131nda kontrol eder. Kontrol sonucuna g\u00f6re uygunsuzlu\u011fun giderilmesini sa\u011flar. 5.8. Yeterlilik Kontrol Listesi-8 (Elektriksel bile\u015fenlerin kurulum sonras\u0131 s\u00fcre\u00e7leri y\u00fcr\u00fctmek) Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri D.8.1 Talimatta belirtilen uyar\u0131 levhalar\u0131n\u0131 monte edilmesini sa\u011flar. D.8.2 Kullan\u0131lan makine ve ekipmanlar\u0131n\u0131 i\u015f bitiminde toplanarak temizlenmesini sa\u011flar. D.8.3 \u00c7al\u0131\u015fma alan\u0131n\u0131n temizlenerek sonraki i\u015flemler D.8.4 i\u00e7in uygun hale getirilmesini sa\u011flar. Elektriksel bile\u015fenlerin montaj\u0131 sonras\u0131 s\u00fcre\u00e7lerin y\u00fcr\u00fct\u00fclmesini sa\u011flamak i\u00e7in ilgili birimlere bilgi verir. MOD\u00dcL 5 - 141","5.9. Yeterlilik Kontrol Listesi-9 (\u0130\u015f S\u00fcre\u00e7lerinde \u0130\u015f Sa\u011fl\u0131\u011f\u0131 ve G\u00fcvenli\u011fi Talimatlar\u0131n\u0131 Uygulamak) Ba\u015far\u0131m \u00f6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri A.1.1 \u0130SG ile ilgili \u00f6nlemleri g\u00f6z \u00f6n\u00fcnde bulundurarak 1. Acil durum t\u00fcrleri ve acil durum kendisini ve \u00e7evresindekileri riske atmayacak talimatlar\u0131na uygun davranma \u015fekilde \u00e7al\u0131\u015f\u0131r. 2. Ara\u00e7, gere\u00e7 ve ekipmanlar\u0131n A.1.2 \u0130\u015fyerindeki makine, ara\u00e7 ve gere\u00e7lerini ve ilgili g\u00fcvenli kullan\u0131m\u0131 ile ilgili talimat donan\u0131mlar\u0131n\u0131 sa\u011fl\u0131k ve g\u00fcvenlik i\u015faretlerini ve ve prosed\u00fcrler ve bunlar\u0131 i\u015f s\u00fcre\u00e7lerine uygulama talimatlar\u0131na g\u00f6re kullan\u0131r. A.1.3 \u00c7al\u0131\u015fma ortam\u0131nda i\u015f s\u00fcre\u00e7lerine g\u00f6re uygun ve 3. \u00c7al\u0131\u015fma ortam\u0131ndaki risk ve i\u015fveren taraf\u0131ndan sa\u011flanan KKD\u2019leri talimatlara tehlikeleri belirleme y\u00f6ntem ve teknikleri uygun kullanarak \u00e7al\u0131\u015f\u0131r. A.1.4 Kendisini ve \u00e7evresini etkileyece\u011fini g\u00f6zlemledi\u011fi 4. Elektrik ile \u00e7al\u0131\u015fma kurallar\u0131 ve tehlike, risk ve ramak kala olaylar\u0131 yaz\u0131l\u0131 ve\/veya al\u0131nacak \u00f6nlemler 5. Enerji verimlili\u011fi ve temel s\u00f6zl\u00fc olarak ilgililere raporlar. tasarruf uygulamalar\u0131 A.1.5 Acil durumlarda, acil durum plan\u0131nda yer alan 6. \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011finde \u00f6nlemleri uygular. i\u015fverenlerin ve \u00e7al\u0131\u015fanlar\u0131n hukuki A.1.6 y\u00fck\u00fcml\u00fcl\u00fckleri \u0130\u015fyerinde \u0130SG ile ilgili kar\u015f\u0131la\u015ft\u0131\u011f\u0131 acil durumlar\u0131 7. \u0130\u015f s\u00fcre\u00e7leri ile ilgili mevzuat ve A.1.7 ilgili ki\u015filere iletir. kalite prosed\u00fcrleri uygulamalar\u0131 A.1.8 8. \u0130\u015f s\u00fcre\u00e7lerinin iyile\u015ftirilmesinde A.1.9 Y\u00fcksekte g\u00fcvenli \u00e7al\u0131\u015fma kurallar\u0131n\u0131 uygular. g\u00f6rev ve sorumluluklar\u0131 Elektrikle g\u00fcvenli \u00e7al\u0131\u015fma kurallar\u0131n\u0131 uygular. 9. \u0130\u015fyeri \u00e7al\u0131\u015fma temel prosed\u00fcrleri A.1.10 Risk de\u011ferlendirme \u00e7al\u0131\u015fmalar\u0131nda g\u00f6zlem ve g\u00f6r\u00fc\u015flerini ilgililere iletir. Sorumlulu\u011fundaki ki\u015filerin \u0130SG kurallar\u0131na uyma durumlar\u0131n\u0131 kontrol eder 5.10. Yeterlilik Kontrol Listesi-10 (\u0130\u015f s\u00fcre\u00e7lerinde \u00e7evre koruma \u00f6nlemlerini uygulamak) Ba\u015far\u0131m \u00f6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri A.2.1 \u0130\u015f s\u00fcre\u00e7lerindeki olas\u0131 \u00e7evre tehlike ve risklerine 1. Kalite ve s\u00fcre\u00e7 iyile\u015ftirme uygun \u00e7al\u0131\u015f\u0131r. 2. Ki\u015fisel koruyucu donan\u0131m A.2.2 \u0130\u015f s\u00fcre\u00e7lerinde ortaya \u00e7\u0131kan at\u0131klar\u0131n tasnifini t\u00fcrleri, kullan\u0131m ve bak\u0131m talimatlara g\u00f6re yapar. \u00f6zellikleri 3. Sa\u011fl\u0131k ve g\u00fcvenlik i\u015faretlerini tan\u0131ma ve takip \u00c7al\u0131\u015ft\u0131\u011f\u0131 ortamdaki geri kazan\u0131labilir materyallerin etme A.2.3 toplanmas\u0131na ve muhafazas\u0131na ili\u015fkin belirlenen 4. Temel at\u0131k y\u00f6netimi ve \u00e7evre \u00f6nlemleri uygular. koruma \u00f6nlemleri 5. Y\u00fcksekte \u00e7al\u0131\u015fma kurallar\u0131 ve al\u0131nacak \u00f6nlemler 5.11. Yeterlilik Kontrol Listesi-11 (\u0130\u015f s\u00fcre\u00e7lerinde Kalite gerekliliklerini uygulamak) Ba\u015far\u0131m \u00f6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri A.3.1 Ger\u00e7ekle\u015ftirdi\u011fi i\u015flerde belirlenmi\u015f kalite 1. Kalite ve s\u00fcre\u00e7 iyile\u015ftirme gerekliliklerine uygun olarak \u00e7al\u0131\u015f\u0131r. 2. Ki\u015fisel koruyucu donan\u0131m A.3.2 \u0130\u015f s\u00fcre\u00e7lerinin iyile\u015ftirilmesine y\u00f6nelik g\u00f6r\u00fc\u015f ve t\u00fcrleri, kullan\u0131m ve bak\u0131m \u00f6nerilerini ilgililere iletir. \u00f6zellikleri A.3.3 Kontrol sonu\u00e7lar\u0131na g\u00f6re belirledi\u011fi ve yetkisi 3. Sa\u011fl\u0131k ve g\u00fcvenlik i\u015faretlerini d\u00e2hilinde olan uygunsuzluklar\u0131 giderir. tan\u0131ma ve takip etme A.3.4 Kontrol sonu\u00e7lar\u0131na g\u00f6re yetkisi d\u00e2hilinde olmayan 4. Temel at\u0131k y\u00f6netimi ve \u00e7evre koruma \u00f6nlemleri ve gideremedi\u011fi uygunsuzluklar\u0131 amirine\/ilgililere iletir. 5. Y\u00fcksekte \u00e7al\u0131\u015fma kurallar\u0131 ve al\u0131nacak \u00f6nlemler MOD\u00dcL 5 - 142","FAYDALANILAN KAYNAKLAR https:\/\/www.solarinsure.com\/protect-your-solar-power-system-from-lightning Serdar Aksoy, G\u00fcne\u015f Santrallerinde IEC 62305 Standard\u0131 Kapsam\u0131nda Y\u0131ld\u0131r\u0131mdan Korunma, Topraklama ve AG Parafudr Se\u00e7imi (https:\/\/www.emo.org.tr\/ekler\/dabe4e08ebc2829_ek.pdf) https:\/\/www.hes.com.tr\/assets\/doc\/Enerji_Katalog.pdf https:\/\/www.solarian.com.tr\/gunes-enerjisi-santralleri-ges-denetimi-ve-olcum-hizmetleri\/ https:\/\/search.abb.com\/library\/Download.aspx?DocumentID=1SDC210100D0206&LanguageCode=en &DocumentPartId=&Action=Launch https:\/\/www.tedas.gov.tr\/sx.web.docs\/tedas\/img\/30kWpTipSartname_29112014_v2.pdf https:\/\/www.enerjibes.com\/tek-hat-semasi\/ https:\/\/elektrikinfo.com\/tek-hat-semasi-nedir\/ https:\/\/www.ersekablo.com.tr\/Assets\/Documents\/Kablosan-Turkey_Kablo-Tanimi-ve-Yapisal- ozellikleri.pdf https:\/\/tr.prysmiangroup.com\/sites\/default\/files\/atoms\/files\/enerji-kablolari-rumuzlandirma.pdf MEGEP, Elektrik Elektronik Teknolojileri Alan\u0131, \u201cA\u00e7\u0131k Alanlarda G\u00fcne\u015f Panel Sisteminin Kurulmas\u0131 Mod\u00fcl\u00fc\u201d, Ankara, 2012. MEGEP, Elektrik Elektronik Teknolojileri Alan\u0131, \u201cSistem Topraklamalar\u0131 Mod\u00fcl\u00fc\u201d, Ankara, 2012. \u015eebekeye Ba\u011fl\u0131 Fotovoltaik G\u00fcne\u015f Sistemleri \u0130\u00e7in Uygulama Rehberi, K\u0131br\u0131s TMMOB EMO, 2021 Maxima Enerji Sistemleri, G\u00fcne\u015f Enerji Santrallerinde Kablo \u0130zolasyon Koruma Uygulamalar\u0131, 2022 Maxima Enerji Sistemleri, G\u00fcne\u015f Enerji Santrallerinde Kablo \u0130zolasyon Uygulamalar\u0131, 2022 TEDA\u015e-MLZ-2015-061 Fotovoltaik Sistemler \u0130\u00e7in DC Elektrik Kablolar\u0131 Teknik \u015eartnamesi MEGEP, Elektrik Elektronik Teknolojileri Alan\u0131, \u201cHibrit (G\u00fcne\u015f - R\u00fczg\u00e2r) Sistemi Kurulumu Mod\u00fcl\u00fc\u201d, Ankara, 2019 MEGEP, Elektrik Elektronik Teknolojileri Alan\u0131, \u201c\u00c7evirici Sisteminin Kurulumu Mod\u00fcl\u00fc\u201d, Ankara, 2012 MEGEP, Elektrik Elektronik Teknolojileri Alan\u0131, \u201cG\u00fcne\u015f Panellerini \u0130\u015fletmeye Alma Mod\u00fcl\u00fc\u201d, Ankara, 2015 MOD\u00dcL 5 - 143","Mod\u00fcl 5 Bu Sayfada Sonlanm\u0131\u015ft\u0131r. MOD\u00dcL 5 - 144","MOD\u00dcL 6 FOTOVOLTA\u0130K G\u00dc\u00c7 S\u0130STEMLER\u0130N\u0130N BAKIM VE ONARIMI","MOD\u00dcL K\u00dcNYES\u0130 Mod\u00fcl Ba\u015fl\u0131\u011f\u0131: Fotovoltaik G\u00fc\u00e7 Sistemlerinin Bak\u0131m ve Onar\u0131m\u0131 Mod\u00fcl\u00fcn Amac\u0131: Fotovoltaik g\u00fc\u00e7 sistemlerinin bak\u0131m ve onar\u0131m s\u00fcre\u00e7lerini y\u00fcr\u00fct\u00fcr, s\u00fcre\u00e7 y\u00f6netiminde i\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile kalite ve \u00e7evre y\u00f6netim gerekliliklerini uygular. \u00d6\u011frenme Kazan\u0131mlar\u0131: \u00d6\u011frenme Kazan\u0131m\u0131 1: Fotovoltaik g\u00fc\u00e7 sisteminin bak\u0131m onar\u0131m\u0131n\u0131 yapar. Alt \u00d6\u011frenme Kazan\u0131mlar\u0131: 1.1: Bak\u0131m onar\u0131m i\u00e7in haz\u0131rl\u0131k yapar. 1.2: Bak\u0131m onar\u0131m yapar. \u00d6\u011frenme Kazan\u0131m\u0131 2: \u0130SG, \u00e7evre ve kalite gerekliliklerini uygular. Alt \u00d6\u011frenme Kazan\u0131mlar\u0131: 2.1: \u0130\u015f s\u00fcre\u00e7lerinde \u0130SG kurallar\u0131n\u0131 uygular. 2.2: \u0130\u015f s\u00fcre\u00e7lerinde \u00e7evre koruma gerekliliklerini uygular. 2.3: \u0130\u015f s\u00fcre\u00e7lerinde kalite gerekliliklerini uygular. \u00d6nerilen Teorik E\u011fitim S\u00fcresi (Saat): T: 22, M:22 \u00d6nerilen Uygulamal\u0131 E\u011fitim S\u00fcresi: T: 22, M:22 MOD\u00dcL 6 - 2","Konu MOD\u00dcL \u0130\u00c7ER\u0130K TABLOSU Sayfa No Kodu 4 Konu 1 Konu Ba\u015fl\u0131klar\u0131 23 Konu 2 2.1. Fotovoltaik G\u00fc\u00e7 Sistemleri Bak\u0131m ve Onar\u0131m Esaslar\u0131na Giri\u015f 24 Fotovoltaik G\u00fc\u00e7 Sistemleri Ta\u015f\u0131y\u0131c\u0131 Ekipman Bak\u0131m ve Onar\u0131m\u0131 2.2. Ta\u015f\u0131y\u0131c\u0131 Sistemlerde Ar\u0131za \u00c7e\u015fitleri 42 Konu 3 3.1. Ta\u015f\u0131y\u0131c\u0131 Sistemlerde Bak\u0131m ve Onar\u0131m 54 3.2. Fotovoltaik Panellerin Bak\u0131m ve Onar\u0131m\u0131 G\u00fcne\u015f Panellerinde Ar\u0131za \u00c7e\u015fitleri 60 3.3. Fotovoltaik Panellerinde Bak\u0131m ve Onar\u0131m Konu 4 79 4.1. G\u00fcne\u015f Panellerinde Temizleme Y\u00f6ntemleri 4.2. Eviricilerin Bak\u0131m ve Onar\u0131m\u0131 87 Konu 5 Eviricilerde Ar\u0131za \u00c7e\u015fitleri 5.1. Eviricilerde Bakim ve Onar\u0131m 96 5.2. Fotovoltaik Sistemlerde Di\u011fer Bile\u015fenlerin Bak\u0131m Ve Onar\u0131m\u0131 5.3. Fotovoltaik Sistemlerde Di\u011fer Bile\u015fenler ve \u00d6zellikleri 101 Konu 6 Fotovoltaik Sistemlerde Di\u011fer Bile\u015fenlerde Ar\u0131za \u00c7e\u015fitleri Fotovoltaik Sistemlerde Di\u011fer Bile\u015fenlerin Bak\u0131m ve Onar\u0131m\u0131 110 6.1. Fotovoltaik G\u00fc\u00e7 Sistemleri Elektriksel Ba\u011flant\u0131lar Bak\u0131m ve 6.2. Onar\u0131m\u0131 113 Konu 7 Temel Elektrik Ba\u011flant\u0131lar\u0131nda Ar\u0131za \u00c7e\u015fitleri 119 8.1. Temel Elektrik Ba\u011flant\u0131lar\u0131nda Bakim ve Onar\u0131m 125 8.2. Koruma ve \u00d6l\u00e7\u00fc Elemanlar\u0131n\u0131n Bak\u0131m ve Onar\u0131m\u0131 127 8.3. Koruma ve \u00d6l\u00e7\u00fc Elemanlar\u0131 ve \u00d6zellikleri 128 Konu 8 Koruma ve \u00d6l\u00e7\u00fc Elemanlar\u0131nda Ar\u0131za \u00c7e\u015fitleri 8.1. Koruma ve \u00d6l\u00e7\u00fc Elemanlar\u0131nda Bak\u0131m ve Onar\u0131m 8.2. Haberle\u015fme Sistemlerinin Bak\u0131m ve Onar\u0131m\u0131 Konu 9 Haberle\u015fme Sistemleri ve \u00d6zellikleri 9.1. Haberle\u015fme Sistemlerinde Ar\u0131za \u00c7e\u015fitleri ve Bak\u0131m-Onar\u0131m 9.2. Enerji Depolamal\u0131 Sistemlerin Bak\u0131m ve Onar\u0131m\u0131 Konu 10 Enerji Depolamal\u0131 Sistemlerde Ar\u0131za \u00c7e\u015fitleri 10.1. Enerji Depolamal\u0131 Sistemlerde Bak\u0131m ve Onar\u0131m 10.2. Topraklama Elemanlar\u0131n\u0131n Bak\u0131m ve Onar\u0131m\u0131 Konu 11 Topraklama Sistemlerinde Olu\u015fan Ar\u0131zalar 11.1. Topraklama Sistemlerinin Bak\u0131m Onar\u0131m\u0131 11.2. Fotovoltaik G\u00fc\u00e7 Sistemleri Devreye Alma Konu 12 \u00c7al\u0131\u015fma Kontrol\u00fc Konu 13 M\u00fc\u015fteri \u0130li\u015fkileri ve \u0130leti\u015fim Konu 14 Uygulama Faaliyetleri \u00d6l\u00e7me ve De\u011ferlendirme Sorular\u0131 Yeterlilik Kontrol Listesi Faydalan\u0131lan Kaynaklar Mod\u00fcl Sonu MOD\u00dcL 6 - 3","KONU 1 BAKIM VE ONARIM ESASLARINA G\u0130R\u0130\u015e Fotovoltaik G\u00fc\u00e7 Santrallerinde bak\u0131m onar\u0131m uygulamalar\u0131 yaparken, bak\u0131m yap\u0131lacak alanda mutlaka elektriksel ve \u00e7evresel \u00f6nlemlerin al\u0131nmas\u0131 gerekmekte, ilgili bak\u0131m onar\u0131m talimatlar\u0131na uyulmas\u0131 istenmektedir. \u00c7evresel ve Elektriksel ko\u015fullar\u0131n g\u00f6zetimi ve \u00f6nlemlerin al\u0131nmas\u0131 ile kalite g\u00fcvencesine y\u00f6nelik baz\u0131 hususlar a\u015fa\u011f\u0131da listelenmi\u015ftir. 1.1. \u00c7EVRESEL \u00d6NLEMLER \u2022 Bak\u0131m-onar\u0131m yap\u0131lacak alan\u0131n \u00f6zelliklerine g\u00f6re ISG talimatlar\u0131n\u0131n yerine getirilmesi. \u2022 \u00d6rne\u011fin \u00e7at\u0131da bak\u0131m-onar\u0131m i\u015flerinin ger\u00e7ekle\u015ftirilmesi isteniyorsa, y\u00fcksekte \u00e7al\u0131\u015fma talimatlar\u0131n\u0131n yerine getirilmesi ve g\u00f6zetilmesi gerekmektedir. \u2022 Merdiven kullan\u0131m\u0131n\u0131n gerektirdi\u011fi i\u015flerde, merdiven kullan\u0131m talimat\u0131 ile y\u00fcksekte \u00e7al\u0131\u015fma talimatlar\u0131n\u0131n yerine getirilmesi veya g\u00f6zetilmesi gerekmektedir. \u2022 Bak\u0131m-Onar\u0131m i\u015flerinin ba\u015flan\u0131lmadan \u00f6nce ilgili alana g\u00fcvenlik bariyerlerinin veya levha ve i\u015faret\u00e7ilerinin yerle\u015ftirilmesi gerekmektedir. \u201cBu alanda bak\u0131m-onar\u0131m \u00e7al\u0131\u015fmas\u0131 vard\u0131r\u201d i\u015fini niteleyen uygun levha ve i\u015faret\u00e7ilerin kullan\u0131lmas\u0131 gerekmektedir. \u2022 Bak\u0131m-Onar\u0131m i\u015fleri \u00f6ncesinde uygun ki\u015fisel koruyucu donan\u0131mlar\u0131n ku\u015fan\u0131lmas\u0131 gerekmektedir. \u2022 \u00c7al\u0131\u015fma yap\u0131lacak alanda uygun olmayan yap\u0131 ve ortam ko\u015fullar\u0131 var ise, mutlaka ilgili durum nezdinde risk analizi de\u011ferlendirilerek gerekli \u00f6nlemler al\u0131nmal\u0131 veya ilgili bozucu etki ortadan kald\u0131r\u0131larak \/ ortadan kald\u0131r\u0131lmas\u0131 beklenilerek \u00e7al\u0131\u015fmaya ba\u015flan\u0131lmas\u0131 gerekmektedir. 1.2. ELEKTR\u0130KSEL \u00d6NLEMLER \u2022 \u00c7al\u0131\u015fma yap\u0131lacak alanda tehlikeli gerilim veya potansiyel gerilim durumlar\u0131na kar\u015f\u0131n \u00f6ncelikle ilgili alandaki sistemin elektrik devresinin a\u00e7\u0131k devre pozisyonuna getirilmesi istenmelidir. \u2022 Elektri\u011fin ilgili b\u00f6l\u00fcmden ar\u0131nd\u0131r\u0131lmas\u0131- enerjinin kesilmesinin ard\u0131ndan, potansiyel elektrik ile ilgili risklerin olmas\u0131 halleri g\u00f6z \u00f6n\u00fcnde bulundurularak, i\u015fe hemen ba\u015flan\u0131lmamal\u0131 ve belirli bir s\u00fcre beklenilerek ilgili cihaz ve ekipmanlar\u0131n \u00fczerindeki potansiyel enerjilerinin de\u015farj olmas\u0131 beklenilmelidir. \u2022 Fotovoltaik sistemlerde \u00f6zellikle panel ve evirici k\u0131s\u0131mlar\u0131nda yap\u0131lacak \u00e7al\u0131\u015fmalarda potansiyel elektrik risklerine kar\u015f\u0131n, izole eldiven ve izole ayakkab\u0131 gibi \u00f6nemli ki\u015fisel koruyucu donan\u0131mlar\u0131n kullan\u0131lmas\u0131na \u00f6zen g\u00f6sterilmelidir. \u2022 Elektrik devresi kesilen ilgili alanda, yetkili personellerce LOTOTO (EKED) uygulamas\u0131n\u0131n yap\u0131lmas\u0131 istenmeli ve g\u00f6zetilmelidir (\u015eekil 1). \u2022 EKED, bir makine ya da ekipman \u00fczerinde bir \u00e7al\u0131\u015fma ger\u00e7ekle\u015fmeye ba\u015flamadan \u00f6nce, tehlikeli enerjiyi kontrol alt\u0131na almakta ve s\u0131f\u0131r enerji durumuna getirmekte kullan\u0131lan birincil ve tercih edilen bir y\u00f6ntemdir. Makine veya ekipman ile enerji kayna\u011f\u0131 aras\u0131ndaki ba\u011flant\u0131 do\u011fru \u015fekilde kesildikten ya da izole edildikten sonra, makine ya da ekipman etiketlenmeli, kilitlenmeli, emniyete al\u0131nmal\u0131 ve denenmelidir. \u015eekil 1. \u00d6rnek EKED uygulamas\u0131 MOD\u00dcL 6 - 4","1.3. KAL\u0130TE G\u00dcVENCES\u0130 TEST VE STANDARTLARI IEC 62446-1: Test, dok\u00fcmantasyon ve bak\u0131m gereksinimleri- B\u00f6l\u00fcm 2: \u015eebekeye ba\u011fl\u0131 sistemler- Dok\u00fcmantasyon, devreye alma testleri ve muayene IEC 62446-2: Test, dok\u00fcmantasyon ve bak\u0131m gereksinimleri- B\u00f6l\u00fcm 2: \u015eebeke ba\u011flant\u0131l\u0131 sistemler- FV sistemlerinin bak\u0131m\u0131 IEC 62446-3: Test, dok\u00fcmantasyon ve bak\u0131m gereksinimleri- B\u00f6l\u00fcm 3: Fotovoltaik mod\u00fcller ve santraller- D\u0131\u015f Ortam infrared termografi IEC 61829: Fotovoltaik (FV) dizisi- Ak\u0131m-voltaj \u00f6zelliklerinin yerinde \u00f6l\u00e7\u00fcm\u00fc IEC 60891: Fotovoltaik mod\u00fcller- \u00d6l\u00e7\u00fclen I-V \u00f6zelliklerine s\u0131cakl\u0131k ve \u0131\u015f\u0131n\u0131m d\u00fczeltmeleri i\u00e7in prosed\u00fcrler IEC 61724-1: Fotovoltaik sistem performans\u0131- B\u00f6l\u00fcm 1: \u0130zleme IEC 61724-2: Fotovoltaik sistem performans\u0131- B\u00f6l\u00fcm 2: Kapasite de\u011ferlendirme y\u00f6ntemi IEC 61724-3: Fotovoltaik sistem performans\u0131- B\u00f6l\u00fcm 3: Enerji de\u011ferlendirme y\u00f6ntemi IEC 61557-1: 1000 V AC ve 1500 V DC'ye kadar al\u00e7ak gerilim da\u011f\u0131t\u0131m sistemlerinde elektrik g\u00fcvenli\u011fi B\u00f6l\u00fcm 1: Genel gereklilikler B\u00f6l\u00fcm 2: \u0130zolasyon Direnci B\u00f6l\u00fcm 3: \u00c7evrim Empedans\u0131 B\u00f6l\u00fcm 4: Toprak Ba\u011flant\u0131 Direnci ve E\u015f potansiyel Ba\u011flant\u0131 B\u00f6l\u00fcm 5: Toprak Kar\u015f\u0131 Diren\u00e7 IEC 61215: Fotovoltaik mod\u00fcllerin teknik spesifikasyonlar\u0131na ili\u015fkin kurallar TSE 495: Yap\u0131 elemanlar\u0131n\u0131n boyutland\u0131r\u0131lmas\u0131nda al\u0131nacak y\u00fcklerin hesap de\u011ferlerine ili\u015fkin kurallar TS EN 61194: \u015eebekeden ba\u011f\u0131ms\u0131z fotovoltaik sistemlerin karakteristik parametreleri 1.4. BAKIM VE ONARIM S\u00dcRE\u00c7LERINDE KULLANILAN MALZEME VE EKIPMANLAR Fotovoltaik G\u00fc\u00e7 Sistemlerinin Bak\u0131m ve Onar\u0131m s\u00fcre\u00e7lerinde kullan\u0131lan mekanik ve elektriksel malzeme ve ekipman \u00e7e\u015fitlerinden baz\u0131lar\u0131 Tablo 1\u2019de g\u00f6sterilmi\u015ftir. Her malzeme ve ekipman\u0131n kullan\u0131m y\u00f6nergelerinin incelenmesi ve ilgili i\u015fe ait malzeme ve ekipman\u0131n do\u011fru bir \u015fekilde kullan\u0131lmas\u0131 gerekmektedir. MOD\u00dcL 6 - 5","Tablo 1. Mekaniksel ve Elektriksel Malzeme ve Ekipman \u00c7e\u015fitleri \u0130zoleli \u00c7atal Bir A\u011f\u0131z D\u00f6rt k\u00f6\u015fe somun ve c\u0131vatalar\u0131n Anahtar s\u0131k\u0131l\u0131p s\u00f6k\u00fclmesinde kullan\u0131l\u0131r. \u0130zoleli Bir A\u011f\u0131z Y\u0131ld\u0131z anahtarlar, somun ya da Y\u0131ld\u0131z Anahtar c\u0131vata ba\u015flar\u0131n\u0131 her taraftan ku\u015fat\u0131r. Anahtar a\u011f\u0131zlar\u0131nda 6 noktadan ve 12 noktadan kavrayan tipleri mevcuttur. Kare ve alt\u0131gen c\u0131vata ba\u015flar\u0131n\u0131 d\u00f6nd\u00fcrmek i\u00e7in kullan\u0131labilir. \u0130zoleli \u00dcniversal Papa\u011fan pense ya da ba\u015fka bilinen Fort Pense ad\u0131yla fort pense, s\u0131k\u0131lacak malzemenin kal\u0131nl\u0131\u011f\u0131na ve geni\u015fli\u011fine g\u00f6re \u00e7ene a\u00e7\u0131kl\u0131\u011f\u0131 ayarlan\u0131r el g\u00fcc\u00fcyle ideal s\u0131kma sa\u011flan\u0131r bir el aletidir. \u0130zoleli Kombine Nesneleri b\u00fckmek, kavramak, Pense tutmak ve d\u00f6nd\u00fcrmek i\u00e7in kullan\u0131lan el aletleridir \u0130zoleli Kargaburnu Pense ile yap\u0131lan benzer i\u015flerde penseye nazaran daha hassas tutma ve s\u0131kma i\u015fleri yapmaya yarar. MOD\u00dcL 6 - 6","\u0130zoleli Yan Keski Kablo tel ve benzeri malzemeleri kesici \u00f6zelli\u011finden yararlan\u0131lan alettir. S\u00fcng\u00fcs\u00fc \u0130zoleli C\u0131vatalar\u0131 ve somunlar\u0131 seri \u015fekilde Lokma U\u00e7lu s\u00f6kmek ya da takmak i\u00e7in Tornavida kullan\u0131lan bir el aletidir \u0130zoleli Tek A\u011f\u0131zl\u0131 Uygun kesitte kablolar\u0131 kesmek i\u00e7in Kablo Kesici kullan\u0131lan el aletidir. \u0130zoleli D\u00fcz U\u00e7lu Vida s\u0131kma ve gev\u015fetme i\u015flerinde Tornavida kullan\u0131lan, vida \u015fekline g\u00f6re u\u00e7 k\u0131sm\u0131 de\u011fi\u015fen alettir. MOD\u00dcL 6 - 7","\u0130zoleli Y\u0131ld\u0131z U\u00e7lu Vida s\u0131kma ve gev\u015fetme i\u015flerinde Tornavida kullan\u0131lan, vida \u015fekline g\u00f6re u\u00e7 k\u0131sm\u0131 de\u011fi\u015fen alettir. Su terazisi Y\u00fczeylerin e\u011fim durumunu belirten veya g\u00f6steren hassas \u00f6l\u00e7\u00fc aletidir. Dijital g\u00f6stergeye sahip su terazileri ile e\u011fimin miktar\u0131 \u00f6l\u00e7\u00fclebilir ve g\u00f6r\u00fcnt\u00fclenebilir. Kumpas \u00c7ap, kal\u0131nl\u0131k, uzunluk, derinlik gibi \u00f6l\u00e7\u00fcmleri hassas bir \u015fekilde yapabilen aletlerdir. Kontrol Kalemi Sigorta gruplar\u0131nda, panolarda kablolar\u0131n ba\u011flant\u0131 noktalar\u0131nda \u00e7\u0131plak kablo y\u00fczeyinden, elektri\u011fin var olup olmad\u0131\u011f\u0131n\u0131 g\u00f6sterebilen aletlerdir. MOD\u00dcL 6 - 8","Alyan Anahtar Alt\u0131gen ba\u015fl\u0131\u011fa sahip alyan anahtarlar, \u00f6zel vida tiplerini d\u00f6nd\u00fcrmeye yarayan aletlerdir. Klemens tornavida Daha \u00e7ok kablolar\u0131n ba\u011fland\u0131\u011f\u0131 klemenslerde vidalar\u0131 d\u00f6nd\u00fcrmek i\u00e7in kullan\u0131lan bu tornavidalar ince ve uzun yap\u0131s\u0131yla k\u00fc\u00e7\u00fck boyutlu vidalarda i\u015flem yap\u0131lmas\u0131n\u0131 sa\u011flamaktad\u0131r. Kerpeten \u00c7ivi s\u00f6kmek, tel kesmek gibi i\u015flemleri yapmas\u0131n\u0131n yan\u0131nda elle tutulamayan ve kavranmayan malzemeleri iki ucu keskin metalden olu\u015fan yap\u0131s\u0131yla, s\u0131k\u0131 bir \u015fekilde tutmaya yarayan aletlerdir. \u0130ki a\u011f\u0131z \u00e7atal anahtar C\u0131vata ve somunlar\u0131 belirli a\u011f\u0131z tak\u0131m\u0131 a\u00e7\u0131klar\u0131na g\u00f6re se\u00e7ildi\u011fi zaman tam \u015fekilde kavrayan ve onlar\u0131 s\u0131kma ve gev\u015fetme i\u015flemlerinde kullan\u0131lan aletlerdir. MOD\u00dcL 6 - 9","Kombine Anahtar C\u0131vata ve somunlar\u0131 belirli a\u011f\u0131z Tak\u0131m\u0131 a\u00e7\u0131klar\u0131na g\u00f6re se\u00e7ildi\u011fi zaman tam \u015fekilde kavrayan ve onlar\u0131 s\u0131kma ve gev\u015fetme i\u015flemlerinde kullan\u0131lan aletlerdir. Y\u0131ld\u0131z Anahtar C\u0131vata ve somunlar\u0131 belirli a\u011f\u0131z Tak\u0131m\u0131 a\u00e7\u0131klar\u0131na g\u00f6re se\u00e7ildi\u011fi zaman tam \u015fekilde kavrayan ve onlar\u0131 s\u0131kma ve gev\u015fetme i\u015flemlerinde kullan\u0131lan aletlerdir. Kurba\u011fac\u0131k Ayarlanabilen a\u011f\u0131z a\u00e7\u0131kl\u0131\u011f\u0131 ile c\u0131vata ve somunlar\u0131 s\u0131kmaya veya gev\u015fetmeye yarayan aletlerdir. Tork Anahtar\u0131 Belirlenen s\u0131kma kuvvetini, c\u0131vatalara aktaran ve onlar\u0131 belli de\u011ferlerde s\u0131k\u0131lmas\u0131n\u0131 sa\u011flayan aletlerdir. MOD\u00dcL 6 - 10","Kaplama \u00d6l\u00e7\u00fcm Test Demir ve demir i\u00e7ermeyen Cihaz\u0131 durumlar\u0131 tan\u0131yabilen, kaplama (Galvaniz Kal\u0131nl\u0131k miktar\u0131n\u0131 \u00f6l\u00e7ebilen cihazlard\u0131r. \u00d6l\u00e7\u00fcmleri) Galvaniz kal\u0131nl\u0131k \u00f6l\u00e7\u00fcmlerinde kullan\u0131labilir. E\u011fe Metal malzemelerde, metal y\u00fczeyin yontulmas\u0131ndan kullan\u0131lan materyaldir. Tel F\u0131r\u00e7a Boya, pas ve tortular\u0131n metal y\u00fczeylerden ar\u0131nd\u0131r\u0131lmas\u0131nda ve kaz\u0131nmas\u0131nda kullan\u0131l\u0131r. Boya F\u0131r\u00e7as\u0131 Boya vb malzemelerin bir y\u00fczeye tutundurulmas\u0131nda kullan\u0131lan materyaldir. Multimetre Diren\u00e7, Ak\u0131m, Gerilim de\u011ferlerini \u00f6l\u00e7meye yarayan cihazlard\u0131r. MOD\u00dcL 6 - 11","\u0130zolasyon \u00d6l\u00e7\u00fc Aleti Kablo veya bile\u015fik sistemlerde izolasyon seviyesini topra\u011fa kar\u015f\u0131 diren\u00e7 miktar\u0131n\u0131 \u00f6l\u00e7meye yarayan elektriksel cihazlard\u0131r. Toprak Megeri Topra\u011f\u0131n yal\u0131tkanl\u0131k seviyesini \u00f6l\u00e7en elektriksel cihazlard\u0131r. Pensampermetre Genellikle alternatif ak\u0131m \u2013 do\u011fru Termal Kamera ak\u0131m sistemlerinde ak\u0131m \u00f6l\u00e7\u00fcm\u00fcn\u00fc, \u00f6l\u00e7\u00fc cihaz\u0131n\u0131 devreye seri ba\u011flama i\u015flemleri yapmadan toroid halka i\u00e7erisinden ak\u0131m ta\u015f\u0131nan kablonun ge\u00e7irilerek, ak\u0131m \u00f6l\u00e7\u00fcm\u00fc yap\u0131ld\u0131\u011f\u0131 cihazlard\u0131r. Farkl\u0131 tip ve modellerinde gerilim ve diren\u00e7 \u00f6l\u00e7\u00fcm se\u00e7enekleri de mevcuttur. G\u00f6zle g\u00f6r\u00fcnt\u00fclenemeyen \u0131s\u0131 enerjisini, seviyelerine g\u00f6re farkl\u0131 renk skalas\u0131nda g\u00f6sterebilen ve \u0131s\u0131 de\u011ferini g\u00f6r\u00fcnt\u00fclenmesine imkan veren cihazlard\u0131r. Solar \u00d6l\u00e7\u00fc Cihazlar\u0131 IV curve- Isc-Voc-Radyasyon \u2013 \u0130zolasyon direnci, polarite gibi \u00f6l\u00e7\u00fcmlerinin kombine bir \u015fekilde yap\u0131labildi\u011fi fotovoltaik karakteristik de\u011fer ve grafiklerinin g\u00f6r\u00fcnt\u00fclenebildi\u011fi cihazlard\u0131r. MOD\u00dcL 6 - 12","KONU 2 TA\u015eIYICI EK\u0130PMAN BAKIM VE ONARIMI FV g\u00fc\u00e7 sistemlerinde ta\u015f\u0131y\u0131c\u0131 ekipmanlar \u00fczerinde periyodik olarak yap\u0131lmas\u0131 gereken birtak\u0131m kontroller ve muayeneler bulunmaktad\u0131r. Bu kontrollerin baz\u0131lar\u0131 Tablo 2\u2019deki gibidir. Tablo 2. Ta\u015f\u0131y\u0131c\u0131 Sistemlerde Periyodik Kontroller 1 Ta\u015f\u0131y\u0131c\u0131 Sistemlerin Genel G\u00f6zle Kontrol\u00fc (Konstr\u00fcksiyon- Y\u0131lda 2 Kez Evirici Ask\u0131 Aparatlar\u0131-Kablo Tavalar\u0131 vb.) 2 Ta\u015f\u0131y\u0131c\u0131 Sistemlerin Pas-Korozyona Kar\u015f\u0131n G\u00f6zle Deformasyon Y\u0131lda 2 Kez Kontrolleri 3 Konstr\u00fcksiyon Sistemlerin B\u00fct\u00fcnsellik Kontrolleri (Yap\u0131sal Y\u0131lda 2 Kez Bozuklar\u0131n G\u00f6zle Kontrol ile Tespiti) 4 Ta\u015f\u0131y\u0131c\u0131 Sistemlerin Pas ve Korozyon Durumunda Onar\u0131c\u0131 Gerekti\u011finde M\u00fcdahalelerin yap\u0131lmas\u0131 5 Ba\u011flant\u0131 Aparatlar\u0131 ve Vidalar\u0131n B\u00fct\u00fcnsellik Kontrol\u00fc (G\u00f6zle Y\u0131lda 2 Kez Kontroller -Yap\u0131sal Bozukluk vb.) 6 Ba\u011flant\u0131 Elemanlar\u0131n\u0131n Tork Anahtar\u0131 ile S\u0131k\u0131l\u0131k-Gev\u015feklik Y\u0131lda 2 Kez Kontrol\u00fc 7 Galvaniz Kal\u0131nl\u0131k \u00d6l\u00e7\u00fcm\u00fc Gerekti\u011finde 2.1. TA\u015eIYICI S\u0130STEMLERDE ARIZA \u00c7E\u015e\u0130TLER\u0130 Fotovoltaik G\u00fc\u00e7 Sistemlerinde ta\u015f\u0131y\u0131c\u0131 yap\u0131larda ortaya \u00e7\u0131kan ar\u0131za durumlar\u0131n\u0131 a\u015fa\u011f\u0131daki \u015fekilde s\u0131ralayabiliriz. \u2022 Pas-Korozyon Durumlar\u0131 \u2022 Yap\u0131sal Bozukluklar \u2022 Montaj Hatalar\u0131 \u2022 \u0130\u015f\u00e7ilik Hatalar\u0131 \u2022 Ba\u011flant\u0131larda Gev\u015feklik Durumlar\u0131 \u2022 Ba\u011flant\u0131lar\u0131n Gere\u011finden Fazla S\u0131k\u0131lmas\u0131 \u2022 Yanl\u0131\u015f \u00dcr\u00fcn Kullan\u0131m\u0131 \u2022 Dizayn Hatalar\u0131 \u2022 Harici Olaylar Bu durumlar\u0131n baz\u0131lar\u0131na \u00f6rnek olu\u015fturan ar\u0131za durumlar\u0131 a\u015fa\u011f\u0131da \u015eekil 2-7\u2019de g\u00f6sterilmi\u015ftir. MOD\u00dcL 6 - 13","\u015eekil 2. Pas Korozyon Olu\u015fumlar\u0131 \u015eekil 3. Yap\u0131sal Bozukluklar \/ \u0130\u015f\u00e7ilik Hatalar\u0131 \u015eekil 3. Harici olaylar \/ \u0130\u015f\u00e7ilik Hatalar\u0131, Kayma, \u00c7\u00f6kme. Montaj Hatalar\u0131 MOD\u00dcL 6 - 14","\u015eekil 4. Yanl\u0131\u015f Dizayn \/ \u00dcr\u00fcn Kullan\u0131m\u0131 Kaynakl\u0131 Sorunlar \u015eekil 6. Ba\u011flant\u0131 Gev\u015fekliklerinden Kaynaklanan Sorunlar \u015eekil 7. Ba\u011flant\u0131 Tork Kontrolleri Kablo ta\u015f\u0131y\u0131c\u0131 hatlar\u0131nda (Tava Hatlar\u0131) genel olarak genel olarak kar\u015f\u0131m\u0131za \u00e7\u0131kan ve ar\u0131zaya sebep olan durumlar (\u015eekil 8): MOD\u00dcL 6 - 15","\u2022 Yanl\u0131\u015f \u00fcr\u00fcn se\u00e7imi \u2022 Dizayn Hatas\u0131 \u2022 \u0130\u015f\u00e7ilik Hatalar\u0131 \u2022 Harici Olaylar \u2022 Montaj Hatalar\u0131 \u015eekil 8. Kablo Tava Kapaklar\u0131n\u0131n Kapat\u0131lmamas\u0131 ve Kablo Hasar\/Deformasyon Sorunu Tava i\u00e7erisine serilen kablolar\u0131n tavan\u0131n keskin kenarlar\u0131na denk gelmesi ve izolasyon k\u0131l\u0131f\u0131n\u0131n zarar g\u00f6rmesi , y\u00fck alt\u0131nda iken ka\u00e7ak olu\u015fmas\u0131na ve yang\u0131na kadar hasar\u0131n b\u00fcy\u00fcmesine sebep olabilecektir (\u015eekil 9). \u015eekil 9. \u0130\u015f\u00e7ilik Hatas\u0131 \/ Solar Kablo Hasar ve Ar\u0131za Durumu MOD\u00dcL 6 - 16","2.2. TA\u015eIYICI S\u0130STEMLERDE BAKIM VE ONARIM 2.2.1. Tork Kontrol\u00fc ile S\u0131k\u0131l\u0131k Kontrol\u00fc Ba\u011flant\u0131 elemanlar\u0131n\u0131 s\u0131kma i\u015flemlerinde genel olarak y\u0131ld\u0131z, \u00e7atal, lokma ya da kombine anahtar gibi \u00e7e\u015fitli el aletleri kullan\u0131labilmektedir. Bu el aletleriyle yap\u0131lan i\u015flemler fiziksel veya i\u015flevsel olarak do\u011fru gibi g\u00f6z\u00fckse de vida c\u0131vata ba\u011flant\u0131s\u0131n\u0131n g\u00fcvenirli\u011fi a\u00e7\u0131s\u0131ndan hassas bir \u00e7al\u0131\u015fma \u015fekli de\u011fildir. Bir vida \u2013c\u0131vata grubunun \u00e7\u00f6z\u00fclmeye kar\u015f\u0131 en b\u00fcy\u00fck emniyeti teorik olarak hesaplanm\u0131\u015f olan tork de\u011feri ile s\u0131k\u0131lmas\u0131d\u0131r (Tablo 3). Bilindi\u011fi \u00fczere kuvvet bir cisme hareketini veren etkidir. Tork ise cismin bir kuvvet etkisinde d\u00f6nd\u00fcr\u00fclmesidir. Tablo 3. DIN-13 standard\u0131na g\u00f6re civata torklama tablosu: Metrik Somun Alyan 3.6 M 4.6 M 6.9 M 8.8 M 10.9 M 12.9 M \u00d6l\u00e7\u00fc \u00d6l\u00e7\u00fcs\u00fc \u00d6l\u00e7\u00fc [Nm] [Nm] M6 3,43 4,51 [Nm] [Nm] [Nm] [Nm] M7 10 8 5,59 7,45 M8 11+12 10 8,24 10,379 8,73 10,3 14,71 17,65 M10 13+14 12 16,67 21,57 M12 15+17 14 28,44 38,25 14,22 17,16 24,52 28,44 M14 19+21 14 45,11 60,8 M16 22+23 17 59,63 93,16 21,57 25,5 35,3 42,17 M18 24+26 17 95,13 127,49 M20 19 135,33 180,44 42,17 50,01 70,61 85,32 M22 27 19 182,4 245,17 M24 30 22 230,46 308,91 73,55 87,28 122,58 147,1 M27 32 24 343,23 460,92 M30 36 27 465,82 622,73 116,7 138,27 194,17 235,36 M33 41 27-30 632,53 848,28 M36 46 32 813,96 1088,54 178,48 210,84 299,1 357.94 M39 50 - 1059,12 1412,17 M42 55 36 1304,29 1745,59 245,17 289,3 411,88 490,34 M45 60 36 1637,72 2177,09 M48 65 41 1980,96 2638 348,14 411,88 578,5 696,28 M52 70 46 2539,94 3393,12 M56 75 46 3167,57 4226,69 470,72 558,98 784,54 941,44 M60 80 50 3932,49 5246,59 M64 85 55 4736,64 6305,71 598,21 710,99 1000,28 1196,42 M68 90 60 5788 7727 M72 95 65 6913 9228 887,51 1049,32 1480,81 1775,01 M76 100 70 8275 11047 M80 105 9625 12849 1206,23 1421,97 2010,38 2402,64 M90 110 14298 24941 M100 115 19613 26182 1627,91 1931,92 2716,46 3265,63 M110 130 26391 35230 M120 145 34588 46174 2098,64 2481,1 3491,19 4197,27 155 175 2716,46 3226,41 4530,7 5442,72 3363,7 3991,33 5609,44 6727,4 4207,08 4991,62 7011,8 8414,16 5080 6021,32 8473 10149,94 6541,08 7747,3 10885,45 13091,96 8149,38 9649,8 13582,29 16279,14 10100,91 11964,19 16867,54 20201,82 12160,32 14415,86 20299,89 24320,64 14891 17645 24809 29754 17785 21074 29631 35537 21290 25227 - - 24763 29341 - - 36271 42978 - - 50460 59790 - - 67898 80453 - - 88990 - - - MOD\u00dcL 6 - 17","M130 185 44300 59159 114015 - - - M140 200 M150 210 55706 77568 143321 - - - 68906 91986 177281 - - - a) S\u0131kma Torku Kuvvet etkisiyle d\u00f6nd\u00fcrme kolunun u\u00e7 k\u0131sm\u0131ndaki anahtar a\u011fz\u0131nda olu\u015fturulur ve birimi Nm\u2019dir. Bu s\u0131kma torku vida ba\u011flant\u0131s\u0131nda bir \u00f6n gerilme yarat\u0131r. S\u0131kma torkunun olmas\u0131 gerekenden d\u00fc\u015f\u00fck olmas\u0131, zamanla olu\u015fabilecek titre\u015fimler sebebiyle vida-c\u0131vata ba\u011flant\u0131s\u0131nda gev\u015feme, \u00e7\u00f6z\u00fclmeye yol a\u00e7abilir. \u00d6n gerilme kuvveti fazlaca olu\u015fan ba\u011flant\u0131larda ise par\u00e7alara zarar verebilir, ayn\u0131 zamanda vida \u00fczerindeki di\u015flerde meydana gelecek a\u015f\u0131nmalar ba\u011flant\u0131y\u0131 \u00e7\u00f6z\u00fclemez k\u0131labilir. b) Tork Anahtar\u0131n\u0131n Do\u011fru kullan\u0131m\u0131: Tork anahtar\u0131 ile \u00e7al\u0131\u015f\u0131rken dikkat edilmesi gereken baz\u0131 hususlar bulunmaktad\u0131r. \u2022 Hangi tip tork anahtar\u0131 olursa olsun d\u00f6nd\u00fcrme y\u00f6n\u00fcn\u00fcn aksine kuvvet uygulanmamal\u0131d\u0131r. \u2022 C\u0131rc\u0131r anahtarlar gibi tork anahtarlar\u0131n\u0131n da s\u00f6kme i\u015flemi i\u00e7in kullan\u0131lmamas\u0131 gerekir. \u2022 Klik sesli modellerde klik sesi duyuldu\u011fu anda ayarlanm\u0131\u015f tork de\u011ferine ula\u015f\u0131lm\u0131\u015f demektir, daha fazla kuvvet uygulanmamal\u0131d\u0131r. \u2022 G\u00f6vdesi hasar g\u00f6rm\u00fc\u015f, mekanizmas\u0131 bozulmu\u015f tork anahtarlar\u0131n\u0131n sap k\u0131sm\u0131ndan uygulanmal\u0131d\u0131r. \u2022 Kuvvet, tork anahtar\u0131n\u0131n sap k\u0131sm\u0131ndan uygulanmal\u0131d\u0131r. \u2022 Kullan\u0131mdan sonra nemden ve kirden korumak i\u00e7in her zaman kutusunda muhafaza edilmelidir. \u2022 Her kullan\u0131mdan sonra y\u00fck kolunda gereksiz gerginlik b\u0131rakmamak i\u00e7in tork anahtar\u0131ndaki y\u00fck\u00fc \u201c0 Nm\u201d \u2018ye getiriniz. \u2022 Tork anahtar\u0131n\u0131 s\u00f6kmeye, tamir etmeye \u00e7al\u0131\u015fmay\u0131n\u0131z. \u2022 Tork anahtar\u0131n\u0131 amac\u0131 d\u0131\u015f\u0131nda kullanmaya \u00e7al\u0131\u015fmay\u0131n\u0131z. Tork anahtar\u0131n\u0131n ayar i\u015flem ad\u0131mlar\u0131 \u015eekil 10 ve \u015eekil 11\u2019de g\u00f6sterilmektedir. \u015eekil 10. Tork anahtar\u0131n\u0131n ayar i\u015flem ad\u0131mlar\u0131-I MOD\u00dcL 6 - 18","\u015eekil 11. Tork anahtar\u0131n\u0131n ayar i\u015flem ad\u0131mlar\u0131-II 2.2.2. Galvanizleme, Onar\u0131m \u0130\u015flemleri Galvaniz, korozyona kar\u015f\u0131n metalin \u201c\u00e7inko\u201d ile kaplanmas\u0131d\u0131r. Galvaniz, metale (demir ya da \u00e7eliklere) uygulan\u0131r. Metal y\u00fczey \u00e7inko ile kaplanarak a\u015f\u0131nma direnci artt\u0131r\u0131l\u0131r. Fotovoltaik G\u00fc\u00e7 Sistemlerinde, ta\u015f\u0131y\u0131c\u0131 bile\u015fenlerin \u00e7o\u011funlu\u011fu \u00e7elik yap\u0131lardan olu\u015fmaktad\u0131r. Bu \u00e7elik yap\u0131lar fabrika a\u015famas\u0131nda galvanizleme yap\u0131larak \u00fcretilir. Kullan\u0131m yerine g\u00f6re galvaniz kal\u0131nl\u0131\u011f\u0131 de\u011fi\u015febilmektedir. Zamanla \u00e7evresel ko\u015fullar\u0131n etkisiyle galvaniz tabaka a\u015f\u0131narak, metalin oksijen ile tepkimesine sebebiyet verir. Metal y\u00fczeyin oksijen ile tepkimesi sonucu pas ve korozyon olu\u015fur ve hem dayan\u0131m y\u00f6n\u00fcnden hem de g\u00f6r\u00fcnt\u00fc itibariyle deformasyon a\u00e7\u0131\u011fa \u00e7\u0131kar. Fotovoltaik G\u00fc\u00e7 Sistemlerinde \u00f6zellikle konstr\u00fcksiyon yap\u0131lar\u0131nda periydik galvaniz kal\u0131nl\u0131\u011f\u0131 \u00f6l\u00e7\u00fcm\u00fc ile galvanizleme onar\u0131m prosed\u00fcrlerinin yap\u0131lmas\u0131 ihtiya\u00e7 haline gelmektedir. a) Galvaniz kal\u0131nl\u0131\u011f\u0131 \u00f6l\u00e7\u00fcm\u00fc: Piyasada bir\u00e7ok galvaniz kal\u0131nl\u0131k \u00f6l\u00e7\u00fcm\u00fc \u2013 kaplama kal\u0131nl\u0131k \u00f6l\u00e7\u00fcm\u00fc yapan cihaz bulunmaktad\u0131r. Kulland\u0131\u011f\u0131n\u0131z cihaz\u0131n kullan\u0131m k\u0131lavuzundaki \u00f6l\u00e7\u00fcm ad\u0131mlar\u0131n\u0131 takip ederek \u00f6l\u00e7\u00fcmleri ger\u00e7ekle\u015ftirebilirsiniz. Bunlardan biri \u00fczerinden \u00f6l\u00e7\u00fcm ad\u0131mlar\u0131 a\u015fa\u011f\u0131da anlat\u0131lm\u0131\u015ft\u0131r. Metal y\u00fczeylerdeki galvaniz kal\u0131nl\u0131k \u00f6l\u00e7\u00fcm\u00fc yapmadan \u00f6nce cihaz\u0131n kalibrasyon ayarlar\u0131n\u0131n kontrol edilmesi ve gerekliyse kalibrasyon ayarlar\u0131n\u0131n yap\u0131lmas\u0131 gerekmektedir. Zero-kalibrasyon: Bu ad\u0131mda, galvaniz kaplama olmayan bir y\u00fczey test \u00f6rne\u011fi (cihaz kutusunda bulunur) se\u00e7ilerek, cihaz ile \u00f6l\u00e7\u00fcm yap\u0131ld\u0131\u011f\u0131nda 0 de\u011feri g\u00f6zlemleniyorsa \u201czero kalibrasyon\u201d tamamlanm\u0131\u015ft\u0131r. E\u011fer farkl\u0131 bir de\u011fer g\u00f6z\u00fck\u00fcyorsa ayar tu\u015flar\u0131 ile 0 de\u011ferine getirilerek kaydedilir ve zero kalibrasyon tamamlan\u0131r (\u015eekil 12). MOD\u00dcL 6 - 19","\u015eekil 12. Zero-kalibrasyon i\u015flemi \u0130ki noktal\u0131 kalibrasyon: Bu kalibrasyon, kaplama kal\u0131nl\u0131k de\u011feri bilinen bir test \u00f6rne\u011fi (tester) ile kaplama kal\u0131nl\u0131k de\u011feri 0 olan bir test \u00f6rne\u011fi kullan\u0131larak yap\u0131lan kalibrasyon i\u015flemidir. Tester, genellikle cihaz\u0131n kutusu i\u00e7erisinde, cihaz ile beraber g\u00f6nderilmektedir. Kaplama de\u011feri \u00f6nceden bilinen test y\u00fczeyine, cihaz ile \u00f6l\u00e7\u00fcm yap\u0131ld\u0131\u011f\u0131nda kar\u015f\u0131m\u0131za \u00e7\u0131kan sonu\u00e7, test \u00f6rne\u011findeki de\u011ferden farkl\u0131 ise cihaz \u00fczerinden ayar tu\u015flar\u0131 ile ilgili sonu\u00e7 de\u011feri test kitinin de\u011ferine getirilir ve kaydedilir. Di\u011fer ad\u0131mda kaplama olmayan bir y\u00fczeye sahip test kitinin \u00f6l\u00e7\u00fcm\u00fcn \u201c0\u201d de\u011ferinin g\u00f6r\u00fclmesi gerekmektedir. Yine kar\u015f\u0131la\u015f\u0131lan sonu\u00e7 \u201c0\u201d de\u011ferinden farkl\u0131 ise ilgili de\u011fer cihaz \u00fczerindeki ayar tu\u015flar\u0131 ile, \u201c0\u201d de\u011ferine getirilir ve kaydedilir. B\u00f6ylelikle iki noktal\u0131 kalibrasyon i\u015flemi tamamlanm\u0131\u015f olur (\u015eekil 13). \u015eekil 13. \u0130ki noktal\u0131 kalibrasyon i\u015flemi b) Galvaniz kal\u0131nl\u0131\u011f\u0131 ne kadar olmal\u0131d\u0131r? \u00c7elik yap\u0131lar\u0131n\u0131n kal\u0131nl\u0131klar\u0131na g\u00f6re galvaniz kaplama kal\u0131nl\u0131\u011f\u0131 da de\u011fi\u015febilmektedir. Bununla ilgili ISO 1461 standard\u0131 referans al\u0131narak projelendirme ve tasar\u0131m a\u015famas\u0131nda ilgili hesaplamalar sonucu bu de\u011ferler \u00fcretici firmalara verilir veya \u00fcretici firmalar taraf\u0131ndan \u00f6nerilir. Genellikle 1.5-3.0 mm aras\u0131 kal\u0131nl\u0131ktaki malzemeler i\u00e7in galvaniz kal\u0131nl\u0131\u011f\u0131 ortalama 50-55 mikron seviyesinde olmal\u0131d\u0131r. ISO 1461:2009 \u2018a g\u00f6re kaplama kal\u0131nl\u0131k standartlar\u0131 Tablo 4\u2019te sunulmaktad\u0131r. MOD\u00dcL 6 - 20","Tablo 4. ISO 1461:2009 \u2018a g\u00f6re kaplama kal\u0131nl\u0131k de\u011ferleri c) Galvaniz Bak\u0131m Onar\u0131m Temizlik \u0130\u015flemleri Galvaniz bak\u0131m onar\u0131m ve temizlik i\u015flemlerinde kullan\u0131lan malzemelerin ba\u015fl\u0131calar\u0131 Tablo 5\u2019te verilmektedir. Tablo 5. Galvaniz bak\u0131m onar\u0131m ve temizlik i\u015flemlerinde kullan\u0131lan ba\u015fl\u0131ca malzemeler E\u011fe Tel F\u0131r\u00e7a Boya F\u0131r\u00e7as\u0131 \u00c7inko Sprey \u00c7inko Pasta Galvaniz Bak\u0131m Onar\u0131m Temizlik i\u015flem ad\u0131mlar\u0131 \u015eekil 14-17\u2019de g\u00f6sterilmektedir. 1. Ad\u0131m: E\u011fe yard\u0131m\u0131yla galvanizleme yap\u0131lacak y\u00fczeyde \u00e7apak vb. olu\u015fumlar temizlenir (\u015eekil 14) \u015eekil 13. E\u011fe yard\u0131m\u0131yla \u00e7apak vb. olu\u015fumlar\u0131n temizlenmesi MOD\u00dcL 6 - 21","2. Ad\u0131m: \u00c7apak temizli\u011fi sonras\u0131, profil a\u011f\u0131zlar\u0131nda soyulma g\u00f6r\u00fcld\u00fc\u011f\u00fc takdirde; ilgili b\u00f6lgeler tel f\u0131r\u00e7a yard\u0131m\u0131yla temizlenir ve \u00e7inko pasta ile bak\u0131m yap\u0131l\u0131r (\u015eekil 15). \u015eekil 14. Profil a\u011f\u0131zlar\u0131n\u0131n tel f\u0131r\u00e7a ile temizlenmesi 3. Ad\u0131m: Pas-korozyon olan y\u00fczeyler tel f\u0131r\u00e7a yard\u0131m\u0131yla temizlenmelidir (\u015eekil 16). \u015eekil 16. Pas\/korozyon olan b\u00f6lgelerin tel f\u0131r\u00e7a ile temizlenmesi 4. Ad\u0131m: \u00c7inko pasta s\u00fcr\u00fcm\u00fc ve pastadan kaynakl\u0131 mat g\u00f6r\u00fcn\u00fcm\u00fc kald\u0131rmak i\u00e7in, iste\u011fe g\u00f6re sprey de s\u0131k\u0131labilir. \u015eekil 17. \u00c7inko pasta s\u00fcr\u00fcm\u00fc MOD\u00dcL 6 - 22","\u00c7inko pasta kal\u0131n s\u00fcr\u00fclmemelidir (\u015eekil 18). \u015eekil 18. \u00c7inko pasta uygulamas\u0131 5. Ad\u0131m: Kaplanmam\u0131\u015f b\u00f6lgelerde TS EN 1461 Standard\u0131 referans al\u0131narak ilgili y\u00fczey korozyon, pas, \u00e7apak vb. olu\u015fumlardan temizlenip ard\u0131ndan \u00e7inko pasta s\u00fcr\u00fcld\u00fckten sonra, \u00e7inko sprey ile kaplama yap\u0131l\u0131r (\u015eekil 19). Bak\u0131m yap\u0131lan y\u00fczeyin kaplama kal\u0131nl\u0131\u011f\u0131 ilgili standarda g\u00f6re kontrol edilir. \u015eekil 19. \u00c7inko sprey uygulamas\u0131 MOD\u00dcL 6 - 23","KONU 3 FOTOVOLTA\u0130K PANELLER\u0130N BAKIM VE ONARIMI Fotovoltaik paneller \u00fczerinde periyodik olarak yap\u0131lmas\u0131 gereken birtak\u0131m kontroller ve muayeneler bulunmaktad\u0131r. Bu kontrollerin baz\u0131lar\u0131 Tablo 6\u2019daki gibidir. Tablo 6. Fotovoltaik panellerde periyodik kontroller 1 Fotovoltaik panellerin genel olarak g\u00f6zle kontrol\u00fc (K\u0131r\u0131lma, \u00c7atlama, Y\u0131lda 2 Kez Renk De\u011fi\u015fikli\u011fi, Hasar vb. durumlar\u0131na kar\u015f\u0131n kontrol\u00fc) 2 Fotovoltaik panellerin termal kontrol\u00fc Y\u0131lda 2 Kez 3 Fotovoltaik panellerin kirlilik, g\u00f6lgelenme kontrolleri Y\u0131lda 2 Kez 4 Fotovoltaik panellerin izolasyon kontrolleri Gerekti\u011finde 5 Fotovoltaik panellerin ba\u011flant\u0131 kontrolleri Y\u0131lda 2 Kez 6 Fotovoltaik panellerin kablo, konekt\u00f6r kontrolleri Y\u0131lda 2 Kez 7 Fotovoltaik panellerin IV E\u011frisi, Voc, Isc gibi elektriksel de\u011fer \u00f6l\u00e7\u00fcm Gerekti\u011finde kontrolleri 8 Dizi\/dize kablolar\u0131n\u0131n g\u00fczerg\u00e2hlar\u0131 ile yap\u0131sal hasar ve bozukluk Y\u0131lda 2 Kez durumlar\u0131na kar\u015f\u0131n kontrolleri 9 Dizi\/dize kablolar\u0131n\u0131n izolasyon \u00f6l\u00e7\u00fcmleri Y\u0131lda 1 Kez 10 Dizi\/dize kablolar\u0131n\u0131n evirici veya DC toplama panosunda Y\u0131lda 2 Kez ba\u011flant\u0131lar\u0131n\u0131n kontrolleri 11 Dizi\/dize kablolar\u0131n\u0131n \/ panel kablolar\u0131n\u0131n kablo tavas\u0131 veya kablo Y\u0131lda 2 Kez g\u00fczerg\u00e2h\u0131 \u00fczerindeki tehlike i\u00e7eren durumlara kar\u015f\u0131n kontrolleri 3.1. G\u00dcNE\u015e PANELLER\u0130NDE ARIZA \u00c7E\u015e\u0130TLER\u0130 Genel itibariyle yayg\u0131n olan fotovoltaik panel \u00e7e\u015fitleri: Monokristal, Polikristal ve \u0130nce film \u015feklindedir (\u015eekil 20). \u015eekil 20. Yayg\u0131n olarak kullan\u0131lan fotovoltaik panel \u00e7e\u015fitleri Fotovoltaik panellerde g\u00f6r\u00fclen baz\u0131 ar\u0131za \u00e7e\u015fitleri \u015fu \u015fekildedir. MOD\u00dcL 6 - 24","3.1.1. Snail Trail \u2013 Salyangoz izi Snail Trail olay\u0131, literat\u00fcrde \u2018Salyangoz izi\u2019 olarak ge\u00e7mektedir. FV mod\u00fcllerin, \u00fcretimi a\u015famas\u0131nda, nakliyesi s\u0131ras\u0131nda ya da montaj\u0131 esnas\u0131nda e\u011filip b\u00fck\u00fclmesi sebebiyle; g\u00fcne\u015fi ilk defa g\u00f6rmesinden sonra 3-5 ay i\u00e7erisinde FV mod\u00fcl \u00fczerindeki h\u00fccrelerin ba\u011flant\u0131s\u0131n\u0131 sa\u011flayan g\u00fcm\u00fc\u015f element k\u0131sm\u0131n\u0131n deformesinden dolay\u0131 olu\u015fmaktad\u0131r (\u015eekil 21). \u015eekil 21. Panellerde salyangoz izi 3.1.2. Ba\u011flant\u0131 Kutusu-Junction Box Hatalar\u0131 Junction Box, fotovoltaik panellerin ba\u011flant\u0131 kutular\u0131 olarak ge\u00e7mektedir. \u0130\u00e7erisinde bulunan diyotlar ile h\u00fccreler \u00fczerinde olu\u015fan elektriksel g\u00fcc\u00fcn tek y\u00f6nl\u00fc olarak iletilmesini sa\u011flar. \u0130nce Film panellerde genellikle ya hi\u00e7 diyot bulunmamaktad\u0131r ya da 1 adet olarak bypass diyot bulunmaktad\u0131r, monokristal ve polikristal yap\u0131daki panellerde ise genellikle 3 adet bypass diyot bulunmaktad\u0131r. Diyot say\u0131s\u0131 ve teknik \u00f6zellikleri i\u00e7in panellerin bilgi dok\u00fcman\u0131n\u0131n incelenmesi tavsiye edilir. Ba\u011flant\u0131 kutular\u0131n\u0131n i\u00e7erisinde diyot ve h\u00fccrelerden gelen ba\u011flant\u0131 hatlar\u0131n\u0131n d\u0131\u015f ortam ko\u015fullar\u0131ndan etkilenmemesi ve \u0131s\u0131nma-so\u011fuma karakteristiklerinin de\u011fi\u015fmemesi i\u00e7in kutu i\u00e7erisinde bu ba\u011flant\u0131lar\u0131n \u00fczeri bir silikon yap\u0131da madde ile kaplan\u0131r ve d\u0131\u015far\u0131dan g\u00f6z\u00fckmemektedir. Baz\u0131 panellerde geli\u015fen teknoloji ile birlikte bu kaplama maddesi kullan\u0131lmamaktad\u0131r. Junction Box hasarlar\u0131; \u2022 Mod\u00fcl\u00fcn \u00fcretim s\u00fcrecinde, ar\u0131zal\u0131\/hasarl\u0131 diyotlar\u0131n kullan\u0131lmas\u0131yla, \u2022 Diyotlar\u0131n bara lehimlemelerinin yeterince d\u00fczg\u00fcn yap\u0131lmamas\u0131yla \u015eekil 22\u2019de g\u00f6sterilen hasarlar meydana gelmektedir. \u015eekil 22. Panellerde Ba\u011flant\u0131 Kutusunda Olu\u015fan Hasarlar MOD\u00dcL 6 - 25","3.1.3. Mod\u00fcllerde Sararma-Kararma Fotovoltaik mod\u00fcllerin \u00fcretim a\u015famas\u0131nda kullan\u0131lan etilen vinil asetat (EVA) maddesinin, panel y\u00fczeyinin cam k\u0131sm\u0131nda bulunan kimyasallar ile tepkimeye girmesi sebebiyle mod\u00fcl \u00fczerindeki beyaz plastiklerde sararma ya da kararma durumlar\u0131 ortaya \u00e7\u0131kmaktad\u0131r (\u015eekil 23). Fotovoltaik mod\u00fcl\u00fcn g\u00fcne\u015fi g\u00f6rmesinden birka\u00e7 y\u0131l sonra bu durumla kar\u015f\u0131 kar\u015f\u0131ya kal\u0131nabilmektedir. \u015eekil 23. Panellerde Sararma Olu\u015fumlar\u0131 3.1.4. Fotovoltaik Panellerde K\u0131r\u0131k-\u00c7atlak Durumlar\u0131 Fotovoltaik panellerde \u00f6zellikle cam y\u00fczeylerde ya\u015fanan k\u0131r\u0131lma ve \u00e7atlama olaylar\u0131 genellikle d\u0131\u015far\u0131dan gelen etkiler ile olmaktad\u0131r (\u015eekil 24). Panellerin montaj\u0131 s\u0131ras\u0131nda, mod\u00fcl ba\u011flant\u0131 aparatlar\u0131n\u0131n belirtilen tork de\u011ferinden fazla bir de\u011fer ile s\u0131k\u0131lmas\u0131, yorgun kur\u015funlar, depremler, konstr\u00fcksiyon yap\u0131n\u0131n kaymas\u0131, \u00e7\u00f6kmesi, kar y\u00fck\u00fc, r\u00fczgar sebebiyle yerinden \u00e7\u0131kma durumlar\u0131, yabanc\u0131 cisimlerin d\u00fc\u015fmesi, ku\u015flar\u0131n y\u00fcksekten b\u0131rakt\u0131\u011f\u0131 cisimler vb. etkilerin ya\u015fanmas\u0131 sebebiyle panellerin cam y\u00fczeylerinde olu\u015fan k\u0131r\u0131lma ve \u00e7atlamalar hem \u00fcretimin g\u00fcvenli\u011fi hem de \u00fcretimin s\u00fcrd\u00fcrebilirli\u011fi \u00fczerinde bozucu etki yaratmaktad\u0131r. K\u0131r\u0131k cam, panel b\u00fct\u00fcnsellik yap\u0131s\u0131na zarar verdi\u011fi gibi, i\u00e7erisinde h\u00fccre bloklar\u0131nda elektriksel k\u0131sa devre olaylar\u0131n\u0131 da meydana getirebilece\u011fi gibi, bu tip durumlarda panellerin yenisiyle de\u011fi\u015fimi gerekmektedir. H\u00fccre bloklar\u0131n\u0131n sa\u011flam olmas\u0131 halinde bile cam de\u011fi\u015fimi veya onar\u0131m\u0131n\u0131n yap\u0131lmas\u0131 saha veya at\u00f6lye ortam\u0131nda m\u00fcmk\u00fcn de\u011fildir. Onar\u0131m\u0131n\u0131n yap\u0131lmas\u0131 ve bu \u015fekliyle kullan\u0131lmas\u0131 kesinlikle \u00f6nerilmemektedir. Ancak onar\u0131m gereklili\u011fi veya onar\u0131m\u0131n yap\u0131labilirlik durumu \u00fcretici firma ile g\u00f6r\u00fc\u015f\u00fclmelidir. \u015eekil 23. Panellerde K\u0131r\u0131k\/\u00c7atlak Olu\u015fumlar\u0131 MOD\u00dcL 6 - 26"]


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook