Important Announcement
PubHTML5 Scheduled Server Maintenance on (GMT) Sunday, June 26th, 2:00 am - 8:00 am.
PubHTML5 site will be inoperative during the times indicated!

Home Explore r_00001_ElKitap_TRready

r_00001_ElKitap_TRready

Published by Perihan Tekeli, 2023-07-10 12:21:21

Description: r_00001_ElKitap_TRready

Search

Read the Text Version

["\u015eekil 123\u2019te izolasyon \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n ba\u011flant\u0131 \u015femas\u0131 g\u00f6sterilmektedir. \u00d6l\u00e7\u00fcm yap\u0131lacak b\u00f6lgede, DC gerilimin dielektrik malzemeye uygulanmas\u0131 ile akan ak\u0131m \u00fczerinden ohm kanuna g\u00f6re diren\u00e7 de\u011feri ortaya konur. B\u00f6ylelikle potansiyel bir elektrik ar\u0131zas\u0131 \/ tehlikesi a\u00e7\u0131\u011fa \u00e7\u0131kart\u0131labilir. \u015eekil 123. \u0130zolasyon \u00d6l\u00e7\u00fcm Cihaz\u0131n\u0131n Ba\u011flant\u0131 \u015eemas\u0131 \u00d6l\u00e7\u00fcm Ad\u0131mlar\u0131: \u2022 \u00d6l\u00e7\u00fcm yap\u0131lacak alan\u0131 sistemden izole ediniz. \u2022 Dizi terminaller ba\u011flant\u0131lar\u0131n\u0131 (+ ve-) \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n ilgili terminaline ba\u011flay\u0131n\u0131z. \u2022 \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131n ilgili toprak terminalini \u00f6l\u00e7\u00fcm alan\u0131nda bulunan en yak\u0131n toprak veya metal aksam k\u0131sm\u0131na ba\u011flant\u0131s\u0131n\u0131 yap\u0131n\u0131z. \u2022 Uygulanacak DC Gerilimi, maksimum sistem geriliminin 2 kat\u0131 olacak \u015fekilde ve maksimum 1000V seviyesini a\u015fmayacak \u015fekilde, \u00f6l\u00e7\u00fcm cihaz\u0131 \u00fczerinde ayarlay\u0131n\u0131z (1500V DC sistemler i\u00e7in maksimum uygulanacak gerilim 1500V seviyesi olmal\u0131d\u0131r.). \u2022 Ba\u011flant\u0131lar\u0131 kontrol ettikten sonra ilgili G\u00fcvenlik ve ISG \u00f6nlemlerini g\u00f6zeterek, teste ba\u015flay\u0131n\u0131z. \u2022 Test sonu\u00e7land\u0131\u011f\u0131nda ve izolasyon diren\u00e7 de\u011feri elde edildikten sonra, test voltaj\u0131n\u0131n de\u015farj olmas\u0131n\u0131 (0 V\u2019a ) inmesini bekleyiniz. \u2022 De\u015farj bittikten sonra ilgili \u00f6l\u00e7\u00fcm ba\u011flant\u0131lar\u0131n\u0131 s\u00f6k\u00fcn\u00fcz. \u2022 \u00d6l\u00e7\u00fcm sonu\u00e7lar\u0131n\u0131 de\u011ferlendiriniz. \u2022 \u00d6l\u00e7\u00fcm s\u0131ras\u0131nda \u00f6l\u00e7\u00fcm cihaz\u0131nda bir hata durumu olu\u015fursa, ilgili cihaz\u0131n k\u0131lavuz y\u00f6nlendirmeleri izlenerek hata durumu ortadan kald\u0131r\u0131l\u0131r ve \u00f6l\u00e7\u00fcm tekrarlan\u0131r. \u2022 \u00d6l\u00e7\u00fcm i\u00e7in yap\u0131lan ba\u011flant\u0131lar ve uygulanan metot i\u00e7in mutlaka \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131n k\u0131lavuz y\u00f6nergelerine bak\u0131n\u0131z. \u2022 FV dizilerde uygulanacak gerilim kademeleri ve minimum istenen izolasyon diren\u00e7 de\u011ferleri IEC 62446 \u2018ya g\u00f6re Tablo 9\u2019daki gibidir. MOD\u00dcL 6 - 77","Tablo 9. IEC Standartlar\u0131nda Uygulanan Gerilim ve Beklenen Minimum \u0130zolasyon Diren\u00e7 De\u011feri MOD\u00dcL 6 - 78","KONU 7 KORUMA VE \u00d6L\u00c7\u00dc ELEMANLARININ BAKIM VE ONARIMI 7.1. KORUMA VE \u00d6L\u00c7\u00dc ELEMANLARI VE \u00d6ZELL\u0130KLER\u0130 7.1.1. Y\u0131ld\u0131r\u0131mdan Korunma Sistemleri Y\u0131ld\u0131r\u0131mdan korunma sistemleri ile ilgili Temel kavramlar ve tan\u0131mlamalar a\u015fa\u011f\u0131da verilmektedir. Y\u0131ld\u0131r\u0131ml\u0131k: Y\u0131ld\u0131r\u0131m olay\u0131 basit bir anlat\u0131m ile bulut ile yery\u00fcz\u00fc aras\u0131nda meydana gelen elektrik bo\u015falmas\u0131d\u0131r. Bu elektrik bo\u015falmas\u0131 buluttan yere do\u011fru olabildi\u011fi gibi, yerden buluta do\u011fru da ger\u00e7ekle\u015febilmektedir. Y\u0131ld\u0131r\u0131m gerilim potansiyeli 10-100 milyon volt seviyesi aral\u0131\u011f\u0131nda olabilmekte, darbe ak\u0131m\u0131 30.000 A seviyesine ula\u015fabilmektedir. Y\u0131ld\u0131r\u0131mdan korunma y\u00f6ntemleri \/ sistemleri (YKS): Y\u0131ld\u0131r\u0131mdan korunma y\u00f6ntemleri olarak i\u00e7 y\u0131ld\u0131r\u0131mdan korunma sistemi ve d\u0131\u015f y\u0131ld\u0131r\u0131mdan korunma sistemi ba\u015fl\u0131klar\u0131n\u0131 ele almam\u0131z gerekmektedir. \u2022 D\u0131\u015f y\u0131ld\u0131r\u0131mdan korunma sistemi: Yakalama ucu, indirme iletkeni ve topraklama sistemlerinden olu\u015fmaktad\u0131r. \u2022 \u0130\u00e7 Y\u0131ld\u0131r\u0131mdan Korunma Sistemleri: Korunan hacmin i\u00e7inde, y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131n elektromanyetik etkilerini azaltmak \u00fczere d\u0131\u015f YKS i\u00e7in verilenlere ek olarak al\u0131nacak t\u00fcm \u00f6nlemlerdir. Korunan hacim: Bir yap\u0131n\u0131n veya b\u00f6lgenin bu Y\u00f6netmelik kurallar\u0131na uygun olarak y\u0131ld\u0131r\u0131m etkilerine kar\u015f\u0131 korunmu\u015f b\u00f6l\u00fcm\u00fcd\u00fcr. Yakalama ucu sistemi: D\u0131\u015f YSK\u2019nin, y\u0131ld\u0131r\u0131m bo\u015falmas\u0131n\u0131 yakalamak i\u00e7in kullan\u0131lan b\u00f6l\u00fcm\u00fcd\u00fcr. \u0130ndirme iletkeni sistemi: D\u0131\u015f YSK\u2019nin, y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131 yakalama ucu sisteminden, topraklama sistemine ge\u00e7irmek \u00fczere kullan\u0131lan b\u00f6l\u00fcm\u00fcd\u00fcr. Topraklama sistemi: D\u0131\u015f YSK\u2019nin, y\u0131ld\u0131r\u0131m ak\u0131m\u0131n\u0131 topra\u011fa iletmek ve yaymak \u00fczere kullan\u0131lan b\u00f6l\u00fcm\u00fcd\u00fcr. 7.1.2. Koruma Elemanlar\u0131 a) Termik Manyetik \u015ealter Devre kesici olarak kullan\u0131lmaktad\u0131rlar. Termik ve Manyetik Koruma sa\u011flarlar. Ba\u011fl\u0131 oldu\u011fu elektrik devresinden a\u015f\u0131r\u0131 ak\u0131m veya k\u0131sa devre olu\u015fmas\u0131 durumunda devreyi keserek sistemi korur. Termik Koruma: Termik ortamdaki s\u0131cakl\u0131k de\u011fi\u015fimleri sebebiyle kontaklar\u0131n\u0131 a\u00e7an ya da kapatan bir r\u00f6le \u00e7e\u015fididir. A\u015f\u0131r\u0131 ak\u0131m durumlar\u0131nda bimetal olan ve s\u0131cakl\u0131k karakteristikleri farkl\u0131 iki metal, \u00fczerinden ge\u00e7en ak\u0131m miktar\u0131na g\u00f6re formunu de\u011fi\u015ftirerek devrenin a\u00e7\u0131lmas\u0131n\u0131 sa\u011flar. K\u0131sacas\u0131 termik r\u00f6le yard\u0131m\u0131yla TM\u015e kontaklar\u0131 a\u00e7arak devreyi keser. Manyetik Koruma: Sistemde ya\u015fanan k\u0131sa devre durumlar\u0131nda ortaya \u00e7\u0131kan k\u0131sa devre ak\u0131mlar\u0131 TM\u015e i\u00e7erisinde manyetik alan olu\u015fturarak yine TM\u015e i\u00e7erisindeki bobin mekanizmas\u0131n\u0131n aktif olmas\u0131n\u0131 sa\u011flar. K\u0131sa devre durumlar\u0131nda, ind\u00fcklenen manyetik ak\u0131 ve bobin sistemi yard\u0131m\u0131yla devre kesilmi\u015f olur. b) Ka\u00e7ak Ak\u0131m Koruma Sigortas\u0131 (Ka\u00e7ak Ak\u0131m R\u00f6lesi) N\u00f6tr kullan\u0131lan sistemlerde ka\u00e7ak ak\u0131m\u0131n \u00f6l\u00e7\u00fclmesi ve sistemin\/cihaz\u0131n korumaya al\u0131nmas\u0131 b\u00fcy\u00fck \u00f6nem ta\u015f\u0131maktad\u0131r. Ka\u00e7ak Ak\u0131m R\u00f6lesi bu y\u00f6n\u00fcyle Fotovoltaik G\u00fc\u00e7 Sistemleri elektrik devrelerinde yayg\u0131n olarak kullan\u0131lmaktad\u0131r. MOD\u00dcL 6 - 79","Ka\u00e7ak Ak\u0131m\u0131n alg\u0131lanarak devre kesicilere sinyal g\u00f6nderilmesi mant\u0131\u011f\u0131yla \u00e7al\u0131\u015fma yap\u0131s\u0131na sahip olan bu cihazlarda, ka\u00e7ak ak\u0131m\u0131n alg\u0131lanmas\u0131 i\u00e7in toroid bir ak\u0131m trafosu i\u00e7erisinden ge\u00e7irilen faz ve n\u00f6tr kablolar\u0131 aras\u0131nda bir ak\u0131m fark\u0131 olu\u015fmas\u0131na ba\u011fl\u0131 olarak ind\u00fcklenen manyetik ak\u0131 ile devre \u00fczerindeki kontaklar\u0131n a\u00e7mas\u0131 prensibi ile \u00e7al\u0131\u015f\u0131r. c) Parafudrlar Elektriksel sistemi \/ cihazlar\u0131 a\u015f\u0131r\u0131 gerilim darbelerine kar\u015f\u0131 koruyan, devreye paralel olarak ba\u011flanan ve normal \u015fartlarda pasif \u00f6zellik g\u00f6steren, a\u015f\u0131r\u0131 gerilim durumlar\u0131 olu\u015fmad\u0131\u011f\u0131 zaman i\u00e7 direnci y\u00fcksek olan koruma elemanlar\u0131d\u0131r. Parafudrlar normal i\u015fletme halinden yal\u0131tkand\u0131r ancak a\u015f\u0131r\u0131 gerilim veya ani gerilim darbesi geldi\u011finde iletken hale ge\u00e7erler ve ald\u0131klar\u0131 darbeyi topra\u011fa iletirler. Yap\u0131s\u0131 gere\u011fi normal gerilim alt\u0131nda y\u00fcksek diren\u00e7 etkisi g\u00f6sterirken, ani gerilim darbesi ile diren\u00e7 de\u011feri minimuma inerek, ilgili bozucu etkiyi topra\u011fa iletmek i\u00e7in en k\u0131sa yol haline d\u00f6n\u00fc\u015f\u00fcrler. Y\u0131ld\u0131r\u0131m darbelerine, i\u00e7 a\u015f\u0131r\u0131 gerilim darbelerine kar\u015f\u0131n koruma sa\u011flarlar ve bulunduklar\u0131 devre ve devre elemanlar\u0131n\u0131 bozucu etkilerden korurlar. Parafudrlar s\u00fcrekli a\u015f\u0131r\u0131 gerilimlere kar\u015f\u0131 de\u011fil, ani gerilim darbelerine kar\u015f\u0131n koruma yaparlar. S\u00fcrekli a\u015f\u0131r\u0131 gerilim alt\u0131nda, faz\/n\u00f6tr ters ba\u011flant\u0131lar\u0131nda, n\u00f6tr kopmas\u0131 gibi durumlar\u0131 k\u0131sa devre g\u00f6r\u00fcr ve ilgili devrede hasara sebebiyet verebilir. Bu sebeple parafudrlar\u0131 k\u0131sa devrelere kar\u015f\u0131 koruyacak bir devre kesici ile beraber kullan\u0131lmas\u0131 gerekir. Parafudr \u00f6ncesi kullan\u0131lacak kesicinin k\u0131sa devre dayan\u0131m\u0131, en az ilgili tesisat\u0131n k\u0131sa devre dayan\u0131m\u0131 kadar olmal\u0131d\u0131r. Parafudrlar\u0131n toprak ile ba\u011flant\u0131 hatt\u0131 en k\u0131sa yoldan ana toprak e\u015f potansiyel baras\u0131na ba\u011flanmal\u0131 ve olabildi\u011fince koruma \u00fcr\u00fcnlerinden ge\u00e7en besleme ve sinyal kablolar\u0131ndan uzak tutulmal\u0131d\u0131r. Parafudr Koruma S\u0131n\u0131flar\u0131: \u2022 B s\u0131n\u0131f\u0131 (Tip I ): E\u011fer sistemde ve sisteme 50 metre civar\u0131 yak\u0131nlarda y\u0131ld\u0131r\u0131ma kar\u015f\u0131n paratoner uygulamas\u0131 varsa, B s\u0131n\u0131f\u0131 parafudr se\u00e7imi yap\u0131lmal\u0131d\u0131r. B s\u0131n\u0131f\u0131 parafudrlar, al\u00e7ak gerilim devresinin giri\u015f k\u0131sm\u0131na yak\u0131n bir yerde konumland\u0131r\u0131lmalar\u0131 gerekmektedir. Binalarda, binaya gelen besleme hatt\u0131n\u0131n, binaya girdi\u011fi en yak\u0131n noktada kullan\u0131mlar\u0131 buna \u00f6rnek verilebilir. \u2022 C S\u0131n\u0131f\u0131 (Tip II): \u0130\u00e7 kaynaktan olu\u015fan a\u015f\u0131r\u0131 gerilimlere kar\u015f\u0131 koruma yapabilmek i\u00e7in tesisattaki her bir da\u011f\u0131t\u0131m panosuna ilave olarak C s\u0131n\u0131f\u0131 parafudr yerle\u015ftirilmelidir. Al\u00e7ak gerilim tesisleri i\u00e7in a\u015f\u0131r\u0131 gerilim s\u0131n\u0131rlay\u0131c\u0131s\u0131 olarak parafudrlar kullan\u0131l\u0131r. Binalarda elektrik sayac\u0131 sonras\u0131 kullan\u0131mlar \u00f6rnek verilebilir. \u2022 D S\u0131n\u0131f\u0131 (Tip III): Elektronik ve hassas cihazlar\u0131n, i\u00e7 a\u015f\u0131r\u0131 gerilimlere kar\u015f\u0131 korunmas\u0131 i\u00e7in kullan\u0131l\u0131rlar. Hassas cihazlar\u0131n , Tip II parafudrlar\u0131n oldu\u011fu da\u011f\u0131t\u0131m panosuna uzakl\u0131\u011f\u0131 30 m\u2019yi a\u015fan durumlarda ek olarak Tip III uygulamas\u0131 yap\u0131l\u0131r. \u2022 B+C S\u0131n\u0131f\u0131 (Tip I + Tip II): B ve C s\u0131n\u0131f\u0131 parafudrlar\u0131n bir kombinasyonu olan bu s\u0131n\u0131f ana da\u011f\u0131t\u0131m panosu ile tali da\u011f\u0131t\u0131m panosu aras\u0131 mesafenin 10 metreyi a\u015fmas\u0131 durumunda kullan\u0131lmas\u0131 tavsiye edilmektedir. 7.1.3. \u00d6l\u00e7\u00fc Elemanlar\u0131 a) Analiz\u00f6r Enerji Analiz\u00f6rleri, Fotovoltaik G\u00fc\u00e7 Sistemlerinde yayg\u0131n olarak, hem al\u00e7ak gerilim hem de y\u00fcksek gerilim taraf\u0131nda kullan\u0131lan, enerji ve di\u011fer formlar\u0131n\u0131n s\u00fcrekli olarak izlenebilmesi ve kay\u0131t alt\u0131na al\u0131nabilmesine imk\u00e2n sa\u011flayan \u00f6l\u00e7\u00fcm cihazlar\u0131d\u0131r. G\u00f6r\u00fcn\u00fcr Enerji, Aktif ve Reaktif Enerji, Faz ak\u0131mlar\u0131, Faz Gerilimleri, Hat Ak\u0131mlar\u0131, Hat Gerilimleri, Talep (Demand), Harmonik Bozulmalar, G\u00fc\u00e7 Fakt\u00f6r\u00fc gibi bir\u00e7ok elektriksel bile\u015feni \u00f6l\u00e7erek, de\u011ferleri kay\u0131t alt\u0131nda tutabilmekte, hata ve bozucu etkiler kar\u015f\u0131s\u0131nda olaya ili\u015fkin detayl\u0131 analiz sa\u011flayabilmektedir. MOD\u00dcL 6 - 80","Haberle\u015fme protokolleri sayesinde uzaktan eri\u015fim imkan\u0131 ile analiz\u00f6rdeki verilere ula\u015f\u0131labilmektedir. b) Saya\u00e7lar Elektrik sayac\u0131, temel olarak t\u00fcketilen \/ \u00fcretilen enerji miktar\u0131n\u0131 \u00f6l\u00e7mek amac\u0131yla tasarlanm\u0131\u015f \u00f6nemli bir ara\u00e7t\u0131r. Elektriksel g\u00fcc\u00fcn zaman i\u00e7erisindeki miktar\u0131n\u0131 ve da\u011f\u0131l\u0131m\u0131n\u0131 \u00f6l\u00e7en bu cihazlarda enerji t\u00fcketim\/\u00fcretim miktarlar\u0131n\u0131n birimi Wh olarak ifade edilmektedir. 7.2. KORUMA VE \u00d6L\u00c7\u00dc ELEMANLARINDA ARIZA \u00c7E\u015e\u0130TLER\u0130 7.2.1. Y\u0131ld\u0131r\u0131mdan Korunma Sistemlerinde Olu\u015fan Ar\u0131zalar a) Parafudr Ar\u0131zalar\u0131 Al\u00e7ak gerilim panolar\u0131nda y\u0131ld\u0131r\u0131m, a\u015f\u0131r\u0131 gerilim kaynakl\u0131 bozucu \/ hasar etkilerine kar\u015f\u0131n parafudr kullan\u0131lmaktad\u0131r. Parafudrlar\u0131n darbe yakalamas\u0131 sonucunda ye\u015fil renkli g\u00f6sterge k\u0131s\u0131mlar\u0131 k\u0131rm\u0131z\u0131ya d\u00f6nmektedir. Bu noktada bu parafudrlar\u0131n de\u011fi\u015fmesi gerekmektedir (\u015eekil 124). MOD\u00dcL 6 - 81","\u015eekil 123. Parafudr Kontrolleri ve Ar\u0131zalar\u0131 7.2.2. TM\u015e ve Ka\u00e7ak Ak\u0131m Koruma Sigorta Gruplar\u0131nda olu\u015fan Ar\u0131zalar Sigorta koruma elemanlar\u0131nda olu\u015fan ar\u0131zalar\u0131n geneli kablo ba\u011flant\u0131lar\u0131ndaki gev\u015feklik (\u015eekil 125), TM\u015e (\u015eekil 126), -Ka\u00e7ak Ak\u0131m Koruma Sigortas\u0131n\u0131n (\u015eekil 127) i\u00e7 yap\u0131s\u0131ndan kaynakl\u0131 bozukluklar harici olaylar (su ile temas, kemirgen veya yabani hayvanlar\u0131n zarar vermesi vb. (\u015eekil 128)) ile meydana gelmektedir. \u015eekil 124. TM\u015e Kablo Ba\u011flant\u0131lar\u0131nda Hasarlar \u015eekil 126. \u00c7evresel Etkenler ile Beraber TM\u015e \u0130\u00e7yap\u0131s\u0131nda Yap\u0131sal Bozukluk ve Hasar \u015eekil 127. Ka\u00e7ak Ak\u0131m Koruma Sigortas\u0131n\u0131n Hasar Almas\u0131 MOD\u00dcL 6 - 82","\u015eekil 128. Kemirgenler Taraf\u0131ndan Hasar Verilen Durumlar 7.2.3. Analiz\u00f6r \/ Saya\u00e7 Ar\u0131zalar\u0131 Analiz\u00f6r ve Saya\u00e7 gruplar\u0131nda genellikle ar\u0131za ya\u015fanma olas\u0131l\u0131\u011f\u0131 d\u00fc\u015f\u00fckt\u00fcr. Ba\u011flant\u0131 hatalar\u0131, a\u015f\u0131r\u0131 gerilim, k\u0131sa devre ak\u0131mlar\u0131 vb. durumlarda ba\u011flant\u0131 noktalar\u0131ndan zarar g\u00f6rebilir, hasar alabilirler (\u015eekil 129). Bu tip cihazlar\u0131n koruma sigortalar\u0131 ile \u00f6n koruma yapmak \u00f6nemlidir. \u015eekil 129. Analiz\u00f6r Hasarlar\u0131 7.2.4. Ak\u0131m\/Gerilim \u00d6l\u00e7\u00fc Trafolar\u0131 Ar\u0131zalar\u0131 Trafolarda ya\u015fanan ar\u0131zalar\u0131n genellikle \u015febeke dalgalanmalar\u0131, doyma noktas\u0131na ula\u015fmas\u0131, ani a\u015f\u0131 gerilim, k\u0131sa devre durumlar\u0131, toprak ar\u0131zas\u0131 gibi sebepler ile meydana gelmekte, ar\u0131za ya\u015fanma s\u0131kl\u0131\u011f\u0131 olduk\u00e7a d\u00fc\u015f\u00fck ekipmanlard\u0131r. Ak\u0131m\/ Gerilim \u00d6l\u00e7\u00fc Trafolar\u0131ndan ya\u015fanan ar\u0131zalardan baz\u0131lar\u0131 \u015eekil 130-132\u2019de g\u00f6sterilmektedir. MOD\u00dcL 6 - 83","\u015eekil 130. Al\u00e7ak Gerilim Ak\u0131m \u00d6l\u00e7\u00fc Trafolar\u0131nda Is\u0131nma ve Cihaz Kaynakl\u0131 Ya\u015fanan Hasarlar \u015eekil 131. Y\u00fcksek Gerilim \/ Ak\u0131m \u00d6l\u00e7\u00fc Transformat\u00f6rlerinde \u015eebeke Kaynakl\u0131 Ya\u015fanan Hasar \u015eekil 132. Y\u00fcksek Gerilim \/ Gerilim \u00d6l\u00e7\u00fc Transformat\u00f6rlerinde \u015eebeke Kaynakl\u0131 Ya\u015fanan Hasar MOD\u00dcL 6 - 84","7.3. KORUMA VE \u00d6L\u00c7\u00dc ELEMANLARINDA BAKIM VE ONARIM \u00d6l\u00e7\u00fc ve Koruma ekipmanlar\u0131n\u0131n ba\u011flant\u0131lar\u0131nda g\u00f6rsel, el aletleri ile ve cihazlar ile durum kontrolleri yap\u0131labilir (\u015eekil 133). Ba\u011flant\u0131 gev\u015feklik durumlar\u0131nda yine diren\u00e7 etkisi ile \u0131s\u0131nma problemleri termal kontrol ile kolayl\u0131kla tespit edilebilmektedir (\u015eekil 134). Ba\u011flant\u0131lar\u0131n s\u0131k\u0131l\u0131k kontrolleri, termal kontroller, kablolar\u0131n pabu\u00e7 k\u0131s\u0131mlar\u0131nda ve izolasyonlu k\u0131s\u0131mlar\u0131nda sa\u011flaml\u0131k kontrolleri, ekipman montaj yerinin uygunluk ve temizlik kontrolleri ve di\u011fer aksakl\u0131klar\u0131n tespiti i\u00e7in g\u00f6zle kontrollerin periyodik olarak yap\u0131lmas\u0131 gereklidir. \u015eekil 133. Ba\u011flant\u0131lar\u0131n kontrolleri ve elektriksel de\u011fer \u00f6l\u00e7\u00fcmleri \u015eekil 133. Ekipmanlarda ve ba\u011flant\u0131 noktalar\u0131nda termal kontrol ile hasar-ar\u0131za tespiti MOD\u00dcL 6 - 85","7.3.1. Y\u0131ld\u0131r\u0131mdan Korunma Sistemlerinde Bak\u0131m Onar\u0131m Y\u0131ld\u0131r\u0131mdan Korunma Sistemlerinde, uygulanan sistem \u00e7e\u015fidine g\u00f6re kontroller detayland\u0131r\u0131labilmektedir. a) Franklin \u00e7ubuklar\u0131 ile Faraday Kafesi Sistemi \u2022 Franklin \u00e7ubuklar\u0131n\u0131n herhangi bir deformasyona u\u011fray\u0131p u\u011framad\u0131\u011f\u0131, ba\u011flant\u0131 noktalar\u0131n\u0131n sa\u011flam olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 \u0130ndirme iletkenlerinin kafes iletkenleri ile irtibat\u0131 kontrol edilmelidir. \u2022 \u0130ndirme iletkenlerinin e\u015f potansiyel bara- toprak irtibat\u0131n\u0131n kontrol edilmesi gereklidir. \u2022 \u0130ndirme \u0130letkenleri ile ba\u011fland\u0131klar\u0131 e\u015f potansiyel-toprak baras\u0131 ile irtibat\u0131na ili\u015fkin s\u00fcreklilik testi uygulanmal\u0131d\u0131r. \u2022 Topraklama Diren\u00e7 testi uygulanmal\u0131d\u0131r. \u2022 \u0130ni\u015f \u0130letkenlerinde herhangi bir oksitlenme veya deformasyon olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 Ba\u011flant\u0131 klemens \/ aparat gruplar\u0131n\u0131n deformasyon ve ba\u011flant\u0131 kontrollerinin yap\u0131lmas\u0131 gereklidir. \u2022 \u0130ni\u015f iletkenlerinin izoleli olup olmad\u0131\u011f\u0131, izole k\u0131s\u0131mlar\u0131nda sorun olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 S koruma mesafesi kontrolleri yap\u0131lmal\u0131d\u0131r. b) Franklin \u00e7ubuklar\u0131 ile Yuvarlanan K\u00fcre Sistemi \u2022 Franklin \u00e7ubuklar\u0131n\u0131n herhangi bir deformasyona u\u011fray\u0131p u\u011framad\u0131\u011f\u0131, ba\u011flant\u0131 noktalar\u0131n\u0131n sa\u011flam olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 Franklin \u00e7ubuklar\u0131n\u0131n ba\u011fl\u0131 olduklar\u0131 ini\u015f iletkenleri ve ini\u015f sistemlerinin toprak ile irtibat\u0131 kontrol edilmelidir. \u2022 \u0130ni\u015f iletkenlerinin \/ sistemlerinin herhangi bir deformasyona sahip olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 Topraklama iletkenleri ile \/ e\u015f potansiyel sistem ile temas\u0131n sa\u011fland\u0131\u011f\u0131 yap\u0131n\u0131n kontrol edilmesi gereklidir. \u2022 Ba\u011flant\u0131 klemens \/ aparat gruplar\u0131n\u0131n deformasyon ve ba\u011flant\u0131 irtibat kontrollerinin yap\u0131lmas\u0131 gereklidir. c) \u0130\u00e7 Y\u0131ld\u0131r\u0131ml\u0131k ve \u0130\u00e7 A\u015f\u0131r\u0131 Gerilim Darbelerine Kar\u015f\u0131n Koruma Sa\u011flayan Parafudr Sistemleri \u2022 Periyodik olarak parafudrlar\u0131n emre amade olduklar\u0131n\u0131n, herhangi bir ar\u0131zaya ge\u00e7me durumunun olup olmad\u0131\u011f\u0131 kontrol edilmelidir. d) Aktif Paratoner Sistemi \u2022 \u0130ni\u015f iletkenlerinin S koruma mesafesine dikkat edilmelidir. \u2022 \u0130ni\u015f iletkenlerinin izoleli olarak indirilip indirilmemesine dikkat edilmelidir. \u2022 \u0130ni\u015f iletkenlerinin izoleli korumas\u0131nda deformasyon vb. durumlar\u0131n olup olmad\u0131\u011f\u0131 kontrol edilmelidir. \u2022 \u0130ni\u015f iletkenlerinin irtibat noktalar\u0131ndaki ba\u011flant\u0131 ve deformasyonlara kar\u015f\u0131n kontrol edilmesi gereklidir. \u2022 \u0130ni\u015f iletkenlerinin, sistem e\u015f potansiyel bara noktas\u0131yla irtibat\u0131n\u0131n sa\u011flan\u0131p sa\u011flanmad\u0131\u011f\u0131n\u0131n kontrolleri yap\u0131lmal\u0131d\u0131r. \u2022 S\u00fcreklilik ve toprak diren\u00e7 \u00f6l\u00e7\u00fcmleri yap\u0131lmal\u0131d\u0131r. MOD\u00dcL 6 - 86","KONU 8 HABERLE\u015eME S\u0130STEMLER\u0130N\u0130N BAKIM VE ONARIMI 8.1. HABERLE\u015eME S\u0130STEMLER\u0130 VE \u00d6ZELL\u0130KLER\u0130 Fotovoltaik G\u00fc\u00e7 Sistemlerinin en \u00f6nemli par\u00e7alar\u0131ndan bir tanesi izleme\/SCADA sistemleridir. SCADA terimi, \u0130ngilizce \u201cSupervisory Control and Data Acquisition\u201d ifadesinin k\u0131saltmas\u0131d\u0131r. \u201cMerkezi Denetim ve Veri Toplama Sistemi\u201d olarak ifade edilmektedir. End\u00fcstriye bir\u00e7ok alanda SCADA sistemleri, prosesin dinamik olarak izlenip takip edilmesine, proses i\u00e7erisindeki birimlerin kontrol ve denetimin sa\u011flanmas\u0131na, toplanan verilerin kay\u0131t alt\u0131na al\u0131nabilmesine ve istenildi\u011fi zaman bu veri paketlerinin analiz edilmesine imkan sa\u011flayan sistemlerdir. \u00d6rnek SCADA Sistemleri \u015eekil 135 ve \u015eekil 136\u2019da g\u00f6sterilmektedir. \u015eekil 134. \u00d6rnek Scada \u015eemas\u0131-I SCADA birimi genellikle 3 temel birimden olu\u015fmaktad\u0131r. \u2022 Merkezi \/ Ana Kontrol Birimi (MTU \/MCU \u2013 Master Terminal Unit \/ Master Control Unit) \u2022 Uzak Terminal Birimi (RTU-Remote Terminal Unit) \u2022 \u0130leti\u015fim Sistemi Merkezi Kontrol Birimi: Uzak terminal birimlerinden ya da ak\u0131ll\u0131 elektronik cihazlardan gelen veri paketlerini toplar ve yorumlayarak i\u015fletilmesi sa\u011flar. Yorumlanan veriler ve elde edilen sonu\u00e7lara g\u00f6re hedeflenen noktalara komutlar g\u00f6ndererek denetleyici mekanizmalar\u0131 \u00e7al\u0131\u015ft\u0131r\u0131r. Uzak Terminal Birimi: SCADA sisteminin en \u00f6nemli birimlerinden olan RTU\u2019lar kontrol ve izlenen sisteme dair veri paketlerini toplayan, depolayan ve ihtiya\u00e7 halinde bu paketleri kontrol birimine g\u00f6nderen birimdir. RTU\u2019lar ba\u011fl\u0131 olduklar\u0131 prosese ili\u015fkin baz\u0131 \u00f6l\u00e7\u00fcmleri yapabilir bu de\u011ferleri yorumlayarak denetim mekanizmas\u0131n\u0131 \u00e7al\u0131\u015ft\u0131rabilir veya alarm durumlar\u0131 yaratabilir. MOD\u00dcL 6 - 87","\u015eekil 136. \u00d6rnek SCADA \u015eemas\u0131-II RTU birimleri veri paketi toplama ve depolama g\u00f6revleri yans\u0131ra, periyodik ve tekrarl\u0131 bilgiler toplar ve bu bilgileri denetler. Kontrol ve kumanda \u00e7\u0131k\u0131\u015f\u0131 ile RTU, uzaktan kontrol i\u015flevini \u00f6rne\u011fin, elektrik tesislerinde bir devre kesiciyi a\u00e7ma-kapama gibi kararl\u0131 bir \u015fekilde ger\u00e7ekle\u015ftirebilir. \u015eekil 137\u2019de Fotovoltaik g\u00fc\u00e7 sistemlerinde basit izleme \u015femas\u0131 \u00f6rne\u011fi g\u00f6sterilmektedir. \u015eekil 137. Fotovoltaik G\u00fc\u00e7 Sistemlerinde Basit \u0130zleme \u015eemas\u0131 MOD\u00dcL 6 - 88","\u0130leti\u015fim Sistemi: Veri formatlar\u0131n\u0131n ve bilgi al\u0131\u015fveri\u015finin zamanlamas\u0131n\u0131 d\u00fczenleyen kurallar dizisine protokol denir. Kar\u015f\u0131l\u0131kl\u0131 \u00e7al\u0131\u015fma i\u00e7in bilgisayarlar veya RTU\u2019lar\u0131n (Remote Terminal Unit) ayn\u0131 protokol\u00fc uygulamalar\u0131 zorunludur. Fotovoltaik Sistemlerde kullan\u0131lan SCADA sistemlerinde genellikle, Modbus protokol\u00fc yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Modbus TCP\/IP, Modbus RTU, IEC 60870-5-104, IEC 60870-5-101, IEC 60870-5- 103, IEC 61850 gibi protokollerde yer almaktad\u0131r. \u2022 Modbus TCP\/IP: Modbus, 1979 y\u0131l\u0131nda Modicon taraf\u0131ndan PLC\u2019ler ile kullan\u0131lmak i\u00e7in geli\u015ftirilen bir seri haberle\u015fme protokol\u00fcd\u00fcr. Modbus TCP\/IP, Modbus mesaj yap\u0131s\u0131n\u0131n verilerini uyumlu cihazlar aras\u0131nda ta\u015f\u0131mak i\u00e7in TCP\/IP ve Ethernet kullan\u0131r. Yani, Modbus TCP\/IP fiziksel bir a\u011f\u0131 (Ethernet), bir a\u011f standard\u0131yla (TCP\/IP) verileri temsil eden standart bir y\u00f6ntem. Modbus TCP\/IP mesaj\u0131 basit\u00e7e bir Ethernet TCP\/IP paketinde kaps\u00fcllenmi\u015f bir Modbus ileti\u015fimidir. Modbus TCP\/IP otomasyon cihazlar\u0131n\u0131n denetimi ve kontrol\u00fc ama\u00e7l\u0131 tasarlanan kullan\u0131m\u0131 basit olan bir protokold\u00fcr. Klasik internet a\u011f topolojisine g\u00f6re haberle\u015fme sunan bu protokol standart olarak kullan\u0131lan internet kartlar\u0131 ile 100 Mbps h\u0131z ile veri aktar\u0131m\u0131 yapar. TCP\/IP protokol\u00fc ile \u00e7ok say\u0131da ba\u011flant\u0131 yap\u0131labilir. Sunucu\/istemci cihazlar aralar\u0131nda ba\u011flant\u0131 kurulur ve veri aktar\u0131m\u0131 ger\u00e7ekle\u015fir. Herhangi bir cihaz istemci veya sunucu olabilece\u011fi gibi sistemde bir\u00e7ok sunucu veya istemci olabilir. TCP\/IP protokol\u00fcnde verilerin iletim h\u0131z\u0131 cihazlarda kullan\u0131lan i\u015flemci ve internet kart\u0131 t\u00fcr\u00fcne ba\u011fl\u0131 olarak de\u011fi\u015fmektedir. \u2022 Modbus RTU: Bu protokol master\/slave mimarisine g\u00f6re d\u00fczenlenmi\u015f seri haberle\u015fme protokollerini kullan\u0131r. Kullan\u0131m kolayl\u0131\u011f\u0131 ve g\u00fcvenilirlik nedeniyle yayg\u0131n olarak kullan\u0131l\u0131r. \u0130ki bitlik veriler halinde yollanan mesajlar\u0131n g\u00fcvenli iletimi i\u00e7in kullan\u0131lan 16 bitlik CRC (hata kontrol mekanizmas\u0131) ile basitlik ve g\u00fcvenilirlik sa\u011flanm\u0131\u015f olur. \u2022 IEC 60870\u20135\u2013104: IEC (International Electrotechnical Commission) taraf\u0131ndan SCADA\u2019y\u0131 uzaktan kontrol ve verilerin iletimi i\u00e7in olu\u015fturulmu\u015ftur. G\u00fc\u00e7 sistemi izleme kontrol ve ilgili ileti\u015fim i\u00e7in tasarlanm\u0131\u015ft\u0131r. IEC 104 telekontrol aletleri ve TCP\/IP tabanl\u0131 a\u011fda izleme ve co\u011frafi yayg\u0131n s\u00fcre\u00e7leri kontrol ederken ki h\u0131zl\u0131 veri aktar\u0131m\u0131nda kullan\u0131lan sistem i\u00e7in bir standartt\u0131r. IEC 60870\u20135\u2013101, IEC 608\u20135\u2013104\u2019 \u00fcn eski halidir. \u2022 IEC61850: IEC61850 protokol\u00fc ile ama\u00e7, bu belli ko\u015fullar\u0131 sa\u011flamak ihtiyac\u0131n\u0131 da ortadan kald\u0131rmak ve Ethernet h\u0131z\u0131nda \u201cplug and play\u201d kullan\u0131m kolayl\u0131\u011f\u0131na sahip bir ortak protokol\u00fc enerji otomasyonunun hizmetine sunmakt\u0131r. B\u00fct\u00fcn bunlar\u0131n yan\u0131nda, enerji otomasyonu temel ihtiya\u00e7lar\u0131n\u0131 da eksiksiz olarak kar\u015f\u0131layabilmek esast\u0131r. 1995 y\u0131l\u0131ndan bu yana, 14 ayr\u0131 \u00fclkeden toplam 60 m\u00fchendis IEC 61850 protokol\u00fcn\u00fcn geli\u015ftirilmesi i\u00e7in \u00e7al\u0131\u015fmaktad\u0131r. 2004 y\u0131l\u0131 i\u00e7erisinde, protokol t\u00fcm d\u00fcnyaya tan\u0131t\u0131lm\u0131\u015f ve fiili olarak kullan\u0131lmaya ba\u015flanm\u0131\u015ft\u0131r. Da\u011f\u0131t\u0131m ve trafo merkezleri ekipmanlar\u0131 aras\u0131ndaki haberle\u015fmeyi tan\u0131mlayan IEC 61850 protokol\u00fc \u00f6nceki protokollerden farkl\u0131 olarak, esnek ve gelece\u011fe d\u00f6n\u00fck olarak geli\u015ftirilmi\u015ftir. Fotovoltaik G\u00fc\u00e7 Santrallerin izleme sistemleri a\u015fa\u011f\u0131da yer alan datalar\u0131 sa\u011flayabilir olmas\u0131, izleme, kontrol ve denetim s\u00fcre\u00e7lerinin iyi yap\u0131labilir olmas\u0131na olanak sa\u011flayacakt\u0131r. \u2022 SCADA sisteminin sa\u011flayaca\u011f\u0131 grafik analizleri dakikal\u0131k, saatlik, g\u00fcnl\u00fck, haftal\u0131k, ayl\u0131k ve y\u0131ll\u0131k olarak se\u00e7ilebilir olmal\u0131 \u2022 Grafik analizleri, alarmlar ve olay kay\u0131tlar\u0131 en az 3 senelik ge\u00e7mi\u015f tarihli g\u00f6r\u00fcnt\u00fclenebilir olmal\u0131 \u2022 Fotovoltaik G\u00fc\u00e7 Sisteminde yer alan eviricilerden minimum olarak a\u015fa\u011f\u0131daki bilgiler okunabilir ve g\u00f6sterilebilir olmal\u0131 o DC Ak\u0131m\u0131 o AC Ak\u0131m\u0131 o DC Gerilimi o AC Gerilimi o DC Anl\u0131k G\u00fcc\u00fc o Aktif, Reaktif ve G\u00f6r\u00fcn\u00fcr G\u00fc\u00e7 o Frekans o G\u00fc\u00e7 Fakt\u00f6r\u00fc MOD\u00dcL 6 - 89","\u2022 Fotovoltaik G\u00fc\u00e7 Sisteminde yer alan sens\u00f6rler verileri (\u0131\u015f\u0131n\u0131m, r\u00fczgar h\u0131z\u0131 ve y\u00f6n\u00fc, nem, ortam ve panel s\u0131cakl\u0131\u011f\u0131 vb.) okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Fotovoltaik G\u00fc\u00e7 Sistemlerinde yer alan dizilere ait DC ak\u0131m verileri okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Sistemde var ise DC Toplama panosuna dair dijital sinyaller okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Sistemde var ise AC saha toplama panosu ile Ana Al\u00e7ak Gerilim Panosunda yer alan TM\u015e sigorta gruplar\u0131na dair dijital sinyaller okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Sistemde var ise Redres\u00f6r, UPS, Yang\u0131n Alg\u0131lama Sens\u00f6rleri vb. cihazlara ait durum bilgilerine dair sinyaller okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Otomatik Alarm olu\u015fturma ve bilgi verme yap\u0131s\u0131na sahip olmal\u0131 \u2022 Kontrol ve Otomasyon sistemine dair altyap\u0131ya sahip olmal\u0131 \u2022 Y\u00fcksek Gerilim \u00f6l\u00e7\u00fcm verilerine (gerilim-ak\u0131m-frekans) dair sinyaller okunabilir ve g\u00f6sterilebilir olmal\u0131 \u2022 Esnek ve Geli\u015ftirilebilir Web\/Mobil Ara y\u00fcz altyap\u0131s\u0131na sahip olmal\u0131 Fotovoltaik G\u00fc\u00e7 Sistemlerine dair \u0130zleme Sistemi Web Aray\u00fcz \u00d6rnekleri \u015eekil 138-\u015eekil 142\u2019de verilmektedir. \u015eekil 138. Fotovoltaik G\u00fc\u00e7 Sistemi \u0130zleme Web Aray\u00fcz Sistemi \u00d6rne\u011fi-I \u015eekil 139. Fotovoltaik G\u00fc\u00e7 Sistemi \u0130zleme Web Aray\u00fcz Sistemi \u00d6rne\u011fi-II MOD\u00dcL 6 - 90","\u015eekil 140. Fotovoltaik G\u00fc\u00e7 Sistemi \u0130zleme Web Aray\u00fcz Sistemi \u00d6rne\u011fi-III \u015eekil 141. Fotovoltaik G\u00fc\u00e7 Sistemi \u0130zleme Web Aray\u00fcz Sistemi \u00d6rne\u011fi-IV \u015eekil 142. Fotovoltaik G\u00fc\u00e7 Sistemi \u0130zleme Web Aray\u00fcz Sistemi \u00d6rne\u011fi-V MOD\u00dcL 6 - 91","8.2. HABERLE\u015eME S\u0130STEMLER\u0130NDE ARIZA \u00c7E\u015e\u0130TLER\u0130 VE BAKIM- ONARIM Haberle\u015fme sistemlerinde olu\u015fan ar\u0131zalar\u0131n ba\u015fl\u0131calar\u0131; \u2022 Veri kaydedicisinin ileti\u015fim ar\u0131zas\u0131 \u2022 Eviricilerin tamam\u0131ndan veya bir k\u0131sm\u0131ndan veri gelmemesi \u2022 Sens\u00f6r gruplar\u0131n\u0131n tamam\u0131ndan veya bir k\u0131sm\u0131ndan veri gelmemesi \u2022 Di\u011fer sinyal al\u0131nan noktalar\u0131n tamam\u0131ndan veya bir k\u0131sm\u0131ndan veri gelmemesi \u2022 Kablo ar\u0131zalar\u0131 \u2022 Kablo ba\u011flant\u0131 ar\u0131zalar\u0131 \u2022 \u0130nternet sa\u011flay\u0131c\u0131s\u0131 kaynakl\u0131 ar\u0131zalar \u2022 Fiber \u2013 Ethernet d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc gibi d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc cihazlar\u0131ndan kaynaklanan ar\u0131zalar \u2022 Sistem konfig\u00fcrasyonu veya server kaynakl\u0131 ar\u0131zalar \u2022 RTU & MCU kaynakl\u0131 ar\u0131zalar \u015feklindedir. Haberle\u015fme sistemlerinde ya\u015fanan ar\u0131zalarda kar\u015f\u0131la\u015f\u0131lan durumlar \u00f6nce analiz edilmeli ve ar\u0131za noktas\u0131 t\u00fcmden gelim y\u00f6ntemi ile \u00e7\u00f6z\u00fcmlenmelidir. a) Eviricilerin tamam\u0131ndan veya bir k\u0131sm\u0131ndan veri gelmemesi \u00d6rne\u011fin, 10 adet eviricinin oldu\u011fu bir sistemde sadece 1 adet eviricinin haberle\u015fme ar\u0131zas\u0131na sahip oldu\u011fu ancak di\u011fer t\u00fcm sinyal noktalar\u0131ndan veri geldi\u011fi bir durumda, ar\u0131zan\u0131n odak noktas\u0131 evirici ve eviricinin ba\u011flant\u0131 hatt\u0131 ile ilgilidir. Ba\u015fka bir \u00f6rnekte, yine t\u00fcm eviricilerden haberle\u015fme al\u0131namamas\u0131 ancak sens\u00f6r ve di\u011fer sinyal gruplar\u0131ndan veri gelmesi durumunda; \u2022 Eviricilerin \u00e7al\u0131\u015f\u0131rl\u0131k kontrol\u00fc yap\u0131lmal\u0131d\u0131r. \u2022 Eviricilerden RTU veya Veri kaydedici cihazlar\u0131na giden haberle\u015fme hatt\u0131 son noktadan itibaren kontrol edilmelidir. \u2022 Switch veya D\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc (fiber-ethernet, fiber-rs) cihazlar\u0131n\u0131n i\u015flevsellik kontrolleri yap\u0131lmal\u0131d\u0131r. \u2022 Haberle\u015fme sistemlerinde \u00f6zellikle RJ45 pimleri ile yap\u0131lan evirici ba\u011flant\u0131larda, genel hata bu pimlerden kaynakl\u0131 olarak ortaya \u00e7\u0131kmaktad\u0131r. RJ45 pimlerden olu\u015fan bir haberle\u015fme hatt\u0131n\u0131n kablo sinyal testlerinin yap\u0131lmas\u0131, ar\u0131zay\u0131 indirgemeye yard\u0131mc\u0131 olacakt\u0131r. b) Sens\u00f6r gruplar\u0131n\u0131n tamam\u0131ndan veya bir k\u0131sm\u0131ndan veri gelmemesi \u015eekil 143\u2019de RS485 ileti\u015fim hatt\u0131 ile ba\u011flanan bir evirici-sens\u00f6r haberle\u015fme topolojisi g\u00f6sterilmektedir. \u015eekil 143. RS485 ileti\u015fim hatt\u0131 ile ba\u011flanan bir evirici-sens\u00f6r haberle\u015fme topolojisi MOD\u00dcL 6 - 92","\u015eekil 143\u2019de g\u00f6sterildi\u011fi gibi 2 ayr\u0131 hat ile RS485 seri ba\u011flant\u0131dan olu\u015fan inverter gruplar\u0131ndan bir grubun haberle\u015fmemesi , o gruba ait ana haberle\u015fme hatt\u0131 ve sonras\u0131nda sorun olabilece\u011fi \u00fczerine \u00f6l\u00e7\u00fcm ve testler yap\u0131lmas\u0131 ar\u0131zan\u0131n k\u00f6k nedenini bulmak i\u00e7in ba\u015flang\u0131\u00e7 safhas\u0131 olacakt\u0131r. c) Kablo ba\u011flant\u0131 ar\u0131zalar\u0131 RJ45 JACK \u2013 Registered Jack 45 \u00fczerinde 8 adet metal ba\u011flant\u0131 noktas\u0131 bulunan ve cihazlar aras\u0131 haberle\u015fme protokollerinin ta\u015f\u0131nd\u0131\u011f\u0131 kablolar\u0131n u\u00e7lar\u0131na ba\u011flanan bir elemand\u0131r. Genellikle cat5-cat6-cat7 s\u0131n\u0131flar\u0131nda internet \u2013 cihaz haberle\u015fmelerin kullan\u0131lan kablolarda sonland\u0131rma eleman\u0131 olarka kullan\u0131lan RJ45 jacklar\u0131n kablo renklerine g\u00f6re pinlere giri\u015fler standartlara g\u00f6re yap\u0131l\u0131r. Bir kablonun u\u00e7 k\u0131sm\u0131ndaki RJ45 jack pinlerine s\u0131rayla girilen renk kodlu kablo telleri ne ise, di\u011fer u\u00e7ta yer alan kablo sonland\u0131rmas\u0131 ayn\u0131 \u015fekilde ta\u015f\u0131n\u0131r. Aksi halde sinyallerin ta\u015f\u0131n\u0131m\u0131nda sorunlar ya\u015fanacakt\u0131r. Standartlara g\u00f6re kablo sonland\u0131rma kodlar\u0131 \u015eekil 144\u2019te g\u00f6sterilmektedir. \u015eekil 143. Standartlara g\u00f6re sonland\u0131rma kodlar\u0131 \u0130ki ucu RJ45 \/ RJ11 ile sonland\u0131r\u0131lm\u0131\u015f bir kablonun u\u00e7tan uca telleri aras\u0131nda sinyal aktar\u0131m\u0131 yap\u0131p yapmad\u0131\u011f\u0131, RJ konekt\u00f6r pimlerinin sa\u011fl\u0131kl\u0131 bir \u015fekilde yerine oturup oturmad\u0131\u011f\u0131 bir test cihaz\u0131yla \u00f6l\u00e7\u00fcmlenebilir (\u015eekil 144). \u0130\u015flem a\u015famalar\u0131: \u2022 Kablonun bir ucunu master cihaz\u0131n uygun b\u00f6l\u00fcm\u00fcne, di\u011fer ucunu remote cihaz\u0131n uygun b\u00f6l\u00fcm\u00fcne yerle\u015ftirin. \u2022 Test d\u00fc\u011fmesine bas\u0131n ya da testin ba\u015flamas\u0131 i\u00e7in biraz bekleyin. \u2022 1\u2019den 8\u2019e kadar LED\u2019lerin yan\u0131p yanmad\u0131\u011f\u0131n\u0131 g\u00f6zlemleyin. \u2022 Kar\u015f\u0131l\u0131kl\u0131 yanmayan LED olmas\u0131 durumunda ilgili hatt\u0131n RJ45 taraf\u0131ndaki pim yuvas\u0131nda olup olmad\u0131\u011f\u0131n\u0131, pim ile temas\u0131n\u0131n olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. \u2022 T\u00fcm kar\u015f\u0131l\u0131kl\u0131 LED\u2019lerin yanmas\u0131 halinde test ba\u015far\u0131yla ger\u00e7ekle\u015fmi\u015f ve sorunsuz bir sonland\u0131rma sa\u011flanm\u0131\u015ft\u0131r. Ar\u0131zal\u0131 bir RJ45 konekt\u00f6r\u00fc tespit edildi\u011finde, yenisi tak\u0131larak ve testi yap\u0131larak ar\u0131za \u00e7\u00f6z\u00fcmlenebilir. \u015eekil 144. RJ konekt\u00f6r pimlerini kontrol eden test cihaz\u0131 MOD\u00dcL 6 - 93","RJ45 konekt\u00f6r basma ad\u0131mlar\u0131 Tablo 10\u2019da verilmektedir. Tablo 10. RJ45 konekt\u00f6r basma ad\u0131mlar\u0131 Kabloyu u\u00e7tan 25 mm geriye do\u011fru s\u0131y\u0131r\u0131n. Bunun i\u00e7in kablo s\u0131y\u0131r\u0131c\u0131 veya bir pense \/ yankeski kullanabilirsiniz. Kablo tellerine zarar vermeyecek \u015fekilde, s\u0131y\u0131rma aletinin b\u0131\u00e7aklar\u0131 aras\u0131nda d\u0131\u015f kablo k\u0131l\u0131f\u0131n\u0131 hafif\u00e7e d\u00f6ndererek, kablo k\u0131l\u0131f\u0131n\u0131 kesip alabilirsiniz. Kablonun i\u00e7erisindeki telleri d\u00fczeltiniz Sonland\u0131rma standart\u0131na g\u00f6re kablo renkleri s\u0131raya getiriniz. \u00d6rne\u011fin T568B standard\u0131na g\u00f6re Jack i\u00e7erisine gierecek kablo renk s\u0131ralamas\u0131 soldan sa\u011fa olmak \u00fczere: 1-Turuncu&Beyaz; 2\u2013 Turuncu; 3\u2013Ye\u015fil&Beyaz; 4-Mavi; 5-Mavi&Beyaz; 6-Ye\u015fil; 7-Kahverengi&Beyaz; 8-Kahverengidir Kablo tellerini renk s\u0131ralamas\u0131na g\u00f6re d\u00fczg\u00fcn bir \u015fekilde s\u0131ralad\u0131ktan sonra yakla\u015f\u0131k olarak yar\u0131s\u0131na yak\u0131n\u0131 u\u00e7 k\u0131s\u0131mlar\u0131 d\u00fcz bir \u00e7izgi olu\u015fturacak \u015fekilde kesme pensesi yard\u0131m\u0131yla kesiniz. (Yakla\u015f\u0131k 13mm). Kablolar\u0131n u\u00e7 k\u0131s\u0131mlar\u0131 d\u00fczg\u00fcn bir hat olu\u015fturmal\u0131 ve uzunluklar\u0131 birbirinden farkl\u0131 olmamal\u0131d\u0131r Kablo tellerini RJ-45 Jack i\u00e7erisine tak\u0131n\u0131z. RJ-45 konekt\u00f6r\u00fcn\u00fcn klips taraf\u0131 alta bakacak \u015fekilde ya da metal pimlerin \u00fcste bakacak \u015fekilde \u00e7eviriniz ve kablolar\u0131 soldan sa\u011fa standartta belirtilen renk kodlar\u0131na g\u00f6re s\u0131ranlanm\u0131\u015f ve u\u00e7lar\u0131 d\u00fczg\u00fcn bir hat olu\u015fturacak \u015fekilde kesilmi\u015f \u015fekliyle i\u00e7eri girdiriniz. K\u00fc\u00e7\u00fck tellerden herhangi biri b\u00fck\u00fcl\u00fcrse ya da ilgili pim yuvas\u0131na girmemi\u015fse, iki tel ayn\u0131 pim yuvas\u0131nda \u00fcst \u00fcste gelmi\u015fse, i\u015flemi tekrar yapman\u0131z gerekmektedir. Konekt\u00f6r\u00fcn metal pimleri kablo tellerini s\u0131k\u0131\u015ft\u0131rmadan \u00f6nce her biri oyu\u011fa oturmal\u0131 ve d\u00fczg\u00fcn olmal\u0131d\u0131r. Konekt\u00f6r\u00fc aletin pim s\u0131k\u0131\u015ft\u0131rma u\u00e7lar\u0131na gelecek \u015fekilde yerle\u015ftirin. MOD\u00dcL 6 - 94","Konekt\u00f6r\u00fc aletin pim s\u0131k\u0131\u015ft\u0131rma u\u00e7lar\u0131na gelecek \u015fekilde yerle\u015ftirin ve iki kez s\u0131k\u0131n. T\u00fcm pimlerin a\u015fa\u011f\u0131 bast\u0131r\u0131ld\u0131\u011f\u0131ndan emin olun. Konekt\u00f6r basma pensesi metal pimlerin kablolara temas\u0131 i\u00e7in a\u015fa\u011f\u0131 do\u011fru iter. Herhangi bir pim kabloya temas etmiyorsa veya pimi s\u0131karken hasar alm\u0131\u015fsa, i\u015flemi yeni bir konekt\u00f6r ile tekrarlay\u0131n\u0131z. Konekt\u00f6r ve pimlerin irtibat\u0131n\u0131 kontrol ediniz. Pimlerden herhangi birinin hasar al\u0131p almad\u0131\u011f\u0131n\u0131 kontrol ediniz. MOD\u00dcL 6 - 95","KONU 9 ENERJ\u0130 DEPOLAMALI S\u0130STEMLER\u0130N BAKIM VE ONARIMI 9.1. ENERJ\u0130 DEPOLAMALI S\u0130STEMLERDE ARIZA \u00c7E\u015e\u0130TLER\u0130 Fotovoltaik g\u00fc\u00e7 sistemlerinde olu\u015fan ar\u0131zalara ili\u015fkin genel \u00f6zellikle fotovoltaik panel, evirici, kablo hatlar\u0131, kablo ba\u011flant\u0131lar\u0131, koruma ve sigorta panolar\u0131, \u00f6l\u00e7\u00fc sistemleri, mekanik sistemler i\u00e7in \u00f6nceki konularda verilmi\u015fti. Depolamal\u0131 sistemlerde ise bunlar\u0131n d\u0131\u015f\u0131nda en \u00f6nemli sistem ekipman\u0131 olan batarya\/ak\u00fc gruplar\u0131na dair ar\u0131zalar ortaya \u00e7\u0131kmaktad\u0131r. Genel anlam\u0131yla bu sistemlerde ya\u015fanan ba\u015fl\u0131ca ar\u0131zalar: 9.1.1. Evirici Ekran\u0131n\u0131n Kapal\u0131 Olmas\u0131 \u015eebeke-ba\u011flant\u0131s\u0131z eviricilerin ekranlar\u0131 genellikle ak\u00fc grubu taraf\u0131ndan sa\u011flan\u0131r. Ekran\u0131n olmamas\u0131, Ak\u00fc-Batarya grubunun gerilimin yeterli olmamas\u0131 kaynakl\u0131d\u0131r. Ak\u00fc-batarya grubu fabrikadan yeni \u00e7\u0131kt\u0131\u011f\u0131nda, genellikle tam \u015farjl\u0131d\u0131r. Ancak uzun s\u00fcre kullan\u0131lmazsa yava\u015f yava\u015f bo\u015fal\u0131r (kendi kendine bo\u015falma). Bu durumda batarya grubunun \u015farj edilmesi gerekmekte ve belli bir de\u011ferin \u00fczerine \u00e7\u0131kmas\u0131 g\u00f6zlemlenmelidir. Di\u011fer bir durumda batarya grubu \u2013 evirici k\u0131sm\u0131ndaki kablo ba\u011flant\u0131lar\u0131 iyi yap\u0131lmam\u0131\u015fsa ak\u00fc-batarya grubu voltaj\u0131 yetersiz olacakt\u0131r. Ak\u00fc terminali ters ba\u011flanm\u0131\u015f olabilir. Genellikle Pil terminali pozitif ve negatif kutuplara sahiptir. Genel olarak, k\u0131rm\u0131z\u0131 pozitif kutba ve siyah negatif kutba ba\u011flan\u0131r. Son olarak sistemde DC anahtar var ise devresi a\u00e7\u0131k olabilir ya da anahtarda bir ar\u0131za durumu olabilir. Bu tip durumlarda batarya grubunun ba\u011flant\u0131lar\u0131n\u0131 kontrol ediniz. Ba\u011flant\u0131 pimlerinin yerine tam ve do\u011fru \u015fekilde oturdu\u011funa emin olunuz. DC anahtarlamay\u0131 kontrol ediniz ve devresinin kapal\u0131 oldu\u011funa emin olunuz. Batarya grubu \u00e7\u0131k\u0131\u015f gerilimini bir multimetre \/ avometre ile \u00f6l\u00e7\u00fcn\u00fcz ve toplam \u00e7\u0131k\u0131\u015f geriliminin batarya grubu ba\u011flant\u0131 \u015femas\u0131na g\u00f6re (paralel-seri) do\u011fru oldu\u011funu teyit ediniz. Sistemde batarya grubu \u00e7\u0131k\u0131\u015f gerilimi normalse, kablo ba\u011flant\u0131s\u0131 normalse ve anahtar da a\u00e7\u0131ksa, ancak evirici ekran\u0131nda hala g\u00f6r\u00fcnt\u00fc yoksa sorun evirici i\u00e7 k\u0131sm\u0131nda olabilir. Bu tip durumlarda evirici \u00fcreticisi ile ileti\u015fime ge\u00e7iniz. 9.1.2. Pil \u015earj Edilemiyor Ar\u0131zas\u0131 Muhtemel sebeplerin ba\u015f\u0131nda fotovoltaik sistem \u00e7\u0131k\u0131\u015f gerilimi yeterli de\u011fil, g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131 d\u00fc\u015f\u00fck olabilir veya giri\u015f gerilimi a\u015f\u0131r\u0131 y\u00fcksek olabilir. Di\u011fer sebepler ise fotovoltaik-\u015farj kontrol \u00fcnitesi aras\u0131nda ya da \u015farj kontrol \u00fcnitesi-batarya grubu aras\u0131ndaki DC kablo ba\u011flant\u0131s\u0131nda sorun olabilir. Ak\u00fc devresi kablolamas\u0131 iyi yap\u0131lmam\u0131\u015f olabilir. Batarya tamamen \u015farj olmu\u015f ve en y\u00fcksek voltaja ula\u015fm\u0131\u015f olabilir. Pil tam \u015farja ula\u015ft\u0131\u011f\u0131nda yeniden \u015farj edilemez. Ak\u00fc \u015farj kontrol \u00fcnitesi ar\u0131zal\u0131 olabilir. Muhtemel \u00e7\u00f6z\u00fcmler i\u00e7in DC anahtar\u0131, terminal blo\u011fu, kablo konekt\u00f6r\u00fc, fotovoltaik bile\u015fen, batarya grubunun vb.'nin g\u00f6zle kontrol ederek her \u015feyin normal olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Birden fazla bile\u015fen varsa, bunlar ayr\u0131 ayr\u0131 test edilmelidir. 9.1.3. Giri\u015f A\u015f\u0131r\u0131 Ak\u0131m\u0131 Sistem bile\u015fenlerinin uyum sorunu olabilir. \u015earj kontrol \u00fcnitesinin \u015farj ak\u0131m\u0131 ile batarya grubunun maksimum \u015farj ak\u0131m\u0131n\u0131n \u00fczerinde olabilir. Dizayn ve uyumluluklar\u0131n\u0131 kontrol ediniz. MOD\u00dcL 6 - 96","9.1.4. Giri\u015f A\u015f\u0131r\u0131 Voltaj\u0131 Bile\u015fen giri\u015f voltaj\u0131 \u00e7ok y\u00fcksekse, batarya grubunun voltaj\u0131n\u0131n kontrol edilmesi gerekir. Ger\u00e7ekten y\u00fcksekse bunun olas\u0131 nedeni paneldeki dizi say\u0131s\u0131n\u0131n \u00e7ok fazla olmas\u0131 ve dizi ba\u011flant\u0131 konfig\u00fcrasyonun g\u00f6zden ge\u00e7irilmesi gerekebilir. 9.1.5. A\u015f\u0131r\u0131 Y\u00fck-Geri Besleme-A\u015f\u0131r\u0131 Y\u00fck Ak\u0131m Talebi vb. Y\u00fck Kaynakl\u0131 Ar\u0131zalar Genellikle y\u00fck\u00fcn \u00e7e\u015fidine ve talep etti\u011fi g\u00fcce g\u00f6re ortaya \u00e7\u0131kan ve evirici grubunda ar\u0131za meydana getirebilen durumlar\u0131 i\u00e7ermektedir (Tablo 11). Tablo 11. Bir off-grid eviriciye ait muhtemel ar\u0131za durumlar\u0131-sebepleri-\u00e7\u00f6z\u00fcmleri MOD\u00dcL 6 - 97","Kaynak makinesinin a\u015f\u0131r\u0131 ak\u0131m y\u00fck talebi, asans\u00f6r, elektrik motoru uygulamalar\u0131 gibi ilk kalk\u0131\u015fta yol verme uygulamalar\u0131n\u0131n yap\u0131lmas\u0131 gereklili\u011fi gibi y\u00fck \u00e7e\u015fitlerinin g\u00fc\u00e7 talep karakteristiklerine g\u00f6re y\u00fck taraf\u0131nda koruyucu ve dengeli y\u00fck talebi uygulamalar\u0131n\u0131n yap\u0131lmas\u0131 gereklidir. \u015eebekeden ba\u011f\u0131ms\u0131z g\u00fc\u00e7 sa\u011flay\u0131c\u0131 eviricilerin direkt olarak bu tip y\u00fckleri beslemesi durumunda a\u015f\u0131r\u0131 ak\u0131m uyar\u0131, k\u0131sa devre durumlar\u0131 veya geri besleme sebebiyle ar\u0131za durumlar\u0131 ortaya \u00e7\u0131kmaktad\u0131r. \u00c7\u00f6z\u00fcm olarak, y\u00fcklerin devrede oldu\u011fu zaman yek\u00fbn anma g\u00fcc\u00fc, evirici kurulu elektrik g\u00fcc\u00fcnden d\u00fc\u015f\u00fck olmal\u0131d\u0131r ve y\u00fck\u00fcn yek\u00fbn tepe g\u00fcc\u00fc, eviricinin anma g\u00fcc\u00fcn\u00fcn 1,5 kat\u0131ndan fazla olmamas\u0131na \u00f6zen g\u00f6sterilerek, y\u00fck ba\u011flant\u0131lar\u0131 yap\u0131lmal\u0131d\u0131r. 9.2. ENERJ\u0130 DEPOLAMALI S\u0130STEMLERDE BAKIM VE ONARIM 9.2.1. Batarya Grubu Gerilim Kontrol\u00fc Batarya-Ak\u00fc gruplar\u0131n\u0131n gerilim seviyelerinde d\u00fc\u015f\u00fckl\u00fck olup olmad\u0131\u011f\u0131n\u0131n kontrolleri yap\u0131lmal\u0131d\u0131r (\u015eekil 145). \u015eekil 145. Ak\u00fc Gerilim \u00d6l\u00e7\u00fcm\u00fc 9.2.2. Ba\u011flant\u0131 Kontrolleri- G\u00f6zle Kontrol Batarya-Ak\u00fc gruplar\u0131n\u0131n periyodik olarak ba\u011flant\u0131 noktalar\u0131n\u0131n kontrollerinin yap\u0131lmas\u0131 \u00f6nemlidir. Nem-S\u0131v\u0131 temas\u0131 ile k\u0131sa devre, a\u015f\u0131r\u0131 gerilim gibi durumlar sebebiyle ba\u011flant\u0131 hatlar\u0131nda ve ba\u011flant\u0131 noktalar\u0131nda hasar olu\u015fmas\u0131na kar\u015f\u0131n erken te\u015fhis \u00f6nemlidir. Ak\u00fc ba\u011flant\u0131lar\u0131nda oksitlenme \u00f6rnekleri \u015eekil 146\u2019de g\u00f6sterilmektedir. Ak\u00fc depolama sistemleri i\u00e7in, biri bak\u0131m i\u00e7in hizmet d\u0131\u015f\u0131 b\u0131rak\u0131labilirken di\u011fer dizi devam eden i\u015flemler i\u00e7in en az\u0131ndan bir miktar depolama sa\u011flayacak \u015fekilde iki paralel ak\u00fc dizisi tavsiye edilir. Bir pil tesisinin tasar\u0131m\u0131, servis i\u00e7in her bir h\u00fccreye kolay eri\u015fimi ve t\u00fcm pil tesisini s\u00f6kmeden tek tek birimlerin de\u011fi\u015ftirilmesini dikkate almal\u0131d\u0131r. MOD\u00dcL 6 - 98","\u015eekil 146. Ak\u00fc Ba\u011flant\u0131lar\u0131nda Oksitlenme 9.2.3. Havaland\u0131rma Kontrolleri Batarya Gruplar\u0131 tipik olarak bir muhafaza i\u00e7inde olacak olsa da bulundu\u011fu yer itibariyle \u00e7evresel ko\u015fullardan hala etkilenebilir (\u015eekil 147). \u00d6rne\u011fin, bir\u00e7ok pil, optimum performans i\u00e7in \u00f6nerilen s\u0131cakl\u0131k aral\u0131klar\u0131na sahiptir ve pillerin bu ayarlanan aral\u0131klar\u0131n d\u0131\u015f\u0131nda \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131, kapasitenin d\u00fc\u015fmesine, daha k\u0131sa pil kullan\u0131m \u00f6mr\u00fcne ve muhtemelen \u00fcr\u00fcn garantilerinin ge\u00e7ersiz olmas\u0131na neden olabilir, bu nedenle ortam s\u0131cakl\u0131klar\u0131 genellikle \u015fartland\u0131r\u0131lm\u0131\u015f muhafazalarda bile bak\u0131m uygulamalar\u0131n\u0131n gereksinimini ortaya koymaktad\u0131r. Pil \u00fcreticileri, pil muhafazas\u0131nda muhafaza edilmesi gereken s\u0131cakl\u0131k ve nem seviyelerini belirlemektedir. Ek olarak, eviricilerde do\u011fal so\u011futma sirk\u00fclasyonunun sa\u011flanmas\u0131 gereklili\u011finde oldu\u011fu gibi, ak\u00fc gruplar\u0131n\u0131n havaland\u0131rma sirk\u00fclasyonunu etkileyecek fakt\u00f6rlerin kontrolleri her zaman sa\u011flanmal\u0131 ve temiz tutulmal\u0131d\u0131r. Havaland\u0131rma delikleri, pilleri so\u011futmak ve belirli pil t\u00fcrleri i\u00e7in gazlar\u0131 havaland\u0131rmak i\u00e7in \u00f6nemli olacakt\u0131r (yani, belirli kur\u015fun asitli pil teknolojilerinde hidrojen gaz\u0131 \u00e7\u0131k\u0131\u015f\u0131 gibi). Pillerin ayr\u0131ca, belirli bir y\u00fcksekli\u011fin \u00fczerinde de\u011fer kayb\u0131 (veya belirli bir y\u00fcksekli\u011fin \u00fczerinde \u00fcr\u00fcn garantilerini ge\u00e7ersiz k\u0131lma) ve sismik derecelendirmelerle ili\u015fkili g\u00fcvenlik mekanizmalar\u0131 gibi \u00f6zel gereksinimleri ve h\u00fck\u00fcmleri olabilir. Konumland\u0131r\u0131ld\u0131klar\u0131 kabin vb. gere\u00e7lerin deprem gibi sars\u0131nt\u0131 olabilecek durumlara kar\u015f\u0131n korunakl\u0131 olmas\u0131 \u00f6nem arz etmektedir. \u015eekil 147. Ak\u00fc Kabininde Hasar MOD\u00dcL 6 - 99","9.2.4. De\u015farj-\u015earj Testi \/ \u0130\u00e7 Empedans Testi Piller zamanla de\u015farj-\u015farj d\u00f6ng\u00fcs\u00fcn\u00fcn etkisiyle kapasite ve verimlili\u011fini kaybeder. Kur\u015fun asitli ak\u00fcler i\u00e7in, d\u00fc\u015f\u00fck \u015farj durumunda ge\u00e7irilen s\u00fcre, reaksiyonun geri d\u00f6nd\u00fcr\u00fclemez hale gelmesine ve ak\u00fcn\u00fcn hasar g\u00f6rmesine neden olur. Kur\u015fun-asit piller i\u00e7in 1.000 veya 2.000 d\u00f6ng\u00fcl\u00fc \u00f6m\u00fcrler tipiktir ve Lityum-iyon sistemlerinde ara\u015ft\u0131rmalar 10.000 d\u00f6ng\u00fcye ula\u015fmas\u0131 y\u00f6n\u00fcnde devam etmektedir. Bataryalar daha tak\u0131lmadan \u00f6nce kapasitede kademeli bir azalma olur ve kullan\u0131ld\u0131k\u00e7a artar. Dolay\u0131s\u0131yla \u201c\u00f6m\u00fcr boyu\u201d, pilin ne zaman de\u011fi\u015ftirilmesi gerekti\u011fine dair baz\u0131 kriterleri ifade edebilmektedir. G\u00fcvenilirli\u011fin \u00f6nemli oldu\u011fu uygulamalar i\u00e7in, kapasitesi 1.000 d\u00f6ng\u00fcden sonra %80'e d\u00fc\u015fen bir h\u00fccrenin de\u011fi\u015ftirilmesi muhtemelen planlanacakt\u0131r, ancak bir\u00e7ok uygulamada pil, etkin kapasitesinin %60'a d\u00fc\u015fece\u011fi belki 2.000 d\u00f6ng\u00fcye kadar \u00e7al\u0131\u015fmaya devam edebilir. Bir pilin ger\u00e7ek kapasitesi bir \u015farj\/de\u015farj testi ile \u00f6l\u00e7\u00fclebilir, ancak bunun i\u00e7in test s\u00fcresi boyunca pilin \u00e7al\u0131\u015fmas\u0131na ara verilmesi gerekir. D\u00f6ng\u00fc \u00f6mr\u00fcn\u00fcn alternatif bir \u00f6l\u00e7\u00fcs\u00fc, h\u00fccrenin i\u00e7 direncine\/empedans\u0131na dayan\u0131r. Bu durumda d\u00f6ng\u00fc \u00f6mr\u00fc, pilin i\u00e7 direnci belirli bir miktarda, \u00f6rne\u011fin ba\u015flang\u0131\u00e7 de\u011ferinin 1,3 kat\u0131 kadar artmadan \u00f6nce ger\u00e7ekle\u015ftirebilece\u011fi d\u00f6ng\u00fc say\u0131s\u0131 olarak tan\u0131mlan\u0131r. De\u015farj-\u015earj verimlilik ve i\u00e7 empedans testleri uzman test merkezlerince yap\u0131lmas\u0131 \u00f6nerilmektedir. Periyodik bak\u0131m kontrollerinin bir par\u00e7as\u0131 de\u011fildir. 9.2.5. Termal Kontrol K\u0131z\u0131l\u00f6tesi g\u00f6r\u00fcnt\u00fclemenin FV dizilerinde, birle\u015ftirici kutularda ve anahtarlama tertibat\u0131ndaki tespit problemlerinde kullan\u0131m\u0131na benzer \u015fekilde, k\u0131z\u0131l\u00f6tesi g\u00f6r\u00fcnt\u00fcleme batarya sistemlerindeki sorunlar\u0131n yerini ve etkilerini ortaya \u00e7\u0131karabilir. Y\u00fcksek i\u00e7 dirence sahip bireysel pil h\u00fccreleri, kom\u015fu h\u00fccrelerden daha s\u0131cak g\u00f6r\u00fcn\u00fcr, gev\u015fek veya a\u015f\u0131nm\u0131\u015f pil direk ba\u011flant\u0131lar\u0131 daha s\u0131cak g\u00f6r\u00fcn\u00fcr ve diziler aras\u0131ndaki ak\u0131m dengesizli\u011fi s\u0131cakl\u0131k fark\u0131ndan g\u00f6r\u00fclebilir. Ak\u0131m\u0131 hi\u00e7 ge\u00e7meyen piller daha so\u011fuk g\u00f6r\u00fcn\u00fcr. \u015eekil 148\u2019te Ak\u00fc Termal Kontrol sonucuna ait bir \u00f6rnek payla\u015f\u0131lm\u0131\u015ft\u0131r. \u015eekil 148. Ak\u00fc Termal Kontrol MOD\u00dcL 6 - 100","KONU 10 TOPRAKLAMA ELEMANLARININ BAKIM VE ONARIMI Topraklama Sistemlerinde kullan\u0131lan ba\u015fl\u0131ca tan\u0131mla ve terimler: Toprak: Elektrik potansiyelinin her noktada s\u0131f\u0131r oldu\u011fu yery\u00fcz\u00fcn\u00fcn madde ve yer olarak ifadesidir. Topraklama iletkeni: Topraklanacak bir cihaz\u0131 ya da tesis b\u00f6l\u00fcm\u00fcn\u00fc, bir topraklay\u0131c\u0131ya ba\u011flayan topra\u011f\u0131n d\u0131\u015f\u0131nda veya yal\u0131t\u0131lm\u0131\u015f olarak topra\u011f\u0131n i\u00e7inde d\u00f6\u015fenmi\u015f bir iletkendir. Topraklama baras\u0131 (topraklama birle\u015ftirme iletkeni): Birden fazla topraklama iletkeninin ba\u011fland\u0131\u011f\u0131 bir topraklama iletkenidir. Topraklamak: Elektriksel bak\u0131mdan iletken bir par\u00e7ay\u0131 bir topraklama tesisi \u00fczerinden topra\u011fa ba\u011flamakt\u0131r. Topraklama: Topraklamak i\u00e7in kullan\u0131lan ara\u00e7, d\u00fczen ve y\u00f6ntemlerin t\u00fcm\u00fcd\u00fcr. 10.1. TOPRAKLAMA S\u0130STEMLER\u0130NDE OLU\u015eAN ARIZALAR Topraklama sistemlerinde olu\u015fan ar\u0131zalar\u0131n ba\u015fl\u0131calar\u0131: \u2022 Topraklama Sistemlerinde bir veya birden fazla hatt\u0131n kopuk olmas\u0131 ve e\u015f potansiyel devreyi zay\u0131flatmas\u0131 \u2022 Topraklama ba\u011flant\u0131 noktalar\u0131nda pas korozyon vb. durumlar \u2022 Topraklama kablolar\u0131n\u0131n ve kesitlerinin yanl\u0131\u015f se\u00e7ilmesi \u2022 Topraklama kablolar\u0131nda deformasyonlar \u2022 Topraklama e\u015f potansiyel bara k\u0131sm\u0131nda pas korozyon vb. durumlar \u2022 \u0130\u015f\u00e7ilik Hatalar\u0131 \u2022 Yanl\u0131\u015f ba\u011flant\u0131 eleman\u0131, kablo kesiti se\u00e7imi \u2022 Dizayn hatalar\u0131 \u2022 D\u0131\u015f fakt\u00f6rler (Y\u0131ld\u0131r\u0131m, F\u0131rt\u0131na, Deprem, yang\u0131n, Vandalizm, vb. Topraklama sistemlerinde g\u00f6r\u00fclen baz\u0131 ar\u0131za durumlar\u0131na y\u00f6nelik \u00f6rnekler \u015eekil 149-151\u2019da g\u00f6sterilmektedir. \u015eekil 149. Topraklama ve faz kablolar\u0131nda hasar olu\u015fmas\u0131 MOD\u00dcL 6 - 101","\u015eekil 150. Paslanma ve korozyon etkisi ile i\u015f\u00e7ilik hatalar\u0131 (yal\u0131t\u0131ml\u0131 plaka \u00fczerinde montaj) \u015eekil 151. Montaj hatalar\u0131 ile yanl\u0131\u015f \u00fcr\u00fcn kullan\u0131m\u0131 10.2. TOPRAKLAMA S\u0130STEMLER\u0130N\u0130N BAKIM ONARIMI Fotovoltaik G\u00fc\u00e7 Sistemleri i\u00e7erisinde yer alan topraklama sistemlerinin bak\u0131m ve onar\u0131m\u0131nda periyodik olarak yap\u0131lmas\u0131 gereken kontroller a\u015fa\u011f\u0131daki gibidir. 10.2.1. G\u00f6zle Kontrol T\u00fcm topraklama sistem hatt\u0131nda yer alan iletkenlerin, ba\u011flant\u0131 noktalar\u0131n\u0131n, ba\u011flant\u0131 baralar\u0131n\u0131n deformasyon ve s\u00fcreklili\u011fe kar\u015f\u0131n g\u00f6zle kontrol edilmesi gerekmektedir. \u2022 Fotovoltaik panellerin topraklama sistemi ile irtibat\u0131n\u0131n kontrol\u00fc \u2022 Eviricilerin g\u00f6vde topraklama iletkenlerinin ve ba\u011flant\u0131lar\u0131n\u0131n kontrol\u00fc \u2022 Al\u00e7ak Gerilim Panolarda topraklama ba\u011flant\u0131lar\u0131n\u0131n kontrol\u00fc \u2022 Toprak iletkenlerinin birle\u015fti\u011fi, topraklama bara noktalar\u0131n\u0131n kontrol\u00fc \u2022 Fotovoltaik panel ta\u015f\u0131y\u0131c\u0131 sistemlerinin topraklama iletkenleri ile irtibat\u0131n\u0131n kontrol\u00fc \u2022 E\u015f-potansiyel baradaki t\u00fcm topraklama irtibat\u0131n\u0131n kontrol\u00fc MOD\u00dcL 6 - 102","10.2.2. Ba\u011flant\u0131 kontrolleri Topraklama iletkenlerinin ba\u011flant\u0131 noktalar\u0131nda s\u0131k\u0131l\u0131k \u2013 gev\u015feklik kontrolleri yap\u0131lmal\u0131d\u0131r. Yer Tipi Fotovoltaik G\u00fc\u00e7 Sistemlerinde e\u015f-potansiyellik yaratmak amac\u0131yla masalar aras\u0131nda, topraklama iletkenleri ile topraklama altyap\u0131s\u0131nda s\u00fcreklilik sa\u011flayan topraklama sistemi olu\u015fturulur. Kontrollerinde bu ara ba\u011flant\u0131lar\u0131n kontrol edilmesi gerekmektedir. \u015eekil 152\u2019de masalar aras\u0131 topraklama ba\u011flant\u0131s\u0131 g\u00f6sterilmektedir. \u015eekil 152. Masalar Aras\u0131 Topraklama Ba\u011flant\u0131s\u0131 Masalar aras\u0131ndaki topraklama ba\u011flant\u0131lar\u0131, masa sonunda veya ba\u015f\u0131nda, e\u015f potansiyel alana eklenerek birle\u015ftirilir. Yan yana devam eden masa yerle\u015fimleri d\u00e2hil olmak \u00fczere arka arkaya s\u0131ral\u0131 giden t\u00fcm masalarda farkl\u0131 uygulamalar ile e\u015f-potansiyel alan yarat\u0131lmak \u00fczere ba\u011flant\u0131lar farkl\u0131 \u015fekilde yap\u0131labilir. Bu noktada Masa ta\u015f\u0131y\u0131c\u0131 profillerin aras\u0131nda (a\u015f\u0131klar aras\u0131) yap\u0131lan d\u0131\u015f ortama a\u00e7\u0131k ba\u011flant\u0131lar\u0131n yans\u0131ra, masa ta\u015f\u0131y\u0131c\u0131 ayaklar\u0131n (Kolon) aras\u0131nda toprak alt\u0131ndan yap\u0131lan uygulamalarda vard\u0131r (\u015eekil 153). \u015eekil 153. Masa Ayaklar\u0131n\u0131n Topraklama Ba\u011flant\u0131s\u0131 MOD\u00dcL 6 - 103","\u015eekil 154\u2019da masa ayaklar\u0131 aras\u0131ndaki topraklama ba\u011flant\u0131s\u0131n\u0131n detaylar\u0131 g\u00f6sterilmektedir. \u015eekil 154. Masa Ayaklar\u0131 Aras\u0131nda Topraklama Ba\u011flant\u0131s\u0131 Masa a\u015f\u0131klar\u0131 aras\u0131ndaki toplama ba\u011flant\u0131s\u0131na ait g\u00f6rseller \u015eekil 155\u2019de payla\u015f\u0131lmaktad\u0131r. \u015eekil 155. Masa A\u015f\u0131klar\u0131 Aras\u0131nda Topraklama Ba\u011flant\u0131s\u0131 T\u00fcm topraklama ba\u011flant\u0131lar\u0131, bir noktada toplanarak ana topraklama bara hatt\u0131na getirilmesi ama\u00e7lanmaktad\u0131r (\u015eekil 156). \u015eekil 156. E\u015f Potansiyel Genel \u015eema MOD\u00dcL 6 - 104","Evirici \u2013Al\u00e7ak Gerilim Panolar\u0131n\u0131n g\u00f6vde k\u0131s\u0131mlar\u0131n\u0131n topraklama ba\u011flant\u0131lar\u0131n\u0131n periyodik olarak kontrol edilmesi gerekmektedir (\u015eekil 157). \u015eekil 157. Evirici G\u00f6vde Topraklama Ba\u011flant\u0131s\u0131 E\u015f potansiyel bara k\u0131s\u0131mlar\u0131na gelen topraklama hatlar\u0131n\u0131n ba\u011flant\u0131lar\u0131n\u0131n periyodik olarak kontrol edilmesi gerekmektedir (\u015eekil 158). \u015eekil 158. Topraklama Hatlar\u0131n\u0131n E\u015f Potansiyel Barada Birle\u015ftirilmesi MOD\u00dcL 6 - 105","10.2.3. Periyodik \u00d6l\u00e7\u00fcmler Topraklama sistemlerinde y\u0131lda en az 1 kez \u0130\u015fletme ve Koruma Topraklamalar\u0131n \u00d6l\u00e7\u00fclmesi ve uygun de\u011ferlerde oldu\u011funun tespiti yap\u0131lmal\u0131d\u0131r. Topraklama \u00f6l\u00e7\u00fcm\u00fcnde ba\u015fl\u0131ca \u00f6zg\u00fcl toprak direnci (toprak \u00f6zg\u00fcl direnci), topraklay\u0131c\u0131lar\u0131n yay\u0131lma direnci (RE) ve topraklama direnci \u00f6l\u00e7\u00fcmleri yap\u0131lmaktad\u0131r. a) \u00d6zg\u00fcl Toprak Direnci \u00d6zg\u00fcl toprak direnci 1 metre k\u00fcp topra\u011f\u0131n direnci olarak an\u0131lmaktad\u0131r. Bu diren\u00e7 de\u011feri, topra\u011f\u0131n i\u00e7inden ge\u00e7en elektrik ak\u0131m\u0131na kar\u015f\u0131 koyma, direnme ve azaltma kapasitesinin \u00f6l\u00e7\u00fcs\u00fcd\u00fcr. Bile\u015fim, nem i\u00e7eri\u011fi ve s\u0131cakl\u0131ktaki de\u011fi\u015fiklikler nedeniyle derinli\u011fi ve geni\u015fli\u011fi boyunca de\u011fi\u015fir. \u00d6zg\u00fcl Toprak Direnci veya Toprak \u00d6zg\u00fcl Direnci \u00f6l\u00e7\u00fcmleri i\u00e7in bir\u00e7ok farkl\u0131 metot olsa da bunlar i\u00e7erisinde yayg\u0131n olarak kullan\u0131lan WENNER y\u00f6ntemidir. Wenner \u00d6l\u00e7\u00fcm Y\u00f6ntemi genel \u015femas\u0131 \u015eekil 174\u2019te g\u00f6sterilmektedir. \u015eekil 159. Wenner \u00d6l\u00e7\u00fcm Y\u00f6ntemi Genel \u015eemas\u0131 Wenner 4 kaz\u0131kl\u0131 \u00f6l\u00e7\u00fcm y\u00f6ntemi, toprak \u00f6zdiren\u00e7 \u00f6l\u00e7\u00fcmleri i\u00e7in en yayg\u0131n kullan\u0131lan tekniktir. D\u00f6rt kaz\u0131\u011f\u0131n e\u015fit aral\u0131klarla yerle\u015ftirilmesi, en d\u0131\u015ftaki elektrotlara bilinen bir ak\u0131m enjekte edilmesi ve i\u00e7 elektrotlar aras\u0131ndaki voltaj\u0131n kaydedilmesi ile ger\u00e7ekle\u015ftirilir. Yukar\u0131daki \u015fekil, Wenner 4 kaz\u0131kl\u0131 \u00f6l\u00e7\u00fcm y\u00f6ntemi g\u00f6stermektedir. Sondan\u0131n derinli\u011fi, b <<a ise, zemine yaln\u0131zca k\u0131sa bir mesafe i\u00e7in giren elektrotla g\u00f6r\u00fcn\u00fcr \u00f6zdiren\u00e7 a\u015fa\u011f\u0131daki gibi hesaplanabilir. Genellikle elektrotlar\u0131n toprak i\u00e7erisindeki mesafesi, elektrotlar aras\u0131 mesafenin en az 1\/3 \u00fc kadar olmal\u0131d\u0131r. !\\\" = 2\u03c0a ' (2) I ! =R (3) \\\" B\u00f6ylece !\\\" = 2\u03c0aR (4) olarak hesaplanabilmektedir. \u00d6rne\u011fin, 2 metre derinlikteli toprak \u00f6zg\u00fcl direncini \u00f6l\u00e7mek i\u00e7in Wenner 4 Kaz\u0131kl\u0131 \u00f6l\u00e7\u00fcm y\u00f6ntemiyle, \u00f6l\u00e7\u00fcm yapan bir cihaz ile elektrotlar aras\u0131 mesafe e\u015fit bir \u015eekil 160\u2019da 6 metre olarak al\u0131nm\u0131\u015ft\u0131r. Ak\u0131m MOD\u00dcL 6 - 106","elektrotlar\u0131ndan ge\u00e7en ak\u0131m ile gerilim elektrotlar\u0131 aras\u0131 potansiyel fark ile R diren\u00e7 de\u011feri 50 ohm olarak \u00f6l\u00e7\u00fclm\u00fc\u015ft\u00fcr. Bu durumda 2 metre derinlikteki toprak \u00f6zg\u00fcl direnci: Pe=2x3,14x6x50 =1.884 Ohm x metre olarak bulunacakt\u0131r. \u015eekil 160. Wenner Y\u00f6ntemiyle \u00d6l\u00e7\u00fcmleme Toprak \u00f6zg\u00fcl direncin belirlenmesinde kullan\u0131lacak cihazlar\u0131n, kullan\u0131m k\u0131lavuzlar\u0131nda yer alan \u00f6l\u00e7\u00fcm ad\u0131mlar\u0131 ve y\u00f6nergeler dikkate al\u0131narak \u00f6l\u00e7\u00fcmler yap\u0131lmal\u0131d\u0131r. b) Topraklay\u0131c\u0131lar\u0131n yay\u0131lma direnci (RE) Yay\u0131lma direnci topraklay\u0131c\u0131n\u0131n \u015fekline, boyutlar\u0131na ve topra\u011f\u0131n \u00f6zg\u00fcl direncine ba\u011fl\u0131d\u0131r. Topraklay\u0131c\u0131 ile referans topra\u011f\u0131 aras\u0131ndaki topra\u011f\u0131n direncidir (\u015eekil 161) . Toprak yay\u0131lma direncinin hesaplanmas\u0131 i\u00e7in \u00e7e\u015fitli hesap y\u00f6ntemleri kullan\u0131lsa da bu y\u00f6ntemler en fazla iki d\u00fc\u015fey tabakal\u0131 b\u00f6lgelere kadar uygun sonu\u00e7lar vermektedir. \u015eekil 161. Topraklay\u0131c\u0131lar\u0131n Yay\u0131lma Direnci MOD\u00dcL 6 - 107","c) Topraklama direnci Bir topraklama tesisi ile referans toprak aras\u0131nda \u00f6l\u00e7\u00fclen diren\u00e7 de\u011feridir. Topraklama baras\u0131ndan ba\u015flayarak, toprak iletkeni ve baras\u0131n\u0131n diren\u00e7leri, toprak elektrotlar\u0131n\u0131n y\u00fczeyi ile toprak aras\u0131ndaki ge\u00e7i\u015f direnci ve topraklay\u0131c\u0131 yay\u0131lma direncinden olu\u015fur. Genellikle di\u011fer diren\u00e7lerin topra\u011f\u0131n yay\u0131lma direncine g\u00f6re \u00e7ok k\u00fc\u00e7\u00fck olmas\u0131 nedeniyle topraklama direncinin, topra\u011f\u0131n yay\u0131lma direncinden olu\u015ftu\u011fu kabul edilir. Topraklama elektrodunun uzunlu\u011fu\/derinli\u011fi, Topraklama elektrodunun \u00e7ap\u0131, Topraklama elektrodu say\u0131s\u0131, Topraklama sisteminin tasar\u0131m\u0131 gibi fakt\u00f6rlerden etkilenir. Topraklama direncinin azalt\u0131lmas\u0131n\u0131n etkin bir yolu topraklama elektrotlar\u0131n\u0131 daha derine yerle\u015ftirmektir. Topra\u011f\u0131n \u00f6zg\u00fcl direnci de\u011fi\u015fkendir ve direncin \u00f6ng\u00f6r\u00fclmesi zordur. Topraklama elektrodunun don seviyesinin \u00f6tesine yerle\u015ftirilmesi son derece \u00f6nemlidir. Bu uygulama, topraklama direncinin, \u00e7evreleyen topra\u011f\u0131n donmas\u0131ndan \u00f6nemli derecede etkilenmemesi i\u00e7in yap\u0131l\u0131r. Genellikle, topraklama elektrodunun uzunlu\u011funu iki kat\u0131na \u00e7\u0131kararak diren\u00e7 seviyesini %40 oran\u0131nda azalt\u0131labilir. Zeminin kaya, granit gibi yap\u0131lardan olu\u015ftu\u011fu durumlarda topraklama elektrodunun daha derine yerle\u015ftirilmesi fiziksel olarak m\u00fcmk\u00fcn olmayabilir. Bu durumlarda topraklama betonu gibi alternatif y\u00f6ntemler uygulanabilir. Topraklama elektrodunun \u00e7ap\u0131n\u0131n art\u0131r\u0131lmas\u0131, direncin azalt\u0131lmas\u0131n\u0131 d\u00fc\u015f\u00fck derecede etkiler. \u00d6rne\u011fin, topraklama elektrodunun \u00e7ap\u0131 iki kat\u0131na \u00e7\u0131kar\u0131ld\u0131\u011f\u0131nda diren\u00e7 sadece %10 oran\u0131nda azal\u0131r. Topraklama direncini azaltman\u0131n ba\u015fka bir yolu birden \u00e7ok topraklama elektrodu kullanmakt\u0131r. Bu tasar\u0131mda topra\u011fa birden \u00e7ok elektrot yerle\u015ftirilir ve direnci azaltmak i\u00e7in paralel bi\u00e7imde ba\u011flan\u0131r (\u015eekil 162). Ek elektrotlar\u0131n etkin olabilmesi i\u00e7in ek \u00e7ubuklar\u0131n aras\u0131ndaki mesafenin en az \u00e7ubu\u011fun derinli\u011fi kadar olmas\u0131 gerekir. Topraklama elektrotlar\u0131n\u0131n aras\u0131nda yetersiz mesafe oldu\u011funda, etki alanlar\u0131 kesi\u015fir ve diren\u00e7 azalmaz. \u015eekil 162. Birden Fazla Topraklama Elektrodu ile Yap\u0131lan Uygulama Topraklama Direnci \u00d6l\u00e7\u00fcm\u00fc: Genellikle 2 kaz\u0131kl\u0131 3 kablolu y\u00f6ntem kullan\u0131larak yap\u0131lan \u00f6l\u00e7\u00fcmlerde topraklama elektrodundan al\u0131nan referans ile toprak referans\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r ve topraklama elektrodunun direnci yani topraklama direnci \u00f6l\u00e7\u00fclm\u00fc\u015f olur (\u015eekil 163). MOD\u00dcL 6 - 108","\u015eekil 163. Topraklama Direnci \u00d6l\u00e7\u00fcm \u015eemas\u0131 \u00d6l\u00e7\u00fcm\u00fcn prensibi Ohm Kanunu\u2019na dayanmaktad\u0131r. Toprak referans noktas\u0131 ile C elektrodu aras\u0131nda \u00fcretilen ak\u0131m sayesinde P elektrodu ile toprak referans\u0131 aras\u0131ndaki potansiyel ortaya konarak R= V\/I form\u00fcl\u00fc cihaz \u00fczerinde hesaplanarak diren\u00e7 olarak g\u00f6sterilir (\u015eekil 164). \u015eekil 164. Topraklama \u00d6l\u00e7\u00fcm\u00fc Elektriksel Hesaplama Y\u00f6ntem \u015eemas\u0131 \u00d6l\u00e7\u00fcm i\u00e7in P ve C kaz\u0131klar\u0131 (elektrotlar) aras\u0131 mesafe \u00f6l\u00e7\u00fcm problar\u0131n\u0131n kablo uzunluklar\u0131na g\u00f6re ayarlanabilir ancak minimum 5 metre olmas\u0131 istenir. Ba\u011flant\u0131lar yap\u0131ld\u0131ktan sonra cihazda \u00f6l\u00e7\u00fcm kademesi ayarlan\u0131r ve \u00f6l\u00e7\u00fcm al\u0131n\u0131r. MOD\u00dcL 6 - 109","KONU 11 FOTOVOLTA\u0130K G\u00dc\u00c7 S\u0130STEM\u0130N\u0130N DEVREYE ALINMASI 11.1. \u00c7ALI\u015eMA KONTROL\u00dc Fotovoltaik G\u00fc\u00e7 Sistemlerinde bak\u0131m onar\u0131m \u00e7al\u0131\u015fmalar\u0131 ile devreden \u00e7\u0131karma ve devreye alma \u00e7al\u0131\u015fmalar\u0131nda a\u015fa\u011f\u0131daki talimatlar izlenmelidir. 11.1.1. Devreden \u00c7\u0131karma Evirici \/ Evirici Gruplar\u0131n\u0131n devreden \u00e7\u0131kar\u0131lmas\u0131 istenildi\u011finde; \u2022 Saha toplama panosu i\u00e7erisinde ve Al\u00e7ak Gerilim panosu i\u00e7erisinde bulunan eviriciye \/ eviricilere ait AG Koruma \u015falterlerini a\u00e7\u0131k konuma getiriniz. \u2022 Eviricilerin DC \u015falterlerini a\u00e7\u0131k konuma getiriniz. \u2022 Saha toplama panosu varsa ise i\u00e7erisinde bulunan STP Ana AG \u015falterlerini a\u00e7\u0131k konuma getiriniz. \u2022 Ana al\u00e7ak gerilim da\u011f\u0131t\u0131m panosunda saha toplama panosundan \/ panolar\u0131ndan gelen ve STP\u2019ye ait AG \u015falterleri a\u00e7\u0131k konuma getiriniz. \u2022 Belli bir evirici grubunu devreden \u00e7\u0131karmak i\u00e7in yukar\u0131daki ad\u0131mlar\u0131 s\u0131ras\u0131yla izleyiniz. \u2022 GES sahas\u0131n\u0131n tamam\u0131n\u0131n devreden \u00e7\u0131kar\u0131lmas\u0131 durumunda, Ana Al\u00e7ak Gerilim panosunun motorlu \/ motorsuz termik manyetik \u015falteri a\u00e7\u0131k konuma al\u0131n\u0131z. \u2022 T\u00fcm m\u00fcdahaleler esnas\u0131nda ISG talimatlar\u0131na uyunuz. \u2022 Y\u00fcksek gerilim taraf\u0131ndan enerjinin kesilmesi i\u00e7in \u0130\u015fletme Sorumlusuna ba\u015fvurunuz. 11.1.2. Devreye Alma Evirici \/ Evirici Gruplar\u0131n\u0131n devreye al\u0131nmas\u0131 istenildi\u011finde; \u2022 Evirici \/ Eviricilerin DC \u015ealterlerini kapal\u0131 konuma getiriniz. \u2022 Enerjinin ilk olarak kesildi\u011fi noktadan ba\u015flayarak evirici giri\u015f k\u0131sm\u0131na kadar AC beslemeleri koruma \u015falterinin devresini kapal\u0131 konuma getirerek devreye al\u0131n\u0131z. \u2022 E\u011fer Ana Giri\u015f panosunun \u00e7\u0131k\u0131\u015f k\u0131sm\u0131na kadar enerji verildiyse, AGP ana \u015falterine kapama veriniz. \u2022 AGP i\u00e7erisinde eviricilere veya saha toplama panolar\u0131na giden hatlar\u0131n beslemeleri, ilgili koruma \u015falterlerinin devresini kapal\u0131 konuma getirerek veriniz. \u2022 STP panosu var ise, i\u00e7erisindeki ana koruma sigortas\u0131n\u0131n devresini kapal\u0131 konuma getiriniz. \u2022 STP panosu i\u00e7erisinde eviricilere ait koruma sigortalar\u0131n\u0131n devresini kapal\u0131 konuma getirerek eviricilere AC besleme sa\u011flay\u0131n\u0131z. \u015eekil 165 ve \u015eekil 166\u2019da GES Projesi Tek Hat \u015eemas\u0131 \u00f6rnekleri sunulmaktad\u0131r. GES santrallerinde Evirici AC hatlar\u0131 direkt olarak ana giri\u015f panosuna (Ana toplama panosu) gidiyor ise AGP ile aras\u0131nda sadece eviriciye ait sigorta korumas\u0131 yer almaktad\u0131r. E\u011fer sahada eviricilerin belirli bir k\u0131sm\u0131n\u0131n AC besleme hatt\u0131n\u0131n topland\u0131\u011f\u0131 saha toplama panosu var ise AGP ile evirici aras\u0131nda evirici koruma \u015falteri, STP \u00e7\u0131k\u0131\u015f koruma \u015falteri, STP giri\u015f koruma \u015falteri olmak \u00fczere 3 koruma birimi olacakt\u0131r. MOD\u00dcL 6 - 110","\u015eekil 165. Bir GES Projesi Tek Hat \u015eemas\u0131-I \u015eekil 166. GES Projesi Tek Hat \u015eemas\u0131-II 11.2. M\u00dc\u015eTER\u0130 \u0130L\u0130\u015eK\u0130LER\u0130 VE \u0130LET\u0130\u015e\u0130M Bak\u0131m Onar\u0131m s\u00fcre\u00e7lerinde m\u00fc\u015fteri bilgilendirmeleri yaz\u0131l\u0131 ve s\u00f6zl\u00fc olarak mutlaka yap\u0131lmal\u0131d\u0131r. 11.2.1. Ar\u0131zaya M\u00fcdahale \u2013 D\u00fczenleyici Faaliyetler \u0130\u00e7in \u2022 Ar\u0131zaya m\u00fcdahale \u00f6ncesi durum \u2022 Ar\u0131zaya m\u00fcdahale \u00e7al\u0131\u015fmalar\u0131 \u2022 Ar\u0131zan\u0131n giderilmesi sonras\u0131 durum \u2022 Kullan\u0131lan malzeme ve yedek par\u00e7alar \u2022 Sorunun k\u00f6k sebebine ili\u015fkin yorumlar \u2022 Sorunun olu\u015fmamas\u0131 i\u00e7in al\u0131nmas\u0131 gereken \u00f6nlemlere ili\u015fkin \u00f6neriler \u2022 Yap\u0131lan test-\u00f6l\u00e7\u00fcm \u00e7\u0131kt\u0131lar\u0131 \u2022 Ar\u0131za tespit zaman\u0131 \u2022 Ar\u0131zaya m\u00fcdahale zaman\u0131 \u2022 Ar\u0131zan\u0131n sonlanmas\u0131na ili\u015fkin zaman Konu ba\u015fl\u0131klar\u0131n\u0131 i\u00e7eren g\u00f6rsel i\u00e7erikli bir rapor sunulmas\u0131 yap\u0131lan faaliyetlere ili\u015fkin \u00e7al\u0131\u015fman\u0131n \u00f6nemini ortaya koyacakt\u0131r. MOD\u00dcL 6 - 111","11.2.2. \u00d6nleyici Bak\u0131m Onar\u0131m Faaliyetleri \u0130\u00e7in Her bir kontrol noktas\u0131nda yap\u0131lan \u00f6l\u00e7\u00fcm-test-muayene-kontrol \u00e7al\u0131\u015fmalar\u0131n\u0131n ve kar\u015f\u0131la\u015f\u0131lan olumsuz durumlar i\u00e7in d\u00fczenleyici faaliyet \u00e7al\u0131\u015fmalar\u0131n\u0131n foto\u011frafl\u0131 detaylar\u0131 ile birlikte raporlanmas\u0131 \u00f6nemlidir. \u00d6nleyici ve D\u00fczenleyici Bak\u0131m Onar\u0131m \u00e7al\u0131\u015fmalar\u0131nda gerekli olabilecek ve sahada bulunmayan malzeme, ekipman, cihaz vb. ihtiya\u00e7lar\u0131n m\u00fc\u015fteriye sebepleri ile bildirilerek tedarikinin sa\u011flanmas\u0131 gerekmektedir. Santral yedek malzeme sto\u011funda bulunan malzemelerin belirli periyotlar ile kontrol edilmesi ve minimum miktar alt\u0131na d\u00fc\u015fen malzemelerin tedarikinin sa\u011flanmas\u0131 gerekmektedir. GES santrallerinde \u00fcretimi etkileyen ar\u0131zalar i\u00e7in kritik \u00f6neme sahip baz\u0131 malzemelerin stok olarak tutulmas\u0131 i\u00e7in M\u00fc\u015fteri ile koordinasyonun sa\u011flanmas\u0131 gerekmektedir. Garanti kapsam\u0131nda meydana gelen ar\u0131zalanan cihazlar i\u00e7in \u00fcretici firma ile ileti\u015fimin sa\u011flanmas\u0131 ve bunun her ad\u0131m\u0131nda m\u00fc\u015fteri bilgilendirmesinin yap\u0131lmas\u0131 \u00f6nem arz etmektedir. GES projesinde genel i\u015fleyi\u015f\/yap\u0131 \u015eekil 167\u2019de \u00f6zetlenmi\u015ftir. \u015eekil 167. GES Projesi Genel \u0130\u015fleyi\u015f MOD\u00dcL 6 - 112","KONU 12 UYGULAMA FAAL\u0130YETLER\u0130 Her bir mod\u00fcldeki uygulama faaliyetlerinin; \u00f6ncelikle Fotovoltaik G\u00fc\u00e7 Sistemleri Personeli (Seviye 5) Ulusal Yeterlili\u011fi Performansa Dayal\u0131 S\u0131nav ba\u015fl\u0131\u011f\u0131 alt\u0131nda belirlenmi\u015f \u201cBeceriler ve Yetkinlikler (BY)\u201d kontrol listesine g\u00f6re planlanmas\u0131 gerekti\u011fi dikkate al\u0131nmal\u0131d\u0131r. Beceri ve yetkinlikler kontrol listesinde aday taraf\u0131ndan ba\u015far\u0131lmas\u0131 zorunlu kritik ad\u0131mlar\u0131 i\u00e7erecek uygulamalara mutlaka yer verilmelidir. E\u011fer mevcut Mod\u00fcl i\u00e7eri\u011fine direkt hitap eden bir Yeterlilik Birimi yoksa (\u00f6rne\u011fin Mod\u00fcl 1 ve Mod\u00fcl 3) Yeterlilik Birimi i\u00e7in Performans S\u0131nav\u0131 uygulamas\u0131 yoksa (\u00f6rne\u011fin Mod\u00fcl 2), bu durumdaki uygulama faaliyetlerinin mesleki geli\u015fime katk\u0131 sa\u011flayacak \u015fekilde geli\u015ftirilmesi \u00f6nerilmektedir. Uygulamalar; e\u011fitimin verilece\u011fi \u00fcniversitelerin laboratuvar olanaklar\u0131 ve saha gezisi i\u00e7in elveri\u015fli tesislerin olanaklar\u0131 \u00e7er\u00e7evesinde geli\u015ftirilmelidir. \u00d6zellikle kapal\u0131 alan laboratuvar altyap\u0131s\u0131 g\u00fc\u00e7l\u00fc \u00fcniversiteler taraf\u0131ndan verilecek e\u011fitimlerde; ba\u015fta M\u00fchendis kat\u0131l\u0131mc\u0131lar olmak \u00fczere, t\u00fcm teknik bran\u015flardan kat\u0131l\u0131mc\u0131lar i\u00e7in \u2018Laboratuvar Uygulamalar\u0131 Rehberi\/F\u00f6y\u00fc\u2019 niteli\u011findeki ek bir materyalin haz\u0131rlanmas\u0131, e\u011fitimin meslekte geli\u015fim ve rekabet\u00e7ilik y\u00f6n\u00fcyle \u00f6ne \u00e7\u0131kmas\u0131na katk\u0131 sa\u011flayabilecektir. Mod\u00fcl 6 \u0130\u00e7in \u00d6rnek Uygulama Faaliyetleri Listesi: BY.1 Bak\u0131m i\u00e7in gerekli olan ekipmanlar\u0131 haz\u0131rlar. BY.2 Bak\u0131m yapaca\u011f\u0131 alan\u0131n enerjisinin kesilmesi i\u00e7in ilgili birime bilgi verir. BY.3 Bak\u0131m yapaca\u011f\u0131 alan\u0131n enerjisinin kesilip kesilmedi\u011fini kontrol eder. BY.4 Bak\u0131m yapaca\u011f\u0131 alan\u0131n enerjisinin kesilmesiyle ilgili kontrol sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 aksakl\u0131klar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. BY.5 Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinin g\u00f6rsel kontrollerini (izolasyon, gev\u015feklik, a\u015f\u0131nma, oksitlenme, s\u0131zd\u0131rmazl\u0131k ve benzeri) yapar. BY.6 Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinin g\u00f6rsel kontrol sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 aksakl\u0131klar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. BY.7 Bak\u0131m kapsam\u0131nda elektrik sisteminde \u00f6l\u00e7\u00fcmlerin yap\u0131laca\u011f\u0131 noktalar\u0131 belirler. BY.8 Belirledi\u011fi \u00f6l\u00e7\u00fcm noktalar\u0131nda dizilerin a\u00e7\u0131k devre gerilim de\u011ferini \u00f6l\u00e7er. BY.9 Elektrik sisteminin \u00f6l\u00e7\u00fcm sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 aksakl\u0131klar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. BY.17 Bak\u0131m yapt\u0131\u011f\u0131 alana enerji verilmesi i\u00e7in ilgili birime bilgi verir. BY.18 \u00c7al\u0131\u015fma s\u0131ras\u0131nda i\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi kurallar\u0131n\u0131 uygular. BY.19 \u00c7al\u0131\u015fma s\u00fcresince, \u00e7al\u0131\u015fma ortam\u0131n\u0131n g\u00fcvenli\u011fini sa\u011flamak i\u00e7in uyar\u0131 i\u015faret ve levhalar\u0131n\u0131 talimatlar do\u011frultusunda yerle\u015ftirerek \u00e7al\u0131\u015fma boyunca muhafaza eder. BY.20 Yapaca\u011f\u0131 i\u015flere g\u00f6re, talimatlara uygun ki\u015fisel koruyucu donan\u0131mlar\u0131n\u0131 (\u00f6zel koruyucu g\u00f6zl\u00fck, baret, g\u00fcvenlik ayakkab\u0131s\u0131, i\u015f k\u0131yafeti, emniyet kemeri gibi) kullan\u0131r. BY.21 \u0130\u015f s\u00fcre\u00e7lerinde \u00e7evre koruma gerekliliklerini uygular. BY.22 \u0130\u015f s\u00fcre\u00e7lerinde kalite gerekliliklerini uygular. Uygulama Faaliyeti 1: Evirici DC Giri\u015f b\u00f6l\u00fcm\u00fcnde yer alan dizi kablolar\u0131nda izolasyon \u00f6l\u00e7\u00fcmlerini yaparak, \u00f6l\u00e7\u00fcm sonu\u00e7lar\u0131n\u0131 kay\u0131t alt\u0131na al\u0131n\u0131z ve sonu\u00e7lar\u0131 de\u011ferlendirerek, standart de\u011ferlerin alt\u0131nda olan \u00f6l\u00e7\u00fcm sonu\u00e7lar\u0131na sahip dizileri ay\u0131r\u0131n\u0131z. \u00d6l\u00e7\u00fcm ve kontroller esnas\u0131nda \u00e7evre g\u00fcvenli\u011fi, \u0130SG talimatlar\u0131, KKD kullan\u0131mlar\u0131na ve kalite gerekliliklerinin uygulanmas\u0131na \u00f6zen g\u00f6steriniz. MOD\u00dcL 6 - 113","\u0130\u015flem Ad\u0131mlar\u0131 Dikkat Edilecek Hususlar \u00d6l\u00e7\u00fcm yap\u0131lacak eviricinin bulundu\u011fu alanda, test ve \u00f6l\u00e7\u00fcm yap\u0131lmas\u0131na ili\u015fkin \u00e7evre g\u00fcvenli\u011fi Devreden \u00c7\u0131karma, Devreye Alma, Elektrik uyar\u0131 i\u015faret ve levhalar ile ve\/veya s\u00f6zl\u00fc ileti\u015fim panolar\u0131nda g\u00fcvenli \u00e7al\u0131\u015fma vb. ve bilgilendirme ile ilgili birimlere bildirilir. \u0130lgili ISG talimatlar\u0131 g\u00f6zden ge\u00e7irilir. Anormal bir durum ile kar\u015f\u0131la\u015f\u0131lmas\u0131 halinde, bu durum kay\u0131t alt\u0131na al\u0131n\u0131r (foto\u011fraf, video \u0130\u015fe uygun KKD ku\u015fan\u0131l\u0131r. (Elektrik\u00e7i yard\u0131m\u0131yla) periyodik \u00f6l\u00e7\u00fcm ertelenir ve Ayakkab\u0131s\u0131, AG eldiven, Baret, G\u00f6zl\u00fck, \u0130\u015f eviricinin o anki durumu ile ilgilenilir. \u0130lgili K\u0131yafeti anormal durum sonu\u00e7land\u0131r\u0131l\u0131nca tekrar \u00f6l\u00e7\u00fcm \u00d6l\u00e7\u00fcm yap\u0131lacak eviricinin genel g\u00f6zle ad\u0131mlar\u0131na devam edilir. kontrolleri yap\u0131larak herhangi bir anormal \u00c7al\u0131\u015fmaya ba\u015flamadan \u00f6nce gerekli KKD\u2019leri duruma sahip olup olmad\u0131\u011f\u0131 kontrol edilir. ku\u015fan\u0131n\u0131z ve ISG talimatlar\u0131na uyunuz. DC ve AC k\u0131s\u0131mdan eviricinin enerjisi keserek, en az 15 \u00d6l\u00e7\u00fcm yap\u0131lacak eviricinin enerjisi kesilir. dakika de\u015farj s\u00fcresini bekleyiniz. Evirici \u2013 devre kesici hatt\u0131nda yer alan k\u0131s\u0131mda Evirici devreden \u00e7\u0131karma talimatlar\u0131n\u0131 uygulay\u0131p, evirici taraf\u0131na giden kablo hatt\u0131ndan \u00f6l\u00e7\u00fcm de\u015farj s\u00fcresini bekledikten sonra Evirici AC al\u0131n\u0131z. ba\u011flant\u0131 hatt\u0131nda yer alan ve \u00f6l\u00e7\u00fcm alabilece\u011finiz ilk noktadan gerilim \u00f6l\u00e7\u00fcm\u00fc EKED uygulamas\u0131, enerjisi kesilen devre yap\u0131n\u0131z ve gerilim \u201c0\u201d oldu\u011funa emin olunuz. \u00fczerinde ba\u015fka kimselerin, \u00e7al\u0131\u015fma yap\u0131l\u0131p AC k\u0131s\u0131mda devre kesme uygulamalar\u0131nda yap\u0131lmad\u0131\u011f\u0131n\u0131 bilmesine bakmaks\u0131z\u0131n devreyi EKED kullan\u0131l\u0131p kullan\u0131lmad\u0131\u011f\u0131na dikkat edilir. bilgi aktar\u0131m\u0131 ve haber vermeden tekrar Enerjiyi i\u015fletme birim ekiplerinin kesmesi enerjilendirememesi i\u00e7in g\u00fcvenli ve gerekli bir durumunda EKED uygulamas\u0131 yapmalar\u0131 istenir. uygulamad\u0131r. Dizi konekt\u00f6rlerini s\u00f6kerken, AG eldiven Dizi ba\u011flant\u0131lar\u0131n\u0131 uygun el aleti kullanarak giymeyi unutmay\u0131n\u0131z. yerinden \u00e7\u0131kar\u0131n\u0131z. (Konekt\u00f6r s\u00f6kme pensesi) Ba\u011flant\u0131lar\u0131n do\u011fru yap\u0131ld\u0131\u011f\u0131na emin olunuz, Dizi konekt\u00f6rlerini s\u00f6kerek bo\u015fa ald\u0131ktan sonra detayl\u0131 ba\u011flant\u0131 \u015femas\u0131 i\u00e7in cihaz\u0131n\u0131z\u0131n kullan\u0131m \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131 a\u00e7\u0131n\u0131z ve \u201c+\u201d prob ucunu \u201c+\u201d dc k\u0131lavuzunu inceleyiniz. konekt\u00f6r ucuna, \u201c-\u201c prob ucunu \u201c-\u201c konekt\u00f6r ucuna yerle\u015ftiriniz. \u0130lgili ayarlama i\u00e7in cihaz\u0131n\u0131z\u0131n kullan\u0131m Dizi sistem gerilimi hangi seviyede ise k\u0131lavuzunu inceleyiniz. cihaz\u0131n\u0131z\u0131n gerilim kademesini ilgili ayara getiriniz. 1000V sistem gerilimi i\u00e7in 1000V, S\u00fcrekli \u00f6l\u00e7\u00fcm veya anl\u0131k \u00f6l\u00e7\u00fcm metotlar\u0131 i\u00e7in 1500V sistem gerilimi i\u00e7in 1500V uygulayan\u0131z. cihaz\u0131n\u0131z\u0131n kullan\u0131m k\u0131lavuzunu inceleyiniz. Ba\u011flant\u0131 ve ayarlamalar\u0131 yapt\u0131ktan sonra test tu\u015funa bas\u0131n\u0131z ve \u00f6l\u00e7\u00fcm\u00fcn tamamlanmas\u0131n\u0131 \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131z\u0131n kay\u0131t \u00f6zelli\u011fi ve ayarlar\u0131 i\u00e7in bekleyiniz. cihaz\u0131n\u0131z\u0131n kullan\u0131m k\u0131lavuzunu inceleyiniz. \u00d6l\u00e7\u00fcm sonucunu kaydediniz ve \u00e7\u0131kan sonucun \u00d6l\u00e7\u00fcm cihaz\u0131n\u0131zda kay\u0131t \u00f6zelli\u011fi yok ise \u00e7\u0131kan standart de\u011ferlerin \u00fczerinde olup olmad\u0131\u011f\u0131 sonucu foto\u011fraflay\u0131n\u0131z veya defterinize not konusunda ilk g\u00f6r\u00fc\u015flerinizi not ediniz. al\u0131n\u0131z. Di\u011fer dizeler i\u00e7in izolasyon \u00f6l\u00e7\u00fcmlerini yap\u0131n\u0131z Etiketi olmayan diziler i\u00e7in demontaj a\u015famas\u0131nda ve i\u015flem bitene kadar s\u00fcrd\u00fcr\u00fcn\u00fcz. etiketleme yap\u0131n\u0131z. Etiketleme yap\u0131lamayan \u00d6l\u00e7\u00fcmler bittikten sonra, ilgili dizileri evirici durumlar i\u00e7in \u00f6l\u00e7\u00fcmleri tek tek s\u0131rayla yap\u0131n\u0131z ve taraf\u0131ndan etiketlerine uygun olarak yerlerine MOD\u00dcL 6 - 114","tak\u0131n\u0131z. Ba\u011flant\u0131lar\u0131n\u0131n yap\u0131lmas\u0131yla beraber \u00f6l\u00e7\u00fcm\u00fc biten ve sonu\u00e7lar\u0131 standart de\u011ferlerin gev\u015feklik olu\u015fmamas\u0131 i\u00e7in \u00e7ift kontrol yap\u0131n\u0131z. \u00fczerinden olan dizileri yerlerine tak\u0131n\u0131z, olmayanlar\u0131n u\u00e7lar\u0131n\u0131 bantlay\u0131n\u0131z. Dizilerin yerlerine do\u011fru \u015fekilde tak\u0131lmas\u0131n\u0131n E\u011fer evirici ekran\u0131, DC hatt\u0131n kapat\u0131lmas\u0131 ile ard\u0131ndan, evirici genel g\u00f6zle kontrolleri yap\u0131p, a\u00e7\u0131l\u0131yorsa, evirici ekran\u0131nda DC b\u00f6l\u00fcm ile ilgili DC devre ay\u0131r\u0131c\u0131lar\u0131n devre hatt\u0131n\u0131 kapal\u0131 herhangi bir anormal durum olup olmad\u0131\u011f\u0131n\u0131 konuma getiriniz. g\u00f6zlemleyiniz. AC ile beslenen ekranlarda AC gerilimin verilmesinin ard\u0131ndan gerekli DC devreleri kapal\u0131 ve herhangi bir sorun kontrolleri yap\u0131n\u0131z. olmayan eviricinin AC besleme hatt\u0131n\u0131, a\u00e7ma Gerilimlerin normal seviyelerde oldu\u011funu teyit yap\u0131lan noktadan tekrar kapat\u0131n\u0131z ve faz-faz, faz- ediniz. n\u00f6tr gerilim \u00f6l\u00e7\u00fcmlerini evirici taraf\u0131ndan giden hat \u00fczerinden yap\u0131n\u0131z. Devreye alma a\u015famalar\u0131nda eviricide meydana Eviricinin, devreye girme sekans\u0131n\u0131n gelen anormal durumlar \/ mesajlar ortaya tamamlanmas\u0131n\u0131 bekleyiniz ve devreye girme \u00e7\u0131kmas\u0131 durumunda, hata mesajlar\u0131 i\u00e7in evirici durumunu g\u00f6zlemleyiniz. kullan\u0131m k\u0131lavuzunu inceleyiniz. Evirici devreye girmesinin ard\u0131ndan, t\u00fcm \u00f6l\u00e7\u00fcm sonu\u00e7lar\u0131n\u0131 tekrar g\u00f6zden ge\u00e7iriniz ve kay\u0131t alt\u0131na al\u0131n\u0131z. \u0130\u015flem sonras\u0131, gerekli \u00e7evre g\u00fcvenlik \u00f6nlemlerini kald\u0131rabilirsiniz. BY.10 Mekanik sistem kontrol\u00fcn\u00fcn yap\u0131laca\u011f\u0131 en az 2 ba\u011flant\u0131 noktas\u0131n\u0131 belirler. BY.11 Belirledi\u011fi kontrol noktalar\u0131nda, sistem ba\u011flant\u0131lar\u0131nda gev\u015feme olup olmad\u0131\u011f\u0131n\u0131 tork anahtar\u0131 ile kontrol eder. BY.12 Mekanik sistemin \u00f6l\u00e7\u00fcm ve muayene sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 uygunsuzluklar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. Uygulama Faaliyeti-2: Yer tipi bir fotovoltaik g\u00fc\u00e7 santralinde, panel ta\u015f\u0131y\u0131c\u0131 sistemlerinde a\u015f\u0131k ve kiri\u015f hatlar\u0131ndaki ba\u011flant\u0131larda c\u0131vatalar\u0131n s\u0131k\u0131l\u0131k gev\u015feklik durumlar\u0131n\u0131 tork anahtar\u0131 ile kontrol ediniz ve uygun olmayan durumlar\u0131 a\u00e7\u0131\u011fa \u00e7\u0131kararak kay\u0131t alt\u0131na al\u0131n\u0131z. \u00d6l\u00e7\u00fcm ve kontroller esnas\u0131nda \u00e7evre g\u00fcvenli\u011fi, \u0130SG talimatlar\u0131, KKD kullan\u0131mlar\u0131na ve kalite gerekliliklerinin uygulanmas\u0131na \u00f6zen g\u00f6steriniz. \u0130\u015flem Ad\u0131mlar\u0131 Dikkat Edilecek Hususlar \u00d6l\u00e7\u00fcm yap\u0131lacak alanda, test ve \u00f6l\u00e7\u00fcm Anormal bir durum ile kar\u015f\u0131la\u015f\u0131lmas\u0131 halinde, bu yap\u0131lmas\u0131na ili\u015fkin \u00e7evre g\u00fcvenli\u011fi uyar\u0131 i\u015faret durum kay\u0131t alt\u0131na al\u0131n\u0131r (foto\u011fraf, video ve levhalar ile ve\/veya s\u00f6zl\u00fc ileti\u015fim ve yard\u0131m\u0131yla) bilgilendirme ile ilgili birimlere bildirilir. \u0130lgili ISG talimatlar\u0131 g\u00f6zden ge\u00e7irilir. \u0130\u015fe uygun KKD ku\u015fan\u0131l\u0131r. (Ayakkab\u0131, Baret, G\u00f6zl\u00fck, \u0130\u015f K\u0131yafeti) \u00d6l\u00e7\u00fcm ve kontrol yap\u0131lacak alanda olumsuz bir durum olup olmad\u0131\u011f\u0131 g\u00f6zle kontrol edilir. MOD\u00dcL 6 - 115","A\u015f\u0131k ve Kiri\u015flerin ta\u015f\u0131y\u0131c\u0131 sistemin hangi A\u015f\u0131k diye adland\u0131r\u0131lan k\u0131s\u0131mlar yatay ta\u015f\u0131y\u0131c\u0131 par\u00e7alar\u0131 oldu\u011funa emin olun. profiller, kiri\u015f diye adland\u0131r\u0131lan k\u0131s\u0131mlar dikey destek profilleridir. Ba\u011flant\u0131 noktalar\u0131ndaki c\u0131vatalar\u0131n metrik \u00f6l\u00e7\u00fcs\u00fcn\u00fc belirleyiniz. Kumpas yard\u0131m\u0131yla c\u0131vata Kullan\u0131m ve ayarlama detaylar\u0131 i\u00e7in Tork ba\u015fl\u0131k \u00f6l\u00e7\u00fcs\u00fcn\u00fc \u00f6l\u00e7erek de Tork s\u0131kma tablosuna anahtar\u0131n\u0131n kullan\u0131m k\u0131lavuzuna bak\u0131n\u0131z. g\u00f6re ilgili s\u0131kma torkunun hangi de\u011fer \/ de\u011fer aral\u0131\u011f\u0131nda olaca\u011f\u0131n\u0131 belirleyiniz. Tork m\u00fchr\u00fc, gev\u015feyen c\u0131vatalar\u0131n d\u00f6nmesi Tork anahtar\u0131ndaki ilgili s\u0131kma tork de\u011ferini sebebiyle, \u00e7ekilen \u00e7izgide bozukluk yarataca\u011f\u0131 ayarlayarak, Tork anahtar\u0131 ile c\u0131vata tork s\u0131kma i\u00e7in bir sonraki kontrollerde tork m\u00fch\u00fcrlerini i\u015flemini ger\u00e7ekle\u015ftiriniz. kontrol etmek kolayl\u0131k sa\u011flayacakt\u0131r. Tork s\u0131kma i\u015flemi sonras\u0131, c\u0131vata ba\u015fl\u0131\u011f\u0131 ile sabit y\u00fczey aras\u0131na bir tork m\u00fchr\u00fc \u00e7izgisini silinmeyen kalem ile i\u015faretleyiniz. Gev\u015fek ve \u00e7ok s\u0131k\u0131lm\u0131\u015f olan ba\u011flant\u0131lar ile kar\u015f\u0131la\u015f\u0131l\u0131rsa ilgili bulgular\u0131 kay\u0131t alt\u0131na al\u0131n\u0131z. Kontrol sonucunda gerekli \u00e7evre g\u00fcvenlik \u00f6nlemlerini ortadan kald\u0131r\u0131n\u0131z. BY.13 Panellerin ve di\u011fer ekipmanlar\u0131n (kablo tavas\u0131, pano vb.) temizli\u011fini kontrol eder. BY.14 Panellerin ve di\u011fer ekipmanlar\u0131n temizli\u011fi ile ilgili kontrol sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 aksakl\u0131klar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. Uygulama Faaliyeti-3: \u00c7at\u0131 tipi bir fotovoltaik g\u00fc\u00e7 santralinde, saha tali panosu, GES Panosu, DC Toplama Panosu, AC Toplama Panosu i\u00e7 k\u0131s\u0131mlar\u0131n\u0131 g\u00f6rsel, i\u015fitsel ve termal kamera ile kontrol ediniz ve uygun olmayan durumlar\u0131 a\u00e7\u0131\u011fa \u00e7\u0131kararak kay\u0131t alt\u0131na al\u0131n\u0131z. \u00d6l\u00e7\u00fcm ve kontroller esnas\u0131nda \u00e7evre g\u00fcvenli\u011fi, \u0130SG talimatlar\u0131, KKD kullan\u0131mlar\u0131na ve kalite gerekliliklerinin uygulanmas\u0131na \u00f6zen g\u00f6steriniz. \u0130\u015flem Ad\u0131mlar\u0131 Dikkat Edilecek Hususlar \u00d6l\u00e7\u00fcm yap\u0131lacak alanda, test ve \u00f6l\u00e7\u00fcm yap\u0131lmas\u0131na ili\u015fkin \u00e7evre g\u00fcvenli\u011fi uyar\u0131 i\u015faret ve levhalar ile ve\/veya s\u00f6zl\u00fc ileti\u015fim ve bilgilendirme ile ilgili birimlere bildirilir. \u0130lgili ISG talimatlar\u0131 g\u00f6zden ge\u00e7irilir. \u0130\u015fe uygun KKD ku\u015fan\u0131l\u0131r (Ayakkab\u0131, Baret, G\u00f6zl\u00fck, \u0130\u015f K\u0131yafeti). \u00d6l\u00e7\u00fcm ve kontrol yap\u0131lacak alanda olumsuz bir Anormal bir durum ile kar\u015f\u0131la\u015f\u0131lmas\u0131 halinde, bu durum olup olmad\u0131\u011f\u0131 g\u00f6zle kontrol edilir. durum kay\u0131t alt\u0131na al\u0131n\u0131r (foto\u011fraf, video yard\u0131m\u0131yla) \u00d6l\u00e7\u00fcm ve kontrol yap\u0131lacak panolarda pano kapaklar\u0131 d\u00fczg\u00fcn ve uygun bir \u015fekilde a\u00e7\u0131l\u0131r. MOD\u00dcL 6 - 116","Panoda yap\u0131lacak kontrollerde yakla\u015f\u0131m mesafeleri g\u00f6zetilerek kontrol ad\u0131mlar\u0131 uygulan\u0131r. G\u00f6rsel, \u0130\u015fitsel ve Termal kontrolleri panolar\u0131n Panoda var olan olumsuz bulgular\u0131n i\u015fitsel, y\u00fck alt\u0131nda oldu\u011fu zaman dilimlerinde g\u00f6rsel ve termal kamera ile bulunabilmesi ad\u0131na m\u00fcmk\u00fcnse tepe g\u00fc\u00e7 de\u011ferine yak\u0131n vakitlerde sisteminde devrede ve nominal g\u00fc\u00e7 seviyelerine kontrol ediniz. yak\u0131n zamanlarda kontrol edilmesi \u00f6nemlidir. %10-%20 kapasite ile \u00e7al\u0131\u015fan sistem \u00e7\u0131k\u0131\u015f\u0131ndaki ak\u0131m miktar\u0131 ile %70-80 band\u0131nda \u00e7al\u0131\u015fan sistem \u00e7\u0131k\u0131\u015f ak\u0131m miktar\u0131 aras\u0131ndaki farkl\u0131l\u0131\u011fa ba\u011fl\u0131 olarak \u0131s\u0131nma oranlar\u0131 da farkl\u0131l\u0131k g\u00f6sterecektir. \u0130\u015fitsel olarak yap\u0131lan kontrollerde herhangi anormal ses duyuldu\u011funda video ile kay\u0131t alt\u0131na al\u0131n\u0131z. G\u00f6rsel kontrollerde, kar\u015f\u0131la\u015f\u0131lan olumsuz durumlar\u0131 foto\u011fraf ve video ile kay\u0131t alt\u0131na al\u0131n\u0131z. Termal kamera ile yap\u0131lacak kontrollerde, pano Ba\u011flant\u0131larda gev\u015feklikler var ise bu noktada i\u00e7erisindeki ba\u011flant\u0131 noktalar\u0131 ve koruma diren\u00e7 etkisi ile \u0131s\u0131nma olacakt\u0131r. Ekipman i\u00e7 ekipmanlar\u0131n\u0131n termal kamerada minimum ve k\u0131sm\u0131ndaki bozukluklar sebebiyle yine bu maksimum s\u0131cakl\u0131k g\u00f6stergeleri ile kontrol\u00fc noktalarda \u0131s\u0131nmalar meydana gelebilecektir. Bu yap\u0131larak \u0131s\u0131 farkl\u0131l\u0131klar\u0131 bulunan noktalar\u0131n tip kar\u015f\u0131la\u015f\u0131lan durumlarda \u0131s\u0131nan nokta ile kay\u0131tlar\u0131n\u0131 al\u0131n\u0131z. normal \u0131s\u0131ya sahip nokta ayn\u0131 kadraja al\u0131narak foto\u011fraf kayd\u0131 al\u0131nmas\u0131, sonras\u0131nda yap\u0131lacak analiz ve raporlama i\u00e7in faydal\u0131 olacakt\u0131r. T\u00fcm kontroller yap\u0131ld\u0131ktan sonra pano kapaklar\u0131n\u0131 d\u00fczg\u00fcn ve uygun \u015fekilde kapat\u0131n\u0131z ve kilitleyiniz. Kontrol sonucunda gerekli \u00e7evre g\u00fcvenlik \u00f6nlemlerini ortadan kald\u0131r\u0131n\u0131z. Kontrol sonras\u0131nda, \u00e7evre g\u00fcvenlik \u00f6nlemlerini kapatabilirsiniz. BY.15 Panellerin k\u0131smi g\u00f6lgelenmesine neden olan \u00e7evresel etkileri kontrol eder. BY.16 K\u0131smi g\u00f6lgelenmeye neden olan \u00e7evresel etkiler ile ilgili kontrol sonucuna g\u00f6re kar\u015f\u0131la\u015ft\u0131\u011f\u0131 aksakl\u0131klar\u0131 gidererek gideremedi\u011fi aksakl\u0131klar\u0131 kay\u0131t alt\u0131na al\u0131r. Uygulama Faaliyeti-4: \u0130\u015flem Ad\u0131mlar\u0131 Dikkat Edilecek Hususlar \u00d6l\u00e7\u00fcm yap\u0131lacak alanda, test ve \u00f6l\u00e7\u00fcm yap\u0131lmas\u0131na ili\u015fkin \u00e7evre g\u00fcvenli\u011fi uyar\u0131 i\u015faret ve levhalar ile ve\/veya s\u00f6zl\u00fc ileti\u015fim ve bilgilendirme ile ilgili birimlere bildirilir. MOD\u00dcL 6 - 117","\u0130lgili ISG talimatlar\u0131 g\u00f6zden ge\u00e7irilir. \u0130\u015fe uygun KKD ku\u015fan\u0131l\u0131r. (Ayakkab\u0131, Baret, G\u00f6zl\u00fck, \u0130\u015f K\u0131yafeti) \u00d6l\u00e7\u00fcm ve kontrol yap\u0131lacak alanda olumsuz bir Anormal bir durum ile kar\u015f\u0131la\u015f\u0131lmas\u0131 halinde, bu durum olup olmad\u0131\u011f\u0131 g\u00f6zle kontrol edilir. durum kay\u0131t alt\u0131na al\u0131n\u0131r (foto\u011fraf, video yard\u0131m\u0131yla) Panellerde g\u00f6lgelenmeye sebebiyet verecek Kirlilik, Bitki veya Yap\u0131 g\u00f6lgeleri, Hayvan bulgular\u0131n tespiti i\u00e7in g\u00f6zle kontroller yap\u0131l\u0131r. Pisli\u011fi vb. panel \u00f6n y\u00fczeylerinde panel h\u00fccrelerine g\u00f6lge unsuru olu\u015fturacak durumlar ortaya konur. Panel h\u00fccrelerine g\u00f6lgeleme yapan unsurlar belirlendik\u00e7e, m\u00fcmk\u00fcnse termal kontrol ile h\u00fccre \u0131s\u0131 farkl\u0131l\u0131klar\u0131 \u00f6l\u00e7\u00fcl\u00fcr ve kay\u0131t alt\u0131na al\u0131n\u0131r. G\u00f6rsel kontrol sonu\u00e7lar\u0131n\u0131n her biri, foto\u011fraf ve \/ Bulgu tespit edilen noktalar\u0131n etiketlemesi veya video ile kay\u0131t alt\u0131na al\u0131n\u0131r. (panelin sahan\u0131n neresinde hangi konumda oldu\u011funu belirtir kay\u0131t) yap\u0131l\u0131r. Panellerde \u00f6zellikle kirlilik unsurlar\u0131n\u0131n oldu\u011fu Panellerin y\u0131kanmas\u0131 ile ilgili olarak havalar\u0131n g\u00f6lgeleme etkileri bertaraf etmek \u00fczere, panel \u00e7ok s\u0131cak oldu\u011fu vakitlerde, panel y\u00fczeyine uygulanacak suyun \u0131s\u0131 derecesi d\u00fc\u015f\u00fck ise y\u0131kama talimatlar\u0131 uygulan\u0131r. h\u00fccrelerde k\u0131sa s\u00fcreli termal \u015fok etkisi yaratmayacak zaman dilimleri se\u00e7ilebilir y\u0131kama i\u00e7in en uygun zaman dilimi olarak se\u00e7ilebilir. Sabah 08:00-10:00, Ak\u015fam 16:00 ve sonras\u0131 gibi. Y\u0131kama uygulamalar\u0131 sonucunda kirlilik unsurlar\u0131n\u0131n bertaraf edilip edilmedi\u011fi kontrol edilir. Kirlilik sebebiyle kirlenme unsurunun Y\u0131kama ile beraber ilgili h\u00fccre veya h\u00fccrelerde bulundu\u011fu h\u00fccre ve h\u00fccre blo\u011funda olu\u015fmas\u0131 k\u0131sa s\u00fcreli hot spot olay\u0131 devam edebilir. Bu muhtemel \u0131s\u0131nmalar\u0131n, y\u0131kama sonras\u0131 durumu noktada bu panellerde termal kontrollerin 1 ay termal kamera ile kontrol edilir. i\u00e7erisinde tekrar\u0131n\u0131n yap\u0131lmas\u0131 \u00f6nerilmektedir. Kal\u0131c\u0131 hot spot olu\u015fumlar\u0131 genellikle \u0131s\u0131nan h\u00fccre ile normal h\u00fccre aras\u0131nda 20 \u00b0C ve \u00fczeri \u0131s\u0131 farkl\u0131l\u0131klar\u0131nda ortaya \u00e7\u0131kmaktad\u0131r. Kal\u0131c\u0131 hot spot olmas\u0131 halinde panelin yenisiyle de\u011fi\u015fimi \u00f6nerilmektedir. Kontrol ve \u00f6l\u00e7\u00fcm uygulamalar\u0131n\u0131n tamamlanmas\u0131 sonucunda gerekli \u00e7evre g\u00fcvenlik \u00f6nlemlerini ortadan kald\u0131r\u0131n\u0131z. MOD\u00dcL 6 - 118","KONU 13 \u00d6L\u00c7ME VE DE\u011eERLEND\u0130RME SORULARI Her bir mod\u00fcldeki \u00f6l\u00e7me-de\u011ferlendirme k\u0131sm\u0131nda; \u00f6ncelikle Fotovoltaik G\u00fc\u00e7 Sistemleri Personeli (Seviye 5) Ulusal Yeterlili\u011fi Teorik S\u0131nav ba\u015fl\u0131\u011f\u0131 alt\u0131nda belirlenmi\u015f \u201cBilgi (BG)\u201d kontrol listesine g\u00f6re test sorular\u0131n\u0131n haz\u0131rlanmas\u0131 gerekti\u011fi dikkate al\u0131nmal\u0131d\u0131r. E\u011fer Ulusal Yeterlilik dosyas\u0131nda mevcut Mod\u00fcl i\u00e7eri\u011fine direkt hitap eden bir teorik s\u0131nav uygulamas\u0131 yoksa (\u00f6rne\u011fin Mod\u00fcl 1 ve Mod\u00fcl 3 i\u00e7in), bu durumdaki test sorular\u0131n\u0131n sadece mevcut mod\u00fcl i\u00e7in listelenmi\u015f \u00f6\u011frenme kazan\u0131mlar\u0131n\u0131 \u00f6l\u00e7ecek \u015fekilde geli\u015ftirilmesi \u00f6nerilmektedir. MOD\u00dcL 6 \u0130\u00c7\u0130N \u00d6RNEK TEST SINAVI SORULARI BG.1 Bak\u0131m i\u00e7in gerekli ekipmanlar\u0131 a\u00e7\u0131klar. Soru 1: A\u015fa\u011f\u0131dakilerden hangisi ta\u015f\u0131y\u0131c\u0131 sistem bak\u0131m kontrollerinde kullan\u0131lmaz? A: Tork Anahtar\u0131 B: Galvaniz Kal\u0131nl\u0131k \u00d6l\u00e7\u00fcm Cihaz\u0131 C: Su terazisi D: Termal Kamera Soru 2: A\u015fa\u011f\u0131dakilerden hangisi elektriksel bak\u0131m kontrollerinde kullan\u0131lmaz? A: Multimetre B: Toprak Megeri C: \u0130zolasyon \u00d6l\u00e7\u00fcm Aleti D: Kumpas Soru 3: Elektriksel bak\u0131m kontrollerinde kablo iletkeni ile d\u0131\u015f k\u0131l\u0131f aras\u0131nda veya toprak noktas\u0131na ka\u00e7ak ak\u0131m\u0131n varl\u0131\u011f\u0131n\u0131 \u00f6l\u00e7en cihaz a\u015fa\u011f\u0131dakilerden hangisidir? A: \u0130zolasyon \u00d6l\u00e7\u00fcm Cihaz\u0131 B: Termal Kamera C: Tork Anahtar\u0131 D: Kumpas BG.2 Bak\u0131m s\u0131ras\u0131nda enerjisi kesilecek noktalar\u0131n nereler olaca\u011f\u0131n\u0131 a\u00e7\u0131klar. Soru 4: Dizi a\u00e7\u0131k devre gerilimi \u00f6l\u00e7\u00fclmesi istenen bir evirici giri\u015finde bulunan dizi kablolar\u0131n\u0131n s\u00f6k\u00fclmeden \u00f6nce, Eviriciye ait AC devre kesicisinin kapat\u0131lmas\u0131 yeterlidir! (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 5: Evirici AC giri\u015finde ak\u0131m \u00f6l\u00e7\u00fcm\u00fc yap\u0131lmas\u0131 istenmesi halinde, eviricinin hem DC hem AC devre kesicilerin kapat\u0131lmas\u0131 gerekmektedir! (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 6: Eviricide kontrol yapmak \u00fczere devreden \u00e7\u0131kar\u0131lmas\u0131 gerekti\u011fi durumlarda sadece AC devre kesicinin kapat\u0131lmas\u0131 yeterlidir? (Do\u011fru? \/ Yanl\u0131\u015f?) BG.3 Panolardaki DA (DC) ak\u0131m ile ilgili olarak al\u0131nmas\u0131 gereken \u00f6nlemleri a\u00e7\u0131klar. BG.4 Fotovoltaik sistemlerin bak\u0131m s\u00fcre\u00e7lerini a\u00e7\u0131klar. Soru 7: A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik g\u00fc\u00e7 sistemlerinde test edilerek \u00f6l\u00e7\u00fcmlenen veriler \u00fczerinden analizi yapmak i\u00e7in yap\u0131lan bak\u0131m kontrol y\u00f6ntemlerinden biridir? MOD\u00dcL 6 - 119","A: El ile Kontrol B: G\u00f6z ile Kontrol C: \u0130\u015fitsel Kontrol D: \u00d6l\u00e7\u00fc Aleti ile Kontrol Soru 8: A\u015fa\u011f\u0131dakilerden hangisi k\u0131sa periyotlar halinde ayn\u0131 noktalardan tekrarl\u0131 olarak al\u0131nan \u00f6l\u00e7\u00fcm verilerin analiz edilerek ar\u0131za analizi yapmaya y\u00f6nelik bak\u0131m kontrol uygulamas\u0131n\u0131n ad\u0131d\u0131r? A: \u00d6nleyici Bak\u0131m B: D\u00fczenleyici Bak\u0131m C: Acil Bak\u0131m D: Kestirimci Bak\u0131m Soru 9: A\u015fa\u011f\u0131dakilerden hangisi fotovoltaik panellerde yap\u0131lan bak\u0131m kontrol s\u00fcre\u00e7lerinden biri de\u011fildir? A: Termal kamera ile kontrol B: Voc-Isc \u00d6l\u00e7\u00fcm\u00fc C: Galvaniz Kal\u0131nl\u0131\u011f\u0131 \u00d6l\u00e7\u00fcm\u00fc D: \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc BG.5 Par\u00e7alar\u0131n t\u00fcr\u00fcne g\u00f6re par\u00e7a de\u011fi\u015ftirme ad\u0131mlar\u0131n\u0131 a\u00e7\u0131klar. Soru 10: Fotovoltaik g\u00fc\u00e7 sistemlerinde, dizi kablosunun kemirgen taraf\u0131ndan zarar verilmesi halinde a\u015fa\u011f\u0131dakilerden hangi sonu\u00e7 ortaya \u00e7\u0131kar? A: \u0130zolasyon hatalar\u0131 meydana gelir ve g\u00fcvenlik tehdidi olu\u015fur. B: Panellerin verimlili\u011fi artar. C: Evirici verimlili\u011fi azal\u0131r. D: Dizi ak\u0131m\u0131 artar. Soru 11: Bak\u0131m kontrollerinde cam\u0131 \u00e7atlam\u0131\u015f panel tespit edilirse a\u015fa\u011f\u0131daki \u00e7al\u0131\u015fmalardan hangisi yap\u0131lmal\u0131d\u0131r? A: \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile elektrik alt\u0131nda \u00e7al\u0131\u015fma kurallar\u0131 g\u00f6zetilerek hasarl\u0131 panel yerinden s\u00f6k\u00fcl\u00fcr ve yeni panel tak\u0131l\u0131r. B: \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile elektrik alt\u0131nda \u00e7al\u0131\u015fma kurallar\u0131 g\u00f6zetilerek panel cam\u0131 yerinden \u00e7\u0131kar\u0131l\u0131r ve yerine yeni cam tak\u0131l\u0131r. C: \u00c7atlak cama sahip panellerde gerilim 0\u2019a do\u011fru d\u00fc\u015fer ancak herhangi bir i\u015flem yap\u0131lmas\u0131na gerek yoktur. D: \u00c7atlak cama sahip panel, bulundu\u011fu dizideki t\u00fcm paneller ile beraber de\u011fi\u015ftirilir. Soru 12: Bak\u0131m kontrollerinde evirici giri\u015f k\u0131sm\u0131nda konekt\u00f6r hasar\u0131 olan bir dizi i\u00e7in a\u015fa\u011f\u0131daki bak\u0131m uygulamalar\u0131ndan hangisi yap\u0131l\u0131r? A: \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile elektrik alt\u0131nda \u00e7al\u0131\u015fma kurallar\u0131 g\u00f6zetilerek hasarl\u0131 dizi ilgili yerden \u00e7\u0131kar\u0131l\u0131r, konekt\u00f6r yerinden s\u00f6k\u00fcl\u00fcr ve yeni konekt\u00f6r tak\u0131larak, dizi ilgili yerine tekrar tak\u0131l\u0131r. B: \u0130\u015f sa\u011fl\u0131\u011f\u0131 ve g\u00fcvenli\u011fi ile elektrik alt\u0131nda \u00e7al\u0131\u015fma kurallar\u0131 g\u00f6zetilerek hasarl\u0131 dizi ilgili yerden \u00e7\u0131kar\u0131l\u0131r, konekt\u00f6r yerinden s\u00f6k\u00fcl\u00fcr ve kablo ucu bantlanarak k\u00f6rlenir. C: \u0130lgili konekt\u00f6r i\u00e7in herhangi bir i\u015flem yap\u0131lmaz. D: Hasarl\u0131 konekt\u00f6r ile beraber ilgili dizideki t\u00fcm konekt\u00f6r ba\u011flant\u0131lar\u0131 yenisiyle de\u011fi\u015ftirilir. BG.6 Fotovoltaik g\u00fc\u00e7 sistemlerinde olu\u015fabilecek (izolasyon, gev\u015feklik, a\u015f\u0131nma, oksitlenme, s\u0131zd\u0131rmazl\u0131k ve benzeri) sorunlar\u0131 a\u00e7\u0131klar. Soru 13: Korozyon problemleri fotovoltaik sistemlerde a\u015fa\u011f\u0131dakilerden hangisinde daha s\u0131k g\u00f6z\u00fck\u00fcr? A: Haberle\u015fme Hatlar\u0131 B: Mekanik Aksam C: AC Kablo Hatlar\u0131 D: Topraklama Hatlar\u0131 MOD\u00dcL 6 - 120","Soru 14: Paslanma olaylar\u0131n\u0131n sebepleri aras\u0131nda a\u015fa\u011f\u0131dakilerden hangisi g\u00f6sterilemez? A: Nem B: Oksijen C: Galvaniz Kal\u0131nl\u0131\u011f\u0131n\u0131n Az Olmas\u0131 D: Fotovoltaik Paneller Soru 15: A\u015fa\u011f\u0131dakilerden hangisi DC kablolarda izolasyon problemi ya\u015fanmas\u0131n\u0131n sebeplerinden de\u011fildir? A: \u0130\u015f\u00e7ilik Hatalar\u0131 B: Kemirgenler C: \u00dcr\u00fcn Hatalar\u0131 D: Bak\u0131m Kontrolleri BG.7 Fotovoltaik g\u00fc\u00e7 sistemlerinde olu\u015fabilecek (izolasyon, gev\u015feklik, a\u015f\u0131nma, oksitlenme, s\u0131zd\u0131rmazl\u0131k ve benzeri) sorunlar\u0131 giderme y\u00f6ntemlerini a\u00e7\u0131klar. Soru 16: Fotovoltaik g\u00fc\u00e7 sistemlerinin ta\u015f\u0131y\u0131c\u0131 konstr\u00fcksiyon k\u0131sm\u0131nda korozyon tespiti halinde, a\u015fa\u011f\u0131daki onar\u0131m eylemlerinin hangisi yap\u0131lmal\u0131d\u0131r? A: Korozyon b\u00f6lgesi su ile kapat\u0131lmal\u0131 B: Korozyon b\u00f6lgesi bant ile kaplanmal\u0131 C: Korozyon b\u00f6lgesi temizlenmeli ve galvanizlenmeli D: Herhangi bir i\u015flem yap\u0131lmas\u0131na gerek yoktur. Soru 17: Ta\u015f\u0131y\u0131c\u0131 konstr\u00fcksiyonda M10 \u00f6l\u00e7\u00fcs\u00fcnde ve 8.8 saplama kalitesinde c\u0131vata kullan\u0131lan ba\u011flant\u0131larda gev\u015feklik tespiti halinde tork anahtar\u0131 ile ka\u00e7 NM de\u011ferinde s\u0131k\u0131lmal\u0131d\u0131r? A: 50 B: 150 C: 250 D: 350 Soru 18: Dizi hatt\u0131nda izolasyon ar\u0131zas\u0131 olu\u015fmas\u0131 durumunda, izolasyon \u00f6l\u00e7\u00fcm\u00fcnde uygulanan gerilim 1000V ise, IEC ilgili standard\u0131na g\u00f6re minimum izolasyon direnci ka\u00e7 ohm olmas\u0131 beklenir? A: 2 B: 100 C: 500 D: 1000 BG.8 Bak\u0131m kapsam\u0131nda elektrik sisteminde \u00f6l\u00e7\u00fcm yap\u0131lacak noktalar\u0131 a\u00e7\u0131klar. Soru 19: Her biri ayn\u0131 Impp de\u011ferine sahip 10 adet dizinin, \u0131\u015f\u0131n\u0131m\u0131n 1000 W\/m2 oldu\u011fu a\u00e7\u0131k havada Impp ak\u0131m\u0131n\u0131n 10 A oldu\u011funu biliyorsak, DC Pano \u00e7\u0131k\u0131\u015f\u0131ndaki toplam DC ak\u0131m de\u011feri ka\u00e7t\u0131r? A: 10 A B: 1 A C: 100 A D: 20 A Soru 20: Dizilerde yap\u0131lan bak\u0131m kontrolleri aras\u0131nda a\u015fa\u011f\u0131dakilerden hangisi yoktur? A: Voc \u00d6l\u00e7\u00fcm\u00fc B: \u0130zolasyon \u00d6l\u00e7\u00fcm\u00fc C: Isc \u00d6l\u00e7\u00fcm\u00fc D: Frekans \u00d6l\u00e7\u00fcm\u00fc MOD\u00dcL 6 - 121","Soru 21: Eviricilerde yap\u0131lan bak\u0131m kontrolleri aras\u0131nda a\u015fa\u011f\u0131dakilerden hangisi yer almaz? A: DA-AA Verimlilik \u00d6l\u00e7\u00fcm\u00fc B: Fan Temizli\u011fi \/ Temizlik Kontrolleri C: DA ve AA ak\u0131m ve gerilim \u00d6l\u00e7\u00fcm\u00fc D: Mekanik Dayan\u0131m Testi BG.9 Bak\u0131m kapsam\u0131nda elektrik sisteminde \u00f6l\u00e7\u00fcm s\u00fcrecini a\u00e7\u0131klar. Soru 22: Eviricilerde fan ve temizlik kontrolleri yap\u0131lmas\u0131 istenirse, Eviricinin DA ve AA taraftan devreleri a\u00e7\u0131k pozisyona al\u0131n\u0131r ve de\u015farj olmas\u0131 i\u00e7in en az 15dk beklenilmesi gerekir. (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 23: Eviricinin ekran\u0131nda hata mesaj\u0131 olarak \u201cDA k\u0131sm\u0131nda izolasyon direnci d\u00fc\u015f\u00fck\u201d mesaj\u0131 g\u00f6r\u00fcld\u00fc\u011f\u00fcnde, evirici alternatif ak\u0131m kablolar\u0131nda izolasyon testi uygulanmal\u0131d\u0131r? . (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 24: Panellerde \u00e7al\u0131\u015fmayan h\u00fccreleri veya h\u00fccresel bozukluklar\u0131 sadece termal kontrol ile bulabiliriz? (Do\u011fru? \/ Yanl\u0131\u015f?) BG.10 Bak\u0131m kapsam\u0131nda mekanik sistemlerde \u00f6l\u00e7\u00fcm ve muayene yap\u0131lacak noktalar\u0131 a\u00e7\u0131klar. Soru 25: Panel Ta\u015f\u0131y\u0131c\u0131 Sistemlerinde yap\u0131lacak periyodik mekanik kontroller aras\u0131nda a\u015fa\u011f\u0131dakilerden hangisi bulunmaz? A: Tork Kontrol\u00fc B: Galvaniz Kal\u0131nl\u0131k Kontrol\u00fc C: Pas-Korozyon Kontrol\u00fc D: \u00c7ekme-\u00c7akma Testi Soru 26: Ta\u015f\u0131y\u0131c\u0131 sistemlerinde y\u0131ll\u0131k periyodik kontrollerin t\u00fcm ba\u011flant\u0131lar s\u00f6k\u00fcl\u00fcp, birbirleri aras\u0131nda yerleri de\u011fi\u015ftirilerek tekrar s\u0131k\u0131l\u0131r? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 27: Eviriciler, her zaman panellerin montajl\u0131 oldu\u011fu ta\u015f\u0131y\u0131c\u0131 sisteme ba\u011fl\u0131 olarak montajlanmal\u0131d\u0131r? (Do\u011fru? \/ Yanl\u0131\u015f?) BG.11 Bak\u0131m kapsam\u0131nda mekanik sistemlerde \u00f6l\u00e7\u00fcm- muayene s\u00fcrecini a\u00e7\u0131klar. Soru 28: Mekanik aksamda pas-korozyon tespiti halinde, galvaniz boya direkt olarak ilgili alanda ba\u015fka bir i\u015flem yap\u0131lmadan s\u00fcr\u00fclmelidir? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 29: M10 c\u0131vata \u00f6l\u00e7\u00fcs\u00fc ve \u00fczerindeki t\u00fcm c\u0131vatalarda Tork kontrol\u00fc uygulanmal\u0131d\u0131r ancak M10 c\u0131vata \u00f6l\u00e7\u00fcs\u00fc alt\u0131ndaki c\u0131vatalarda sadece pense ile kontrol yap\u0131lmal\u0131 ve gev\u015feklik halinde s\u0131k\u0131lmal\u0131d\u0131r? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 30: Yer tipi ta\u015f\u0131y\u0131c\u0131 sistemlerde \u00f6n ve arka ayaklarda her y\u0131l \u00e7ekme ve \u00e7akma testi yap\u0131lmal\u0131d\u0131r? (Do\u011fru? \/ Yanl\u0131\u015f?) BG.12 Enerji depolamal\u0131 sistemlerde, enerji depolama ekipman\u0131n\u0131n bak\u0131m a\u015famalar\u0131n\u0131 a\u00e7\u0131klar. Soru 31: Enerji depolamal\u0131 sistemlerde batarya gruplar\u0131nda termal test yap\u0131lmaz? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 32: Enerji depolamal\u0131 sistemlerde, evirici bak\u0131m kontrolleri s\u0131ras\u0131nda ak\u00fcler tamamen bo\u015falt\u0131lmal\u0131d\u0131r? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 33: Enerji depolamal\u0131 sistemlerde, ak\u00fclerin periyodik olarak kontrolleri yap\u0131l\u0131rken, eviricilerde ve panellerde \u00e7ok fazla periyodik kontrol yap\u0131lmas\u0131na gerek yoktur? (Do\u011fru? \/ Yanl\u0131\u015f?) MOD\u00dcL 6 - 122","BG.13 \u015eebeke ba\u011flant\u0131l\u0131 ve ba\u011flant\u0131s\u0131z sistemleri ve farklar\u0131n\u0131 a\u00e7\u0131klar. Soru 34: \u015eebeke ba\u011flant\u0131l\u0131 eviriciler, \u015febeke geriliminde ve frekans\u0131nda ya\u015fanacak dalgalanmalardan etkilenmezler? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 35: \u015eebeke ba\u011flant\u0131s\u0131z eviriciler, AA kayna\u011f\u0131n\u0131 DA kaynak formuna \u00e7evirerek \u015febeke sistemine verebilirler? (Do\u011fru? \/ Yanl\u0131\u015f?) Soru 36: \u015eebeke ba\u011flant\u0131l\u0131 sistemlerde eviriciler, \u015febeke gerilimi ve frekans\u0131n\u0131 referans olarak alaca\u011f\u0131 i\u00e7in \u015febeke olmad\u0131\u011f\u0131 durumlarda g\u00fc\u00e7 sa\u011flayamazlar? (Do\u011fru? \/ Yanl\u0131\u015f?) BG.14 K\u0131smi g\u00f6lgelenmeye neden olabilecek \u00e7evresel etkenleri a\u00e7\u0131klar. Soru 37: Panellere bir k\u0131sm\u0131na a\u011fa\u00e7 g\u00f6lgesi gelmesi sebebiyle ilgili panellerin bulundu\u011fu dizide a\u015fa\u011f\u0131daki durumlardan hangisinin meydana gelmesi beklenir? A: Dizi gerilimi yar\u0131 yar\u0131ya d\u00fc\u015fer. B: Dizi ak\u0131m\u0131 azal\u0131r. C: Ak\u0131m ve Gerilimde herhangi bir de\u011fi\u015fim olmaz. D: Dizi gerilimi iki kat\u0131na \u00e7\u0131kar. Soru 38: Bir Fotovoltaik Panelin bir b\u00f6l\u00fcm\u00fcnde kirlilik olmas\u0131 durumunda a\u015fa\u011f\u0131daki durumlardan hangisi ya\u015fan\u0131r? A: Kirli olan b\u00f6l\u00fcmdeki h\u00fccreler, di\u011fer temiz b\u00f6lgedeki h\u00fccrelere oranla daha fazla \u0131s\u0131n\u0131r. B: Paneldeki t\u00fcm h\u00fccreler hemen hemen ayn\u0131 seviyede \u0131s\u0131n\u0131r. C: Paneldeki kirli olan h\u00fccreler, di\u011fer h\u00fccrelerin s\u0131cakl\u0131\u011f\u0131ndan daha az s\u0131cakl\u0131\u011fa sahiptir. D: Kirlilik, herhangi bir anormal \u0131s\u0131nmaya sebebiyet vermez. Soru 39: A\u015fa\u011f\u0131dakilerden olaylardan hangisi panellerin \u00e7\u0131k\u0131\u015f ak\u0131m\u0131n\u0131n azalmas\u0131na sebep olan olaylardan biri de\u011fildir. A: Kirlilik B: Kar birikintisi C: A\u011fa\u00e7 G\u00f6lgesi D: G\u00fcr\u00fclt\u00fc MOD\u00dcL 6 - 123","MOD\u00dcL 6- CEVAP ANAHTARI 1) D 2) D 3) A 4) Yanl\u0131\u015f 5) Yanl\u0131\u015f 6) Yanl\u0131\u015f 7) D 8) D 9) C 10) A 11) A 12) A 13) B 14) D 15) C 16) C 17) A 18) A 19) C 20) D 21) D 22) Do\u011fru 23) Yanl\u0131\u015f 24) Yanl\u0131\u015f 25) D 26) Yanl\u0131\u015f 27) Yanl\u0131\u015f 28) Yanl\u0131\u015f 29) Yanl\u0131\u015f 30) Yanl\u0131\u015f 31) Yanl\u0131\u015f 32) Yanl\u0131\u015f 33) Yanl\u0131\u015f 34) Yanl\u0131\u015f 35) Yanl\u0131\u015f 36) Do\u011fru 37) B 38) A 39) D MOD\u00dcL 6 - 124","KONU 14 YETERL\u0130L\u0130K KONTROL L\u0130STES\u0130 Her bir mod\u00fcldeki yeterlilik kontrol k\u0131sm\u0131; Fotovoltaik G\u00fc\u00e7 Sistemleri Personeli (Seviye 5) Ulusal Standart Dosyas\u0131nda Listelenen Ba\u015far\u0131m \u00d6l\u00e7\u00fctleri dikkate al\u0131narak haz\u0131rlanm\u0131\u015ft\u0131r. E\u011fitmenlerin ve \u00d6\u011frencilerin bu k\u0131s\u0131mda belirtilen kontrol listesine g\u00f6re e\u011fitim ve \u00f6\u011frenme yeterlili\u011fini de\u011ferlendirmeleri \u00f6nerilmektedir. 14.1. Yeterlilik Kontrol Listesi-1 (Bak\u0131m \u00d6ncesi Haz\u0131rl\u0131k Yap\u0131lmas\u0131n\u0131 Sa\u011flamak ve Bak\u0131m \u0130\u015flerini Ger\u00e7ekle\u015ftirmek) Ba\u015far\u0131m \u00f6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri E.1.1 Bak\u0131m ve onar\u0131m i\u00e7in gerekli olan 1. Ak\u00fc bak\u0131m\u0131 2. Bak\u0131m alan\u0131 kontrol\u00fc E.1.2 ekipmanlar\u0131n haz\u0131rlanmas\u0131n\u0131 sa\u011flar. 1. 3. Ekip y\u00f6netimi 3. El aletleri kullanma E.1.3 Ak\u00fc bak\u0131m\u0131 4. Elektrik E.2.1 6. Elektrik devre \u015femas\u0131 okuma Bak\u0131m\u0131 yap\u0131lacak alan \u00e7evresinde 7. Elektrik sistemlerin \u00f6l\u00e7\u00fcm\u00fcn\u00fc yapma E.2.2 8. Elektriksel de\u011fer \u00f6l\u00e7me E.2.3 talimatta belirtilen g\u00fcvenlik \u00f6nlemlerinin 9. Etiketleme E.2.4 10. Fotovoltaik g\u00fc\u00e7 sistemleri ve bile\u015fenleri al\u0131nmas\u0131n\u0131 sa\u011flar. kontrol\u00fc ve bak\u0131m\u0131 E.2.5 11. Fotovoltaik sistemlerin elektriksel ve Bak\u0131m yapaca\u011f\u0131 alan\u0131n enerjisinin mekanik bile\u015fen montaj\u0131n\u0131 yapma E.2.6 12. \u0130\u015f formlar\u0131 doldurma ve kay\u0131t tutma kesilmesi i\u00e7in ilgili birime bilgi verir. 13. \u0130\u015faretleme yapma E.2.7 13. \u0130zolasyon \u00e7e\u015fitleri ve uygulamas\u0131 E.2.8 Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinde 14. Kablo \u00e7ekimi yapma E.2.9 16. Kablo \u00e7e\u015fitleri bak\u0131m kapsam\u0131nda yetkisi dahilinde 17. K\u0131smi g\u00f6lgelenme E.2.10 18. Konekt\u00f6r ba\u011flant\u0131s\u0131 yapma E.2.11 de\u011fi\u015fmesi gereken par\u00e7alar\u0131n 19. Malzeme \u00e7e\u015fitleri ve \u00f6zellikleri 20. Malzeme koruma E.2.12 de\u011fi\u015ftirilmesini sa\u011flar. 21. Malzeme ve ekipman kontrol\u00fc 22. Mekanik sistemlerin muayenesini ve Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinin \u00f6l\u00e7\u00fcm\u00fcn\u00fc yapma 23. \u00d6l\u00e7\u00fcm noktalar\u0131 belirleme g\u00f6rsel kontrollerinin yap\u0131lmas\u0131n\u0131 sa\u011flar. 23. Panel ve di\u011fer ekipman temizli\u011fi 24. Referans de\u011fer Elektrik sisteminde bak\u0131m kapsam\u0131nda 26. S\u00f6zl\u00fc ve yaz\u0131l\u0131 ileti\u015fim 27. \u015eebeke ba\u011flant\u0131l\u0131 ve ba\u011flant\u0131s\u0131z sistemler \u00f6l\u00e7\u00fcmlerin yap\u0131laca\u011f\u0131 noktalar\u0131 belirler. 28. \u015eebeke ba\u011flant\u0131l\u0131 ve ba\u011flant\u0131s\u0131z sistemlerde evirici kontrol\u00fc yapma Belirledi\u011fi \u00f6l\u00e7\u00fcm noktalar\u0131ndan elektrik 29. Talimat takibi 30. Teknik \u00e7izim ve proje\/plan okuma sisteminin \u00f6l\u00e7\u00fcm\u00fcn\u00fc talimata ve referans 31. Temel mekanik 32. Y\u00fcksekte \u00e7al\u0131\u015fma de\u011ferlere g\u00f6re yapar. 33. Bak\u0131m ve onar\u0131m i\u00e7in gerekli ekipmanlar, haz\u0131rl\u0131\u011f\u0131 ve kullan\u0131m\u0131 Mekanik sistemlerin \u00f6l\u00e7\u00fcmlerinin ve muayenelerinin yap\u0131laca\u011f\u0131 noktalar\u0131 belirler. Belirledi\u011fi \u00f6l\u00e7\u00fcm noktalar\u0131ndan mekanik sistemin muayenesini ve \u00f6l\u00e7\u00fcm\u00fcn\u00fc talimata ve referans de\u011ferlere g\u00f6re yapar. Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinin talimata g\u00f6re bak\u0131mlar\u0131n\u0131 yapar. Gev\u015feklik, s\u0131z\u0131nt\u0131, ka\u00e7ak gibi durumlar\u0131n giderilmesini sa\u011flar. Enerji depolamal\u0131 sistemlerde, enerji depolama ekipman\u0131n\u0131n bak\u0131m\u0131n\u0131 talimata uygun olarak yapar. \u015eebeke ba\u011flant\u0131s\u0131z sistemlerde eviricinin ba\u015flama\/kapama i\u015flevlerini kontrol eder. \u015eebeke ba\u011flant\u0131l\u0131 sistemlerde eviricinin kesintide devreden \u00e7\u0131kma \u00f6zelli\u011fini kontrol eder. Kontrol ve \u00f6l\u00e7\u00fcm sonu\u00e7lar\u0131 kapsam\u0131nda yetkisi dahilinde de\u011fi\u015ftirtebilece\u011fi par\u00e7an\u0131n de\u011fi\u015ftirilmesini sa\u011flar. MOD\u00dcL 6 - 125","E.2.13 Yetkisi dahilinde olmayan durumlarda 33. Bak\u0131m alan\u0131 g\u00fcvenlik \u00f6nlemleri ve E.2.14 ilgili birimle irtibata ge\u00e7erek yap\u0131lacak uygulanmas\u0131 E.2.15 i\u015flem hakk\u0131nda bilgi al\u0131r. 34. Bak\u0131m \u00f6ncesi haz\u0131rl\u0131k i\u015flemleri 36. Yetkisi dahilinde yap\u0131lan par\u00e7a de\u011fi\u015fim Panellerin ve di\u011fer ekipmanlar\u0131n i\u015flemleri temizli\u011finin talimata uygun olarak 37. Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinin yap\u0131lmas\u0131n\u0131 sa\u011flar. g\u00f6rsel kontrolleri 38. Elektrik sisteminde bak\u0131m kapsam\u0131nda Panellerin k\u0131smi g\u00f6lgelenmeye neden olan yap\u0131lan \u00f6l\u00e7\u00fcmler \u00e7evresel etkilerinin giderilmesini sa\u011flar. 39. Mekanik sistemlerinde yap\u0131lacak \u00f6l\u00e7\u00fcmler ve muayeneler 40. Enerji depolama ekipman\u0131n bak\u0131m\u0131 41. Panellerin ve di\u011fer ekipmanlar\u0131n temizlik kontrolleri 14.2. Yeterlilik Kontrol Listesi-2 (Bak\u0131m S\u00fcrecini Sonland\u0131rmak) Ba\u015far\u0131m \u00f6l\u00e7\u00fctleri Mesleki Bilgiler ve Uygulama Becerileri Yap\u0131lan bak\u0131m, tespit edilen ar\u0131zalar ve E.3.1 ger\u00e7ekle\u015ftirilen uygulamalarla ilgili dok\u00fcmanlar\u0131 haz\u0131rlar. E.3.2 Kullan\u0131lan makine, ekipman ve g\u00fcvenlik E.3.3 malzemelerinin toplanmas\u0131n\u0131 sa\u011flar. E.3.4 \u00c7al\u0131\u015fma alan\u0131n\u0131n temizlenmesini sa\u011flar. Fotovoltaik g\u00fc\u00e7 sistemleri bile\u015fenlerinde bak\u0131m E.3.5 kapsam\u0131nda yetkisi dahilinde de\u011fi\u015fmesi gereken par\u00e7alar\u0131n de\u011fi\u015ftirilmesini sa\u011flar. Bak\u0131m yapt\u0131\u011f\u0131 alan\u0131n enerjisinin verilmesi i\u00e7in ilgili birime bilgi verir. MOD\u00dcL 6 - 126"]


Like this book? You can publish your book online for free in a few minutes!
Create your own flipbook